Anda di halaman 1dari 45

BST106-M10[CK] Weighing Controller

For: Auto Checkweigher


[Rejecting Mode & Weight Sorting Mode with 3-12 Sorts]

Operation Manual V3.0

Changsha Supmeter Technological Co.,Ltd.


Preface

Thank you very much for your purchase!


This manual covers safety precaution, technical specification, operation interface, installation&
connection, function&operation and so on. In order to make the product running at its best, please read this
manual in advance, and reserve it for the future reading.
The technology update, function enhancement and quality improvement may lead to some differences
between this manual and the physical product, please understand.
Without our authorization, the contents of this manual are not allowed to be copied and reproduced.
Main Features:
 Suitable for Auto Checkweigher. Optional Application Modes: Rejecting Mode
[Low/Normal/High] and Weight Sorting Mode with 3-12 Sorts].
 EMC design with high anti-jamming capability, suitable for industrial environment.
 Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.
 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
 Loadcell Interface
 Max. Connection Quantity: 8 Loadcells (350Ω).
 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal
resolution and sampling frequency 400Hz.
 Special anti-vibration digital filtering algorithm for ensuring the weighing stability and
accuracy when there is strong vibration on the load receptor, and the rapid response capability
when the weight signal changes.
 I/O Interface
 9 Normally open switch inputs [DI] and 16 normally open transistor switch outputs [DO].
 2 Definable analog signal AO[0~10V] for weight signal output or conveyor speed control.
 Digital Communication Interface
 COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
 COM[RS485] for connecting RS485 Serial Printer.
 USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data
to U-disk.
 Software Function
 Manual Screen-locking/Screen-unlocking, Auto Screen-locking, Digital Setting&Calibration
and I/O Testing functions available.
 Initial Zero Adjustment after Power-on, Auto Zero Tracking, Zero Fine Adjustment and Zero
Calibration functions available.
 Static Calibration and Dynamic Compensation functions available.
 Definable DI funtion of ‘Photo-electric Identification’ for identifing the unchecked product
entering the weigher.
 Optional Weight-checking Mode: Dynamic Mode and Static Mode.
 Optional 3-12 Sorting Areas with Batch Counting, Weight Totalizing and DO outputs.
 10 Formulas for weight-checking&sorting control.
 The Batch Records can be printed automatically.
 The Totalizing Reports and Formulas can be queried and printed.
 With the multitasking mode, the weighing&control process will not be interrupted by
parameter setting and the other operations.

1
Contents

1. SAFETY PRECAUTION .................................................................................................................4

2. TECHNICAL SPECIFICATION ....................................................................................................5

3. OPERATION INTERFACE ............................................................................................................7

3.1 OPERATION INTERFACE OF USER LOGIN ................................................................................................ 7

3.2 MAIN OPERATION INTERFACE ............................................................................................................... 8

3.3 BUTTON OPERATION ............................................................................................................................. 9

3.4 DATA DISPLAY & QUICK SETTING ....................................................................................................... 10

3.5 ALARM SIGN ....................................................................................................................................... 11


3.5.1 Alarm Message ...........................................................................................................................11
3.5.2 Prompt Message .........................................................................................................................11
3.5.3 Error Message.............................................................................................................................11

4. INSTALLATION&CONNECTION ..............................................................................................12

4.1 INSTALLATION ..................................................................................................................................... 12


4.1.1 Outline Size ............................................................................................................................... 12
4.1.2 Installation Angle ...................................................................................................................... 12
4.1.3 Installation Mode ....................................................................................................................... 13

4.2 TERMINAL ........................................................................................................................................... 14


4.2.1 Terminal Diagram ...................................................................................................................... 14
4.2.2 Power Supply Terminal ............................................................................................................. 14
4.2.3 Loadcell Terminal ...................................................................................................................... 15
4.2.4 Digital Communication Terminal .............................................................................................. 15
4.2.5 Analog&Switch Signal Terminal ............................................................................................... 16

4.3 EX-FACTORY DEFINITION OF DI/DO FUNCTION .................................................................................. 17

4.4 TYPLE APPLICATIONS .......................................................................................................................... 18


4.4.1 System Diagrams ....................................................................................................................... 18
4.4.1.1 System Diagram for Rejecting Mode............................................................................. 18
4.4.1.2 System Diagram for Weight Sorting Mode [3-12 Sorts] ................................................ 19
4.4.2 DI/DO Connection .................................................................................................................... 20

2
5. OPERATION PROCEDURE ........................................................................................................21

6. FUNCTION&OPERATION ..........................................................................................................22

6.1 MAIN MENU INTERFACE ..................................................................................................................... 22

6.2 MAIN MENU FUNCTION ...................................................................................................................... 23

6.3 F1 PARAMETER SETTING [F1 SET] ..................................................................................................... 24


6.3.1 Weighing Parameters [Scale] ..................................................................................................... 24
6.3.2 Calibration Parameters [Calibration] ......................................................................................... 26
6.3.3 Formula Parameters [Formula] .................................................................................................. 27
6.3.4 Working Mode Parameters [Mode] ........................................................................................... 28
6.3.5 Timer Parameters [Timer] ......................................................................................................... 30
6.3.6 Communication Parameters [Comm.] ....................................................................................... 31
6.3.7 Display Parameters [Display] .................................................................................................... 32

6.4 F2 SYSTEM CALIBRATION [F2 CAL] ................................................................................................... 33


6.4.1 Static Calibration [Static Cal.] ................................................................................................... 33
6.4.2 Dynamic Compensation [Dyn. CMP] ....................................................................................... 34

6.5 F9 I/O FUNCTION DEFINITION [F9 I/O] ............................................................................................... 35


6.5.1 DO Function Definition ............................................................................................................. 35
6.5.2 DI Function Definition .............................................................................................................. 35
6.5.3 AO Function Definition ............................................................................................................. 36

APPENDIX A. PRINT FORMATS ...................................................................................................37

APPENDIX B. REGISTER TABLE OF HOST-SLAVE MODBUS[ASCII/RTU] ........................39

APPENDIX C. DATA FRAME FORMAT OF CONTINUOUS SENDING [ASCII]....................43

3
1. Safety Precaution

 Lithium Battery Installation


A Lithium battery should be equipped in the product. If it is not allowed to be transported
together with the product because of embargo, please make a purchase according to the
model offered by us and install it by yourself.
 Application environment
Make sure that this product works under the environment where is accord with the technical
specifications.
Do not open the shell before power-off.
 Controller Protection
The product, as a low-voltage equipment, should be kept away from the high-voltage
equipments.
 Scale Frame Grounding Protection
For avoiding bodily injury from electric shock accident and separating the loadcells from
strong interference, the scale frame should be connected with the electronic scale grounding
net and the ground resistance should be less than 4Ω.
 Cable Laying
Weighing signal, analog signal and communication signal cables should be laid in pipes, and
do not lay them together with power cables.
 Power Supply
The power supply of the weighing controller should be separated from the power supply of
the driving devices.
Please make sure that the inputted voltage is correct before power-on.
If the voltage fluctuation exceeds the allowed range, please use a power stabilizer to get a
stable voltage supply.
 Environmental Protection
Before the Lithium battery equipped in the product being discarded, please insulate its
positive or negative pole, do not put it into fire.
Although the product is made of the lead-free components, after used in the industrial
environments, it’s possible to be polluted. So, while being discarded as worthless, the product
should be processed lawfully as leady industrial waste for environment protection.
 Other Notes
The installation, wiring and maintenance should be operated by the engineers with the
relevant professional knowledge and safety operation ability. Although being not described in
this manual, the relevant safety operating procedures and standards should be followed.

4
2. Technical Specification

 Executing Standard
 CMC GB/T 7724-2008《Electronic Weighing Meter》PRC National Standard.
 OMIL R76: 2006《Non-automatic Weighing Instruments》International Recommendation.
 Accuracy Grade: III.
 Number of Verification Intervals: 5,000.
 Static Weighing Accuracy: 0.2‰.

 Structure&Configuration
 7”/10.2” Ultralight and ultrathin TFT touch screen with embedded weighing/control module.
 Cortex-A8 CPU with 600MHz Clock, 128M RAM and 128M Flash.

 Display&Operation
 16-bit Color screen with 800×480[7”] or 1024×600[10.2”] pixel and LED backlight.
 Chinese/English graphical interface display and touch operation.
 Weight Display Range: -99,999~+999,999.
 Scale Capacity: Setting Range 1~999,999.
 Scale Division: Optional 1, 2, 5, 10, 20, 50.
 Display Resolution: 1/100,000.
 Weight Unit: Optional kg, t, g, none.
 Decimal Point: Optional 0, 0.0, 0.00, 0.000.

 Loadcell Interface
 Max. Connection Quantity: 8 Loadcells (350Ω).
 Excitation Voltage/Max. Current: DC5V, 120mA.
 Signal Input Range: 0~12.5mV.
 Output Sensitivity of Loadcell: 1.0~2.5mV/V.
 24-bit ∑-△ADC with internal resolution 1/1,000,000.
 Sampling Frequency: 400Hz.
 Special anti-vibration digital filtering algorithm.
 Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
 Gain Drift: ±5ppm/℃.
 Non-linearity: 0.005%FS.

 Switch&Analog Signal Interface


 9 Normally Open Switch Inputs [DI].
 16 Normally Open Transistor Switch Outputs [DO]: DC24V, 1A.
 2 Analog Signal Output [AO]: 0~10V/Max.50mA, Non-linearity: 0.05%FS.

 Digital Communication Interface


 COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
 COM[RS485] for connecting RS485 Serial Printer with Baud Rate ‘9600bps’, Parity Check ‘None’, 8

5
Data Bits and 1 Stop Bit.
 USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to
U-disk.

 Report Print
 The Batch Records can be printed automatically.
 The Totalizing Reports and Formulas can be queried and printed.

 Operating Specification
 Operating Voltage: DC24V±20%.
 Max. Power Consumption: 6W.
 7” Touch Screen
 Outline Size: 226.5×163×36mm [W×H×D].
 Window Size: 153.6×86.64mm [W×H].
 Panel Cut-out Size: 215×152mm [W×H].
 Weight: Approx. 0.72kg.
 10.2” Touch Screen
 Outline Size: 274×193×40mm [W×H×D].
 Window Size: 220.8×132.9mm [W×H].
 Panel Cut-out Size: 261×180mm [W×H].
 Weight: Approx. 1.2kg.
 Protection Level of Front Panel: IP65.
 Operating Temperature: -20℃ to +45℃.
 Storage Temperature: -30℃ to +60℃.
 Relative Humidity: Max. 85%RH.

6
3. Operation Interface

3.1 Operation Interface of User Login

The following ‘User Login Interface’ will be displayed after power-on.

Name Operation Note


User Login.
Exfactory Passwords:
Operation ‘Main Menu / F5 User / Password / PSW
【Login】  Operator: None.
Set’ for Modifying Password.
 Engineer: 0.
 Administrator: 1.
 Operator: User with lowest authorization.
After password inputted, the matching
【User Name】  Engineer: User with higher authorization.
User Name will be displayed.
 Administrator: User with highest authorization.
Operation ‘Main Menu / F5 User / Password / Login
【Enter】 Enter ‘Main Operation Interface’.
[Logoff]’ for Re-login and Logoff.

7
3.2 Main Operation Interface

Parameter [300] ‘Application Mode’= ‘0: Rejecting Mode [Low/Normal/High]’:

Parameter [300] ‘Application Mode’= ‘1: Weight Sorting Mode [3-12 Sorts]’:

8
3.3 Button Operation

Name Operation State Indicator Authorization

Start.

‘Stop’ state: Start the conveyors and enter the


【Start】
weight-checking running state.

‘Pause’ state: Recover Running.

【Stop】 Stop.

【Zero】 Zero Fine Adjustment [No Power-down Protection].

【Z.Rng】 ‘Non-load Zero Range’ Setting.

‘Sorting Area Quantity’ [3-12] Selection.


【Sort】
Used for Weight Sorting Mode.

【Form】 ‘Working Formula No.’ Selection.

【Alarm】 Alarm Query / Clear Alarm. Red: Alarm state. All Users

Report Print:

 [ Auto Print]: Print Batch Records.


【Print】
 [Total]: Print Totalizing Report.

 [Formula]: Print Present Working Formula.

Screen-locking: Locking/unlocking the operating


Blinking Red: Locked.
【Lock】 buttons of main display interface.
Grey: Unlocked.
Auto Screen-locking: Refer to parameter [901].

【Menu】 Enter Main Menu.

【En/Cn】 English/Chinese display switch.

【User】 User Login. Display: Operator / Engineer / Admin.

Clear Screen: Clear the display values of Checking Engineer


【Clear】
Weight, Batch Count and Totalized Weight. Administrator

9
3.4 Data Display & Quick Setting

Name Description Authorization

Biggest Digits Checking Weight of the present batch.

Bigger Digits Static/Dynamic Real-time Weight Value [Weight Unit].

[Z.RNG] Non-load Zero Range.

[TOTAL] Total Totalized Weight.

[T_PCS] Total Batch Count.

[REJ_P] Batch Count of Rejected Products.

[Dynamic Check] Dynamic Weight-checking Mode.

[Static Check] Static Weight-checking Mode.

[Weight Trigger] ‘Weight > Non-load Zero Range’ for triggering weight-checking process.

DI switch ‘Photo-electric Identification’ turned on and ‘Weight > Non-load


[PE_Switch ID]
Zero Range’ for triggering weight-checking process.

[RUN] Running state.

[CHECK] Weight-checking state.

[PAUSE] Conveyors pause after weight-checking.

[OV_LOAD] Overload Alarm.

[ZERO] Weight ≤ Non-load Zero Range.

[STAB] Weight is stable.

[PE_SW] DI switch ‘Photo-electric Identification’ turned on.

[CHECKED] Weigh-checking process of the present batch Ended.

[Date/Time] Date/Time.
Engineer
[Checking Speed] ‘Feeding&Checking Conveyors Speed’ setting.
Administrator
[Sorting Speed] ‘Sorting Conveyor Speed’ setting.

Formula Table ‘Formula Parameters’ setting.

[PCS] Batch Count.

10
3.5 Alarm Sign

3.5.1 Alarm Message

Message Alarm Cause Solution


Refer to parameter [303] ‘Pause for Rejected
Pause Alarm Pause for Rejected Products. Products’.
Press button ‘Start’ to recover running.

3.5.2 Prompt Message

Message Alarm Cause Solution


Refer to parameter [123] ‘Zero Fine Adjusting
ZERO Invalid Over ‘Zero Fine Adjusting Range’.
Range’.

3.5.3 Error Message

Message Alarm Cause Solution


RAM Fault The chip RAM is damaged. Replace the chip RAM.
EEPROM Fault The chip EEPROM is damaged. Replace the chip EEPROM.
Parameter Error The chip EEPROM is damaged. Replace the chip EEPROM.
Weighing Signal Weighing Signal reversed or not
Connect the loadcell correctly.
Error connected.
ADC Fault The chip ADC is damaged. Replace the ADC module.
1. Check if the loadcell is connected.
Weighing signal exceeds A/D
Over ADC Range 2. Check if the capacity of loadcell is too small.
conversion range.
3. Check if the loading weight is too big.
1 . Check if the set value of parameter [102]
‘Scale Capacity’ is reasonable.
Weight > (Scale Capacity + 9 ×
Overload Alarm 2. Check if the loadcell is connected.
Scale Division).
3. Check if the capacity of loadcell is too small.
4. Check if the loading weight is too big.
Internal Data-Bus
Please contact manufacturer.
Fault
System Fault Please contact manufacturer.

11
4. Installation&Connection

4.1 Installation

4.1.1 Outline Size

W1

H1
7”

Outline Size Panel Cut-out Size

Outline Size Front Panel Size Box Body Size Panel Cut-out Size
Product
W×H×D[mm] W×H[mm] W×H [mm] W1×H1[mm]
7” 226.5×163×36 226.5×163 213×150 215×152
10.2” 274×193×40 274×193 259×178 261×180

4.1.2 Installation Angle

The installation angle should be in the range of 0~30°.

12
4.1.3 Installation Mode

Before installation the front end of the screw should be flat with the edge of the hook.

13
4.2 Terminal

4.2.1 Terminal Diagram

14 12 8 7 5 1 12 10 8 5 1

P S+ S- E+ E- S+ S- P S+ S- E+ E- S+ S- A+ B- P T2 T1 G Rx Tx 16 15 14 13
LOADCELL COM2 PRG COM1 DO

24V DC
LAN

+ -

1
2
USB1

COM
USB2

AO DI DO
1+ 2+ G 1 2 3 4 5 6 7 8 9 V- 1 2 3 4 5 6 7 8 9 10 11 12 V+

1 4 12 1 14

4.2.2 Power Supply Terminal

No. Pin Description


DC24V DC24V[±20%] Power Input Port
1 - DC Input -.
2 + DC Input +.
For separating the weighing controller from the interference of the driving devices, the DC24V power supply of
the weighing controller should not be shared by the DI/DO.

14
4.2.3 Loadcell Terminal

No. Pin Description

LOADCELL Loadcell Port

1 S- Weighing Signal [mV] Input -.

2 S+ Weighing Signal [mV] Input +.

3 E- Excitation Voltage -.

4 E+ Excitation Voltage + [DC5V].

5 Unused.

6 Unused.

7 P Shield Ground.

8~14 Unused.

4.2.4 Digital Communication Terminal

No. Pin Description

COM1 RS232 Digital Communication Port [Definable]

5 Tx Transmit Data [TXD].

6 Rx Receive Data [RXD].

7 G Signal Ground / Shield Ground [GND].

PRG

8 T1
Special for manufacturer.
9 T2

COM2 RS485 Digital Communication Port [Definable]

10 P Shield Ground.

11 B- Data -.

12 A+ Data +.

COM RS485 Serial Printer Port

7 A+ Data +.

8 B- Data -.

USB1 USB Data Copying Port / HMI Software Download Port / Mouse Port

15
4.2.5 Analog&Switch Signal Terminal

Name Pin Description


AO 0~10V Analog Output Port [Definable]
1 AO1+ AO1 Output +.
2 AO2+ AO2 Output +.
3 G AO Output -.
DI Switch Signal Input Port [Valid with high-level input voltage 24V]
4 DI1 Switch Signal Input 1.
5 DI2 Switch Signal Input 2.
6 DI3 Switch Signal Input 3.
7 DI4 Switch Signal Input 4.
8 DI5 Switch Signal Input 5.
9 DI6 Switch Signal Input 6.
10 DI7 Switch Signal Input 7.
11 DI8 Switch Signal Input 8.
12 DI9 Switch Signal Input 9.

Name Pin Description


DO Transistor Switch Signal Output Port [Valid with high-level output voltage 24V]
1 V- DC24V Input -.
2 DO1 Normally Open Contact Output 1.
3 DO2 Normally Open Contact Output 2.
4 DO3 Normally Open Contact Output 3.
5 DO4 Normally Open Contact Output 4.
6 DO5 Normally Open Contact Output 5.
7 DO6 Normally Open Contact Output 6.
8 DO7 Normally Open Contact Output 7.
9 DO8 Normally Open Contact Output 8.
10 DO9 Normally Open Contact Output 9.
11 DO10 Normally Open Contact Output 10.
12 DO11 Normally Open Contact Output 11.
13 DO12 Normally Open Contact Output 12.
14 V+ DC24V Input +.

1 DO13 Normally Open Contact Output 13.


2 DO14 Normally Open Contact Output 14.
3 DO15 Normally Open Contact Output 15.
4 DO16 Normally Open Contact Output 16.
Contact Capacity of Transistor Switch: DC24V, 1A.

16
4.3 Ex-factory Definition of DI/DO Function

DI [Valid with high-level input voltage 24V]


No. Pin Signal Name Description
Start.
4 DI1 START
OFF→ON→OFF.
Stop.
5 DI2 STOP
OFF→ON→OFF.
6 DI3 CLA Clear Alarm.
Photo-electricIdentification [For identifing the
7 DI4 CHECK_ID unchecked product entering the weigher].
OFF→ON.
Clear Screen.
8 DI5 CLS
OFF→ON→OFF
9 DI6 Unused.
10 DI7 Unused.
Zero Fine Adjustment.
11 DI8 ZERO
OFF→ON.
12 DI9 Unused.

DO [Transistor, Valid with high-level output voltage 24V]


No. Pin Signal Name Description
1 V- V- DC24V Input -.
2 DO1 SORT1 [LO] Sorter1 Control.
3 DO2 SORT2 [NM] Sorter2 Control.
4 DO3 SORT3 [HI] Sorter3 Control.
5 DO4 SORT4 Sorter4 Control.
6 DO5 SORT5 Sorter5 Control.
7 DO6 SORT6 Sorter6 Control.
8 DO7 SORT7 Sorter7 Control.
9 DO8 SORT8 Sorter8 Control.
10 DO9 SORT9 Sorter9 Control.
11 DO10 SORT10 Sorter10 Control.
12 DO11 SORT11 Sorter11 Control.
13 DO12 SORT12 Sorter12 Control.
14 V+ V+ DC24V Input +.

1 DO13 CHECK_BELT Feeding&Checking Conveyors Control.


2 DO14 SORT_BELT Sorting Conveyor Control.
3 DO15 RUN Running State.
4 DO16 CHECKED Weight-checking process of the present batch Ended.

17
4.4 Typle Applications

4.4.1 System Diagrams

4.4.1.1 System Diagram for Rejecting Mode

Photo-electric Identification Switch [optional]

Unchecked Products Qualified Products


Sorter1&3

Feeding Conveyor Checking Conveyor Sorting Conveyor

Weigher

Loadcell
Rejected Products

Control Box

Weighing Controller

Refer to ‘6.3.4 Working Mode Parameters [Mode]’.

18
4.4.1.2 System Diagram for Weight Sorting Mode [3-12 Sorts]

Photo-electric Identification Switch [optional]

Unchecked Products Sorter1 Sorter2 。


。。 SorterN
Rejected

Feeding Conveyor Checking Conveyor Sorting Conveyor

Weigher

Loadcell Sort1 Sort2 。


。。 SortN

Control Box

Weighing Controller

Refer to ‘6.3.4 Working Mode Parameters [Mode]’.

19
4.4.2 DI/DO Connection

DI
START DI1 Push Button

STOP DI2 Push Button

Clear Alarm CLA DI3 Push Button

Photo-electric Identification CHECK_ID DI4 Photoelectric Switch

Clear Screen CLS DI5 Push Button

DI6 Push Button

DI7 Push Button

Zero Fine Adjustment ZERO DI8 Push Button

DI9
DO [Transistor]

V- V-

Sorter1 Control SORT1 [LO] DO1 Sorter1

SORT2 [NM] DO2

SORT3 [HI] DO3

SORT4 DO4

SORT5 DO5

SORT6 DO6 DC24V


SORT7 DO7 Power

SORT8 DO8

SORT9 DO9

SORT10 DO10

SORT11 DO11

Sorter12 Control SORT12 DO12 Sorter12


+
V+ V+

CHECK_BELT DO13 Feeding&Checking Conveyors

SORT_BELT DO14 Sorting Conveyor

Running State RUN DO15

DO16 Weight-checking process of the present batch Ended


CHECKED

20
5. Operation Procedure

Connection & Power on

Scale Setting

Zero Calibration

Static Calibration
Dynamic Compensation

Auto Zero Tracking Range &


Zero Fine Adjusting Range Setting

Working Mode Setting


Timer Setting

Formula Setting

Other Settings

Working Process Control

21
6. Function&Operation

6.1 Main Menu Interface

22
6.2 Main Menu Function

Main Menu Second Menu Description Authorization


Scale Scale parameters setting.
Calibration Calibration parameters setting.
Formula Working formula parameters setting.
F1 SET Mode Working mode parameters setting.
Timer Timer parameters setting.
Comm. Communication parameters setting.
Display Display and operation interface parameters setting. Engineer
Zero Calibration without loading on the weigher to correct Administrator
Zero Value.
1 Static Cal.
Load Caliration with loading standard weights on the weigher
F2 CAL to correct Span Coefficient.
Dynamic Compensation for correcting ‘Dynamic Span
2 Dyn. CMP Compensation Ratio’ and getting higher dynamic
weight-checking accuracy.
Real-time Real-time Data Query.
All Users [‘Clear’
Historical Batch Records Query / USB Copy [Excel Format] /
F3 DATA Batch Rec. only for Engineer
Clear.
& Administrator]
Hour Rec. Hour Records Query / USB Copy [Excel Format] / Clear.
Engineer
F4 CLS Clear all of the Historical Batch Records and Hour Records.
Administrator
Login/Password Set/Logoff. Exfactory Passwords:
Password All Users
Operator: None; Engineer: 0; Administrator: 1.
F5 USER
Fac. Code Factory Code.
Factory
Fac. Inf. Factory Information.
I/O Test I/O Test.
Reliability I/O Reliability Test.
Part-Default Reset partial parameters to default values.
F6 FAC All-Default Reset all parameters to default values. Administrator
AO Adjust AO Zero/Full Adjustment and AO Linearity Test.
Para. Backup Parameter Backup.
Para. Recover Parameter Recover.
F7 TIME Date&time Setting. Engineer
F8 FORM Formula management. Administrator
DI/DO/AO Function Definition.
F9 I/O DEF Administrator
‘Part-Default’ operation has no effect on I/O parameters.
MAIN Return to Main Display Interface. All Users

23
6.3 F1 Parameter Setting [F1 SET]

6.3.1 Weighing Parameters [Scale]

No. Sign Range Default Description REG


Weight Unit
0: None
100 Weight Unit 0~3 3 1: kg 40101
2: t
3: g
Decimal Point Position
0: 0
Decimal Point
101 0~3 1 1: 0.0 40103
Position
2: 0.00
3: 0.000
Scale Capacity
Max. allowed loading weight of the load
102 Scale Capacity 1~999999 10000 receptor. 40105
Scale Capacity≤Total Capacity of Loadcells –
Self-weight of Load Receptor.
Scale Division
0: 1
1: 2
103 Scale Division 1~50 1 2: 5 40107
3: 10
4: 20
5: 50
-20000~ 0 Zero Value
104 Zero Value 40109
+999999 [*] Only for query.
0.0001~ 1.0000 Span Coefficient
105 Span Coefficient 40111
999.9999 [*] Only for query.
Dyn. Span
0.5000 1.0000 Dyn. Span Compensation Ratio
106 Compensation 40113
~2.0000 [*] Only for query.
Ratio
107 Unused 0 Unused 40115

[*]: ‘Part-Default’ operation has no effect on the parameter.

24
No. Sign Range Default Description REG

Stablity Judging Range [d: Division]

Stablity Judging Weight Variance per [109] ‘Stablity Judging


108 0~5 0 40117
Range Time’ being in [108] ‘Stablity Judging Range’

means ‘Weight is stable’.

Stablity Judging
109 0.1~9.9 0.5 Stablity Judging Time [s] 40119
Time

Anti-Vibration Digital Filter1

Set Value Cutoff Frequency

00 None

01 11.2Hz

02 8.0Hz

Anti-Vibration 03 5.6Hz
110 0~9 3 40121
Digital Filter1 04 4.0Hz

05 2.8Hz

06 2.0Hz

07 1.4Hz

08 1.0Hz

09 0.7Hz

Smooth Digital Filter2

Smooth Digital Smooth Filtering Sample Number.


111 1~100 50 40123
Filter2 Further lower the cutoff frequency for more

stable weight display.

25
6.3.2 Calibration Parameters [Calibration]

No. Sign Range Default Description REG

Auto Zero Tracking Permission

0: OFF
Auto Zero
1: ON [Only when weight is stable, Auto
120 Tracking 0~1 0 40151
Zero Tracking will be allowed]
Permission
Refer to parameter [108] ‘Stablity Judging
Range’ and [109] ‘Stablity Judging Time’.

Auto Zero
121 1~10 1 Auto Zero Tracking Time [s] 40153
Tracking Time

Auto Zero Tracking Range [d: Division]

Auto Zero Zero Tracking Rate = [122] / [121].


122 0.1~50.0 0.2 40155
Tracking Range Suggestion: Zero Tracking Rate ≤ 0.5

[Division/s].

Zero Fine Adjusting Range

If Weight variation caused by Zero Value

Zero Fine changing is within this range, ‘Zero Fine


123 0~50000 50 40157
Adjusting Range Adjustment’ will be valid.

Suggestion: Set value ≤ (Scale Capacity ×

4%).

124 Unused 0 0 Unused 40159

Initial Zero Adjustment after Power-on


Initial Zero Adj.
125 0~1 0 0: OFF 40161
after Power-on
1: ON [without Power-down Protection]

Initial Zero
126 0~1800 30 Initial Zero Adjusting Time [s] 40163
Adjusting Time

Initial Zero Adjusting Range


Initial Zero
127 0~50000 50 Suggestion: Set value ≤ (Scale Capacity × 40165
Adjusting Range
20%).

26
6.3.3 Formula Parameters [Formula]

No. Sign Range Default Description REG

[300] Application = ‘1: Weight Sorting Mode’

200 Sort1 Min. Setpoint 0~60000 4949 Min. Weight Setpoint Value of Sort1 40201

201 Sort1 Max. Setpoint 0~60000 4949 Max. Weight Setpoint Value of Sort1 40203

202 Sort2 Min. Setpoint 0~60000 4950 Min. Weight Setpoint Value of Sort2 40205

203 Sort2 Max. Setpoint 0~60000 5050 Max. Weight Setpoint Value of Sort2 40207

204 Sort3 Min. Setpoint 0~60000 5051 Min. Weight Setpoint Value of Sort3 40209

205 Sort3 Max. Setpoint 0~60000 10000 Max. Weight Setpoint Value of Sort3 40211

206 Sort4 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort4 40213

207 Sort4 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort4 40215

208 Sort5 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort5 40217

209 Sort5 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort5 40219

210 Sort6 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort6 40221

211 Sort6 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort6 40223

212 Sort7 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort7 40225

213 Sort7 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort7 40227

214 Sort8 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort8 40229

215 Sort8 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort8 40231

216 Sort9 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort9 40233

217 Sort9 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort9 40235

218 Sort10 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort10 40237

219 Sort10 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort10 40239

220 Sort11 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort11 40241

221 Sort11 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort11 40243

222 Sort12 Min. Setpoint 0~60000 0 Min. Weight Setpoint Value of Sort12 40245

223 Sort12 Max. Setpoint 0~60000 0 Max. Weight Setpoint Value of Sort12 40247

[300] Application = ‘0: Rejecting Mode’

200 Target Weight Value 0~60000 5000 Target Weight Value 40271

201 Low Deviation 0~60000 50 Low Deviation Permission Value 40273

202 High Deviation 0~60000 50 High Deviation Permission Value 40275

27
6.3.4 Working Mode Parameters [Mode]

No. Sign Range Default Description REG

Application Mode

Application 0 0: Rejecting Mode [Low/Normal/High]


300 0~1 40301
Mode [*] 1: Weight Sorting Mode [3-12 Sorts]

Authorization: Administrator.

Weight-checking Mode

0: Dynamic Mode [Weight-check with all

conveyors running]
Weight-checking 0
301 0~1 1: Static Mode [Weight-check after the 40303
Mode [*]
feeding&checking conveyors stopped, but the

sorting conveyor keeps on running]

Authorization: Administrator.

Non-load Zero Range

Non-load Zero ‘Weight > Non-load Zero Range’ is used as the


302 1~60000 100 40305
Range necessary condition for triggering the

weight-checking process.

Delay Time Before Checking t1 [s]

 To Dynamic Weight-checking Mode:

Suggestion: t1=0.

t1 Delay Time  To Static Weight-checking Mode: Set this


303 0.00~9.99 0.00 40307
Before Checking parameter properly for ensuring the weight

of the unchecked product has already acted

fully on the weigher before the

weight-checking process starts.

Max. Weight-checking Time t2 [s]

t2 Max. Weight- Once ‘Gorss Weight≤Non-load Zero Range’ or


304 0.00~9.99 5.00 40309
checking Time ‘Weight-checking Time ≥ t2’, the weight-

checking process will end automatically.

[*]: ‘Part-Default’ operation has no effect on the parameter.

28
No. Sign Range Default Description REG

Conveyors Pause After Checking

0: Unpause [After weight-checking, all

conveyors will continue to run]

1: Pause; 2: Pause for Rejecting

[To Dynamic Weight-checking Mode: After


Pause After 0
305 0~2 weight-checking, all conveyors will stop] 40311
Checking [*]
[To Static Weight-checking Mode: After weight

-checking, the feeding&checking conveyors

will keep on stopping state, but the sorting

conveyor will not stop]

Authorization: Administrator.

Delay Time Before Conveyors Auto

Re-running t3 [s]

Only used for Static Weight-checking Mode.

Set value = 0: No ‘Auto Re-running’.


t3 Before Auto
306 0.00~9.99 2.00 Set value > 0: After the checked product being 40313
Re-running
unloaded from the weigher [Weight ≤

Non-load Zero Range] and then the time t3

delayed, the feeding&checking conveyors will

recover running automatically.

[*]: ‘Part-Default’ operation has no effect on the parameter.

29
6.3.5 Timer Parameters [Timer]

No. Sign Range Default Description REG

T1 Before Sorter1
400 0.00~99.99 0.00 Delay Time Before Sorter1 Starts T1 [s] 40401
Starts

T2 Before Sorter2
401 0.00~99.99 0.00 Delay Time Before Sorter2 Starts T2 [s] 40403
Starts

T3 Before Sorter3
402 0.00~99.99 0.00 Delay Time Before Sorter3 Starts T3 [s] 40405
Starts

T4 Before Sorter4
403 0.00~99.99 0.00 Delay Time Before Sorter4 Starts T4 [s] 40407
Starts

T5 Before Sorter5
404 0.00~99.99 0.00 Delay Time Before Sorter5 Starts T5 [s] 40409
Starts

T6 Before Sorter6
405 0.00~99.99 0.00 Delay Time Before Sorter6 Starts T6 [s] 40411
Starts

T7 Before Sorter7
406 0.00~99.99 0.00 Delay Time Before Sorter7 Starts T7 [s] 40413
Starts

T8 Before Sorter8
407 0.00~99.99 0.00 Delay Time Before Sorter8 Starts T8 [s] 40415
Starts

T9 Before Sorter9
408 0.00~99.99 0.00 Delay Time Before Sorter9 Starts T9 [s] 40417
Starts

T10 Before Sorter10


409 0.00~99.99 0.00 Delay Time Before Sorter10 Starts T10 [s] 40419
Starts

T11 Before Sorter11


410 0.00~99.99 0.00 Delay Time Before Sorter11 Starts T11 [s] 40421
Starts

T12 Before Sorter12


411 0.00~99.99 0.00 Delay Time Before Sorter12 Starts T12 [s] 40423
Starts

T13 Sorter Running


412 0.00~99.99 0.50 Sorter Running Hold Time T13 [s] 40425
Hold Time

30
6.3.6 Communication Parameters [Comm.]

No. Sign Range Default Description REG


Communication
800 0~99 1 Communication Address 40801
Address
COM1[RS232]/COM2[RS485] Baud Rate
801 COM1 Baud Rate 40803
0 0: 9600bps
0~2
0 1: 19200bps
802 COM2 Baud Rate 40805
2: 115200bps
COM1 Parity COM1/COM2 Parity Check
803 40807
Check 0 0. None
0~2
COM2 Parity 0 1. Even
804 40809
Check 2. Odd
COM1 Comm. COM1/COM2 Communication Mode 40811
805 0
Mode 0: Host-salve Modbus[ASCII]
0~2
COM2 Comm. 1: Host-salve Modbus[RTU]
806 0
Mode 2: Continuous Sending[ASCII] 40813
Data for Continuous Sending Mode
0: Unused
1: Weight
Continuous
807 0~5 1 2: Unused 40815
Sending
3: Checking Weight
4: Total Totalized Weight
5: Total Batch Count
Continuous Sending Frequency [Hz]
0: 1Hz; 1: 2Hz; 2: 5Hz; 3: 10Hz
4: 20Hz; 5: 25Hz; 6: 50Hz; 7: 100Hz
Continuous Note
808 0~7 2 40817
Sending Frequency Baud Rate Max. Sending Frequency
9600 bps 50Hz
19200 bps 100Hz
115200 bps 100Hz
COM1/COM2 Modbus Data Format
Reading&Writing Order of 4-Byte Registers:
COM1 Modbus 0: H4 H3 L2 L1
809 40819
Data Format 1: H3 H4 L1 L2
0~3 0 2: L1 L2 H3 H4
COM2 Modbus 3: L2 L1 H4 H3
810 40821
Data Format The HEX byte order of float and long int
registers in the weighing controller is ‘H4 H3
L2 L1’.

31
6.3.7 Display Parameters [Display]

No. Sign Range Default Description REG

Date Format

0 0: YYYY-MM-DD [Year-Month-Day]
900 Date Format 0~2 40901
[*] 1: MM-DD-YYYY [Month-Day-Year]

2: DD-MM-YYYY [Day-Month-Year]

Auto Screen-locking

0: OFF
Auto
901 0~1 0 1: ON [The operating buttons of main 40903
Screen-locking
display interface will be locked automatically if

there is not any button operation in one minute]

902 Exfactory Date [*] Exfactory Date

903 Serial No. [*] Product Serial No.

WTM Version Weighing Software Version No.


904 [*]
No. CK-WXXXXXX-VX.X

HMI Software Version No.


905 HMI Version No. [*]
CK-HXXXXXX-VX.X

0 Display Style
906 Display Style 0
[*] 0: CFY

[*]: ‘Part-Default’ operation has no effect on the parameter.

32
6.4 F2 System Calibration [F2 CAL]

6.4.1 Static Calibration [Static Cal.]

Operation Steps:
 Step1: Zero Calibration. Let the weigher at unloading and static state and after the weight display value
being stable, press the button【Zero Cal.】to display and save the new ‘Zero Value’. If the new Zero Value
is not in its allowed range, the operation【Zero Cal.】will be invalid.
 Step2: Load Calibration. Load standard weights on the weigher with ‘Loading weight ≥ [50% × Scale
Capacity]’. After the weight display value being stable, press the button【Load Cal.】, then input
‘Calibrating Weight’ value and save the new ‘Span Coefficient’ valu. If the loading weight is too small
[AD Value ≤ Zero Value], the operation【Load Cal.】will be invalid.

Sign Data Sign Data


Big Digits Static Real-time Weight Value [Weight Unit]
Zero Value The saved ‘Zero Value’ Span Coeff The saved ‘Span Coefficient’ value
Zero Variation = AD Value – Zero Calibrating Weight = Weight of
Zero Var Cal. Weight
Value Standard Weights
Motion Weight is dynamic changing.
AD Value Real-time AD Value of weighing signal
Stable Weight is stable.

33
6.4.2 Dynamic Compensation [Dyn. CMP]

Operation Steps:
 Step1: Static Weighing. Load a sample of unchecked product on the weigher. After Weight Display
Value being stable, press the button【Stat. Weigh】to get the static weight value of the sample.
 Step2: Dynamic Compensation. Take the sample away from the weigher, press the button【Dyn. CMP】
and input ‘Dynmatic Weight-checking Times’, then the conveyors will start automatically and enter the
process of ‘Dynamic Compensation’.
 Step3: Weigh the sample dynamically on the weigher. After the dynmatic weight-checking times
reached to its set value, the conveyors will stop and the process of ‘Dynamic Compensation’ will end
automatically, then display and save the new ‘Dynamic Span Compensation Ratio’. If the new
‘Dynamic Compensation Ratio’ is not in its allowed range, the operation【Dyn. CMP】will be invalid.

Sign Data Sign Data


Big Digits Uncompensated Real-time Weight Value [Weight Unit]
The saved ‘Dynamic Span
Static Weight Static Weight of the unchecked product Span CMP
Compensation Ratio’ value
Uncompensated Dynamic Checking
AD Value Real-time AD Value of weighing signal Dyn. Weight
Weight
Motion Weight is dynamic changing.
Total Weight Dynamic Totalized Weight
Stable Weight is stable.
Button【Stop】: Exit from the process of ‘Dynamic Compensation’.

34
6.5 F9 I/O Function Definition [F9 I/O]

6.5.1 DO Function Definition

No. Sign Range Default Description REG


DO Function Options
0: None
700 DO1 1 40701
1: Sorter1 Control
701 DO2 2 40703
2: Sorter2 Control
702 DO3 3 40705
3: Sorter3 Control
703 DO4 4 40707
4: Sorter4 Control
704 DO5 5 40709
5: Sorter5 Control
705 DO6 6 40711
6: Sorter6 Control
706 DO7 7 40713
7: Sorter7 Control
707 DO8 8 40715
0~16 8: Sorter8 Control
708 DO9 9 40717
9: Sorter9 Control
709 DO10 10 40719
10: Sorter10 Control
710 DO11 11 40721
11: Sorter11 Control
711 DO12 12 40723
12: Sorter12 Control
712 DO13 13 40725
13: Feeding&Checking Conveyors Control
713 DO14 14 40727
14: Sorting Conveyor Control
714 DO15 15 40729
15: Running State
715 DO16 16 40731
16: Weight-checking Ended
17~60: Unused

6.5.2 DI Function Definition

No. Sign Range Default Description REG


DI Function Options
0: None
716 DI1 1 40733
1: Start
717 DI2 2 40735
2: Stop
718 DI3 3 40737
3: Clear Alarm
719 DI4 4 40739
4: Photo-electric Identification [For identifing the
720 DI5 0~9 5 40741
unchecked product entering the weigher]
721 DI6 6 40743
5: Clear Screen
722 DI7 7 40745
6: Print
723 DI8 8 40747
7: Unused
724 DI9 9 40749
8: Zero Fine Adjustment
9~60: Unused

35
6.5.3 AO Function Definition

No. Sign Range Default Description REG


AO1 Signal
0: Unused
1: Weight
725 AO1 Signal 0~4 4 40751
2: Unused
3: Checking Weight
4:Feeding&Checking Conveyors Speed Control
AO1
726 0.00~10.00 0.00 AO1 Low Limit Value [V] 40753
Low Limit Value
AO1 High Limit
727 0.00~10.00 5.00 AO1 High Limit Value [V] 40755
Value
Max. Weight Value for AO1 Output
AO1
728 1~999999 10000 Weight≥[728]: AO1=High Limit. 40757
Max. Weight
Weight≤0: AO1=Low Limit.
Max. Speed Value for AO1 Output [m/min]
AO1
729 5.0~999.9 100.0 Checking Speed≥[729]: AO1=High Limit. 40759
Max. Speed
Checking Speed=0: AO1=Low Limit.
AO2 Signal
0: Unused
1: Weight
730 AO2 Signal 0~4 4 40761
2: Unused
3: Checking Weight
4: Sorting Conveyor Speed Control
AO2
731 0.00~10.00 0.00 AO2 Low Limit Value [V] 40763
Low Limit Value
AO2
732 0.00~10.00 5.00 AO2 High Limit Value [V] 40765
High Limit Value
Max. Weight Value for AO2 Output
AO2
733 1~999999 10000 Weight≥[733]: AO2=High Limit. 40767
Max. Weight
Weight≤0: AO2=Low Limit.
Max. Speed Value for AO2 Output [m/min]
AO2
734 5.0~999.9 100.0 Sorting Speed≥[734]: AO2=High Limit. 40769
Max. Speed
Sorting Speed=0: AO2=Low Limit.
Checking Speed Running Speed of Feeding&Checking
735 5.0~100.0 30.0 40771
[AO1] Conveyors [m/min]
Sorting Speed
736 5.0~100.0 30.0 Running Speed of Sorting Conveyor [m/min] 40773
[AO2]

36
Appendix A. Print Formats

 Table 1. Batch Records

BATCH RECORDS
------------------------
2016-01-29 10:51:10 Starting Time of Auto-printing
------------------------
P1: 499.9g Batch No. Checking Value
P2: 500.1g
P3: 499.8g
P4: 500.2g
… …
------------------------
2016-01-29 10:51:30 End Time of Auto-printing

 Table 2. Totalizing Report for Rejecting Mode

TOTAL REPORT
------------------------
TOTAL: 2000.0g Total Totalized Weight
T_PCS: 4 Total Batch Count
NM_TOT: 2000.0g Totalized Weight of Sort2 [Normal]
NM_PCS: 4 Batch Count of Sort2 [Normal]
LO_TOT: 0.0g Totalized Weight of Sort1 [Low]
LO_PCS: 0 Batch Count of of Sort1 [Low]
HI_TOT: 0.0kg Totalized Weight of Sort3 [High]
HI_PCS: 0 Batch Count of Sort3 [High]
------------------------
2016-01-29 10:52:30

 Table 3. Formula for Rejecting Mode

FORMULA
------------------------
FORM: #01 Formula No.
SET_P: 500.0g Target Weight Value
L_DEV: 5.0g Low Deviation Permission Value
H_DEV: 5.0g High Deviation Permission Value
------------------------
2016-01-29 10:53:30

37
 Table 4. Totalizing Report for Weight Sorting Mode

TOTAL REPORT
------------------------
TOTAL: 2000.0g Total Totalized Weight
T_PCS: 4 Total Batch Count
S1_TOT: 0.0g Totalized Weight of Sort1
S1_PCS: 0 Batch Count of Sort1
S2_TOT: 2000.0g Totalized Weight of Sort2
S2_PCS: 4 Batch Count of Sort2
S3_TOT: 0.0kg Totalized Weight of Sort3
S3_PCS: 0 Batch Count of Sort3
… … …
… … …
S12_TOT: 0.0g Totalized Weight of Sort12
S12_PCS: 0 Batch Count of Sort12
REJ_TOT: 0.0g Totalized Weight of Rejected Products
REJ_PCS: 0 Batch Count of Rejected Products
------------------------
2016-01-29 10:54:30

 Table 5. Formula for Weight Sorting Mode

FORMULA
------------------------
FORM: #01 Formula No.
S1_MIN: 0.0g Min. Weight Setpoint Value of Sort1
S1_MAX: 494.9g Max. Weight Setpoint Value of Sort1
S2_MIN: 495.0g Min. Weight Setpoint Value of Sort2
S2_MAX: 505.0g Max. Weight Setpoint Value of Sort2
S3_MIN: 505.1g Min. Weight Setpoint Value of Sort3
… … …
S12_MIN: 0.0g Min. Weight Setpoint Value of Sort12
S12_MAX: 0.0g Max. Weight Setpoint Value of Sort12
------------------------
2016-01-29 10:55:30

38
Appendix B. Register Table of Host-Slave MODBUS[ASCII/RTU]

Command
Data Name Type Address Attribute Description
[HEX]
Sorting Quantity Long 40197 R/W 03/10 3~12
Working Formula No. Long 40199 R/W 03/10 1~10
Auto Printing 0: OFF
Long 40399 R/W 03/10
Permission 1: ON
Zero Calibration Long 41101 W 10 0xA1: Zero Calibration
Load Calibration Long 41103 W 10 0xA5: Load Calibration
Calibrating Weight Long 41105 W 10 Used for Load Calibration
Long 41109 W 10 Special for manufacturer
Long 41111 W 10 Special for manufacturer
Long 41201 R 03 Unused
Weight Long 41203 R 03
Working Formula No. Long 41205 R 03 1~10
Total Totalized Weight Long 41207 R 03
Total Batch Count Long 41209 R 03
41211
Bit0 1: RAM Fault
Bit1 1: EEPROM Fault
Bit2 1: Parameter Error
Bit3 1: Signal Error
Bit4 1: ADC Fault.
Bit5 1: Over ADC Range
Bit6 1: Overload Alarm
Bit7
Alarm State Long Bit8 R 03
Bit9 1: Pause
Bit10
Bit11
Bit12
Bit13
Bit14
Bit15
Bit16
Bit17 1: ZERO Invalid
Checking Weight Long 41213 R 03

39
Command
Data Name Type Address Attribute Description
[HEX]
41215
Bit0 1: Overload Alarm
Bit1
Bit2 0: Unused. 1: Unused
Bit3 1: Non-load Zero Range
Bit4 1: Weight Value is stable
0: Dynamic Weight-checking
Mode
Bit5
1: Static Weight-checking
Mode
Running State Long R 03 1: DI Function of
Bit6 ‘Photo-electric Identification’
Defined
1: DI switch ‘Photo-electric
Bit7
Identification’ turned on
Bit8 1: Weight-checking Ended
Bit9 1: Pause
Bit10 1: Running
Bit11 1: Weight-checking
Bit12
Bit13 1: Screen Locked
Non-load Zero Range Long 41217 R 03
Checking Speed Long 41219 R/W 03/10
Sorting Speed Long 41221 R/W 03/10
Long 41223 R 03 Unused
Long 41225 R 03 Unused
Long 41227 R 03 Unused
Batch Count of
Long 41229 R 03
Rejected Products
Sort1 Batch Count Long 41231 R 03
Sort2 Batch Count Long 41233 R 03
Sort3 Batch Count Long 41235 R 03
Sort4 Batch Count Long 41237 R 03
Sort5 Batch Count Long 41239 R 03
Sort6 Batch Count Long 41241 R 03
Sort7 Batch Count Long 41243 R 03
Sort8 Batch Count Long 41245 R 03
Sort9 Batch Count Long 41247 R 03
Sort10 Batch Count Long 41249 R 03
Sort11 Batch Count Long 41251 R 03
Sort12 Batch Count Long 41253 R 03

40
Command
Data Name Type Address Attribute Description
[HEX]
Sort1 Totalized Weight Long 41255 R 03
Sort2 Totalized Weight Long 41257 R 03
Sort3 Totalized Weight Long 41259 R 03
Sort4 Totalized Weight Long 41261 R 03
Sort5 Totalized Weight Long 41263 R 03
Sort6 Totalized Weight Long 41265 R 03
Sort7 Totalized Weight Long 41267 R 03
Sort8 Totalized Weight Long 41269 R 03
Sort9 Totalized Weight Long 41271 R 03
Sort10 Totalized Weight Long 41273 R 03
Sort11 Totalized Weight Long 41275 R 03
Sort12 Totalized Weight Long 41277 R 03
Totalized Weight of
Long 41279 R 03
Rejected Products
Long 41401 W 10 Unused
0x55: Start
Start/Stop Control Long 41403 W 10
0x5C: Stop
Long 41405 W 10 Unused
0x45: Clear Alarm
Function Operation 1 Long 41407 W 10 0x55: Unused
0x56: Unused
0xA1: Zero Fine Adjustment
Function Operation 2 Long 41409 W 10 0xA2: Unused
0xA3: Clear Screen
Long 41411 W 10 Unused
Long 41413 W 10 Unused
Long 41415 W 10 Unused
Long 41417 W 10 Unused
Long 41419 W 10 Unused
0xFF:
Recover Running Long 41421 W 10 ‘Pause’ state:
Recover Running

Long: Signed Long Int.

41
Register Table of Formulas

[300] Application = ‘1: Weight Sorting Mode’


Formula No. / Register Address
Parameter
1 2 3 4 5 6 7 8 9 10
Sort1 Min. Setpoint 42001 42101 42201 42301 42401 42501 42601 42701 42801 42901
Sort1 Max. Setpoint 42003 42103 42203 42303 42403 42503 42603 42703 42803 42903
Sort2 Min. Setpoint 42005 42105 42205 42305 42405 42505 42605 42705 42805 42905
Sort2 Max. Setpoint 42007 42107 42207 42307 42407 42507 42607 42707 42807 42907
Sort3 Min. Setpoint 42009 42109 42209 42309 42409 42509 42609 42709 42809 42909
Sort3 Max. Setpoint 42011 42111 42211 42311 42411 42511 42611 42711 42811 42911
Sort4 Min. Setpoint 42013 42113 42213 42313 42413 42513 42613 42713 42813 42913
Sort4 Max. Setpoint 42015 42115 42215 42315 42415 42515 42615 42715 42815 42915
Sort5 Min. Setpoint 42017 42117 42217 42317 42417 42517 42617 42717 42817 42917
Sort5 Max. Setpoint 42019 42119 42219 42319 42419 42519 42619 42719 42819 42919
Sort6 Min. Setpoint 42021 42121 42221 42321 42421 42521 42621 42721 42821 42921
Sort6 Max. Setpoint 42023 42123 42223 42323 42423 42523 42623 42723 42823 42923
Sort7 Min. Setpoint 42025 42125 42225 42325 42425 42525 42625 42725 42825 42925
Sort7 Max. Setpoint 42027 42127 42227 42327 42427 42527 42627 42727 42827 42927
Sort8 Min. Setpoint 42029 42129 42229 42329 42429 42529 42629 42729 42829 42929
Sort8 Max. Setpoint 42031 42131 42231 42331 42431 42531 42631 42731 42831 42931
Sort9 Min. Setpoint 42033 42133 42233 42333 42433 42533 42633 42733 42833 42933
Sort9 Max. Setpoint 42035 42135 42235 42335 42435 42535 42635 42735 42835 42935
Sort10 Min. Setpoint 42037 42137 42237 42337 42437 42537 42637 42737 42837 42937
Sort10 Max. Setpoint 42039 42139 42239 42339 42439 42539 42639 42739 42839 42939
Sort11 Min. Setpoint 42041 42141 42241 42341 42441 42541 42641 42741 42841 42941
Sort11 Max. Setpoint 42043 42143 42243 42343 42443 42543 42643 42743 42843 42943
Sort12 Min. Setpoint 42045 42145 42245 42345 42445 42545 42645 42745 42845 42945
Sort12 Max. Setpoint 42047 42147 42247 42347 42447 42547 42647 42747 42847 42947

[300] Application = ‘0: Rejecting Mode’


Formula No. / Register Address
Parameter
1 2 3 4 5 6 7 8 9 10
Target Weight Value 42071 42171 42271 42371 42471 42571 42671 42771 42871 42971
Low Deviation 42073 42173 42273 42373 42473 42573 42673 42773 42873 42973
High Deviation 42075 42175 42275 42375 42475 42575 42675 42775 42875 42975

42
Appendix C. Data Frame Format of Continuous Sending [ASCII]

Field Name Code HEX Description Example

START [Byte1] = 3D 3D [=]

O 4F Overload
Weighing State
S 53 Stable 53 [S]
[Byte2]
M 4D Motion

G 47 Unused

N 4E Weight
Data Name
B 42 Final Feeding Weight 4E [N]
[Byte3]
T 54 Total Totalized Weight

P 50 Total Batch Count


Data
+/- 2B/2D Plus/Minus Sign 2B [+]
[11 Bytes]
Value 30~39 0~9 30 [0]

[7 Bytes] 2E Decimal Point ‘.’ 30 [0]

31 [1]

Data Unit: 32 [2]

[Byte4~12] (Space) 20 Space: None 33 [3]

k 6B k: kg 2E [.]

t 74 34 [4]

g 67 67 [g]

[+00123.4g]

SUM [Byte13] 1 Byte XX SUM=Byte1+Byte2+…+Byte12 XX

END <CR> 0D 0D <CR>

[Byte14~15] <LF> 0A 0A <LF>

43
CMC00000028 CPC13/041728

Changsha Supmeter Technological Co.,Ltd.


Address: Building A6, Lugu International Industrial Park,
Changsha, 410205, China
Tel: +86 731 85115100
Fax: +86 731 85158100
Website: www.supmeter.com
E-mail: supmeter@supmeter.com

Anda mungkin juga menyukai