Anda di halaman 1dari 2284

Bills of Quantities

AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

PROJECT SUMMARY / DIVISION WISE

MAIN GUEST MOTHER


ITEM DESCRIPTION AMOUNT REMARKS DEWANIAH VILLA VIILA

No. (SR) B01 B02 B03

0.00
SUMMARY OF WORKS

1 DIVISION 01: GENERAL REQUIREMENTS - - - -


2 DIVISION 02: SITE WORK - - - -
3 DIVISION 03: CONCRETE - - - -
4 DIVISION 04: MASONRY - - - -
5 DIVISION 05: METALS - - - -
6 DIVISION 06: WOOD AND PLASTIC - - - -
7 DIVISION 07: THERMAL AND MOIST. PROTECTION - - - -
8 DIVISION 08: DOORS AND WINDOWS - - - -
9 DIVISION 09: FINISHES - - - -
10 DIVISION 10: SPECIALITIES - - - -
11 DIVISION 11: EQUIPMENT - - - -
12 DIVISION 12: FURNISHINGS - - - -
13 DIVISION 13: SPECIAL CONSTRUCTIONS - - - -
14 DIVISION 14: CONVEYING SYSTEMS - - - -
15 DIVISION 15: MECHANICAL - - - -
16 DIVISION 16: ELECTRICAL - - - -

431100001.xlsx/Summary Div/07/26/2019 QS/Baig 1/2284


MAIN GUEST MOTHER
ITEM DESCRIPTION AMOUNT REMARKS DEWANIAH VILLA VIILA

No. (SR) B01 B02 B03

0.00
*** OVER-LOOKED
NOTE:
Contractor should considered whatever mentioned in
the Drawings and BOQ as part of the contract
documents including compulsory notes etc.

PROJECT TOTAL COST - Saudi Riyal

431100001.xlsx/Summary Div/07/26/2019 QS/Baig 2/2284


1xDUPLEX MAJID & MAJID &
ABDULL CLUB ADEL MOHAMME IBRAHIM & DRIVERS SECURITY
VILLA NASER NASER
AZIZ HOUSE VILLA D VILLA ABD ILLAH DIWANIAH SITTING SITTING
(2xTYP. ) VILLA DIWANIAH

B04 B05 A&B B06 B07 B08 B09 B10 B11 B12 B13 B14

- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -

431100001.xlsx/Summary Div/07/26/2019 QS/Baig 3/2284


1xDUPLEX MAJID & MAJID &
ABDULL CLUB ADEL MOHAMME IBRAHIM & DRIVERS SECURITY
VILLA NASER NASER
AZIZ HOUSE VILLA D VILLA ABD ILLAH DIWANIAH SITTING SITTING
(2xTYP. ) VILLA DIWANIAH

B04 B05 A&B B06 B07 B08 B09 B10 B11 B12 B13 B14

431100001.xlsx/Summary Div/07/26/2019 QS/Baig 4/2284


MAIN CIVIL
U/G PUMP FENCE U/G PUMPS &
FENCE MAIN
U/G MAIN ROOM & secoundry ROOM
Carpark MAIN GATE EL ROOM-A EL ROOM-B W/TANK SWIMMING LANDSCAP FENCE
SURGE GATES (WATER
BUILDINGS POOL
TANK BUILDINGS FEATURE) E &
CARPARK

B14P B15 B16 B17 B18 B19 B 20 B22 B23 B24 B25

- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -
- - - - - - - - - - -

431100001.xlsx/Summary Div/07/26/2019 QS/Baig 5/2284


MAIN CIVIL
U/G PUMP FENCE U/G PUMPS &
FENCE MAIN
U/G MAIN ROOM & secoundry ROOM
Carpark MAIN GATE EL ROOM-A EL ROOM-B W/TANK SWIMMING LANDSCAP FENCE
SURGE GATES (WATER
BUILDINGS POOL
TANK BUILDINGS FEATURE) E &
CARPARK

B14P B15 B16 B17 B18 B19 B 20 B22 B23 B24 B25

431100001.xlsx/Summary Div/07/26/2019 QS/Baig 6/2284


OTHER

REMARKS

431100001.xlsx/Summary Div/07/26/2019 QS/Baig 7/2284


OTHER

REMARKS

431100001.xlsx/Summary Div/07/26/2019 QS/Baig 8/2284


Bills of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
PROJECT SUMMARY / BUILDING WISE

ITEM DESCRIPTION / SCOPE OF WORK AMOUNT REMARKS


No. Code Building Name (SR)
0.00

1 B01 MAIN DEWANIAH -


2 B02 GUEST VILLA -
3 B03 MOTHER VIILA -
4 B04 ABDULL AZIZ -
5 B05 1xDUPLEX VILLA (2xTYP. ) -
6 B06 CLUB HOUSE -
7 B07 MAJID & NASER VILLA -
8 B08 MAJID & NASER DIWANIAH -
9 B09 ADEL VILLA -
10 B10 MOHAMMED VILLA -
11 B11 IBRAHIM & ABD ILLAH -
12 B12 DIWANIAH -
13 B13 Service Building 1 -
14 B14 Service Building 2 -
15 B14P CAR PARK -
16 B15 MAIN GATE -
17 B16 Electrical substation 1 -
18 B17 Electrical substation 2 -
19 B18 U/G MAIN W/TANK -
20 B19 U/G PUMP ROOM & SURGE TANK -
21 B20 Secondary GATE -
22 B22 U/G PUMPS ROOM (MAIN WATER FEATURE) -
23 B23 SWIMMING
MAIN CIVIL POOL
& -
24 B24 LANDSCAPE -
25 B25 FENCE -
*** OVER-LOOKED
NOTE:
Contractor should considered whatever mentioned in the
Drawings and BOQ is part of the contract documents
including compulsory notes etc.

PROJECT - Saudi Riyal


TOTAL COST

431100001.xlsx/Summary Bldg./07/26/2019 QS/Baig 9/2284


Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

GENERAL NOTES

A The word "Contractor" herein shall mean "Tenderer" during Tendering Period.

B These General Requirements are applicable for the whole of the works, whether Architectural,
Structural, Electro-Mechanical, and External Works.

C Items included in these General Requirements are listed under different headings for reference purpose
only even if they relate to different documents in the Contract.

D If the Contractor wishes to price any of the items contained herein then each such item, clause, or sub-
clause must be individually priced. The Contractor shall not enter any lump sums covering more than
one or all items, clauses and sub-clauses.

E Monthly payments for General Requirements shall only be made for those costs which have been
properly incurred and for which the Contractor has inserted prices against in this Bill No. 1. Payment
for all time related items will only start from the date of the Engineer’s approval for the particular items
in this Bill No. 1.

F The Contractor is requested to check the number of pages in all Tender Documents and make sure that
nothing is missing. In case of any missing pages or parts of documents, the Contractor shall notify the
Engineer in writing during tendering period for rectification. No claim shall be entertained in the event
the Contractor's failure to do so.

CONDITIONS OF CONTRACT

Insurances

G The Contractor shall provide and maintain Insurances as stipulated in the Conditions of Contract.

Performance Guarantee

H The Contractor shall be required to furnish a Performance Guarantee as stipulated in the Conditions of
Contract.

To Collection SR

GRE-Building-Riyadh 3/2/10 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

CONDITIONS OF CONTRACT (CONT'D)

Other Obligations

A The Contractor shall comply in all respects with the Conditions of Contract and shall describe, list
below and price any obligation for which he has not allowed elsewhere and wishes to price separately:-

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

…………………………………………………………………………….

To Collection SR

GRE-Building-Riyadh 3/2/11 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

SPECIFICATIONS

General

A The Contractor shall comply with the requirements and obligations contained in the Specifications and
in particular the requirements of Division 1 as follows:-
01010 Summary of Work
01015 Contractor's Use of Site
01050 Field Engineering
01060 Regulatory Requirements
01100 Management and Administration Procedures
01300 Submittals
01400 Quality Requirements
01500 Temporary Facilities and Temporary Controls
Temporary Sheds
Storage Facilities
Hardstandings
Roads and Accesses
Electrical Power for the Works
Water for the Works
First Aid Facilities
Contractor's Site Offices
Office Accommodation and Equipment for the Engineer
Site Notice Board
Temporary Fencing and Hoarding
Progress Cleaning
Progress Cleaning
Maintain HSE standard
Contract closeout
Operation and maintenance data
Warranties

To Collection SR

GRE-Building-Riyadh 3/2/12 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

A Owner Representative Office:


a. no more than 75 m2 office comprising:
- one office for admistration
- one office for cosultant team leader
-one office for counsultant engineers (4) .
- one conference room for 8 persons.
- one toilet completely fitted.
- one kitchenette fully equipped with gas range and 11ft capacity fridge.

b. Furniture comprising desks, chairs, filing cabinets and open shelves, drawing racks.
c. Supply of adequate stationary for the Engineer’s Team as required .
d. Photocopying machine complete with automatic feeder, A3/A4 reduce/enlarge, sorter,
multicopy, maintenance service, spare parts and consumable products.
e. Facsimile machine.
f. Internet Connection DSL
g. Telephone Line
h. adequat Desktop Computer ( Wind 8 , withe Aut cad and latest Ms Office software +
printers , scaners , copier Extra...
i.Plotter machine A0 with scanner

To Collection SR

GRE-Building-Riyadh 3/2/13 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description
A

01600 Product Requirements


01700 Execution Requirements

Mock-ups, Tests, Shop and As-Built Drawings

B The Contractor shall allow to prepare and submit all necessary mock-ups, tests, shop and as-built
drawings called for in the specifications and in any other document to the approval of the Engineer.

BILLS OF QUANTITIES

Description Generally

A The descriptions included in the Bills of Quantities to describe the workmanship and materials
necessary for each item are not necessarily complete. The Contractor should refer to the Specifications,
Schedules and the Drawing for further information concerning the works and no claim or variation will
be considered on account of his failure to acquaint himself with such information.

Measurements Generally

B All quantities contained in the Bills of Quantities are intended to give reasonable indications of the
works shown on the Drawings.

C All quantities shall be re-measured on site as executed and approved by the Engineer.

D Unless otherwise stated, all works have been measured net as fixed in its place with no allowance made
for laps or waste, working space, bulking, shrinkage and the like and irrespective of any local customs.

E Generally, in setting down dimensions in the Bills of Quantities, the sequence is length-width-height.
All measurements have been taken up or down to the nearest meter (or other units), and where exactly
half meter (or other units) measurements result, these have been taken up.

F The quantities in the Bills of Quantities shall not be used as a basis for ordering materials and the
Contractor is entirely responsible for assessing the quantities of materials to be ordered.

Provisional Quantities

GRE-Building-Riyadh 3/2/14 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

G Where quantities are indicated to be "Provisional" they shall be re-measured in accordance with the
Principle of Measurement rules and Pricing and Measurement Preambles. The actual quantities shall be
paid to the Contractor at the rates inserted by him in the Bills of Quantities and the Contract Price shall
be adjusted accordingly.

To Collection SR

GRE-Building-Riyadh 3/2/15 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

BILLS OF QUANTITIES (CONT'D)

Method of Measurement
A The Bills of Quantities have been prepared in accordance with the Principles of Measurement
(International) for Works of Construction, June 1979 (POMI) as published by the Royal Institution of
Chartered surveyors and as amended in the Pricing and Measurement Preambles set out in this
document. The Contractor is deemed to have interpreted the intent of this document and understood all
the nuances to enable each and every item included in the Bills of Quantities to be fully and correctly
priced, since no claim will be entertained in the event of misinterpretation.

B Where there is a divergence between the Principles of Measurement and the Pricing and Measurement
Preambles, the Pricing and Measurement Preambles shall take precedence.

C Executed works shall be measured on site using the above mentioned Principles of Measurement and as
amended in the Pricing and Measurement Preambles included in this document.

Pricing Generally

D The Contractor shall satisfy himself as to the meaning of every item in the Bills of Quantities and the
rates and prices inserted by him will be deemed to cover all his obligations under the Contract
(Specifications, Drawings, Conditions of Contract, any Addenda, and other contract documents) and all
matters and things necessary for the proper construction, completion and maintenance of the works
including (but not by way of limitation), for all temporary work required (including any that may be
required by Sub-Contractors, whether nominated or otherwise).

E The price shall include for all materials and labour, storage and handling transportation, samples,
testing coordination and for the provision and use of all plant, whether mechanical or non-mechanical,
required for carrying out of the works, in their proper sequence, for shifting, altering and adapting such
temporary work and plant as may be required the progress of the works.

To Collection SR

GRE-Building-Riyadh 3/2/16 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

BILLS OF QUANTITIES (CONT'D)

Pricing Generally (Cont'd)

A The price shall include for removing at completion and making good any surfaces disturbed.

B The price shall include for the Guarantees and bonds required; for the costs of preparing a tender; and
the final account; and for overheads and profit, full customs and import duties temporary services and
for all other establishment charges and on costs of whatever nature. No claim for additional payment
will be allowed for any error or misunderstanding by the Contractor in these respects.

C The Contractor shall submit with his offer a detailed breakdown of all his rates.

D The Contractor should price all items he considers of value. If any item is not priced by the Contractor,
it shall be deemed to be executed by the Contractor but it has no value or the value of such item, clause
or sub-clause is spread-out in the rates for other items elsewhere in the Bills of Quantities.

E The Contractor shall complete the Collections at the end of each Division or Bill, and Summaries at the
end of each Bill and carry the totals to the General Summary. Total of the General Summary shall be
carried out to the Form of Tender.

Provisional Sums

F Provisional Sums will be dealt with in the manner set forth in the General and Particular Conditions of
Contract.

G The Provisional Sums included in the Bills of Quantities may be expended totally, in part or not at all as
the Engineer may direct and the Contract price shall be adjusted accordingly.

To Collection SR

GRE-Building-Riyadh 3/2/17 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description
BILLS OF QUANTITIES (CONT'D)

Dayworks

A Any work instructed by the Engineer which cannot be valued by the application of the contract rates
will be valued on a Daywork basis in accordance with the Schedule of Dayworks attached at the end of
this document. Before commencement of any work to be executed on a Daywork basis the Contractor
shall inform the Engineer. Should work temporarily cease for any reason then the Contractor shall
inform the Engineer of the cessation and again when work re-commences. Records of materials used
and number of hours spent by labour, plant and machinery expended in the daywork are to be handed to
the Engineer for verification and signature no later than the end of the first day of the week following
the week in which the work was executed. Hours of supervisory staff will not be considered as
daywork unless they are actually working with their hands.

GENERAL OBLIGATIONS

Adjacent Properties

B If at any time the Contractor requires access to, over or under any land or properties for the execution
of the Works and which are not owned by the Employer, then the Contractor must obtain written
permission from the Owners and/or Occupiers of such land or properties. The Contractor shall be
responsible for undertaking all negotiations with Owners and/or Occupiers of adjacent land or
properties to obtain such written permission for, but which is not limited to, access for personnel, plant,
jibs of cranes, scaffolding or other temporary works, safety reasons or any other legitimate reason
where access is required by the Contractor for the due and proper completion of the Works.

C Further the Contractor shall be responsible for the payment of all fees or charges which may be payable
as a result of obtaining permission to gain access to adjacent land or properties and shall settle all fees
and charges entirely at his own expense. The Contractor shall keep the Employer fully informed of his
progress in obtaining permission(s) at all times, but the Employer will not accept any responsibility or
claims for payment in the event that the Contractor is unable to obtain the permission(s) he requires.

To Collection SR

GRE-Building-Riyadh 3/2/18 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description
GENERAL OBLIGATIONS (CONT'D)

Adjacent Properties (Cont'd)

A The Contractor shall take all reasonable precautions to prevent damage to adjoining property and any
damage caused shall be repaired to the satisfaction of the Employer and Owner of the property at the
Contractor's own expense.

B The Contractor shall advise Owners and Occupants of adjoining properties of the dates and if possible
the time and the duration of any work to be executed which may affect them.

Encroachment on Surrounding Land or Properties

C Uninterrupted continuous unimpeded access shall be maintained along all temporary roads adjacent to
the Site at all times and the Contractor must under no circumstances whatsoever use road footpaths for
the storage of materials, waste, debris or any item connected with the Site.

Checking Existing Levels and Property Lines

D The Contractor shall be responsible for checking any existing levels and property lines shown on
drawings before starting works.

Setting Out

E The Engineer will provide reference points for the Contractor from which he is to set out the Works.
The Engineer will check the setting out of the Works for which the Contractor shall give the Engineer
48 hours clear notice. The checking of the setting out by the Engineer in no way relieves the Contractor
of his responsibility for the accuracy of the setting out and any errors which may subsequently be found
remain the responsibility of the Contractor. Setting out shall be taken to mean the establishment of both
lines and levels.

F The Contractor shall protect the reference points throughout the duration of the Contract and shall make
no amendment to them unless the change is approved in writing by the Engineer.

To Collection SR

GRE-Building-Riyadh 3/2/19 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description
GENERAL OBLIGATIONS (CONT'D)

Setting Out (Cont'd)

A In the event that a reference point is disturbed or needs to be relocated to permit construction work to
proceed, then the Contractor shall inform the Engineer immediately as soon as the problem is known
and submit his proposals for repair and/or relocation. The Engineer will either accept or modify the
proposals or issue alternative instructions.

Accuracy

B The Works are to be set out and constructed in accordance with the tolerances given in BS 5606:1990.

C In the event that the Contractor does not achieve the required level of accuracy he is to inform the
Engineer and provide proposals as to how the inaccuracy may be remedied. The Engineer does not bind
himself to accept any proposals for remedying the inaccuracy and may instruct the Contractor to
remove the work installed and replace it achieving the accuracy required, but in any case the cost of all
remedying and/or replacement shall be borne by the Contractor.

Working Hours

D Normal working hours for the Site shall generally be from 7:30 a.m. to 5:30 p.m. Saturdays to
Thursdays inclusive and/or as allowed by the Local Authorities, no work is to be undertaken outside
these hours, on Fridays or during holidays without the Contractor requesting and the Engineer granting
permission. In the event that the Contractor deems it necessary to work overtime then the Engineer
reserves the right to seek reimbursement of any supervision or attendance required.

Records

E During the progress of the Works the Contractor shall keep at his own cost records of all details and
dimensions of the Works as constructed and shall at any time submit such records to the Engineer as
may be required.

To Collection SR

GRE-Building-Riyadh 3/2/20 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

GENERAL OBLIGATIONS (CONT'D)

Assistance to the Engineer

A The Contractor shall provide such labour and materials as the Engineer may require to assist him in
carrying out tests and checks on materials and workmanship and setting out and measurements of the
Works. Safety helmets, boots and measuring tapes shall be selected by the Engineer and supplied by the
Contractor to the Engineer and all his staff

Coordination with Authorities

B The Contractor shall allow to coordinate, pay fees and follow up with the corresponding Ministries and
Local Authorities, regarding connections of utilities, connections to infrastructure, access roads,
temporary fencing, site notice boards, and shall report all these matters to the Engineer.

C The Contractor shall allow for giving access to workmen employed by the Local Authorities and
providing them with attendance as required

Reports

D The Contractor shall submit daily reports, weekly reports, monthly reports, and any other reports as
required in the Conditions of Contract and in the Specifications.

Copyright and Advertising

E Unless the Employer gives his express permission in writing the Contractor:-

a) Accepts and understands that all documents generated for the purpose of this Contract are
protected by the laws of Copyright and must under no circumstances be used for any reason other
than for the purposes of this Contract.

b) Is not permitted to use photographs, drawings, paintings, sketches, models or any other copy of
the Works for advertising purposes, brochures and the like.

To Collection SR

GRE-Building-Riyadh 3/2/21 09/26/2007


Revision E
Mohamed Harasani Architects
GENERAL REQUIREMENTS FOR BOQ

Item Description

COLLECTION

Page No. 1/1

Page No. 1/2

Page No. 1/3

Page No. 1/4

Page No. 1/5

Page No. 1/6

Page No. 1/7

Page No. 1/8

Page No. 1/9

Page No. 1/10

Page No. 1/11

0
GENERAL REQUIREMENTS FOR BOQ

Total Carried to General Summary SR

GRE-Building-Riyadh 3/2/22 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/23 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/24 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/25 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/26 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

GRE-Building-Riyadh 3/2/27 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/28 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/29 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/30 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/31 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/32 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/33 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

GRE-Building-Riyadh 3/2/34 09/26/2007


Revision E
Mohamed Harasani Architects
REQUIREMENTS FOR BOQ

Amount
SR

Nil

Nil

Nil

Nil

Nil

Nil

Nil

Nil

Nil

Nil

Nil

Nil

GRE-Building-Riyadh 3/2/35 09/26/2007


Revision E
DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

1.10 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.10 see seprate BOQ for Div # 1 ( general requirments for BOQ LS 0 0 0

DIV#1 Total cost of this section Carried Forward To Summary - - -

2.00 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

2.30 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 8757 0 12524 0 4366 0 3472
0 0 0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0 0 0
each, complete

0 0 0
2.3.2 Up to levels and around & above foundations. m3 7126 0 6862 0 1991 0 584
0 0 0
Crushed aggregate base course, compacted to 100%
0 0 0
modified AASHTO density CBR ≥ 80%
0 0 0
2.3.3 250mm thick under slabs on grade m2 667 0 1188 0 507 0 477
0 0 0
2.40 ANTI TERMITE 0 0 0
Refer to spesification # 2285 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 36/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
2.4.1 Termite control treatment for all vertical and L.S 1 0 1 0 1 0 1
horizontal areas complete in accordance with 0 0 0
specifications. 0
0
0
DIV#2 Total cost of this section Carried Forward To Summary - - -

3.00 DIV#3 CONCRETE WORKS

Plain concrete (grade 15), 15N/mm2 at 28 days cylinder


compressive strength, using portland cement, including all
3.10 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 34 0 41 0 27 0 30

3.1.2 Blinding, 50mm thick under slabs on grade m3 28 0 69 0 26 0 22

3.1.4 Blinding, 50mm thick under all types of tie beams m3 4 0 7 0 2 0 5


0 0 0
Cyclopean concrete; comprising of 50:50 plain concrete 0 0 0
and stone
0 0 0
3.1.5 Pedestals under tie beams; size 500x500x500mm m3 5 0 10 0 2 0 4
0 0 0
Reinforced cast in situ concrete (grade 30), 30N/mm2
,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.20 including high tensile steel reinforcement grade 420Mpa 0 0 0 0
and mild steel reinforcement grade 280Mpa (Φ8mm); to

0 0 0

3.2.1 Foundations; (single, compound ) m3 66 0 128 0 61 0 85


0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 37/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

3.2.1.1 Foundations; (Raft , continous ) 62 0 92 0 58 0 43

0 0 0
3.2.2 Tie beams - Intermediate m3 72 0 66 0 0 0 0
0 0 0
3.2.3 Upper tie beams m3 72 0 66 0 47 0 32
0 0 0
3.2.4 Slabs on grade m3 106 0 268 0 97 0 85
0 0 0
3.2.5 Walls below slab on grade m3 209 0 170 0 58 0 63
0 0 0
3.2.6 Columns Below slab on grade m3 62 0 38 0 25 0 12
0 0 0
3.2.7 Water Tanks Slabs and Walls m3 169 0 119 0 85 0 95
0 0 0
3.2.8 Swimming pool Slabs and Walls m3 0 0 0 0 0 0 0
0 0 0
3.2.9 Car Park Roof Slab m3 0 0 0
0 0 0
0 0 0
Reinforced cast in situ concrete (grade 30), 30N/mm2
,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.30 and mild steel reinforcement grade 280Mpa (Φ8mm); to 0 0 0 0 0 0 0

0 0 0
3.3.1 Columns above slab on grade m3 136 0 107 0 119 0 232
0 0 0
3.3.2 Shear Walls , free standing walls above slab on Grade m3 103 0 157 0 96 0 73
0 0 0
3.3.3 Suspended solid slabs; including drop beams m3 353 0 485 0 76 0 224
0 0 0
Ribbed slabs;including hollow concrete blocks and hidden
3.3.4 beams -Ribs m2 0 0 934 0 1123 0 473

0 0 0
3.3.5 Stairs (steps, flights and landing) m3 8 0 11 0 19 0 12
0 0 0
3.3.6 Beams m3 52 0 43 0 7 0 11
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 38/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
3.40 CONCRETE PROTECTION AND INSULATION 0 0 0 0 0 0 0

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers; 0 0 0
1.5 liters/m2
Supply, install and test of the liquid applied polyurethane
waterproofing; applied in two layers; 1.5 liters/m 2 0 0 0

0 0 0
3.4.1 To all structural elements below grade m2 1366 0 1882 0 938 0 953
0 0 0
4mm thick torch applied SBS modified bituminous
polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and 0 0 0
specifications

0 0 0
3.4.2 To basement's walls - Vertical m2 1511 0 1464 0 559 0 490
3.4.2.1 Below slab on grade for basements -Horizontal 531 0 1341 0 486 0 419
3.4.2.2 Water Tanks 606 0 395 0 336 0 433
3.4.2.3 Swimming pools 0 0 0 0 0 0 0
0 0 0
PVC water stop, web thickness (4-5) mm, complete as
detailed on drawings and as specified 0 0 0

0 0 0
3.4.5 To water tanks; 250mm wide mr 27 0 27 0 27 0 27
0 0 0

DIV#3 Total cost of this section Carried Forward To Summary - - -

4.00 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and


internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 39/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.10 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2 326 0 737 0 613 0 403
and one layer of 150 mm concrete masoNo.y units 0 0 0
for external wall including reinforcement and 50 0 0 0
mm polyurethane foam insulation as specified in 0 0 0
the drawings & specifications:- 0 0 0
0 0 0
4.20 CMU walls Without Isolation 0 0 0
0 0 0
4.2.1 350 mm thick (CMU) block masoNo.y works to m2 0 67 0 6 0
internal / partition walls 0 0 0
0 0 0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 271 0 613 0 5 0 335
internal / partition walls / Parapet 0 0 0
0 0 0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0 252 0 55 0 137
internal / partition walls / Parapet 0 0 0
0 0 0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 479 0 1082 0 195 0 591
internal / partition walls / Parapet 0 0 0
0 0 0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 72 0 163 0 439 0 89
internal / partition walLS 0 0 0
0 0 0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 409 0 923 0 1042 0 504
internal /partition walLS 0 0 0
0 0 0
4.30 Forming of Arch. Shape 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 40/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
4.3.1 Construction of block masonry works, to get m3 0 21 0 0 11
shape as per architectural design . 0 0 0
0 0 0
DIV#4 Total cost of this section Carried Forward To Summary - - -

5.10 DIV#5 METAL WORKS LS 0 0 0


NA

DIV#5 Total cost of this section Carried Forward To Summary - - -

6.10 DIV#6 WOOD & PLASTIC LS - 0 0


NA

DIV#6 Total cost of this section Carried Forward To Summary - - -

7.10 DIV#7 THERMAL & MOISTURE

7.10 Waterproofing

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 41/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 562 0 827 0 416 0 343
moisture protection and waterproofing consisting 0 0 0
of 40 mm smooth finish sloping screed over roof 0 0 0
slab, 3+3 modified bituminous waterproofing 0 0 0
membrane over primer, including 50mm thick 0 0 0
extruded polystyrene boards 35KG/m3, separation 0 0 0
layer 140KG/m2 and finish tiles 300x300x30mm to 0 0 0
horizontal and vertical areas as shown and 0 0 0
specified in the drawings and specifications. 0 0 0
0 0 0
7.1.2 Ditto, but without roof boards along parapet LM 363 0 436 0 230 0 190
vertical up-stand 150 mm above from roof finish 0 0 0
level, including aluminum flashing 100 mm wide 0 0 0
and 1.5 mm thick at termination level as specified 0 0 0
in the drawings and specifications. 0 0 0
0 0 0
Wet Areas (Bath Rooms & Kitchens) 0 0 0
0 0 0
7.1.3 Supply, install and test of the liquid applied m2 60 0 91 0 159 0 74
polyurethane waterproofing type (black P.U.) to be 0 0 0
applied in two (2) layers 1.5 liters/m2 over the 0 0 0
entire flat areas including vertical and horizontal 0 0 0
penetrations, drains and to be self-terminated at 0 0 0
minimum 100 mm above the floor finish level 0 0 0
including separation layer, screed protection (or) 0 0 0
equivalent and all necessary components to 0 0 0
complete ready facility as specified. 0 0 0
0 0 0
Planter Boxes & Green area 0 0 0
Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 42/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4 0 0 0
Swimming Pool & Water Tanks 0 0 0
0 0 0
7.1.3 Supply, install and test of the liquid applied m2 157 0 154 0 154 0 154

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 43/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Cement based proofing 0 0 0
applied in two (2) layers 1.5 liters/m2 over the 0 0 0
entire areas including vertical and horizontal 0 0 0
penetrations, drains and to be self-terminated 0 0 0
equivalent and all necessary components to 0 0 0
complete ready facility as specified. 0 0 0

DIV#7 Total cost of this section Carried Forward To Summary - - -

8.10 DIV#8 DOORS & WINDOWS

Supply and installation of complete doors &


windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.10 Basement Floor


Excluded- At this stage

8.20 Ground Floor


Excluded- At this stage

8.50 First Floor


Excluded- At this stage

8.60 Penthouses
Excluded- At this stage

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 44/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

DIV#8 ALUMINUM & GLAZING INCLUDING WINDOWS SHUTTERS


(separate price from main windows units)

Supply and installation of electric motor operated windows


roller shutters (unless otherwise noted), complete with all its
necessary accessories to complete ready to operate facility
with as specified in the drawings and windows schedule, as
follows:

8.70 Windows Type / Main Dewaniah B-01:


Excluded- At this stage

8.80 Windows Type / Guest Villa B-02:


Excluded- At this stage

8.90 Windows Type / Mother Villa B-03:


Excluded- At this stage

8.10 Windows Type / Abdulaziz Villa B-04:


Excluded- At this stage

8.11 Windows Type / Abdulaziz Douplex B-05:


Excluded- At this stage

8.12 Windows Type / Club House B-06:


Excluded- At this stage
8.13 Windows Type / Majid & Nasir Villa B-07:
Excluded- At this stage

8.14 Windows Type / Majid & Nasir Diwaniah B-08:


Excluded- At this stage

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 45/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
8.15 Windows Type / Adel Villa B-09:
Excluded- At this stage

8.16 Windows Type / Mohammed Villa B-10:


Excluded- At this stage

8.17 Windows Type / Abdulillah & Ibrahim Villa B-11:


Excluded- At this stage

8.18 Windows Type / Diewaniah Ibrahim B-12:


Excluded- At this stage

DIV#8 Total cost of this section Carried Forward To Summary - - -

9.10 DIV#9 FINISHES

Plastering Works

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 1248 0 2178 0 1071 0 1190


0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 46/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
9.1.2 Plastering to walls internal sides. m2 2347 0 4075 0 2994 0 2225
0 0 0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 316 0 607 0 416 0 331
(Painted spaces only) 0 0 0
0 0 0
9.20 Ceilings Finishes 0 0 0
0 0 0
Supply and installation of ceiling finishing with 0 0 0
all the necessary materials and components as 0 0 0
indicated in the drawings and specifications:- 0 0 0
0 0 0
Inside the building 0 0 0
0 0 0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 400 0 400 0 400 0 400
R.C slab. (color as to be approved by the client 0 0 0
or client site representative) To store and stairs . 0 0 0
0 0 0
9.2.2 Paint on Concrete m2 100 0 100 0 100 0 100
0 0 0
0 0 0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 100 0 100 0 100 0 100
0 0 0
9.2.12 Moisture resistant gypsum board with paint for wet area m2 100 0 100 0 100 0 100
0 0 0
0 0 0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 50 0 50 0 50 0 50
Kitchens 0 0 0
0 0 0
Outside the building 0 0 0
Excluded- At this stage 0 0 0
9.2.15 EF09 WOOD TRELLIS

Wall Finishes 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 47/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Excluded- At this stage 0 0 0
0 0 0
9.30 External Walls Surfaces 0 0 0
Excluded- At this stage 0 0 0
0 0 0
GRC Panels 0 0 0
Excluded- At this stage 0 0 0
0 0 0
9.40 Internal Walls Surfaces 0 0 0
0 0 0
9.4.1 Paint the interior walls m2 400 0 400 0 400 0 400
0 0 0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 200 0 200 0 200 0 200
only for Maids bathrooms 0 0 0

0 0 0
9.50 Glass Walls 0 0 0
Excluded- At this stage 0 0 0
0 0 0
9.60 Floor Finishes 0 0 0
0 0 0
Supply and installation of floor finishing with 0 0 0
skirting and all the necessary materials and 0 0 0
components as indicated in the drawings and 0 0 0
specifications:- 0 0 0
Only for Maids , stores 50 0 50 0 50 0 50
9.6.1 VITRIFIED PORCELAIN TILES (300*300*8)mm m2 50 0 50 0 50 0 50
0 0 0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 50 0 50 0 50 0 50
(300*300*8)mm 0 0 0
0 0 0
0 0 0
9.6.16 100 mm Concrete with epoxy paint layer m2 50 0 50 0 50 0 50

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 48/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
9.70 Stairs Finishes 0 0 0
Only for service staires 0 0 0
Saudi Binanco Granite - THREAD 30mm 0 0 0
THICK)/RISER 20MM THICK price to include 0 0 0
grooves for non-slip material and nose forming as 0 0 0
follows: 0 0 0
0 0 0
9.7.1 for Service Staircase L.M 0 0 60 0 0 0 60
0 0 0

9.7.19 Main Entrance 0 0 0


Excluded- At this stage

DIV#9 Total cost of this section Carried Forward To Summary - - -

10.10 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is
incoporated in related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage

10.20 Toilet Accessories


Excluded- At this stage

10.30 MISCELLANEOUS

Stair & The Balconies and Windows Handrail

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 49/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

External Balconies
Excluded- At this stage

Internal Stair

10.3.3 Handrail to external stairs


Excluded- At this stage
10.3.4 Handrail to internal stairs LM 0 0 22 0 0 0 22
for service stair cases 0 0 0

Ladder 0 0 0
0 0 0
10.3.5 Internal metal ladder Radius 1 meter and 0.93 width 0 0 0

to connect between laundry /iron and maids lobby


0 0 0
complete with paint finish

0 0 0
10.3.6 PVC COATED STEEL LADDER RUNGS for water tanks No. 1 0 1 0 1 0 1
To suit water tank - HIGHT 3.3 : 3.72 0 0 0
0 0 0
Manhole Covers 0 0 0
0 0 0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 1 0 1 0 1 0 1
for water tanks - stone excluded on;y cover 0 0 0

Master Key System 0 0 0


Excluded- At this stage

DIV#10 Total cost of this section Carried Forward To Summary - - -

11.10 DIV#11 EQUIPMENTS 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 50/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
NA

DIV#11 Total cost of this section Carried Forward To Summary - - -

12.10 DIV#12 FURNITURE 0 0 0


NA

DIV#12 Total cost of this section Carried Forward To Summary - - -

13.10 DIV#13 SPECIAL CONSTRUCTIONS

13.10 Sky Light


Excluded- At this stage

13.20 Fountains Works


Excluded- At this stage

13.30 SWIMMING POOL FINISH


Excluded- At this stage

13.40 SAFETY HANDRAIL PANELS


Excluded- At this stage

DIV#13 Total cost of this section Carried Forward To Summary - - -

14.10 DIV#14 CONVEYING SYSTEM

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 51/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

14.10 LIFT / Private House & Dumpwaiter


Excluded- At this stage

DIV#14 Total cost of this section Carried Forward To Summary - - -

15.10 DIV#15 DIVISION 15 - MECHANICAL

15.10 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes 0
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 251 0 291 0 295 0 280
0 0 0
15.1.1.2 25 mm outside diameter pipe LM 38 0 67 0 86 0 34
0 0 0
15.1.1.3 32 mm outside diameter pipe LM 155 0 50 0 201 0 200
0 0 0
15.1.1.4 40 mm outside diameter pipe LM 37 0 174 0 7 0 12
0 0 0
15.1.1.5 50 mm outside diameter pipe LM 67 0 44 0 35 0 21
0 0 0
15.1.1.7 80 mm outside diameter pipe LM 5 0 5 0 5 0 6
0 0 0
Isolation Valves 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 52/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0 0 0
complete with all accessories and fittings, all as
specified as shown drawings.
0 0 0
Gate Valve 0 0 0
15.1.1.14 Gate vlave Ø 25 mm no 2 0 1 0 0 0 1
15.1.1.15 Gate vlave Ø 32 mm no 6 0 4 0 14 0 14
15.1.1.16 Gate vlave Ø 40 mm no 2 0 10 0 1 0 1
15.1.1.17 Gate vlave Ø 50 mm no 4 0 4 0 4 0 4
15.1.1.18 Gate vlave Ø 90 mm no 2 0 2 0 2 0 2
0 0 0
Concealed Valve 0 0 0
15.1.1.19 Concealed valve Ø 25 mm no 2 0 1 0 0 0 1
15.1.1.20 Concealed valve Ø 32 mm no 6 0 8 0 14 0 14
15.1.1.21 Concealed valve Ø 40 mm no 2 0 1 0 1 0 1
0 0 0
15.1.2 Electric Water Heaters 0 0 0 0 0 0 0
0 0 0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
0 0 0
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings ."by Saudi
Ceramic or equivalent as per owner instructions"

0 0 0
15.1.2.2 EWH-2 (50 Liter) No. 10 0 15 0 10 0 6
0 0 0
15.1.2.3 EWH-3 (80 Liter ) No. 2 0 6 0 6 0 11
0 0 0
15.1.2.4 EWH-4 (100 Liter) No. 0 0 3 0 0 0 0
0 0 0
15.1.3 Domestic Cold water tank 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 53/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0 0 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0 0 0
15.1.3.1 WT- ( 8000 L ) No. 1 0 1 0 1 0 1
0 0 0
15.1.4 Ground Water Tank Accessories 0 0 0 0 0 0 0
0 0 0
Level control float switches with electric connections,
15.1.4.4 complete with but not limited to over flow alarm bell LM 2 0 2 0 2 0 2
and all necessary works

0 0 0
Bronze equilibrium ball float valve, installed connected
15.1.4.5 and tested complete with accessories as specified as LM 1 0 1 0 1 0 1
shown on drawings.

0 0 0
15.1.4.6 Vent. 65 mm diameter. No. 1 0 1 0 1 0 1
0 0 0
15.1.5 Pumps 0 0 0 0 0 0 0
0 0 0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0 0 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0 0 0
ancillary work as specified nd as shown on
drawings."Grundfos ,KSB , Aurora or equivalent as per
owner instructions"

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 1 0 1 0 1 0 1
0 0 0
15.1.6 Domestic Water Booster Set 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 54/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating valves PN 16, lug and , strainer PN
16, flexible connections, concrete inertia pad, house
pad, vibration eliminator pad, low level control float
switches, pressure switch dry run protection and 0 0 0
controls all supplied from pump manufacturer
diaphragm tank (s), food quality synthetic rubber
membrane, steel painted body, working pressure 10
bars with isolating valve and pressure gauge, electric
connections, wiring and accessories all as specified and
shown on the drawings. "Grundfos ,KSB , Aurora or
equivalent as per owner instructions"

0 0 0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0 0 0 0 0 0 0
0 0 0
15.1.6.2 BP-2 (35 GPM /43 FT) Set 1 0 0 0 0 0 1
0 0 0
15.1.6.3 BP-3 (55 GPM /43 ft) Set 0 0 1 0 1 0 0
0 0 0
15.20 FIRE FIGHTING SYSTEM 0 0 0 0 0 0 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0 0 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0 0 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 5 0 8 0 7 0 7


0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 55/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0 0 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 2 0 4 0 3 0 3


0 0 0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0 0 0
per owner instructions"

15.2.3 Fire blanket No. 2 0 4 0 3 0 3


0 0 0
15.30 PLUMBING FIXTURE APPLIANCES 0 0 0 0 0 0 0
0 0 0
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains
0 0 0
including adapters, branches, tees, valves, supports
from galvanized steel, brackets, hangers ,shelves,
siphon, terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications
0 0 0
Water Closet

Western type vitreous china water cloSet complete


with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0 0 0 0
connection as specified.

WC-01 ( Supply and install ) for Maids rooms (ideal


15.3.1.1 No. 3 0 1 0 2 0 2
standard or equivlant)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 56/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
install only ,connection and testing wall mounted WC
complete with but not limited to concealed
tank with actuator flush panel or pneumatic
push button for washdown wall-hung toilets and
Chrome hand spry Include adjustable wall bracket with
min. 1.2 m hose
System shall fit within minimum 51
⁄2" (146 mm) framing wall or plumbing chase, with
steel framing members Framing members
should be capable of supporting 400 kg load without
damage to the wall. Water
supply shall have minimum flow
pressure of 2 PSI (0.01 MPa). The toilet bowl
0 0 0
shall be a third party listed low-consumption
1.6/0.8 GPF (6/3 LPF) dualflush
2-hole wall-hung type. The carrier frame
shall be adjustable for bowl rim heights from
15" to 19" (381 to 483 mm). Actuator flush
panels shall be diecast zinc, molded plastic or
fabricated stainless steel and plated to
preserve material integrity. All components
shall be compliant with applicable codes and
product standards.

WC-02 Install Only ( Fixtures Purchase by Client -Part


15.3.1.2 No. 8 0 15 0 12 0 10
of ID )

0 0 0
Lavatories
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer and 800x900mm wall 0 0 0 0
mirror with chamfered edge including all the necessary
fittings & accessories and approved by the owner .

( Lav-01 ) ( Supply and install for Maids rooms ( ideal


15.3.2.1 standard inclusive of water mixer grohe or equivlant ) No. 5 0 2 0 2 0 2

Supply ,install ,connection and testing for recessed


mounted Lavatories complete including wash basin 0 0 0
mixer with but not limited to hangers support
(galvanized steel made)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 57/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
15.3.2.2 ( Lav-02 ) Install Only ( Fixtures Purchase by Client No. 13 0 21 0 15 0 14
-Part of ID )

Bathtub
Supply and install bathtub ,complete, including water
feed, waste and vent branch piping works to mains
including adapters, branches, tees, valves, mixer,
supports, brackets, hangers , siphon ..etc. all as
specifications, drawings and water consumption 0 0 0
rationalization specifications all model must approved
from owner representative and consultant. only as
required for fixture installation and to wall connection .
BT-02 Install ony ( Fixture Purchase by Client -Part of
15.3.3.2 No. 0 0 0 0 5 0 4
ID )
0 0 0
kitchen sink 0 0 0
Excluded- At this stage 0 0 0
0 0 0
Shower Hand mixer 0 0 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (as per owner 0 0 0
representative and consultant.)
0 0 0
15.3.9.1 SH-01 (sypply and install) grohe Type or equivalent . No. 0 0 0 0 2 0 2
0 0 0
15.3.9.2 SH-02 Install Only ( Fixtures Purchase by Client -Part of No. 0 0 7 0 11 0 7
ID )
0 0 0
15.40 STORMWATER AND DRAINAGE SYSTEM 0 0 0 0 0 0 0
0 0 0
15.4.1 Pipework 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 58/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0 0 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0 0 0
15.4.1.1 50 mm diameter pipe LM 45 0 52 0 35 0 35
0 0 0
15.4.1.2 80 mm diameter pipe LM 95 0 103 0 98 0 104
0 0 0
15.4.1.3 110 mm diameter pipe LM 164 0 280 0 158 0 156
0 0 0
15.4.1.4 160 mm diameter pipe LM 35 0 85 0 0 0 0
0 0 0
0 0 0
Floor Drain 0 0 0
0 0 0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0 0 0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0 0 0
15.4.1.5 FD-80 mm outlet diameter No. 17 0 27 0 16 0 19
0 0 0
0 0 0
Floor Cleanout 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 59/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0 0 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0 0 0
15.4.1.7 FCO- 110mm No. 5 0 15 0 0 0 2
0 0 0
15.4.1.8 WCO- 110mm No. 0 0 0 0 9 0 4
0 0 0
Trench Drain 0 0 0
0 0 0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as 0 0 0
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0 0 8 0 0 0 0


Inspection room 0 0 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and No. 9 0 1 0 3 0 0
as shown on drawings .

0 0 0
Gully trap 0 0 0
Constructing , connecting and testing Gully trap
complete with heavy duty cast iron cover and all other
accessories all as specifications and as shown on
15.4.1.9.2 No. 0 0 0 0 0 0 0
drawings

0 0 0
Submersible Pumps 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 60/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0 0 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-01 (35 GPM / 18 FT )
15.4.1.10 set 1 0 0 0 0 0 0

0 0 0
Roof Drain 0 0 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0 0 0
with accessories all as specified and shown on drawing.

0 0 0
15.4.1.15 RD, 110mm outlet diameter No. 4 0 8 0 0 0 6
0 0 0
15.4.1.16 RD, 75mm outlet diameter No. 1 0 0 0 0 0 2
0 0 0
Down spout 0 0 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0 0 0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 2 0 8 0 10 0 6


0 0 0
0 0 0
0 0 0
Roof Vent Cap 0 0 0
0 0 0
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner 0 0 0
instructions"

15.4.1.19 Type RVC, 110 mm diameter pipe No. 5 0 12 0 10 0 10


0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 61/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

15.50 HVAC SYSTEM 0 0 0 0 0 0 0


BUILDER'S WORK RELATED TO MECHANICAL
0 0 0
WORKS
0 0 0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 1 0 1 0 1 0 1
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0 0 0
LABELING AND IDENTIFYING 0 0 0
0 0 0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 1 0 1 0 1 0 1
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0 0 0
15.5.3 AIR CONDITIONERS UNITS 0 0 0 0 0 0 0
0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 62/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply, install, test and commission Packaged roof
mounted air-condition unit, (HEAT PUMP TYPE)
according to the following specifications : Heavy gauge
galv. Steel sheet, with electrostatic powder paint of
epoxy coating finish. Double skin unit casing with
suitable thermal insulation, Weather proof, Hermetic
sealed scroll compressors Refrigerant , Micro processor
controller, Return fan and supply fan, Aluminum Flat
Filter, Economizer section, Mixing box with
automatically operated fresh air damper, External
overload protections for all compressors and circuit
breaker for the unit. Evaporator coil and condenser coil
15.5.3.1 made of copper tubes and aluminum fins, Thermal 0 0 0 0 0 0 0
expansion valve, Gas control, Filter driers, Sight glass,
Solenoid valves; High and low pressure cutouts; Oil
pressure switches; Air and fire dampers. Drain system
for condensate water Anti vibration pads; Concrete
bases; Inside air temperature controlling according to
ASHRAE standards and All electrical wiring and
conduits required, Kinetic Float Base, Equipment
capacities as tabulated on the drawings. By Daikin
manuf. or equivelant

15.5.3.1.4 PAC-04 6TR No. 1 0 0 0 0 0 0


0 0 0
15.5.3.1.5 PAC-05 7.5TR No. 0 0 0 0 0 0 0
0 0 0
15.5.3.1.6 PAC-06 8.5TR No. 0 0 2 0 0 0 0
0 0 0
15.5.3.1.7 PAC-07 - 10TR No. 1 0 3 0 0 0 0
0 0 0
15.5.3.1.9 PAC-09 - 15TR No. 0 0 1 0 0 0 0
0 0 0
15.5.3.1.10 PAC-10 24TR No. 0 0 2 0 0 0 0
0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 63/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
power connections between the isolator switch and the
15.5.3.2 outdoor unit, vibration isolators, hangers for the indoor 0 0 0 0 0 0 0
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Concealed Type - for Vills 0 0 0


15.5.3.2.1.1 FCU-01 - 1.5TR 2 0 0 0 3 0 0
0 0 0
15.5.3.2.1.2 FCU-02 - 2TR 2 0 0 0 0 0 2
0 0 0
15.5.3.2.1.3 FCU-03 - 2.5TR 3 0 7 0 1 0 0
0 0 0
15.5.3.2.1.4 FCU-04 - 3TR 2 0 0 0 5 0 2
0 0 0
15.5.3.2.1.5 FCU-05 - 3.5TR 1 0 1 0 7 0 9
0 0 0
15.5.3.2.1.6 FCU-06 - 4TR 0 0 0 0 3 0 0
0 0 0
15.5.3.2.1.8 FCU-08 - 5TR 1 0 0 0 1 0 4
0 0 0
Cassette units - for Kitchens 0 0 0
0 0 0
15.5.3.2.1.9 CDX-01 -1.5TR 1 0 0 0 3 0 0
0 0 0
15.5.3.2.1.10 CDX-02 - 2TR 0 0 0 0 0 0 0
0 0 0
15.5.3.2.1.11 CDx-03 -2.5TR 0 0 4 0 0 0 3
0 0 0
Split Wall mounted Type - For service Drivers , 0 0 0
Maid stores .. 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 64/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
15.5.3.2.1.12 WDX-01 -1TR 2 0 5 0 1 0 1
0 0 0
15.5.3.2.1.13 WDX-02 -1.5TR 0 0 3 0 5 0 5
0 0 0
0 0 0
15.5.3.3 Refrigeration Unit Type 0 0 0 0 0 0 0
0 0 0
Supply, install, test and commission refrigeration unit
type with appropriate compressors, evaporators,
refrigeration gas and all components and accessories. 0 0 0

0 0 0
15.5.3.3.1 Ref. ROU-01 / RIU-01 -Ref. ROU-B02-1 / RIU-B02-1 No. 0 0 3 0 0 0 0
0 0 0
15.5.3.3.2 Ref. ROU-02 / RIU-02 -Ref. ROU-B02-2 / RIU-B02-2 No. 0 0 1 0 0 0 0
0 0 0
0 0 0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0 0 0 0 0 0 0

0 0 0
Supply, install, test and commission centrifugal in line/
roof mounted (Roof Top Type) belt drive exhaust fan
with external motor installation for kitchen hoods, fans
shall be able to operate for no less than one hour at
high temperature , complete with steel bases, steel
box, frames, rubber pads, sealers for leakage, access
panels , flexible connections with ducts, guard screens,
back draft damper with all fixing, support, grease 0 0 0
drain , and all required accessories and all required
accessories for proper installation and as per specs &
dwgs. "suadi fans , greenheck, ASEM or equivalent as
per owner instructions"

15.5.4.1 HEF-B01-G-01 No. 1 0 0 0 0 0 0


0 0 0
15.5.4.2 HEF-B02-B-01 No. 0 0 1 0 0 0 0
0 0 0
15.5.4.4 HEF-B02-B-02 No. 0 0 1 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 65/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
15.5.4.4.1 HEF-B02-B-03 0 1 0 0 0 0
0 0 0
15.5.4.5 HEF-B03-B-01 0 0 0 1 0 0
0 0 0
15.5.4.6 HEF-B03-G-01 No. 0 0 0 0 1 0 0
0 0 0
15.5.4.7 HEF-B03-FR-01 No. 0 0 0 0 1 0 0
0 0 0
15.5.4.8 HEF-B04-B-01 No. 0 0 0 0 0 0 1
0 0 0
15.5.4.9 HEF-B04-G-01 No. 0 0 0 0 0 0 1
0 0 0
15.5.4.10 HEF-B04-G-02 No. 0 0 0 0 0 0 1
0 0 0
15.5.4.11 HEF-B07-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.12 HEF-B07-B-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.13 HEF-B07-B-03 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.14 HEF-B09-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.14.1 HEF-B10-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.14.2 HEF-B10-B-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.15 HEF-B11-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.16 HEF-B11-B-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.17 HEF-B11-B-03 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.18 HEF-B11-B-04 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.19 HEF-B11-B-05 No. 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 66/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0 0 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

Fan Section (belt driven) 0 0 0


0 0 0
15.5.4.20 MAF-B02-B-01 No. 0 0 1 0 0 0 0
0 0 0
15.5.4.21 MAF-B02-B-02 No. 0 0 1 0 0 0 0
0 0 0
15.5.4.22 MAF-B07-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.23 MAF-B07-B-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.24 MAF-B07-B-03 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.25 MAF-B11-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.26 MAF-B11-B-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.27 FAF-B01-01 No. 1 0 0 0 0 0 0
0 0 0
15.5.4.30 FAF-B03-01 No. 0 0 0 0 1 0 0
0 0 0
15.5.4.31 FAF-B04-01 No. 0 0 0 0 0 0 1
0 0 0
15.5.4.32 FAF-B05-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.33 FAF-B05-02 No. 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 67/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
15.5.4.34 FAF-B07-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.35 FAF-B07-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.36 FAF-B07-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.37 FAF-B08-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.38 FAF-B09-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.39 FAF-B10-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.40 FAF-B10-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.41 FAF-B11-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.42 FAF-B11-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.43 FAF-B12-G-01 No. 0 0 0 0 0 0 0
0 0 0
0 0 0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0 0 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0 0 0
0 0 0
15.5.4.45 EXF-B01-B-02 ( Roof top ) No. 1 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 68/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
15.5.4.46 EXF-B01-B-03( Roof top ) No. 1 0 0 0 0 0 0
0 0 0
15.5.4.47 EXF-B01-G-01( Roof top ) No. 1 0 0 0 0 0 0
0 0 0
15.5.4.48 EXF-B01-G-02( Roof top ) No. 1 0 0 0 0 0 0
0 0 0
15.5.4.52 EXF-B02-B-01( Roof top ) No. 0 0 1 0 0 0 0
0 0 0
15.5.4.53 EXF-B02-B-02( Roof top ) No. 0 0 1 0 0 0 0
0 0 0
15.5.4.54 EXF-B02-B-03( IN LINE ) No. 0 0 1 0 0 0 0
0 0 0
0 0 0
15.5.4.55 Ditto but Centrifugal in line fan 0 0 1 0 0 0 0
0 0 0
15.5.4.56 EXF-B02-G-02( IN LINE ) No. 0 0 1 0 0 0 0
0 0 0
15.5.4.57 EXF-B02-G-03( IN LINE ) No. 0 0 1 0 0 0 0
0 0 0
15.5.4.58 EXF-B02-G-04( IN LINE ) No. 0 0 2 0 0 0 0
0 0 0
15.5.4.59 EXF-B02-G-05( IN LINE ) No. 0 0 1 0 0 0 0
0 0 0
15.5.4.60 EXF-B02-G-06( IN LINE ) No. 0 0 1 0 0 0 0
0 0 0
15.5.4.61 EXF-B02-G-07( IN LINE ) No. 0 0 1 0 0 0 0
0 0 0
15.5.4.62 EXF-B06-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.63 EXF-B06-G-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.64 EXF-B06-G-02 No. 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 69/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
15.5.4.65 EXF-B06-G-03 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.66 EXF-B06-G-04 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.67 EXF-B07-B-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.68 EXF-B07-B-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.69 EXF-B07-B-03 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.70 EXF-B07-B-04 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.71 EXF-B07-B-05 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.72 EXF-B07-F-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.73 EXF-PAC-B07-01(INLINE) No. 0 0 0 0 0 0 0
0 0 0
15.5.4.75 EXF-B08-G-01(INLINE) No. 0 0 0 0 0 0 0
0 0 0
15.5.4.76 EXF-PAC-B08-01(INLINE) No. 0 0 0 0 0 0 0
0 0 0
15.5.4.77 EXF-PAC-B08-02(INLINE) No. 0 0 0 0 0 0 0
0 0 0
15.5.4.78 EXF-PAC-B08-03(INLINE) No. 0 0 0 0 0 0 0
0 0 0
15.5.4.82 EXF-PAC-B11-01(INLINE) No. 0 0 0 0 0 0 0
0 0 0
15.5.4.83 EXF-B12-G-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.84 EXF-B12-G-02 No. 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 70/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
15.5.4.85 EXF-PAC-B12-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.86 EXF-PAC-B12-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.4.90.1 AEX-B02-01 NO 0 0 1 0 0 0 0
15.5.4.90.2 AEX-B04-02 0 0 0 0 0 0 1
0 0 0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0 0 0
greenheck, ASEM or equivalent as per owner
instructions"
0 0 0
15.5.4.91 CEX-01 No. 9 0 7 0 16 0 13
15.5.4.92 CEX-02 No. 0 0 0 0 2 0 2
0 0 0
Supply, install test & commission air curtain all
required accessories as per specs and schedule . 0 0 0

0 0 0
15.5.4.93 AC-01 No. 0 0 0 0 0 0 0
15.5.4.94 AC-02 No. 0 0 0 0 0 0 0
0 0 0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0 0 0
greenheck, ASEM or equivalent as per owner
instructions"
0 0 0
15.5.4.95 WEX-B02-01 NO 0 0 1 0 0 0 0
0 0 0
15.5.4.96 WEX-B03-01 NO 0 0 0 0 1 0 0
0 0 0
15.5.4.97 WEX-B04-01 NO 0 0 0 0 0 0 2
0 0 0
15.5.4.98 WEX-B06-01 0 0 0 0 0 0 0
0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 71/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

15.5.5 Condensate Pipework 0 0 0 0 0 0 0


0 0 0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick 0 0 0
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0 0 0
15.5.5.1 25 mm outside diameter pipe LM 80 0 180 0 187 0 234
0 0 0
15.5.5.4 50mm outside diameter pipe LM 0 0 112 0 0 0 0
0 0 0
15.5.6 Ductwork 0 0 0 0 0 0 0
0 0 0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 1266 0 5508 0 1195 0 1870
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 72/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 1 0 3 0 3 0 3
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0 0 0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 1 0 3 0 3 0 3
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0 0 0
Supply ,install ,connect ,test and commission
protection, aluminum cladding for external duct,
15.5.6.4 kg 152 0 1165 0 0
complete with but not limited to all acessories , flow
indicators, labels, color code stickers,….etc
0 0 0
15.5.7 Ductwork Insulation 0 0 0 0 0 0 0
0 0 0

Supply, install, connect, test and commission


Fiberglass blanket duct insulation for supply, fresh air
and return ductwork, Fiberglass insulation 25mm thick
density 24kg/m3, factory laminated to a reinforced foil
15.5.7.1 Kraft vapour barrier facing covered with canvas fabric m2 206 0 824 0 201 0 340
wrap and two layers of fungus resistant mastic,
installed connected and tested complete including self
adhesive fixing pins, sealing tape, wire banding and
accessories all as specified and shown on drawings.

0 0 0
15.5.7.2 Ditto but with thikness 50 mm and 48 kg/m³ desity m2 47 0 364 0 0
0 0 0
15.5.8 Duct Acoustic Inner Liner 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 73/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supply, install, connect, test and commission Duct


acoustic inner liner Rubber insulation thickness 13 mm
fixed with fire resistant adhesive and mechanical
15.5.8.1 LS 1 0 1 0 1 0 1
fasteners, installed, connected and tested complete
with accessories, to meet NC as specified and shown
on drawings.

0 0 0
15.5.9 Air Diffusers, Registers, and Grilles 0 0 0 0 0 0 0
0 0 0
Supply, install, connect, test and commission, Supply
Linear Slotting Diffuser as per drawings, complete with
volume dampers, insulated plenum box and including 0 0 0
all accessories to complete the work.. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

0 0 0
15.5.9.1 SLD - 1 LM 0 0 0 0 0 0 0
0 0 0
15.5.9.2 SLD - 2 LM 13 0 0 0 10 0 0
0 0 0
15.5.9.3 SLD - 3 LM 5 0 0 0 12 0 24
0 0 0
15.5.9.4 SLD - 4 LM 48 0 0 0 34 0 10
0 0 0
15.5.9.5 SLD - 5 LM 17 0 60 0 35 0 15
0 0 0
15.5.9.6 SLD - 6 LM 6 0 14 0 5 0 15
0 0 0
15.5.9.7 SLD - 7 LM 0 0 0 0 0 0 0
0 0 0
15.5.9.8 SLD - 8 LM 0 0 34 0 0 0 16
0 0 0
Supply, install, connect, test and commission,Return
and installation of return Linear Slotting Diffuser as per
drawings, complete with volume dampers, insulated
plenum box and including all accessories to complete 0 0 0
the work.

15.5.9.9 RLD - 1 LM 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 74/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
15.5.9.10 RLD - 2 LM 13 0 0 0 10 0 0
0 0 0
15.5.9.11 RLD - 3 LM 5 0 0 0 12 0 24
0 0 0
15.5.9.12 RLD - 4 LM 48 0 0 0 34 0 10
0 0 0
15.5.9.13 RLD - 5 LM 17 0 60 0 35 0 15
0 0 0
15.5.9.14 RLD - 6 LM 6 0 22 0 5 0 15
0 0 0
15.5.9.15 RLD - 7 LM 0 0 0 0 0 0 0
0 0 0
15.5.9.16 RLD - 8 LM 0 0 10 0 0 0 16
0 0 0
Supply, install, connect, test and commission, powder
coated aluminum register air grill with opposed blade
dampers , color to be selected by the Engineer,
including connections to ductwork with plenum box
0 0 0
and flexible duct, volume damper for balancing
purposes, mounting, fixings and all required
accessories as per specs and drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0 0 0
15.5.9.17 SR-01 No. 0 0 0 0 0 0 6

Diito as above But Return Rabeea, GGC, Beta, or


equivalent as per owner instructions" 0 0 0

15.5.9.18 RR-01 No. 0 0 0 0 0 0 6


0 0 0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0 0 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0 0 0
15.5.9.19 EG-01 No. 7 0 13 0 0 0 0
0 0 0
15.5.9.20 EG-02 No. 0 0 1 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 75/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0 0 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0 0 0
0 0 0
0 0 0
15.5.9.46 EAL-B02-02 No. 0 0 2 0 0 0 0
0 0 0
15.5.9.48 EAL-B02-04 No. 0 0 4 0 0 0 0
0 0 0
15.5.9.52 EAL-B06-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.53 EAL-B06-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.54 EAL-B06-03 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.55 EAL-B07-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.58 EAL-B07-04 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.59 EAL-B07-05 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.60 EAL-B08-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.61 EAL-B08-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.63 EAL-B11-01 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.64 EAL-B11-02 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.65 EAL-B11-03 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.66 EAL-B11-04 No. 0 0 0 0 0 0 0
0 0 0
15.5.9.67 EAL-B12-02 No. 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 76/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
0 0 0
15.60 LPG SYSTEM 0 0 0 0 0 0 0
0 0 0
15.6.1 Pipework 0 0 0 0 0 0 0
0 0 0
Supply, install test & commission, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions" Schedule 40 - inside buildings 0 0 0

only for diwanyah and Guest villa 0 0 0


15.6.1.1 25 mm diameter pipe LM 15 0 3 0 0 0 0
0 0 0
15.6.1.2 32 mm diameter pipe LM 0 0 3 0 0 0 0
0 0 0
15.6.1.3 40 mm diameter pipe LM 15 0 20 0 0 0 0
0 0 0
Supply, install & test PVC coated Copper pipes for gas
system, complete with fittings & all related works
(valves at termination points to be included in the 0 0 0
rate).APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"
15.6.1.4 20 mm diameter pipe LM 20 0 25 0 0 0 0
0 0 0
15.6.2 Gas Valves 0 0 0 0 0 0 0
0 0 0
Supply Isolating ball valves, quarter-turn, installed,
connected, and tested complete including all 0 0 0
accessories, all as specified and shown on drawings.
15.6.2.1 20 mm diameter No. 2 0 5 0 0 0 0
0 0 0
15.6.3 Solenoid Gas Valves 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 77/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply Solenoid gas valves, installed, connected, and
tested, complete including all accessories as specified 0 0 0
and shown on drawings.
0 0 0
15.6.3.1 40 mm diameter No. 1 0 1 0 0 0 0
0 0 0
15.6.4 Gas Regulators 0 0 0 0 0 0 0
0 0 0
Gas regulators, installed, connected, and tested
complete with isolating valve, including all accessories 0 0 0
as specified and shown on drawings.
0 0 0
15.6.4.1 32 mm diameter No. 2 0 5 0 0 0 0
0 0 0
15.6.6 Gas Manifold 0 0 0 0 0 0 0
0 0 0
Supply Gas manifold, installed, tested, complete with
steel cabinets, branch gas valves and accessories, all
as specified and shown on drawings. 0 0 0

0 0 0
15.6.6.1 Gas Manifold No. 4 0 3 0 0 0 0
0 0 0
0 0 0

SWIMMING POOL SYSTEM AND FOUNTAINS 0 0 0 0 0 0 0


15.70
0 0 0
15.7.1 PVC Pipes 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 78/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0 0 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0 0 0
15.7.1.5 63 mm LM 0 0 0 0 0 0 0
0 0 0
15.7.1.6 75 mm LM 0 0 0 0 0 0 0
0 0 0
15.7.1.7 110 mm LM 0 0 0 0 0 0 0
0 0 0
15.7.1.8 160mm LM 0 0 0 0 0 0 0
0 0 0
15.7.2 Swimming pool pump 0 0 0 0 0 0 0
0 0 0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0 0 0

15.7.2.4 FP-B07-1 No. 0 0 0 0 0 0 0


0 0 0
15.7.2.5 FP-B11-1 No. 0 0 0 0 0 0 0
0 0 0
15.7.2.6 FP-B12-1 No. 0 0 0 0 0 0 0
0 0 0
15.7.3 Inlet Fitting 0 0 0 0 0 0 0
0 0 0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0 0 0
specified and shown on drawings

0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 79/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0 0 0 0 0 0 0


15.7.4 Vacuum Fitting 0 0 0 0 0 0 0
0 0 0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0 0 0
drawings

0 0 0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0 0 0 0 0 0 0
0 0 0
15.7.5 Main Drain 0 0 0 0 0 0 0
0 0 0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0 0 0
shown on drawings
0 0 0
15.7.5.1 Main drain MD No. 0 0 0 0 0 0 0
0 0 0
15.7.6 Overflow Trench Fitting 0 0 0 0 0 0 0
0 0 0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0 0 0
spesified and shown on drawings.

0 0 0
15.7.6.1 Overflow Trench LM 0 0 0 0 0 0 0
0 0 0
15.7.7 Outlet Fitting 0 0 0 0 0 0 0
0 0 0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
0 0 0
specified and shown on drawings

0 0 0
15.7.7.1 Outlet fitting 75mm diameter No. 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 80/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
15.7.8 Fill Fitting 0 0 0 0 0 0 0
0 0 0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0 0 0

0 0 0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0 0 0 0 0 0 0
0 0 0
15.7.9 Pool Sand Filter 0 0 0 0 0 0 0
0 0 0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0 0 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

15.7.9.1 SF-B07-1 No. 0 0 0 0 0 0 0


0 0 0
15.7.9.2 SF-B11-1 Set. 0 0 0 0 0 0 0
0 0 0
15.7.9.3 SF-B12-1 Set. 0 0 0 0 0 0 0
0 0 0
15.7.10 Chemical Feeding and Control Accessories 0 0 0 0 0 0 0
0 0 0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0 0 0

0 0 0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0 0 0 0 0 0 0
0 0 0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0 0 0

0 0 0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0 0 0 0 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 81/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

15.7.10.3 Chemical test kit No. 0 0 0 0 0 0 0


0 0 0
15.7.11 Balance Tank 0 0 0 0 0 0 0
0 0 0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0 0 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0 0 0
Capacity (4) m3 0 0 0
15.7.11.1.1 BT-B07-1 No. 0 0 0 0 0 0 0
15.7.11.1.2 BT-B11-1 No. 0 0 0 0 0 0 0
15.7.11.1.3 BT-B12-1 No. 0 0 0 0 0 0 0
0 0 0
15.7.12 Electrical Heat Exchanger 0 0 0 0 0 0 0
0 0 0
Supply Stainless steel pool heat exchanger, installed 0 0 0
and tested complete with Digital Thermostat, valves, 0 0 0
control valve & all related works as specified and 0 0 0
shown on drawings. 0 0 0
0 0 0
Pool Heat Exchanger H.X 0 0 0
15.7.12.1 P- HE-01 (21 KW) No. 0 0 0 0 0 0 0
0 0 0
15.7.12.2 P- HE-02 (30 KW) No. 0 0 0 0 0 0 0
0 0 0
0 0 0
DIV#15 Total cost of this section Carried Forward To Summary - - -

16.10 DIV#16 ELECTRICAL WORKS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 82/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.1.1 Ref. SMDB-DW No. 1 0 0 0 0 0 0


16.1.2 Ref. SMDB-G.V No. 0 0 1 0 0 0 0
16.1.3 Ref. ESMDB-G.V No. 0 0 1 0 0 0 0
16.1.4 Ref. SMDB-M.V No. 0 0 0 0 1 0 0
16.1.5 Ref. SMDB-A.V No. 0 0 0 0 0 0 1
16.1.6 Ref. SMDB-D.A/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0
16.1.7 Ref. SMDB-C.H No. 0 0 0 0 0 0 0
16.1.8 Ref. ESMDB-C.H No. 0 0 0 0 0 0 0
16.1.9 Ref. SMDB-MA No. 0 0 0 0 0 0 0
16.1.10 Ref. ESMDB-MA No. 0 0 0 0 0 0 0
16.1.11 Ref. SMDB-NA No. 0 0 0 0 0 0 0
16.1.12 Ref. SMDB-DM&N No. 0 0 0 0 0 0 0
16.1.13 Ref. SMDB-A'A.V No. 0 0 0 0 0 0 0
16.1.14 Ref. SMDB-M.V/X (X: R, L) No. 0 0 0 0 0 0 0
16.1.15 Ref. SMDB-DI&A No. 0 0 0 0 0 0 0
16.1.16 Ref. SMDB-I No. 0 0 0 0 0 0 0
16.1.17 Ref. SMDB-AE No. 0 0 0 0 0 0 0
0 0 0
16.20 Motor Control Center 0 0 0 0 0 0 0
Section 16443 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 83/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0 0 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

0 0 0
0 0 0
0 0 0
16.2.1 Ref. MCC-R No. 1 0 1 0 1 0 1
16.2.1.1 Ref. MCC-R/I No. 0 0 0 0 0 0 0
16.2.2 Ref. EMCC-R No. 0 0 1 0 0 0 0
16.2.3 Ref. MCC-R/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0
16.2.4 Ref. MCC-R1/M No. 0 0 0 0 0 0 0
16.2.5 Ref. MCC-R2/M No. 0 0 0 0 0 0 0
16.2.6 Ref. MCC-P/M No. 0 0 0 0 0 0 0
16.2.7 Ref. MCC-R1/N No. 0 0 0 0 0 0 0
16.2.8 Ref. MCC-R2/N No. 0 0 0 0 0 0 0
16.2.9 Ref. MCC-P/N No. 0 0 0 0 0 0 0
16.2.10 Ref. MCC-R/X (X: R, L) No. 0 0 0 0 0 0 0
0 0 0
16.30 Distribution Boards 0 0 0 0 0 0 0
16.3.1 Ref. DB-B No. 1 0 0 0 1 0 1
16.3.2 Ref. DB-G No. 1 0 0 0 1 0 1
16.3.3 Ref. DB-F No. 1 0 0 0 1 0 1
16.3.3.1 Ref. DB-F/AE 0 0 0 0 0 0 0
16.3.4 Ref. DB-R No. 1 0 0 0 1 0 1
16.3.4.1 Ref. DB-R/AE 0 0 0 0 0 0 0
16.3.5 Ref. EDB-G/I No. 1 0 0 0 0 0 1
16.3.5.1 Ref. EDB-G/AE 0 0 0 0 0 0 0
16.3.6 Ref. EDB-F No. 1 0 0 0 0 0 0
16.3.8 Ref. DP-B/I No. 0 0 1 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 84/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
16.3.8.1 Ref. DP-B/AE No. 0 0 0 0 0 0 0
16.3.9 Ref. DL-B No. 0 0 1 0 0 0 0
16.3.10 Ref. EDB-B No. 0 0 1 0 1 0 0
16.3.10.1 Ref. DB-G-DI&A 0 0 0 0 0 0 0
16.3.11 Ref. EDB-K No. 0 0 1 0 0 0 0
16.3.12 Ref. DP-G No. 0 0 1 0 0 0 0
16.3.13 Ref. DL-G No. 0 0 1 0 0 0 0
16.3.14 Ref. EDB-G No. 0 0 1 0 0 0 0
16.3.15 Ref. DP-F No. 0 0 1 0 0 0 0
16.3.16 Ref. DL-F No. 0 0 1 0 0 0 0
16.3.17 Ref. DB-B/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0
16.3.18 Ref. DB-G/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0
16.3.19 Ref. DB-F/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0
16.3.23 Ref. DB-R/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0
16.3.24 Ref. DB-GR No. 0 0 0 0 0 0 0
16.3.25 Ref. DB-GL No. 0 0 0 0 0 0 0
16.3.26 Ref. DB-EX No. 0 0 0 0 0 0 0
16.3.27 Ref. DB-SM No. 0 0 0 0 0 0 0
16.3.28 Ref. EDB-S No. 0 0 0 0 0 0 0
16.3.29 Ref. DB-GM No. 0 0 0 0 0 0 0
16.3.30 Ref. EDB-GM No. 0 0 0 0 0 0 0
16.3.31 Ref. DB-FM No. 0 0 0 0 0 0 0
16.3.32 Ref. DB-RM No. 0 0 0 0 0 0 0
16.3.33 Ref. DB-KM No. 0 0 0 0 0 0 0
16.3.34 Ref. EDB-KM No. 0 0 0 0 0 0 0
16.3.35 Ref. DB-SP No. 0 0 0 0 0 0 0
16.3.36 Ref. DB-SL No. 0 0 0 0 0 0 0
16.3.37 Ref. DB-KN No. 0 0 0 0 0 0 0
16.3.38 Ref. EDB-KN No. 0 0 0 0 0 0 0
16.3.39 Ref. DB-GN No. 0 0 0 0 0 0 0
16.3.40 Ref. DB-FN No. 0 0 0 0 0 0 0
16.3.41 Ref. DB-RN No. 0 0 0 0 0 0 0
16.3.42 Ref. EDB-GN No. 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 85/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
16.3.43 Ref. DB-B/S No. 0 0 0 0 0 0 0
16.3.44 Ref. EDB-S No. 0 0 0 0 0 0 0
16.3.45 Ref.DB-DM&N No. 0 0 0 0 0 0 0
16.3.46 Ref.EDB-DM&N No. 0 0 0 0 0 0 0
16.3.47 Ref. DB-B/X (X: R, L) No. 0 0 0 0 0 0 0
16.3.48 Ref. DB-G/X (X: R, L) No. 0 0 0 0 0 0 0
16.3.49 Ref. DB-F/X (X: R, L) No. 0 0 0 0 0 0 0
16.3.50 Ref. EDB-B/X (X: R, L) No. 0 0 0 0 0 0 0
16.3.51 Ref. DB-K/X (X: R, L) No. 0 0 0 0 0 0 0
16.3.52 Ref. DB-R/X (X: R, L) No. 0 0 0 0 0 0 0
0 0 0
16.40 Feeders 0 0 0 0 0 0 0
Section 16122 0 0 0

Feeders, conductors and cables including all necessary


supports, brackets, pipes, cable trayes (where needed) ,
conduits, manholes (if needed), luges, glands, cable 0 0 0
terminaL.S , terminations and electrical connections and
all needed accessories as shown on the drawings.

0 0 0
16.4.1 2(4x240) mm2 CU/XLPE/SWA/PVC LM 0 0 120 0 0 0 0
16.4.4 4x300mm² CU/XLPE/SWA/PVC LM 185 0 240 0 120 0 0
16.4.5 4x240 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 75
16.4.6 4x185 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0
16.4.7 4x150 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0
16.4.8 4x120 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0
16.4.9 4x70 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0
16.4.10 4x240mm² CU/XLPE/PVC + 1x120mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0
16.4.11 4x150mm² CU/XLPE/PVC + 1x70mm² Y/G PVC CABLE LM 0 0 25 0 0 0 0
16.4.12 4x120mm² CU/XLPE/PVC + 1x70mm² Y/G PVC CABLE LM 0 0 25 0 50 0 0
16.4.13 4x95mm² CU/XLPE/PVC + 1x50mm² Y/G PVC CABLE LM 30 0 0 0 0 0 35
16.4.14 4x70mm² CU/XLPE/PVC + 1x35mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0
16.4.15 4x50mm² CU/XLPE/PVC + 1x25mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0

16.4.16 4x25mm² CU/XLPE/SWA/PVC + 1x16mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 86/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
16.4.17 4x35mm² CU/XLPE/SWA/PVC LM 370 0 0 0 0 0 0

16.4.19 4x10mm² CU/XLPE/SWA/PVC + 1x10mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0

16.4.20 4x16mm2 CU/XLPE/PVC/PVC +1X16mm² Y/G PVC LM 20 0 35 0 30 0 150


16.4.21 4x10mm² CU/PVC/PVC+1x10mm² Y/G PVC CABLE LM 25 0 95 0 165 0 15
16.4.22 5x6mm² CU/PVC/PVC CABLE LM 65 0 0 0 15 0 60
16.4.23 3x6mm² CU/PVC/PVC CABLE LM 0 0 40 0 0 0 20
0 0 0
16.50 Isolating switches 0 0 0 0 0 0 0
0 0 0

Supply, install, test and commission Isolating switch


points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0 0 0
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

0 0 0
16.5.1 25A, SPN ,IP65 No. 9 0 22 0 15 0 0
16.5.2 25A, TPN ,IP65 No. 6 0 0 0 3 0 11
16.5.3 32A, SPN ,IP65 No. 10 0 0 0 6 0 3
16.5.4 32A, TPN ,IP65 No. 2 0 5 0 12 0 4
16.5.5 32A, SPN ,IP54 for D.W No. 0 0 2 0 1 0 14
16.5.6 40A, TPN ,IP65 No. 1 0 1 0 1 0 1
16.5.7 50A, TPN ,IP65 No. 1 0 2 0 0 0 0
16.5.8 63A, TPN ,IP66 No. 0 0 0 0 0 0 0
16.5.9 80A, TPN ,IP65 No. 0 0 0 0 0 0 0
16.5.10 100A, TPN ,IP65 No. 0 0 0 0 0 0 0
0 0 0
16.60 Power Socket Outlets 0 0 0 0 0 0 0
Sections 16020, 16120, 16130 ,16140 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 87/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supply, install, test and commission Socket outlet


pints only including all necessary PVC conduits,
wires, cables, pull and junctions boxes , floor boxes
(where needed as per drawings) ,cover plates , 0 0 0
ancillaries , connections, and all needed accessories
as shown on the drawings . excluding outlet device
and face plate .

0 0 0
Socket outlet, 13A, 1- phase, 1- gang , switched (wall or 58 0 110 0 96 0 78
16.6.1 No.
in floor mounted box)

16.6.2 Ditto but ceiling mounted No. 19 0 15 0 42 0 38

16.6.3 Ditto but water proof No. 17 0 29 0 15 0 39

16.6.4 Ditto but double gang(wall or in floor mounted box) No. 43 0 13 0 25 0 21

16.6.5 Ditto but double gang water proof No. 0 0 0 0 0 0 0

16.6.6 Power points for motorized shutter No. 11 0 0 0 6 0 2

16.6.7 Spur outlet for electrical water heater No. 0 0 14 0 13 0 10

16.6.9 Power points for hand & hair ddryer No. 0 0 0 0 0 0 4

16.6.13 Power points for Jaccuzi OR Fountains No. 0 0 1 0 7 0 0

20A, double pole switch with neon.


16.6.8 No. 0 0 0 0 0 0 0

Socket outlet, 15A, 1- phase, 1- gang , for washer or 0 0 10 0 0 0 0


16.6.10 No.
dryer

16.6.11 Ditto but 3-phase No. 0 0 0 0 0 0 0

16.6.11.1 FLOOR BOX 2P+1D No. 0 0 5 0 0 0 0

16.6.11.2 FLOOR BOX 1P+1TV No. 0 0 0 0 0 0 5

16.6.11.3 FLOOR BOX 2P+1D+1TV No. 0 0 2 0 0 0 1

0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 88/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
WIRING DEVICES : 0 0 0

INSTALL ONLY ( SUPPLY BY OTHERS) WIRING 0 0 0


DEVICES INCLUDES ALL ACCESSORIES , (GFCI)

0 0 0
Single Switched socket 13A,220v (2P+E) Grounding type 58 0 100 0 80 0 69
16.6.14 NO

16.6.15 Double socket 13A,220v (2P+E),Grounding type NO 42 0 13 0 21 0 21

Single socket 13A,220v (2P+E) GFCI,with earth leakage 17 0 29 0 0 0 30


16.6.16 NO
protection

celing power socket 13A ,220v for AC (2P+E) 19 0 15 0 57 0 77


16.6.17 NO
Grounding type

16.6.18 Single socket 20A,220v (2P+E) FOR WATER HEATER NO 0 0 14 0 13 0 10

16.6.19 2phase socket 20A,220v (3P+E) with neon type, NO 0 0 0 0 0 0 0

SUPPLY AND INSTALL WIRING DEVICES


INCLUDES ALL ACCESSORIES (GFCI) 0 0 0
for maid , laundary, storage rooms

SUPPLY AND INSTALL Single Switched socket 13A,220v 0 0 10 0 16 0 9


16.6.21 NO
(2P+E) Grounding type (legrand/MK) or eqivelant

16.6.22 Double socket 13A,220v (2P+E),Grounding type NO 1 0 4 0 4 0 0

wall power socket 32 A ,220v for AC (2P+E) Grounding


16.6.23 type WATHER PROOF NO 0 0 5 0 0 0 1

0 0 0
16.70 Lighting System 0 0 0 0 0 0 0
Sections 16010, 16120 ,16510 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 89/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supply, install, test and commission Lighting points


with all necessary conduits, conductors , cables &
wires , junction , pull boxes, connections, 0 0 0
accessories, fittings, and all needed accessories as
shown on the drawings.

0 0 0
16.7.1 Internal Lighting points with wire size 2.5 mm2 No. 326 0 465 0 418 0 439

16.7.2 External Lighting points with wire size 6 or 10 mm2 No. 18 0 60 0 33 0 57

0 0 0
16.80 Lighting Fixtures 0 0 0 0 0 0 0
Sections 16010, 16120 ,16510 0 0 0

install only test and commission Lighting fixtures


and switches with all necessary accessories and 0 0 0
termination as shown on the drawings.

0 0 0
16.8.1 Type F1 No. 13 0 52 0 53 0 24
16.8.2 Type F2 No. 0 0 0 0 0 0 48
16.8.3 Type F3 No. 0 0 128 0 209 0 130
16.8.4 Type F4 No. 13 0 12 0 33 0 18
16.8.5 Type F5 No. 0 0 0 0 0 0 8
16.8.6 Type F6 No. 37 0 37 0 14 0 12
16.8.7 Type F7 No. 10 0 41 0 25 0 6
16.8.8 Type F8 No. 65 0 19 0 0 0 19
16.8.9 Type F9 No. 15 0 36 0 16 0 12
16.8.10 Type F11 No. 14 0 0 0 9 0 10
16.8.11 Type F12 No. 2 0 0 0 0 0 3
16.8.13 Type F14 No. 10 0 0 0 0 0 0
16.8.14 Type F14E No. 2 0 0 0 0 0 0
16.8.15 Type F15 No. 4 0 3 0 1 0 1

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 90/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
16.8.16 Type F15E No. 4 0 3 0 0 0 0
16.8.17 Type F18 No. 0 0 7 0 0 0 0
16.8.18 Type F19 No. 2 0 15 0 16 0 18
16.8.20 Type EX1 No. 0 0 0 0 0 0 0
16.8.21 Type EX3 No. 0 0 0 0 0 0 0
16.8.22 Type EX4 No. 18 0 136 0 29 0 55
16.8.23 Type EX5 No. 0 0 0 0 0 0 0
16.8.24 Type EX6 No. 0 0 0 0 0 0 0
supply and install,test and commission Lighting
fixtures and lighting switches (All fixtures shall be
supplied in full coordination with client or client's
representative) including all necessary transformer
ballast, switch gear, lamps, lamp holders, diffusers,
internal wires, supports, clamps, conduits,
connections, terminations, fixings, fittings and all 0 0 0
needed accessories and as shown on the drawings.
for maid, laundary, storage rooms

0 0 0
16.8.25 Type F1 No. 0 0 0 0 4 0 2
16.8.26 Type F4 No. 0 0 0 0 2 0 2
16.8.27 Type F9 No. 0 0 0 0 0 0 0
16.8.29 Type F14 No. 0 0 0 0 0 0 0
16.8.30 Type F15 No. 11 0 12 0 3 0 4
16.8.31 Type F15E No. 0 0 8 0 4 0 7
16.8.32 Type F19 No. 0 0 0 0 2 0 2
0 0 0
16.90 Fire Alarm Installation 0 0 0 0 0 0 0
Sections 16710 Fire Alarm 0 0 0
0 0 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reSet button, switches,
batteries, charger, internal conductor, enclosure and all
16.9.1 0 0 0 0 0 0 0
other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 91/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
0 0 0
16.9.1.1 Fire alarm Slave panel, ref. SACP-DW (1 loop) No. 1 0 0 0 0 0 0
16.9.1.2 Fire alarm Slave panel, ref. SACP-G.V (1 loop) No. 0 0 1 0 0 0 0
16.9.1.3 Fire alarm Slave panel, ref. SACP-M.V (1 loop) No. 0 0 0 0 1 0 0
16.9.1.4 Fire alarm Slave panel, ref. SACP-A.V (1 loop) No. 0 0 0 0 0 0 1
16.9.1.5 Fire alarm Slave panel, ref. SACP-D.A/X (1 loop) No. 0 0 0 0 0 0 0
16.9.1.6 Fire alarm Slave panel, ref. SACP-C.H (1 loop) No. 0 0 0 0 0 0 0
16.9.1.7 Fire alarm Slave panel, ref. SACP-M&N (3 loops) No. 0 0 0 0 0 0 0
16.9.1.8 Fire alarm Slave panel, ref. SACP-DM&N (1 loop) No. 0 0 0 0 0 0 0
16.9.1.9 Fire alarm Slave panel, ref. SACP-A.V (1 loop) No. 0 0 0 0 0 0 0

16.9.1.10 Fire alarm Slave panel, ref. SACP-M.V/X (X: R, L) (1 loop) No. 0 0 0 0 0 0 0

16.9.1.11 Fire alarm Slave panel, ref. SACP-DI&A (1 loop) No. 0 0 0 0 0 0 0


16.9.1.12 Fire alarm Slave panel, ref. SACP-I.V (1 loop) No. 0 0 0 0 0 0 0
16.9.1.13 Fire alarm Slave panel, ref. SACP-AE.V (1 loop) No. 0 0 0 0 0 0 0
0 0 0

Addressable Fire alarm devices including covers,


fixings ,conductors, conduits, pull and junction boxes, 0 0 0 0 0 0 0
16.9.2
cables, wires, connections and terminations, and all
needed accessories as shown on the drawings.

0 0 0
16.9.2.1 Addressable smoke detector No. 20 0 27 0 23 0 16
16.9.2.2 Ditto but with sound base No. 11 0 28 0 25 0 36
16.9.2.3 Addressable heat detector No. 1 0 9 0 1 0 5
16.9.2.4 Ditto but with sound base No. 7 0 7 0 0 0 0
16.9.2.5 Break glass station No. 4 0 3 0 3 0 4
16.9.2.6 Audible/visual warning devices indoor No. 3 0 3 0 6 0 4
16.9.2.7 Audible/visual warning devices outdoor No. 4 3 1 0 4
0 0 0
16.10 EARTHING SYSTEM 0 0 0 0 0 0 0
Sections 16125 EARTHING 0 0 0
0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 92/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,8 earthing pits, various
corner earthing points of the building , connected with
16.10.1 ls 1 0 1 0 1 0 1
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0 0 0
16.10.2 ls
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0 0 0
16.11 CCTV SYSTEM 0 0 0 0 0 0 0
0 0 0

Sections 16690 IP network components,16690 , 0 0 0


16738,16739

supply and Install only indoor cameras's points including


all necessary empty PVC conduits from data cabinet to 7 0 4 0 4 0 8
16.11.4 point's location , pull junction boxes, and all needed
accessories as per drawings.

0 0 0
16.12 LOW CURRENT SYSTEMS 0 0 0 0 0 0 0

Sections 16110, 16120, 16130, 16140, 16690 0 0 0


IP network

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 93/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.
components,16700 ,16738,16739 0 0 0

Voice & Data Distribution System

Supply and install of voice & data distribution Equipment,


including but not limited to connections, supports , patch
panel , distributer switches , ends of cables ,data rack 9u
cabenit and all necessary accessories; all in accordance
with the Drawings and Specifications and as approved by
16.12.1.1 owner .  set 0 0 0
A) the main
distributor (SWITCH to connect devices not less than
1000 MB .
B) Distributor SWITCH devices to
wall outlet not less than 100 MB (By Others )

0 0 0

Supply, install, test and commission voice & data


distribution circuit points , including all ,
fixings ,wires, cat6 A ,cable terminals, cable trunks
and trays ,conduits, pull and junction boxes, floor 0 0 0
suuports (where needed as per drawings) ,cover
plates , connections from data rack to the outlet, and
all needed accessories as shown on the drawings.
excluding outlet device and face plate .

0 0 0

16.12.1 RJ45 socket outlet wall No. 20 0 26 0 26 0 24

16.12.2 Access point installed above false ceiling No. 2 0 6 0 5 0 4

16.12.3 RJ45 Data socket outlet , installed in floor mounted box No. 4 0 0 0 0 0 0

16.12.4 RJ45 access point installed above faL.Se ceiling No. 0 0 0 0 5 0 4

RJ45 socket outlet used for IP- camera (only for 3 0 1 0 1 0 8


16.12.5 No.
outdoor type and for indoor at main diwaniah & gust villa)

0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 94/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supply and installation of reception satellite system


including reception and rules dishes , receivers,
amplifiers , LNP, links, boxes and dividers with 1 0 1 0 1 0 1
16.12.5.1 LS
adjustment, calibration, operation and delivery ,
programming of required stations and all in
accordance with the details shown on drawings

0 0 0

supply and install installation and test Mural TV socket


outlet includes boxes, coaxial cables , pipes , conduits 9 0 0 0 17 0 14
16.12.5.2 No.
and all needed accessories , excluding outlet device and
face plate .

0 0 0

Supply, install, test and commission Inter come system


includs indoor unit , out door unit , 2P cables and 0 0 1 0 1 0 1
16.14 LS
connections , PVC conduits , power supply , and all
needed accessories and as shown on the drawings .

0 0 0

Elevators & Dumbwaiter electrical work related 0 0 0 0 0 0 0


16.16 only )

0 0 0

install, test and commission an electrical feeding points


16.16.1 for electrical elevators , with all necessary equipment No. 1 0 1 0 1 0 1
(for specification refer to CONVEYING SYSTEM div 14.1)

0 0 0

16.16.2 Ditto but for dumbwaiter No. 0 0 2 0 1 0 1

0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 95/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

Supply, install, test and commission (6W) Ceiling metallic


16.17 loudspeaker (Recessed) complete with wires , and all No. 0 0 0 0 0 0 0
needed accessories as shown on the drawings.

0 0 0

Supply, install, test and commission (10W) Ceiling


16.18 metallic loudspeaker wall mounted complete with wires , No. 0 0 0 0 0 0 0
and all needed accessories as shown on the drawings

0 0 0
16.19 Ditto but weather proof No. 0 0 0 0 0 0 0
0 0 0

Supply, install, test and commission Music Rack located


at control room at roof complete with wires, conduits ,
Amplifiers , power supply , back up batteries, AM/FM
digital tuner , DVD player, MP3 player , CD player , 0 0 0 0 0 0 0
16.20. LS
CasSette player , Portable UHF- Band Wireless
microphone (complet with receiver and transmitter) ,
microphone , and all needed accessories as shown on the
drawings

0 0 0
0 0 0

DIV#16 Total cost of this section Carried Forward To Summary 0 0 0

*** NOTE:-

Item overlooked in the bill of quantity but shown


in drawings, specification and schedules
necessary for the satisfactory completion of the
works may be priced hereunder.

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary - - -

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 96/2284


DIVISION # 1~16 / ALL DISCIP

MAIN DEWANIAH GUEST VILLA MOTHER VIILA ABDULL AZIZ

ITEM DIV UNIT PRICE (SR) B01 B02 B03 B04


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 97/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

1.10 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.10 see seprate BOQ for Div # 1 ( general requirments for BOQ LS 0 0 0 0 0

DIV#1 Total cost of this section Carried Forward To Summary - - - - -

2.00 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

2.30 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 0 7370 0 10652 0 7256 0 347 0
0 0 0 0 0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0 0 0 0 0
each, complete

0 0 0 0 0
2.3.2 Up to levels and around & above foundations. m3 0 2090 0 7941 0 112 0 217 0
0 0 0 0 0
Crushed aggregate base course, compacted to 100%
0 0 0 0 0
modified AASHTO density CBR ≥ 80%
0 0 0 0 0
2.3.3 250mm thick under slabs on grade m2 0 820 0 1510 0 1611 0 382 0
0 0 0 0 0
2.40 ANTI TERMITE 0 0 0 0 0
Refer to spesification # 2285 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 98/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
2.4.1 Termite control treatment for all vertical and L.S 0 1 0 1 0 1 0 1 0
horizontal areas complete in accordance with 0 0 0 0 0
specifications.

DIV#2 Total cost of this section Carried Forward To Summary - - - - -

3.00 DIV#3 CONCRETE WORKS

Plain concrete (grade 15), 15N/mm2 at 28 days cylinder


compressive strength, using portland cement, including all
3.10 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0 92 0 30 0 83 0 11 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0 36 0 61 0 94 0 15 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0 4 0 9 0 7 0 5 0


0 0 0 0 0
Cyclopean concrete; comprising of 50:50 plain concrete 0 0 0 0 0
and stone
0 0 0 0 0
3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0 6 0 7 0 10 0 1 0
0 0 0 0 0
Reinforced cast in situ concrete (grade 30), 30N/mm2
,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.20 including high tensile steel reinforcement grade 420Mpa 0 0 0 0 0 0 0 0 0
and mild steel reinforcement grade 280Mpa (Φ8mm); to

0 0 0 0 0

3.2.1 Foundations; (single, compound ) m3 0 238 0 27 0 176 0 42 0


0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 99/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

3.2.1.1 Foundations; (Raft , continous ) 0 156 0 78 0 207 0 5 0

0 0 0 0 0
3.2.2 Tie beams - Intermediate m3 0 0 0 83 0 0 0 34 0
0 0 0 0 0
3.2.3 Upper tie beams m3 0 56 0 83 0 108 0 25 0
0 0 0 0 0
3.2.4 Slabs on grade m3 0 136 0 242 0 340 0 126 0
0 0 0 0 0
3.2.5 Walls below slab on grade m3 0 74 0 143 0 50 0 0 0
0 0 0 0 0
3.2.6 Columns Below slab on grade m3 0 28 0 31 0 15 0 14 0
0 0 0 0 0
3.2.7 Water Tanks Slabs and Walls m3 0 194 0 93 0 160 0 118 0
0 0 0 0 0
3.2.8 Swimming pool Slabs and Walls m3 0 0 0 0 0 65 0 0 0
0 0 0 0 0
3.2.9 Car Park Roof Slab m3 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
Reinforced cast in situ concrete (grade 30), 30N/mm2
,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.30 and mild steel reinforcement grade 280Mpa (Φ8mm); to 0 0 0 0 0 0 0 0 0

0 0 0 0 0
3.3.1 Columns above slab on grade m3 0 202 0 76 0 221 0 23 0
0 0 0 0 0
3.3.2 Shear Walls , free standing walls above slab on Grade m3 0 154 0 132 0 180 0 0 0
0 0 0 0 0
3.3.3 Suspended solid slabs; including drop beams m3 0 550 0 535 0 961 0 103 0
0 0 0 0 0
Ribbed slabs;including hollow concrete blocks and hidden
3.3.4 beams -Ribs m2 0 252 0 0 0 0 0 0 0

0 0 0 0 0
3.3.5 Stairs (steps, flights and landing) m3 0 24 0 3 0 26 0 0 0
0 0 0 0 0
3.3.6 Beams m3 0 52 0 86 0 85 0 13 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 100/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
3.40 CONCRETE PROTECTION AND INSULATION 0 0 0 0 0 0 0 0 0

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers; 0 0 0 0 0
1.5 liters/m2
Supply, install and test of the liquid applied polyurethane
waterproofing; applied in two layers; 1.5 liters/m 2 0 0 0 0 0

0 0 0 0 0
3.4.1 To all structural elements below grade m2 0 1332 0 1682 0 2093 0 853 0
0 0 0 0 0
4mm thick torch applied SBS modified bituminous
polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and 0 0 0 0 0
specifications

0 0 0 0 0
3.4.2 To basement's walls - Vertical m2 0 1126 0 1383 0 605 0 0 0
3.4.2.1 Below slab on grade for basements -Horizontal 0 674 0 1213 0 1700 0 310 0
3.4.2.2 Water Tanks 0 950 0 395 0 360 0 294 0
3.4.2.3 Swimming pools 0 0 0 0 0 169 0 0 0
0 0 0 0 0
PVC water stop, web thickness (4-5) mm, complete as
detailed on drawings and as specified 0 0 0 0 0

0 0 0 0 0
3.4.5 To water tanks; 250mm wide mr 0 54 0 27 0 116 0 50 0
0 0 0 0 0

DIV#3 Total cost of this section Carried Forward To Summary - - - - -

4.00 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and


internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 101/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.10 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2 0 770 0 401 0 1369 0 0
and one layer of 150 mm concrete masoNo.y units 0 0 0 0 0
for external wall including reinforcement and 50 0 0 0 0 0
mm polyurethane foam insulation as specified in 0 0 0 0 0
the drawings & specifications:- 0 0 0 0 0
0 0 0 0 0
4.20 CMU walls Without Isolation 0 0 0 0 0
0 0 0 0 0
4.2.1 350 mm thick (CMU) block masoNo.y works to m2 0 0 0 128 0 0
internal / partition walls 0 0 0 0 0
0 0 0 0 0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0 665 0 333 0 0 0 0 0
internal / partition walls / Parapet 0 0 0 0 0
0 0 0 0 0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0 275 0 137 0 38 0 0
internal / partition walls / Parapet 0 0 0 0 0
0 0 0 0 0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0 1175 0 589 0 1943 0 611 0
internal / partition walls / Parapet 0 0 0 0 0
0 0 0 0 0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0 0 89 0 668 0 0
internal / partition walLS 0 0 0 0 0
0 0 0 0 0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0 800 0 0 1523 0 35 0
internal /partition walLS 0 0 0 0 0
0 0 0 0 0
4.30 Forming of Arch. Shape 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 102/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
4.3.1 Construction of block masonry works, to get m3 0 0 0 0 0
shape as per architectural design . 0 0 0 0 0
0 0 0 0 0
DIV#4 Total cost of this section Carried Forward To Summary - - - - -

5.10 DIV#5 METAL WORKS LS 0 0 0 0 0


NA

DIV#5 Total cost of this section Carried Forward To Summary - - - - -

6.10 DIV#6 WOOD & PLASTIC LS 0 0 0 0 0


NA

DIV#6 Total cost of this section Carried Forward To Summary - - - - -

7.10 DIV#7 THERMAL & MOISTURE

7.10 Waterproofing

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 103/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0 675 0 721 0 991 0 38 0
moisture protection and waterproofing consisting 0 0 0 0 0
of 40 mm smooth finish sloping screed over roof 0 0 0 0 0
slab, 3+3 modified bituminous waterproofing 0 0 0 0 0
membrane over primer, including 50mm thick 0 0 0 0 0
extruded polystyrene boards 35KG/m3, separation 0 0 0 0 0
layer 140KG/m2 and finish tiles 300x300x30mm to 0 0 0 0 0
horizontal and vertical areas as shown and 0 0 0 0 0
specified in the drawings and specifications. 0 0 0 0 0
0 0 0 0 0
7.1.2 Ditto, but without roof boards along parapet LM 0 595 0 378 0 345 0 163 0
vertical up-stand 150 mm above from roof finish 0 0 0 0 0
level, including aluminum flashing 100 mm wide 0 0 0 0 0
and 1.5 mm thick at termination level as specified 0 0 0 0 0
in the drawings and specifications. 0 0 0 0 0
0 0 0 0 0
Wet Areas (Bath Rooms & Kitchens) 0 0 0 0 0
0 0 0 0 0
7.1.3 Supply, install and test of the liquid applied m2 0 250 0 114 0 423 0 40 0
polyurethane waterproofing type (black P.U.) to be 0 0 0 0 0
applied in two (2) layers 1.5 liters/m2 over the 0 0 0 0 0
entire flat areas including vertical and horizontal 0 0 0 0 0
penetrations, drains and to be self-terminated at 0 0 0 0 0
minimum 100 mm above the floor finish level 0 0 0 0 0
including separation layer, screed protection (or) 0 0 0 0 0
equivalent and all necessary components to 0 0 0 0 0
complete ready facility as specified. 0 0 0 0 0
0 0 0 0 0
Planter Boxes & Green area 0 0 0 0 0
Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 104/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4 0 0 0 0 0
Swimming Pool & Water Tanks 0 0 0 0 0
0 0 0 0 0
7.1.3 Supply, install and test of the liquid applied m2 0 310 0 154 0 520 0 98 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 105/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Cement based proofing 0 0 0 0 0
applied in two (2) layers 1.5 liters/m2 over the 0 0 0 0 0
entire areas including vertical and horizontal 0 0 0 0 0
penetrations, drains and to be self-terminated 0 0 0 0 0
equivalent and all necessary components to 0 0 0 0 0
complete ready facility as specified. 0 0 0 0 0

DIV#7 Total cost of this section Carried Forward To Summary - - - - -

8.10 DIV#8 DOORS & WINDOWS

Supply and installation of complete doors &


windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.10 Basement Floor


Excluded- At this stage

8.20 Ground Floor


Excluded- At this stage

8.50 First Floor


Excluded- At this stage

8.60 Penthouses
Excluded- At this stage

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 106/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

DIV#8 ALUMINUM & GLAZING INCLUDING WINDOWS SHUTTERS


(separate price from main windows units)

Supply and installation of electric motor operated windows


roller shutters (unless otherwise noted), complete with all its
necessary accessories to complete ready to operate facility
with as specified in the drawings and windows schedule, as
follows:

8.70 Windows Type / Main Dewaniah B-01:


Excluded- At this stage

8.80 Windows Type / Guest Villa B-02:


Excluded- At this stage

8.90 Windows Type / Mother Villa B-03:


Excluded- At this stage

8.10 Windows Type / Abdulaziz Villa B-04:


Excluded- At this stage

8.11 Windows Type / Abdulaziz Douplex B-05:


Excluded- At this stage

8.12 Windows Type / Club House B-06:


Excluded- At this stage
8.13 Windows Type / Majid & Nasir Villa B-07:
Excluded- At this stage

8.14 Windows Type / Majid & Nasir Diwaniah B-08:


Excluded- At this stage

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 107/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
8.15 Windows Type / Adel Villa B-09:
Excluded- At this stage

8.16 Windows Type / Mohammed Villa B-10:


Excluded- At this stage

8.17 Windows Type / Abdulillah & Ibrahim Villa B-11:


Excluded- At this stage

8.18 Windows Type / Diewaniah Ibrahim B-12:


Excluded- At this stage

DIV#8 Total cost of this section Carried Forward To Summary - - - - -

9.10 DIV#9 FINISHES

Plastering Works

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0 2360 0 986 0 1643 0 698 0


0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 108/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
9.1.2 Plastering to walls internal sides. m2 0 4400 0 1845 0 7858 0 738 0
0 0 0 0 0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0 660 0 275 0 797 0 21 0
(Painted spaces only) 0 0 0 0 0
0 0 0 0 0
9.20 Ceilings Finishes 0 0 0 0 0
0 0 0 0 0
Supply and installation of ceiling finishing with 0 0 0 0 0
all the necessary materials and components as 0 0 0 0 0
indicated in the drawings and specifications:- 0 0 0 0 0
0 0 0 0 0
Inside the building 0 0 0 0 0
0 0 0 0 0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0 800 0 400 0 400 0 400 0
R.C slab. (color as to be approved by the client 0 0 0 0 0
or client site representative) To store and stairs . 0 0 0 0 0
0 0 0 0 0
9.2.2 Paint on Concrete m2 0 200 0 100 0 100 0 100 0
0 0 0 0 0
0 0 0 0 0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0 200 0 100 0 100 0 100 0
0 0 0 0 0
9.2.12 Moisture resistant gypsum board with paint for wet area m2 0 200 0 100 0 100 0 100 0
0 0 0 0 0
0 0 0 0 0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0 100 0 50 0 50 0 50 0
Kitchens 0 0 0 0 0
0 0 0 0 0
Outside the building 0 0 0 0 0
Excluded- At this stage 0 0 0 0 0
9.2.15 EF09 WOOD TRELLIS

Wall Finishes 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 109/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Excluded- At this stage 0 0 0 0 0
0 0 0 0 0
9.30 External Walls Surfaces 0 0 0 0 0
Excluded- At this stage 0 0 0 0 0
0 0 0 0 0
GRC Panels 0 0 0 0 0
Excluded- At this stage 0 0 0 0 0
0 0 0 0 0
9.40 Internal Walls Surfaces 0 0 0 0 0
0 0 0 0 0
9.4.1 Paint the interior walls m2 0 400 0 400 0 400 0 400 0
0 0 0 0 0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0 200 0 200 0 200 0 200 0
only for Maids bathrooms 0 0 0 0 0

0 0 0 0 0
9.50 Glass Walls 0 0 0 0 0
Excluded- At this stage 0 0 0 0 0
0 0 0 0 0
9.60 Floor Finishes 0 0 0 0 0
0 0 0 0 0
Supply and installation of floor finishing with 0 0 0 0 0
skirting and all the necessary materials and 0 0 0 0 0
components as indicated in the drawings and 0 0 0 0 0
specifications:- 0 0 0 0 0
Only for Maids , stores 0 50 0 50 0 50 0 50 0
9.6.1 VITRIFIED PORCELAIN TILES (300*300*8)mm m2 0 50 0 50 0 50 0 50 0
0 0 0 0 0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0 50 0 50 0 50 0 50 0
(300*300*8)mm 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
9.6.16 100 mm Concrete with epoxy paint layer m2 0 50 0 50 0 50 0 50 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 110/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
9.70 Stairs Finishes 0 0 0 0 0
Only for service staires 0 0 0 0 0
Saudi Binanco Granite - THREAD 30mm 0 0 0 0 0
THICK)/RISER 20MM THICK price to include 0 0 0 0 0
grooves for non-slip material and nose forming as 0 0 0 0 0
follows: 0 0 0 0 0
0 0 0 0 0
9.7.1 for Service Staircase L.M 0 0 30 0 180 0 0 0
0 0 0 0 0

9.7.19 Main Entrance 0 0 0 0 0


Excluded- At this stage

DIV#9 Total cost of this section Carried Forward To Summary - - - - -

10.10 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is
incoporated in related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage

10.20 Toilet Accessories


Excluded- At this stage

10.30 MISCELLANEOUS

Stair & The Balconies and Windows Handrail

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 111/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

External Balconies
Excluded- At this stage

Internal Stair

10.3.3 Handrail to external stairs


Excluded- At this stage
10.3.4 Handrail to internal stairs LM 0 0 0 10 0 50 0 0 0
for service stair cases 0 0 0 0 0

Ladder 0 0 0 0 0
0 0 0 0 0
10.3.5 Internal metal ladder Radius 1 meter and 0.93 width 0 0 0 0 0

to connect between laundry /iron and maids lobby


0 0 0 0 0
complete with paint finish

0 0 0 0 0
10.3.6 PVC COATED STEEL LADDER RUNGS for water tanks No. 0 2 0 1 0 2 0 1 0
To suit water tank - HIGHT 3.3 : 3.72 0 0 0 0 0
0 0 0 0 0
Manhole Covers 0 0 0 0 0
0 0 0 0 0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0 2 0 1 0 2 0 1 0
for water tanks - stone excluded on;y cover 0 0 0 0 0

Master Key System 0 0 0 0 0


Excluded- At this stage

DIV#10 Total cost of this section Carried Forward To Summary - - - - -

11.10 DIV#11 EQUIPMENTS 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 112/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
NA

DIV#11 Total cost of this section Carried Forward To Summary - - - - -

12.10 DIV#12 FURNITURE 0 0 0 0 0


NA

DIV#12 Total cost of this section Carried Forward To Summary - - - - -

13.10 DIV#13 SPECIAL CONSTRUCTIONS

13.10 Sky Light


Excluded- At this stage

13.20 Fountains Works


Excluded- At this stage

13.30 SWIMMING POOL FINISH


Excluded- At this stage

13.40 SAFETY HANDRAIL PANELS


Excluded- At this stage

DIV#13 Total cost of this section Carried Forward To Summary - - - - -

14.10 DIV#14 CONVEYING SYSTEM

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 113/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

14.10 LIFT / Private House & Dumpwaiter


Excluded- At this stage

DIV#14 Total cost of this section Carried Forward To Summary - - - - -

15.10 DIV#15 DIVISION 15 - MECHANICAL

15.10 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0 696 0 252 0 650 0 18 0
0 0 0 0 0
15.1.1.2 25 mm outside diameter pipe LM 0 148 0 72 0 270 0 12 0
0 0 0 0 0
15.1.1.3 32 mm outside diameter pipe LM 0 310 0 35 0 430 0 21 0
0 0 0 0 0
15.1.1.4 40 mm outside diameter pipe LM 0 152 0 114 0 295 0 12 0
0 0 0 0 0
15.1.1.5 50 mm outside diameter pipe LM 0 126 0 137 0 164 0 34 0
0 0 0 0 0
15.1.1.7 80 mm outside diameter pipe LM 0 24 0 6 0 8 0 6 0
0 0 0 0 0
Isolation Valves 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 114/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0 0 0 0 0
complete with all accessories and fittings, all as
specified as shown drawings.
0 0 0 0 0
Gate Valve 0 0 0 0 0
15.1.1.14 Gate vlave Ø 25 mm no 0 8 0 2 0 5 0 0 0
15.1.1.15 Gate vlave Ø 32 mm no 0 20 0 0 0 16 0 2 0
15.1.1.16 Gate vlave Ø 40 mm no 0 8 0 4 0 4 0 2 0
15.1.1.17 Gate vlave Ø 50 mm no 0 16 0 4 0 8 0 2 0
15.1.1.18 Gate vlave Ø 90 mm no 0 8 0 2 0 0 0 2 0
0 0 0 0 0
Concealed Valve 0 0 0 0 0
15.1.1.19 Concealed valve Ø 25 mm no 0 8 0 0 0 12 0 0 0
15.1.1.20 Concealed valve Ø 32 mm no 0 20 0 0 0 25 0 0 0
15.1.1.21 Concealed valve Ø 40 mm no 0 8 0 0 0 4 0 0 0
0 0 0 0 0
15.1.2 Electric Water Heaters 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
0 0 0 0 0
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings ."by Saudi
Ceramic or equivalent as per owner instructions"

0 0 0 0 0
15.1.2.2 EWH-2 (50 Liter) No. 0 24 0 0 0 37 0 1 0
0 0 0 0 0
15.1.2.3 EWH-3 (80 Liter ) No. 0 18 0 2 0 4 0 0 0
0 0 0 0 0
15.1.2.4 EWH-4 (100 Liter) No. 0 12 0 2 0 0 0 1 0
0 0 0 0 0
15.1.3 Domestic Cold water tank 0 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 115/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0 0 0 0 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0 0 0 0 0
15.1.3.1 WT- ( 8000 L ) No. 0 4 0 1 0 2 0 1 0
0 0 0 0 0
15.1.4 Ground Water Tank Accessories 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Level control float switches with electric connections,
15.1.4.4 complete with but not limited to over flow alarm bell LM 0 8 0 2 0 4 0 2 0
and all necessary works

0 0 0 0 0
Bronze equilibrium ball float valve, installed connected
15.1.4.5 and tested complete with accessories as specified as LM 0 2 0 1 0 2 0 1 0
shown on drawings.

0 0 0 0 0
15.1.4.6 Vent. 65 mm diameter. No. 0 2 0 1 0 2 0 1 0
0 0 0 0 0
15.1.5 Pumps 0 0 0 0 0 0 0 0 0
0 0 0 0 0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0 0 0 0 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0 0 0 0 0
ancillary work as specified nd as shown on
drawings."Grundfos ,KSB , Aurora or equivalent as per
owner instructions"

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0 4 0 1 0 2 0 1 0
0 0 0 0 0
15.1.6 Domestic Water Booster Set 0 0 0 0 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 116/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating valves PN 16, lug and , strainer PN
16, flexible connections, concrete inertia pad, house
pad, vibration eliminator pad, low level control float
switches, pressure switch dry run protection and 0 0 0 0 0
controls all supplied from pump manufacturer
diaphragm tank (s), food quality synthetic rubber
membrane, steel painted body, working pressure 10
bars with isolating valve and pressure gauge, electric
connections, wiring and accessories all as specified and
shown on the drawings. "Grundfos ,KSB , Aurora or
equivalent as per owner instructions"

0 0 0 0 0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0 0 0 1 0 1 0 0 0
0 0 0 0 0
15.1.6.2 BP-2 (35 GPM /43 FT) Set 0 4 0 0 0 1 0 1 0
0 0 0 0 0
15.1.6.3 BP-3 (55 GPM /43 ft) Set 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.20 FIRE FIGHTING SYSTEM 0 0 0 0 0 0 0 0 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0 0 0 0 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0 0 0 0 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0 20 0 6 0 18 0 2 0


0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 117/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0 0 0 0 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0 12 0 2 0 12 0 0 0


0 0 0 0 0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0 0 0 0 0
per owner instructions"

15.2.3 Fire blanket No. 0 12 0 2 0 12 0 1 0


0 0 0 0 0
15.30 PLUMBING FIXTURE APPLIANCES 0 0 0 0 0 0 0 0 0
0 0 0 0 0
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains
0 0 0 0 0
including adapters, branches, tees, valves, supports
from galvanized steel, brackets, hangers ,shelves,
siphon, terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications
0 0 0 0 0
Water Closet

Western type vitreous china water cloSet complete


with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0 0 0 0 0
connection as specified.

WC-01 ( Supply and install ) for Maids rooms (ideal


15.3.1.1 No. 0 0 0 0 0 8 0 0 0
standard or equivlant)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 118/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
install only ,connection and testing wall mounted WC
complete with but not limited to concealed
tank with actuator flush panel or pneumatic
push button for washdown wall-hung toilets and
Chrome hand spry Include adjustable wall bracket with
min. 1.2 m hose
System shall fit within minimum 51
⁄2" (146 mm) framing wall or plumbing chase, with
steel framing members Framing members
should be capable of supporting 400 kg load without
damage to the wall. Water
supply shall have minimum flow
pressure of 2 PSI (0.01 MPa). The toilet bowl
0 0 0 0 0
shall be a third party listed low-consumption
1.6/0.8 GPF (6/3 LPF) dualflush
2-hole wall-hung type. The carrier frame
shall be adjustable for bowl rim heights from
15" to 19" (381 to 483 mm). Actuator flush
panels shall be diecast zinc, molded plastic or
fabricated stainless steel and plated to
preserve material integrity. All components
shall be compliant with applicable codes and
product standards.

WC-02 Install Only ( Fixtures Purchase by Client -Part


15.3.1.2 No. 0 0 0 12 0 20 0 3 0
of ID )

0 0 0 0 0
Lavatories
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer and 800x900mm wall 0 0 0 0 0
mirror with chamfered edge including all the necessary
fittings & accessories and approved by the owner .

( Lav-01 ) ( Supply and install for Maids rooms ( ideal


15.3.2.1 standard inclusive of water mixer grohe or equivlant ) No. 0 0 0 0 0 12 0 0 0

Supply ,install ,connection and testing for recessed


mounted Lavatories complete including wash basin 0 0 0 0 0
mixer with but not limited to hangers support
(galvanized steel made)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 119/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
15.3.2.2 ( Lav-02 ) Install Only ( Fixtures Purchase by Client No. 0 0 0 27 0 37 0 4 0
-Part of ID )

Bathtub
Supply and install bathtub ,complete, including water
feed, waste and vent branch piping works to mains
including adapters, branches, tees, valves, mixer,
supports, brackets, hangers , siphon ..etc. all as
specifications, drawings and water consumption 0 0 0 0 0
rationalization specifications all model must approved
from owner representative and consultant. only as
required for fixture installation and to wall connection .
BT-02 Install ony ( Fixture Purchase by Client -Part of
15.3.3.2 No. 0 8 0 0 0 9 0 0 0
ID )
0 0 0 0 0
kitchen sink 0 0 0 0 0
Excluded- At this stage 0 0 0 0 0
0 0 0 0 0
Shower Hand mixer 0 0 0 0 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (as per owner 0 0 0 0 0
representative and consultant.)
0 0 0 0 0
15.3.9.1 SH-01 (sypply and install) grohe Type or equivalent . No. 0 0 0 0 0 6 0 0 0
0 0 0 0 0
15.3.9.2 SH-02 Install Only ( Fixtures Purchase by Client -Part of No. 0 0 0 6 0 15 0 0 0
ID )
0 0 0 0 0
15.40 STORMWATER AND DRAINAGE SYSTEM 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.4.1 Pipework 0 0 0 0 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 120/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0 0 0 0 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0 0 0 0 0
15.4.1.1 50 mm diameter pipe LM 0 60 0 19 0 54 0 15 0
0 0 0 0 0
15.4.1.2 80 mm diameter pipe LM 0 346 0 25 0 185 0 20 0
0 0 0 0 0
15.4.1.3 110 mm diameter pipe LM 0 250 0 182 0 1000 0 70 0
0 0 0 0 0
15.4.1.4 160 mm diameter pipe LM 0 0 0 58 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
Floor Drain 0 0 0 0 0
0 0 0 0 0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0 0 0 0 0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0 0 0 0 0
15.4.1.5 FD-80 mm outlet diameter No. 0 44 0 16 0 76 0 7 0
0 0 0 0 0
0 0 0 0 0
Floor Cleanout 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 121/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0 0 0 0 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0 0 0 0 0
15.4.1.7 FCO- 110mm No. 0 14 0 2 0 28 0 3 0
0 0 0 0 0
15.4.1.8 WCO- 110mm No. 0 0 0 11 0 38 0 0 0
0 0 0 0 0
Trench Drain 0 0 0 0 0
0 0 0 0 0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as 0 0 0 0 0
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0 0 0 0 0 8 0 0 0


Inspection room 0 0 0 0 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and No. 0 0 0 9 0 0 0 0 0
as shown on drawings .

0 0 0 0 0
Gully trap 0 0 0 0 0
Constructing , connecting and testing Gully trap
complete with heavy duty cast iron cover and all other
accessories all as specifications and as shown on
15.4.1.9.2 No. 0 0 0 0 0 0 0 0 0
drawings

0 0 0 0 0
Submersible Pumps 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 122/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0 0 0 0 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-01 (35 GPM / 18 FT )
15.4.1.10 set 0 0 0 0 0 0 0 0 0

0 0 0 0 0
Roof Drain 0 0 0 0 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0 0 0 0 0
with accessories all as specified and shown on drawing.

0 0 0 0 0
15.4.1.15 RD, 110mm outlet diameter No. 0 14 0 9 0 14 0 6 0
0 0 0 0 0
15.4.1.16 RD, 75mm outlet diameter No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Down spout 0 0 0 0 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0 0 0 0 0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0 6 0 9 0 6 0 6 0


0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
Roof Vent Cap 0 0 0 0 0
0 0 0 0 0
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner 0 0 0 0 0
instructions"

15.4.1.19 Type RVC, 110 mm diameter pipe No. 0 24 0 17 0 18 0 4 0


0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 123/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

15.50 HVAC SYSTEM 0 0 0 0 0 0 0 0 0


BUILDER'S WORK RELATED TO MECHANICAL
0 0 0 0 0
WORKS
0 0 0 0 0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0 2 0 1 0 1 0 1 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0 0 0 0 0
LABELING AND IDENTIFYING 0 0 0 0 0
0 0 0 0 0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0 2 0 1 0 1 0 1 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0 0 0 0 0
15.5.3 AIR CONDITIONERS UNITS 0 0 0 0 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 124/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission Packaged roof
mounted air-condition unit, (HEAT PUMP TYPE)
according to the following specifications : Heavy gauge
galv. Steel sheet, with electrostatic powder paint of
epoxy coating finish. Double skin unit casing with
suitable thermal insulation, Weather proof, Hermetic
sealed scroll compressors Refrigerant , Micro processor
controller, Return fan and supply fan, Aluminum Flat
Filter, Economizer section, Mixing box with
automatically operated fresh air damper, External
overload protections for all compressors and circuit
breaker for the unit. Evaporator coil and condenser coil
15.5.3.1 made of copper tubes and aluminum fins, Thermal 0 0 0 0 0 0 0 0 0
expansion valve, Gas control, Filter driers, Sight glass,
Solenoid valves; High and low pressure cutouts; Oil
pressure switches; Air and fire dampers. Drain system
for condensate water Anti vibration pads; Concrete
bases; Inside air temperature controlling according to
ASHRAE standards and All electrical wiring and
conduits required, Kinetic Float Base, Equipment
capacities as tabulated on the drawings. By Daikin
manuf. or equivelant

15.5.3.1.4 PAC-04 6TR No. 0 0 0 2 0 0 0 0 0


0 0 0 0 0
15.5.3.1.5 PAC-05 7.5TR No. 0 0 0 2 0 0 0 0 0
0 0 0 0 0
15.5.3.1.6 PAC-06 8.5TR No. 0 0 0 0 0 0 0 3 0
0 0 0 0 0
15.5.3.1.7 PAC-07 - 10TR No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.3.1.9 PAC-09 - 15TR No. 0 0 0 2 0 0 0 0 0
0 0 0 0 0
15.5.3.1.10 PAC-10 24TR No. 0 0 0 2 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 125/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
power connections between the isolator switch and the
15.5.3.2 outdoor unit, vibration isolators, hangers for the indoor 0 0 0 0 0 0 0 0 0
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Concealed Type - for Vills 0 0 0 0 0


15.5.3.2.1.1 FCU-01 - 1.5TR 0 0 0 0 0 0 0 2 0
0 0 0 0 0
15.5.3.2.1.2 FCU-02 - 2TR 0 4 0 2 0 0 0 0 0
0 0 0 0 0
15.5.3.2.1.3 FCU-03 - 2.5TR 0 4 0 0 0 0 0 0 0
0 0 0 0 0
15.5.3.2.1.4 FCU-04 - 3TR 0 4 0 0 0 0 0 0 0
0 0 0 0 0
15.5.3.2.1.5 FCU-05 - 3.5TR 0 8 0 0 0 0 0 1 0
0 0 0 0 0
15.5.3.2.1.6 FCU-06 - 4TR 0 8 0 0 0 0 0 0 0
0 0 0 0 0
15.5.3.2.1.8 FCU-08 - 5TR 0 8 0 0 0 0 0 0 0
0 0 0 0 0
Cassette units - for Kitchens 0 0 0 0 0
0 0 0 0 0
15.5.3.2.1.9 CDX-01 -1.5TR 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.3.2.1.10 CDX-02 - 2TR 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.3.2.1.11 CDx-03 -2.5TR 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Split Wall mounted Type - For service Drivers , 0 0 0 0 0
Maid stores .. 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 126/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
15.5.3.2.1.12 WDX-01 -1TR 0 4 0 0 0 0 0 2 0
0 0 0 0 0
15.5.3.2.1.13 WDX-02 -1.5TR 0 16 0 1 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
15.5.3.3 Refrigeration Unit Type 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply, install, test and commission refrigeration unit
type with appropriate compressors, evaporators,
refrigeration gas and all components and accessories. 0 0 0 0 0

0 0 0 0 0
15.5.3.3.1 Ref. ROU-01 / RIU-01 -Ref. ROU-B02-1 / RIU-B02-1 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.3.3.2 Ref. ROU-02 / RIU-02 -Ref. ROU-B02-2 / RIU-B02-2 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0 0 0 0 0 0 0 0 0

0 0 0 0 0
Supply, install, test and commission centrifugal in line/
roof mounted (Roof Top Type) belt drive exhaust fan
with external motor installation for kitchen hoods, fans
shall be able to operate for no less than one hour at
high temperature , complete with steel bases, steel
box, frames, rubber pads, sealers for leakage, access
panels , flexible connections with ducts, guard screens,
back draft damper with all fixing, support, grease 0 0 0 0 0
drain , and all required accessories and all required
accessories for proper installation and as per specs &
dwgs. "suadi fans , greenheck, ASEM or equivalent as
per owner instructions"

15.5.4.1 HEF-B01-G-01 No. 0 0 0 0 0 0 0 0 0


0 0 0 0 0
15.5.4.2 HEF-B02-B-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.4 HEF-B02-B-02 No. 0 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 127/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
15.5.4.4.1 HEF-B02-B-03 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.5 HEF-B03-B-01 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.6 HEF-B03-G-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.7 HEF-B03-FR-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.8 HEF-B04-B-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.9 HEF-B04-G-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.10 HEF-B04-G-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.11 HEF-B07-B-01 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.12 HEF-B07-B-02 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.13 HEF-B07-B-03 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.14 HEF-B09-B-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.14.1 HEF-B10-B-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.14.2 HEF-B10-B-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.15 HEF-B11-B-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.16 HEF-B11-B-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.17 HEF-B11-B-03 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.18 HEF-B11-B-04 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.19 HEF-B11-B-05 No. 0 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 128/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0 0 0 0 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

Fan Section (belt driven) 0 0 0 0 0


0 0 0 0 0
15.5.4.20 MAF-B02-B-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.21 MAF-B02-B-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.22 MAF-B07-B-01 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.23 MAF-B07-B-02 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.24 MAF-B07-B-03 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.25 MAF-B11-B-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.26 MAF-B11-B-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.27 FAF-B01-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.30 FAF-B03-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.31 FAF-B04-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.32 FAF-B05-01 No. 0 2 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.33 FAF-B05-02 No. 0 2 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 129/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
15.5.4.34 FAF-B07-B-01 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.35 FAF-B07-01 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.36 FAF-B07-02 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.37 FAF-B08-01 No. 0 0 0 0 0 0 0 1 0
0 0 0 0 0
15.5.4.38 FAF-B09-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.39 FAF-B10-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.40 FAF-B10-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.41 FAF-B11-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.42 FAF-B11-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.43 FAF-B12-G-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0 0 0 0 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0 0 0 0 0
0 0 0 0 0
15.5.4.45 EXF-B01-B-02 ( Roof top ) No. 0 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 130/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
15.5.4.46 EXF-B01-B-03( Roof top ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.47 EXF-B01-G-01( Roof top ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.48 EXF-B01-G-02( Roof top ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.52 EXF-B02-B-01( Roof top ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.53 EXF-B02-B-02( Roof top ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.54 EXF-B02-B-03( IN LINE ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
15.5.4.55 Ditto but Centrifugal in line fan 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.56 EXF-B02-G-02( IN LINE ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.57 EXF-B02-G-03( IN LINE ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.58 EXF-B02-G-04( IN LINE ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.59 EXF-B02-G-05( IN LINE ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.60 EXF-B02-G-06( IN LINE ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.61 EXF-B02-G-07( IN LINE ) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.62 EXF-B06-B-01 No. 0 0 0 1 0 0 0 0 0
0 0 0 0 0
15.5.4.63 EXF-B06-G-01 No. 0 0 0 2 0 0 0 0 0
0 0 0 0 0
15.5.4.64 EXF-B06-G-02 No. 0 0 0 2 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 131/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
15.5.4.65 EXF-B06-G-03 No. 0 0 0 2 0 0 0 0 0
0 0 0 0 0
15.5.4.66 EXF-B06-G-04 No. 0 0 0 2 0 0 0 0 0
0 0 0 0 0
15.5.4.67 EXF-B07-B-01 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.68 EXF-B07-B-02 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.69 EXF-B07-B-03 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.70 EXF-B07-B-04 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.71 EXF-B07-B-05 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.72 EXF-B07-F-01 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.4.73 EXF-PAC-B07-01(INLINE) No. 0 0 0 0 0 2 0 0 0
0 0 0 0 0
15.5.4.75 EXF-B08-G-01(INLINE) No. 0 0 0 0 0 0 0 1 0
0 0 0 0 0
15.5.4.76 EXF-PAC-B08-01(INLINE) No. 0 0 0 0 0 0 0 1 0
0 0 0 0 0
15.5.4.77 EXF-PAC-B08-02(INLINE) No. 0 0 0 0 0 0 0 1 0
0 0 0 0 0
15.5.4.78 EXF-PAC-B08-03(INLINE) No. 0 0 0 0 0 0 0 1 0
0 0 0 0 0
15.5.4.82 EXF-PAC-B11-01(INLINE) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.83 EXF-B12-G-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.84 EXF-B12-G-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 132/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
15.5.4.85 EXF-PAC-B12-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.86 EXF-PAC-B12-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.90.1 AEX-B02-01 NO 0 0 0 0 0 0 0 0 0
15.5.4.90.2 AEX-B04-02 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0 0 0 0 0
greenheck, ASEM or equivalent as per owner
instructions"
0 0 0 0 0
15.5.4.91 CEX-01 No. 0 24 0 0 0 0 0 2 0
15.5.4.92 CEX-02 No. 0 24 0 0 0 0 0 1 0
0 0 0 0 0
Supply, install test & commission air curtain all
required accessories as per specs and schedule . 0 0 0 0 0

0 0 0 0 0
15.5.4.93 AC-01 No. 0 0 0 3 0 0 0 1 0
15.5.4.94 AC-02 No. 0 0 0 1 0 0 0 0 0
0 0 0 0 0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0 0 0 0 0
greenheck, ASEM or equivalent as per owner
instructions"
0 0 0 0 0
15.5.4.95 WEX-B02-01 NO 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.96 WEX-B03-01 NO 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.97 WEX-B04-01 NO 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.4.98 WEX-B06-01 0 0 0 2 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 133/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

15.5.5 Condensate Pipework 0 0 0 0 0 0 0 0 0


0 0 0 0 0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick 0 0 0 0 0
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0 0 0 0 0
15.5.5.1 25 mm outside diameter pipe LM 0 504 0 14 0 315 0 45 0
0 0 0 0 0
15.5.5.4 50mm outside diameter pipe LM 0 0 0 60 0 15 0 30 0
0 0 0 0 0
15.5.6 Ductwork 0 0 0 0 0 0 0 0 0
0 0 0 0 0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0 4144 0 6398 0 10303 0 2281 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 134/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0 0 0 0 0 3 0 0 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0 0 0 0 0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0 0 0 0 0 3 0 0 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0 0 0 0 0
Supply ,install ,connect ,test and commission
protection, aluminum cladding for external duct,
15.5.6.4 kg 0 0 1510 0 0 181 0
complete with but not limited to all acessories , flow
indicators, labels, color code stickers,….etc
0 0 0 0 0
15.5.7 Ductwork Insulation 0 0 0 0 0 0 0 0 0
0 0 0 0 0

Supply, install, connect, test and commission


Fiberglass blanket duct insulation for supply, fresh air
and return ductwork, Fiberglass insulation 25mm thick
density 24kg/m3, factory laminated to a reinforced foil
15.5.7.1 Kraft vapour barrier facing covered with canvas fabric m2 0 698 0 967 0 1680 0 354 0
wrap and two layers of fungus resistant mastic,
installed connected and tested complete including self
adhesive fixing pins, sealing tape, wire banding and
accessories all as specified and shown on drawings.

0 0 0 0 0
15.5.7.2 Ditto but with thikness 50 mm and 48 kg/m³ desity m2 0 0 472 0 0 47 0
0 0 0 0 0
15.5.8 Duct Acoustic Inner Liner 0 0 0 0 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 135/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, connect, test and commission Duct


acoustic inner liner Rubber insulation thickness 13 mm
fixed with fire resistant adhesive and mechanical
15.5.8.1 LS 0 2 0 1 0 1 0 1 0
fasteners, installed, connected and tested complete
with accessories, to meet NC as specified and shown
on drawings.

0 0 0 0 0
15.5.9 Air Diffusers, Registers, and Grilles 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply, install, connect, test and commission, Supply
Linear Slotting Diffuser as per drawings, complete with
volume dampers, insulated plenum box and including 0 0 0 0 0
all accessories to complete the work.. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

0 0 0 0 0
15.5.9.1 SLD - 1 LM 0 0 0 0 0 13 0 0 0
0 0 0 0 0
15.5.9.2 SLD - 2 LM 0 0 0 0 0 29 0 0 0
0 0 0 0 0
15.5.9.3 SLD - 3 LM 0 12 0 0 0 19 0 18 0
0 0 0 0 0
15.5.9.4 SLD - 4 LM 0 16 0 17 0 64 0 6 0
0 0 0 0 0
15.5.9.5 SLD - 5 LM 0 136 0 0 0 108 0 0 0
0 0 0 0 0
15.5.9.6 SLD - 6 LM 0 8 0 36 0 0 0 20 0
0 0 0 0 0
15.5.9.7 SLD - 7 LM 0 0 0 16 0 16 0 0 0
0 0 0 0 0
15.5.9.8 SLD - 8 LM 0 0 0 0 0 4 0 0 0
0 0 0 0 0
Supply, install, connect, test and commission,Return
and installation of return Linear Slotting Diffuser as per
drawings, complete with volume dampers, insulated
plenum box and including all accessories to complete 0 0 0 0 0
the work.

15.5.9.9 RLD - 1 LM 0 0 0 0 0 13 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 136/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
15.5.9.10 RLD - 2 LM 0 0 0 0 0 19 0 0 0
0 0 0 0 0
15.5.9.11 RLD - 3 LM 0 12 0 0 0 19 0 18 0
0 0 0 0 0
15.5.9.12 RLD - 4 LM 0 16 0 57 0 79 0 6 0
0 0 0 0 0
15.5.9.13 RLD - 5 LM 0 132 0 32 0 104 0 0 0
0 0 0 0 0
15.5.9.14 RLD - 6 LM 0 8 0 36 0 0 0 20 0
0 0 0 0 0
15.5.9.15 RLD - 7 LM 0 0 0 42 0 16 0 0 0
0 0 0 0 0
15.5.9.16 RLD - 8 LM 0 0 0 0 0 4 0 0 0
0 0 0 0 0
Supply, install, connect, test and commission, powder
coated aluminum register air grill with opposed blade
dampers , color to be selected by the Engineer,
including connections to ductwork with plenum box
0 0 0 0 0
and flexible duct, volume damper for balancing
purposes, mounting, fixings and all required
accessories as per specs and drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0 0 0 0 0
15.5.9.17 SR-01 No. 0 0 0 0 0 0 0 0 0

Diito as above But Return Rabeea, GGC, Beta, or


equivalent as per owner instructions" 0 0 0 0 0

15.5.9.18 RR-01 No. 0 0 0 0 0 0 0 0 0


0 0 0 0 0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0 0 0 0 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0 0 0 0 0
15.5.9.19 EG-01 No. 0 0 0 24 0 16 0 6 0
0 0 0 0 0
15.5.9.20 EG-02 No. 0 0 0 0 0 6 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 137/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0 0 0 0 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
15.5.9.46 EAL-B02-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.9.48 EAL-B02-04 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.9.52 EAL-B06-01 No. 0 0 0 6 0 0 0 0 0
0 0 0 0 0
15.5.9.53 EAL-B06-02 No. 0 0 0 2 0 0 0 0 0
0 0 0 0 0
15.5.9.54 EAL-B06-03 No. 0 0 0 1 0 0 0 0 0
0 0 0 0 0
15.5.9.55 EAL-B07-01 No. 0 0 0 0 0 4 0 0 0
0 0 0 0 0
15.5.9.58 EAL-B07-04 No. 0 0 0 0 0 1 0 0 0
0 0 0 0 0
15.5.9.59 EAL-B07-05 No. 0 0 0 0 0 2 0 0 0
0 0 0 0 0
15.5.9.60 EAL-B08-01 No. 0 0 0 0 0 0 0 3 0
0 0 0 0 0
15.5.9.61 EAL-B08-02 No. 0 0 0 0 0 0 0 1 0
0 0 0 0 0
15.5.9.63 EAL-B11-01 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.9.64 EAL-B11-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.9.65 EAL-B11-03 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.9.66 EAL-B11-04 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.5.9.67 EAL-B12-02 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 138/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
0 0 0 0 0
15.60 LPG SYSTEM 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.6.1 Pipework 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply, install test & commission, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions" Schedule 40 - inside buildings 0 0 0 0 0

only for diwanyah and Guest villa 0 0 0 0 0


15.6.1.1 25 mm diameter pipe LM 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.6.1.2 32 mm diameter pipe LM 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.6.1.3 40 mm diameter pipe LM 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply, install & test PVC coated Copper pipes for gas
system, complete with fittings & all related works
(valves at termination points to be included in the 0 0 0 0 0
rate).APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"
15.6.1.4 20 mm diameter pipe LM 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.6.2 Gas Valves 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply Isolating ball valves, quarter-turn, installed,
connected, and tested complete including all 0 0 0 0 0
accessories, all as specified and shown on drawings.
15.6.2.1 20 mm diameter No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.6.3 Solenoid Gas Valves 0 0 0 0 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 139/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply Solenoid gas valves, installed, connected, and
tested, complete including all accessories as specified 0 0 0 0 0
and shown on drawings.
0 0 0 0 0
15.6.3.1 40 mm diameter No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.6.4 Gas Regulators 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Gas regulators, installed, connected, and tested
complete with isolating valve, including all accessories 0 0 0 0 0
as specified and shown on drawings.
0 0 0 0 0
15.6.4.1 32 mm diameter No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.6.6 Gas Manifold 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply Gas manifold, installed, tested, complete with
steel cabinets, branch gas valves and accessories, all
as specified and shown on drawings. 0 0 0 0 0

0 0 0 0 0
15.6.6.1 Gas Manifold No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0

SWIMMING POOL SYSTEM AND FOUNTAINS 0 0 0 0 0 0 0 0 0


15.70
0 0 0 0 0
15.7.1 PVC Pipes 0 0 0 0 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 140/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0 0 0 0 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0 0 0 0 0
15.7.1.5 63 mm LM 0 0 0 0 0 140 0 0 0
0 0 0 0 0
15.7.1.6 75 mm LM 0 0 0 0 0 60 0 0 0
0 0 0 0 0
15.7.1.7 110 mm LM 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.7.1.8 160mm LM 0 0 0 0 0 55 0 0 0
0 0 0 0 0
15.7.2 Swimming pool pump 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0 0 0 0 0

15.7.2.4 FP-B07-1 No. 0 0 0 0 0 4 0 0 0


0 0 0 0 0
15.7.2.5 FP-B11-1 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.7.2.6 FP-B12-1 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.7.3 Inlet Fitting 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0 0 0 0 0
specified and shown on drawings

0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 141/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0 0 0 0 0 6 0 0 0


15.7.4 Vacuum Fitting 0 0 0 0 0 0 0 0 0
0 0 0 0 0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0 0 0 0 0
drawings

0 0 0 0 0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0 0 0 0 0 2 0 0 0
0 0 0 0 0
15.7.5 Main Drain 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0 0 0 0 0
shown on drawings
0 0 0 0 0
15.7.5.1 Main drain MD No. 0 0 0 0 0 6 0 0 0
0 0 0 0 0
15.7.6 Overflow Trench Fitting 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0 0 0 0 0
spesified and shown on drawings.

0 0 0 0 0
15.7.6.1 Overflow Trench LM 0 0 0 0 0 40 0 0 0
0 0 0 0 0
15.7.7 Outlet Fitting 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
0 0 0 0 0
specified and shown on drawings

0 0 0 0 0
15.7.7.1 Outlet fitting 75mm diameter No. 0 0 0 0 0 4 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 142/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
15.7.8 Fill Fitting 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0 0 0 0 0

0 0 0 0 0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0 0 0 0 0 2 0 0 0
0 0 0 0 0
15.7.9 Pool Sand Filter 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0 0 0 0 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

15.7.9.1 SF-B07-1 No. 0 0 0 0 0 2 0 0 0


0 0 0 0 0
15.7.9.2 SF-B11-1 Set. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.7.9.3 SF-B12-1 Set. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.7.10 Chemical Feeding and Control Accessories 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0 0 0 0 0

0 0 0 0 0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0 0 0 0 0 2 0 0 0
0 0 0 0 0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0 0 0 0 0

0 0 0 0 0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0 0 0 0 0 2 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 143/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

15.7.10.3 Chemical test kit No. 0 0 0 0 0 2 0 0 0


0 0 0 0 0
15.7.11 Balance Tank 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0 0 0 0 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0 0 0 0 0
Capacity (4) m3 0 0 0 0 0
15.7.11.1.1 BT-B07-1 No. 0 0 0 0 0 2 0 0 0
15.7.11.1.2 BT-B11-1 No. 0 0 0 0 0 0 0 0 0
15.7.11.1.3 BT-B12-1 No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
15.7.12 Electrical Heat Exchanger 0 0 0 0 0 0 0 0 0
0 0 0 0 0
Supply Stainless steel pool heat exchanger, installed 0 0 0 0 0
and tested complete with Digital Thermostat, valves, 0 0 0 0 0
control valve & all related works as specified and 0 0 0 0 0
shown on drawings. 0 0 0 0 0
0 0 0 0 0
Pool Heat Exchanger H.X 0 0 0 0 0
15.7.12.1 P- HE-01 (21 KW) No. 0 0 0 0 0 2 0 0 0
0 0 0 0 0
15.7.12.2 P- HE-02 (30 KW) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
DIV#15 Total cost of this section Carried Forward To Summary - - - - -

16.10 DIV#16 ELECTRICAL WORKS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 144/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.1.1 Ref. SMDB-DW No. 0 0 0 0 0 0 0 0 0


16.1.2 Ref. SMDB-G.V No. 0 0 0 0 0 0 0 0 0
16.1.3 Ref. ESMDB-G.V No. 0 0 0 0 0 0 0 0 0
16.1.4 Ref. SMDB-M.V No. 0 0 0 0 0 0 0 0 0
16.1.5 Ref. SMDB-A.V No. 0 0 0 0 0 0 0 0 0
16.1.6 Ref. SMDB-D.A/X (X: R/1, L/1, R/2, L/2) No. 0 4 0 0 0 0 0 0 0
16.1.7 Ref. SMDB-C.H No. 0 0 0 1 0 0 0 0 0
16.1.8 Ref. ESMDB-C.H No. 0 0 0 1 0 0 0 0 0
16.1.9 Ref. SMDB-MA No. 0 0 0 0 0 1 0 0 0
16.1.10 Ref. ESMDB-MA No. 0 0 0 0 0 1 0 0 0
16.1.11 Ref. SMDB-NA No. 0 0 0 0 0 1 0 0 0
16.1.12 Ref. SMDB-DM&N No. 0 0 0 0 0 0 0 1 0
16.1.13 Ref. SMDB-A'A.V No. 0 0 0 0 0 0 0 0 0
16.1.14 Ref. SMDB-M.V/X (X: R, L) No. 0 0 0 0 0 0 0 0 0
16.1.15 Ref. SMDB-DI&A No. 0 0 0 0 0 0 0 0 0
16.1.16 Ref. SMDB-I No. 0 0 0 0 0 0 0 0 0
16.1.17 Ref. SMDB-AE No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
16.20 Motor Control Center 0 0 0 0 0 0 0 0 0
Section 16443 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 145/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0 0 0 0 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
16.2.1 Ref. MCC-R No. 0 0 0 1 0 0 0 1 0
16.2.1.1 Ref. MCC-R/I No. 0 0 0 0 0 0 0 0 0
16.2.2 Ref. EMCC-R No. 0 0 0 1 0 0 0 0 0
16.2.3 Ref. MCC-R/X (X: R/1, L/1, R/2, L/2) No. 0 4 0 0 0 0 0 0 0
16.2.4 Ref. MCC-R1/M No. 0 0 0 0 0 1 0 0 0
16.2.5 Ref. MCC-R2/M No. 0 0 0 0 0 1 0 0 0
16.2.6 Ref. MCC-P/M No. 0 0 0 0 0 1 0 0 0
16.2.7 Ref. MCC-R1/N No. 0 0 0 0 0 1 0 0 0
16.2.8 Ref. MCC-R2/N No. 0 0 0 0 0 1 0 0 0
16.2.9 Ref. MCC-P/N No. 0 0 0 0 0 1 0 0 0
16.2.10 Ref. MCC-R/X (X: R, L) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
16.30 Distribution Boards 0 0 0 0 0 0 0 0 0
16.3.1 Ref. DB-B No. 0 0 0 1 0 0 0 0 0
16.3.2 Ref. DB-G No. 0 0 0 0 0 0 0 0 0
16.3.3 Ref. DB-F No. 0 0 0 0 0 0 0 0 0
16.3.3.1 Ref. DB-F/AE 0 0 0 0 0 0 0 0 0
16.3.4 Ref. DB-R No. 0 0 0 0 0 0 0 0 0
16.3.4.1 Ref. DB-R/AE 0 0 0 0 0 0 0 0 0
16.3.5 Ref. EDB-G/I No. 0 0 0 0 0 0 0 0 0
16.3.5.1 Ref. EDB-G/AE 0 0 0 0 0 0 0 0 0
16.3.6 Ref. EDB-F No. 0 0 0 0 0 0 0 0 0
16.3.8 Ref. DP-B/I No. 0 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 146/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
16.3.8.1 Ref. DP-B/AE No. 0 0 0 0 0 0 0 0 0
16.3.9 Ref. DL-B No. 0 0 0 0 0 0 0 0 0
16.3.10 Ref. EDB-B No. 0 0 0 1 0 0 0 0 0
16.3.10.1 Ref. DB-G-DI&A 0 0 0 0 0 0 0 0 0
16.3.11 Ref. EDB-K No. 0 0 0 0 0 0 0 0 0
16.3.12 Ref. DP-G No. 0 0 0 0 0 0 0 0 0
16.3.13 Ref. DL-G No. 0 0 0 0 0 0 0 0 0
16.3.14 Ref. EDB-G No. 0 0 0 0 0 0 0 0 0
16.3.15 Ref. DP-F No. 0 0 0 0 0 0 0 0 0
16.3.16 Ref. DL-F No. 0 0 0 0 0 0 0 0 0
16.3.17 Ref. DB-B/X (X: R/1, L/1, R/2, L/2) No. 0 4 0 0 0 0 0 0 0
16.3.18 Ref. DB-G/X (X: R/1, L/1, R/2, L/2) No. 0 4 0 0 0 0 0 0 0
16.3.19 Ref. DB-F/X (X: R/1, L/1, R/2, L/2) No. 0 4 0 0 0 0 0 0 0
16.3.23 Ref. DB-R/X (X: R/1, L/1, R/2, L/2) No. 0 4 0 0 0 0 0 0 0
16.3.24 Ref. DB-GR No. 0 0 0 1 0 0 0 0 0
16.3.25 Ref. DB-GL No. 0 0 0 1 0 0 0 0 0
16.3.26 Ref. DB-EX No. 0 0 0 1 0 1 0 0 0
16.3.27 Ref. DB-SM No. 0 0 0 0 0 1 0 0 0
16.3.28 Ref. EDB-S No. 0 0 0 0 0 1 0 0 0
16.3.29 Ref. DB-GM No. 0 0 0 0 0 1 0 0 0
16.3.30 Ref. EDB-GM No. 0 0 0 0 0 1 0 0 0
16.3.31 Ref. DB-FM No. 0 0 0 0 0 1 0 0 0
16.3.32 Ref. DB-RM No. 0 0 0 0 0 1 0 0 0
16.3.33 Ref. DB-KM No. 0 0 0 0 0 1 0 0 0
16.3.34 Ref. EDB-KM No. 0 0 0 0 0 1 0 0 0
16.3.35 Ref. DB-SP No. 0 0 0 0 0 1 0 0 0
16.3.36 Ref. DB-SL No. 0 0 0 0 0 1 0 0 0
16.3.37 Ref. DB-KN No. 0 0 0 0 0 1 0 0 0
16.3.38 Ref. EDB-KN No. 0 0 0 0 0 1 0 0 0
16.3.39 Ref. DB-GN No. 0 0 0 0 0 1 0 0 0
16.3.40 Ref. DB-FN No. 0 0 0 0 0 1 0 0 0
16.3.41 Ref. DB-RN No. 0 0 0 0 0 1 0 0 0
16.3.42 Ref. EDB-GN No. 0 0 0 0 0 1 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 147/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
16.3.43 Ref. DB-B/S No. 0 0 0 0 0 1 0 0 0
16.3.44 Ref. EDB-S No. 0 0 0 0 0 0 0 0 0
16.3.45 Ref.DB-DM&N No. 0 0 0 0 0 0 0 1 0
16.3.46 Ref.EDB-DM&N No. 0 0 0 0 0 0 0 1 0
16.3.47 Ref. DB-B/X (X: R, L) No. 0 0 0 0 0 0 0 0 0
16.3.48 Ref. DB-G/X (X: R, L) No. 0 0 0 0 0 0 0 0 0
16.3.49 Ref. DB-F/X (X: R, L) No. 0 0 0 0 0 0 0 0 0
16.3.50 Ref. EDB-B/X (X: R, L) No. 0 0 0 0 0 0 0 0 0
16.3.51 Ref. DB-K/X (X: R, L) No. 0 0 0 0 0 0 0 0 0
16.3.52 Ref. DB-R/X (X: R, L) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0
16.40 Feeders 0 0 0 0 0 0 0 0 0
Section 16122 0 0 0 0 0

Feeders, conductors and cables including all necessary


supports, brackets, pipes, cable trayes (where needed) ,
conduits, manholes (if needed), luges, glands, cable 0 0 0 0 0
terminaL.S , terminations and electrical connections and
all needed accessories as shown on the drawings.

0 0 0 0 0
16.4.1 2(4x240) mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 150 0 0 0
16.4.4 4x300mm² CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0 0 0
16.4.5 4x240 mm2 CU/XLPE/SWA/PVC LM 0 0 0 65 0 0 0 0 0
16.4.6 4x185 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0 0 0
16.4.7 4x150 mm2 CU/XLPE/SWA/PVC LM 0 650 0 0 0 0 0 0 0
16.4.8 4x120 mm2 CU/XLPE/SWA/PVC LM 0 0 0 130 0 0 0 100 0
16.4.9 4x70 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0 0 0
16.4.10 4x240mm² CU/XLPE/PVC + 1x120mm² Y/G PVC CABLE LM 0 0 0 0 0 35 0 0 0
16.4.11 4x150mm² CU/XLPE/PVC + 1x70mm² Y/G PVC CABLE LM 0 0 0 0 0 30 0 0 0
16.4.12 4x120mm² CU/XLPE/PVC + 1x70mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0 0 0
16.4.13 4x95mm² CU/XLPE/PVC + 1x50mm² Y/G PVC CABLE LM 0 0 0 35 0 0 0 10 0
16.4.14 4x70mm² CU/XLPE/PVC + 1x35mm² Y/G PVC CABLE LM 0 140 0 35 0 30 0 0 0
16.4.15 4x50mm² CU/XLPE/PVC + 1x25mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0 0 0

16.4.16 4x25mm² CU/XLPE/SWA/PVC + 1x16mm² Y/G PVC CABLE LM 0 0 0 0 0 20 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 148/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
16.4.17 4x35mm² CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0 0 0

16.4.19 4x10mm² CU/XLPE/SWA/PVC + 1x10mm² Y/G PVC CABLE LM 0 940 0 0 0 0 0 0 0

16.4.20 4x16mm2 CU/XLPE/PVC/PVC +1X16mm² Y/G PVC LM 0 0 0 0 0 80 0 10 0


16.4.21 4x10mm² CU/PVC/PVC+1x10mm² Y/G PVC CABLE LM 0 100 0 35 0 180 0 10 0
16.4.22 5x6mm² CU/PVC/PVC CABLE LM 0 100 0 10 0 20 0 0 0
16.4.23 3x6mm² CU/PVC/PVC CABLE LM 0 0 0 10 0 20 0 0 0
0 0 0 0 0
16.50 Isolating switches 0 0 0 0 0 0 0 0 0
0 0 0 0 0

Supply, install, test and commission Isolating switch


points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0 0 0 0 0
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

0 0 0 0 0
16.5.1 25A, SPN ,IP65 No. 0 28 0 3 0 40 0 4 0
16.5.2 25A, TPN ,IP65 No. 0 16 0 11 0 8 0 6 0
16.5.3 32A, SPN ,IP65 No. 0 0 0 0 0 3 0 2 0
16.5.4 32A, TPN ,IP65 No. 0 32 0 4 0 26 0 1 0
16.5.5 32A, SPN ,IP54 for D.W No. 0 0 0 1 0 2 0 0 0
16.5.6 40A, TPN ,IP65 No. 0 0 0 0 0 2 0 0 0
16.5.7 50A, TPN ,IP65 No. 0 0 0 2 0 0 0 0 0
16.5.8 63A, TPN ,IP66 No. 0 0 0 0 0 0 0 2 0
16.5.9 80A, TPN ,IP65 No. 0 0 0 2 0 1 0 0 0
16.5.10 100A, TPN ,IP65 No. 0 0 0 2 0 1 0 0 0
0 0 0 0 0
16.60 Power Socket Outlets 0 0 0 0 0 0 0 0 0
Sections 16020, 16120, 16130 ,16140 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 149/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, test and commission Socket outlet


pints only including all necessary PVC conduits,
wires, cables, pull and junctions boxes , floor boxes
(where needed as per drawings) ,cover plates , 0 0 0 0 0
ancillaries , connections, and all needed accessories
as shown on the drawings . excluding outlet device
and face plate .

0 0 0 0 0
Socket outlet, 13A, 1- phase, 1- gang , switched (wall or 0 172 0 45 0 169 0 21 0
16.6.1 No.
in floor mounted box)

16.6.2 Ditto but ceiling mounted No. 0 104 0 5 0 85 0 7 0

16.6.3 Ditto but water proof No. 0 74 0 10 0 70 0 8 0

16.6.4 Ditto but double gang(wall or in floor mounted box) No. 0 48 0 8 0 47 0 8 0

16.6.5 Ditto but double gang water proof No. 0 0 0 0 0 0 0 6 0

16.6.6 Power points for motorized shutter No. 0 68 0 26 0 55 0 15 0

16.6.7 Spur outlet for electrical water heater No. 0 64 0 8 0 0 0 3 0

16.6.9 Power points for hand & hair ddryer No. 0 12 0 8 0 25 0 5 0

16.6.13 Power points for Jaccuzi OR Fountains No. 0 0 0 0 0 0 0 0 0

20A, double pole switch with neon.


16.6.8 No. 0 32 0 0 0 0 0 3 0

Socket outlet, 15A, 1- phase, 1- gang , for washer or 0 20 0 0 0 12 0 0 0


16.6.10 No.
dryer

16.6.11 Ditto but 3-phase No. 0 0 0 0 0 0 0 0 0

16.6.11.1 FLOOR BOX 2P+1D No. 0 0 0 0 0 0 0 0 0

16.6.11.2 FLOOR BOX 1P+1TV No. 0 4 0 0 0 0 0 0 0

16.6.11.3 FLOOR BOX 2P+1D+1TV No. 0 8 0 0 0 3 0 0 0

0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 150/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
WIRING DEVICES : 0 0 0 0 0

INSTALL ONLY ( SUPPLY BY OTHERS) WIRING 0 0 0 0 0


DEVICES INCLUDES ALL ACCESSORIES , (GFCI)

0 0 0 0 0
Single Switched socket 13A,220v (2P+E) Grounding type 0 172 0 42 0 136 0 21 0
16.6.14 NO

16.6.15 Double socket 13A,220v (2P+E),Grounding type NO 0 32 0 3 0 47 0 14 0

Single socket 13A,220v (2P+E) GFCI,with earth leakage 0 0 0 0 0 0 0 0 0


16.6.16 NO
protection

celing power socket 13A ,220v for AC (2P+E) 0 172 0 15 0 140 0 15 0


16.6.17 NO
Grounding type

16.6.18 Single socket 20A,220v (2P+E) FOR WATER HEATER NO 0 32 0 8 0 0 0 3 0

16.6.19 2phase socket 20A,220v (3P+E) with neon type, NO 0 32 0 0 0 0 0 3 0

SUPPLY AND INSTALL WIRING DEVICES


INCLUDES ALL ACCESSORIES (GFCI) 0 0 0 0 0
for maid , laundary, storage rooms

SUPPLY AND INSTALL Single Switched socket 13A,220v 0 0 0 3 0 33 0 0 0


16.6.21 NO
(2P+E) Grounding type (legrand/MK) or eqivelant

16.6.22 Double socket 13A,220v (2P+E),Grounding type NO 0 16 0 5 0 0 0 0 0

wall power socket 32 A ,220v for AC (2P+E) Grounding


16.6.23 type WATHER PROOF NO 0 0 0 0 0 15 0 0 0

0 0 0 0 0
16.70 Lighting System 0 0 0 0 0 0 0 0 0
Sections 16010, 16120 ,16510 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 151/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, test and commission Lighting points


with all necessary conduits, conductors , cables &
wires , junction , pull boxes, connections, 0 0 0 0 0
accessories, fittings, and all needed accessories as
shown on the drawings.

0 0 0 0 0
16.7.1 Internal Lighting points with wire size 2.5 mm2 No. 0 856 0 282 0 985 0 107 0

16.7.2 External Lighting points with wire size 6 or 10 mm2 No. 0 20 0 125 0 85 0 4 0

0 0 0 0 0
16.80 Lighting Fixtures 0 0 0 0 0 0 0 0 0
Sections 16010, 16120 ,16510 0 0 0 0 0

install only test and commission Lighting fixtures


and switches with all necessary accessories and 0 0 0 0 0
termination as shown on the drawings.

0 0 0 0 0
16.8.1 Type F1 No. 0 48 0 2 0 50 0 8 0
16.8.2 Type F2 No. 0 136 0 0 0 0 0 0 0
16.8.3 Type F3 No. 0 240 0 23 0 456 0 99 0
16.8.4 Type F4 No. 0 52 0 30 0 62 0 11 0
16.8.5 Type F5 No. 0 0 0 12 0 15 0 0 0
16.8.6 Type F6 No. 0 44 0 0 0 27 0 0 0
16.8.7 Type F7 No. 0 76 0 0 0 77 0 9 0
16.8.8 Type F8 No. 0 84 0 44 0 91 0 0 0
16.8.9 Type F9 No. 0 20 0 8 0 13 0 2 0
16.8.10 Type F11 No. 0 32 0 20 0 42 0 3 0
16.8.11 Type F12 No. 0 12 0 0 0 0 0 0 0
16.8.13 Type F14 No. 0 0 0 0 0 18 0 0 0
16.8.14 Type F14E No. 0 0 0 0 0 3 0 0 0
16.8.15 Type F15 No. 0 0 0 18 0 1 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 152/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
16.8.16 Type F15E No. 0 0 0 0 0 2 0 1 0
16.8.17 Type F18 No. 0 0 0 15 0 0 0 2 0
16.8.18 Type F19 No. 0 24 0 24 0 49 0 1 0
16.8.20 Type EX1 No. 0 0 0 42 0 4 0 0 0
16.8.21 Type EX3 No. 0 0 0 8 0 24 0 16 0
16.8.22 Type EX4 No. 0 20 0 16 0 45 0 18 0
16.8.23 Type EX5 No. 0 0 0 34 0 5 0 0 0
16.8.24 Type EX6 No. 0 0 0 26 0 0 0 0 0
supply and install,test and commission Lighting
fixtures and lighting switches (All fixtures shall be
supplied in full coordination with client or client's
representative) including all necessary transformer
ballast, switch gear, lamps, lamp holders, diffusers,
internal wires, supports, clamps, conduits,
connections, terminations, fixings, fittings and all 0 0 0 0 0
needed accessories and as shown on the drawings.
for maid, laundary, storage rooms

0 0 0 0 0
16.8.25 Type F1 No. 0 0 0 0 0 8 0 0 0
16.8.26 Type F4 No. 0 0 0 0 0 13 0 0 0
16.8.27 Type F9 No. 0 0 0 0 0 8 0 0 0
16.8.29 Type F14 No. 0 12 0 0 0 0 0 0 0
16.8.30 Type F15 No. 0 12 0 5 0 28 0 0 0
16.8.31 Type F15E No. 0 12 0 1 0 7 0 0 0
16.8.32 Type F19 No. 0 0 0 0 0 6 0 0 0
0 0 0 0 0
16.90 Fire Alarm Installation 0 0 0 0 0 0 0 0 0
Sections 16710 Fire Alarm 0 0 0 0 0
0 0 0 0 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reSet button, switches,
batteries, charger, internal conductor, enclosure and all
16.9.1 0 0 0 0 0 0 0 0 0
other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 153/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0 0
16.9.1.1 Fire alarm Slave panel, ref. SACP-DW (1 loop) No. 0 0 0 0 0 0 0 0 0
16.9.1.2 Fire alarm Slave panel, ref. SACP-G.V (1 loop) No. 0 0 0 0 0 0 0 0 0
16.9.1.3 Fire alarm Slave panel, ref. SACP-M.V (1 loop) No. 0 0 0 0 0 0 0 0 0
16.9.1.4 Fire alarm Slave panel, ref. SACP-A.V (1 loop) No. 0 0 0 0 0 0 0 0 0
16.9.1.5 Fire alarm Slave panel, ref. SACP-D.A/X (1 loop) No. 0 4 0 0 0 0 0 0 0
16.9.1.6 Fire alarm Slave panel, ref. SACP-C.H (1 loop) No. 0 0 0 1 0 0 0 0 0
16.9.1.7 Fire alarm Slave panel, ref. SACP-M&N (3 loops) No. 0 0 0 0 0 1 0 0 0
16.9.1.8 Fire alarm Slave panel, ref. SACP-DM&N (1 loop) No. 0 0 0 0 0 0 0 1 0
16.9.1.9 Fire alarm Slave panel, ref. SACP-A.V (1 loop) No. 0 0 0 0 0 0 0 0 0

16.9.1.10 Fire alarm Slave panel, ref. SACP-M.V/X (X: R, L) (1 loop) No. 0 0 0 0 0 0 0 0 0

16.9.1.11 Fire alarm Slave panel, ref. SACP-DI&A (1 loop) No. 0 0 0 0 0 0 0 0 0


16.9.1.12 Fire alarm Slave panel, ref. SACP-I.V (1 loop) No. 0 0 0 0 0 0 0 0 0
16.9.1.13 Fire alarm Slave panel, ref. SACP-AE.V (1 loop) No. 0 0 0 0 0 0 0 0 0
0 0 0 0 0

Addressable Fire alarm devices including covers,


fixings ,conductors, conduits, pull and junction boxes, 0 0 0 0 0 0 0 0 0
16.9.2
cables, wires, connections and terminations, and all
needed accessories as shown on the drawings.

0 0 0 0 0
16.9.2.1 Addressable smoke detector No. 0 12 0 4 0 22 0 1 0
16.9.2.2 Ditto but with sound base No. 0 62 0 24 0 95 0 7 0
16.9.2.3 Addressable heat detector No. 0 12 0 2 0 12 0 1 0
16.9.2.4 Ditto but with sound base No. 0 0 0 0 0 0 0 4 0
16.9.2.5 Break glass station No. 0 36 0 18 0 10 0 1 0
16.9.2.6 Audible/visual warning devices indoor No. 0 4 0 4 0 4 0 1 0
16.9.2.7 Audible/visual warning devices outdoor No. 0 4 0 4 0 4 0 1 0
0 0 0 0 0
16.10 EARTHING SYSTEM 0 0 0 0 0 0 0 0 0
Sections 16125 EARTHING 0 0 0 0 0
0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 154/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,8 earthing pits, various
corner earthing points of the building , connected with
16.10.1 ls 0 2 0 1 0 1 0 1 0
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0 0 0 1 0 0
16.10.2 ls
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0 0 0 0 0
16.11 CCTV SYSTEM 0 0 0 0 0 0 0 0 0
0 0 0 0 0

Sections 16690 IP network components,16690 , 0 0 0 0 0


16738,16739

supply and Install only indoor cameras's points including


all necessary empty PVC conduits from data cabinet to 0 12 0 0 0 10 0 2 0
16.11.4 point's location , pull junction boxes, and all needed
accessories as per drawings.

0 0 0 0 0
16.12 LOW CURRENT SYSTEMS 0 0 0 0 0 0 0 0 0

Sections 16110, 16120, 16130, 16140, 16690 0 0 0 0 0


IP network

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 155/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount
components,16700 ,16738,16739 0 0 0 0 0

Voice & Data Distribution System

Supply and install of voice & data distribution Equipment,


including but not limited to connections, supports , patch
panel , distributer switches , ends of cables ,data rack 9u
cabenit and all necessary accessories; all in accordance
with the Drawings and Specifications and as approved by
16.12.1.1 owner .  set 0 0 0 0 0
A) the main
distributor (SWITCH to connect devices not less than
1000 MB .
B) Distributor SWITCH devices to
wall outlet not less than 100 MB (By Others )

0 0 0 0 0

Supply, install, test and commission voice & data


distribution circuit points , including all ,
fixings ,wires, cat6 A ,cable terminals, cable trunks
and trays ,conduits, pull and junction boxes, floor 0 0 0 0 0
suuports (where needed as per drawings) ,cover
plates , connections from data rack to the outlet, and
all needed accessories as shown on the drawings.
excluding outlet device and face plate .

0 0 0 0 0

16.12.1 RJ45 socket outlet wall No. 0 68 0 8 0 49 0 5 0

16.12.2 Access point installed above false ceiling No. 0 16 0 9 0 11 0 2 0

16.12.3 RJ45 Data socket outlet , installed in floor mounted box No. 0 8 0 0 0 0 0 0 0

16.12.4 RJ45 access point installed above faL.Se ceiling No. 0 16 0 9 0 11 0 0 0

RJ45 socket outlet used for IP- camera (only for 0 12 0 2 0 12 0 1 0


16.12.5 No.
outdoor type and for indoor at main diwaniah & gust villa)

0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 156/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply and installation of reception satellite system


including reception and rules dishes , receivers,
amplifiers , LNP, links, boxes and dividers with 0 4 0 1 0 2 0 1 0
16.12.5.1 LS
adjustment, calibration, operation and delivery ,
programming of required stations and all in
accordance with the details shown on drawings

0 0 0 0 0

supply and install installation and test Mural TV socket


outlet includes boxes, coaxial cables , pipes , conduits 0 28 0 1 0 24 0 3 0
16.12.5.2 No.
and all needed accessories , excluding outlet device and
face plate .

0 0 0 0 0

Supply, install, test and commission Inter come system


includs indoor unit , out door unit , 2P cables and 0 4 0 1 0 2 0 0 0
16.14 LS
connections , PVC conduits , power supply , and all
needed accessories and as shown on the drawings .

0 0 0 0 0

Elevators & Dumbwaiter electrical work related 0 0 0 0 0 0 0 0 0


16.16 only )

0 0 0 0 0

install, test and commission an electrical feeding points


16.16.1 for electrical elevators , with all necessary equipment No. 0 0 0 0 0 2 0 0 0
(for specification refer to CONVEYING SYSTEM div 14.1)

0 0 0 0 0

16.16.2 Ditto but for dumbwaiter No. 0 0 0 1 0 2 0 0 0

0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 157/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, test and commission (6W) Ceiling metallic


16.17 loudspeaker (Recessed) complete with wires , and all No. 0 0 0 25 0 0 0 0 0
needed accessories as shown on the drawings.

0 0 0 0 0

Supply, install, test and commission (10W) Ceiling


16.18 metallic loudspeaker wall mounted complete with wires , No. 0 0 0 12 0 0 0 0 0
and all needed accessories as shown on the drawings

0 0 0 0 0
16.19 Ditto but weather proof No. 0 0 0 6 0 0 0 0 0
0 0 0 0 0

Supply, install, test and commission Music Rack located


at control room at roof complete with wires, conduits ,
Amplifiers , power supply , back up batteries, AM/FM
digital tuner , DVD player, MP3 player , CD player , 0 0 0 1 0 0 0 0 0
16.20. LS
CasSette player , Portable UHF- Band Wireless
microphone (complet with receiver and transmitter) ,
microphone , and all needed accessories as shown on the
drawings

0 0 0 0 0
0 0 0 0 0

DIV#16 Total cost of this section Carried Forward To Summary 0 0 0 0 0

*** NOTE:- 0 0

Item overlooked in the bill of quantity but shown


in drawings, specification and schedules
necessary for the satisfactory completion of the
works may be priced hereunder.

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary - - - - -

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 158/2284


DIVISION # 1~16 / ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

1xDUPLEX VILLA MAJID & NASER MAJID & NASER


ABDULL AZIZ CLUB HOUSE
(2xTYP. ) VILLA DIWANIAH

ITEM DIV B04 B05 A&B B06 B07 B08


DESCRIPTION UNIT
# # Amount Qty. Amount Qty. Amount Qty. Amount Qty. Amount

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 159/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

1.10 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.10 see seprate BOQ for Div # 1 ( general requirments for BOQ LS 0 0 0 0

DIV#1 Total cost of this section Carried Forward To Summary - - - -

2.00 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

2.30 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 2603 0 3027 0 6143 0 699 0
0 0 0 0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0 0 0 0
each, complete

0 0 0 0
2.3.2 Up to levels and around & above foundations. m3 600 0 803 0 1653 0 467 0
0 0 0 0
Crushed aggregate base course, compacted to 100%
0 0 0 0
modified AASHTO density CBR ≥ 80%
0 0 0 0
2.3.3 250mm thick under slabs on grade m2 438 0 480 0 982 0 420 0
0 0 0 0
2.40 ANTI TERMITE 0 0 0 0
Refer to spesification # 2285 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 160/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
2.4.1 Termite control treatment for all vertical and L.S 1 0 1 0 1 0 1 0
horizontal areas complete in accordance with 0 0 0 0
specifications.

DIV#2 Total cost of this section Carried Forward To Summary - - - -

3.00 DIV#3 CONCRETE WORKS

Plain concrete (grade 15), 15N/mm2 at 28 days cylinder


compressive strength, using portland cement, including all
3.10 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 39 0 34 0 54 0 14 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 20 0 22 0 45 0 20 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 2 0 2 0 5 0 3 0


0 0 0 0
Cyclopean concrete; comprising of 50:50 plain concrete 0 0 0 0
and stone
0 0 0 0
3.1.5 Pedestals under tie beams; size 500x500x500mm m3 4 0 4 0 2 0 2 0
0 0 0 0
Reinforced cast in situ concrete (grade 30), 30N/mm2
,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.20 including high tensile steel reinforcement grade 420Mpa 0 0 0 0 0 0 0 0
and mild steel reinforcement grade 280Mpa (Φ8mm); to

0 0 0 0

3.2.1 Foundations; (single, compound ) m3 110 0 66 0 145 0 43 0


0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 161/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

3.2.1.1 Foundations; (Raft , continous ) 78 0 67 0 91 0 5 0

0 0 0 0
3.2.2 Tie beams - Intermediate m3 0 0 0 0 69 0 26 0
0 0 0 0
3.2.3 Upper tie beams m3 32 0 26 0 69 0 26 0
0 0 0 0
3.2.4 Slabs on grade m3 76 0 82 0 160 0 51 0
0 0 0 0
3.2.5 Walls below slab on grade m3 33 0 81 0 125 0 11 0
0 0 0 0
3.2.6 Columns Below slab on grade m3 8 0 9 0 40 0 21 0
0 0 0 0
3.2.7 Water Tanks Slabs and Walls m3 92 0 71 0 160 0 118 0
0 0 0 0
3.2.8 Swimming pool Slabs and Walls m3 0 0 0 0 109 0 85 0
0 0 0 0
3.2.9 Car Park Roof Slab m3 0 0 0 0
0 0 0 0
0 0 0 0
Reinforced cast in situ concrete (grade 30), 30N/mm2
,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.30 and mild steel reinforcement grade 280Mpa (Φ8mm); to 0 0 0 0 0 0 0 0

0 0 0 0
3.3.1 Columns above slab on grade m3 45 0 157 0 212 0 45 0
0 0 0 0
3.3.2 Shear Walls , free standing walls above slab on Grade m3 61 0 102 0 133 0 12 0
0 0 0 0
3.3.3 Suspended solid slabs; including drop beams m3 386 0 332 0 789 0 0 0
0 0 0 0
Ribbed slabs;including hollow concrete blocks and hidden
3.3.4 beams -Ribs m2 0 0 0 0 0 0 342 0

0 0 0 0
3.3.5 Stairs (steps, flights and landing) m3 17 0 35 0 42 0 0 0
0 0 0 0
3.3.6 Beams m3 31 0 33 0 45 0 5 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 162/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
3.40 CONCRETE PROTECTION AND INSULATION 0 0 0 0 0 0 0 0

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers; 0 0 0 0
1.5 liters/m2
Supply, install and test of the liquid applied polyurethane
waterproofing; applied in two layers; 1.5 liters/m 2 0 0 0 0

0 0 0 0
3.4.1 To all structural elements below grade m2 959 0 674 0 1794 0 732 0
0 0 0 0
4mm thick torch applied SBS modified bituminous
polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and 0 0 0 0
specifications

0 0 0 0
3.4.2 To basement's walls - Vertical m2 243 0 430 0 650 0 0 0
3.4.2.1 Below slab on grade for basements -Horizontal 377 0 410 0 798 0 258 0
3.4.2.2 Water Tanks 345 0 315 0 452 0 294 0
3.4.2.3 Swimming pools 0 0 0 0 386 0 227 0
0 0 0 0
PVC water stop, web thickness (4-5) mm, complete as
detailed on drawings and as specified 0 0 0 0

0 0 0 0
3.4.5 To water tanks; 250mm wide mr 27 0 27 0 56 0 50 0
0 0 0 0

DIV#3 Total cost of this section Carried Forward To Summary - - - -

4.00 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and


internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 163/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.10 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2 882 0 903 0 1540 0 307 0
and one layer of 150 mm concrete masoNo.y units 0 0 0 0
for external wall including reinforcement and 50 0 0 0 0
mm polyurethane foam insulation as specified in 0 0 0 0
the drawings & specifications:- 0 0 0 0
0 0 0 0
4.20 CMU walls Without Isolation 0 0 0 0
0 0 0 0
4.2.1 350 mm thick (CMU) block masoNo.y works to m2 0 0 18 0 0 0 0
internal / partition walls 0 0 0 0
0 0 0 0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 63 0 433 0 5 0 0 0
internal / partition walls / Parapet 0 0 0 0
0 0 0 0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 34 0 0 0 0 0 0 0
internal / partition walls / Parapet 0 0 0 0
0 0 0 0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 745 0 97 0 929 0 97 0
internal / partition walls / Parapet 0 0 0 0
0 0 0 0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 131 0 576 0 486 0 149 0
internal / partition walLS 0 0 0 0
0 0 0 0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 232 0 475 0 1320 0 90 0
internal /partition walLS 0 0 0 0
0 0 0 0
4.30 Forming of Arch. Shape 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 164/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
4.3.1 Construction of block masonry works, to get m3 0 0 0 0
shape as per architectural design . 0 0 0 0
0 0 0 0
DIV#4 Total cost of this section Carried Forward To Summary - - - -

5.10 DIV#5 METAL WORKS LS 0 0 0 0


NA

DIV#5 Total cost of this section Carried Forward To Summary - - - -

6.10 DIV#6 WOOD & PLASTIC LS 0 0 0 0


NA

DIV#6 Total cost of this section Carried Forward To Summary - - - -

7.10 DIV#7 THERMAL & MOISTURE

7.10 Waterproofing

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 165/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 376 0 419 0 826 0 292 0
moisture protection and waterproofing consisting 0 0 0 0
of 40 mm smooth finish sloping screed over roof 0 0 0 0
slab, 3+3 modified bituminous waterproofing 0 0 0 0
membrane over primer, including 50mm thick 0 0 0 0
extruded polystyrene boards 35KG/m3, separation 0 0 0 0
layer 140KG/m2 and finish tiles 300x300x30mm to 0 0 0 0
horizontal and vertical areas as shown and 0 0 0 0
specified in the drawings and specifications. 0 0 0 0
0 0 0 0
7.1.2 Ditto, but without roof boards along parapet LM 236 0 236 0 412 0 185 0
vertical up-stand 150 mm above from roof finish 0 0 0 0
level, including aluminum flashing 100 mm wide 0 0 0 0
and 1.5 mm thick at termination level as specified 0 0 0 0
in the drawings and specifications. 0 0 0 0
0 0 0 0
Wet Areas (Bath Rooms & Kitchens) 0 0 0 0
0 0 0 0
7.1.3 Supply, install and test of the liquid applied m2 152 0 142 0 430 0 41 0
polyurethane waterproofing type (black P.U.) to be 0 0 0 0
applied in two (2) layers 1.5 liters/m2 over the 0 0 0 0
entire flat areas including vertical and horizontal 0 0 0 0
penetrations, drains and to be self-terminated at 0 0 0 0
minimum 100 mm above the floor finish level 0 0 0 0
including separation layer, screed protection (or) 0 0 0 0
equivalent and all necessary components to 0 0 0 0
complete ready facility as specified. 0 0 0 0
0 0 0 0
Planter Boxes & Green area 0 0 0 0
Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 166/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4 0 0 0 0
Swimming Pool & Water Tanks 0 0 0 0
0 0 0 0
7.1.3 Supply, install and test of the liquid applied m2 154 0 154 0 265 0 195 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 167/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Cement based proofing 0 0 0 0
applied in two (2) layers 1.5 liters/m2 over the 0 0 0 0
entire areas including vertical and horizontal 0 0 0 0
penetrations, drains and to be self-terminated 0 0 0 0
equivalent and all necessary components to 0 0 0 0
complete ready facility as specified. 0 0 0 0

DIV#7 Total cost of this section Carried Forward To Summary - - - -

8.10 DIV#8 DOORS & WINDOWS

Supply and installation of complete doors &


windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.10 Basement Floor


Excluded- At this stage

8.20 Ground Floor


Excluded- At this stage

8.50 First Floor


Excluded- At this stage

8.60 Penthouses
Excluded- At this stage

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 168/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

DIV#8 ALUMINUM & GLAZING INCLUDING WINDOWS SHUTTERS


(separate price from main windows units)

Supply and installation of electric motor operated windows


roller shutters (unless otherwise noted), complete with all its
necessary accessories to complete ready to operate facility
with as specified in the drawings and windows schedule, as
follows:

8.70 Windows Type / Main Dewaniah B-01:


Excluded- At this stage

8.80 Windows Type / Guest Villa B-02:


Excluded- At this stage

8.90 Windows Type / Mother Villa B-03:


Excluded- At this stage

8.10 Windows Type / Abdulaziz Villa B-04:


Excluded- At this stage

8.11 Windows Type / Abdulaziz Douplex B-05:


Excluded- At this stage

8.12 Windows Type / Club House B-06:


Excluded- At this stage
8.13 Windows Type / Majid & Nasir Villa B-07:
Excluded- At this stage

8.14 Windows Type / Majid & Nasir Diwaniah B-08:


Excluded- At this stage

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 169/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
8.15 Windows Type / Adel Villa B-09:
Excluded- At this stage

8.16 Windows Type / Mohammed Villa B-10:


Excluded- At this stage

8.17 Windows Type / Abdulillah & Ibrahim Villa B-11:


Excluded- At this stage

8.18 Windows Type / Diewaniah Ibrahim B-12:


Excluded- At this stage

DIV#8 Total cost of this section Carried Forward To Summary - - - -

9.10 DIV#9 FINISHES

Plastering Works

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 998 0 1083 0 2156 0 850 0


0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 170/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
9.1.2 Plastering to walls internal sides. m2 2982 0 4189 0 5891 0 644 0
0 0 0 0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 611 0 330 0 438 0 19 0
(Painted spaces only) 0 0 0 0
0 0 0 0
9.20 Ceilings Finishes 0 0 0 0
0 0 0 0
Supply and installation of ceiling finishing with 0 0 0 0
all the necessary materials and components as 0 0 0 0
indicated in the drawings and specifications:- 0 0 0 0
0 0 0 0
Inside the building 0 0 0 0
0 0 0 0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 400 0 400 0 400 0 400 0
R.C slab. (color as to be approved by the client 0 0 0 0
or client site representative) To store and stairs . 0 0 0 0
0 0 0 0
9.2.2 Paint on Concrete m2 100 0 100 0 100 0 100 0
0 0 0 0
0 0 0 0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 100 0 100 0 100 0 100 0
0 0 0 0
9.2.12 Moisture resistant gypsum board with paint for wet area m2 100 0 100 0 100 0 100 0
0 0 0 0
0 0 0 0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 50 0 50 0 50 0 50 0
Kitchens 0 0 0 0
0 0 0 0
Outside the building 0 0 0 0
Excluded- At this stage 0 0 0 0
9.2.15 EF09 WOOD TRELLIS

Wall Finishes 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 171/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Excluded- At this stage 0 0 0 0
0 0 0 0
9.30 External Walls Surfaces 0 0 0 0
Excluded- At this stage 0 0 0 0
0 0 0 0
GRC Panels 0 0 0 0
Excluded- At this stage 0 0 0 0
0 0 0 0
9.40 Internal Walls Surfaces 0 0 0 0
0 0 0 0
9.4.1 Paint the interior walls m2 400 0 400 0 400 0 400 0
0 0 0 0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 200 0 200 0 200 0 200 0
only for Maids bathrooms 0 0 0 0

0 0 0 0
9.50 Glass Walls 0 0 0 0
Excluded- At this stage 0 0 0 0
0 0 0 0
9.60 Floor Finishes 0 0 0 0
0 0 0 0
Supply and installation of floor finishing with 0 0 0 0
skirting and all the necessary materials and 0 0 0 0
components as indicated in the drawings and 0 0 0 0
specifications:- 0 0 0 0
Only for Maids , stores 50 0 50 0 50 0 50 0
9.6.1 VITRIFIED PORCELAIN TILES (300*300*8)mm m2 50 0 50 0 50 0 50 0
0 0 0 0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 50 0 50 0 50 0 50 0
(300*300*8)mm 0 0 0 0
0 0 0 0
0 0 0 0
9.6.16 100 mm Concrete with epoxy paint layer m2 50 0 50 0 50 0 50 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 172/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
9.70 Stairs Finishes 0 0 0 0
Only for service staires 0 0 0 0
Saudi Binanco Granite - THREAD 30mm 0 0 0 0
THICK)/RISER 20MM THICK price to include 0 0 0 0
grooves for non-slip material and nose forming as 0 0 0 0
follows: 0 0 0 0
0 0 0 0
9.7.1 for Service Staircase L.M 90 0 180 0 180 0 0 0
0 0 0 0

9.7.19 Main Entrance 0 0 0 0


Excluded- At this stage

DIV#9 Total cost of this section Carried Forward To Summary - - - -

10.10 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is
incoporated in related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage

10.20 Toilet Accessories


Excluded- At this stage

10.30 MISCELLANEOUS

Stair & The Balconies and Windows Handrail

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 173/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

External Balconies
Excluded- At this stage

Internal Stair

10.3.3 Handrail to external stairs


Excluded- At this stage
10.3.4 Handrail to internal stairs LM 25 0 55 0 55 0 0
for service stair cases 0 0 0 0

Ladder 0 0 0 0
0 0 0 0
10.3.5 Internal metal ladder Radius 1 meter and 0.93 width 0 0 0 0

to connect between laundry /iron and maids lobby


0 0 0 0
complete with paint finish

0 0 0 0
10.3.6 PVC COATED STEEL LADDER RUNGS for water tanks No. 1 0 2 0 2 0 1 0
To suit water tank - HIGHT 3.3 : 3.72 0 0 0 0
0 0 0 0
Manhole Covers 0 0 0 0
0 0 0 0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 1 0 2 0 2 0 1 0
for water tanks - stone excluded on;y cover 0 0 0 0

Master Key System 0 0 0 0


Excluded- At this stage

DIV#10 Total cost of this section Carried Forward To Summary - - - -

11.10 DIV#11 EQUIPMENTS 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 174/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
NA

DIV#11 Total cost of this section Carried Forward To Summary - - - -

12.10 DIV#12 FURNITURE 0 0 0 0


NA

DIV#12 Total cost of this section Carried Forward To Summary - - - -

13.10 DIV#13 SPECIAL CONSTRUCTIONS

13.10 Sky Light


Excluded- At this stage

13.20 Fountains Works


Excluded- At this stage

13.30 SWIMMING POOL FINISH


Excluded- At this stage

13.40 SAFETY HANDRAIL PANELS


Excluded- At this stage

DIV#13 Total cost of this section Carried Forward To Summary - - - -

14.10 DIV#14 CONVEYING SYSTEM

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 175/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

14.10 LIFT / Private House & Dumpwaiter


Excluded- At this stage

DIV#14 Total cost of this section Carried Forward To Summary - - - -

15.10 DIV#15 DIVISION 15 - MECHANICAL

15.10 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 240 0 336 0 355 0 18 0
0 0 0 0
15.1.1.2 25 mm outside diameter pipe LM 180 0 67 0 96 0 45 0
0 0 0 0
15.1.1.3 32 mm outside diameter pipe LM 90 0 152 0 248 0 42 0
0 0 0 0
15.1.1.4 40 mm outside diameter pipe LM 65 0 0 0 46 0 43 0
0 0 0 0
15.1.1.5 50 mm outside diameter pipe LM 125 0 125 0 63 0 25 0
0 0 0 0
15.1.1.7 80 mm outside diameter pipe LM 10 0 6 0 6 0 5 0
0 0 0 0
Isolation Valves 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 176/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0 0 0 0
complete with all accessories and fittings, all as
specified as shown drawings.
0 0 0 0
Gate Valve 0 0 0 0
15.1.1.14 Gate vlave Ø 25 mm no 0 0 5 0 1 0 0 0
15.1.1.15 Gate vlave Ø 32 mm no 0 0 7 0 11 0 1 0
15.1.1.16 Gate vlave Ø 40 mm no 0 0 0 0 2 0 2 0
15.1.1.17 Gate vlave Ø 50 mm no 0 0 4 0 0 0 2 0
15.1.1.18 Gate vlave Ø 90 mm no 0 0 2 0 0 0 2 0
0 0 0 0
Concealed Valve 0 0 0 0
15.1.1.19 Concealed valve Ø 25 mm no 0 0 5 0 8 0 0 0
15.1.1.20 Concealed valve Ø 32 mm no 0 0 7 0 14 0 1 0
15.1.1.21 Concealed valve Ø 40 mm no 0 0 0 0 1 0 2 0
0 0 0 0
15.1.2 Electric Water Heaters 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
0 0 0 0
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings ."by Saudi
Ceramic or equivalent as per owner instructions"

0 0 0 0
15.1.2.2 EWH-2 (50 Liter) No. 9 0 18 0 16 0 1 0
0 0 0 0
15.1.2.3 EWH-3 (80 Liter ) No. 2 0 4 0 18 0 2 0
0 0 0 0
15.1.2.4 EWH-4 (100 Liter) No. 2 0 2 0 8 0 1 0
0 0 0 0
15.1.3 Domestic Cold water tank 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 177/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0 0 0 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0 0 0 0
15.1.3.1 WT- ( 8000 L ) No. 1 0 2 0 2 0 1 0
0 0 0 0
15.1.4 Ground Water Tank Accessories 0 0 0 0 0 0 0 0
0 0 0 0
Level control float switches with electric connections,
15.1.4.4 complete with but not limited to over flow alarm bell LM 2 0 2 0 4 0 2 0
and all necessary works

0 0 0 0
Bronze equilibrium ball float valve, installed connected
15.1.4.5 and tested complete with accessories as specified as LM 1 0 1 0 1 0 1 0
shown on drawings.

0 0 0 0
15.1.4.6 Vent. 65 mm diameter. No. 1 0 1 0 1 0 1 0
0 0 0 0
15.1.5 Pumps 0 0 0 0 0 0 0 0
0 0 0 0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0 0 0 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0 0 0 0
ancillary work as specified nd as shown on
drawings."Grundfos ,KSB , Aurora or equivalent as per
owner instructions"

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 1 0 2 0 2 0 1 0
0 0 0 0
15.1.6 Domestic Water Booster Set 0 0 0 0 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 178/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating valves PN 16, lug and , strainer PN
16, flexible connections, concrete inertia pad, house
pad, vibration eliminator pad, low level control float
switches, pressure switch dry run protection and 0 0 0 0
controls all supplied from pump manufacturer
diaphragm tank (s), food quality synthetic rubber
membrane, steel painted body, working pressure 10
bars with isolating valve and pressure gauge, electric
connections, wiring and accessories all as specified and
shown on the drawings. "Grundfos ,KSB , Aurora or
equivalent as per owner instructions"

0 0 0 0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 1 0 0 0 0 0 0 0
0 0 0 0
15.1.6.2 BP-2 (35 GPM /43 FT) Set 0 0 2 0 0 0 1 0
0 0 0 0
15.1.6.3 BP-3 (55 GPM /43 ft) Set 0 0 0 0 2 0 0 0
0 0 0 0
15.20 FIRE FIGHTING SYSTEM 0 0 0 0 0 0 0 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0 0 0 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0 0 0 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 7 0 12 0 14 0 2 0


0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 179/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0 0 0 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 3 0 6 0 7 0 1 0


0 0 0 0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0 0 0 0
per owner instructions"

15.2.3 Fire blanket No. 3 0 6 0 7 0 1 0


0 0 0 0
15.30 PLUMBING FIXTURE APPLIANCES 0 0 0 0 0 0 0 0
0 0 0 0
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains
0 0 0 0
including adapters, branches, tees, valves, supports
from galvanized steel, brackets, hangers ,shelves,
siphon, terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications
0 0 0 0
Water Closet

Western type vitreous china water cloSet complete


with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0 0 0 0
connection as specified.

WC-01 ( Supply and install ) for Maids rooms (ideal


15.3.1.1 No. 0 0 2 0 4 0 0 0
standard or equivlant)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 180/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
install only ,connection and testing wall mounted WC
complete with but not limited to concealed
tank with actuator flush panel or pneumatic
push button for washdown wall-hung toilets and
Chrome hand spry Include adjustable wall bracket with
min. 1.2 m hose
System shall fit within minimum 51
⁄2" (146 mm) framing wall or plumbing chase, with
steel framing members Framing members
should be capable of supporting 400 kg load without
damage to the wall. Water
supply shall have minimum flow
pressure of 2 PSI (0.01 MPa). The toilet bowl
0 0 0 0
shall be a third party listed low-consumption
1.6/0.8 GPF (6/3 LPF) dualflush
2-hole wall-hung type. The carrier frame
shall be adjustable for bowl rim heights from
15" to 19" (381 to 483 mm). Actuator flush
panels shall be diecast zinc, molded plastic or
fabricated stainless steel and plated to
preserve material integrity. All components
shall be compliant with applicable codes and
product standards.

WC-02 Install Only ( Fixtures Purchase by Client -Part


15.3.1.2 No. 0 0 12 0 26 0 4 0
of ID )

0 0 0 0
Lavatories
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer and 800x900mm wall 0 0 0 0
mirror with chamfered edge including all the necessary
fittings & accessories and approved by the owner .

( Lav-01 ) ( Supply and install for Maids rooms ( ideal


15.3.2.1 standard inclusive of water mixer grohe or equivlant ) No. 0 0 2 0 46 0 0 0

Supply ,install ,connection and testing for recessed


mounted Lavatories complete including wash basin 0 0 0 0
mixer with but not limited to hangers support
(galvanized steel made)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 181/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
15.3.2.2 ( Lav-02 ) Install Only ( Fixtures Purchase by Client No. 0 0 18 0 4 0 10 0
-Part of ID )

Bathtub
Supply and install bathtub ,complete, including water
feed, waste and vent branch piping works to mains
including adapters, branches, tees, valves, mixer,
supports, brackets, hangers , siphon ..etc. all as
specifications, drawings and water consumption 0 0 0 0
rationalization specifications all model must approved
from owner representative and consultant. only as
required for fixture installation and to wall connection .
BT-02 Install ony ( Fixture Purchase by Client -Part of
15.3.3.2 No. 4 0 4 0 5 0 0 0
ID )
0 0 0 0
kitchen sink 0 0 0 0
Excluded- At this stage 0 0 0 0
0 0 0 0
Shower Hand mixer 0 0 0 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (as per owner 0 0 0 0
representative and consultant.)
0 0 0 0
15.3.9.1 SH-01 (sypply and install) grohe Type or equivalent . No. 0 0 0 0 2 0 0 0
0 0 0 0
15.3.9.2 SH-02 Install Only ( Fixtures Purchase by Client -Part of No. 0 0 6 0 18 0 2 0
ID )
0 0 0 0
15.40 STORMWATER AND DRAINAGE SYSTEM 0 0 0 0 0 0 0 0
0 0 0 0
15.4.1 Pipework 0 0 0 0 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 182/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0 0 0 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0 0 0 0
15.4.1.1 50 mm diameter pipe LM 46 0 100 0 92 0 18 0
0 0 0 0
15.4.1.2 80 mm diameter pipe LM 210 0 260 0 336 0 29 0
0 0 0 0
15.4.1.3 110 mm diameter pipe LM 260 0 210 0 900 0 21 0
0 0 0 0
15.4.1.4 160 mm diameter pipe LM 0 0 0 0 0 0 0 0
0 0 0 0
0 0 0 0
Floor Drain 0 0 0 0
0 0 0 0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0 0 0 0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0 0 0 0
15.4.1.5 FD-80 mm outlet diameter No. 17 0 30 0 54 0 8 0
0 0 0 0
0 0 0 0
Floor Cleanout 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 183/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0 0 0 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0 0 0 0
15.4.1.7 FCO- 110mm No. 7 0 4 0 26 0 1 0
0 0 0 0
15.4.1.8 WCO- 110mm No. 0 0 0 0 0 0 0 0
0 0 0 0
Trench Drain 0 0 0 0
0 0 0 0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as 0 0 0 0
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 2 0 4 0 14 0 1 0


Inspection room 0 0 0 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and No. 0 0 1 0 0 0 3 0
as shown on drawings .

0 0 0 0
Gully trap 0 0 0 0
Constructing , connecting and testing Gully trap
complete with heavy duty cast iron cover and all other
accessories all as specifications and as shown on
15.4.1.9.2 No. 0 0 1 0 0 0 3 0
drawings

0 0 0 0
Submersible Pumps 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 184/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0 0 0 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-01 (35 GPM / 18 FT )
15.4.1.10 set 0 0 0 0 2 0 1 0

0 0 0 0
Roof Drain 0 0 0 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0 0 0 0
with accessories all as specified and shown on drawing.

0 0 0 0
15.4.1.15 RD, 110mm outlet diameter No. 8 0 8 0 14 0 4 0
0 0 0 0
15.4.1.16 RD, 75mm outlet diameter No. 0 0 0 0 0 0 0 0
0 0 0 0
Down spout 0 0 0 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0 0 0 0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 2 0 8 0 6 0 4 0


0 0 0 0
0 0 0 0
0 0 0 0
Roof Vent Cap 0 0 0 0
0 0 0 0
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner 0 0 0 0
instructions"

15.4.1.19 Type RVC, 110 mm diameter pipe No. 15 0 12 0 24 0 6 0


0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 185/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

15.50 HVAC SYSTEM 0 0 0 0 0 0 0 0


BUILDER'S WORK RELATED TO MECHANICAL
0 0 0 0
WORKS
0 0 0 0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 1 0 1 0 1 0 1 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0 0 0 0
LABELING AND IDENTIFYING 0 0 0 0
0 0 0 0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 1 0 1 0 1 0 1 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0 0 0 0
15.5.3 AIR CONDITIONERS UNITS 0 0 0 0 0 0 0 0
0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 186/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, test and commission Packaged roof
mounted air-condition unit, (HEAT PUMP TYPE)
according to the following specifications : Heavy gauge
galv. Steel sheet, with electrostatic powder paint of
epoxy coating finish. Double skin unit casing with
suitable thermal insulation, Weather proof, Hermetic
sealed scroll compressors Refrigerant , Micro processor
controller, Return fan and supply fan, Aluminum Flat
Filter, Economizer section, Mixing box with
automatically operated fresh air damper, External
overload protections for all compressors and circuit
breaker for the unit. Evaporator coil and condenser coil
15.5.3.1 made of copper tubes and aluminum fins, Thermal 0 0 0 0 0 0 0 0
expansion valve, Gas control, Filter driers, Sight glass,
Solenoid valves; High and low pressure cutouts; Oil
pressure switches; Air and fire dampers. Drain system
for condensate water Anti vibration pads; Concrete
bases; Inside air temperature controlling according to
ASHRAE standards and All electrical wiring and
conduits required, Kinetic Float Base, Equipment
capacities as tabulated on the drawings. By Daikin
manuf. or equivelant

15.5.3.1.4 PAC-04 6TR No. 0 0 0 0 0 0 1 0


0 0 0 0
15.5.3.1.5 PAC-05 7.5TR No. 0 0 0 0 0 0 1 0
0 0 0 0
15.5.3.1.6 PAC-06 8.5TR No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.3.1.7 PAC-07 - 10TR No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.3.1.9 PAC-09 - 15TR No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.3.1.10 PAC-10 24TR No. 0 0 0 0 0 0 0 0
0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 187/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
power connections between the isolator switch and the
15.5.3.2 outdoor unit, vibration isolators, hangers for the indoor 0 0 0 0 0 0 0 0
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Concealed Type - for Vills 0 0 0 0


15.5.3.2.1.1 FCU-01 - 1.5TR 5 0 0 0 9 0 0 0
0 0 0 0
15.5.3.2.1.2 FCU-02 - 2TR 0 0 4 0 9 0 0 0
0 0 0 0
15.5.3.2.1.3 FCU-03 - 2.5TR 4 0 4 0 1 0 1 0
0 0 0 0
15.5.3.2.1.4 FCU-04 - 3TR 2 0 2 0 5 0 0 0
0 0 0 0
15.5.3.2.1.5 FCU-05 - 3.5TR 6 0 4 0 7 0 0 0
0 0 0 0
15.5.3.2.1.6 FCU-06 - 4TR 0 0 0 0 6 0 0 0
0 0 0 0
15.5.3.2.1.8 FCU-08 - 5TR 4 0 2 0 3 0 1 0
0 0 0 0
Cassette units - for Kitchens 0 0 0 0
0 0 0 0
15.5.3.2.1.9 CDX-01 -1.5TR 1 0 0 0 1 0 0 0
0 0 0 0
15.5.3.2.1.10 CDX-02 - 2TR 1 0 0 0 2 0 0 0
0 0 0 0
15.5.3.2.1.11 CDx-03 -2.5TR 0 0 0 0 2 0 0 0
0 0 0 0
Split Wall mounted Type - For service Drivers , 0 0 0 0
Maid stores .. 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 188/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
15.5.3.2.1.12 WDX-01 -1TR 4 0 4 0 9 0 1 0
0 0 0 0
15.5.3.2.1.13 WDX-02 -1.5TR 2 0 6 0 1 0 1 0
0 0 0 0
0 0 0 0
15.5.3.3 Refrigeration Unit Type 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install, test and commission refrigeration unit
type with appropriate compressors, evaporators,
refrigeration gas and all components and accessories. 0 0 0 0

0 0 0 0
15.5.3.3.1 Ref. ROU-01 / RIU-01 -Ref. ROU-B02-1 / RIU-B02-1 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.3.3.2 Ref. ROU-02 / RIU-02 -Ref. ROU-B02-2 / RIU-B02-2 No. 0 0 0 0 0 0 0 0
0 0 0 0
0 0 0 0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0 0 0 0 0 0 0 0

0 0 0 0
Supply, install, test and commission centrifugal in line/
roof mounted (Roof Top Type) belt drive exhaust fan
with external motor installation for kitchen hoods, fans
shall be able to operate for no less than one hour at
high temperature , complete with steel bases, steel
box, frames, rubber pads, sealers for leakage, access
panels , flexible connections with ducts, guard screens,
back draft damper with all fixing, support, grease 0 0 0 0
drain , and all required accessories and all required
accessories for proper installation and as per specs &
dwgs. "suadi fans , greenheck, ASEM or equivalent as
per owner instructions"

15.5.4.1 HEF-B01-G-01 No. 0 0 0 0 0 0 0 0


0 0 0 0
15.5.4.2 HEF-B02-B-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.4 HEF-B02-B-02 No. 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 189/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
15.5.4.4.1 HEF-B02-B-03 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.5 HEF-B03-B-01 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.6 HEF-B03-G-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.7 HEF-B03-FR-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.8 HEF-B04-B-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.9 HEF-B04-G-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.10 HEF-B04-G-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.11 HEF-B07-B-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.12 HEF-B07-B-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.13 HEF-B07-B-03 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.14 HEF-B09-B-01 No. 1 0 0 0 0 0 0 0
0 0 0 0
15.5.4.14.1 HEF-B10-B-01 No. 0 0 1 0 0 0 0 0
0 0 0 0
15.5.4.14.2 HEF-B10-B-02 No. 0 0 1 0 0 0 0 0
0 0 0 0
15.5.4.15 HEF-B11-B-01 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.16 HEF-B11-B-02 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.17 HEF-B11-B-03 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.18 HEF-B11-B-04 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.19 HEF-B11-B-05 No. 0 0 0 0 1 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 190/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0 0 0 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

Fan Section (belt driven) 0 0 0 0


0 0 0 0
15.5.4.20 MAF-B02-B-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.21 MAF-B02-B-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.22 MAF-B07-B-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.23 MAF-B07-B-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.24 MAF-B07-B-03 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.25 MAF-B11-B-01 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.26 MAF-B11-B-02 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.27 FAF-B01-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.30 FAF-B03-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.31 FAF-B04-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.32 FAF-B05-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.33 FAF-B05-02 No. 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 191/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
15.5.4.34 FAF-B07-B-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.35 FAF-B07-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.36 FAF-B07-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.37 FAF-B08-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.38 FAF-B09-01 No. 1 0 0 0 0 0 0 0
0 0 0 0
15.5.4.39 FAF-B10-01 No. 0 0 2 0 0 0 0 0
0 0 0 0
15.5.4.40 FAF-B10-02 No. 0 0 2 0 0 0 0 0
0 0 0 0
15.5.4.41 FAF-B11-01 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.42 FAF-B11-02 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.43 FAF-B12-G-01 No. 0 0 0 0 0 0 1 0
0 0 0 0
0 0 0 0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0 0 0 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0 0 0 0
0 0 0 0
15.5.4.45 EXF-B01-B-02 ( Roof top ) No. 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 192/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
15.5.4.46 EXF-B01-B-03( Roof top ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.47 EXF-B01-G-01( Roof top ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.48 EXF-B01-G-02( Roof top ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.52 EXF-B02-B-01( Roof top ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.53 EXF-B02-B-02( Roof top ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.54 EXF-B02-B-03( IN LINE ) No. 0 0 0 0 0 0 0 0
0 0 0 0
0 0 0 0
15.5.4.55 Ditto but Centrifugal in line fan 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.56 EXF-B02-G-02( IN LINE ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.57 EXF-B02-G-03( IN LINE ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.58 EXF-B02-G-04( IN LINE ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.59 EXF-B02-G-05( IN LINE ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.60 EXF-B02-G-06( IN LINE ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.61 EXF-B02-G-07( IN LINE ) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.62 EXF-B06-B-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.63 EXF-B06-G-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.64 EXF-B06-G-02 No. 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 193/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
15.5.4.65 EXF-B06-G-03 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.66 EXF-B06-G-04 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.67 EXF-B07-B-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.68 EXF-B07-B-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.69 EXF-B07-B-03 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.70 EXF-B07-B-04 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.71 EXF-B07-B-05 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.72 EXF-B07-F-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.73 EXF-PAC-B07-01(INLINE) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.75 EXF-B08-G-01(INLINE) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.76 EXF-PAC-B08-01(INLINE) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.77 EXF-PAC-B08-02(INLINE) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.78 EXF-PAC-B08-03(INLINE) No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.82 EXF-PAC-B11-01(INLINE) No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.4.83 EXF-B12-G-01 No. 0 0 0 0 0 0 1 0
0 0 0 0
15.5.4.84 EXF-B12-G-02 No. 0 0 0 0 0 0 1 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 194/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
15.5.4.85 EXF-PAC-B12-01 No. 0 0 0 0 0 0 1 0
0 0 0 0
15.5.4.86 EXF-PAC-B12-02 No. 0 0 0 0 0 0 1 0
0 0 0 0
15.5.4.90.1 AEX-B02-01 NO 0 0 0 0 0 0 0 0
15.5.4.90.2 AEX-B04-02 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0 0 0 0
greenheck, ASEM or equivalent as per owner
instructions"
0 0 0 0
15.5.4.91 CEX-01 No. 13 0 18 0 13 0 1 0
15.5.4.92 CEX-02 No. 4 0 8 0 8 0 1 0
0 0 0 0
Supply, install test & commission air curtain all
required accessories as per specs and schedule . 0 0 0 0

0 0 0 0
15.5.4.93 AC-01 No. 0 0 0 0 0 0 2 0
15.5.4.94 AC-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0 0 0 0
greenheck, ASEM or equivalent as per owner
instructions"
0 0 0 0
15.5.4.95 WEX-B02-01 NO 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.96 WEX-B03-01 NO 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.97 WEX-B04-01 NO 0 0 0 0 0 0 0 0
0 0 0 0
15.5.4.98 WEX-B06-01 0 0 0 0 0 0 0 0
0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 195/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

15.5.5 Condensate Pipework 0 0 0 0 0 0 0 0


0 0 0 0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick 0 0 0 0
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0 0 0 0
15.5.5.1 25 mm outside diameter pipe LM 261 0 170 0 495 0 36 0
0 0 0 0
15.5.5.4 50mm outside diameter pipe LM 0 0 0 0 15 0 40 0
0 0 0 0
15.5.6 Ductwork 0 0 0 0 0 0 0 0
0 0 0 0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 3670 0 1760 0 8524 0 1219 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 196/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 1 0 2 0 5 0 0 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0 0 0 0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 1 0 2 0 5 0 0 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0 0 0 0
Supply ,install ,connect ,test and commission
protection, aluminum cladding for external duct,
15.5.6.4 kg 0 0 88 0 0
complete with but not limited to all acessories , flow
indicators, labels, color code stickers,….etc
0 0 0 0
15.5.7 Ductwork Insulation 0 0 0 0 0 0 0 0
0 0 0 0

Supply, install, connect, test and commission


Fiberglass blanket duct insulation for supply, fresh air
and return ductwork, Fiberglass insulation 25mm thick
density 24kg/m3, factory laminated to a reinforced foil
15.5.7.1 Kraft vapour barrier facing covered with canvas fabric m2 604 0 320 0 1371 0 186 0
wrap and two layers of fungus resistant mastic,
installed connected and tested complete including self
adhesive fixing pins, sealing tape, wire banding and
accessories all as specified and shown on drawings.

0 0 0 0
15.5.7.2 Ditto but with thikness 50 mm and 48 kg/m³ desity m2 0 0 28 0 0
0 0 0 0
15.5.8 Duct Acoustic Inner Liner 0 0 0 0 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 197/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, connect, test and commission Duct


acoustic inner liner Rubber insulation thickness 13 mm
fixed with fire resistant adhesive and mechanical
15.5.8.1 LS 1 0 1 0 0 0 1 0
fasteners, installed, connected and tested complete
with accessories, to meet NC as specified and shown
on drawings.

0 0 0 0
15.5.9 Air Diffusers, Registers, and Grilles 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install, connect, test and commission, Supply
Linear Slotting Diffuser as per drawings, complete with
volume dampers, insulated plenum box and including 0 0 0 0
all accessories to complete the work.. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

0 0 0 0
15.5.9.1 SLD - 1 LM 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.2 SLD - 2 LM 19 0 0 0 0 0 0 0
0 0 0 0
15.5.9.3 SLD - 3 LM 41 0 0 0 38 0 0 0
0 0 0 0
15.5.9.4 SLD - 4 LM 12 0 0 0 85 0 25 0
0 0 0 0
15.5.9.5 SLD - 5 LM 37 0 72 0 53 0 8 0
0 0 0 0
15.5.9.6 SLD - 6 LM 0 0 8 0 14 0 0 0
0 0 0 0
15.5.9.7 SLD - 7 LM 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.8 SLD - 8 LM 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install, connect, test and commission,Return
and installation of return Linear Slotting Diffuser as per
drawings, complete with volume dampers, insulated
plenum box and including all accessories to complete 0 0 0 0
the work.

15.5.9.9 RLD - 1 LM 0 0 0 0 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 198/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
15.5.9.10 RLD - 2 LM 14 0 0 0 0 0 0 0
0 0 0 0
15.5.9.11 RLD - 3 LM 10 0 0 0 38 0 0 0
0 0 0 0
15.5.9.12 RLD - 4 LM 12 0 0 0 85 0 25 0
0 0 0 0
15.5.9.13 RLD - 5 LM 63 0 72 0 53 0 8 0
0 0 0 0
15.5.9.14 RLD - 6 LM 0 0 8 0 13 0 0 0
0 0 0 0
15.5.9.15 RLD - 7 LM 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.16 RLD - 8 LM 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install, connect, test and commission, powder
coated aluminum register air grill with opposed blade
dampers , color to be selected by the Engineer,
including connections to ductwork with plenum box
0 0 0 0
and flexible duct, volume damper for balancing
purposes, mounting, fixings and all required
accessories as per specs and drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0 0 0 0
15.5.9.17 SR-01 No. 0 0 0 0 0 0 0 0

Diito as above But Return Rabeea, GGC, Beta, or


equivalent as per owner instructions" 0 0 0 0

15.5.9.18 RR-01 No. 0 0 0 0 0 0 0 0


0 0 0 0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0 0 0 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0 0 0 0
15.5.9.19 EG-01 No. 0 0 0 0 11 0 5 0
0 0 0 0
15.5.9.20 EG-02 No. 0 0 0 0 1 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 199/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0 0 0 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0 0 0 0
0 0 0 0
0 0 0 0
15.5.9.46 EAL-B02-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.48 EAL-B02-04 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.52 EAL-B06-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.53 EAL-B06-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.54 EAL-B06-03 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.55 EAL-B07-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.58 EAL-B07-04 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.59 EAL-B07-05 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.60 EAL-B08-01 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.61 EAL-B08-02 No. 0 0 0 0 0 0 0 0
0 0 0 0
15.5.9.63 EAL-B11-01 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.9.64 EAL-B11-02 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.9.65 EAL-B11-03 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.9.66 EAL-B11-04 No. 0 0 0 0 1 0 0 0
0 0 0 0
15.5.9.67 EAL-B12-02 No. 0 0 0 0 0 0 4 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 200/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
0 0 0 0
15.60 LPG SYSTEM 0 0 0 0 0 0 0 0
0 0 0 0
15.6.1 Pipework 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install test & commission, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions" Schedule 40 - inside buildings 0 0 0 0

only for diwanyah and Guest villa 0 0 0 0


15.6.1.1 25 mm diameter pipe LM 0 0 0 0 0 0 0 0
0 0 0 0
15.6.1.2 32 mm diameter pipe LM 0 0 0 0 0 0 0 0
0 0 0 0
15.6.1.3 40 mm diameter pipe LM 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install & test PVC coated Copper pipes for gas
system, complete with fittings & all related works
(valves at termination points to be included in the 0 0 0 0
rate).APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"
15.6.1.4 20 mm diameter pipe LM 0 0 0 0 0 0 0 0
0 0 0 0
15.6.2 Gas Valves 0 0 0 0 0 0 0 0
0 0 0 0
Supply Isolating ball valves, quarter-turn, installed,
connected, and tested complete including all 0 0 0 0
accessories, all as specified and shown on drawings.
15.6.2.1 20 mm diameter No. 0 0 0 0 0 0 0 0
0 0 0 0
15.6.3 Solenoid Gas Valves 0 0 0 0 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 201/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply Solenoid gas valves, installed, connected, and
tested, complete including all accessories as specified 0 0 0 0
and shown on drawings.
0 0 0 0
15.6.3.1 40 mm diameter No. 0 0 0 0 0 0 0 0
0 0 0 0
15.6.4 Gas Regulators 0 0 0 0 0 0 0 0
0 0 0 0
Gas regulators, installed, connected, and tested
complete with isolating valve, including all accessories 0 0 0 0
as specified and shown on drawings.
0 0 0 0
15.6.4.1 32 mm diameter No. 0 0 0 0 0 0 0 0
0 0 0 0
15.6.6 Gas Manifold 0 0 0 0 0 0 0 0
0 0 0 0
Supply Gas manifold, installed, tested, complete with
steel cabinets, branch gas valves and accessories, all
as specified and shown on drawings. 0 0 0 0

0 0 0 0
15.6.6.1 Gas Manifold No. 0 0 0 0 0 0 0 0
0 0 0 0
0 0 0 0

SWIMMING POOL SYSTEM AND FOUNTAINS 0 0 0 0 0 0 0 0


15.70
0 0 0 0
15.7.1 PVC Pipes 0 0 0 0 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 202/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0 0 0 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0 0 0 0
15.7.1.5 63 mm LM 0 0 0 0 50 0 50 0
0 0 0 0
15.7.1.6 75 mm LM 0 0 0 0 20 0 20 0
0 0 0 0
15.7.1.7 110 mm LM 0 0 0 0 20 0 20 0
0 0 0 0
15.7.1.8 160mm LM 0 0 0 0 0 0 0 0
0 0 0 0
15.7.2 Swimming pool pump 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0 0 0 0

15.7.2.4 FP-B07-1 No. 0 0 0 0 0 0 0 0


0 0 0 0
15.7.2.5 FP-B11-1 No. 0 0 0 0 2 0 0 0
0 0 0 0
15.7.2.6 FP-B12-1 No. 0 0 0 0 0 0 2 0
0 0 0 0
15.7.3 Inlet Fitting 0 0 0 0 0 0 0 0
0 0 0 0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0 0 0 0
specified and shown on drawings

0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 203/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0 0 0 0 3 0 3 0


15.7.4 Vacuum Fitting 0 0 0 0 0 0 0 0
0 0 0 0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0 0 0 0
drawings

0 0 0 0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0 0 0 0 1 0 1 0
0 0 0 0
15.7.5 Main Drain 0 0 0 0 0 0 0 0
0 0 0 0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0 0 0 0
shown on drawings
0 0 0 0
15.7.5.1 Main drain MD No. 0 0 0 0 2 0 2 0
0 0 0 0
15.7.6 Overflow Trench Fitting 0 0 0 0 0 0 0 0
0 0 0 0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0 0 0 0
spesified and shown on drawings.

0 0 0 0
15.7.6.1 Overflow Trench LM 0 0 0 0 30 0 30 0
0 0 0 0
15.7.7 Outlet Fitting 0 0 0 0 0 0 0 0
0 0 0 0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
0 0 0 0
specified and shown on drawings

0 0 0 0
15.7.7.1 Outlet fitting 75mm diameter No. 0 0 0 0 3 0 2 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 204/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
15.7.8 Fill Fitting 0 0 0 0 0 0 0 0
0 0 0 0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0 0 0 0

0 0 0 0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0 0 0 0 1 0 1 0
0 0 0 0
15.7.9 Pool Sand Filter 0 0 0 0 0 0 0 0
0 0 0 0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0 0 0 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

15.7.9.1 SF-B07-1 No. 0 0 0 0 0 0 0 0


0 0 0 0
15.7.9.2 SF-B11-1 Set. 0 0 0 0 1 0 0 0
0 0 0 0
15.7.9.3 SF-B12-1 Set. 0 0 0 0 0 0 1 0
0 0 0 0
15.7.10 Chemical Feeding and Control Accessories 0 0 0 0 0 0 0 0
0 0 0 0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0 0 0 0

0 0 0 0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0 0 0 0 1 0 1 0
0 0 0 0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0 0 0 0

0 0 0 0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0 0 0 0 1 0 1 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 205/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

15.7.10.3 Chemical test kit No. 0 0 0 0 1 0 1 0


0 0 0 0
15.7.11 Balance Tank 0 0 0 0 0 0 0 0
0 0 0 0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0 0 0 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0 0 0 0
Capacity (4) m3 0 0 0 0
15.7.11.1.1 BT-B07-1 No. 0 0 0 0 0 0 0 0
15.7.11.1.2 BT-B11-1 No. 0 0 0 0 1 0 0 0
15.7.11.1.3 BT-B12-1 No. 0 0 0 0 0 0 1 0
0 0 0 0
15.7.12 Electrical Heat Exchanger 0 0 0 0 0 0 0 0
0 0 0 0
Supply Stainless steel pool heat exchanger, installed 0 0 0 0
and tested complete with Digital Thermostat, valves, 0 0 0 0
control valve & all related works as specified and 0 0 0 0
shown on drawings. 0 0 0 0
0 0 0 0
Pool Heat Exchanger H.X 0 0 0 0
15.7.12.1 P- HE-01 (21 KW) No. 0 0 0 0 1 0 0 0
0 0 0 0
15.7.12.2 P- HE-02 (30 KW) No. 0 0 0 0 0 0 1 0
0 0 0 0
0 0 0 0
DIV#15 Total cost of this section Carried Forward To Summary - - - -

16.10 DIV#16 ELECTRICAL WORKS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 206/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.1.1 Ref. SMDB-DW No. 0 0 0 0 0 0 0 0


16.1.2 Ref. SMDB-G.V No. 0 0 0 0 0 0 0 0
16.1.3 Ref. ESMDB-G.V No. 0 0 0 0 0 0 0 0
16.1.4 Ref. SMDB-M.V No. 0 0 0 0 0 0 0 0
16.1.5 Ref. SMDB-A.V No. 0 0 0 0 0 0 0 0
16.1.6 Ref. SMDB-D.A/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0 0
16.1.7 Ref. SMDB-C.H No. 0 0 0 0 0 0 0 0
16.1.8 Ref. ESMDB-C.H No. 0 0 0 0 0 0 0 0
16.1.9 Ref. SMDB-MA No. 0 0 0 0 0 0 0 0
16.1.10 Ref. ESMDB-MA No. 0 0 0 0 0 0 0 0
16.1.11 Ref. SMDB-NA No. 0 0 0 0 0 0 0 0
16.1.12 Ref. SMDB-DM&N No. 0 0 0 0 0 0 0 0
16.1.13 Ref. SMDB-A'A.V No. 1 0 0 0 0 0 0 0
16.1.14 Ref. SMDB-M.V/X (X: R, L) No. 0 0 2 0 0 0 0 0
16.1.15 Ref. SMDB-DI&A No. 0 0 0 0 0 0 1 0
16.1.16 Ref. SMDB-I No. 0 0 0 0 1 0 0 0
16.1.17 Ref. SMDB-AE No. 0 0 0 0 1 0 0 0
0 0 0 0
16.20 Motor Control Center 0 0 0 0 0 0 0 0
Section 16443 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 207/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0 0 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

0 0 0 0
0 0 0 0
0 0 0 0
16.2.1 Ref. MCC-R No. 1 0 0 0 1 0 1 0
16.2.1.1 Ref. MCC-R/I No. 0 0 0 0 1 0 0 0
16.2.2 Ref. EMCC-R No. 0 0 0 0 0 0 0 0
16.2.3 Ref. MCC-R/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0 0
16.2.4 Ref. MCC-R1/M No. 0 0 0 0 0 0 0 0
16.2.5 Ref. MCC-R2/M No. 0 0 0 0 0 0 0 0
16.2.6 Ref. MCC-P/M No. 0 0 0 0 0 0 0 0
16.2.7 Ref. MCC-R1/N No. 0 0 0 0 0 0 0 0
16.2.8 Ref. MCC-R2/N No. 0 0 0 0 0 0 0 0
16.2.9 Ref. MCC-P/N No. 0 0 0 0 0 0 0 0
16.2.10 Ref. MCC-R/X (X: R, L) No. 0 0 2 0 0 0 0 0
0 0 0 0
16.30 Distribution Boards 0 0 0 0 0 0 0 0
16.3.1 Ref. DB-B No. 1 0 0 0 0 0 1 0
16.3.2 Ref. DB-G No. 1 0 0 0 0 0 0 0
16.3.3 Ref. DB-F No. 1 0 0 0 1 0 0 0
16.3.3.1 Ref. DB-F/AE 0 0 0 0 1 0 0 0
16.3.4 Ref. DB-R No. 1 0 0 0 1 0 0 0
16.3.4.1 Ref. DB-R/AE 0 0 0 0 1 0 0 0
16.3.5 Ref. EDB-G/I No. 0 0 0 0 1 0 0 0
16.3.5.1 Ref. EDB-G/AE 0 0 0 0 1 0 0 0
16.3.6 Ref. EDB-F No. 0 0 0 0 2 0 0 0
16.3.8 Ref. DP-B/I No. 0 0 0 0 1 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 208/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
16.3.8.1 Ref. DP-B/AE No. 0 0 0 0 1 0 0 0
16.3.9 Ref. DL-B No. 0 0 0 0 0 0 0 0
16.3.10 Ref. EDB-B No. 1 0 0 0 0 0 1 0
16.3.10.1 Ref. DB-G-DI&A 0 0 0 0 2 0 1 0
16.3.11 Ref. EDB-K No. 0 0 0 0 0 0 0 0
16.3.12 Ref. DP-G No. 0 0 0 0 0 0 0 0
16.3.13 Ref. DL-G No. 0 0 0 0 0 0 0 0
16.3.14 Ref. EDB-G No. 0 0 0 0 0 0 0 0
16.3.15 Ref. DP-F No. 0 0 0 0 0 0 0 0
16.3.16 Ref. DL-F No. 0 0 0 0 0 0 0 0
16.3.17 Ref. DB-B/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0 0
16.3.18 Ref. DB-G/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0 0
16.3.19 Ref. DB-F/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0 0
16.3.23 Ref. DB-R/X (X: R/1, L/1, R/2, L/2) No. 0 0 0 0 0 0 0 0
16.3.24 Ref. DB-GR No. 0 0 0 0 0 0 0 0
16.3.25 Ref. DB-GL No. 0 0 0 0 0 0 0 0
16.3.26 Ref. DB-EX No. 0 0 0 0 0 0 0 0
16.3.27 Ref. DB-SM No. 0 0 0 0 0 0 0 0
16.3.28 Ref. EDB-S No. 0 0 0 0 0 0 0 0
16.3.29 Ref. DB-GM No. 0 0 0 0 0 0 0 0
16.3.30 Ref. EDB-GM No. 0 0 0 0 0 0 0 0
16.3.31 Ref. DB-FM No. 0 0 0 0 0 0 0 0
16.3.32 Ref. DB-RM No. 0 0 0 0 0 0 0 0
16.3.33 Ref. DB-KM No. 0 0 0 0 0 0 0 0
16.3.34 Ref. EDB-KM No. 0 0 0 0 0 0 0 0
16.3.35 Ref. DB-SP No. 0 0 0 0 0 0 0 0
16.3.36 Ref. DB-SL No. 0 0 0 0 0 0 0 0
16.3.37 Ref. DB-KN No. 0 0 0 0 0 0 0 0
16.3.38 Ref. EDB-KN No. 0 0 0 0 0 0 0 0
16.3.39 Ref. DB-GN No. 0 0 0 0 0 0 0 0
16.3.40 Ref. DB-FN No. 0 0 0 0 0 0 0 0
16.3.41 Ref. DB-RN No. 0 0 0 0 0 0 0 0
16.3.42 Ref. EDB-GN No. 0 0 0 0 1 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 209/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
16.3.43 Ref. DB-B/S No. 0 0 0 0 0 0 0 0
16.3.44 Ref. EDB-S No. 0 0 0 0 0 0 0 0
16.3.45 Ref.DB-DM&N No. 0 0 0 0 0 0 0 0
16.3.46 Ref.EDB-DM&N No. 0 0 2 0 0 0 0 0
16.3.47 Ref. DB-B/X (X: R, L) No. 0 0 2 0 0 0 0 0
16.3.48 Ref. DB-G/X (X: R, L) No. 0 0 2 0 0 0 0 0
16.3.49 Ref. DB-F/X (X: R, L) No. 0 0 2 0 0 0 0 0
16.3.50 Ref. EDB-B/X (X: R, L) No. 0 0 2 0 0 0 0 0
16.3.51 Ref. DB-K/X (X: R, L) No. 0 0 2 0 0 0 0 0
16.3.52 Ref. DB-R/X (X: R, L) No. 0 0 0 0 0 0 0 0
0 0 0 0
16.40 Feeders 0 0 0 0 0 0 0 0
Section 16122 0 0 0 0

Feeders, conductors and cables including all necessary


supports, brackets, pipes, cable trayes (where needed) ,
conduits, manholes (if needed), luges, glands, cable 0 0 0
terminaL.S , terminations and electrical connections and
all needed accessories as shown on the drawings.

0 0 0 0
16.4.1 2(4x240) mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 300 0 0 0
16.4.4 4x300mm² CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0 0
16.4.5 4x240 mm2 CU/XLPE/SWA/PVC LM 90 0 220 0 0 0 0 0
16.4.6 4x185 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 25 0 0 0
16.4.7 4x150 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0 0
16.4.8 4x120 mm2 CU/XLPE/SWA/PVC LM 0 0 50 0 0 0 0 0
16.4.9 4x70 mm2 CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 70 0
16.4.10 4x240mm² CU/XLPE/PVC + 1x120mm² Y/G PVC CABLE LM 0 0 0 0 25 0 0 0
16.4.11 4x150mm² CU/XLPE/PVC + 1x70mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0 0
16.4.12 4x120mm² CU/XLPE/PVC + 1x70mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0 0
16.4.13 4x95mm² CU/XLPE/PVC + 1x50mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0 0
16.4.14 4x70mm² CU/XLPE/PVC + 1x35mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0 0
16.4.15 4x50mm² CU/XLPE/PVC + 1x25mm² Y/G PVC CABLE LM 0 0 0 0 0 0 10 0

16.4.16 4x25mm² CU/XLPE/SWA/PVC + 1x16mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 210/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
16.4.17 4x35mm² CU/XLPE/SWA/PVC LM 0 0 0 0 0 0 0 0

16.4.19 4x10mm² CU/XLPE/SWA/PVC + 1x10mm² Y/G PVC CABLE LM 0 0 0 0 0 0 0 0

16.4.20 4x16mm2 CU/XLPE/PVC/PVC +1X16mm² Y/G PVC LM 10 0 180 0 75 0 0 0


16.4.21 4x10mm² CU/PVC/PVC+1x10mm² Y/G PVC CABLE LM 50 0 0 0 0 0 10 0
16.4.22 5x6mm² CU/PVC/PVC CABLE LM 0 0 0 0 0 0 0 0
16.4.23 3x6mm² CU/PVC/PVC CABLE LM 10 0 0 0 0 0 0 0
0 0 0 0
16.50 Isolating switches 0 0 0 0 0 0 0 0
0 0 0 0

Supply, install, test and commission Isolating switch


points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0 0 0 0
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

0 0 0 0
16.5.1 25A, SPN ,IP65 No. 14 0 4 0 13 0 5 0
16.5.2 25A, TPN ,IP65 No. 3 0 6 0 13 0 4 0
16.5.3 32A, SPN ,IP65 No. 5 0 6 0 13 0 2 0
16.5.4 32A, TPN ,IP65 No. 10 0 0 0 2 0 3 0
16.5.5 32A, SPN ,IP54 for D.W No. 1 0 2 0 1 0 0 0
16.5.6 40A, TPN ,IP65 No. 0 0 0 0 1 0 0 0
16.5.7 50A, TPN ,IP65 No. 0 0 2 0 2 0 0 0
16.5.8 63A, TPN ,IP66 No. 0 0 0 0 0 0 0 0
16.5.9 80A, TPN ,IP65 No. 0 0 0 0 0 0 0 0
16.5.10 100A, TPN ,IP65 No. 0 0 0 0 6 0 0 0
0 0 0 0
16.60 Power Socket Outlets 0 0 0 0 0 0 0 0
Sections 16020, 16120, 16130 ,16140 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 211/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, test and commission Socket outlet


pints only including all necessary PVC conduits,
wires, cables, pull and junctions boxes , floor boxes
(where needed as per drawings) ,cover plates , 0 0 0 0
ancillaries , connections, and all needed accessories
as shown on the drawings . excluding outlet device
and face plate .

0 0 0 0
Socket outlet, 13A, 1- phase, 1- gang , switched (wall or 90 0 110 0 229 0 28 0
16.6.1 No.
in floor mounted box)

16.6.2 Ditto but ceiling mounted No. 45 0 48 0 0 0 0 0

16.6.3 Ditto but water proof No. 23 0 23 0 32 0 8 0

16.6.4 Ditto but double gang(wall or in floor mounted box) No. 22 0 31 0 53 0 8 0

16.6.5 Ditto but double gang water proof No. 0 0 0 0 10 0 6 0

16.6.6 Power points for motorized shutter No. 35 0 38 0 63 0 15 0

16.6.7 Spur outlet for electrical water heater No. 13 0 18 0 27 0 6 0

16.6.9 Power points for hand & hair ddryer No. 11 0 12 0 19 0 4 0

16.6.13 Power points for Jaccuzi OR Fountains No. 1 0 0 0 0 0 0 0

20A, double pole switch with neon.


16.6.8 No. 13 0 18 0 27 0 3 0

Socket outlet, 15A, 1- phase, 1- gang , for washer or 5 0 8 0 10 0 0 0


16.6.10 No.
dryer

16.6.11 Ditto but 3-phase No. 0 0 0 0 0 0 0 0

16.6.11.1 FLOOR BOX 2P+1D No. 0 0 0 0 0 0 0 0

16.6.11.2 FLOOR BOX 1P+1TV No. 0 0 0 0 0 0 0 0

16.6.11.3 FLOOR BOX 2P+1D+1TV No. 1 0 0 0 0 0 0 0

0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 212/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
WIRING DEVICES : 0 0 0 0

INSTALL ONLY ( SUPPLY BY OTHERS) WIRING 0 0 0 0


DEVICES INCLUDES ALL ACCESSORIES , (GFCI)

0 0 0 0
Single Switched socket 13A,220v (2P+E) Grounding type 79 0 106 0 229 0 28 0
16.6.14 NO

16.6.15 Double socket 13A,220v (2P+E),Grounding type NO 20 0 29 0 63 0 8 0

Single socket 13A,220v (2P+E) GFCI,with earth leakage 0 0 0 0 0 0 0 0


16.6.16 NO
protection

celing power socket 13A ,220v for AC (2P+E) 68 0 69 0 32 0 8 0


16.6.17 NO
Grounding type

16.6.18 Single socket 20A,220v (2P+E) FOR WATER HEATER NO 13 0 18 0 27 0 6 0

16.6.19 2phase socket 20A,220v (3P+E) with neon type, NO 13 0 18 0 27 0 3 0

SUPPLY AND INSTALL WIRING DEVICES


INCLUDES ALL ACCESSORIES (GFCI) 0 0 0 0
for maid , laundary, storage rooms

SUPPLY AND INSTALL Single Switched socket 13A,220v 11 0 4 0 0 0 0 0


16.6.21 NO
(2P+E) Grounding type (legrand/MK) or eqivelant

16.6.22 Double socket 13A,220v (2P+E),Grounding type NO 2 0 2 0 0 0 0 0

wall power socket 32 A ,220v for AC (2P+E) Grounding


16.6.23 type WATHER PROOF NO 0 0 2 0 0 0 0 0

0 0 0 0
16.70 Lighting System 0 0 0 0 0 0 0 0
Sections 16010, 16120 ,16510 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 213/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, test and commission Lighting points


with all necessary conduits, conductors , cables &
wires , junction , pull boxes, connections, 0 0 0 0
accessories, fittings, and all needed accessories as
shown on the drawings.

0 0 0 0
16.7.1 Internal Lighting points with wire size 2.5 mm2 No. 332 0 12 0 65 0 138 0

16.7.2 External Lighting points with wire size 6 or 10 mm2 No. 74 0 0 0 0 0 34 0

0 0 0 0
16.80 Lighting Fixtures 0 0 0 0 0 0 0 0
Sections 16010, 16120 ,16510 0 0 0 0

install only test and commission Lighting fixtures


and switches with all necessary accessories and 0 0 0 0
termination as shown on the drawings.

0 0 0 0
16.8.1 Type F1 No. 28 0 34 0 76 0 8 0
16.8.2 Type F2 No. 22 0 0 0 0 0 99 0
16.8.3 Type F3 No. 115 0 246 0 434 0 0 0
16.8.4 Type F4 No. 19 0 26 0 52 0 11 0
16.8.5 Type F5 No. 15 0 16 0 0 0 0 0
16.8.6 Type F6 No. 27 0 20 0 24 0 0 0
16.8.7 Type F7 No. 2 0 6 0 48 0 13 0
16.8.8 Type F8 No. 44 0 41 0 43 0 0 0
16.8.9 Type F9 No. 12 0 10 0 19 0 2 0
16.8.10 Type F11 No. 16 0 28 0 21 0 3 0
16.8.11 Type F12 No. 0 0 0 0 0 0 0 0
16.8.13 Type F14 No. 0 0 0 0 14 0 0 0
16.8.14 Type F14E No. 0 0 0 0 3 0 0 0
16.8.15 Type F15 No. 1 0 0 0 8 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 214/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
16.8.16 Type F15E No. 0 0 6 0 2 0 1 0
16.8.17 Type F18 No. 2 0 2 0 0 0 0 0
16.8.18 Type F19 No. 16 0 12 0 29 0 1 0
16.8.20 Type EX1 No. 0 0 0 0 0 0 0 0
16.8.21 Type EX3 No. 0 0 0 0 12 0 16 0
16.8.22 Type EX4 No. 34 0 12 0 50 0 18 0
16.8.23 Type EX5 No. 32 0 0 0 14 0 0 0
16.8.24 Type EX6 No. 0 0 0 0 0 0 0 0
supply and install,test and commission Lighting
fixtures and lighting switches (All fixtures shall be
supplied in full coordination with client or client's
representative) including all necessary transformer
ballast, switch gear, lamps, lamp holders, diffusers,
internal wires, supports, clamps, conduits,
connections, terminations, fixings, fittings and all 0 0 0 0
needed accessories and as shown on the drawings.
for maid, laundary, storage rooms

0 0 0 0
16.8.25 Type F1 No. 4 0 2 0 0 0 0 0
16.8.26 Type F4 No. 0 0 0 0 0 0 0 0
16.8.27 Type F9 No. 0 0 8 0 0 0 0 0
16.8.29 Type F14 No. 0 0 0 0 0 0 0 0
16.8.30 Type F15 No. 6 0 5 0 0 0 0 0
16.8.31 Type F15E No. 2 0 0 0 0 0 0 0
16.8.32 Type F19 No. 0 0 4 0 0 0 0 0
0 0 0 0
16.90 Fire Alarm Installation 0 0 0 0 0 0 0 0
Sections 16710 Fire Alarm 0 0 0 0
0 0 0 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reSet button, switches,
batteries, charger, internal conductor, enclosure and all
16.9.1 0 0 0 0 0 0 0 0
other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 215/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
0 0 0 0
16.9.1.1 Fire alarm Slave panel, ref. SACP-DW (1 loop) No. 0 0 0 0 0 0 0 0
16.9.1.2 Fire alarm Slave panel, ref. SACP-G.V (1 loop) No. 0 0 0 0 0 0 0 0
16.9.1.3 Fire alarm Slave panel, ref. SACP-M.V (1 loop) No. 0 0 0 0 0 0 0 0
16.9.1.4 Fire alarm Slave panel, ref. SACP-A.V (1 loop) No. 0 0 0 0 0 0 0 0
16.9.1.5 Fire alarm Slave panel, ref. SACP-D.A/X (1 loop) No. 0 0 0 0 0 0 0 0
16.9.1.6 Fire alarm Slave panel, ref. SACP-C.H (1 loop) No. 0 0 0 0 0 0 0 0
16.9.1.7 Fire alarm Slave panel, ref. SACP-M&N (3 loops) No. 0 0 0 0 0 0 0 0
16.9.1.8 Fire alarm Slave panel, ref. SACP-DM&N (1 loop) No. 0 0 0 0 0 0 1 0
16.9.1.9 Fire alarm Slave panel, ref. SACP-A.V (1 loop) No. 1 0 0 0 0 0 0 0

16.9.1.10 Fire alarm Slave panel, ref. SACP-M.V/X (X: R, L) (1 loop) No. 0 0 2 0 0 0 0 0

16.9.1.11 Fire alarm Slave panel, ref. SACP-DI&A (1 loop) No. 0 0 0 0 0 0 0 0


16.9.1.12 Fire alarm Slave panel, ref. SACP-I.V (1 loop) No. 0 0 0 0 1 0 0 0
16.9.1.13 Fire alarm Slave panel, ref. SACP-AE.V (1 loop) No. 0 0 0 0 1 0 0 0
0 0 0 0

Addressable Fire alarm devices including covers,


fixings ,conductors, conduits, pull and junction boxes, 0 0 0 0 0 0 1 0
16.9.2
cables, wires, connections and terminations, and all
needed accessories as shown on the drawings.

0 0 0 0
16.9.2.1 Addressable smoke detector No. 29 0 36 0 14 0 1 0
16.9.2.2 Ditto but with sound base No. 23 0 28 0 77 0 7 0
16.9.2.3 Addressable heat detector No. 4 0 4 0 5 0 0 0
16.9.2.4 Ditto but with sound base No. 0 0 0 0 5 0 0 0
16.9.2.5 Break glass station No. 5 0 12 0 2 0 1 0
16.9.2.6 Audible/visual warning devices indoor No. 2 0 2 0 5 0 1 0
16.9.2.7 Audible/visual warning devices outdoor No. 4 0 4 0 4 0 1 0
0 0 0 0
16.10 EARTHING SYSTEM 0 0 0 0 0 0 0 0
Sections 16125 EARTHING 0 0 0 0
0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 216/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,8 earthing pits, various
corner earthing points of the building , connected with
16.10.1 ls 1 0 1 0 1 0 1 0
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0 0 1 0 1 0
16.10.2 ls
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0 0 0 0
16.11 CCTV SYSTEM 0 0 0 0 0 0 0 0
0 0 0 0

Sections 16690 IP network components,16690 , 0 0 0 0


16738,16739

supply and Install only indoor cameras's points including


all necessary empty PVC conduits from data cabinet to 3 0 8 0 12 0 1 0
16.11.4 point's location , pull junction boxes, and all needed
accessories as per drawings.

0 0 0 0
16.12 LOW CURRENT SYSTEMS 0 0 0 0 0 0 0 0

Sections 16110, 16120, 16130, 16140, 16690 0 0 0 0


IP network

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 217/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount
components,16700 ,16738,16739 0 0 0 0

Voice & Data Distribution System

Supply and install of voice & data distribution Equipment,


including but not limited to connections, supports , patch
panel , distributer switches , ends of cables ,data rack 9u
cabenit and all necessary accessories; all in accordance
with the Drawings and Specifications and as approved by
16.12.1.1 owner .  set 0 0 0 0
A) the main
distributor (SWITCH to connect devices not less than
1000 MB .
B) Distributor SWITCH devices to
wall outlet not less than 100 MB (By Others )

0 0 0 0

Supply, install, test and commission voice & data


distribution circuit points , including all ,
fixings ,wires, cat6 A ,cable terminals, cable trunks
and trays ,conduits, pull and junction boxes, floor 0 0 0 0
suuports (where needed as per drawings) ,cover
plates , connections from data rack to the outlet, and
all needed accessories as shown on the drawings.
excluding outlet device and face plate .

0 0 0 0

16.12.1 RJ45 socket outlet wall No. 22 0 42 0 56 0 5 0

16.12.2 Access point installed above false ceiling No. 6 0 4 0 16 0 2 0

16.12.3 RJ45 Data socket outlet , installed in floor mounted box No. 1 0 0 0 0 0 0 0

16.12.4 RJ45 access point installed above faL.Se ceiling No. 6 0 4 0 16 0 2 0

RJ45 socket outlet used for IP- camera (only for 0 0 0 0 4 0 1 0


16.12.5 No.
outdoor type and for indoor at main diwaniah & gust villa)

0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 218/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply and installation of reception satellite system


including reception and rules dishes , receivers,
amplifiers , LNP, links, boxes and dividers with 1 0 2 0 2 0 1 0
16.12.5.1 LS
adjustment, calibration, operation and delivery ,
programming of required stations and all in
accordance with the details shown on drawings

0 0 0 0

supply and install installation and test Mural TV socket


outlet includes boxes, coaxial cables , pipes , conduits 13 0 12 0 35 0 3 0
16.12.5.2 No.
and all needed accessories , excluding outlet device and
face plate .

0 0 0 0

Supply, install, test and commission Inter come system


includs indoor unit , out door unit , 2P cables and 1 0 2 0 2 0 0 0
16.14 LS
connections , PVC conduits , power supply , and all
needed accessories and as shown on the drawings .

0 0 0 0

Elevators & Dumbwaiter electrical work related 0 0 0 0 0 0 0 0


16.16 only )

0 0 0 0

install, test and commission an electrical feeding points


16.16.1 for electrical elevators , with all necessary equipment No. 1 0 2 0 2 0 0 0
(for specification refer to CONVEYING SYSTEM div 14.1)

0 0 0 0

16.16.2 Ditto but for dumbwaiter No. 1 0 2 0 2 0 0 0

0 0 0 0

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 219/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

Supply, install, test and commission (6W) Ceiling metallic


16.17 loudspeaker (Recessed) complete with wires , and all No. 0 0 0 0 0 0 0 0
needed accessories as shown on the drawings.

0 0 0 0

Supply, install, test and commission (10W) Ceiling


16.18 metallic loudspeaker wall mounted complete with wires , No. 0 0 0 0 0 0 0 0
and all needed accessories as shown on the drawings

0 0 0 0
16.19 Ditto but weather proof No. 0 0 0 0 0 0 0 0
0 0 0 0

Supply, install, test and commission Music Rack located


at control room at roof complete with wires, conduits ,
Amplifiers , power supply , back up batteries, AM/FM
digital tuner , DVD player, MP3 player , CD player , 0 0 0 0 0 0 0 0
16.20. LS
CasSette player , Portable UHF- Band Wireless
microphone (complet with receiver and transmitter) ,
microphone , and all needed accessories as shown on the
drawings

0 0 0 0
0 0 0 0

DIV#16 Total cost of this section Carried Forward To Summary 0 0 0 0

*** NOTE:-

Item overlooked in the bill of quantity but shown


in drawings, specification and schedules
necessary for the satisfactory completion of the
works may be priced hereunder.

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary - - - -

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 220/2284


ALL DISCIPLINES DIVISION # 1~16 / ALL DISCIP

IBRAHIM & ABD DIWANIAH IBRAHIM


ADEL VILLA MOHAMMED VILLA ILLAH VILLA & ABD ILLAH

ITEM DIV B09 B10 B11 B12


DESCRIPTION UNIT
# # Qty. Amount Qty. Amount Qty. Amount Qty. Amount

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 221/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

1.10 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.10 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2.00 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

2.30 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2

2.40 ANTI TERMITE


Refer to spesification # 2285

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 222/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
2.4.1 Termite control treatment for all vertical and L.S
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3.00 DIV#3 CONCRETE WORKS

Plain concrete (grade 15), 15N/mm2 at 28 days cylinder


compressive strength, using portland cement, including all
3.10 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3

3.1.2 Blinding, 50mm thick under slabs on grade m3

3.1.4 Blinding, 50mm thick under all types of tie beams m3

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.20 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 223/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

3.2.1.1 Foundations; (Raft , continous )

3.2.2 Tie beams - Intermediate m3

3.2.3 Upper tie beams m3

3.2.4 Slabs on grade m3

3.2.5 Walls below slab on grade m3

3.2.6 Columns Below slab on grade m3

3.2.7 Water Tanks Slabs and Walls m3

3.2.8 Swimming pool Slabs and Walls m3

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.30 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3

3.3.2 Shear Walls , free standing walls above slab on Grade m3

3.3.3 Suspended solid slabs; including drop beams m3

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2

3.3.5 Stairs (steps, flights and landing) m3

3.3.6 Beams m3

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 224/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
3.40 CONCRETE PROTECTION AND INSULATION

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2
Supply, install and test of the liquid applied polyurethane
waterproofing; applied in two layers; 1.5 liters/m 2

3.4.1 To all structural elements below grade m2

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2


3.4.2.1 Below slab on grade for basements -Horizontal
3.4.2.2 Water Tanks
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr

DIV#3 Total cost of this section Carried Forward To Summary

4.00 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and


internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 225/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.10 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.20 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2


internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.30 Forming of Arch. Shape

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 226/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5.10 DIV#5 METAL WORKS LS


NA

DIV#5 Total cost of this section Carried Forward To Summary

6.10 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7.10 DIV#7 THERMAL & MOISTURE

7.10 Waterproofing

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 227/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2


moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

7.1.3 Supply, install and test of the liquid applied m2


polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 228/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 229/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8.10 DIV#8 DOORS & WINDOWS

Supply and installation of complete doors &


windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.10 Basement Floor


Excluded- At this stage

8.20 Ground Floor


Excluded- At this stage

8.50 First Floor


Excluded- At this stage

8.60 Penthouses
Excluded- At this stage

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 230/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

DIV#8 ALUMINUM & GLAZING INCLUDING WINDOWS SHUTTERS


(separate price from main windows units)

Supply and installation of electric motor operated windows


roller shutters (unless otherwise noted), complete with all its
necessary accessories to complete ready to operate facility
with as specified in the drawings and windows schedule, as
follows:

8.70 Windows Type / Main Dewaniah B-01:


Excluded- At this stage

8.80 Windows Type / Guest Villa B-02:


Excluded- At this stage

8.90 Windows Type / Mother Villa B-03:


Excluded- At this stage

8.10 Windows Type / Abdulaziz Villa B-04:


Excluded- At this stage

8.11 Windows Type / Abdulaziz Douplex B-05:


Excluded- At this stage

8.12 Windows Type / Club House B-06:


Excluded- At this stage
8.13 Windows Type / Majid & Nasir Villa B-07:
Excluded- At this stage

8.14 Windows Type / Majid & Nasir Diwaniah B-08:


Excluded- At this stage

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 231/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
8.15 Windows Type / Adel Villa B-09:
Excluded- At this stage

8.16 Windows Type / Mohammed Villa B-10:


Excluded- At this stage

8.17 Windows Type / Abdulillah & Ibrahim Villa B-11:


Excluded- At this stage

8.18 Windows Type / Diewaniah Ibrahim B-12:


Excluded- At this stage

DIV#8 Total cost of this section Carried Forward To Summary

9.10 DIV#9 FINISHES

Plastering Works

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 232/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
9.1.2 Plastering to walls internal sides. m2

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2


(Painted spaces only)

9.20 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2


R.C slab. (color as to be approved by the client
or client site representative) To store and stairs .

9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2

9.2.12 Moisture resistant gypsum board with paint for wet area m2

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Outside the building


Excluded- At this stage
9.2.15 EF09 WOOD TRELLIS

Wall Finishes

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 233/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Excluded- At this stage

9.30 External Walls Surfaces


Excluded- At this stage

GRC Panels
Excluded- At this stage

9.40 Internal Walls Surfaces

9.4.1 Paint the interior walls m2

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2


only for Maids bathrooms

9.50 Glass Walls


Excluded- At this stage

9.60 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-
Only for Maids , stores
9.6.1 VITRIFIED PORCELAIN TILES (300*300*8)mm m2

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2


(300*300*8)mm

9.6.16 100 mm Concrete with epoxy paint layer m2

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 234/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

9.70 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include
grooves for non-slip material and nose forming as
follows:

9.7.1 for Service Staircase L.M

9.7.19 Main Entrance


Excluded- At this stage

DIV#9 Total cost of this section Carried Forward To Summary

10.10 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is
incoporated in related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage

10.20 Toilet Accessories


Excluded- At this stage

10.30 MISCELLANEOUS

Stair & The Balconies and Windows Handrail

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 235/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

External Balconies
Excluded- At this stage

Internal Stair

10.3.3 Handrail to external stairs


Excluded- At this stage
10.3.4 Handrail to internal stairs LM
for service stair cases

Ladder

10.3.5 Internal metal ladder Radius 1 meter and 0.93 width

to connect between laundry /iron and maids lobby


complete with paint finish

10.3.6 PVC COATED STEEL LADDER RUNGS for water tanks No.
To suit water tank - HIGHT 3.3 : 3.72

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks - stone excluded on;y cover

Master Key System


Excluded- At this stage

DIV#10 Total cost of this section Carried Forward To Summary

11.10 DIV#11 EQUIPMENTS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 236/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
NA

DIV#11 Total cost of this section Carried Forward To Summary

12.10 DIV#12 FURNITURE


NA

DIV#12 Total cost of this section Carried Forward To Summary

13.10 DIV#13 SPECIAL CONSTRUCTIONS

13.10 Sky Light


Excluded- At this stage

13.20 Fountains Works


Excluded- At this stage

13.30 SWIMMING POOL FINISH


Excluded- At this stage

13.40 SAFETY HANDRAIL PANELS


Excluded- At this stage

DIV#13 Total cost of this section Carried Forward To Summary

14.10 DIV#14 CONVEYING SYSTEM

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 237/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

14.10 LIFT / Private House & Dumpwaiter


Excluded- At this stage

DIV#14 Total cost of this section Carried Forward To Summary

15.10 DIV#15 DIVISION 15 - MECHANICAL

15.10 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM

15.1.1.2 25 mm outside diameter pipe LM

15.1.1.3 32 mm outside diameter pipe LM

15.1.1.4 40 mm outside diameter pipe LM

15.1.1.5 50 mm outside diameter pipe LM

15.1.1.7 80 mm outside diameter pipe LM

Isolation Valves

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 238/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm no
15.1.1.15 Gate vlave Ø 32 mm no
15.1.1.16 Gate vlave Ø 40 mm no
15.1.1.17 Gate vlave Ø 50 mm no
15.1.1.18 Gate vlave Ø 90 mm no

Concealed Valve
15.1.1.19 Concealed valve Ø 25 mm no
15.1.1.20 Concealed valve Ø 32 mm no
15.1.1.21 Concealed valve Ø 40 mm no

15.1.2 Electric Water Heaters

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings ."by Saudi
Ceramic or equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No.

15.1.2.3 EWH-3 (80 Liter ) No.

15.1.2.4 EWH-4 (100 Liter) No.

15.1.3 Domestic Cold water tank

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 239/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No.

15.1.4 Ground Water Tank Accessories

Level control float switches with electric connections,


15.1.4.4 complete with but not limited to over flow alarm bell LM
and all necessary works

Bronze equilibrium ball float valve, installed connected


15.1.4.5 and tested complete with accessories as specified as LM
shown on drawings.

15.1.4.6 Vent. 65 mm diameter. No.

15.1.5 Pumps

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on
drawings."Grundfos ,KSB , Aurora or equivalent as per
owner instructions"

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set

15.1.6 Domestic Water Booster Set

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 240/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating valves PN 16, lug and , strainer PN
16, flexible connections, concrete inertia pad, house
pad, vibration eliminator pad, low level control float
switches, pressure switch dry run protection and
controls all supplied from pump manufacturer
diaphragm tank (s), food quality synthetic rubber
membrane, steel painted body, working pressure 10
bars with isolating valve and pressure gauge, electric
connections, wiring and accessories all as specified and
shown on the drawings. "Grundfos ,KSB , Aurora or
equivalent as per owner instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set

15.1.6.2 BP-2 (35 GPM /43 FT) Set

15.1.6.3 BP-3 (55 GPM /43 ft) Set

15.20 FIRE FIGHTING SYSTEM


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 241/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No.

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No.

15.30 PLUMBING FIXTURE APPLIANCES

supplying, installing, connecting and testing vitreous


china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains
including adapters, branches, tees, valves, supports
from galvanized steel, brackets, hangers ,shelves,
siphon, terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet

Western type vitreous china water cloSet complete


with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified.

WC-01 ( Supply and install ) for Maids rooms (ideal


15.3.1.1 No.
standard or equivlant)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 242/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
install only ,connection and testing wall mounted WC
complete with but not limited to concealed
tank with actuator flush panel or pneumatic
push button for washdown wall-hung toilets and
Chrome hand spry Include adjustable wall bracket with
min. 1.2 m hose
System shall fit within minimum 51
⁄2" (146 mm) framing wall or plumbing chase, with
steel framing members Framing members
should be capable of supporting 400 kg load without
damage to the wall. Water
supply shall have minimum flow
pressure of 2 PSI (0.01 MPa). The toilet bowl
shall be a third party listed low-consumption
1.6/0.8 GPF (6/3 LPF) dualflush
2-hole wall-hung type. The carrier frame
shall be adjustable for bowl rim heights from
15" to 19" (381 to 483 mm). Actuator flush
panels shall be diecast zinc, molded plastic or
fabricated stainless steel and plated to
preserve material integrity. All components
shall be compliant with applicable codes and
product standards.

WC-02 Install Only ( Fixtures Purchase by Client -Part


15.3.1.2 No.
of ID )

Lavatories
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer and 800x900mm wall
mirror with chamfered edge including all the necessary
fittings & accessories and approved by the owner .

( Lav-01 ) ( Supply and install for Maids rooms ( ideal


15.3.2.1 standard inclusive of water mixer grohe or equivlant ) No.

Supply ,install ,connection and testing for recessed


mounted Lavatories complete including wash basin
mixer with but not limited to hangers support
(galvanized steel made)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 243/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.3.2.2 ( Lav-02 ) Install Only ( Fixtures Purchase by Client No.


-Part of ID )

Bathtub
Supply and install bathtub ,complete, including water
feed, waste and vent branch piping works to mains
including adapters, branches, tees, valves, mixer,
supports, brackets, hangers , siphon ..etc. all as
specifications, drawings and water consumption
rationalization specifications all model must approved
from owner representative and consultant. only as
required for fixture installation and to wall connection .
BT-02 Install ony ( Fixture Purchase by Client -Part of
15.3.3.2 No.
ID )

kitchen sink
Excluded- At this stage

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (as per owner
representative and consultant.)

15.3.9.1 SH-01 (sypply and install) grohe Type or equivalent . No.

15.3.9.2 SH-02 Install Only ( Fixtures Purchase by Client -Part of No.


ID )

15.40 STORMWATER AND DRAINAGE SYSTEM

15.4.1 Pipework

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 244/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM

15.4.1.2 80 mm diameter pipe LM

15.4.1.3 110 mm diameter pipe LM

15.4.1.4 160 mm diameter pipe LM

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No.

Floor Cleanout

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 245/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No.

15.4.1.8 WCO- 110mm No.

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No.


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and No.
as shown on drawings .

Gully trap
Constructing , connecting and testing Gully trap
complete with heavy duty cast iron cover and all other
accessories all as specifications and as shown on
15.4.1.9.2 No.
drawings

Submersible Pumps

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 246/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-01 (35 GPM / 18 FT )
15.4.1.10 set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No.

15.4.1.16 RD, 75mm outlet diameter No.

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter

Roof Vent Cap

Supply Roof vent and cap, UPVC body, installed,


connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"

15.4.1.19 Type RVC, 110 mm diameter pipe No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 247/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.50 HVAC SYSTEM


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 248/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, test and commission Packaged roof
mounted air-condition unit, (HEAT PUMP TYPE)
according to the following specifications : Heavy gauge
galv. Steel sheet, with electrostatic powder paint of
epoxy coating finish. Double skin unit casing with
suitable thermal insulation, Weather proof, Hermetic
sealed scroll compressors Refrigerant , Micro processor
controller, Return fan and supply fan, Aluminum Flat
Filter, Economizer section, Mixing box with
automatically operated fresh air damper, External
overload protections for all compressors and circuit
breaker for the unit. Evaporator coil and condenser coil
15.5.3.1 made of copper tubes and aluminum fins, Thermal
expansion valve, Gas control, Filter driers, Sight glass,
Solenoid valves; High and low pressure cutouts; Oil
pressure switches; Air and fire dampers. Drain system
for condensate water Anti vibration pads; Concrete
bases; Inside air temperature controlling according to
ASHRAE standards and All electrical wiring and
conduits required, Kinetic Float Base, Equipment
capacities as tabulated on the drawings. By Daikin
manuf. or equivelant

15.5.3.1.4 PAC-04 6TR No.

15.5.3.1.5 PAC-05 7.5TR No.

15.5.3.1.6 PAC-06 8.5TR No.

15.5.3.1.7 PAC-07 - 10TR No.

15.5.3.1.9 PAC-09 - 15TR No.

15.5.3.1.10 PAC-10 24TR No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 249/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
power connections between the isolator switch and the
15.5.3.2 outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Concealed Type - for Vills

15.5.3.2.1.1 FCU-01 - 1.5TR

15.5.3.2.1.2 FCU-02 - 2TR

15.5.3.2.1.3 FCU-03 - 2.5TR

15.5.3.2.1.4 FCU-04 - 3TR

15.5.3.2.1.5 FCU-05 - 3.5TR

15.5.3.2.1.6 FCU-06 - 4TR

15.5.3.2.1.8 FCU-08 - 5TR

Cassette units - for Kitchens

15.5.3.2.1.9 CDX-01 -1.5TR

15.5.3.2.1.10 CDX-02 - 2TR

15.5.3.2.1.11 CDx-03 -2.5TR

Split Wall mounted Type - For service Drivers ,


Maid stores ..

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 250/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
15.5.3.2.1.12 WDX-01 -1TR

15.5.3.2.1.13 WDX-02 -1.5TR

15.5.3.3 Refrigeration Unit Type

Supply, install, test and commission refrigeration unit


type with appropriate compressors, evaporators,
refrigeration gas and all components and accessories.

15.5.3.3.1 Ref. ROU-01 / RIU-01 -Ref. ROU-B02-1 / RIU-B02-1 No.

15.5.3.3.2 Ref. ROU-02 / RIU-02 -Ref. ROU-B02-2 / RIU-B02-2 No.

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL

Supply, install, test and commission centrifugal in line/


roof mounted (Roof Top Type) belt drive exhaust fan
with external motor installation for kitchen hoods, fans
shall be able to operate for no less than one hour at
high temperature , complete with steel bases, steel
box, frames, rubber pads, sealers for leakage, access
panels , flexible connections with ducts, guard screens,
back draft damper with all fixing, support, grease
drain , and all required accessories and all required
accessories for proper installation and as per specs &
dwgs. "suadi fans , greenheck, ASEM or equivalent as
per owner instructions"

15.5.4.1 HEF-B01-G-01 No.

15.5.4.2 HEF-B02-B-01 No.

15.5.4.4 HEF-B02-B-02 No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 251/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.5.4.4.1 HEF-B02-B-03

15.5.4.5 HEF-B03-B-01

15.5.4.6 HEF-B03-G-01 No.

15.5.4.7 HEF-B03-FR-01 No.

15.5.4.8 HEF-B04-B-01 No.

15.5.4.9 HEF-B04-G-01 No.

15.5.4.10 HEF-B04-G-02 No.

15.5.4.11 HEF-B07-B-01 No.

15.5.4.12 HEF-B07-B-02 No.

15.5.4.13 HEF-B07-B-03 No.

15.5.4.14 HEF-B09-B-01 No.

15.5.4.14.1 HEF-B10-B-01 No.

15.5.4.14.2 HEF-B10-B-02 No.

15.5.4.15 HEF-B11-B-01 No.

15.5.4.16 HEF-B11-B-02 No.

15.5.4.17 HEF-B11-B-03 No.

15.5.4.18 HEF-B11-B-04 No.

15.5.4.19 HEF-B11-B-05 No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 252/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

Fan Section (belt driven)

15.5.4.20 MAF-B02-B-01 No.

15.5.4.21 MAF-B02-B-02 No.

15.5.4.22 MAF-B07-B-01 No.

15.5.4.23 MAF-B07-B-02 No.

15.5.4.24 MAF-B07-B-03 No.

15.5.4.25 MAF-B11-B-01 No.

15.5.4.26 MAF-B11-B-02 No.

15.5.4.27 FAF-B01-01 No.

15.5.4.30 FAF-B03-01 No.

15.5.4.31 FAF-B04-01 No.

15.5.4.32 FAF-B05-01 No.

15.5.4.33 FAF-B05-02 No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 253/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.5.4.34 FAF-B07-B-01 No.

15.5.4.35 FAF-B07-01 No.

15.5.4.36 FAF-B07-02 No.

15.5.4.37 FAF-B08-01 No.

15.5.4.38 FAF-B09-01 No.

15.5.4.39 FAF-B10-01 No.

15.5.4.40 FAF-B10-02 No.

15.5.4.41 FAF-B11-01 No.

15.5.4.42 FAF-B11-02 No.

15.5.4.43 FAF-B12-G-01 No.

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.45 EXF-B01-B-02 ( Roof top ) No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 254/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.5.4.46 EXF-B01-B-03( Roof top ) No.

15.5.4.47 EXF-B01-G-01( Roof top ) No.

15.5.4.48 EXF-B01-G-02( Roof top ) No.

15.5.4.52 EXF-B02-B-01( Roof top ) No.

15.5.4.53 EXF-B02-B-02( Roof top ) No.

15.5.4.54 EXF-B02-B-03( IN LINE ) No.

15.5.4.55 Ditto but Centrifugal in line fan

15.5.4.56 EXF-B02-G-02( IN LINE ) No.

15.5.4.57 EXF-B02-G-03( IN LINE ) No.

15.5.4.58 EXF-B02-G-04( IN LINE ) No.

15.5.4.59 EXF-B02-G-05( IN LINE ) No.

15.5.4.60 EXF-B02-G-06( IN LINE ) No.

15.5.4.61 EXF-B02-G-07( IN LINE ) No.

15.5.4.62 EXF-B06-B-01 No.

15.5.4.63 EXF-B06-G-01 No.

15.5.4.64 EXF-B06-G-02 No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 255/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.5.4.65 EXF-B06-G-03 No.

15.5.4.66 EXF-B06-G-04 No.

15.5.4.67 EXF-B07-B-01 No.

15.5.4.68 EXF-B07-B-02 No.

15.5.4.69 EXF-B07-B-03 No.

15.5.4.70 EXF-B07-B-04 No.

15.5.4.71 EXF-B07-B-05 No.

15.5.4.72 EXF-B07-F-01 No.

15.5.4.73 EXF-PAC-B07-01(INLINE) No.

15.5.4.75 EXF-B08-G-01(INLINE) No.

15.5.4.76 EXF-PAC-B08-01(INLINE) No.

15.5.4.77 EXF-PAC-B08-02(INLINE) No.

15.5.4.78 EXF-PAC-B08-03(INLINE) No.

15.5.4.82 EXF-PAC-B11-01(INLINE) No.

15.5.4.83 EXF-B12-G-01 No.

15.5.4.84 EXF-B12-G-02 No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 256/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
15.5.4.85 EXF-PAC-B12-01 No.

15.5.4.86 EXF-PAC-B12-02 No.

15.5.4.90.1 AEX-B02-01 NO
15.5.4.90.2 AEX-B04-02

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No.


15.5.4.92 CEX-02 No.

Supply, install test & commission air curtain all


required accessories as per specs and schedule .

15.5.4.93 AC-01 No.


15.5.4.94 AC-02 No.

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.95 WEX-B02-01 NO

15.5.4.96 WEX-B03-01 NO

15.5.4.97 WEX-B04-01 NO

15.5.4.98 WEX-B06-01

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 257/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.5.5 Condensate Pipework

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM

15.5.5.4 50mm outside diameter pipe LM

15.5.6 Ductwork

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 258/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No.
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No.
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply ,install ,connect ,test and commission


protection, aluminum cladding for external duct,
15.5.6.4 kg
complete with but not limited to all acessories , flow
indicators, labels, color code stickers,….etc

15.5.7 Ductwork Insulation

Supply, install, connect, test and commission


Fiberglass blanket duct insulation for supply, fresh air
and return ductwork, Fiberglass insulation 25mm thick
density 24kg/m3, factory laminated to a reinforced foil
15.5.7.1 Kraft vapour barrier facing covered with canvas fabric m2
wrap and two layers of fungus resistant mastic,
installed connected and tested complete including self
adhesive fixing pins, sealing tape, wire banding and
accessories all as specified and shown on drawings.

15.5.7.2 Ditto but with thikness 50 mm and 48 kg/m³ desity m2

15.5.8 Duct Acoustic Inner Liner

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 259/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, connect, test and commission Duct


acoustic inner liner Rubber insulation thickness 13 mm
fixed with fire resistant adhesive and mechanical
15.5.8.1 LS
fasteners, installed, connected and tested complete
with accessories, to meet NC as specified and shown
on drawings.

15.5.9 Air Diffusers, Registers, and Grilles

Supply, install, connect, test and commission, Supply


Linear Slotting Diffuser as per drawings, complete with
volume dampers, insulated plenum box and including
all accessories to complete the work.. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.1 SLD - 1 LM

15.5.9.2 SLD - 2 LM

15.5.9.3 SLD - 3 LM

15.5.9.4 SLD - 4 LM

15.5.9.5 SLD - 5 LM

15.5.9.6 SLD - 6 LM

15.5.9.7 SLD - 7 LM

15.5.9.8 SLD - 8 LM

Supply, install, connect, test and commission,Return


and installation of return Linear Slotting Diffuser as per
drawings, complete with volume dampers, insulated
plenum box and including all accessories to complete
the work.

15.5.9.9 RLD - 1 LM

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 260/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
15.5.9.10 RLD - 2 LM

15.5.9.11 RLD - 3 LM

15.5.9.12 RLD - 4 LM

15.5.9.13 RLD - 5 LM

15.5.9.14 RLD - 6 LM

15.5.9.15 RLD - 7 LM

15.5.9.16 RLD - 8 LM

Supply, install, connect, test and commission, powder


coated aluminum register air grill with opposed blade
dampers , color to be selected by the Engineer,
including connections to ductwork with plenum box
and flexible duct, volume damper for balancing
purposes, mounting, fixings and all required
accessories as per specs and drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.17 SR-01 No.

Diito as above But Return Rabeea, GGC, Beta, or


equivalent as per owner instructions"
15.5.9.18 RR-01 No.

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No.

15.5.9.20 EG-02 No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 261/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.46 EAL-B02-02 No.

15.5.9.48 EAL-B02-04 No.

15.5.9.52 EAL-B06-01 No.

15.5.9.53 EAL-B06-02 No.

15.5.9.54 EAL-B06-03 No.

15.5.9.55 EAL-B07-01 No.

15.5.9.58 EAL-B07-04 No.

15.5.9.59 EAL-B07-05 No.

15.5.9.60 EAL-B08-01 No.

15.5.9.61 EAL-B08-02 No.

15.5.9.63 EAL-B11-01 No.

15.5.9.64 EAL-B11-02 No.

15.5.9.65 EAL-B11-03 No.

15.5.9.66 EAL-B11-04 No.

15.5.9.67 EAL-B12-02 No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 262/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.60 LPG SYSTEM

15.6.1 Pipework

Supply, install test & commission, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions" Schedule 40 - inside buildings

only for diwanyah and Guest villa


15.6.1.1 25 mm diameter pipe LM

15.6.1.2 32 mm diameter pipe LM

15.6.1.3 40 mm diameter pipe LM

Supply, install & test PVC coated Copper pipes for gas
system, complete with fittings & all related works
(valves at termination points to be included in the
rate).APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"
15.6.1.4 20 mm diameter pipe LM

15.6.2 Gas Valves

Supply Isolating ball valves, quarter-turn, installed,


connected, and tested complete including all
accessories, all as specified and shown on drawings.
15.6.2.1 20 mm diameter No.

15.6.3 Solenoid Gas Valves

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 263/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply Solenoid gas valves, installed, connected, and
tested, complete including all accessories as specified
and shown on drawings.

15.6.3.1 40 mm diameter No.

15.6.4 Gas Regulators

Gas regulators, installed, connected, and tested


complete with isolating valve, including all accessories
as specified and shown on drawings.

15.6.4.1 32 mm diameter No.

15.6.6 Gas Manifold

Supply Gas manifold, installed, tested, complete with


steel cabinets, branch gas valves and accessories, all
as specified and shown on drawings.

15.6.6.1 Gas Manifold No.

SWIMMING POOL SYSTEM AND FOUNTAINS


15.70

15.7.1 PVC Pipes

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 264/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.5 63 mm LM

15.7.1.6 75 mm LM

15.7.1.7 110 mm LM

15.7.1.8 160mm LM

15.7.2 Swimming pool pump

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

15.7.2.4 FP-B07-1 No.

15.7.2.5 FP-B11-1 No.

15.7.2.6 FP-B12-1 No.

15.7.3 Inlet Fitting

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 265/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.7.3.3 Pool inlet fitting IF, 63mm diameter No.


15.7.4 Vacuum Fitting

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No.

15.7.5 Main Drain

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No.

15.7.6 Overflow Trench Fitting

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM

15.7.7 Outlet Fitting

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 266/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.7.8 Fill Fitting

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No.

15.7.9 Pool Sand Filter

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

15.7.9.1 SF-B07-1 No.

15.7.9.2 SF-B11-1 Set.

15.7.9.3 SF-B12-1 Set.

15.7.10 Chemical Feeding and Control Accessories

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No.

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 267/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

15.7.10.3 Chemical test kit No.

15.7.11 Balance Tank

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (4) m3
15.7.11.1.1 BT-B07-1 No.
15.7.11.1.2 BT-B11-1 No.
15.7.11.1.3 BT-B12-1 No.

15.7.12 Electrical Heat Exchanger

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No.

15.7.12.2 P- HE-02 (30 KW) No.

DIV#15 Total cost of this section Carried Forward To Summary

16.10 DIV#16 ELECTRICAL WORKS

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 268/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.1.1 Ref. SMDB-DW No.


16.1.2 Ref. SMDB-G.V No.
16.1.3 Ref. ESMDB-G.V No.
16.1.4 Ref. SMDB-M.V No.
16.1.5 Ref. SMDB-A.V No.
16.1.6 Ref. SMDB-D.A/X (X: R/1, L/1, R/2, L/2) No.
16.1.7 Ref. SMDB-C.H No.
16.1.8 Ref. ESMDB-C.H No.
16.1.9 Ref. SMDB-MA No.
16.1.10 Ref. ESMDB-MA No.
16.1.11 Ref. SMDB-NA No.
16.1.12 Ref. SMDB-DM&N No.
16.1.13 Ref. SMDB-A'A.V No.
16.1.14 Ref. SMDB-M.V/X (X: R, L) No.
16.1.15 Ref. SMDB-DI&A No.
16.1.16 Ref. SMDB-I No.
16.1.17 Ref. SMDB-AE No.

16.20 Motor Control Center


Section 16443

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 269/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.2.1 Ref. MCC-R No.


16.2.1.1 Ref. MCC-R/I No.
16.2.2 Ref. EMCC-R No.
16.2.3 Ref. MCC-R/X (X: R/1, L/1, R/2, L/2) No.
16.2.4 Ref. MCC-R1/M No.
16.2.5 Ref. MCC-R2/M No.
16.2.6 Ref. MCC-P/M No.
16.2.7 Ref. MCC-R1/N No.
16.2.8 Ref. MCC-R2/N No.
16.2.9 Ref. MCC-P/N No.
16.2.10 Ref. MCC-R/X (X: R, L) No.

16.30 Distribution Boards


16.3.1 Ref. DB-B No.
16.3.2 Ref. DB-G No.
16.3.3 Ref. DB-F No.
16.3.3.1 Ref. DB-F/AE
16.3.4 Ref. DB-R No.
16.3.4.1 Ref. DB-R/AE
16.3.5 Ref. EDB-G/I No.
16.3.5.1 Ref. EDB-G/AE
16.3.6 Ref. EDB-F No.
16.3.8 Ref. DP-B/I No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 270/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
16.3.8.1 Ref. DP-B/AE No.
16.3.9 Ref. DL-B No.
16.3.10 Ref. EDB-B No.
16.3.10.1 Ref. DB-G-DI&A
16.3.11 Ref. EDB-K No.
16.3.12 Ref. DP-G No.
16.3.13 Ref. DL-G No.
16.3.14 Ref. EDB-G No.
16.3.15 Ref. DP-F No.
16.3.16 Ref. DL-F No.
16.3.17 Ref. DB-B/X (X: R/1, L/1, R/2, L/2) No.
16.3.18 Ref. DB-G/X (X: R/1, L/1, R/2, L/2) No.
16.3.19 Ref. DB-F/X (X: R/1, L/1, R/2, L/2) No.
16.3.23 Ref. DB-R/X (X: R/1, L/1, R/2, L/2) No.
16.3.24 Ref. DB-GR No.
16.3.25 Ref. DB-GL No.
16.3.26 Ref. DB-EX No.
16.3.27 Ref. DB-SM No.
16.3.28 Ref. EDB-S No.
16.3.29 Ref. DB-GM No.
16.3.30 Ref. EDB-GM No.
16.3.31 Ref. DB-FM No.
16.3.32 Ref. DB-RM No.
16.3.33 Ref. DB-KM No.
16.3.34 Ref. EDB-KM No.
16.3.35 Ref. DB-SP No.
16.3.36 Ref. DB-SL No.
16.3.37 Ref. DB-KN No.
16.3.38 Ref. EDB-KN No.
16.3.39 Ref. DB-GN No.
16.3.40 Ref. DB-FN No.
16.3.41 Ref. DB-RN No.
16.3.42 Ref. EDB-GN No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 271/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
16.3.43 Ref. DB-B/S No.
16.3.44 Ref. EDB-S No.
16.3.45 Ref.DB-DM&N No.
16.3.46 Ref.EDB-DM&N No.
16.3.47 Ref. DB-B/X (X: R, L) No.
16.3.48 Ref. DB-G/X (X: R, L) No.
16.3.49 Ref. DB-F/X (X: R, L) No.
16.3.50 Ref. EDB-B/X (X: R, L) No.
16.3.51 Ref. DB-K/X (X: R, L) No.
16.3.52 Ref. DB-R/X (X: R, L) No.

16.40 Feeders
Section 16122

Feeders, conductors and cables including all necessary


supports, brackets, pipes, cable trayes (where needed) ,
conduits, manholes (if needed), luges, glands, cable
terminaL.S , terminations and electrical connections and
all needed accessories as shown on the drawings.

16.4.1 2(4x240) mm2 CU/XLPE/SWA/PVC LM


16.4.4 4x300mm² CU/XLPE/SWA/PVC LM
16.4.5 4x240 mm2 CU/XLPE/SWA/PVC LM
16.4.6 4x185 mm2 CU/XLPE/SWA/PVC LM
16.4.7 4x150 mm2 CU/XLPE/SWA/PVC LM
16.4.8 4x120 mm2 CU/XLPE/SWA/PVC LM
16.4.9 4x70 mm2 CU/XLPE/SWA/PVC LM
16.4.10 4x240mm² CU/XLPE/PVC + 1x120mm² Y/G PVC CABLE LM
16.4.11 4x150mm² CU/XLPE/PVC + 1x70mm² Y/G PVC CABLE LM
16.4.12 4x120mm² CU/XLPE/PVC + 1x70mm² Y/G PVC CABLE LM
16.4.13 4x95mm² CU/XLPE/PVC + 1x50mm² Y/G PVC CABLE LM
16.4.14 4x70mm² CU/XLPE/PVC + 1x35mm² Y/G PVC CABLE LM
16.4.15 4x50mm² CU/XLPE/PVC + 1x25mm² Y/G PVC CABLE LM

16.4.16 4x25mm² CU/XLPE/SWA/PVC + 1x16mm² Y/G PVC CABLE LM

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 272/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
16.4.17 4x35mm² CU/XLPE/SWA/PVC LM

16.4.19 4x10mm² CU/XLPE/SWA/PVC + 1x10mm² Y/G PVC CABLE LM

16.4.20 4x16mm2 CU/XLPE/PVC/PVC +1X16mm² Y/G PVC LM


16.4.21 4x10mm² CU/PVC/PVC+1x10mm² Y/G PVC CABLE LM
16.4.22 5x6mm² CU/PVC/PVC CABLE LM
16.4.23 3x6mm² CU/PVC/PVC CABLE LM

16.50 Isolating switches

Supply, install, test and commission Isolating switch


points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.5.1 25A, SPN ,IP65 No.


16.5.2 25A, TPN ,IP65 No.
16.5.3 32A, SPN ,IP65 No.
16.5.4 32A, TPN ,IP65 No.
16.5.5 32A, SPN ,IP54 for D.W No.
16.5.6 40A, TPN ,IP65 No.
16.5.7 50A, TPN ,IP65 No.
16.5.8 63A, TPN ,IP66 No.
16.5.9 80A, TPN ,IP65 No.
16.5.10 100A, TPN ,IP65 No.

16.60 Power Socket Outlets


Sections 16020, 16120, 16130 ,16140

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 273/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, test and commission Socket outlet


pints only including all necessary PVC conduits,
wires, cables, pull and junctions boxes , floor boxes
(where needed as per drawings) ,cover plates ,
ancillaries , connections, and all needed accessories
as shown on the drawings . excluding outlet device
and face plate .

Socket outlet, 13A, 1- phase, 1- gang , switched (wall or


16.6.1 No.
in floor mounted box)

16.6.2 Ditto but ceiling mounted No.

16.6.3 Ditto but water proof No.

16.6.4 Ditto but double gang(wall or in floor mounted box) No.

16.6.5 Ditto but double gang water proof No.

16.6.6 Power points for motorized shutter No.

16.6.7 Spur outlet for electrical water heater No.

16.6.9 Power points for hand & hair ddryer No.

16.6.13 Power points for Jaccuzi OR Fountains No.

20A, double pole switch with neon.


16.6.8 No.

Socket outlet, 15A, 1- phase, 1- gang , for washer or


16.6.10 No.
dryer

16.6.11 Ditto but 3-phase No.

16.6.11.1 FLOOR BOX 2P+1D No.

16.6.11.2 FLOOR BOX 1P+1TV No.

16.6.11.3 FLOOR BOX 2P+1D+1TV No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 274/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
WIRING DEVICES :

INSTALL ONLY ( SUPPLY BY OTHERS) WIRING


DEVICES INCLUDES ALL ACCESSORIES , (GFCI)

Single Switched socket 13A,220v (2P+E) Grounding type


16.6.14 NO

16.6.15 Double socket 13A,220v (2P+E),Grounding type NO

Single socket 13A,220v (2P+E) GFCI,with earth leakage


16.6.16 NO
protection

celing power socket 13A ,220v for AC (2P+E)


16.6.17 NO
Grounding type

16.6.18 Single socket 20A,220v (2P+E) FOR WATER HEATER NO

16.6.19 2phase socket 20A,220v (3P+E) with neon type, NO

SUPPLY AND INSTALL WIRING DEVICES


INCLUDES ALL ACCESSORIES (GFCI)
for maid , laundary, storage rooms

SUPPLY AND INSTALL Single Switched socket 13A,220v


16.6.21 NO
(2P+E) Grounding type (legrand/MK) or eqivelant

16.6.22 Double socket 13A,220v (2P+E),Grounding type NO

wall power socket 32 A ,220v for AC (2P+E) Grounding


16.6.23 type WATHER PROOF NO

16.70 Lighting System


Sections 16010, 16120 ,16510

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 275/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, test and commission Lighting points


with all necessary conduits, conductors , cables &
wires , junction , pull boxes, connections,
accessories, fittings, and all needed accessories as
shown on the drawings.

16.7.1 Internal Lighting points with wire size 2.5 mm2 No.

16.7.2 External Lighting points with wire size 6 or 10 mm2 No.

16.80 Lighting Fixtures


Sections 16010, 16120 ,16510

install only test and commission Lighting fixtures


and switches with all necessary accessories and
termination as shown on the drawings.

16.8.1 Type F1 No.


16.8.2 Type F2 No.
16.8.3 Type F3 No.
16.8.4 Type F4 No.
16.8.5 Type F5 No.
16.8.6 Type F6 No.
16.8.7 Type F7 No.
16.8.8 Type F8 No.
16.8.9 Type F9 No.
16.8.10 Type F11 No.
16.8.11 Type F12 No.
16.8.13 Type F14 No.
16.8.14 Type F14E No.
16.8.15 Type F15 No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 276/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
16.8.16 Type F15E No.
16.8.17 Type F18 No.
16.8.18 Type F19 No.
16.8.20 Type EX1 No.
16.8.21 Type EX3 No.
16.8.22 Type EX4 No.
16.8.23 Type EX5 No.
16.8.24 Type EX6 No.
supply and install,test and commission Lighting
fixtures and lighting switches (All fixtures shall be
supplied in full coordination with client or client's
representative) including all necessary transformer
ballast, switch gear, lamps, lamp holders, diffusers,
internal wires, supports, clamps, conduits,
connections, terminations, fixings, fittings and all
needed accessories and as shown on the drawings.
for maid, laundary, storage rooms

16.8.25 Type F1 No.


16.8.26 Type F4 No.
16.8.27 Type F9 No.
16.8.29 Type F14 No.
16.8.30 Type F15 No.
16.8.31 Type F15E No.
16.8.32 Type F19 No.

16.90 Fire Alarm Installation


Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reSet button, switches,
batteries, charger, internal conductor, enclosure and all
16.9.1
other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 277/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

16.9.1.1 Fire alarm Slave panel, ref. SACP-DW (1 loop) No.


16.9.1.2 Fire alarm Slave panel, ref. SACP-G.V (1 loop) No.
16.9.1.3 Fire alarm Slave panel, ref. SACP-M.V (1 loop) No.
16.9.1.4 Fire alarm Slave panel, ref. SACP-A.V (1 loop) No.
16.9.1.5 Fire alarm Slave panel, ref. SACP-D.A/X (1 loop) No.
16.9.1.6 Fire alarm Slave panel, ref. SACP-C.H (1 loop) No.
16.9.1.7 Fire alarm Slave panel, ref. SACP-M&N (3 loops) No.
16.9.1.8 Fire alarm Slave panel, ref. SACP-DM&N (1 loop) No.
16.9.1.9 Fire alarm Slave panel, ref. SACP-A.V (1 loop) No.

16.9.1.10 Fire alarm Slave panel, ref. SACP-M.V/X (X: R, L) (1 loop) No.

16.9.1.11 Fire alarm Slave panel, ref. SACP-DI&A (1 loop) No.


16.9.1.12 Fire alarm Slave panel, ref. SACP-I.V (1 loop) No.
16.9.1.13 Fire alarm Slave panel, ref. SACP-AE.V (1 loop) No.

Addressable Fire alarm devices including covers,


fixings ,conductors, conduits, pull and junction boxes,
16.9.2
cables, wires, connections and terminations, and all
needed accessories as shown on the drawings.

16.9.2.1 Addressable smoke detector No.


16.9.2.2 Ditto but with sound base No.
16.9.2.3 Addressable heat detector No.
16.9.2.4 Ditto but with sound base No.
16.9.2.5 Break glass station No.
16.9.2.6 Audible/visual warning devices indoor No.
16.9.2.7 Audible/visual warning devices outdoor No.

16.10 EARTHING SYSTEM


Sections 16125 EARTHING

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 278/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,8 earthing pits, various
corner earthing points of the building , connected with
16.10.1 ls
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building ,
16.10.2 ls
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.11 CCTV SYSTEM

Sections 16690 IP network components,16690 ,


16738,16739

supply and Install only indoor cameras's points including


all necessary empty PVC conduits from data cabinet to
16.11.4 point's location , pull junction boxes, and all needed
accessories as per drawings.

16.12 LOW CURRENT SYSTEMS

Sections 16110, 16120, 16130, 16140, 16690


IP network

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 279/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #
components,16700 ,16738,16739

Voice & Data Distribution System

Supply and install of voice & data distribution Equipment,


including but not limited to connections, supports , patch
panel , distributer switches , ends of cables ,data rack 9u
cabenit and all necessary accessories; all in accordance
with the Drawings and Specifications and as approved by
16.12.1.1 owner .  set
A) the main
distributor (SWITCH to connect devices not less than
1000 MB .
B) Distributor SWITCH devices to
wall outlet not less than 100 MB (By Others )

Supply, install, test and commission voice & data


distribution circuit points , including all ,
fixings ,wires, cat6 A ,cable terminals, cable trunks
and trays ,conduits, pull and junction boxes, floor
suuports (where needed as per drawings) ,cover
plates , connections from data rack to the outlet, and
all needed accessories as shown on the drawings.
excluding outlet device and face plate .

16.12.1 RJ45 socket outlet wall No.

16.12.2 Access point installed above false ceiling No.

16.12.3 RJ45 Data socket outlet , installed in floor mounted box No.

16.12.4 RJ45 access point installed above faL.Se ceiling No.

RJ45 socket outlet used for IP- camera (only for


16.12.5 No.
outdoor type and for indoor at main diwaniah & gust villa)

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 280/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply and installation of reception satellite system


including reception and rules dishes , receivers,
amplifiers , LNP, links, boxes and dividers with
16.12.5.1 LS
adjustment, calibration, operation and delivery ,
programming of required stations and all in
accordance with the details shown on drawings

supply and install installation and test Mural TV socket


outlet includes boxes, coaxial cables , pipes , conduits
16.12.5.2 No.
and all needed accessories , excluding outlet device and
face plate .

Supply, install, test and commission Inter come system


includs indoor unit , out door unit , 2P cables and
16.14 LS
connections , PVC conduits , power supply , and all
needed accessories and as shown on the drawings .

Elevators & Dumbwaiter electrical work related


16.16 only )

install, test and commission an electrical feeding points


16.16.1 for electrical elevators , with all necessary equipment No.
(for specification refer to CONVEYING SYSTEM div 14.1)

16.16.2 Ditto but for dumbwaiter No.

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 281/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, test and commission (6W) Ceiling metallic


16.17 loudspeaker (Recessed) complete with wires , and all No.
needed accessories as shown on the drawings.

Supply, install, test and commission (10W) Ceiling


16.18 metallic loudspeaker wall mounted complete with wires , No.
and all needed accessories as shown on the drawings

16.19 Ditto but weather proof No.

Supply, install, test and commission Music Rack located


at control room at roof complete with wires, conduits ,
Amplifiers , power supply , back up batteries, AM/FM
digital tuner , DVD player, MP3 player , CD player ,
16.20. LS
CasSette player , Portable UHF- Band Wireless
microphone (complet with receiver and transmitter) ,
microphone , and all needed accessories as shown on the
drawings

DIV#16 Total cost of this section Carried Forward To Summary 0

*** NOTE:-

Item overlooked in the bill of quantity but shown


in drawings, specification and schedules
necessary for the satisfactory completion of the
works may be priced hereunder.

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary -

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 282/2284


DIVISION # 1~16 / ALL DISCIP

REMARKS

ITEM DIV
DESCRIPTION UNIT
# #

431100001.xlsx/B 1~12 /07/26/2019 QS/Baig 283/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 284/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 285/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 286/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 287/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No.


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 288/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 289/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 290/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3

3.1.2 Blinding, 50mm thick under slabs on grade m3

3.1.4 Blinding, 50mm thick under all types of tie beams m3

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3

3.2.1.1 Foundations; (Raft , continous )

3.2.2 Tie beams - Intermediate m3

3.2.3 Upper tie beams m3

3.2.4 Slabs on grade m3

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 291/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
3.2.5 Walls below slab on grade m3

3.2.6 Columns Below slab on grade m3

3.2.7 Water Tanks Slabs and Walls m3

3.2.8 Swimming pool Slabs and Walls m3

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3

3.3.2 Shear Walls , free standing walls above slab on Grade m3

3.3.3 Suspended solid slabs; including drop beams m3

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2

3.3.5 Stairs (steps, flights and landing) m3

3.3.6 Beams m3

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 292/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2


3.4.2.1 Below slab on grade for basements -Horizontal
3.4.2.2 Water Tanks
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 293/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 294/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 295/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2


moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 296/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
7.1.3 Supply, install and test of the liquid applied m2
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 297/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 298/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 299/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No.

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No.

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No.

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No.

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No.

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No.

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 300/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
8.3.2 Ditto but Size : 2.2× 1.5 meter No.

8.3.3 METAL WINDOW Height 1 × 2 meter width No.

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No.


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No.

8.4.4.2 For wide 0.60 No.

8.4.4.3 For wide 0.90 No.

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 301/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2

9.1.2 Plastering to walls internal sides. m2

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 302/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2

9.2.12 L.G.B = LAMINATED GYPSUM m2


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 303/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No.

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2

9.3.32 Paint for walls m2

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2

9.4.3 CIRAMIC TILES (200*200*8)mm m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 304/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 305/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

9.5.15 Glass wall in the main gate H 1.2 No.

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 306/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M.

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 307/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM

Ladder

10.3.6 Supply and installation of galvanized iron ladder No.


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 308/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 309/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 310/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 311/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 312/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM

15.1.1.2 25 mm outside diameter pipe LM

15.1.1.3 32 mm outside diameter pipe LM

15.1.1.4 40 mm outside diameter pipe LM

15.1.1.5 50 mm outside diameter pipe LM

15.1.1.6 63 mm outside diameter pipe LM

15.1.1.7 80 mm outside diameter pipe LM

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 313/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm
15.1.1.15 Gate vlave Ø 32 mm
15.1.1.16 Gate vlave Ø 40 mm
15.1.1.17 Gate vlave Ø 50 mm
15.1.1.18 Gate vlave Ø 90 mm

15.1.2 Electric Water Heaters

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No.

15.1.2.3 EWH-3 (80 Liter ) No.

15.1.2.4 EWH-4 (100 Liter) No.

15.1.3 Domestic Cold water tank

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 314/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No.

15.1.5 Pumps

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set

15.1.6 Domestic Water Booster Set

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 315/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set

15.2 FIRE FIGHTING SYSTEM


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 316/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No.

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No.

15.3 PLUMBING FIXTURE APPLIANCES

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 317/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01
15.3.1.2 WC-02 I

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 )
15.3.2.2 ( Lav-02 )

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 318/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No.

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No.

15.4 STORMWATER AND DRAINAGE SYSTEM

15.4.1 Pipework

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 319/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.4.1.2 80 mm diameter pipe LM

15.4.1.3 110 mm diameter pipe LM

15.4.1.4 160 mm diameter pipe LM

15.4.1.4.1 200 mm diameter pipe

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No.

15.4.1.6 FD-110 mm outlet diameter No.

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 320/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.4.1.8 WCO- 110mm No.

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No.


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 321/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No.

15.4.1.16 RD, 75mm outlet diameter No.

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 322/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No.

15.5 HVAC SYSTEM


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 323/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No.

15.5.3.2.1.13 WDX-02 -1.5TR No.

15.5.3.2.1.14 WDX-03 -2TR No.

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 324/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No.

15.5.4.43.2 FAF-B-014 No.

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan

15.5.4.87 EXF-B13-B-01 No.

15.5.4.88 EXF-B14-B-01 No.

15.5.4.89 EXF-B16-01 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 325/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
15.5.4.90 EXF-B17-01 No.

15.5.4.90.1 AEX-B02-01 NO
15.5.4.90.2 AEX-B04-02

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No.

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO

15.5.4.100 EXF-B17-2 NO

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 326/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.5.5 Condensate Pipework

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM

15.5.6 Ductwork

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 327/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No.
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No.
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 328/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No.

15.5.9.69 EAL-B14-01 No.

15.6.9 Diesel Tank


Supply install test and commison daily tank for
15.6.9.1 No.
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 329/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.7.1 PVC Pipes

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM

15.7.1.2 32 mm LM

15.7.1.3 40 mm LM

15.7.1.4 50 mm LM

15.7.1.5 63 mm LM

15.7.1.6 75 mm LM

15.7.1.7 110 mm LM

15.7.1.8 160mm LM

15.7.2 Swimming pool pump

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 330/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.7.2.7 FP-B19-1 No.

15.7.3 Inlet Fitting

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No.

15.7.4 Vacuum Fitting

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No.

15.7.5 Main Drain

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No.

15.7.6 Overflow Trench Fitting

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 331/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM

15.7.7 Outlet Fitting

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No.

15.7.8 Fill Fitting

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No.

15.7.9 Pool Sand Filter

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 332/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.7.9.4 SF-B19-1 Set.

15.7.10 Chemical Feeding and Control Accessories

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No.

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No.

15.7.10.3 Chemical test kit No.

15.7.11 Balance Tank

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No.

15.7.12 Electrical Heat Exchanger

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 333/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No.

15.8 MECH. GENERAL SITE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 334/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No.


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No.
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No.

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No.


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No.
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No.

15.8.2 SITE WATER DISTRIBUTION

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 335/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.8.2.1 20 mm. L.M


15.8.2.2 25 mm. L.M
15.8.2.3 32 mm. L.M
15.8.2.4 40 mm. L.M
15.8.2.5 50 mm. L.M
15.8.2.6 63 mm. L.M
15.8.2.7 80 mm. L.M

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No.
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No.
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No.

15.8.3 FIRE FIGHTING PIPING (VOID ITEM)

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M


15.8.3.2 Diam 150mm (6") L.M

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 336/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 337/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No.
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set

15.8.4 SEWER & STORM PIPING

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M


15.8.4.2 Diam 200mm (8") L.M

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 338/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

LPG PIPING AND TANK


15.8.5

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No.

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M


15.8.5.3 Diam 32mm L.M
15.8.5.4 Diam 40mm L.M

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No.
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 339/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.8.6.2 F-B18-02 Set.

15.8.6.3 F-B18-03 Set.

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set.

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set.

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 340/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

15.8.6.8 IRRP-B18-02 Set.

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set.

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No.


16.21.2 Ref. SMDB-S No.
16.21.3 Ref. ESMDB-S No.
16.21.4 Ref. LV-1 No.
16.21.5 Ref. ELV-1 No.
16.21.6 Ref. LV-2 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 341/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
16.21.7 Ref. ELV-2 No.

16.22 Motor Control Center

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No.


16.22.2 Ref. MCC-R No.
16.22.3 Ref. MCC-B18 No.
16.22.4 Ref. MCC-B19 No.

16.23 Distribution Boards

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No.
16.23.6 Ref. DL-B/R No.
16.23.7 Ref. DB-G/R No.
16.23.8 Ref. EDB-B/C1 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 342/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
16.23.9 Ref. EDB-S/S1 No.
16.23.10 Ref. EDB-S/S2 No.
16.23.11 Ref. EDB-B/C2 No.

16.24 Feeder Pillar

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No.
16.24.2 Ref. LPEX2 No.

16.25 Feeders

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 343/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No.


16.26.3 32A, SPN ,IP65 No.
16.26.4 32A, TPN ,IP65 No.

16.27 Power Socket Outlets

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No.


in floor mounted box)
16.27.2 Ditto but ceiling mounted No.
16.27.3 Ditto but water proof No.
16.27.4 Ditto but double gang (wall or in floor mounted box) No.
16.27.7 Spur outlet for electrical water heater No.
16.27.8 20A, double pole switch with neon. No.
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No.
dryer
16.27.12 Power points for Motorized Camera No.

16.28 Lighting System


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 344/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No.


16.28.2 External Lighting points No.

16.29 Lighting Fixtures

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No.


16.29.4 Type F4 No.
16.29.5 Type F5 No.
16.29.6 Type F6 No.
16.29.8 Type F8 No.
16.29.9 Type F9 No.
16.29.11 Type F11 No.
16.29.16 Type F15 No.
16.29.17 Type F15E No.
16.29.21 Type F19 No.
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 345/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
16.29.25 Type EX3 No.
16.29.26 Type EX4 No.
16.29.27 Type EX5 No.
16.29.28 Type EX6 No.
16.29.29 Type EX7 No.
16.29.30 Type EX8 No.
16.29.31 Type EX9 No.
16.29.32 Type EX10 No.
16.29.33 Type EX11 No.
16.29.42 Type EX20 No.
16.29.43 Type EXT. 1 No.
16.29.44 Type EXT. 2 No.
16.29.45 Type EXT. 3 No.
16.29.47 Type EXT. 5 No.
16.29.48 Type EXT. 6 No.

16.3 Fire Alarm Installation

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No.
Repeater Fire alarm control panel,ref.RE.MFACP-M (20
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 346/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires,
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No.


16.30.2.2 Addressable smoke detector with sound base No.
16.30.2.3 Addressable heat detector No.
16.30.2.4 Addressable heat detector with sound base No.
16.30.2.5 Break glass station No.
16.30.2.6 Audible/visual warning devices indoor No.
16.30.2.7 Audible/visual warning devices outdoor No.
16.30.2.8 Control module (CM) No.
16.30.2.9 End of line resistane (E.O.L) No.

16.31 EARTHING SYSTEM

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 347/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No.


16.32.2 ref. M.D.C-2 No.

16.33 CCTV SYSTEM

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No.


16.33.2 Weather proof Fixed IP-camera , pole mounted No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 348/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No.

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No.

16.35.2 RJ45 data socket outletr in floor mounted box No.

RJ45 Data socket outlet , ceiling/ wall mounted , for IP-


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No.

16.35.5 RJ45 socket outlet for IP-TV -optional No.

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 349/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

MULTI-MODE 4-CORE FIBBER CABLES FOR all


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO)

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No.
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No.


16.37.2 150KVA Generator (G-2) No.

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as
shown on the drawings

16.38.1 400A ATS No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 350/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #
16.38.3 180A ATS No.
16.38.4 80A ATS No.
16.38.7 40A ATS No.
16.38.8 32A ATS No.

16.39 Conduits

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No.

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No.

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No.

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No.

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No.

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No.

16.39.7 Ø100 uPVC conduits L.M

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 351/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV
DESCRIPTION UNIT
# #

16.39.8 Ø75 uPVC conduits L.M

16.39.9 Ø50 uPVC conduits L.M

16.39.10 Ø32 uPVC conduits L.M

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 352/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS 0
0
DIV#1 Total cost of this section Carried Forward To Summary 0
0
0
2 DIV#2 SITE WORKS 0
PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone 0
Excluded- At this stage 0
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM 0
concrete curbstone, complete with all the 0
required components including preparation of 0
underneath layer & blinding concrete as 0
specified in the drawings 0
0
Cement Tiles / Pavers 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 353/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2 0
walkway areas round the building, complete with all 0
the required components to complete the work 0
including preparation of underneath layer and as 0
specified in drawings and specifications. 0
0
Car Driveway 0
Excluded- At this stage 0
2.1.4 General preparations as per design levels and laying m2 0
of asphalt concrete pavement on level sub base 0
surface compacted density not less than 95% 0
including grubbing and grading to proposed design 0
levels with the following components as specified in 0
the drawings and specification including paint 0
marking as follows: 0
-200 mm stabilized aggregate base course 0
-MC1 spray application 0
-70 mm thick bituminous base course 0
-RC2 spray application 0
-30 mm thick bituminous wearing / surface course 0
-Paint marking 0
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No. 0
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 354/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 355/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 356/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 357/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 358/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0
0
DIV#2 Total cost of this section Carried Forward To Summary 0
0
0
3 DIV#3 CONCRETE WORKS 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 359/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene 0
sheets) 250 micron,

0
3.1.1 Blinding, 100mm thick under foundations m3 0
0
3.1.2 Blinding, 50mm thick under slabs on grade m3 0
0
0
3.1.4 Blinding, 50mm thick under all types of tie beams m3 0
0
Cyclopean concrete; comprising of 50:50 plain concrete 0
and stone
0
3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0
0
Reinforced cast in situ concrete (grade 30), 30N/mm2
,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0


0
3.2.1.1 Foundations; (Raft , continous ) 0

0
3.2.2 Tie beams - Intermediate m3 0
0
3.2.3 Upper tie beams m3 0
0
3.2.4 Slabs on grade m3 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 360/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
3.2.5 Walls below slab on grade m3 0
0
3.2.6 Columns Below slab on grade m3 0
0
3.2.7 Water Tanks Slabs and Walls m3 0
0
3.2.8 Swimming pool Slabs and Walls m3 0
0
3.2.9 Car Park Roof Slab m3 0
0
0
Reinforced cast in situ concrete (grade 30), 30N/mm2
,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

0
3.3.1 Columns above slab on grade m3 0
0
3.3.2 Shear Walls , free standing walls above slab on Grade m3 0
0
3.3.3 Suspended solid slabs; including drop beams m3 0
0
Ribbed slabs;including hollow concrete blocks and hidden
3.3.4 beams -Ribs m2 0

0
3.3.5 Stairs (steps, flights and landing) m3 0
0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 361/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0


0
0
4 DIV#4 MASONRY WORKS 0
0
Concrete masonry units (CMU) for external and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 362/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
internal wall partitions as specified and shown 0
in the drawings and specifications. Price shall 0
include all anchors, joints, mortar, sills & lintels, 0
jambs (if any), vertical & horizontal 0
reinforcement, tests and all other related works 0
to complete all masoNo.ies as specified in the 0
drawings & specifications i.e. (04200, 04422) 0

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2 0


internal / partition walls 0
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 363/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design . 0
0
DIV#4 Total cost of this section Carried Forward To Summary 0
0
0
5 DIV#5 METAL WORKS LS 0
0
NA 0
0
DIV#5 Total cost of this section Carried Forward To Summary 0
0
0
6 DIV#6 WOOD & PLASTIC LS 0
NA 0
0
DIV#6 Total cost of this section Carried Forward To Summary 0
0
0
7 DIV#7 THERMAL & MOISTURE 0
0
7.1 Waterproofing 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 364/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
Supply, installation and testing of the following 0
waterproofing, thermal and moisture protection 0
system over R.C. Slab (roof deck), including all 0
the necessary components and accessories to 0
complete the work as specified in the drawings and 0
specifications i.e. (07105, 07155, 07211, 07800, 0
07951) Price shall include for all vertical up-stand, 0
termination & mechanical fixations etc. (submit 0
details with ten years warranty for approval) 0
0
Exposed Roof Areas 0
0
7.1.1 Supply, install and test of the following thermal and m2 0
moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 365/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 366/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 367/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0
0
0
8 DIV#8 DOORS & WINDOWS 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 368/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Supply and installation of complete doors & 0
windows units including frame and all the 0
necessary hardware and accessories including 0
paint as specified in the drawing & specifications. 0
(08111, 08121, 08200, 08300, 08521, 08700, 0
08800) & special spesification for wooden doors 0
0
Note : Ditto = Matching code only 0
0
8.1 STEL & WOODEN DOORS 0
0
8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0
0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 369/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0
0
0
9.1 DIV#9 FINISHES 0
0
Plastering Works 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 370/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
20 mm thick Portland cement plaster (straight) in 0
two layers using 400KG cement to (1) m3 of clean 0
sand and smooth cement finish to concrete and 0
wall surfaces including wire mesh, lath and plaster 0
accessories as specified in the drawing and 0
specifications i.e. (09100, 09310, 09421, 09510, 0
09680, 09900, 09905) Price shall include interior 0
and exterior corner and angle beads, plaster stops, 0
control joints, acrylic sealant and forming of 0
groove as described to:- 0
0
9.1.1 Plastering to walls external sides. m2 0
0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 371/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 372/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 373/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 374/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 375/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0
0
0
10.1 DIV#10 SPECIALTIES 0

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in 0
related works .

SANITARY FIXTURES 0
0
Kitchen Accessories 0
Excluded- At this stage 0
Supply and installation of following kitchen fixtures 0
and accessories as specified. i.e. 10800 0
0
10.1.1 Kitchen cabinet, counter top with back splash, to 0
be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 376/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 377/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
DIV#10 Total cost of this section Carried Forward To Summary 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 378/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
11 DIV#11 EQUIPMENTS LS 0
NA 0
0
0
DIV#11 Total cost of this section Carried Forward To Summary 0
0
0
12 DIV#12 FURNITURE LS 0
NA 0
0
0
DIV#12 Total cost of this section Carried Forward To Summary 0
0
0
13 DIV#13 SPECIAL CONSTRUCTIONS 0
0
13.1 Sky Light 0
0
Supply and installation of colored glass panels with 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 379/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
geometric shapes to work on celestial lighting 0
slots, item includes outer frame, protection and 0
aluminum panels to strengthen the glass. 0
0
0
13.1.34 Type-34 Size : 28 × 2.4 meter No. 0
0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0
0
0
14 DIV#14 CONVEYING SYSTEM 0
0
NA 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 380/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 381/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
15 DIV#15 DIVISION 15 - MECHANICAL 0
0
15.1 DOMESTIC WATER SYSTEM 0
0
15.1.1 Pipework 0
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes 0
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
5.1.1.1 20 mm outside diameter pipe LM 0
0
5.1.1.2 25 mm outside diameter pipe LM 0
0
5.1.1.3 32 mm outside diameter pipe LM 0
0
5.1.1.4 40 mm outside diameter pipe LM 0
0
5.1.1.5 50 mm outside diameter pipe LM 0
0
5.1.1.6 63 mm outside diameter pipe LM 0
0
5.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 382/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
5.1.1.14 Gate vlave Ø 25 mm 0
5.1.1.15 Gate vlave Ø 32 mm 0
5.1.1.16 Gate vlave Ø 40 mm 0
5.1.1.17 Gate vlave Ø 50 mm 0
5.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
5.1.2.2 EWH-2 (50 Liter) No. 0
0
5.1.2.3 EWH-3 (80 Liter ) No. 0
0
5.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 383/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
5.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

5.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 384/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
5.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 385/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 386/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
5.3.1.1 WC-01 0
5.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
5.3.2.1 ( Lav-01 ) 0
5.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 387/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
5.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
5.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 388/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
5.4.1.2 80 mm diameter pipe LM 0
0
5.4.1.3 110 mm diameter pipe LM 0
0
5.4.1.4 160 mm diameter pipe LM 0
0
.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
5.4.1.5 FD-80 mm outlet diameter No. 0
0
5.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
5.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 389/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
5.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

5.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
5.4.1.11 set 0
5.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 390/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
5.4.1.15 RD, 110mm outlet diameter No. 0
0
5.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 391/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
5.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
5.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 392/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
5.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
5.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
5.3.2.1.12 WDX-01 - 1TR No. 0
0
5.3.2.1.13 WDX-02 -1.5TR No. 0
0
5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 393/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
5.4.43.1 FAF-B-013 No. 0
0
5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
5.5.4.55 Centrifugal in line fan 0
0
5.5.4.87 EXF-B13-B-01 No. 0
0
5.5.4.88 EXF-B14-B-01 No. 0
0
5.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 394/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
5.5.4.90 EXF-B17-01 No. 0
0
5.4.90.1 AEX-B02-01 NO 0
5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
5.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
5.5.4.99 EXF-B16-2 NO 0
0
.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 395/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
5.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 396/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
5.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
5.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
5.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
5.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 397/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
5.5.9.68 EAL-B13-01 No. 0
0
5.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
5.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 398/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
5.7.1.1 25 mm LM 0
0
5.7.1.2 32 mm LM 0
0
5.7.1.3 40 mm LM 0
0
5.7.1.4 50 mm LM 0
0
5.7.1.5 63 mm LM 0
0
5.7.1.6 75 mm LM 0
0
5.7.1.7 110 mm LM 0
0
5.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 399/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
5.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
5.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0
0
15.7.4 Vacuum Fitting 0
0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
5.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
5.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 400/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
5.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
5.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
5.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 401/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

5.7.9.4 SF-B19-1 Set. 0


0
5.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
5.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
5.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
5.7.10.3 Chemical test kit No. 0
0
5.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
7.11.2.1 BT-B22-1 No. 0
0
5.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 402/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
5.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 403/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
5.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
5.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
5.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
5.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
5.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
5.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 404/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
5.8.2.1 20 mm. L.M 0
5.8.2.2 25 mm. L.M 0
5.8.2.3 32 mm. L.M 0
5.8.2.4 40 mm. L.M 0
5.8.2.5 50 mm. L.M 0
5.8.2.6 63 mm. L.M 0
5.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
5.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
5.8.2.09 No. 0
related accessories as per dwg's.

0
5.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
5.8.3.1 Diam 100mm (4") L.M 0
5.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 405/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 406/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
5.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
5.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
5.8.4.1 Diam 160mm (6") L.M 0
5.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
5.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 407/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

5.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
5.8.5.2 Diam 25mm L.M 0
5.8.5.3 Diam 32mm L.M 0
5.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
5.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
5.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 408/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

0
5.8.6.2 F-B18-02 Set. 0
0
5.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
5.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

5.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
5.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 409/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0
5.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

5.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 410/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 411/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
16.23.9 Ref. EDB-S/S1 No. 0
6.23.10 Ref. EDB-S/S2 No. 0
6.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
6.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
6.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 412/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
6.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
6.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
6.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 413/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
6.29.11 Type F11 No. 0
6.29.16 Type F15 No. 0
6.29.17 Type F15E No. 0
6.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 414/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
6.29.25 Type EX3 No. 0
6.29.26 Type EX4 No. 0
6.29.27 Type EX5 No. 0
6.29.28 Type EX6 No. 0
6.29.29 Type EX7 No. 0
6.29.30 Type EX8 No. 0
6.29.31 Type EX9 No. 0
6.29.32 Type EX10 No. 0
6.29.33 Type EX11 No. 0
6.29.42 Type EX20 No. 0
6.29.43 Type EXT. 1 No. 0
6.29.44 Type EXT. 2 No. 0
6.29.45 Type EXT. 3 No. 0
6.29.47 Type EXT. 5 No. 0
6.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

6.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
6.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 415/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
6.30.2.1 Addressable smoke detector No. 0
6.30.2.2 Addressable smoke detector with sound base No. 0
6.30.2.3 Addressable heat detector No. 0
6.30.2.4 Addressable heat detector with sound base No. 0
6.30.2.5 Break glass station No. 0
6.30.2.6 Audible/visual warning devices indoor No. 0
6.30.2.7 Audible/visual warning devices outdoor No. 0
6.30.2.8 Control module (CM) No. 0
6.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 416/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 417/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 418/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
6.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 419/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 420/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

ITEM DIV UNIT PRICE (SR


DESCRIPTION UNIT
# #

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

6.39.10 Ø32 uPVC conduits L.M 0


0
0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 421/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 422/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 423/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 424/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 425/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No.


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 426/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 427/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 2895

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 1377

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2 402

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 428/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 18

3.1.2 Blinding, 50mm thick under slabs on grade m3 16

3.1.4 Blinding, 50mm thick under all types of tie beams m3 2

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 1

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 30

3.2.1.1 Foundations; (Raft , continous ) 38

3.2.2 Tie beams - Intermediate m3 19

3.2.3 Upper tie beams m3 19

3.2.4 Slabs on grade m3 63

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 429/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 77

3.2.6 Columns Below slab on grade m3 4

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 19

3.3.2 Shear Walls , free standing walls above slab on Grade m3 81

3.3.3 Suspended solid slabs; including drop beams m3 113

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 2

3.3.6 Beams m3 14

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 430/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 482

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 438


3.4.2.1 Below slab on grade for basements -Horizontal 313
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 431/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2 50


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2 89


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2 547


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 432/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2 16


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 433/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 263
moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM 65


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 434/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2 151
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 435/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 436/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 0


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 437/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 1

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 5

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 4

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 8

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 8

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 3

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 438/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No.

8.3.3 METAL WINDOW Height 1 × 2 meter width No.

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No.


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No.

8.4.4.2 For wide 0.60 No.

8.4.4.3 For wide 0.90 No.

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 439/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 585

9.1.2 Plastering to walls internal sides. m2 1324

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 170


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2 170


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 440/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 194

9.2.12 L.G.B = LAMINATED GYPSUM m2 61


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 37


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2 585


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 26

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 441/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No.

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2

9.3.32 Paint for walls m2 315

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2 929

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 185

9.4.3 CIRAMIC TILES (200*200*8)mm m2 75

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 442/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 443/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No.

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 77


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 240

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 58

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 444/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M. 40

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 445/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M 20

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM 15

10.3.4 Handrail to internal stairs LM 7

Ladder

10.3.6 Supply and installation of galvanized iron ladder No. 1


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 446/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 447/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 448/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 1

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 449/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 450/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 160

15.1.1.2 25 mm outside diameter pipe LM 130

15.1.1.3 32 mm outside diameter pipe LM 60

15.1.1.4 40 mm outside diameter pipe LM 45

15.1.1.5 50 mm outside diameter pipe LM 80

15.1.1.6 63 mm outside diameter pipe LM 30

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 451/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 1
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 1
15.1.1.17 Gate vlave Ø 50 mm 2
15.1.1.18 Gate vlave Ø 90 mm 1

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 0

15.1.2.3 EWH-3 (80 Liter ) No. 7

15.1.2.4 EWH-4 (100 Liter) No. 1

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 452/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 1

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 453/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 1

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 3

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 454/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 2

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 2

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 455/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 8
15.3.1.2 WC-02 I 2

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 8
15.3.2.2 ( Lav-02 ) 2

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 456/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 2

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 8

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 60

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 457/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 0

15.4.1.3 110 mm diameter pipe LM 159

15.4.1.4 160 mm diameter pipe LM 10

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 2

15.4.1.6 FD-110 mm outlet diameter No. 10

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 458/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 2

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 1


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 459/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 3

15.4.1.16 RD, 75mm outlet diameter No. 0

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 2

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 460/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 6

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 1
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 461/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 1
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 3

15.5.3.2.1.13 WDX-02 -1.5TR No. 10

15.5.3.2.1.14 WDX-03 -2TR No. 2

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 462/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 1

15.5.4.43.2 FAF-B-014 No. 0

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 1

15.5.4.88 EXF-B14-B-01 No. 0

15.5.4.89 EXF-B16-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 463/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 0

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 4

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 0

15.5.4.100 EXF-B17-2 NO 0

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 464/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 180

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 465/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 600
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 1
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 1
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 4

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 466/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 1

15.5.9.69 EAL-B14-01 No. 0

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 467/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 468/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 0

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 469/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 470/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 0

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 471/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 0

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 472/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 473/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 474/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 475/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 476/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 477/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 0

15.8.6.3 F-B18-03 Set. 0

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 478/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 479/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 0

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 1


16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 1
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 480/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0

16.24 Feeder Pillar 0

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 70
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 100
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 481/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 6


16.26.3 32A, SPN ,IP65 No. 2
16.26.4 32A, TPN ,IP65 No. 11

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 36


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 18
16.27.3 Ditto but water proof No. 15
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 2
16.27.7 Spur outlet for electrical water heater No. 8
16.27.8 20A, double pole switch with neon. No. 8
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 8
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 482/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 64


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 9


16.29.4 Type F4 No. 12
16.29.5 Type F5 No. 4
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 15
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 10
16.29.16 Type F15 No. 10
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 4
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 483/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 484/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 2


16.30.2.2 Addressable smoke detector with sound base No. 16
16.30.2.3 Addressable heat detector No. 1
16.30.2.4 Addressable heat detector with sound base No. 1
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 2
16.30.2.7 Audible/visual warning devices outdoor No. 3
16.30.2.8 Control module (CM) No. 5
16.30.2.9 End of line resistane (E.O.L) No. 5

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 1
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 485/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 0


16.32.2 ref. M.D.C-2 No. 0

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 4


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 3

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 486/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 11

16.35.2 RJ45 data socket outletr in floor mounted box No. 5

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 7


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 4

16.35.5 RJ45 socket outlet for IP-TV -optional No. 1

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 487/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 488/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 489/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B13


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 490/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 491/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 492/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 493/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 494/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 495/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 496/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 497/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 498/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 499/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 500/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 501/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 502/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 503/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 504/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 505/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 506/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 507/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 508/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 509/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 510/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 511/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 512/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 513/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 514/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 515/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 516/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 517/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 518/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 519/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 520/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 521/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 522/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 523/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 524/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 525/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
15.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
15.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 526/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
15.4.1.2 80 mm diameter pipe LM 0
0
15.4.1.3 110 mm diameter pipe LM 0
0
15.4.1.4 160 mm diameter pipe LM 0
0
15.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
15.4.1.5 FD-80 mm outlet diameter No. 0
0
15.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 527/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
15.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 528/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
15.4.1.15 RD, 110mm outlet diameter No. 0
0
15.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 529/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 530/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
15.5.3.2.1.12 WDX-01 - 1TR No. 0
0
15.5.3.2.1.13 WDX-02 -1.5TR No. 0
0
15.5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 531/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
15.5.4.43.1 FAF-B-013 No. 0
0
15.5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
15.5.4.55 Centrifugal in line fan 0
0
15.5.4.87 EXF-B13-B-01 No. 0
0
15.5.4.88 EXF-B14-B-01 No. 0
0
15.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 532/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
15.5.4.90 EXF-B17-01 No. 0
0
15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.99 EXF-B16-2 NO 0
0
15.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 533/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
15.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 534/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
15.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 535/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
15.5.9.68 EAL-B13-01 No. 0
0
15.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 536/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
15.7.1.1 25 mm LM 0
0
15.7.1.2 32 mm LM 0
0
15.7.1.3 40 mm LM 0
0
15.7.1.4 50 mm LM 0
0
15.7.1.5 63 mm LM 0
0
15.7.1.6 75 mm LM 0
0
15.7.1.7 110 mm LM 0
0
15.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 537/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
15.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0


0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
15.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 538/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
15.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
15.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 539/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

15.7.9.4 SF-B19-1 Set. 0


0
15.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
15.7.10.3 Chemical test kit No. 0
0
15.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
15.7.11.2.1 BT-B22-1 No. 0
0
15.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 540/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
15.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 541/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 542/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
15.8.2.1 20 mm. L.M 0
15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

0
15.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
15.8.3.1 Diam 100mm (4") L.M 0
15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 543/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 544/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
15.8.4.1 Diam 160mm (6") L.M 0
15.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
15.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 545/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
15.8.5.2 Diam 25mm L.M 0
15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 546/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

0
15.8.6.2 F-B18-02 Set. 0
0
15.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
15.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 547/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0
15.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary 0

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 548/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. #VALUE!
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 549/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 550/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
16.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 551/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 0
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 552/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 553/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
16.30.2.1 Addressable smoke detector No. 0
16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 554/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 555/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 556/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 557/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 558/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 1

ITEM DIV B13


DESCRIPTION UNIT
# # Amount

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0


0

DIV#16 Total cost of this section Carried Forward To Summary 0

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 559/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 560/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 561/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 562/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 563/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No.


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 564/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 565/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 8244

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 5082

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 566/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 34

3.1.2 Blinding, 50mm thick under slabs on grade m3 29

3.1.4 Blinding, 50mm thick under all types of tie beams m3 5

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 1

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 31

3.2.1.1 Foundations; (Raft , continous ) 92

3.2.2 Tie beams - Intermediate m3 15

3.2.3 Upper tie beams m3 32

3.2.4 Slabs on grade m3 113

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 567/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 147

3.2.6 Columns Below slab on grade m3 4

3.2.7 Water Tanks Slabs and Walls m3 39

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 7

3.3.2 Shear Walls , free standing walls above slab on Grade m3 164

3.3.3 Suspended solid slabs; including drop beams m3 192

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 3

3.3.6 Beams m3 11

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 568/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 720

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 1350


3.4.2.1 Below slab on grade for basements -Horizontal 600
3.4.2.2 Water Tanks 148
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 46

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 569/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2 50


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2 158


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2 8


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2 570


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2 32

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 570/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2 25


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 571/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 320
moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM 85


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 572/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2 40
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 573/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 574/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 95


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 575/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 3

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 3

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 12

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No.

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 18

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 3

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 576/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No.

8.3.3 METAL WINDOW Height 1 × 2 meter width No.

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No.


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No.

8.4.4.2 For wide 0.60 No.

8.4.4.3 For wide 0.90 No.

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 577/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 610

9.1.2 Plastering to walls internal sides. m2 1934

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 391


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2 391


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 578/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 256

9.2.12 L.G.B = LAMINATED GYPSUM m2 60


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 28


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2 610


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 30

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 579/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No.

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2

9.3.32 Paint for walls m2

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2 1389

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 306

9.4.3 CIRAMIC TILES (200*200*8)mm m2 254

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 580/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 581/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No.

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 71


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 377

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 38

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 582/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M. 40

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 583/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M 20

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM 7

Ladder

10.3.6 Supply and installation of galvanized iron ladder No. 1


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET 1

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 1
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 584/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 585/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 586/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 1

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 587/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 588/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 200

15.1.1.2 25 mm outside diameter pipe LM 150

15.1.1.3 32 mm outside diameter pipe LM 70

15.1.1.4 40 mm outside diameter pipe LM 25

15.1.1.5 50 mm outside diameter pipe LM 210

15.1.1.6 63 mm outside diameter pipe LM 30

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 589/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 1
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 1
15.1.1.18 Gate vlave Ø 90 mm 1

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 4

15.1.2.3 EWH-3 (80 Liter ) No. 4

15.1.2.4 EWH-4 (100 Liter) No. 1

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 590/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 1

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 1

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 591/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 1

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 5

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 592/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 2

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 2

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 593/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 10
15.3.1.2 WC-02 I 1

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 10
15.3.2.2 ( Lav-02 ) 1

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 594/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 2

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 10

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 50

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 595/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 0

15.4.1.3 110 mm diameter pipe LM 280

15.4.1.4 160 mm diameter pipe LM 10

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 3

15.4.1.6 FD-110 mm outlet diameter No. 12

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 596/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 10

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 597/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 2

15.4.1.16 RD, 75mm outlet diameter No. 0

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 2

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 598/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 2

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 1
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 599/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 1
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 10

15.5.3.2.1.13 WDX-02 -1.5TR No. 10

15.5.3.2.1.14 WDX-03 -2TR No. 1

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 600/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 0

15.5.4.43.2 FAF-B-014 No. 1

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 0

15.5.4.88 EXF-B14-B-01 No. 1

15.5.4.89 EXF-B16-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 601/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 0

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 2

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 0

15.5.4.100 EXF-B17-2 NO 0

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 602/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 150

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 603/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 850
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 1
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 1
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 604/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 0

15.5.9.69 EAL-B14-01 No. 1

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 605/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 606/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 0

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 607/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 608/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 0

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 609/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 0

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 610/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 611/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 612/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 613/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 614/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 615/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 0

15.8.6.3 F-B18-03 Set. 0

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 616/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 1


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 617/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 0

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 1


16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 1
16.23.7 Ref. DB-G/R No. 1
16.23.8 Ref. EDB-B/C1 No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 618/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0

16.24 Feeder Pillar 0

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 220
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 10
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 15
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 85
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 619/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 5


16.26.3 32A, SPN ,IP65 No. 2
16.26.4 32A, TPN ,IP65 No. 17

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 80


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 22
16.27.3 Ditto but water proof No. 19
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 2
16.27.7 Spur outlet for electrical water heater No. 9
16.27.8 20A, double pole switch with neon. No. 9
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 3
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 620/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 93


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 20


16.29.4 Type F4 No. 14
16.29.5 Type F5 No. 4
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 26
16.29.9 Type F9 No. 6
16.29.11 Type F11 No. 9
16.29.16 Type F15 No. 8
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 6
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 621/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 622/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 5


16.30.2.2 Addressable smoke detector with sound base No. 25
16.30.2.3 Addressable heat detector No. 1
16.30.2.4 Addressable heat detector with sound base No. 1
16.30.2.5 Break glass station No. 3
16.30.2.6 Audible/visual warning devices indoor No. 2
16.30.2.7 Audible/visual warning devices outdoor No. 2
16.30.2.8 Control module (CM) No. 4
16.30.2.9 End of line resistane (E.O.L) No. 4

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 1
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 623/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 0


16.32.2 ref. M.D.C-2 No. 0

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 4


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 624/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 19

16.35.2 RJ45 data socket outletr in floor mounted box No. 2

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 6


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 5

16.35.5 RJ45 socket outlet for IP-TV -optional No. 2

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 625/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 626/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 627/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Bu

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 628/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 629/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 630/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 631/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 632/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 633/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 634/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 635/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 636/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 637/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 638/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 639/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 640/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 641/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 642/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 643/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 644/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 645/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 646/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 647/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 648/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 649/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 650/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 651/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 652/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 653/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 654/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 655/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 656/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 657/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 658/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 659/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 660/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 661/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 662/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 663/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
15.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
15.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 664/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
15.4.1.2 80 mm diameter pipe LM 0
0
15.4.1.3 110 mm diameter pipe LM 0
0
15.4.1.4 160 mm diameter pipe LM 0
0
15.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
15.4.1.5 FD-80 mm outlet diameter No. 0
0
15.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 665/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
15.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 666/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
15.4.1.15 RD, 110mm outlet diameter No. 0
0
15.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 667/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 668/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
15.5.3.2.1.12 WDX-01 - 1TR No. 0
0
15.5.3.2.1.13 WDX-02 -1.5TR No. 0
0
15.5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 669/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
15.5.4.43.1 FAF-B-013 No. 0
0
15.5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
15.5.4.55 Centrifugal in line fan 0
0
15.5.4.87 EXF-B13-B-01 No. 0
0
15.5.4.88 EXF-B14-B-01 No. 0
0
15.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 670/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
15.5.4.90 EXF-B17-01 No. 0
0
15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.99 EXF-B16-2 NO 0
0
15.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 671/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
15.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 672/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
15.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 673/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
15.5.9.68 EAL-B13-01 No. 0
0
15.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 674/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
15.7.1.1 25 mm LM 0
0
15.7.1.2 32 mm LM 0
0
15.7.1.3 40 mm LM 0
0
15.7.1.4 50 mm LM 0
0
15.7.1.5 63 mm LM 0
0
15.7.1.6 75 mm LM 0
0
15.7.1.7 110 mm LM 0
0
15.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 675/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
15.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0


0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
15.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 676/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
15.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
15.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 677/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

15.7.9.4 SF-B19-1 Set. 0


0
15.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
15.7.10.3 Chemical test kit No. 0
0
15.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
15.7.11.2.1 BT-B22-1 No. 0
0
15.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 678/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
15.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 679/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 680/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
15.8.2.1 20 mm. L.M 0
15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

0
15.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
15.8.3.1 Diam 100mm (4") L.M 0
15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 681/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 682/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
15.8.4.1 Diam 160mm (6") L.M 0
15.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
15.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 683/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
15.8.5.2 Diam 25mm L.M 0
15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 684/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

0
15.8.6.2 F-B18-02 Set. 0
0
15.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
15.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 685/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0
15.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary 0

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 686/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 687/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 688/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
16.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 689/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 0
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 690/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 691/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
16.30.2.1 Addressable smoke detector No. 0
16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 692/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 693/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 694/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 695/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 696/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

Service Building 2

ITEM DIV B14


DESCRIPTION UNIT
# # Amount

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0


0

DIV#16 Total cost of this section Carried Forward To Summary 0

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 697/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 698/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No. 41


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 699/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 700/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 701/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No.


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 702/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 703/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 15779

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 8138

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 704/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 66

3.1.2 Blinding, 50mm thick under slabs on grade m3 62

3.1.4 Blinding, 50mm thick under all types of tie beams m3 8

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 2

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 139

3.2.1.1 Foundations; (Raft , continous ) 139

3.2.2 Tie beams - Intermediate m3 67

3.2.3 Upper tie beams m3 45

3.2.4 Slabs on grade m3 250

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 705/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 185

3.2.6 Columns Below slab on grade m3 32

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 655

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3

3.3.2 Shear Walls , free standing walls above slab on Grade m3

3.3.3 Suspended solid slabs; including drop beams m3

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2

3.3.5 Stairs (steps, flights and landing) m3

3.3.6 Beams m3

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 706/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 1580

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 1275


3.4.2.1 Below slab on grade for basements -Horizontal 3600
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 250

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 707/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 708/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 709/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2


moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 710/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 711/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 712/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 0


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 713/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No.

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No.

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No.

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No.

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No.

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No.

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 714/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No.

8.3.3 METAL WINDOW Height 1 × 2 meter width No.

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No.


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No.

8.4.4.2 For wide 0.60 No.

8.4.4.3 For wide 0.90 No.

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 715/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2

9.1.2 Plastering to walls internal sides. m2

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 716/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2 2000

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0

9.2.12 L.G.B = LAMINATED GYPSUM m2


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 717/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No.

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2

9.3.32 Paint for walls m2

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2 1308

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2

9.4.3 CIRAMIC TILES (200*200*8)mm m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 718/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 719/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No.

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 2000
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 720/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M.

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 721/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM

Ladder

10.3.6 Supply and installation of galvanized iron ladder No.


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 722/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 723/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 724/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 725/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 726/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0

15.1.1.2 25 mm outside diameter pipe LM 0

15.1.1.3 32 mm outside diameter pipe LM 0

15.1.1.4 40 mm outside diameter pipe LM 0

15.1.1.5 50 mm outside diameter pipe LM 0

15.1.1.6 63 mm outside diameter pipe LM 0

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 727/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 0

15.1.2.3 EWH-3 (80 Liter ) No. 0

15.1.2.4 EWH-4 (100 Liter) No. 0

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 728/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 0

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 729/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 730/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 0

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 731/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 732/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 0

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 0

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 733/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 0

15.4.1.3 110 mm diameter pipe LM 0

15.4.1.4 160 mm diameter pipe LM 0

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 0

15.4.1.6 FD-110 mm outlet diameter No. 0

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 734/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 0

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 735/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 0

15.4.1.16 RD, 75mm outlet diameter No. 0

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 736/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 737/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 0

15.5.3.2.1.13 WDX-02 -1.5TR No. 0

15.5.3.2.1.14 WDX-03 -2TR No. 0

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 738/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 0

15.5.4.43.2 FAF-B-014 No. 0

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 0

15.5.4.88 EXF-B14-B-01 No. 0

15.5.4.89 EXF-B16-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 739/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 0

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 0

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 0

15.5.4.100 EXF-B17-2 NO 0

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 8

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 740/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 0

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 741/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 742/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 0

15.5.9.69 EAL-B14-01 No. 0

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 743/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 744/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 0

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 745/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 746/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 0

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 747/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 0

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 748/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 749/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 750/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 751/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 752/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 753/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 0

15.8.6.3 F-B18-03 Set. 0

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 754/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 755/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 0

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 0


16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 1
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 756/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0

16.24 Feeder Pillar 0

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 120
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 757/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 0


16.26.3 32A, SPN ,IP65 No. 11
16.26.4 32A, TPN ,IP65 No. 0

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 5
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 5
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 758/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 0


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 0


16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 69
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 10
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 759/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 760/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 0


16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 2
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 5
16.30.2.8 Control module (CM) No. 5
16.30.2.9 End of line resistane (E.O.L) No. 5

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 761/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 0


16.32.2 ref. M.D.C-2 No. 0

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 0


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 762/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 763/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 764/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 765/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PA

ITEM DIV B14


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 766/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 767/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No. 0
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 768/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 769/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 770/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 771/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 772/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 773/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 774/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 775/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 776/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 777/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 778/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 779/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 780/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 781/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 782/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 783/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 784/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 785/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 786/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 787/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 788/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 789/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 790/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 791/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 792/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 793/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 794/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 795/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 796/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 797/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 798/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 799/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 800/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 801/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
15.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
15.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 802/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
15.4.1.2 80 mm diameter pipe LM 0
0
15.4.1.3 110 mm diameter pipe LM 0
0
15.4.1.4 160 mm diameter pipe LM 0
0
15.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
15.4.1.5 FD-80 mm outlet diameter No. 0
0
15.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 803/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
15.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 804/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
15.4.1.15 RD, 110mm outlet diameter No. 0
0
15.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 805/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 806/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
15.5.3.2.1.12 WDX-01 - 1TR No. 0
0
15.5.3.2.1.13 WDX-02 -1.5TR No. 0
0
15.5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 807/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
15.5.4.43.1 FAF-B-013 No. 0
0
15.5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
15.5.4.55 Centrifugal in line fan 0
0
15.5.4.87 EXF-B13-B-01 No. 0
0
15.5.4.88 EXF-B14-B-01 No. 0
0
15.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 808/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
15.5.4.90 EXF-B17-01 No. 0
0
15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.99 EXF-B16-2 NO 0
0
15.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 809/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
15.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 810/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
15.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 811/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
15.5.9.68 EAL-B13-01 No. 0
0
15.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 812/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
15.7.1.1 25 mm LM 0
0
15.7.1.2 32 mm LM 0
0
15.7.1.3 40 mm LM 0
0
15.7.1.4 50 mm LM 0
0
15.7.1.5 63 mm LM 0
0
15.7.1.6 75 mm LM 0
0
15.7.1.7 110 mm LM 0
0
15.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 813/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
15.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0


0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
15.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 814/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
15.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
15.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 815/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

15.7.9.4 SF-B19-1 Set. 0


0
15.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
15.7.10.3 Chemical test kit No. 0
0
15.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
15.7.11.2.1 BT-B22-1 No. 0
0
15.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 816/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
15.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 817/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 818/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
15.8.2.1 20 mm. L.M 0
15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

0
15.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
15.8.3.1 Diam 100mm (4") L.M 0
15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 819/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 820/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
15.8.4.1 Diam 160mm (6") L.M 0
15.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
15.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 821/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
15.8.5.2 Diam 25mm L.M 0
15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 822/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

0
15.8.6.2 F-B18-02 Set. 0
0
15.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
15.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 823/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0
15.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary 0

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 824/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 825/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 826/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
16.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 827/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 0
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 828/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 829/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
16.30.2.1 Addressable smoke detector No. 0
16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 830/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 831/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 832/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 833/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 834/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH

CAR PARK

ITEM DIV B14P


DESCRIPTION UNIT
# # Amount

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0


0

DIV#16 Total cost of this section Carried Forward To Summary 0


0
G/Total Subaie Complex (Div 1~16) Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 835/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 836/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 837/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 838/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 839/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No.


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 840/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 841/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 270

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 105

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2 36

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 842/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 2

3.1.2 Blinding, 50mm thick under slabs on grade m3 1

3.1.4 Blinding, 50mm thick under all types of tie beams m3 1

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 2

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 4

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 6

3.2.3 Upper tie beams m3 6

3.2.4 Slabs on grade m3 5

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 843/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 1

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 2

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 9

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0

3.3.6 Beams m3 3

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 844/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 90

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2


3.4.2.1 Below slab on grade for basements -Horizontal 25
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 845/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2 201


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 846/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 847/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 36


moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM 29


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 848/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2 4
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 849/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 850/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 0


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 851/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No.

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No.

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 1

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 2

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No.

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No.

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 852/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No.

8.3.3 METAL WINDOW Height 1 × 2 meter width No.

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 2


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 1


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No. 2

8.4.4.2 For wide 0.60 No. 2

8.4.4.3 For wide 0.90 No. 1

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 853/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 172

9.1.2 Plastering to walls internal sides. m2 195

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 26


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2 30


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 854/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0

9.2.12 L.G.B = LAMINATED GYPSUM m2


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2 171


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 26

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 855/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2 2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 1

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2 26

9.3.32 Paint for walls m2 26

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2 195

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 25

9.4.3 CIRAMIC TILES (200*200*8)mm m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 856/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 857/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No. 2

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 4


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 26

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 858/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M.

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 859/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM

Ladder

10.3.6 Supply and installation of galvanized iron ladder No.


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 860/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 861/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 862/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 863/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 864/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 10

15.1.1.2 25 mm outside diameter pipe LM 10

15.1.1.3 32 mm outside diameter pipe LM 15

15.1.1.4 40 mm outside diameter pipe LM 0

15.1.1.5 50 mm outside diameter pipe LM 0

15.1.1.6 63 mm outside diameter pipe LM 0

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 865/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 1
15.1.1.16 Gate vlave Ø 40 mm 1
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 1

15.1.2.3 EWH-3 (80 Liter ) No. 0

15.1.2.4 EWH-4 (100 Liter) No. 0

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 866/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 0

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 867/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 868/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 0

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 869/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 1
15.3.1.2 WC-02 I 0

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 1
15.3.2.2 ( Lav-02 ) 0

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 870/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 0

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 0

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 3

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 871/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 0

15.4.1.3 110 mm diameter pipe LM 5

15.4.1.4 160 mm diameter pipe LM 10

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 1

15.4.1.6 FD-110 mm outlet diameter No. 0

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 872/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 0

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 873/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 1

15.4.1.16 RD, 75mm outlet diameter No. 0

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 1

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 874/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 1

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 1
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 875/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 1
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 0

15.5.3.2.1.13 WDX-02 -1.5TR No. 2

15.5.3.2.1.14 WDX-03 -2TR No. 0

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 876/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 0

15.5.4.43.2 FAF-B-014 No. 0

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 0

15.5.4.88 EXF-B14-B-01 No. 0

15.5.4.89 EXF-B16-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 877/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 0

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 1

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 0

15.5.4.100 EXF-B17-2 NO 0

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 878/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 5

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 879/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 880/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 0

15.5.9.69 EAL-B14-01 No. 0

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 881/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 882/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 0

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 883/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 884/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 0

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 885/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 0

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 886/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 887/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 888/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 889/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 890/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 891/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 0

15.8.6.3 F-B18-03 Set. 0

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 892/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 893/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 0

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 0


16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 894/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 1
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0

16.24 Feeder Pillar 0

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 230
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 895/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 0


16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 5


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 1
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 8
16.27.7 Spur outlet for electrical water heater No. 1
16.27.8 20A, double pole switch with neon. No. 1
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 896/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 7


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 0


16.29.4 Type F4 No. 1
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 1
16.29.8 Type F8 No. 1
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 1
16.29.16 Type F15 No. 3
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 897/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 1
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 898/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 0


16.30.2.2 Addressable smoke detector with sound base No. 3
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 1
16.30.2.8 Control module (CM) No. 1
16.30.2.9 End of line resistane (E.O.L) No. 1

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 899/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 1


16.32.2 ref. M.D.C-2 No. 0

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 0


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 900/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 1

16.35.2 RJ45 data socket outletr in floor mounted box No. 1

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 1


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 1

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 901/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 902/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 903/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISIO

MAIN G

ITEM DIV B15


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 904/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 905/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 906/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 907/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 908/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 909/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 910/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 911/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 912/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 913/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 914/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 915/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 916/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 917/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 918/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 919/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 920/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 921/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 922/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 923/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 924/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 925/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 926/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 927/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 928/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 929/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 930/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 931/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 932/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 933/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 934/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 935/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 936/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 937/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 938/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 939/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
15.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
15.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 940/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
15.4.1.2 80 mm diameter pipe LM 0
0
15.4.1.3 110 mm diameter pipe LM 0
0
15.4.1.4 160 mm diameter pipe LM 0
0
15.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
15.4.1.5 FD-80 mm outlet diameter No. 0
0
15.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 941/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
15.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 942/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
15.4.1.15 RD, 110mm outlet diameter No. 0
0
15.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 943/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 944/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
15.5.3.2.1.12 WDX-01 - 1TR No. 0
0
15.5.3.2.1.13 WDX-02 -1.5TR No. 0
0
15.5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 945/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
15.5.4.43.1 FAF-B-013 No. 0
0
15.5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
15.5.4.55 Centrifugal in line fan 0
0
15.5.4.87 EXF-B13-B-01 No. 0
0
15.5.4.88 EXF-B14-B-01 No. 0
0
15.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 946/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
15.5.4.90 EXF-B17-01 No. 0
0
15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.99 EXF-B16-2 NO 0
0
15.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 947/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
15.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 948/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
15.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 949/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
15.5.9.68 EAL-B13-01 No. 0
0
15.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 950/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
15.7.1.1 25 mm LM 0
0
15.7.1.2 32 mm LM 0
0
15.7.1.3 40 mm LM 0
0
15.7.1.4 50 mm LM 0
0
15.7.1.5 63 mm LM 0
0
15.7.1.6 75 mm LM 0
0
15.7.1.7 110 mm LM 0
0
15.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 951/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
15.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0


0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
15.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 952/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
15.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
15.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 953/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

15.7.9.4 SF-B19-1 Set. 0


0
15.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
15.7.10.3 Chemical test kit No. 0
0
15.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
15.7.11.2.1 BT-B22-1 No. 0
0
15.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 954/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
15.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 955/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 956/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
15.8.2.1 20 mm. L.M 0
15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

0
15.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
15.8.3.1 Diam 100mm (4") L.M 0
15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 957/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 958/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
15.8.4.1 Diam 160mm (6") L.M 0
15.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
15.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 959/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
15.8.5.2 Diam 25mm L.M 0
15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 960/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

0
15.8.6.2 F-B18-02 Set. 0
0
15.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
15.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 961/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0
15.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary 0

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 962/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 963/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 964/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
16.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 965/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 0
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 966/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 967/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
16.30.2.1 Addressable smoke detector No. 0
16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 968/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 969/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 970/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 971/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 972/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 /

MAIN GATE

ITEM DIV B15


DESCRIPTION UNIT
# # Amount

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0


0

DIV#16 Total cost of this section Carried Forward To Summary 0

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 973/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 974/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 975/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 976/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 977/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 1


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No. 2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 978/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 979/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 406

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 220

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2 148

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 980/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 7

3.1.2 Blinding, 50mm thick under slabs on grade m3 5

3.1.4 Blinding, 50mm thick under all types of tie beams m3 1

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 4

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 7

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 14

3.2.3 Upper tie beams m3 14

3.2.4 Slabs on grade m3 20

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 981/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 115

3.2.6 Columns Below slab on grade m3 2

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 4

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 25

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0

3.3.6 Beams m3 3

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 982/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 256

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 132


3.4.2.1 Below slab on grade for basements -Horizontal 96
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 983/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2 201


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2 86


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 984/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 985/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 109
moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM 54


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 986/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 987/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 988/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 0


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 989/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No.

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No.

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No.

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No.

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No.

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No.

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 3

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 990/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 1

8.3.3 METAL WINDOW Height 1 × 2 meter width No. 5

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No.


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No.

8.4.4.2 For wide 0.60 No.

8.4.4.3 For wide 0.90 No.

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 991/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2

9.1.2 Plastering to walls internal sides. m2 282

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 108


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2 108


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 992/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0

9.2.12 L.G.B = LAMINATED GYPSUM m2


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2 573


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 4

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 993/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No.

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2

9.3.32 Paint for walls m2 132

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2 282

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2

9.4.3 CIRAMIC TILES (200*200*8)mm m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 994/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 995/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No.

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2 114
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 996/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M.

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 997/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM

Ladder

10.3.6 Supply and installation of galvanized iron ladder No.


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 998/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 999/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1000/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1001/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1002/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0

15.1.1.2 25 mm outside diameter pipe LM 0

15.1.1.3 32 mm outside diameter pipe LM 0

15.1.1.4 40 mm outside diameter pipe LM 0

15.1.1.5 50 mm outside diameter pipe LM 0

15.1.1.6 63 mm outside diameter pipe LM 0

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1003/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 0

15.1.2.3 EWH-3 (80 Liter ) No. 0

15.1.2.4 EWH-4 (100 Liter) No. 0

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1004/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 0

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1005/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 4

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1006/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 0

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1007/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1008/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 0

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 0

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1009/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 10

15.4.1.3 110 mm diameter pipe LM 10

15.4.1.4 160 mm diameter pipe LM 0

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 0

15.4.1.6 FD-110 mm outlet diameter No. 0

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1010/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 0

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 4


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1011/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 0

15.4.1.16 RD, 75mm outlet diameter No. 2

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1012/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1013/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 0

15.5.3.2.1.13 WDX-02 -1.5TR No. 0

15.5.3.2.1.14 WDX-03 -2TR No. 0

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1014/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 0

15.5.4.43.2 FAF-B-014 No. 0

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 0

15.5.4.88 EXF-B14-B-01 No. 0

15.5.4.89 EXF-B16-01 No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1015/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 0

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 0

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 4

15.5.4.100 EXF-B17-2 NO 0

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1016/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 0

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1017/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1018/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 0

15.5.9.69 EAL-B14-01 No. 0

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 1
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1019/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1020/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 0

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1021/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1022/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 0

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1023/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 0

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1024/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1025/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1026/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1027/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1028/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1029/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 0

15.8.6.3 F-B18-03 Set. 0

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1030/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 1
16.21.3 Ref. ESMDB-S No. 1
16.21.4 Ref. LV-1 No. 1
16.21.5 Ref. ELV-1 No. 1
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1031/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 0

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 0


16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1032/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 1
16.23.11 Ref. EDB-B/C2 No. 0

16.24 Feeder Pillar 0

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 150


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 20
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1033/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 0


16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 4


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 2
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1034/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 17


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 0


16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 13
16.29.17 Type F15E No. 4
16.29.21 Type F19 No. 0
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1035/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1036/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 3


16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 1
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 1
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 1
16.30.2.8 Control module (CM) No. 1
16.30.2.9 End of line resistane (E.O.L) No. 1

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 1
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1037/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 0


16.32.2 ref. M.D.C-2 No. 0

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 0


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1038/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No.

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1039/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 2
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 1


16.37.2 150KVA Generator (G-2) No. 0

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1040/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 1
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 1

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1041/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCI

Electrical su

ITEM DIV B16


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1042/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1043/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1044/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1045/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1046/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1047/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1048/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1049/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1050/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1051/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1052/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1053/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1054/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1055/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1056/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1057/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1058/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1059/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1060/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1061/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1062/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1063/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1064/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1065/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1066/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1067/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1068/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1069/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1070/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1071/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1072/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1073/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1074/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1075/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1076/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1077/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
15.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
15.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1078/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
15.4.1.2 80 mm diameter pipe LM 0
0
15.4.1.3 110 mm diameter pipe LM 0
0
15.4.1.4 160 mm diameter pipe LM 0
0
15.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
15.4.1.5 FD-80 mm outlet diameter No. 0
0
15.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1079/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
15.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1080/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
15.4.1.15 RD, 110mm outlet diameter No. 0
0
15.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1081/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1082/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
15.5.3.2.1.12 WDX-01 - 1TR No. 0
0
15.5.3.2.1.13 WDX-02 -1.5TR No. 0
0
15.5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1083/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
15.5.4.43.1 FAF-B-013 No. 0
0
15.5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
15.5.4.55 Centrifugal in line fan 0
0
15.5.4.87 EXF-B13-B-01 No. 0
0
15.5.4.88 EXF-B14-B-01 No. 0
0
15.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1084/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
15.5.4.90 EXF-B17-01 No. 0
0
15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.99 EXF-B16-2 NO 0
0
15.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1085/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
15.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1086/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
15.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1087/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
15.5.9.68 EAL-B13-01 No. 0
0
15.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1088/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
15.7.1.1 25 mm LM 0
0
15.7.1.2 32 mm LM 0
0
15.7.1.3 40 mm LM 0
0
15.7.1.4 50 mm LM 0
0
15.7.1.5 63 mm LM 0
0
15.7.1.6 75 mm LM 0
0
15.7.1.7 110 mm LM 0
0
15.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1089/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
15.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0


0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
15.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1090/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
15.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
15.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1091/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

15.7.9.4 SF-B19-1 Set. 0


0
15.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
15.7.10.3 Chemical test kit No. 0
0
15.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
15.7.11.2.1 BT-B22-1 No. 0
0
15.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1092/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
15.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1093/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1094/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
15.8.2.1 20 mm. L.M 0
15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

0
15.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
15.8.3.1 Diam 100mm (4") L.M 0
15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1095/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1096/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
15.8.4.1 Diam 160mm (6") L.M 0
15.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
15.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1097/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
15.8.5.2 Diam 25mm L.M 0
15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1098/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

0
15.8.6.2 F-B18-02 Set. 0
0
15.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
15.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1099/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0
15.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary 0

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1100/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1101/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1102/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
16.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1103/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 0
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1104/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1105/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
16.30.2.1 Addressable smoke detector No. 0
16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1106/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1107/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No.

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1108/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1109/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1110/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 1

ITEM DIV B16


DESCRIPTION UNIT
# # Amount

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0


0

DIV#16 Total cost of this section Carried Forward To Summary 0

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1111/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1112/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1113/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1114/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1115/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 1


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No. 2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1116/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1117/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 418

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 218

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2 152

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1118/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 7

3.1.2 Blinding, 50mm thick under slabs on grade m3 5

3.1.4 Blinding, 50mm thick under all types of tie beams m3 1

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 4

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 7

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 14

3.2.3 Upper tie beams m3 14

3.2.4 Slabs on grade m3 20

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1119/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 115

3.2.6 Columns Below slab on grade m3 2

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 4

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 25

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0

3.3.6 Beams m3 3

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1120/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 256

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 132


3.4.2.1 Below slab on grade for basements -Horizontal 96
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1121/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2 179


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2 86


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1122/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1123/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 109
moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM 54


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1124/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1125/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1126/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 0


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1127/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No.

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No.

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No.

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No.

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No.

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No.

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 3

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1128/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 1

8.3.3 METAL WINDOW Height 1 × 2 meter width No. 5

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No.


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No.

8.4.4.2 For wide 0.60 No.

8.4.4.3 For wide 0.90 No.

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1129/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2

9.1.2 Plastering to walls internal sides. m2 282

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 108


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2 108


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1130/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0

9.2.12 L.G.B = LAMINATED GYPSUM m2


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2 573


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 4

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1131/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No.

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2

9.3.32 Paint for walls m2 132

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2 282

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2

9.4.3 CIRAMIC TILES (200*200*8)mm m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1132/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1133/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No.

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2 114
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1134/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M.

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1135/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM

Ladder

10.3.6 Supply and installation of galvanized iron ladder No.


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1136/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1137/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1138/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1139/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1140/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0

15.1.1.2 25 mm outside diameter pipe LM 0

15.1.1.3 32 mm outside diameter pipe LM 0

15.1.1.4 40 mm outside diameter pipe LM 0

15.1.1.5 50 mm outside diameter pipe LM 0

15.1.1.6 63 mm outside diameter pipe LM 0

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1141/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 0

15.1.2.3 EWH-3 (80 Liter ) No. 0

15.1.2.4 EWH-4 (100 Liter) No. 0

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1142/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 0

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1143/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 4

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1144/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 0

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1145/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1146/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 0

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 0

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1147/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 10

15.4.1.3 110 mm diameter pipe LM 10

15.4.1.4 160 mm diameter pipe LM 0

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 0

15.4.1.6 FD-110 mm outlet diameter No. 0

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1148/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 0

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 4


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1149/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 0

15.4.1.16 RD, 75mm outlet diameter No. 2

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1150/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1151/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 0

15.5.3.2.1.13 WDX-02 -1.5TR No. 0

15.5.3.2.1.14 WDX-03 -2TR No. 0

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1152/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 0

15.5.4.43.2 FAF-B-014 No. 0

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 0

15.5.4.88 EXF-B14-B-01 No. 0

15.5.4.89 EXF-B16-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1153/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 1

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 0

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 0

15.5.4.100 EXF-B17-2 NO 4

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1154/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 0

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1155/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1156/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 0

15.5.9.69 EAL-B14-01 No. 0

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 1
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1157/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1158/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 0

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1159/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1160/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 0

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1161/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 0

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1162/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1163/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1164/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1165/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1166/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1167/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 0

15.8.6.3 F-B18-03 Set. 0

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1168/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1169/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 1

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 0


16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1170/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 1

16.24 Feeder Pillar 0

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 150


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 20
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1171/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 0


16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 4


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 2
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1172/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 17


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 0


16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 13
16.29.17 Type F15E No. 4
16.29.21 Type F19 No. 0
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1173/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1174/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 3


16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 1
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 1
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 1
16.30.2.8 Control module (CM) No. 1
16.30.2.9 End of line resistane (E.O.L) No. 1

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 1
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1175/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 0


16.32.2 ref. M.D.C-2 No. 0

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 0


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1176/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No.

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1177/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 2
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 1

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1178/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 1
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 1
16.38.8 32A ATS No. 0

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1179/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical su

ITEM DIV B17


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1180/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1181/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1182/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1183/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1184/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1185/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1186/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1187/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1188/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1189/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1190/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1191/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1192/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1193/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1194/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1195/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1196/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1197/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1198/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1199/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1200/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1201/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1202/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1203/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1204/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1205/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1206/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1207/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1208/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1209/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1210/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1211/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1212/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1213/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1214/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1215/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
15.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
15.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1216/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
15.4.1.2 80 mm diameter pipe LM 0
0
15.4.1.3 110 mm diameter pipe LM 0
0
15.4.1.4 160 mm diameter pipe LM 0
0
15.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
15.4.1.5 FD-80 mm outlet diameter No. 0
0
15.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1217/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
15.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1218/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
15.4.1.15 RD, 110mm outlet diameter No. 0
0
15.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1219/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1220/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
15.5.3.2.1.12 WDX-01 - 1TR No. 0
0
15.5.3.2.1.13 WDX-02 -1.5TR No. 0
0
15.5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1221/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
15.5.4.43.1 FAF-B-013 No. 0
0
15.5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
15.5.4.55 Centrifugal in line fan 0
0
15.5.4.87 EXF-B13-B-01 No. 0
0
15.5.4.88 EXF-B14-B-01 No. 0
0
15.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1222/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
15.5.4.90 EXF-B17-01 No. 0
0
15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.99 EXF-B16-2 NO 0
0
15.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1223/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
15.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1224/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
15.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1225/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
15.5.9.68 EAL-B13-01 No. 0
0
15.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1226/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
15.7.1.1 25 mm LM 0
0
15.7.1.2 32 mm LM 0
0
15.7.1.3 40 mm LM 0
0
15.7.1.4 50 mm LM 0
0
15.7.1.5 63 mm LM 0
0
15.7.1.6 75 mm LM 0
0
15.7.1.7 110 mm LM 0
0
15.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1227/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
15.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0


0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
15.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1228/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
15.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
15.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1229/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

15.7.9.4 SF-B19-1 Set. 0


0
15.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
15.7.10.3 Chemical test kit No. 0
0
15.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
15.7.11.2.1 BT-B22-1 No. 0
0
15.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1230/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
15.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1231/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1232/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
15.8.2.1 20 mm. L.M 0
15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

0
15.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
15.8.3.1 Diam 100mm (4") L.M 0
15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1233/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1234/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
15.8.4.1 Diam 160mm (6") L.M 0
15.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
15.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1235/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
15.8.5.2 Diam 25mm L.M 0
15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1236/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

0
15.8.6.2 F-B18-02 Set. 0
0
15.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
15.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1237/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0
15.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary 0

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1238/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1239/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1240/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
16.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1241/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 0
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1242/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1243/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
16.30.2.1 Addressable smoke detector No. 0
16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1244/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1245/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1246/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1247/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1248/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

Electrical substation 2

ITEM DIV B17


DESCRIPTION UNIT
# # Amount

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0


0

DIV#16 Total cost of this section Carried Forward To Summary 0

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1249/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1250/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1251/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1252/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1253/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No.


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1254/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1255/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 1584

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 1039

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2 208

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1256/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 11

3.1.2 Blinding, 50mm thick under slabs on grade m3 9

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 38

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1257/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 285

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3

3.3.6 Beams m3

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1258/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 71

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2


3.4.2.1 Below slab on grade for basements -Horizontal
3.4.2.2 Water Tanks 1070
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 59

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1259/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1260/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1261/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2


moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1262/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1263/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1264/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 475


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1265/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No.

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No.

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No.

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No.

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No.

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No.

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1266/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No.

8.3.3 METAL WINDOW Height 1 × 2 meter width No.

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No.


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No.

8.4.4.2 For wide 0.60 No.

8.4.4.3 For wide 0.90 No.

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1267/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2

9.1.2 Plastering to walls internal sides. m2

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1268/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2

9.2.12 L.G.B = LAMINATED GYPSUM m2


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1269/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No.

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2

9.3.32 Paint for walls m2

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2

9.4.3 CIRAMIC TILES (200*200*8)mm m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1270/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1271/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No.

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1272/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M.

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1273/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM

Ladder

10.3.6 Supply and installation of galvanized iron ladder No.


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET 1

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 1
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1274/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1275/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1276/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1277/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1278/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0

15.1.1.2 25 mm outside diameter pipe LM 0

15.1.1.3 32 mm outside diameter pipe LM 0

15.1.1.4 40 mm outside diameter pipe LM 0

15.1.1.5 50 mm outside diameter pipe LM 0

15.1.1.6 63 mm outside diameter pipe LM 0

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1279/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 0

15.1.2.3 EWH-3 (80 Liter ) No. 0

15.1.2.4 EWH-4 (100 Liter) No. 0

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1280/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 0

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1281/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1282/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 0

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1283/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1284/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 0

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 0

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1285/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 0

15.4.1.3 110 mm diameter pipe LM 0

15.4.1.4 160 mm diameter pipe LM 0

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 0

15.4.1.6 FD-110 mm outlet diameter No. 0

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1286/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 0

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 1
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1287/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set 1

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 0

15.4.1.16 RD, 75mm outlet diameter No. 0

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1288/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1289/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 0

15.5.3.2.1.13 WDX-02 -1.5TR No. 0

15.5.3.2.1.14 WDX-03 -2TR No. 0

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1290/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 0

15.5.4.43.2 FAF-B-014 No. 0

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 0

15.5.4.88 EXF-B14-B-01 No. 0

15.5.4.89 EXF-B16-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1291/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 0

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 0

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 0

15.5.4.100 EXF-B17-2 NO 0

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1292/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 0

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1293/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1294/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 0

15.5.9.69 EAL-B14-01 No. 0

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1295/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1296/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 0

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1297/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1298/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 0

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1299/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 0

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1300/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1301/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1302/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1303/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 1

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1304/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1305/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 1

15.8.6.3 F-B18-03 Set. 1

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 2

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 1

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1306/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 1

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 1

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1307/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 0

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 0


16.22.2 Ref. MCC-R No. 1
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1308/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0

16.24 Feeder Pillar 0

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 85
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 85

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1309/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 0


16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 5
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1310/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 2


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 0


16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 2
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1311/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1312/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 1


16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1313/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 0


16.32.2 ref. M.D.C-2 No. 0

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 0


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1314/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1315/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1316/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1317/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W

ITEM DIV B18


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1318/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1319/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1320/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1321/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1322/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1323/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1324/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1325/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1326/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1327/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1328/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1329/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1330/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1331/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1332/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1333/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1334/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1335/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1336/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1337/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1338/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1339/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1340/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1341/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1342/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1343/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1344/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1345/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1346/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1347/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1348/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1349/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1350/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1351/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1352/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1353/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
15.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
15.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1354/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
15.4.1.2 80 mm diameter pipe LM 0
0
15.4.1.3 110 mm diameter pipe LM 0
0
15.4.1.4 160 mm diameter pipe LM 0
0
15.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
15.4.1.5 FD-80 mm outlet diameter No. 0
0
15.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1355/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
15.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1356/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
15.4.1.15 RD, 110mm outlet diameter No. 0
0
15.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1357/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1358/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
15.5.3.2.1.12 WDX-01 - 1TR No. 0
0
15.5.3.2.1.13 WDX-02 -1.5TR No. 0
0
15.5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1359/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
15.5.4.43.1 FAF-B-013 No. 0
0
15.5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
15.5.4.55 Centrifugal in line fan 0
0
15.5.4.87 EXF-B13-B-01 No. 0
0
15.5.4.88 EXF-B14-B-01 No. 0
0
15.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1360/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
15.5.4.90 EXF-B17-01 No. 0
0
15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.99 EXF-B16-2 NO 0
0
15.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1361/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
15.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1362/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
15.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1363/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
15.5.9.68 EAL-B13-01 No. 0
0
15.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1364/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
15.7.1.1 25 mm LM 0
0
15.7.1.2 32 mm LM 0
0
15.7.1.3 40 mm LM 0
0
15.7.1.4 50 mm LM 0
0
15.7.1.5 63 mm LM 0
0
15.7.1.6 75 mm LM 0
0
15.7.1.7 110 mm LM 0
0
15.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1365/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
15.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0


0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
15.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1366/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
15.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
15.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1367/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

15.7.9.4 SF-B19-1 Set. 0


0
15.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
15.7.10.3 Chemical test kit No. 0
0
15.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
15.7.11.2.1 BT-B22-1 No. 0
0
15.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1368/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
15.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1369/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1370/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
15.8.2.1 20 mm. L.M 0
15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

0
15.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
15.8.3.1 Diam 100mm (4") L.M 0
15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1371/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1372/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
15.8.4.1 Diam 160mm (6") L.M 0
15.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
15.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1373/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
15.8.5.2 Diam 25mm L.M 0
15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1374/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

0
15.8.6.2 F-B18-02 Set. 0
0
15.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
15.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1375/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0
15.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary 0

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1376/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1377/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1378/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
16.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1379/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 0
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1380/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1381/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
16.30.2.1 Addressable smoke detector No. 0
16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1382/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1383/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1384/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1385/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1386/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G MAIN W/TANK

ITEM DIV B18


DESCRIPTION UNIT
# # Amount

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0


0

DIV#16 Total cost of this section Carried Forward To Summary 0

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1387/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1388/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1389/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1390/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1391/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No.


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1392/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1393/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 293

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 162

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2 25

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1394/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 3

3.1.2 Blinding, 50mm thick under slabs on grade m3 1

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 9

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1395/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 52

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3

3.3.6 Beams m3

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1396/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 15

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2


3.4.2.1 Below slab on grade for basements -Horizontal
3.4.2.2 Water Tanks 410
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 20

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1397/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1398/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1399/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2


moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1400/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1401/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1402/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 0


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1403/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No.

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No.

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No.

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No.

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No.

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No.

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1404/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No.

8.3.3 METAL WINDOW Height 1 × 2 meter width No.

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No.

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No.


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No.

8.4.4.2 For wide 0.60 No.

8.4.4.3 For wide 0.90 No.

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1405/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2

9.1.2 Plastering to walls internal sides. m2

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1406/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2

9.2.12 L.G.B = LAMINATED GYPSUM m2


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1407/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No.

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2

9.3.32 Paint for walls m2

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2

9.4.3 CIRAMIC TILES (200*200*8)mm m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1408/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1409/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No.

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2 25
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1410/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M.

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1411/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM

Ladder

10.3.6 Supply and installation of galvanized iron ladder No.


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET 1

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 1
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1412/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1413/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1414/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1415/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1416/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0

15.1.1.2 25 mm outside diameter pipe LM 0

15.1.1.3 32 mm outside diameter pipe LM 0

15.1.1.4 40 mm outside diameter pipe LM 0

15.1.1.5 50 mm outside diameter pipe LM 0

15.1.1.6 63 mm outside diameter pipe LM 0

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1417/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 0

15.1.2.3 EWH-3 (80 Liter ) No. 0

15.1.2.4 EWH-4 (100 Liter) No. 0

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1418/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 0

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1419/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1420/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 0

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1421/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1422/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 0

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 0

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1423/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 0

15.4.1.3 110 mm diameter pipe LM 0

15.4.1.4 160 mm diameter pipe LM 0

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 0

15.4.1.6 FD-110 mm outlet diameter No. 0

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1424/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 0

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 1
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1425/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 0

15.4.1.16 RD, 75mm outlet diameter No. 0

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1426/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1427/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 0

15.5.3.2.1.13 WDX-02 -1.5TR No. 0

15.5.3.2.1.14 WDX-03 -2TR No. 0

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1428/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 0

15.5.4.43.2 FAF-B-014 No. 0

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 0

15.5.4.88 EXF-B14-B-01 No. 0

15.5.4.89 EXF-B16-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1429/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 0

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 1

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 0

15.5.4.100 EXF-B17-2 NO 0

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1430/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 0

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1431/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1432/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 0

15.5.9.69 EAL-B14-01 No. 0

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1433/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1434/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 2

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1435/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1436/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 1

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1437/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 1

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1438/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1439/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1440/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1441/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1442/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1443/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 0

15.8.6.3 F-B18-03 Set. 0

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1444/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1445/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 0

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 0


16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 1
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1446/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0

16.24 Feeder Pillar 0

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 35
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1447/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 0


16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 3
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1448/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 2


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 0


16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 2
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1449/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1450/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 1


16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1451/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 0


16.32.2 ref. M.D.C-2 No. 0

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 0


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1452/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1453/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1454/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1455/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
DIVISION # 1~16 / ALL DISCIPLINES

U/G PUMP
SURGE T

ITEM DIV B19


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1456/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1457/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1458/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1459/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1460/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1461/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1462/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1463/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1464/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1465/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1466/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1467/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1468/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1469/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1470/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1471/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1472/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1473/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1474/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1475/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1476/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1477/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1478/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1479/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1480/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1481/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1482/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1483/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1484/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1485/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1486/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1487/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1488/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run 0
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0
0
0
15.2 FIRE FIGHTING SYSTEM 0
All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications 0

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to 0
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1489/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0


0
Supply, install, test and commission fire blanket, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as 0
per owner instructions"

15.2.3 Fire blanket No. 0


0
15.3 PLUMBING FIXTURE APPLIANCES 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1490/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from 0
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

0
Water Closet No. 0
Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and 0
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0
0
Lavatories No. 0
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge 0
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

0
15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0
0
kitchen sink No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1491/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all 0
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

0
15.3.6.2 Double bowl (KS-02) No. 0
0
Shower Hand mixer 0
Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
0
per owner representative and consultant.)

0
15.3.9.1 SH-01 (sypply and install) No. 0
0
0
15.4 STORMWATER AND DRAINAGE SYSTEM 0
0
15.4.1 Pipework 0
0
Supply, install, test and commission UPVC pipes
installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories, 0
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.1 50 mm diameter pipe LM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1492/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
15.4.1.2 80 mm diameter pipe LM 0
0
15.4.1.3 110 mm diameter pipe LM 0
0
15.4.1.4 160 mm diameter pipe LM 0
0
15.4.1.4.1 200 mm diameter pipe 0
0
Floor Drain 0
0
Supply Floor Traps, trapped gulley type, ABS or UPVC
body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
0
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

0
15.4.1.5 FD-80 mm outlet diameter No. 0
0
15.4.1.6 FD-110 mm outlet diameter No. 0
0
Floor Cleanout 0
0
Supply Floor cleanout stainless steel cover and frame
installed connected and tested complete with
accessories all as specified and shown on drawings.. 0
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"
0
15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1493/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
15.4.1.8 WCO- 110mm No. 0
0
Trench Drain 0
0
Supply Trench drain, stainless steel gutter & grating
for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room 0
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

0
Submersible Pumps 0
0
Supply, install, test and commission Duplex
submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1494/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator 0
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain 0
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete 0
with accessories all as specified and shown on drawing.

0
15.4.1.15 RD, 110mm outlet diameter No. 0
0
15.4.1.16 RD, 75mm outlet diameter No. 0
0
Down spout 0
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
0
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0


0
Roof Vent Cap 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1495/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST, 0
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 0
0
15.5 HVAC SYSTEM 0
BUILDER'S WORK RELATED TO MECHANICAL
0
WORKS
0
The contractor shall provide builder's work required by
the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 0
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

0
LABELING AND IDENTIFYING 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1496/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 0
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications
0
15.5.3 AIR CONDITIONERS UNITS 0
0
0
Supply, install test & commission A/C units,Inverter
model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

0
0
Split Wall mounted Type - For service Drivers , 0
Maid stores .. 0
15.5.3.2.1.12 WDX-01 - 1TR No. 0
0
15.5.3.2.1.13 WDX-02 -1.5TR No. 0
0
15.5.3.2.1.14 WDX-03 -2TR No. 0
0
15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1497/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
Supply, install, connect, test and commission,
Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required 0
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

0
15.5.4.43.1 FAF-B-013 No. 0
0
15.5.4.43.2 FAF-B-014 No. 0
0
0
Supply, install test & commission exhaust fan unit,
roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back 0
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

0
15.5.4.55 Centrifugal in line fan 0
0
15.5.4.87 EXF-B13-B-01 No. 0
0
15.5.4.88 EXF-B14-B-01 No. 0
0
15.5.4.89 EXF-B16-01 No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1498/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
15.5.4.90 EXF-B17-01 No. 0
0
15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0
0
Supply, install, connect, test and commission, Cassette
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.91 CEX-01 No. 0
0
Supply, install, connect, test and commission, Window
type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans , 0
greenheck, ASEM or equivalent as per owner
instructions"
0
15.5.4.99 EXF-B16-2 NO 0
0
15.5.4.100 EXF-B17-2 NO 0
0
Supply, install, test and commission centrifugal in line
Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all 0
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0


0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1499/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

15.5.5 Condensate Pipework 0


0
Supply UPVC pressure pipes to BS 3505 class E solvent
cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
0
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

0
15.5.5.1 25 mm outside diameter pipe LM 0
0
15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1500/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

0
Supply, install, connect, test and commission black
steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.
0

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

0
Supply, install, test and commission powder coated
aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for 0
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

0
15.5.9.19 EG-01 No. 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1501/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved 0
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"
0
0
15.5.9.68 EAL-B13-01 No. 0
0
15.5.9.69 EAL-B14-01 No. 0
0
0
15.6.9 Diesel Tank 0
Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed
0

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1502/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
15.7.1 PVC Pipes 0
0
Supply PVC pressure pipes for fountains and swimming
pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints, 0
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

0
15.7.1.1 25 mm LM 0
0
15.7.1.2 32 mm LM 0
0
15.7.1.3 40 mm LM 0
0
15.7.1.4 50 mm LM 0
0
15.7.1.5 63 mm LM 0
0
15.7.1.6 75 mm LM 0
0
15.7.1.7 110 mm LM 0
0
15.7.1.8 160mm LM 0
0
15.7.2 Swimming pool pump 0
0
Supply, install, test & commission filter pumps,
complete with built-in basket strainer, 2900 RPM 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1503/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
15.7.2.7 FP-B19-1 No. 0
0
0
15.7.3 Inlet Fitting 0
0
Supply ABS wall mounted , adjustable jet, threaded
connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as 0
specified and shown on drawings

0
15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0


0
ABS vacuum , threaded connection, installed,
connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on 0
drawings

0
15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0
0
15.7.5 Main Drain 0
0
Supply ABS frame and grate, installed, connected and
tested complete with accessories, all as specified and 0
shown on drawings
0
15.7.5.1 Main drain MD No. 0
0
15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1504/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
Supply and install overflow trench plastic gutter and
grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as 0
spesified and shown on drawings.

0
15.7.6.1 Overflow Trench LM 0
0
15.7.7 Outlet Fitting 0
0
Supply Chrome plated , 82 mm diameter, threaded
connection, installed, connected and tested complete
0
including PVC no-leak flange and accessories, all as
specified and shown on drawings
0
15.7.7.1 Outlet fitting 75mm diameter No. 0
0
15.7.8 Fill Fitting 0
0
Initial fill fittings, installed and tested, complete with
accessories, all as specified and shown on drawings. 0

0
15.7.8.1 Initial fill fittings, 20 mm diameter No. 0
0
15.7.9 Pool Sand Filter 0
0
Supply and install pool sand filter, FRP material
construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure 0
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1505/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

15.7.9.4 SF-B19-1 Set. 0


0
15.7.10 Chemical Feeding and Control Accessories 0
0
Supply, install and test Hypochlorination automatic
dosing feeder with polyethylene tank and accessories 0

0
15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0
0
Supply, install and test PH / Chlorine level controller
with wiring and electric connections 0

0
15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0
0
15.7.10.3 Chemical test kit No. 0
0
15.7.11 Balance Tank 0
0
Supply Water tank, 4-layers polyethylene construction,
vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve, 0
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

0
Capacity (6) m3 0
15.7.11.2.1 BT-B22-1 No. 0
0
15.7.12 Electrical Heat Exchanger 0
0
Supply Stainless steel pool heat exchanger, installed 0
and tested complete with Digital Thermostat, valves, 0
control valve & all related works as specified and 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1506/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
shown on drawings. 0
0
Pool Heat Exchanger H.X 0
15.7.12.1 P- HE-01 (21 KW) No. 0
0
15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1507/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
SITE WORKS 0
15.8.1 MANHOLES AND STRUCTURES 0
0
Supply, install test & commision Concrete
construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"
0
15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0
15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0
0
Supply, install test & commision Concrete
construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST, 0
RABITAL, MAZAYA or equivalent as per owner
instructions"

0
15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0
15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0
0
0
15.8.2 SITE WATER DISTRIBUTION 0
0
Supply, install test & commision HDPE, pipe for water
pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation 0
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1508/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
15.8.2.1 20 mm. L.M 0
15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0
0
Supply, install, test and commission water flow meters
15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

0
Supply, install, test and commission water valve
chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

0
15.8.2.10 Supply, install test & commision Hose Bibb No. 0
0
15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0
0
Supply, install test & commission Seamless black steel
pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all 0
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

0
15.8.3.1 Diam 100mm (4") L.M 0
15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1509/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
FIRE FIGHTING SYSTEM AND EQUIPMENT 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1510/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
Supply, install, test and commission fire hydrant with
hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

0
Supply, install, test and commission electrical fire
fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH, 0
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"
0
15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0
0
15.8.4 SEWER & STORM PIPING 0
0
Supply, install test & commision UPVC PN16 for rain
& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
0
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

0
15.8.4.1 Diam 160mm (6") L.M 0
15.8.4.2 Diam 200mm (8") L.M 0
0
Supply Trench drain, cast iron gutter & grating for
site area, installed, connected, and tested complete
including frame, concrete work, waterproofing, 0
earthwork and accessories, all as specified and shown
on drawings.

0
15.8.4.3 1000mm X300mm No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1511/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

LPG PIPING AND TANK 0


15.8.5 0
0
Supply, install test & commission, LPG tank as shown
in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters 0
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0


0
Supply, install test & commision, Fuel pipes to BS-
1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's . 0
INTERPIPE, SPS, or equivalent as per owner
instructions"

0
15.8.5.2 Diam 25mm L.M 0
15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0
0
Supply, install, test and commissionLPG filling cabinet
complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .
0
15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0
0
Supply, install, test and commission Automatic Sand
filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET. 0
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.
0
15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1512/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

0
15.8.6.2 F-B18-02 Set. 0
0
15.8.6.3 F-B18-03 Set. 0

0
Supply, installation ,testing and commissioning of
"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and 0
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

0
15.8.6.4 SOF-B18-01 Set. 0
0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all 0
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0


0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's. 0
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

0
15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1513/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0
15.8.6.8 IRRP-B18-02 Set. 0
0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET. 0
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0


0
0
DIV#15 Total cost of this section Carried Forward To Summary 0

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1514/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
16.21.7 Ref. ELV-2 No. 0
0
16.22 Motor Control Center 0
0
Section 16443 Motor Control Centres 0
0
Supply, install, test and commission Motor control center 0
including all necessary MCCB's, MCB, bus bars, casing, 0
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor, 0
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed 0
accessories as shown on the drawings. 0
0
0
16.22.1 Ref. MCC-L No. 0
16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0
0
16.23 Distribution Boards 0
0
Section 16440 Switchboards - 600 volts and below 0
16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1515/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0
0
16.24 Feeder Pillar 0
0
Section 16440 Switchboards - 600 volts and below 0
16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0
0
16.25 Feeders 0
0
Section 16122 600 - Volt Cable 0

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable 0
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

0
16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0
16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 0
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1516/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
16.26 A Isolating switches 0
Supply, install, test and commission Isolating switch 0
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment , 0
PedestaL.S (where needed ) ,and all needed accessories 0
and as shown on the drawings .
0
16.26.2 25A, TPN ,IP65 No. 0
16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0
0
0
16.27 Power Socket Outlets 0
0
Sections 16020, 16120, 16130 ,16140 0
0
Supply, install, test and commission Socket outlet
including all necessary PVC conduits, wires, cables, pull 0
and junctions boxes , floor boxes (where needed as per 0
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as 0
shown on the drawings (legrand / MK) or equivlent.
0
0
16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 0
in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 0
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 0
16.27.7 Spur outlet for electrical water heater No. 0
16.27.8 20A, double pole switch with neon. No. 0
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0
0
16.28 Lighting System 0
Sections 16010, 16120 ,16510 ,16530 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1517/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
0

Supply, install, test and commission Lighting points 0


including switches with all necessary conduits, 0
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed 0
accessories as shown on the drawings. 0
0
16.28.1 Internal Lighting points No. 0
16.28.2 External Lighting points No. 0
0
16.29 Lighting Fixtures 0
0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal 0
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

0
16.29.1 Type F1 No. 0
16.29.4 Type F4 No. 0
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 0
16.29.8 Type F8 No. 0
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 0
16.29.16 Type F15 No. 0
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1518/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0
0
16.3 Fire Alarm Installation 0
0
Sections 16710 Fire Alarm 0

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 0
16.30.1.2 No.
loop)
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1519/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

0
16.30.2.1 Addressable smoke detector No. 0
16.30.2.2 Addressable smoke detector with sound base No. 0
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 0
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 0
16.30.2.8 Control module (CM) No. 0
16.30.2.9 End of line resistane (E.O.L) No. 0
0
16.31 EARTHING SYSTEM 0
0
Sections 16125 EARTHING 0
16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1520/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

0
16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

0
16.32.1 ref. M.D.C-1 No. 0
16.32.2 ref. M.D.C-2 No. 0
0
16.33 CCTV SYSTEM 0
0
Sections 16690 IP network components 0
0

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and 0
terminations, and all needed accessories as specified and
as shown on the drawings.

0
16.33.1 Fixed INDOOR IP-camera No. 0
16.33.2 Weather proof Fixed IP-camera , pole mounted No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1521/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

0
16.35 LOW CURRENT SYSTEMS 0
0
Sections 16110, 16120, 16130, 16140, 16690 IP network 0
components 0
0
Supply, install, test and commission Telephone / Data / 0
IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals, 0
cable trunks and baskets ,conduits, pull and junction 0
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed 0
accessories as shown on the drawings by legraned or
equivalent . 0
0

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 0

16.35.2 RJ45 data socket outletr in floor mounted box No. 0

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 0

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1522/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

0
16.36 Transformer (coordinated item with SCECO) 0
0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

0
16.37 GENERATOR ASSEMBLIES
SECTION 16620, 16450 0
0
DIESEL ENGINE DRIVEN GENERATING SET
0
0
Supply, install, test and commission, 400V, 60Hz
1500rpm standby diesel power Generator set , including 0
control panel, battery starting , cooling , fuel,diesel 0
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as 0
specified and as shown on the drawings
0

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0
0
4-Pole automatic transfer switch (ATS) , complete with
control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

0
16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1523/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0
0
16.39 Conduits 0
0
Section 16010, 16020 , 16110
0

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage 0
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

0
900mmx900mmx800mm concrete manhole,
16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1524/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISION # 1~16 / ALL DISCIPLINES

U/G PUMP ROOM &


SURGE TANK

ITEM DIV B19


DESCRIPTION UNIT
# # Amount

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0


0

DIV#16 Total cost of this section Carried Forward To Summary 0

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1525/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS

DIV#1 Total cost of this section Carried Forward To Summary

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY

Complete the following (Architectural / Partial) items


as specified in the drawings & specifications. i.e.
02213, 02620, 02625, 02630, 02641, 02811

2.1 External Fence Wall

Supply and apply external textutre paint on concrete ,


2.1.1 m2
sample to be approved by celint

Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1526/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking

Car Wheel Stopper

2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.


car wheel stopper complete with all the
required components for stopper cars .

Football Field / Playground


Excluded- At this stage
2.1.6 Preparation of football ground, including leveling, No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1527/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
agriculture soil & Bermuda gross etc. Size 18×26 meter
(For Mr. Ibrahim Group)

2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No.

2.2 LANDSCAPE:
Excluded- At this stage
Supply and for complete with all the required
components to complete the work including
preparation of underneath layer and as specified
in drawings and specifications.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1528/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Green Area
Excluded- At this stage
2.2.1 1.25 meters wide Green Belt all around the main LM
swimming pool in the center of the buildings
connecting to 2.00 meters wide 4 Nos. Gates.

2.2.2 Trees with 100mm thick layer of clean loose m2


gravel as dust protection (and/or) as approved.

2.2.3 Ditto but with out gravel beside the fence LM

Interlock
Excluded- At this stage
2.2.4 80mm thick Yellow color CONCRETE PAVING m2
BLOCKS (AS OWNER SELECTION)

2.2.5 Ditto but, Brown color m2

Stone Walkways
Excluded- At this stage
2.2.6 Supply and installation of stone slabs, including m2
underneath preparations.

Villas Private Entrances


Excluded- At this stage
2.2.7 Private entrances for villas between car ways m2
and buildings as per drawing.

Link Between Villas


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1529/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Walkways links between the villas and includes
work finishes and paints flowers of different
levels according to the design

2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM

2.2.9 Villa Mr. Adel and Majid LM

2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM

2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM

2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM

2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM

2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM

Void Open Spaces (Between Buildings)


Excluded- At this stage
2.2.15 General preparations as per design levels for open m2
void area spaces between buildings & hard/green
landscapes to complete ready for any storm water
disposal.

Concrete Ramp

2.2.16 RAMP concrete thickness of 15 cm epoxy paint No.


long 2 m wide 3 meter at SCECO Room

2.2.17 Ditto but wide 2.3 No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1530/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1531/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
2.3 EARTHWORKS

Excavation & backfilling

Excavation in any kind of soil, rock, etc, starting at


existing ground levels down to bottom of foundations,
complete as per drawings.

2.3.1 Site leveling and foundation excavations m3 270

Selected imported engineering compacted fill to 95% of


modified proctor test, in layers not exceeding 250mm
each, complete

2.3.2 Up to levels and around & above foundations. m3 105

Crushed aggregate base course, compacted to 100%


modified AASHTO density CBR ≥ 80%

2.3.3 250mm thick under slabs on grade m2 36

2.4 ANTI TERMITE


Refer to spesification # 2285
2.4.1 Termite control treatment for all vertical and L.S 1
horizontal areas complete in accordance with
specifications.

DIV#2 Total cost of this section Carried Forward To Summary

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1532/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 2

3.1.2 Blinding, 50mm thick under slabs on grade m3 1

3.1.4 Blinding, 50mm thick under all types of tie beams m3 1

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 2

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 4

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 7

3.2.3 Upper tie beams m3 7

3.2.4 Slabs on grade m3 5

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1533/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 3

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 7

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 9

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3

3.3.6 Beams m3 1

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1534/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 103

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2


3.4.2.1 Below slab on grade for basements -Horizontal 25
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr

DIV#3 Total cost of this section Carried Forward To Summary

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1535/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls

4.2.2 300 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.3 250 mm thick (CMU) block masoNo.y works to m2


internal / partition walls / Parapet

4.2.4 200 mm thick (CMU) block masoNo.y works to m2 201


internal / partition walls / Parapet

4.2.5 150 mm thick (CMU) block masoNo.y works to m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1536/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
internal / partition walLS

4.2.6 100 mm thick (CMU) block masoNo.y works to m2


internal /partition walLS

4.3 Forming of Arch. Shape

4.3.1 Construction of block masonry works, to get m3


shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary

5 DIV#5 METAL WORKS LS

NA

DIV#5 Total cost of this section Carried Forward To Summary

6 DIV#6 WOOD & PLASTIC LS


NA

DIV#6 Total cost of this section Carried Forward To Summary

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1537/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 36


moisture protection and waterproofing consisting
of 40 mm smooth finish sloping screed over roof
slab, 3+3 modified bituminous waterproofing
membrane over primer, including 50mm thick
extruded polystyrene boards 35KG/m3, separation
layer 140KG/m2 and finish Cement tiles 300x300x30mm to
horizontal and vertical areas as shown and
specified in the drawings and specifications.

7.1.2 Ditto, but without roof boards along parapet LM 29


vertical up-stand 150 mm above from roof finish
level, including aluminum flashing 100 mm wide
and 1.5 mm thick at termination level as specified
in the drawings and specifications.

Wet Areas (Bath Rooms & Kitchens)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1538/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
7.1.3 Supply, install and test of the liquid applied m2 4
polyurethane waterproofing type (black P.U.) to be
applied in two (2) layers 1.5 liters/m2 over the
entire flat areas including vertical and horizontal
penetrations, drains and to be self-terminated at
minimum 100 mm above the floor finish level
including separation layer, screed protection (or)
equivalent and all necessary components to
complete ready facility as specified.

Planter Boxes & Green area


Excluded- At this stage
7.1.4 Construction of planter boxes at basement,
LS
including agriculture soil, plants and waterproofing
if required, Finishing with the outside marble or
ceramic ( choose Owner ) complete ready in all
respect, Size as follows: Area : 2.00 m2

7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No.

7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No.

7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No.

7.1.8 Ditto, but Size is 1300×900×400 mm in height . No.

7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No.

7.1.10 Ditto, but agriculture soil, plants and waterproofing No.


only with out Construction in family sitting Size is :
1600 mm2 .

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1539/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

7.1.11 GARDEN Inside the building m2

7.1.12 Green area out side the building beside the ramp No.
round shape radius1.65 meter

7.1.13 Green area in side the building with gravel m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1540/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

7.1.14 Green area out side the building m2

7.1.15 Green area out side the building four levels m2


from +3.5 to +5.4
Swimming Pool & Water Tanks

7.1.3 Supply, install and test of the liquid applied m2 0


Cement based proofing
applied in two (2) layers 1.5 liters/m2 over the
entire areas including vertical and horizontal
penetrations, drains and to be self-terminated
equivalent and all necessary components to
complete ready facility as specified.

DIV#7 Total cost of this section Carried Forward To Summary

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1541/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No.

8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No.

8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 1

8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 2

8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No.

8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No.

8.3 SCECO Room

Selected metal doors of the Saudi Electricity


Company with ventilation openings .
complete with Metal Paint finsh as per Sceco Standard

8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1542/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
8.3.2 Ditto but Size : 2.2× 1.5 meter No.

8.3.3 METAL WINDOW Height 1 × 2 meter width No.

8.4 Main Gate & Windows @ Fence Wall

8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No.


wide 5 meter

8.4.2 Double for sub gate wide 4 meter No. 2

8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 1


Size 0.9 × 2.6 meter

8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY


GRILLE
8.4.4.1 For wide 1.35 No. 2

8.4.4.2 For wide 0.60 No. 2

8.4.4.3 For wide 0.90 No. 1

DIV#8 Total cost of this section Carried Forward To Summary

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1543/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 172

9.1.2 Plastering to walls internal sides. m2 195

9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 26


(Painted spaces only)

9.2 Ceilings Finishes

Supply and installation of ceiling finishing with


all the necessary materials and components as
indicated in the drawings and specifications:-

Inside the building

9.2.1 Paint to plastered ceiling surfaces underneath of m2 30


R.C slab. (color as to be approved by the client )

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1544/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
9.2.2 Paint on Concrete m2

9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0

9.2.12 L.G.B = LAMINATED GYPSUM m2


Moisture resistant gypsum board with paint

9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2


Kitchens

Wall Finishes

Supply and installation of wall finishing with all the


necessary materials and components as
indicated in the drawings and specifications:-

NOTE :-
Upper roof penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.3 External Walls Surfaces

9.3.1 Exterior finishes of the type EF-01 CEMENT m2 171


RENDERING item includes all installation,
protection and accessories and the necessary
accessories to terminate the business, according
to what is shown on the drawings. installation and
protection work with what is shown on drawings.

9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 26

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1545/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
item includes all installation, protection and
accessories and the necessary accessories to
terminate the business, according to what is
shown on the drawings. installation and protection
work with what is shown on drawings.

9.3.3 Ditto but, the upper parts of the windows. m2 2

9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 1

9.3.21 Exterior finishes of the type EF-07C GRC ARC m2

GRC Panels

9.3.30 Paint for parapet from internal only m2 26

9.3.32 Paint for walls m2 26

NOTE :-
Upper roof no penthouses, computed as internal
finishing type EF-01 Cement Rendering.

9.4 Internal Walls Surfaces

9.4.1 Paint the interior walls m2 195

9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 25

9.4.3 CIRAMIC TILES (200*200*8)mm m2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1546/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

9.5 Glass Walls


Excluded- At this stage
Supply & installation of structural glazing system,
as specified in the drawings as per manufacturer
standard and in accordance with specifications.
Price to includes all necessary accessories,
caulking, sealant, grouting & other needed works
to complete ready in all respect. The contractor
shall submit sectional samples of the system
showing all details for client and engineer approval
for both aluminum & glass. Structural Glazing with
tag/Size as follows:

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1547/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

9.5.15 Glass wall in the main gate H 1.2 No. 2

9.6 Floor Finishes

Supply and installation of floor finishing with


skirting and all the necessary materials and
components as indicated in the drawings and
specifications:-

9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 4


(300*300*8)mm

9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 26

9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2

100 mm thk. TROWLLED CONCRETE WITH EPOXY


9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2
ROAD MARKS

DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150


9.6.12 m2
MM HIGHT

9.7 Stairs Finishes


Only for service staires
Saudi Binanco Granite - THREAD 30mm
THICK)/RISER 20MM THICK price to include

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1548/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
grooves for non-slip material and nose forming as
9.7.1 for service build. staircase L.M.

DIV#9 Total cost of this section Carried Forward To Summary

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to


be melamine laminated, complete with shelves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1549/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
and dish rack, composing of double bowl
stainless steel sink, overhead cabinet with all the
necessary fittings and accessories as shown &
specified in the drawings. Wall length back to
back L.M

10.3 MISCELLANEOUS

Internal Stair

10.3.3 Handrail to external stairs LM

10.3.4 Handrail to internal stairs LM

Ladder

10.3.6 Supply and installation of galvanized iron ladder No.


Height 3.00 meters.complete with paint finsh

10.3.7 PVC COATED STEEL LADDER RUNGS


To suit water tank - HIGHT 3.3 : 3.72 SET

Manhole Covers

10.3.7 Stainleass steel frame with stone cover to match Adjacent are No.
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1550/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

DIV#10 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1551/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
11 DIV#11 EQUIPMENTS LS
NA

DIV#11 Total cost of this section Carried Forward To Summary

12 DIV#12 FURNITURE LS
NA

DIV#12 Total cost of this section Carried Forward To Summary

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1552/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No.

13.1.35 Type-35 Size : 14.45 × 2.4 meter No.

13.3 SWIMMING POOL FINISH


Excluded- At this stage
Finished floors and walls of the swimming pool in
addition to all kinds of waterproofing with all
accessories .

13.3.3 WALL FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner
LEVEL -1.8 M

13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2


according to the choice of the owner

DIV#13 Total cost of this section Carried Forward To Summary

14 DIV#14 CONVEYING SYSTEM

NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1553/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

DIV#14 Total cost of this section Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1554/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 10

15.1.1.2 25 mm outside diameter pipe LM 10

15.1.1.3 32 mm outside diameter pipe LM 15

15.1.1.4 40 mm outside diameter pipe LM 0

15.1.1.5 50 mm outside diameter pipe LM 0

15.1.1.6 63 mm outside diameter pipe LM 0

15.1.1.7 80 mm outside diameter pipe LM 0

Isolation Valves

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1555/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
complete with all accessories and fittings, all as
specified as shown drawings.

Gate Valve
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0

15.1.2 Electric Water Heaters 0

Supply, install, test and commission Electric Water


Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

15.1.2.2 EWH-2 (50 Liter) No. 0

15.1.2.3 EWH-3 (80 Liter ) No. 0

15.1.2.4 EWH-4 (100 Liter) No. 0

15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1556/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float
switches, electric connections and accessories, all as
specified and shown on the drawings

15.1.3.1 WT- ( 8000 L ) No. 0

15.1.5 Pumps 0

SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS


Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0

15.1.6 Domestic Water Booster Set 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1557/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) as shown on drawings, complete with
but not limited to control box, skid mounted, installed,
connected and tested complete with stainless steel
headers, pump individual isolating ball valves, check
valves, isolating butterfly Gate valves PN 16, lug and ,
strainer PN 16, flexible connections, concrete inertia
pad, house pad, vibration eliminator pad, low level
control float switches, pressure switch dry run
protection and controls all supplied from pump
manufacturer diaphragm tank (s), food quality
synthetic rubber membrane, steel painted body,
working pressure 10 bars with isolating valve and
pressure gauge, electric connections, wiring and
accessories all as specified and shown on the drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.1.6.1 BP-1 (45 gpm /43 ft ) Set 0

15.2 FIRE FIGHTING SYSTEM 0


All fire fighting work must be applying NFPA code and
civil defence ,drawing and specifications

Supply, install, test and commission multi purpose


class ABC dry powder fire extinguisher, complete with
all necessary hangers and support. The rate shall
include Stainless steel cabinet with glass door to
contain the extinguisher. "FIRETECH, SAFFECO, AL-
MANAHEL or equivalent as per owner instructions"

15.2.1 F.X-1 ( 6kg ) No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1558/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Wall mounted
class K portable fire extinguisher, with safety valve, fit
internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.2 F.X-2 ( 6 kg ) No. 0

Supply, install, test and commission fire blanket, fit


internal standard, and fire department conditions
"FIRETECH, SAFFECO, AL-MANAHEL or equivalent as
per owner instructions"

15.2.3 Fire blanket No. 0

15.3 PLUMBING FIXTURE APPLIANCES 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1559/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
supplying, installing, connecting and testing vitreous
china trim and accessories with colour and model and
color as approved from consultant or owner
representative complete, including water feed, soil,
waste and vent branch piping works to mains including
adapters, branches, tees, valves, supports from
galvanized steel, brackets, hangers ,shelves, siphon,
terminal isolation angle valves ..etc. all as
specifications, drawings and water consumption
rationalization specifications

Water Closet No.


Western type vitreous china water cloSet complete
with flush tank, seat cover, chromium plated flexible
perennial spray with hook, all necessary fittings and
connection as specified. (Ideal standard or eqivlant)
15.3.1.1 WC-01 0
15.3.1.2 WC-02 I 0

Lavatories No.
Vitreous china wash basin with rear over flow for wall
mounting complete with vitreous china pedestal,
porcelain shelf, wash basin mixer grohe or equivlant
and 800x900mm wall mirror with chamfered edge
including all the necessary fittings & accessories and
approved by the owner .(Ideal standard or equivlant)

15.3.2.1 ( Lav-01 ) 0
15.3.2.2 ( Lav-02 ) 0

kitchen sink No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1560/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Supply and install kitchen sink stainless steel 32 in
,complete, including water feed, waste and vent
branch piping works to mains including adapters,
branches, tees, valves, mixer, supports, brackets,
hangers , siphon ..etc. all as specifications, drawings
and water consumption rationalization specifications all
model must approved from owner representative and
consultant. (mixers are grohe or equilant)

15.3.6.2 Double bowl (KS-02) No. 0

Shower Hand mixer


Shower Hand mixer complete with all acessories and
shower spry head and hose (grohe type or eqivlant) as
per owner representative and consultant.)

15.3.9.1 SH-01 (sypply and install) No. 0

15.4 STORMWATER AND DRAINAGE SYSTEM 0

15.4.1 Pipework 0

Supply, install, test and commission UPVC pipes


installed jointed and tested complete, to BS 4514, BS
5255,BS EN 1329-1 and BS 4660 & BS EN 1401-1 as
applicable including supports, hangers using clamps
with rubber inlay, threaded rods, fittings, accessories,
fire stop jackets, excavation trenches embedment
concrete encasement earthwork cleanouts and
backfilling all as specified and shown on drawings.
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.1 50 mm diameter pipe LM 2

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1561/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.4.1.2 80 mm diameter pipe LM 5

15.4.1.3 110 mm diameter pipe LM 10

15.4.1.4 160 mm diameter pipe LM 0

15.4.1.4.1 200 mm diameter pipe 0

Floor Drain

Supply Floor Traps, trapped gulley type, ABS or UPVC


body, three 50mm inlets, one outlet, 70mm deep water
seal installed, connected and tested complete with
stainless steel grating (150x150mm), extension piece
and accessories all as specified and shown on
drawings..SAUDI CAST, MOFAC , RIYADH FOUNDRY or
equivalent as per owner instructions"

15.4.1.5 FD-80 mm outlet diameter No. 1

15.4.1.6 FD-110 mm outlet diameter No. 0

Floor Cleanout

Supply Floor cleanout stainless steel cover and frame


installed connected and tested complete with
accessories all as specified and shown on drawings..
APLACO, NEPRO, SAPPCO, or equivalent as per owner
instructions"

15.4.1.7 FCO- 110mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1562/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.4.1.8 WCO- 110mm No. 0

Trench Drain

Supply Trench drain, stainless steel gutter & grating


for kitchen area, installed, connected, and tested
complete including frame, concrete work,
waterproofing, earthwork and accessories, all as
specified and shown on drawings.SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.4.1.9 Trench Drain size ( 1.0 x 0.3 x 0.15)m No. 0


Inspection room
Constructing , connecting and testing of inspection
chamber complete with heavy duty cast iron cover,
15.4.1.9.1 fram, and all other accessories as specifiedations and 0
as shown on drawings .

Submersible Pumps

Supply, install, test and commission Duplex


submersible pumps complete with Floats, Control
Panel, Electrical Connection, Valves, Manhole Covers,
and all related works as shown on drawings.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"
SP-02 (35 GPM / 18 FT ) (two pump cascaded)
15.4.1.11 set 0
15.4.1.12 SP-03 (110 GPM / 25 FT ) (two pump cascaded) set

Transfer pump

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1563/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Supply, install, test and commission Domestic water
booster Set, consist of two vertical multi-stage pumps
( changeover ) variable speed as shown on drawings,
complete with but not limited to control box, individual
VSD, skid mounted, installed, connected and tested
complete with stainless steel headers, pump individual
isolating ball valves, check valves, isolating valves PN
16, lug and , strainer PN 16, flexible connections,
concrete inertia pad, house pad, vibration eliminator
pad, low level control float switches, pressure switch
dry run protection and controls all supplied from
pump , food quality synthetic , and pressure gauge,
electric connections, wiring and accessories all as
specified and shown on the drawings. "Grundfos ,KSB ,
Aurora or equivalent as per owner instructions"

Tp-01 (300 GBM /135FT ) (two pump cascaded) set

Roof Drain
Supply Roof drain outlets, PVC body, dome/scupper
type, bottom outlet, polypropylene dome, UV
stabilized installed, connected, and tested complete
with accessories all as specified and shown on drawing.

15.4.1.15 RD, 110mm outlet diameter No. 1

15.4.1.16 RD, 75mm outlet diameter No. 0

Down spout
Supplying, installing, connecting, and testing down
spout nozzle including joints and all necessary to
fixation as specified and as shown on drawings

15.4.1.16.1 110mm outlet diameter 0

Roof Vent Cap

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1564/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Supply Roof vent and cap, UPVC body, installed,
connected, and tested complete with accessories, all
as specified and shown on drawings SAUDI CAST,
MOFAC , RIYADH FOUNDRY or equivalent as per owner
instructions"
15.4.1.19 Type RVC, 110 mm diameter pipe No. 1

15.5 HVAC SYSTEM 0


BUILDER'S WORK RELATED TO MECHANICAL
WORKS

The contractor shall provide builder's work required by


the mechanical systems including but not limited to
boring, making sleeves, anchoring, concrete bases for
mechanical equipment, cutting and patching of walls
and slabs for passage of tubes and ducts, fixing of duct
15.5.1.1 hangers and supports to structures, excavation and LS 1
backfilling, scaffolding, rigging, hoisting, waterproofing,
cleaning and painting …etc. and any other like work
related to proper installation of mechanical systems

LABELING AND IDENTIFYING

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1565/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Install engraved plastic-laminate sign or equipment


marker on or near each major item of mechanical
15.5.2.1 equipment. Identify air supply, return, exhaust and LS 1
intake ducts with duct markers; or provide stenciled
signs and arrows, showing duct system service and
direction of flow, as per specifications

15.5.3 AIR CONDITIONERS UNITS 0

Supply, install test & commission A/C units,Inverter


model, heat pump including outdoor unit, indoor unit,
condensate drain connection all interconnecting pipe
work between outdoor and indoor units, all control
wiring and cabling between outdoor and indoor units,
thermal insulation with canvas and lagging adhesive
on suction line with protection on all refrigerant piping,
15.5.3.2 power connections between the isolator switch and the 0
outdoor unit, vibration isolators, hangers for the indoor
units, anti-vibration pad for the outdoor unit. The unit
price shall also include remote control unit with three
speed switch and antifreeze thermostat for outdoor
unit. By Daikin manuf. or equivelant

Split Wall mounted Type - For service Drivers ,


Maid stores ..
15.5.3.2.1.12 WDX-01 - 1TR No. 0

15.5.3.2.1.13 WDX-02 -1.5TR No. 2

15.5.3.2.1.14 WDX-03 -2TR No. 0

15.5.4 AIR MOVERS: CENTRIFUGAL FANS AND AXIAL 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1566/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission,


Centrifugal Fresh air fan unit, with diffrent static as per
schedule including steel bases, frames, rubber pads,
sealers for leakage, flexible connections with ducts,
guard screens, gooseneck, sand filters and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. . "Saudi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.43.1 FAF-B-013 No. 0

15.5.4.43.2 FAF-B-014 No. 0

Supply, install test & commission exhaust fan unit,


roof mounted/ inline fan types , , belt driven,
centrifugal blower including steel bases, frames,
rubber pads, sealers for leakage, flexible connections
with ducts, guard screens, gooseneck, sand filters and
all required accessories , with all fixing, support, back
draft damper , speed controller, and all required
accessories for proper installation and operation as per
schedule of equipments and specifications. as per
specs and dwgs. . "suadi fans , greenheck, ASEM or
equivalent as per owner instructions"

15.5.4.55 Centrifugal in line fan 0

15.5.4.87 EXF-B13-B-01 No. 0

15.5.4.88 EXF-B14-B-01 No. 0

15.5.4.89 EXF-B16-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1567/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
15.5.4.90 EXF-B17-01 No. 0

15.5.4.90.1 AEX-B02-01 NO 0
15.5.4.90.2 AEX-B04-02 0

Supply, install, connect, test and commission, Cassette


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications. Supplier "Saudi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.91 CEX-01 No. 0

Supply, install, connect, test and commission, Window


type for toilets exhaust, and all required accessories for
proper installation and operation as per schedule of
equipments and specifications Supplier "suadi fans ,
greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.99 EXF-B16-2 NO 0

15.5.4.100 EXF-B17-2 NO 0

Supply, install, test and commission centrifugal in line


Jet exhaust fan for Car parking, fans shall be able to
operate for no less than one hour at high temperature ,
complete with steel bases, steel box, frames, rubber
pads, sealers for leakage, access panels , flexible
connections with ducts, guard screens, back draft
damper with all fixing, support, grease drain , and all
required accessories and all required accessories for
proper installation and as per specs & dwgs. "suadi
fans , greenheck, ASEM or equivalent as per owner
instructions"

15.5.4.101 Jet fans No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1568/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.5.5 Condensate Pipework 0

Supply UPVC pressure pipes to BS 3505 class E solvent


cement jointed, installed and tested complete with
fittings, accessories, supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement,
rate shall include thermal insulation with 12mm thick
armflex. all as specified and shown on
drawings..APLACO, NEPRO, SAPPCO, or equivalent as
per owner instructions"

15.5.5.1 25 mm outside diameter pipe LM 5

15.5.6 Ductwork 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1569/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Supply, install, connect, test and commission Supply


and return, exhaust and fresh air Galvanized steel
ductwork with zinc coating grade Z 275 to BS EN
10142 or ASTM A525 (G90) connected and tested
complete with joints, reinforcements, Volume Dampers,
15.5.6.1 KG 0
vanes, splitter dampers, access doors, elbows,
reducers, fittings, hangers, supports using galvanized
steel channels, duct sealant and accessories all as
specified and shown on drawings.. SABIC, NIPPON,
KHOLUSE or equivalent as per owner instructions"

Supply, install, connect, test and commission black


steel sheet metal duct works (G16) used in kitchen
hoods exhaust including hangers, supports, rods, bolts,
duct mounted access doors and panels, sealant,
15.5.6.2 flexible connectors, volume dampers, fire dampers, No. 0
painted with red epoxy as per SMACNA
recommendations and all required accessories for
proper installation and operation as per specs and
drawings.

Supply, install, connect, test and commission stainless


steel hood used for kitchen euipment exhaust including
15.5.6.3 baffle filters, cartridge filters, grease extraction and all No. 0
accessories needed to complete the work. as per BWW
standards and requirements ( installation only ).

Supply, install, test and commission powder coated


aluminum exhaust air grills including connections to
ductwork with plenum box , volume damper for
balancing purposes, mounting, fixings and all required
accessories as per specs and dwgs.

15.5.9.19 EG-01 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1570/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
Supply, install, connect, test and commission, powder
coated aluminum exhaust air louver with gravity
shutter, opposite blade control volume damper,
rectangular shape, When the louvers units are installed
in walls or masoNo.y slabs, the price shall include a
wooden frame and rubber caulking and approved
grouting put into the opening before installing in walls
or masoNo.y slabs, price shall also include connections
to duct work, sizes as per drawings. Rabeea, GGC,
Beta, or equivalent as per owner instructions"

15.5.9.68 EAL-B13-01 No. 0

15.5.9.69 EAL-B14-01 No. 0

15.6.9 Diesel Tank 0


Supply install test and commison daily tank for
15.6.9.1 No. 0
genertors as specifed

SWIMMING POOL SYSTEM AND FOUNTAINS 0


15.7

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1571/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.7.1 PVC Pipes 0

Supply PVC pressure pipes for fountains and swimming


pool water manufactured according to BS , solvent
cement jointed, installed and tested complete with
fittings, accessories,supports, hangers using clamps
with rubber inlay, threaded rods, galvanized steel
channels, sleeves, pipe marking, expansion joints,
including earthwork, backfill, concrete encasement, all
as specified and shown on drawings. APLACO, NEPRO,
SAPPCO, or equivalent as per owner instructions"

15.7.1.1 25 mm LM 0

15.7.1.2 32 mm LM 0

15.7.1.3 40 mm LM 0

15.7.1.4 50 mm LM 0

15.7.1.5 63 mm LM 0

15.7.1.6 75 mm LM 0

15.7.1.7 110 mm LM 0

15.7.1.8 160mm LM 0

15.7.2 Swimming pool pump 0

Supply, install, test & commission filter pumps,


complete with built-in basket strainer, 2900 RPM

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1572/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.7.2.7 FP-B19-1 No. 0

15.7.3 Inlet Fitting 0

Supply ABS wall mounted , adjustable jet, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.3.3 Pool inlet fitting IF, 63mm diameter No. 0

15.7.4 Vacuum Fitting 0

ABS vacuum , threaded connection, installed,


connected and tested complete including PVC no-leak
flange and accessories, all as specified and shown on
drawings

15.7.4.1 Vacuum fitting VF, 63mm diameter No. 0

15.7.5 Main Drain 0

Supply ABS frame and grate, installed, connected and


tested complete with accessories, all as specified and
shown on drawings

15.7.5.1 Main drain MD No. 0

15.7.6 Overflow Trench Fitting 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1573/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Supply and install overflow trench plastic gutter and


grating 300mm width including frame, concrete work,
waterproofing, earthwork and accessories all as
spesified and shown on drawings.

15.7.6.1 Overflow Trench LM 0

15.7.7 Outlet Fitting 0

Supply Chrome plated , 82 mm diameter, threaded


connection, installed, connected and tested complete
including PVC no-leak flange and accessories, all as
specified and shown on drawings

15.7.7.1 Outlet fitting 75mm diameter No. 0

15.7.8 Fill Fitting 0

Initial fill fittings, installed and tested, complete with


accessories, all as specified and shown on drawings.

15.7.8.1 Initial fill fittings, 20 mm diameter No. 0

15.7.9 Pool Sand Filter 0

Supply and install pool sand filter, FRP material


construction with suitable lining, working pressure min.
3.5 bars test pressure min. 5bars, installed connected
and tested complete including three layer filtering
media beds, , internal distribution system, pressure
gauge, air release valve, drain plug, bronze backwash
sight glass, and accessories all as specified and shown
on drawings

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1574/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.7.9.4 SF-B19-1 Set. 0

15.7.10 Chemical Feeding and Control Accessories 0

Supply, install and test Hypochlorination automatic


dosing feeder with polyethylene tank and accessories

15.7.10.1 CH D.P-1 ( 0.60 L / hr ) No. 0

Supply, install and test PH / Chlorine level controller


with wiring and electric connections

15.7.10.2 PH.D.P-1 ( 0.60 L / hr ) No. 0

15.7.10.3 Chemical test kit No. 0

15.7.11 Balance Tank 0

Supply Water tank, 4-layers polyethylene construction,


vertical type, installed, connected, and tested
complete, including access manhole, float valve, vent
cowl with vermin screen, overflow pipe, drain valve,
isolating valve, level switches, electric connections and
accessories, all as specified and shown on the drawings

Capacity (6) m3
15.7.11.2.1 BT-B22-1 No. 0

15.7.12 Electrical Heat Exchanger 0

Supply Stainless steel pool heat exchanger, installed


and tested complete with Digital Thermostat, valves,
control valve & all related works as specified and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1575/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
shown on drawings.

Pool Heat Exchanger H.X


15.7.12.1 P- HE-01 (21 KW) No. 0

15.8 MECH. GENERAL SITE WORKS 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1576/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
SITE WORKS
15.8.1 MANHOLES AND STRUCTURES 0

Supply, install test & commision Concrete


construction manholes complete with drainage fittings,
steps, galvanized steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.1 Ref. MH-S-00 (0.45m-1.5m depth) No. 0


15.8.1.2 Ref. MH-S-00 (1.55m-3.0m depth) No. 0
15.8.1.3 Ref. MH-S-00 (3.05m-6.0m depth) No. 0

Supply, install test & commision Concrete


construction rain manholes complete with drainage
fittings, steps, grating steel covers and all required
accessories as per specs and Drawings SAUDI CAST,
RABITAL, MAZAYA or equivalent as per owner
instructions"

15.8.1.4 Ref.RWM- 00 (0.45m-1.5m depth) No. 0


15.8.1.5 Ref.RWM- 00 (1.55m-3.0m depth) No. 0
15.8.1.6 Ref.RWM- 00 (3.05m-6.0m depth) No. 0

15.8.2 SITE WATER DISTRIBUTION 0

Supply, install test & commision HDPE, pipe for water


pipework under ground and inside trench complete
with all necessary fittings, valvesand supports,proper
span, rubber seals, expansion loops and joints for long
straight run pipe in accordance with installation
requirements and as per drawing and spec's. APLACO,
NEPRO, SAPPCO, or equivalent as per owner
instructions"

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1577/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.8.2.1 20 mm. L.M 0


15.8.2.2 25 mm. L.M 0
15.8.2.3 32 mm. L.M 0
15.8.2.4 40 mm. L.M 0
15.8.2.5 50 mm. L.M 0
15.8.2.6 63 mm. L.M 0
15.8.2.7 80 mm. L.M 0

Supply, install, test and commission water flow meters


15.8.2.08 with cabinet ,isolating valve, and all related No. 0
accessories as per dwg's.

Supply, install, test and commission water valve


chambers inculding isolating valve, fittings , and all
15.8.2.09 No. 0
related accessories as per dwg's.

15.8.2.10 Supply, install test & commision Hose Bibb No. 0

15.8.3 FIRE FIGHTING PIPING (VOID ITEM) 0

Supply, install test & commission Seamless black steel


pipes to ASTM A53 schedule (80) and fixed in
accordance with specification complete with but not
limited to thrust block ,corrosion proof ,coupling
system, fixing anchor to concrete, block work or
metalwork, fittings, valves, automatic vents & all
required accessories as per drawing and spec's .
APLACO, NEPRO, SAPPCO, or equivalent as per
owner instructions"

15.8.3.1 Diam 100mm (4") L.M 0


15.8.3.2 Diam 150mm (6") L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1578/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

FIRE FIGHTING SYSTEM AND EQUIPMENT

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1579/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission fire hydrant with


hose cabinet and complete with all service valve
,accessories thrust block,as per spec's. "FIRETECH,
15.8.3.3 SAFFECO, AL-MANAHEL or equivalent as per owner No. 0
instructions"

Supply, install, test and commission electrical fire


fighting pump completed with header valves control
panel and all accessories as per spec's. "FIRETECH,
SAFFECO, AL-MANAHEL or equivalent as per owner
instructions"

15.8.3.4 FFP-B18-01 (one duity + one stand by) set 0

15.8.4 SEWER & STORM PIPING 0

Supply, install test & commision UPVC PN16 for rain


& drainage pipe work complete with all necessary
valves, fittings, supports and accessories under ground
as per specs. APLACO, NEPRO, SAPPCO, or
equivalent as per owner instructions"

15.8.4.1 Diam 160mm (6") L.M 0


15.8.4.2 Diam 200mm (8") L.M 0

Supply Trench drain, cast iron gutter & grating for


site area, installed, connected, and tested complete
including frame, concrete work, waterproofing,
earthwork and accessories, all as specified and shown
on drawings.

15.8.4.3 1000mm X300mm No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1580/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

LPG PIPING AND TANK


15.8.5 0

Supply, install test & commission, LPG tank as shown


in schedule of equipment with all valves , vaporizer
fittings & accessories to meet all safety parameters
and regulations as per drawing and spec's .

15.8.5.1 5000 LITER No. 0

Supply, install test & commision, Fuel pipes to BS-


1387 Black steel Heavy class- seamless with fast seal
protection tape, as per drawing and spec's .
INTERPIPE, SPS, or equivalent as per owner
instructions"

15.8.5.2 Diam 25mm L.M 0


15.8.5.3 Diam 32mm L.M 0
15.8.5.4 Diam 40mm L.M 0

Supply, install, test and commissionLPG filling cabinet


complete with 65mm (2 1/2") diam. coupling and valve
15.8.5.7 No. 0
for LPG tanks, complete with all accessories as per
drawing and spec's .

15.8.6 DOMESTIC WATER TREATMENT EQUIPMENT 0

Supply, install, test and commission Automatic Sand


filter complete with valves, control valves, check
valves, strainer, fittings, electrical works, protections ,
pipes, manual back wash system, flexible connections,
SET.
contentious operation type, with built in indicated
pressure gauge, and all accessories as per drawings
and spec's Complete with white, tiled, 15 cm concrete
base.

15.8.6.1 F-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1581/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.8.6.2 F-B18-02 Set. 0

15.8.6.3 F-B18-03 Set. 0

Supply, installation ,testing and commissioning of


"Cation" ion exchange water softener fabricated from
MS plate as per IS:2825 (minimum thickness of shell
6mm and dished end 8mm) complete with initial
charge of resins, GI class 'C' face piping, CI butterfly
valves, pressure gauge, hydraulic brine injector,
accessories, painting inside with epoxy paint and
outside with two coat of red oxide primer and two or
more coat of synthetic enamel paint, including
PVC/HDPE brine tank of required capacity suitable for 2
regeneration capacity with resins of approved quality
and make complete in all respects.

15.8.6.4 SOF-B18-01 Set. 0

Supply, install, test and commission Back-wash pump,


complete with control valves, check valves, strainer,
fittings, electrical works, protections and all
accessories as per drawings and spec's "Grundfos ,KSB
, Aurora or equivalent as per owner instructions"

15.8.6.6 BWP-B18-1 Set. 0

Supply, install  test & commission irrigation  pump with


gate valve, check valve, strainers, pressure gauges
and all accessories, as per  dwg's and  spec's.
"Grundfos ,KSB , Aurora or equivalent as per owner
instructions"

15.8.6.7 IRRP-B18-01 Set. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1582/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

15.8.6.8 IRRP-B18-02 Set. 0

Supply, install  test & commission raw  pump with gate


valve, check valve, strainers, pressure gauges and all SET.
accessories, as per  dwg's and  spec's.

15.8.6.9 RWP-B18-01 Set. 0

DIV#15 Total cost of this section Carried Forward To Summary

16 DIV#16 ELECTRICAL WORKS

Main and Secondary Distribution Boards

Section 16440 Switchboards - 600 volts and below

Supply, install, test and commission Main and secondary


distribution boards including all necessary ACB, MCCB's,
bus bars, coupling units, casing, cable clamps, meters,
micro processor metering, lightning surge protection,
protection equipment,all socket MCB should be
earthleakage type for all panels and all needed
accessories as shown on drawings

16.21 Main Distribution boards 0

16.21.1 Ref. SMDB-B13&14 No. 0


16.21.2 Ref. SMDB-S No. 0
16.21.3 Ref. ESMDB-S No. 0
16.21.4 Ref. LV-1 No. 0
16.21.5 Ref. ELV-1 No. 0
16.21.6 Ref. LV-2 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1583/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
16.21.7 Ref. ELV-2 No. 0

16.22 Motor Control Center 0

Section 16443 Motor Control Centres

Supply, install, test and commission Motor control center


including all necessary MCCB's, MCB, bus bars, casing,
meters, contactors, over load, phase failure relays, pulse
relay, indication lamp, push buttons, micro processor,
provision for connection to BMS , lightning surge
protection,accessories, fixings and fittings, and all needed
accessories as shown on the drawings.

16.22.1 Ref. MCC-L No. 0


16.22.2 Ref. MCC-R No. 0
16.22.3 Ref. MCC-B18 No. 0
16.22.4 Ref. MCC-B19 No. 0

16.23 Distribution Boards 0

Section 16440 Switchboards - 600 volts and below


16.23.2 Ref. DP-B/L No. 0
16.23.6 Ref. DL-B/R No. 0
16.23.7 Ref. DB-G/R No. 0
16.23.8 Ref. EDB-B/C1 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1584/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
16.23.9 Ref. EDB-S/S1 No. 0
16.23.10 Ref. EDB-S/S2 No. 0
16.23.11 Ref. EDB-B/C2 No. 0

16.24 Feeder Pillar 1

Section 16440 Switchboards - 600 volts and below


16.24.1 Ref. LPEX1 No. 0
16.24.2 Ref. LPEX2 No. 0

16.25 Feeders 0

Section 16122 600 - Volt Cable

Supply, install, test and commission Feeders, conductors


and cables including all necessary supports, brackets,
pipes, conduits, manholes (if needed), luges, glands, cable
terminals , terminations and electrical connections and all
needed accessories as shown on the drawings.

16.25.1 (1CX630)mm2 CU/XLPE/AWA/PVC L.M 0


16.25.2 4x240 mm2 CU/XLPE/SWA/PVC L.M 0
16.25.3 4x50mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.5 4x10mm² CU/XLPE/SWA/PVC 1x10mm² Y/G PVC L.M 160
CABLE
16.25.6 5x6mm² CU/XLPE/SWA/PVC L.M 0
16.25.7 4x35mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.8 4x25mm² CU/XLPE/PVC +1x16mm² Y/G PVC CABLE L.M 0
16.25.9 4x16mm² CU/XLPE/PVC + 1x16mm² Y/G PVC CABLE L.M 0
16.25.10 4x10mm² CU/PVC/PVC + 1x10mm² Y/G PVC CABLE L.M 0
16.25.13 4x35mm² FIRE RETARDANT CABLE L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1585/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
16.26 A Isolating switches
Supply, install, test and commission Isolating switch
points including all necessary conduits, cables, wires
junction boxes, connections, terminations to equipment ,
PedestaL.S (where needed ) ,and all needed accessories
and as shown on the drawings .

16.26.2 25A, TPN ,IP65 No. 0


16.26.3 32A, SPN ,IP65 No. 0
16.26.4 32A, TPN ,IP65 No. 0

16.27 Power Socket Outlets 0

Sections 16020, 16120, 16130 ,16140

Supply, install, test and commission Socket outlet


including all necessary PVC conduits, wires, cables, pull
and junctions boxes , floor boxes (where needed as per
drawings) ,all necessary covers, boxes and ancillaries
and connections, and all needed accessories and as
shown on the drawings (legrand / MK) or equivlent.

16.27.1 Socket outlet, 13A, 1- phase, 1- gang , switched (wall or No. 5


in floor mounted box)
16.27.2 Ditto but ceiling mounted No. 0
16.27.3 Ditto but water proof No. 1
16.27.4 Ditto but double gang (wall or in floor mounted box) No. 8
16.27.7 Spur outlet for electrical water heater No. 1
16.27.8 20A, double pole switch with neon. No. 1
16.27.10 Socket outlet, 15A, 1- phase, 1- gang , for washer or
No. 0
dryer
16.27.12 Power points for Motorized Camera No. 0

16.28 Lighting System 0


Sections 16010, 16120 ,16510 ,16530

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1586/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Supply, install, test and commission Lighting points


including switches with all necessary conduits,
conductors , cables & wires , junction , pull boxes,
connections, accessories, fittings, and all needed
accessories as shown on the drawings.

16.28.1 Internal Lighting points No. 7


16.28.2 External Lighting points No. 0

16.29 Lighting Fixtures 0

install, test and commission Lighting fixtures and lighting


switches including all necessary transformer ballast,
switch gear, lamps, lamp holders, diffusers, internal
wires, supports, clamps, conduits, connections,
terminations, fixings, fittings and all needed accessories
and as shown on the drawings.

16.29.1 Type F1 No. 0


16.29.4 Type F4 No. 1
16.29.5 Type F5 No. 0
16.29.6 Type F6 No. 1
16.29.8 Type F8 No. 1
16.29.9 Type F9 No. 0
16.29.11 Type F11 No. 1
16.29.16 Type F15 No. 3
16.29.17 Type F15E No. 0
16.29.21 Type F19 No. 0
Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1587/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
16.29.25 Type EX3 No. 0
16.29.26 Type EX4 No. 0
16.29.27 Type EX5 No. 0
16.29.28 Type EX6 No. 0
16.29.29 Type EX7 No. 0
16.29.30 Type EX8 No. 0
16.29.31 Type EX9 No. 0
16.29.32 Type EX10 No. 0
16.29.33 Type EX11 No. 0
16.29.42 Type EX20 No. 0
16.29.43 Type EXT. 1 No. 0
16.29.44 Type EXT. 2 No. 0
16.29.45 Type EXT. 3 No. 0
16.29.47 Type EXT. 5 No. 0
16.29.48 Type EXT. 6 No. 0

16.3 Fire Alarm Installation 0

Sections 16710 Fire Alarm

Supply, install, test and commission a fire alarm panel


including indication lamps, reset button, switches,
batteries, charger, internal conductor, enclosure and all 0
16.30.1 other accessories necessary to provide a complete fire
alarm system and as shown on drawings. The panel
should be capable of connecting to an auto-dialer.

16.30.1.1 Fire alarm control panel, ref. MFACP (20 loop) No. 0
Repeater Fire alarm control panel,ref.RE.MFACP-M (20 1
16.30.1.2 No.
loop)

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1588/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

Fire alarm devices including covers, fixings ,conductors,


conduits, pull and junction boxes, cables, wires, 0
16.30.2 connections and terminations, and all needed accessories
as shown on the drawings.

16.30.2.1 Addressable smoke detector No. 0


16.30.2.2 Addressable smoke detector with sound base No. 3
16.30.2.3 Addressable heat detector No. 0
16.30.2.4 Addressable heat detector with sound base No. 0
16.30.2.5 Break glass station No. 1
16.30.2.6 Audible/visual warning devices indoor No. 0
16.30.2.7 Audible/visual warning devices outdoor No. 1
16.30.2.8 Control module (CM) No. 1
16.30.2.9 End of line resistane (E.O.L) No. 1

16.31 EARTHING SYSTEM 0

Sections 16125 EARTHING


16.31.1

Supply, install, connect and test the building earthing


system as per drawings and specifications consists of
main loop with 95mm2 bare copper or suitable conductor
size as,equilizer bar and test link ,4 earthing pits, various
corner earthing points of the building , connected with 0
L.S
SMDB-XX or main building panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1589/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
16.31.2

Supply, install, connect and test the swimming pool


earthing system as per drawings and specifications
consists of main loop with 95mm2 bare copper or suitable
conductor size as,equilizer bar and test link ,4 earthing
pits, various corner earthing points of the building , 0
L.S
connected with simming pool panel in Electrical room for
the building earthing with required number of earthing
conductor and pits as per building area specification&
engineer approval , The earth resistance shall not
exceeds 5ohm.on all testing points

16.32
Supply, install, test and commission Main data rack
including cabinet with ventilation fan, voice data rack
optical fiber drawer, axes wire, power supply , cables and 0
connections, and all needed accessories and as shown on
the drawings.

16.32.1 ref. M.D.C-1 No. 0


16.32.2 ref. M.D.C-2 No. 1

16.33 CCTV SYSTEM 0

Sections 16690 IP network components

Supply, install, test and commission IP-CCTV camera


including all necessary conduits, wires, cat6A or fiber
cables , pull junction boxes, connections and
terminations, and all needed accessories as specified and
as shown on the drawings.

16.33.1 Fixed INDOOR IP-camera No. 0


16.33.2 Weather proof Fixed IP-camera , pole mounted No. 1

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1590/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
16.33.3
Weather proof motorized IP camera , wall / col. Mounted No. 0

Supply, install, test and commission CCTV main set,


including matrix monitors, switches, video services, alarm
monitors, NVR, PC computer, key board, all necessary 0
16.34 L.S
conduits, wires, cables, connections and terminations, and
all needed accessories as specified and as shown on the
drawings.

16.35 LOW CURRENT SYSTEMS 0

Sections 16110, 16120, 16130, 16140, 16690 IP network


components

Supply, install, test and commission Telephone / Data /


IP-TV sockets outlets including all necessary covers,
fixings ,wires, cat6a or fiber cables, cable terminals,
cable trunks and baskets ,conduits, pull and junction
boxes, floor boxes (where needed as per drawings) ,
connections from data rack to the outlet, and all needed
accessories as shown on the drawings by legraned or
equivalent .

16.35.1 RJ45 telephone socket outlett in wall mounted box No. 1

16.35.2 RJ45 data socket outletr in floor mounted box No. 1

RJ45 Data socket outlet , ceiling/ wall mounted , for IP- 0


16.35.3 No.
camera
16.35.4 RJ45 access point installed above false ceiling No. 0

16.35.5 RJ45 socket outlet for IP-TV -optional No. 1

Supply ,test and commission a digitally controlled


16.35.6 Professional VOIP ,analog Telephone (EPABX). No.

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1591/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

MULTI-MODE 4-CORE FIBBER CABLES FOR all 0


16.35.9 L.M
buildings

16.36 Transformer (coordinated item with SCECO) 0

1500KVA , 60 Hz, Dry type step down power transformer


including all necessary bus bars, coupling units, casing,
16.36.1 cable clamps, earthing and protection equipment, and all No. 0
needed accessories as electrical company requirements
and as shown on the drawings

16.37 GENERATOR ASSEMBLIES


SECTION 16620, 16450 0

DIESEL ENGINE DRIVEN GENERATING SET

Supply, install, test and commission, 400V, 60Hz


1500rpm standby diesel power Generator set , including
control panel, battery starting , cooling , fuel,diesel
tanks , earthing , lubricating , primary & secondary
silencer (if needed), and all needed accessories as
specified and as shown on the drawings

16.37.1 300KVA Generator (G-1) No. 0


16.37.2 150KVA Generator (G-2) No. 0

4-Pole automatic transfer switch (ATS) , complete with


control wires connection to generator sets ,controlled by
16.38 BMS ,and all needed accessories as specified and as 0
shown on the drawings

16.38.1 400A ATS No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1592/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY
16.38.3 180A ATS No. 0
16.38.4 80A ATS No. 0
16.38.7 40A ATS No. 0
16.38.8 32A ATS No. 0

16.39 Conduits 0

Section 16010, 16020 , 16110

General Site works including all UPVC conduits , power


manholes , Telecommunication manholes medium duty
steel cover , duct banks, pipes,13.8kv medium voltage
buried cables, incoming telecommunications cables and all
needed accessories as , specified and as shown on the
drawings

900mmx900mmx800mm concrete manhole,


16.39.1 medium duty steel cover for L.V cables No. 0

800mmx800mmx800mm concrete manhole,


16.39.2 medium duty steel cover for L.V cables No. 0

600mmx600mmx800mm concrete manhole,


16.39.3 medium duty steel cover for L.V cables No. 0

800mmx800mmx700mm concrete manhole,


16.39.4 medium duty steel cover for TELECOM. cables No. 0

600mmx600mmx700mm concrete manhole,


16.39.5 medium duty steel cover for TELECOM. cables No. 0

300mmx300mmx700mm concrete manhole,


16.39.6 medium duty steel cover for Cameras cables No. 0

16.39.7 Ø100 uPVC conduits L.M 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1593/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
16 / ALL DISCIPLINES

Secondary

ITEM DIV B20


DESCRIPTION UNIT
# # QTY

16.39.8 Ø75 uPVC conduits L.M 0

16.39.9 Ø50 uPVC conduits L.M 0

16.39.10 Ø32 uPVC conduits L.M 0

DIV#16 Total cost of this section Carried Forward To Summary

G/Total Subaie Complex (Div 1~16) Carried Forward To Summary

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1594/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount

1 DIV#1 GENERAL REQUIREMENTS FOR BOQ

1.1 see seprate BOQ for Div # 1 ( general requirments for BOQ LS -

DIV#1 Total cost of this section Carried Forward To Summary 0

2 DIV#2 SITE WORKS


PARTLY / ARCH. WORKS ONLY 0
0
Complete the following (Architectural / Partial) items 0
as specified in the drawings & specifications. i.e. 0
02213, 02620, 02625, 02630, 02641, 02811 0
0
2.1 External Fence Wall 0
0

Supply and apply external textutre paint on concrete ,


2.1.1 m2 0
sample to be approved by celint

0
0
Concrete Curbstone
Excluded- At this stage
2.1.2 Supply & install 150 x 350 x 500 mm Precast LM
concrete curbstone, complete with all the
required components including preparation of
underneath layer & blinding concrete as
specified in the drawings

Cement Tiles / Pavers


Excluded- At this stage

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1595/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
2.1.3 Supply and install 400 x 400 x 40mm cement tiles for m2
walkway areas round the building, complete with all
the required components to complete the work
including preparation of underneath layer and as
specified in drawings and specifications.

Car Driveway
Excluded- At this stage
2.1.4 General preparations as per design levels and laying m2
of asphalt concrete pavement on level sub base
surface compacted density not less than 95%
including grubbing and grading to proposed design
levels with the following components as specified in
the drawings and specification including paint
marking as follows:
-200 mm stabilized aggregate base course
-MC1 spray application
-70 mm thick bituminous base course
-RC2 spray application
-30 mm thick bituminous wearing / surface course
-Paint marking
0
Car Wheel Stopper 0
0
2.1.5 Supply and install 150 x 350 x 2000 mm Precast No.
car wheel stopper complete with all the 0
required components for stopper cars . 0
0
Football Field / Playground 0
Excluded- At this stage 0
2.1.6 Preparation of football ground, including leveling, No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1596/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
agriculture soil & Bermuda gross etc. Size 18×26 meter 0
(For Mr. Ibrahim Group) 0
0
2.1.7 Ditto, but Size 17×35 meter (For Mr. Abdul Aziz) No. 0
0
2.2 LANDSCAPE: 0
Excluded- At this stage 0
Supply and for complete with all the required 0
components to complete the work including 0
preparation of underneath layer and as specified 0
in drawings and specifications. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1597/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
0
Green Area 0
Excluded- At this stage 0
2.2.1 1.25 meters wide Green Belt all around the main LM 0
swimming pool in the center of the buildings 0
connecting to 2.00 meters wide 4 Nos. Gates. 0
0
2.2.2 Trees with 100mm thick layer of clean loose m2 0
gravel as dust protection (and/or) as approved. 0
0
2.2.3 Ditto but with out gravel beside the fence LM 0
0
Interlock 0
Excluded- At this stage 0
2.2.4 80mm thick Yellow color CONCRETE PAVING m2 0
BLOCKS (AS OWNER SELECTION) 0
0
2.2.5 Ditto but, Brown color m2 0
0
Stone Walkways 0
Excluded- At this stage 0
2.2.6 Supply and installation of stone slabs, including m2 0
underneath preparations. 0
0
Villas Private Entrances 0
Excluded- At this stage 0
2.2.7 Private entrances for villas between car ways m2 0
and buildings as per drawing. 0
0
Link Between Villas 0
Excluded- At this stage 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1598/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
Walkways links between the villas and includes 0
work finishes and paints flowers of different 0
levels according to the design 0
0
2.2.8 Villa Mr. Mr. Adel & Duplex Mr. Mohammed LM 0
0
2.2.9 Villa Mr. Adel and Majid LM 0
0
2.2.10 Villa Mr. Ibrahim and duplex Mohamed LM 0
0
2.2.11 mother villa and Mr. Mr. Abdul-Aziz LM 0
0
2.2.12 villa Mr. Mr. Abdul-Aziz and duplex villa LM 0
0
2.2.13 2 duplex Mr. Mr. Abdul-Aziz villa LM 0
0
2.2.14 Duplex Mr. Abdul-Aziz and Mr. Nasir villa LM 0
0
Void Open Spaces (Between Buildings) 0
Excluded- At this stage 0
2.2.15 General preparations as per design levels for open m2 0
void area spaces between buildings & hard/green 0
landscapes to complete ready for any storm water 0
disposal. 0
0
Concrete Ramp 0
0
2.2.16 RAMP concrete thickness of 15 cm epoxy paint No. 0
long 2 m wide 3 meter at SCECO Room 0
0
2.2.17 Ditto but wide 2.3 No. 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1599/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1600/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
2.3 EARTHWORKS 0
0
Excavation & backfilling 0
0
Excavation in any kind of soil, rock, etc, starting at
existing ground levels down to bottom of foundations, 0
complete as per drawings.

0
2.3.1 Site leveling and foundation excavations m3 0
0
Selected imported engineering compacted fill to 95% of
modified proctor test, in layers not exceeding 250mm 0
each, complete

0
2.3.2 Up to levels and around & above foundations. m3 0
0
Crushed aggregate base course, compacted to 100%
0
modified AASHTO density CBR ≥ 80%
0
2.3.3 250mm thick under slabs on grade m2 0
0
2.4 ANTI TERMITE 0
Refer to spesification # 2285 0
2.4.1 Termite control treatment for all vertical and L.S 0
horizontal areas complete in accordance with 0
specifications. 0
0

DIV#2 Total cost of this section Carried Forward To Summary 0

3 DIV#3 CONCRETE WORKS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1601/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
Plain concrete (grade 15), 15N/mm2 at 28 days cylinder
compressive strength, using portland cement, including all
3.1 necessary formwork, (separation layer polyethylene
sheets) 250 micron,

3.1.1 Blinding, 100mm thick under foundations m3 0

3.1.2 Blinding, 50mm thick under slabs on grade m3 0

3.1.4 Blinding, 50mm thick under all types of tie beams m3 0

Cyclopean concrete; comprising of 50:50 plain concrete


and stone

3.1.5 Pedestals under tie beams; size 500x500x500mm m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,SRC , at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
3.2 including high tensile steel reinforcement grade 420Mpa
and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.2.1 Foundations; (single, compound ) m3 0

3.2.1.1 Foundations; (Raft , continous ) 0

3.2.2 Tie beams - Intermediate m3 0

3.2.3 Upper tie beams m3 0

3.2.4 Slabs on grade m3 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1602/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
3.2.5 Walls below slab on grade m3 0

3.2.6 Columns Below slab on grade m3 0

3.2.7 Water Tanks Slabs and Walls m3 0

3.2.8 Swimming pool Slabs and Walls m3 0

3.2.9 Car Park Roof Slab m3 0

Reinforced cast in situ concrete (grade 30), 30N/mm2


,OPC, at 28 days cylinder compressive strength, using
portland cement, including and all necessary formwork,
including high tensile steel reinforcement grade 420Mpa
3.3 and mild steel reinforcement grade 280Mpa (Φ8mm); to

3.3.1 Columns above slab on grade m3 0

3.3.2 Shear Walls , free standing walls above slab on Grade m3 0

3.3.3 Suspended solid slabs; including drop beams m3 0

Ribbed slabs;including hollow concrete blocks and hidden


3.3.4 beams -Ribs m2 0

3.3.5 Stairs (steps, flights and landing) m3 0


0
3.3.6 Beams m3 0
0
0

3.4 CONCRETE PROTECTION AND INSULATION

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1603/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount

Supply, install and test of the liquid applied


polyurethane waterproofing; applied in two layers;
1.5 liters/m2

Supply, install and test of the liquid applied polyurethane


waterproofing; applied in two layers; 1.5 liters/m2

3.4.1 To all structural elements below grade m2 0

4mm thick torch applied SBS modified bituminous


polymer waterproofing membrane, including bitumen
primer, all necessary preparation and fixing
works,protection layer , complete as per drawings and
specifications

3.4.2 To basement's walls - Vertical m2 0


3.4.2.1 Below slab on grade for basements -Horizontal 0
3.4.2.2 Water Tanks 0
3.4.2.3 Swimming pools 0

PVC water stop, web thickness (4-5) mm, complete as


detailed on drawings and as specified

3.4.5 To water tanks; 250mm wide mr 0

DIV#3 Total cost of this section Carried Forward To Summary 0

4 DIV#4 MASONRY WORKS

Concrete masonry units (CMU) for external and

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1604/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
internal wall partitions as specified and shown
in the drawings and specifications. Price shall
include all anchors, joints, mortar, sills & lintels,
jambs (if any), vertical & horizontal
reinforcement, tests and all other related works
to complete all masoNo.ies as specified in the
drawings & specifications i.e. (04200, 04422)

4.1 Composed Walls

4.1.1 350 mm thick wall composed of one layer 150 mm m2


and one layer of 150 mm concrete masoNo.y units
for external wall including reinforcement and 50
mm polyurethane foam insulation as specified in
the drawings & specifications:-

4.2 CMU walls Without Isolation

4.2.1 350 mm thick (CMU) block masoNo.y works to m2


internal / partition walls
0
4.2.2 300 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.3 250 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.4 200 mm thick (CMU) block masoNo.y works to m2 0
internal / partition walls / Parapet 0
0
4.2.5 150 mm thick (CMU) block masoNo.y works to m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1605/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
internal / partition walLS 0
0
4.2.6 100 mm thick (CMU) block masoNo.y works to m2 0
internal /partition walLS 0
0
4.3 Forming of Arch. Shape 0
0
4.3.1 Construction of block masonry works, to get m3 0
shape as per architectural design .

DIV#4 Total cost of this section Carried Forward To Summary 0

5 DIV#5 METAL WORKS LS 0

NA

DIV#5 Total cost of this section Carried Forward To Summary 0

6 DIV#6 WOOD & PLASTIC LS 0


NA

DIV#6 Total cost of this section Carried Forward To Summary 0

7 DIV#7 THERMAL & MOISTURE

7.1 Waterproofing

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1606/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount

Supply, installation and testing of the following


waterproofing, thermal and moisture protection
system over R.C. Slab (roof deck), including all
the necessary components and accessories to
complete the work as specified in the drawings and
specifications i.e. (07105, 07155, 07211, 07800,
07951) Price shall include for all vertical up-stand,
termination & mechanical fixations etc. (submit
details with ten years warranty for approval)

Exposed Roof Areas

7.1.1 Supply, install and test of the following thermal and m2 0


moisture protection and waterproofing consisting 0
of 40 mm smooth finish sloping screed over roof 0
slab, 3+3 modified bituminous waterproofing 0
membrane over primer, including 50mm thick 0
extruded polystyrene boards 35KG/m3, separation 0
layer 140KG/m2 and finish Cement tiles 300x300x30mm to 0
horizontal and vertical areas as shown and 0
specified in the drawings and specifications. 0
0
7.1.2 Ditto, but without roof boards along parapet LM 0
vertical up-stand 150 mm above from roof finish 0
level, including aluminum flashing 100 mm wide 0
and 1.5 mm thick at termination level as specified 0
in the drawings and specifications. 0
0
Wet Areas (Bath Rooms & Kitchens) 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1607/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
7.1.3 Supply, install and test of the liquid applied m2 0
polyurethane waterproofing type (black P.U.) to be 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire flat areas including vertical and horizontal 0
penetrations, drains and to be self-terminated at 0
minimum 100 mm above the floor finish level 0
including separation layer, screed protection (or) 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
Planter Boxes & Green area 0
Excluded- At this stage 0
7.1.4 Construction of planter boxes at basement, 0
LS
including agriculture soil, plants and waterproofing 0
if required, Finishing with the outside marble or 0
ceramic ( choose Owner ) complete ready in all 0
respect, Size as follows: Area : 2.00 m2 0
0
7.1.5 Ditto, but Size is : 2000×500×1000 mm in height No. 0
0
7.1.6 Ditto, but Size is : 3400×500×1000 mm in height No. 0
0
7.1.7 Ditto, but Size is 1350×1250×400 mm in height . No. 0
0
7.1.8 Ditto, but Size is 1300×900×400 mm in height . No. 0
0
7.1.9 Ditto, but Size is 14 meter ×650×400 mm in height . No. 0
0
7.1.10 Ditto, but agriculture soil, plants and waterproofing No. 0
only with out Construction in family sitting Size is : 0
1600 mm2 . 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1608/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
0
7.1.11 GARDEN Inside the building m2 0
0
7.1.12 Green area out side the building beside the ramp No. 0
round shape radius1.65 meter 0
0
7.1.13 Green area in side the building with gravel m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1609/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
0
7.1.14 Green area out side the building m2 0
0
7.1.15 Green area out side the building four levels m2 0
from +3.5 to +5.4 0
Swimming Pool & Water Tanks 0
0
7.1.3 Supply, install and test of the liquid applied m2 0
Cement based proofing 0
applied in two (2) layers 1.5 liters/m2 over the 0
entire areas including vertical and horizontal 0
penetrations, drains and to be self-terminated 0
equivalent and all necessary components to 0
complete ready facility as specified. 0
0
DIV#7 Total cost of this section Carried Forward To Summary 0

8 DIV#8 DOORS & WINDOWS

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1610/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
Supply and installation of complete doors &
windows units including frame and all the
necessary hardware and accessories including
paint as specified in the drawing & specifications.
(08111, 08121, 08200, 08300, 08521, 08700,
08800) & special spesification for wooden doors

Note : Ditto = Matching code only

8.1 STEL & WOODEN DOORS

8.1.1 Model/Type: SD01 Height 2.24 × 1 meter width No. 0


0
8.1.7 Model/Type: SD02 Height 2.24 × 1 meter width No. 0
0
8.1.13 Model/Type: WD01 Height 2.24 × 0.8 meter width No. 0
0
8.1.17 Model/Type: WD02 Height 2.24 × 0.9 meter width No. 0
0
8.1.22 Model/Type: WD03 Height 2.24 × 1 meter width No. 0
0
8.2.139 Model/Type: SD03 Height 2.24 ×1.2 meter width No. 0
0
8.3 SCECO Room 0
0
Selected metal doors of the Saudi Electricity 0
Company with ventilation openings . 0
complete with Metal Paint finsh as per Sceco Standard 0
0
8.3.1 METAL DOOOR Height 2.2 ~ 3.00 × 2.2 meter width No. 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1611/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
8.3.2 Ditto but Size : 2.2× 1.5 meter No. 0
0
8.3.3 METAL WINDOW Height 1 × 2 meter width No. 0
0
8.4 Main Gate & Windows @ Fence Wall 0
0
8.4.1 SLIDING STEEL DOOR WITH WOOD PLANKS No. 0
wide 5 meter 0
0
8.4.2 Double for sub gate wide 4 meter No. 0
0
8.4.2 SINGLE LEAF DOOR WITH WOOD PLANKS No. 0
Size 0.9 × 2.6 meter 0
0
8.4.4 FIXED WINDOW WITH STEEL LATTICE SECURITY 0
GRILLE 0
8.4.4.1 For wide 1.35 No. 0
0
8.4.4.2 For wide 0.60 No. 0
0
8.4.4.3 For wide 0.90 No. 0
0
0
0
DIV#8 Total cost of this section Carried Forward To Summary 0

9.1 DIV#9 FINISHES

Plastering Works

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1612/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount

20 mm thick Portland cement plaster (straight) in


two layers using 400KG cement to (1) m3 of clean
sand and smooth cement finish to concrete and
wall surfaces including wire mesh, lath and plaster
accessories as specified in the drawing and
specifications i.e. (09100, 09310, 09421, 09510,
09680, 09900, 09905) Price shall include interior
and exterior corner and angle beads, plaster stops,
control joints, acrylic sealant and forming of
groove as described to:-

9.1.1 Plastering to walls external sides. m2 0


0
9.1.2 Plastering to walls internal sides. m2 0
0
9.1.3 Plastering to ceiling underneath of R.C roof slab. m2 0
(Painted spaces only) 0
0
9.2 Ceilings Finishes 0
0
Supply and installation of ceiling finishing with 0
all the necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
Inside the building 0
0
9.2.1 Paint to plastered ceiling surfaces underneath of m2 0
R.C slab. (color as to be approved by the client ) 0
0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1613/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
9.2.2 Paint on Concrete m2 0
0
0
9.2.4 G.B = GYPSUM BOARD Ceiling complete with Paint m2 0
0
9.2.12 L.G.B = LAMINATED GYPSUM m2 0
Moisture resistant gypsum board with paint 0
0
9.2.14 AL.P = ALMUNIM PANELS 600×600 mm FOR m2 0
Kitchens 0
0
Wall Finishes 0
0
Supply and installation of wall finishing with all the 0
necessary materials and components as 0
indicated in the drawings and specifications:- 0
0
NOTE :- 0
Upper roof penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.3 External Walls Surfaces 0
0
9.3.1 Exterior finishes of the type EF-01 CEMENT m2 0
RENDERING item includes all installation, 0
protection and accessories and the necessary 0
accessories to terminate the business, according 0
to what is shown on the drawings. installation and 0
protection work with what is shown on drawings. 0
0
9.3.2 Exterior finishes of the type EF-02GRC PARAPET m2 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1614/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
item includes all installation, protection and 0
accessories and the necessary accessories to 0
terminate the business, according to what is 0
shown on the drawings. installation and protection 0
work with what is shown on drawings. 0
0
9.3.3 Ditto but, the upper parts of the windows. m2 0
0
9.3.9 Ditto EF-05 but radius of 375 mm Circle No. 0
0
9.3.21 Exterior finishes of the type EF-07C GRC ARC m2 0
0
0
GRC Panels 0
0
9.3.30 Paint for parapet from internal only m2 0
0
9.3.32 Paint for walls m2 0
0
NOTE :- 0
Upper roof no penthouses, computed as internal 0
finishing type EF-01 Cement Rendering. 0
0
9.4 Internal Walls Surfaces 0
0
9.4.1 Paint the interior walls m2 0
0
9.4.2 VITRIFIED PORCELAIN TILES (200*200*8)mm m2 0
0
9.4.3 CIRAMIC TILES (200*200*8)mm m2 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1615/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
0
9.5 Glass Walls 0
Excluded- At this stage 0
Supply & installation of structural glazing system, 0
as specified in the drawings as per manufacturer 0
standard and in accordance with specifications. 0
Price to includes all necessary accessories, 0
caulking, sealant, grouting & other needed works 0
to complete ready in all respect. The contractor 0
shall submit sectional samples of the system 0
showing all details for client and engineer approval 0
for both aluminum & glass. Structural Glazing with 0
tag/Size as follows: 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1616/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
0
0
9.5.15 Glass wall in the main gate H 1.2 No. 0
0
9.6 Floor Finishes 0
0
Supply and installation of floor finishing with 0
skirting and all the necessary materials and 0
components as indicated in the drawings and 0
specifications:- 0
0
0
9.6.2 VITRIFIED PORCELAIN TILES (Non Slip) m2 0
(300*300*8)mm 0
0
9.6.4 VITRIFIED PORCELAIN TILES (600*600*10)mm m2 0
0
9.6.5 VITRIFIED PORCELAIN TILES (600*300*10)mm m2 0
0
100 mm thk. TROWLLED CONCRETE WITH EPOXY
9.6.11 PAINT INCLUDING SKIRTING 150 MM HIGHT AND m2 0
ROAD MARKS
0
DITTO BU FOR MEP ROOM INCLUDING SKIRTING 150
9.6.12 m2 0
MM HIGHT
0
0

9.7 Stairs Finishes 0


Only for service staires 0
Saudi Binanco Granite - THREAD 30mm 0
THICK)/RISER 20MM THICK price to include 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1617/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
grooves for non-slip material and nose forming as 0
9.7.1 for service build. staircase L.M. 0
0
0
DIV#9 Total cost of this section Carried Forward To Summary 0

10.1 DIV#10 SPECIALTIES

contractor scope is to make sure all Civil & MEP


requirement for installation such items is incoporated in
related works .

SANITARY FIXTURES

Kitchen Accessories
Excluded- At this stage
Supply and installation of following kitchen fixtures
and accessories as specified. i.e. 10800

10.1.1 Kitchen cabinet, counter top with back splash, to 0


be melamine laminated, complete with shelves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1618/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
and dish rack, composing of double bowl 0
stainless steel sink, overhead cabinet with all the 0
necessary fittings and accessories as shown & 0
specified in the drawings. Wall length back to 0
back L.M 0
0
0
0
10.3 MISCELLANEOUS 0
0
0
Internal Stair 0
0
10.3.3 Handrail to external stairs LM 0
0
10.3.4 Handrail to internal stairs LM 0
0
Ladder 0
0
0
10.3.6 Supply and installation of galvanized iron ladder No. 0
Height 3.00 meters.complete with paint finsh 0
0
10.3.7 PVC COATED STEEL LADDER RUNGS 0
To suit water tank - HIGHT 3.3 : 3.72 SET 0

Manhole Covers
0
10.3.7 Stainleass steel frame with stone cover to match Adjacent are No. 0
for water tanks

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1619/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
0
DIV#10 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1620/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
11 DIV#11 EQUIPMENTS LS 0
NA

DIV#11 Total cost of this section Carried Forward To Summary 0

12 DIV#12 FURNITURE LS 0
NA

DIV#12 Total cost of this section Carried Forward To Summary 0

13 DIV#13 SPECIAL CONSTRUCTIONS

13.1 Sky Light

Supply and installation of colored glass panels with

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1621/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
geometric shapes to work on celestial lighting
slots, item includes outer frame, protection and
aluminum panels to strengthen the glass.

13.1.34 Type-34 Size : 28 × 2.4 meter No. 0


0
13.1.35 Type-35 Size : 14.45 × 2.4 meter No. 0
0
0
13.3 SWIMMING POOL FINISH 0
Excluded- At this stage 0
Finished floors and walls of the swimming pool in 0
addition to all kinds of waterproofing with all 0
accessories . 0
0
0
13.3.3 WALL FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
LEVEL -1.8 M 0
0
13.3.4 FLOOR FINISH MOSAICS TILES Color and Size m2 0
according to the choice of the owner 0
0
0
DIV#13 Total cost of this section Carried Forward To Summary 0

14 DIV#14 CONVEYING SYSTEM


0
NA

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1622/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount

DIV#14 Total cost of this section Carried Forward To Summary 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1623/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount

15 DIV#15 DIVISION 15 - MECHANICAL

15.1 DOMESTIC WATER SYSTEM

15.1.1 Pipework
Supplying, installing, connecting and testing PP - R
( poly propylene ) piping systems for 'domestic cold
and hot water service water, complete with but not
limited to including all fittings, sleeves supports,
hanger, inserts, water hummer arrestor and expansion
joints,terminal valves, air relief valves, all Dia. of pipes
inner Dia., for outside exposed pipe thermal insulation
and cladding should be used, all as specified as shown
drawings.. "AQUA THERM, QOBLAN or equivalent as
per owner instructions"
15.1.1.1 20 mm outside diameter pipe LM 0
0
15.1.1.2 25 mm outside diameter pipe LM 0
0
15.1.1.3 32 mm outside diameter pipe LM 0
0
15.1.1.4 40 mm outside diameter pipe LM 0
0
15.1.1.5 50 mm outside diameter pipe LM 0
0
15.1.1.6 63 mm outside diameter pipe LM 0
0
15.1.1.7 80 mm outside diameter pipe LM 0
0
0
Isolation Valves 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1624/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount

Supplying, installing, connecting and testing main


isolating valves (Brass body and stainless steel stem)
0
complete with all accessories and fittings, all as
specified as shown drawings.
0
Gate Valve 0
15.1.1.14 Gate vlave Ø 25 mm 0
15.1.1.15 Gate vlave Ø 32 mm 0
15.1.1.16 Gate vlave Ø 40 mm 0
15.1.1.17 Gate vlave Ø 50 mm 0
15.1.1.18 Gate vlave Ø 90 mm 0
0
0
15.1.2 Electric Water Heaters 0
0
Supply, install, test and commission Electric Water
Heater, horizontal ceiling hung type, glass lined heavy
gauge steel vessel, 20mm CFC-free compact foam
insulation and outer jacketing constructed of aluminum
sheet protected by a plastic film, complete with
magnesium anode and thermostat. installed connected
and tested complete including isolating valves, drain 0
valves, pressure and temperature relief valve, check
valves, supports, electric connections, and accessories,
all as specified and shown on drawings "GMS UK or
equivalent as per owner instructions"

0
15.1.2.2 EWH-2 (50 Liter) No. 0
0
15.1.2.3 EWH-3 (80 Liter ) No. 0
0
15.1.2.4 EWH-4 (100 Liter) No. 0
0
15.1.3 Domestic Cold water tank 0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1625/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# # Amount
Supply Pre-insulated potable water tank, installed,
connected, and tested complete, including concrete
bases, access, vent cowl with vermin screen, overflow
pipe, drain valve, isolating valve, level switches, float 0
switches, electric connections and accessories, all as
specified and shown on the drawings

0
15.1.3.1 WT- ( 8000 L ) No. 0
0
0
15.1.5 Pumps 0
0
SUBMERSIBLE DOMESTIC LIFT PUMP SYSTEMS 0
Supply, install, connect, test and commission sump
pumps complete including but not limited to control
panel, pumps, motors, foot elbows, guide rails, lifting
chains, valves, control panel, level switches, spare
parts, discharge pipe schedule 80, accessories and all 0
ancillary work as specified nd as shown on drawings.

15.1.5.1 LP-1 ( Two pump change over) ( 35 GPM /65 ft) Set 0
0
15.1.6 Domestic Water Booster Set 0
0

431100001.xlsx/B 13~26-Comp/07/26/2019 QS/Baig 1626/2284


Bill of Quantities
AL-SOBAIE RESIDENTIAL COMPLEX @ RIYADH
ISCIPLINES

Secondary GATE

ITEM DIV B20


DESCRIPTION UNIT
# #