Anda di halaman 1dari 2

FOX 512 & FOX 515 Overview

SDH Mapping according G.707


x1 x1
STM-1 AUG AU-4 VC-4 C-4 139264 kbit/s
x3
x1
x3 TUG-3 TU-3 VC-3

AU-3 VC-3 x7 C-3 34368 kbit/s


x7
x1
TUG-2 TU-2 VC-2 C-2 6312 kbit/s
UBUS UNITS SBUS (SDH) Units x3

TU-12 VC-12 C-12


x4 2048 kbit/s

Aggregates
2x155 Mbit/s opt.
SYNIO S1.1
STM-1optical IF L1.1, L1.2
EXLAx G. 957 TU-11 VC-11 C-11 1544 kbit/s

SBUS 2 Segments: Segment 1 Slot 2..9; Segment2 Slot 15..20; 2 x VC4


PAX 2 w a, b 64k OHC VC-4, SETS
Exchange line IF optical: 2 IFs 155 Mbit/s opt. 155 Mbit/s opt.
LHC550
12 ports 155 Mbit/s opt.
SYNIF S1.1 Pointer Processing
STM-1optical IF L1.1, L1.2
2/4 w a, b OHC VC-4, SETS G.957
PAX NEMCA 64k optical: 1 IF Multiplexing
E&M Voice freq. IF 4 x 10/100BaseT Aligning
8 ports 155 Mbit/s
(E'&M') SYNIC G. 703, coaxial Mapping
STM-1 electrical IF 155 Mbit/s AXX155/E
OHC max. 12 x 2 Mbit/s
VC-4, SETS 1+1 C-n Container-n
electrical: 1 IF
64k GECOD
64k 155 Mbit/s opt. 4 x 10/100BaseT
DTE 64 kbit data IF SYNOT S1.1
G.703 155 Mbit/s opt.
8 ports STM-1 optical IF L1.1, L1.2 AXX155/E
VC-4 G. 957 max. 12 x 2 Mbit/s
OHC 1+1

Tributaries
optical: 1 IF
4 x V.24/V.28
(RS232) n x 64k SYNAC SYTEL Optical Port Designations
UNIDA 431 8 x 2 Mbit/s SBUS access SBUS access
4 x V.35 n x 64k VC-12 TU-12 / G.703
34/45 Mbit/s according G.957
UNIDA 432 channels: 8 data: 1 IF A-b.c
4 x X.24/V.11 n x 64k
DTE UNIDA 433
2 x V.36 RS449 32 x VC12 SYNVA SYNAM 1: 1310 nm
n x 64k SBUS access SBUS access 2: 1550 nm
UNIDA 434 8x2 Mbit/s G.703
TU-12 TU-12 / G.703
4 x V.36 RS449 n x 64k channels: 32 data: 8 IFs 1 STM-1
UNIDA 435 4 STM-4
4 x X.24/V.11 n x 64k 16 STM-16
UNIDA 436 SYNAD 64 STM-64
4 x V.35 SBUS access
n x 64k 16x2 Mbit/s G.703 I Intra Office
UNIDA 437 TU-12 / G.703
data: 16 IFs S Shorthaul
4 x X.24/V.11 n x 64k L Longhaul
UNIDA 438 Example:
L-1.2 Longhaul STM-1 1550nm
128k/64k
DTE
X.21/V.11
V.35
V.24/V.28
NTU
2 w a, b
144k
3)
SULIC
Data IF for NTU
64k PBUS UNITS
8 ports
0,6-38,4k 2B1Q
4 x 2 Mbit/s 8 Mbit/s opt. 8 Mbit/s opt.
TUPON TUPON 4 x2 Mbit/s G.703/G.704 Synchronisation Quality Levels
EXLIC/EXLOC
PAX 2 w a, b ISDN-U (2B1Q) 64k OHC Optical/el. IF Optical/el. IF according G.707
4 x2 Mbit/s G.703/G.704
2B1Q Exchange line IF
8 ports QL SDH synchronisation quality level description
8 Mbit/s opt. 0 Quality unknown (Existing Sync. Network)
8 x 2 Mbit/s LOMIF TUNOR 4 x2 Mbit/s G.703/G.704 1 Reserved
SULIS 2 Mbit/s IF 8 x 2 Mbit/s G.703/G.704 Optical/el. IF 2 Rec. G.811
S0 2 w a, b ISDN-U (2B1Q) 64k 8 ports
ISDN NT-1 3 Reserved
Subscr. line IF
PBUS 40 x 2 Mbit/s or 128 x 2 Mbit/s (upgrade possible); VC12

144k 4 Rec. G.812 transit


2B1Q 8 ports
4 x 2 Mbit/s LOMI4 5 Reserved
2 Mbit/s IF 4 x 2 Mbit/s G.703/G.704 6 Reserved
ISBUQ (V5) 4 ports 7 Reserved
S0 2 w a, b ISDN-U (2B1Q) 64k 8 Mbit/s opt. 8 Mbit/s opt. 8 Rec. G.812 local
ISDN NT-1 Subscr. line IF LHC550
9 Reserved
144k
2B1Q 8 ports ETHUB 10 Reserved
UBUS 8 x 2 Mbit/s

Ethernet Hub 5 x 10/100BaseT


11 Synchronous Equipment Timing Source (SETS)
12 Reserved
ISBUT (V5)
S0 2 w a, b ISDN-U (4B3T) 64k 13 Reserved
ISDN NT-1 Subscr. line IF 14 Reserved
144k 2 x 2 Mbit/s 10BaseT
4B3T 8 ports LAWA 4 15 Do not use for synchronization
Ethernet
4 x Teleprotection Commands
TEBIT CAP or 10BaseT Ethernet
8 x Binary Signals 64k 10BaseT MUSIC100 (with 4-port-Hub)
4x Teleprotection 2 x 2 Mbit/s Ethernet 2B1Q
(SOHO desktop) DSL
1 x IRIG 8x Binary LEMU 6
6 x HDSL DSL 1 IF RS 232C
data 1 IF Local management
OPTICAL INTERFACE Bus Structure
10BaseT CAP or LECAR (desktop) 2 Mbit/s G.703/G.704
- FOX 20/6+ 1 x optical n x 64k 2 x 2 Mbit/s LEMQ 6 Ethernet 2B1Q or
OTERM Ethernet: 1 IF DSL transm. Bus Hierarchy Capacity
- NSD 570, NSD 70D 2-Wr. a,b DSL 2 IFs n x 64 kbit/s G.703/G.704
(n=1...20) MSDSL: 6 IFs X.21/V.11 or V.35 or V.36
- REL 316 2B1Q data 1 IF UBUS PDH 8 x 2 Mbit/s
- REL 561 / 551 / 511 / etc. PBUS PDH/SDH 40 x 2 Mbit/s or
8 x 2 /4W HDSL MUSIC200 (LESAR desktop) 2 Mbit/s G.703/G.704 128 x 2 Mbit/s
8 x 2 Mbit/s CAP/2B1Q CAP DSL transm. or
LESA8 n x 64 kbit/s G.703/G.704
DSL 2 IFs SBUS SDH 2 x VC4
data 1 IF X.21/V.11 or V.35 or V.36

2 x 4W HDSL CAP/2B1Q
4 x 2 Mbit/s CAP REGEN CAP
SLIM1 2 x G.703 front access HDSL Regenerator
only once per link

Related products 4 x 2 Mbit/s SLIM2


Power: 2 IFs
2 x 4W HDSL CAP/2B1Q

2 x G.703 front access


UNIDA-Options
Available UNIDA-Options:

LHC550 Integrated Optical Booster/PreAmplifier VU-OPT1: 1+1 protection


8 x 2 Mbit/s PCONV VU-OPT2: point-multipoint communication
V.5x Protocol conv. 2 x 2 Mbit/s G.703/G.704 VU-OPT3: performance monitoring
2 ports VU-OPT4: subrate multiplexer

10 x 2 Mbit/s 3) PCON2
V.5x Protocol conv.

2 x 2 Mbit/s PHL C1 2 w a, b
The LHC550 is a stand-alone unit for long distance 60 ports

optial communication with bit rates from 8 Mbit/s up


to 622 Mbit/s on single optical wavelength. It can
2 Mbit/s PHL C2 2 w a, b
provide an optical power budget of up to 50 dB, 30 ports
which allows transmission distances of optical signals
up to 200 km.
2 Mbit/s PHL C3 2 w a, b
10 ports
AXX155/E Converging TDM & Data Services

Control and Power Units


UNEM (Universal Network Manager)
Redundant COBU < x >
2048 kHz UNEM Basic Package
Cost-efficient, fully SNMP-managed Integrated Ext. clock input (2)
Clock output (3) - Graphical network management
Access Device, that allows combined point-multi- COBU < x > high/low - Configuration management
Ext. alarm input (4)
point connectivity for 2 Mbit/s (G.703 & PRA) and 8 x 2 Mbit/s open/close - Performance management
Alarm relay output (2) - Fault management
10/100BaseT signals via optical or electrical STM-1. UBUS <—> PBUS interconnection
RS232, 1154 kbit/s
Synchronization

}
F-interface - Security management
It supports VLAN as well as QoS features and MIB RS 485 - Supported NE: FOX 515, FOX 512,
Alarm IF Q1-interface
guarantees with its signal and power redundancy Management Communication 10Base T
Qx-interface
UCST FOX-U, FOX-U/M,
concept highest availability. FOX-U/E
8 x 2 Mbit/s
Options: V9VK
UNEM - 4 Element Agent
- COBUV: includes Voice Conference - Scalable Licence-fee available
- 40 or 128 Mbit/s PBUS capacity V9VK 2 x UA, 2 x NA - Various options available,
Alarm Module 4 x ext. Alarms e.g. end to end configuration tool

ALCAR 24 input
24 Alarm Inputs el.
4 Contact Outputs 8 output EXT. ALARMS
4 Serial Ports
max. 5 x ALCAR/FOX el.

–48 VDC DPF


Dual Power Feeder
R1AH 1)
–48 VDC

–48 VDC } Redundant


Power
Feeding

POSUS/POSUM n+1

+/-5 VDC
POSUS/POSUM
–48 VDC Power Converter n≤ 5

230 VAC
+/-5 VDC POSUA2) 115 VAC
AC/DC converter
–48 VDC & Battery Charger

–48 VDC
BATMO 2)
-48 Backup-Battery

1) FOX 515 only


2) FOX 512 only
3) Depends on the V5 protocol type

www.abb.com/utilitycommunications
We reserve all rights in this document and in the information contained therein. This system overview does neither claim completeness nor availability of modules or functions and ABB reserves the right to insert, postpone or remove modules and functions without further notice.
Reproduction, use or disclosure to third parties without express authority is strictly forbidden. © ABB Switzerland Ltd, Utility Automation; 2003
TECHNICAL DATA OF FOX 512 & FOX 515
FOX 515 MAIN CHARACTERISTICS SDH MODULES TELEPHONY MODULES DATA MODULES (continued)
Recommendations SYNIO STM1 optical aggregate EXLAN Analogue exchange interfaces SULIC NTU Baseband modem
ITU-T G.702, G.703, G.704, G.706, G.707, G.711, G.712-G.715, Interface type STM-1 Aggregate ITU-T coding A-law acc. G.711 Interface type: V.24 / V.28 0.6..38.4 kBit/s synch / asynch
G.732, G.735, G.736, G.737,G.742, G.821, G.823, G.826, S1.1 L1.1 L1.2 Characteristics of 2 wire voice channels Q.552 X.21 0.6..38.4 kBit/s asynch
G.957, Q.920, Q.921, Q.922 Wavelength 1310 nm 1310 nm 1550 nm Number of interfaces 12 0.6..128 kBit/s synch
Crossconnect Launched power -10 ± 2 dBm –2 ± 2 dBm -2 ± 2 dBm Nominal impedance Complex V.35 0.6..38.4 kBit/s asynch
DXC Modular non blocking cross connect capacity Minimum sensitivity -38 dBm -38 dBm -38 dBm Channel bandwidth 300..3400 Hz 0.6..128 kBit/s synch
40 x 2Mbit/s with COBUX 137; COBUV145 Attenuation range 24 dB 32 dB 32 dB Signalling, basic functions Seizure, ringing, ringing off, transmission of flash pulses, NTU remote Power Supply 48 V or 96 V
128 x 2Mbit/s with COBUX 237; COBUV146 Number of ports 2 pulse dialling, DTMF without accompanying signal, Number of interfaces: SULIC: 8 x NTU 1
Cross connections at 64 kBit/s, n x 64k Bit/s and 2 Mbit/s Connector type E2000 (type LSH-HRL) earth key, charging using 12/16 kHz pulses Dimensions
Capacity Module width 2 Module width 2 Aluminium Housing 254 x 196 x 42 mm
UBUS 8 x 2 Mbit/s SYNIF STM1 optical aggregate NEMCA NF interfaces with E&M signalling Plastic Housing 165 x 162 x 35 mm
PBUS 40 or 128 x 2 Mbit/s (upgrade 40 -> 128 possible) Interface type STM-1 aggregate ITU-T coding A-law G.711
SBUS 2 x 2 x VC4 S1.1 L1.1 L1.2 Characteristics of voice channels G.712-G.715
FOX-U compatibility Wavelength 1310 nm 1310 nm 1550 nm Channel bandwidth 300..3400 Hz
Launched power ±-10 ± 2 dBm -2 ± 2 dBm -2 ± 2 dBm Number of interfaces 8 ISDN MODULES
Tributary channels Supports up to 240 channels as tributary from UBUS
modules Minimum sensitivity -38 dBm -38 dBm -38 dBm E&M Signalling SULIC
Attenuation range 24 dB 32 dB 32 dB signalling type Type II; Transmission code 2B1Q
Traffic protection Number of ports 1 signalling circuits E, M, E’, M’ Number of timeslots per subscriber 2.5
1+1 protection (n x 64 kBit/s) NEMCA, GECOD SULIC, UNIDA, TEBIT Connector type E2000 (type LSH-HRL) Module width 1 NT-1 remote power supply 96 V
LTP SYNAC, SYTEL Module width 1 Number of Uk0 interfaces 8
SNCP LOMIF, SYNAC Module width 1
MSP SYNIO SYNOT
Interface type STM-1 Tributary, EXLIC
Ambient conditions S1.1 L1.1 L1.2 PSTN MODULES Transmission code 2B1Q
Storage Acc ETSI 300 019-1-1 class 1.2 Wavelength 1310 nm 1310 nm 1550 nm Number of timeslots per subscriber 2.5
PHLC1 Subscriber line interfaces
–25° C..+55° C Launched power –10 ± 2 dBm –2 ± 2 dBm –2 ± 2 dBm NT-1 remote power supply 96 V
ITU-T coding A-law acc. G.711
Transport Minimum sensitivity -38 dBm -38 dBm -38 dBm Number of Uk0 interfaces 8
Characteristics of 2 wire voice channels Q.552
Temperature ranges Acc ETS 300 019-1-2 class 2.2 Attenuation range 24 dB 32 dB 32 dB Module width 1
Number of interfaces 60 ports a/b
–unventilated enclosures –25° C..+70° C Number of ports 1 Nominal impedance Programmable ISBUQ ISDN Basic access U interface 2B1Q
–ventilated enclosures / outdoor –25° C..+40° C Connector type E2000 (type LSH-HRL) Channel bandwidth 300..3400 Hz Number of U interfaces 8
Vibration Module width 1 Modes V5.x, MCAS, carrier adapter, phone-exchange
ASD @ 10..200Hz 1.0 m2s-3
SYNIC Full test for subscriber lines is included Line code 2B1Q
ASD @ 200..2000Hz 0.3 m2s-3
Interface type STM-1 electrical Ring over b-wire Power feeding of NT1 Supported
Operation Acc ETS 300 019-1-3 class 3.2
Number of ports 1 Module width 3 Interoperation with EXLIC Not supported
Temperature range system –5° C..+45° C
Humidity 95% non condensing Code CMI PHLC2 Subscriber line interfaces Interoperation with PCON<X> Supported
Impedance 75 Ω asymmetric ITU-T coding A-law acc. G.711 Leased lines (ISBUQ-ISBUQ) Not supported
Mechanical dimensions signal attenuation 0..12.7 dB @78 MHz Module width 1
Characteristics of 2 wire voice channels Q.552
Subrack with front cover (WxHxD) 482.6 x 308.2 x 303 mm Jitter Acc. G.825 Number of interfaces 30 ports a/b ISBUT
Cable tray (WxHxD) 482.6 x 87.1 x 240 mm Connector type Coaxial, 75 Ω Series 1.6/5.6 ms Nominal impedance Programmable Number of U interfaces 8
Heat deflection shield (WxHxD) 482.6 x 87.8 x 237 mm Module width 1 Channel bandwidth 300..3400 Hz Line code 4B3T
Number of available slots 21 (including 1 or 2 slots for COBU<x>)
SYNAC VC 12 termination Modes V5.x, MCAS, carrier adapter, phone-exchange Power feeding of NT1 Supported
Typetests Capacity 8 x VC12 termination Full test for subscriber lines is included Interoperation with PCON<X> Supported
KEMA Typetest 98430060-tdp 99-1010 Path protection LTP supported Ring over b-wire Leased lines (ISBUT-ISBUT) Supported
Power Supply Module width 1 Module width 2 Module width 1
Voltage -48 VDC (-40.5..-57 VDC) SYNVA PHLC3 Subscriber line interfaces SULIS
-60 VDC (-50.5..-72 VDC) Capacity 32 x VC12 SBUS<->PBUS interconnection ITU-T coding A-law acc. G.711 Transmission code 2B1Q
Dependability Interface type No physical interface Characteristics of 2 wire voice channels Q.552 Number of timeslots per subscriber 2.5
MADT (Mean Accumulated Down Time Module width 1 Number of interfaces 10 ports a/b NT-1 remote power supply 96 V
Traffic between any 2 Mbit/s ports) <10’ per year Nominal impedance Programmable Number of Uk0 interfaces 8
SYNAM Channel bandwidth 300..3400 Hz
MTTF > 20 years per unit Interface Type G.703, Module width 1
Modes V5.x, MCAS, carrier adapter, phone-exchange
Bitrate 2048 kBit/s ± 50 ppm Full test for subscriber lines is included
Line impedance 75 Ω asymmetrical or 120 Ω symmetrical Ring over b-wire
FOX 512 MAIN CHARACTERISTICS Number of interfaces per module 8 Module width 2
Recommendations Traffic protection LTP on VC12 TELEPROTECTION MODULES
ITU-T G.702, G.703, G.704, G.706, G.707, G.711, G.712-G.715, Performance monitoring Acc. G.826 PCONV V5x Protocol converter
OTERM Optical interface
G.732, G.735, G.736, G.737,G.742, G.821, G.823, G.826, Module width 1 Supported protocols V5.1, V5.2
Interface type Complies to IEC 60870-5-1
G.957, Q.920, Q.921, Q.922 Number of E1 interfaces 2 x 2 Mbit/s
SYNAD Format F1.2
V.5.1 interfaces (= links) 4
Crossconnect Interface type G.703, NSD570, NSD70D, FOX6+, FOX20
V.5.2 interfaces 1
DXC Modular non blocking cross connect capacity Bitrate 2048 kBit/s ± 50 ppm REL316, REL551, REL561, etc.
V.5.2 link 2
40 x 2 Mbit/s with COBUX 137; COBUV145 Line impedance 75 Ω asymmetrical or 120 Ω symmetrical PSTN user ports 240
Number of interfaces 1 Optical (1300 nm)
128 x 2 Mbit/s with COBUX 237; COBUV146 Number of interfaces per module 16 1 RS232 (FOX6+ compatible)
ISDN-BA user ports 112 including
Cross connections at 64kBit/s, n x 64 kBit/s and 2 Mbit/s Traffic protection LTP on VC12 Optical code MCMI
- processing of p- and f-data
Capacity Performance monitoring Acc. G.826 Module width 1
- digital leased lines
UBUS 8 x 2 Mbit/s Module width 1 Module width 1 TEBIT Teleprotection interface
PBUS 40 or 128 x 2 Mbit/s (upgrade 40->128 possible) SYTEL Teleprotection Complies to IEC 60834 -1
SBUS 2 x 2 x VC4 PCON2 V5x Protocol converter
Interface type 34/45 Mbit/s tributary interface Voltage range 24..250 VDC
Supported protocols V5.1, V5.2
FOX-U compatibility Line impedance - Propagation delay time Typ. 3.5 ms (optimised for speed, 24..125 V)
Number of E1 interfaces 2 x 2 Mbit/s
Tributary channels Supports up to 240 channels as tributary from UBUS Number of interfaces per module 1 1+1 switch over time Typ. 3.5 ms
V.5.1 interfaces (= links) 10 Number of interfaces 4 independent commands
modules Traffic protection LTP
V.5.2 interfaces 1
Module width 1
Traffic protection V.5.2 links 8 Binary
1+1 protection (n x 64kBit/s) NEMCA, GECOD SULIC, UNIDA, TEBIT PSTN user ports 480 Voltage range 24..60 VDC
LTP SYNAC, SYTEL PDH OPTICAL MODULES ISDN-BA user ports 224 including Number of interfaces 8 Binary contacts
SNCP LOMIF, SYNAC TUPON 8448 kBit/s optical interface - processing of p- and f-data IEC standard Complies to IEC 60834 -3
MSP (Multiplex Section Protection) SYNIO Interface type 8 Mbit/s PDH - digital leased lines Module width 1
Wavelength 1300 nm 1500 nm Module width 1
Ambient conditions
Storage Acc ETSI 300 019-1-1 class 1.2 Launched power –10 ± 2 dBm –2 ± 2 dBm
Minimum sensitivity –40 dBm –40 dBm
–25° C..+55° C
Attenuation range 26 dB 34 dB
Transport ELEMENT MANAGER
Number of ports 1 Ethernet / TCP/IP MODULES
Temperature ranges Acc ETS 300 019-1-2 class 2.2 UCST
Connector type E2000 (type LSH-HRL)
–unventilated enclosures –25° C..+70° C LAWA4 UCST R4E and higher Element manager for local as well as remote
Optical code MCMI + telemetry
–ventilated enclosures / outdoor –25° C..+40° C Interface type Ethernet 10BaseT configuration of FOX-U and FOX 515
Number of electrical ports 4
Vibration Number of interfaces 1 Supported platforms UCST R4: Windows 95,98,NT
Interface type G.703
ASD @ 10..200Hz 1.0 m2s-3 Routing protocol OSPF V2 UCST R5: Windows 98, NT, ME & 2000
Module width 1
ASD @ 200..2000Hz 0.3 m2s-3 Additional features Layer 2 or 3 IP concentration Supported NE FOX 515, FOX 512, FOX-U, FOX-U/M
Operation Acc ETS 300 019-1-3 class 3.2 TUNOR 8448 kBit/s optical desktop Frame Relay FRAD functionality
Temperature range system (extended) –20° C..+55° C Multiplexing procedure G.742 Static routing
with old UBUS units –10° C .. +55° C Transmission code MCMI + telemetry Support of VLAN (port based, TDM or IEEE 802.1q)
Start up temperature –20° C Allowed fibre attenuation Up to 20 dB (approx. 30 km) PBUS / router capacity 2 x 2 Mbit/s
with old UBUS units –5° C Optical wavelength 1300 nm Bridges up to 7 NETWORK MANAGEMENT
Humidity 95% non condensing Number of optical ports 1 Module width 1 UNEM
Connector type FC/PC UNEM Network manager with graphical display for element and
Mechanical dimensions ETHUB
Number of electrical ports 4 network
Subrack with front cover (W x H x D) 482.6 x 177x 283 mm Interface type Ethernet 10/100BaseT
Interface type G.703 Supported NE FOX 515, FOX 512, FOX-U, FOX-U/M
Number of available slots 8 Number of interfaces 5
Module width 1
Power Supply Module width 1
Voltage -48 VDC (-40.5..-57 VDC) PDH ELECTRICAL MODULES LEMU6
–60 VDC (–50.5..-72 VDC) (see HDSL Modules) (see HDSL Modules)
With POSUA: 115 VAC (88 VAC 132 VAC) LOMIF 2 Mbit/s electrical interface:
With POSUA: 230 VAC (176 VAC 264 VAC) Interface type G.703,
Bitrate 2048 kBit/s ± 50 ppm
Power Consumption Line impedance 75 Ω asymmetrical or 120 Ω symmetrical
Max Power Consumption Number of interfaces per module 8 DATA MODULES
- -48 VDC 144 W Traffic protection Subnetwork connection protection at 2 Mbit/s GECOD 64 kBit/s G.703 codirectional
- -60 VDC 180 W RELATED PRODUCTS
Performance monitoring Acc. G.826 ITU-T recommendation G.703
– Mains Power Interface 180 W Module width 1 Bit rate 64 kBit/s codirectional LHC550 Integrated Optical
Dependability Number of interfaces 8 Booser / PreAmplifier
LOMI4 2 Mbit/s electrical interface Optical Output Power +10 dBm
MTTF > 20 years per unit Interface type G.703, Module width 1
Optical Receiver Power – 40 dBm
Bitrate 2048 kBit/s ± 50 ppm UNIDA 431 Data interfaces n x 64 kBit/s
Optical connectors E2000 APC
Line impedance 75 Ω asymmetrical or 120 Ω symmetrical Interface type V.24 / V.28, RS232
Type of fibre SM Fibre ITU-T G.652/654/655
Number of interfaces per module 4 Bitrate 0..0.3 kBit/s transp (V.110)
BASIC MODULES Management Interface LAN/RJ45
Traffic protection Subnetwork connection protection at 2 Mbit/s 48, 56, n x 64 kBit/s (n=1..31) synch (V.110)
Performance monitoring Acc. G.826 Options 1+1, Alarm-output
COBUX Control unit Power Supply dual -48VDC, max. 30W
Network management interfaces Qx – interface 10BaseT IEEE 802.3 Module width 1 Subrate multiplexing,
Point-Multipoint EMC EN55022 ClassB
Q1 – interface RS 485
Number of interfaces 4 Safety EN60950
F- interface V24/V28 (RS 232) HDSL MODULES
4 Alarms input, 2 Alarm relay output Module width 1
LEMU6 HDSL module for SOHO
2 synchronisation inputs, 3 synchronisation outputs Number of DSL interfaces 6 x 1 pair UNIDA 432 Data interfaces n x 64 kBit/s
Features TCP/IP tunnelling, ECC, diagnostics Interface type V.35 AXX155/E Integrated Access Device
Line code CAP
Options 1+1 equipment protection Bitrate 0.6..38.4 synch / asynch (V.110) 2 Mbit/s 120 Ω TDM Interfaces max. 12 ports
Line bit rates 128..2048 kBit/s
Module width 1 48, 56, n x 64 kBit/s (n=1..31) synch (V.110) acc. G.703 & ISDN/PRA
Transmission range Up to 16 km
COBUV Control unit with conference Performance monitoring Acc. G.826 Options 1+1, 10/100BaseT Data Interfaces 4 Ports switched/routed
Network management interfaces Qx – interface 10BaseT IEEE 802.3 Additional features Bridging, with diverse sub modes Subrate multiplexing, acc. IEEE 802.3
Q1 – interface RS 485 IP static routing Point-Multipoint, WAN-Port 1+0 / 1+1 155 Mbit/s electrical G.703 or
F- interface V24/V28 (RS 232) IP OSPF V2 dynamic routing Performance monitoring 1+0 / 1+1 155 Mbit/s optical S1.1
4 Alarms input, 2 Alarm relay output Unnumbered IP links on DSL and PBUS interfaces Number of interfaces 4 Management Interfaces (SNMP based) LAN / RS232 / remote via DCC or In-band
2 synchronisation inputs, 3 synchronisation outputs Frame relay FRAD functionality Module width 1 Alarm-in/out & Test-connector
Features TCP/IP tunnelling, ECC, diagnostics DHCP relay configurable for SOHO UNIDA 433 Data interfaces n x 64 kBit/s Power Supply 230VAC / dual -48VDC; max. 20 Watt
Options 1+1 equipment protection IP managed bridge configurable for SOHO Interface type X.24 / V.11 EMC EN55022 ClassB / EN50082.1
Module width 1 Module width 1 Bitrate 0.6..38.4 synch / asynch (X.30) Safety EN60950 / EN60825
Voice conference (partyline) Possible conferences: max. 21 LEMQ6 HDSL module for SOHO 48, 56, n x 64 kBit/s (n=1..31) synch (X.30)
Possible conference parties: max. 64 Number of DSL interfaces 6 x 1 pair Options 1+1,
V9VK Alarm module Line code 2B1Q Subrate multiplexing,
Alarm output duplication UA: 2 Line bit rates 128..2048 kBit/s Point-Multipoint,
NA: 2 Transmission range Up to 16 km Performance monitoring
Performance monitoring Acc. G.826 Number of interfaces 4
ALCAR Alarm interface Module width 1 Abbreviations
Interfaces 24 Alarm inputs Additional features Bridging, with diverse sub modes
4 Binary outputs IP static routing UNIDA 434 Data interfaces n x 64 kBit/s
4 serial interfaces IP OSPF V2 dynamic routing Interface type V.36 RS-449 CAP Carrierless Amplitude and Phase
Maximum number of modules per FOX 5 Unnumbered IP links on DSL and PBUS interfaces Bitrate 0.6..38.4 synch / asynch (V.110) CMI Code Mark Inversion
Module width 1 Frame Relay FRAD functionality 48, 56, n x 64 kBit/s (n=1..31) synch (V.110) DSL Digital Subscriber Line
DHCP relay configurable for SOHO Options 1+1, DXC Digital Cross Connect
POSUS Power supply IP managed bridge configurable for SOHO Subrate multiplexing, ECC Embedded Communication Channel
Internal supply voltage 5V Module width 1 Point-Multipoint, HDSL High Bitrate Data Subscriber Line
Supplied power 50 W Performance monitoring LTP Line Trail Protection
Module width 1 LESA8
Number of DSL interfaces 8 x 1pair or 4 x 2 pair Number of interfaces 2 MCAS Mercury Channel Associated Signalling
POSUM Power supply Line code CAP, 2B1Q, PAM16, G.SHDSL Module width 1 MCMI Multi Code Mark Inversion
Internal supply voltage 5V Line bit rates 2 x 1168 or 1 x 2048 kBit/s UNIDA 435 Data interfaces n x 64 kBit/s MIB Management Information Base
Supplied power 85 W Transmission range Up to 16 km Interface type V.36 RS-449 MSP Multiplex Section Protection
Module width 1 Transmission mode 1pair, 2pair or mixed Bitrate (circuits 140,141,142 not supported -> use UNIDA434) NA Non Urgent Alarm
Dual power feeder (FOX 515 only) Performance monitoring Acc. G.826 0.6..38.4 synch / asynch (V.110) NE Network Element
Number of power sources 2 Remote powering Not supported 48, 56, n x 64 kBit/s (n=1..31) synch (V.110) OHC Overhaed Channel
Feeding voltage 48 VDC Module width 1 Options 1+1, OSPF Open Shortest Path First
POSUA (FOX 512 only) SLIM1 Subrate multiplexing, PDH Plesichronous Digital Hierarchy
Nominal input voltage 115 VAC (88 VAC 132 VAC) Number of DSL interfaces 2 x 1 pair or 2 x 2pair Point-Multipoint, SDH Synchronous Digital Hierarchy
220 VAC (176 VAC 264 VAC) Line code CAP, 2B1Q, PAM16 Performance monitoring SETS Synchronous Equipment Timing Source
Frequency 45..63 Hz Line bit rates 2 x 1168 or 1 x 2048 kBit/s Number of interfaces 4 SNCP Sub-Network Connection Protection
Max. converted power 140 W Transmission range Up to 16 km Module width 1 STM Synchronous Transport Module
Max. consumed power 180 W Transmission mode 1pair, 2pair or mixed UNIDA 436 UA Urgent Alarm
Charger interface (battery connected) Number of G.703 interfaces 2 x E1/G.703 Interface type X.24 / V.11 VC Virtual Container
nominal voltage @ 20° C: -54.6 VDC Performance monitoring Acc. G.826 Bitrate 0.6..38.4 synch / asynch (X.30)
temperature Remote powering Not supported 48, 56, n x 64 kBit/s (n=1..31) synch (X.30)
compensation (-10° C +50° C) +72 mV/° C Module width 1 Options 1+1, www.abb.com/utilitycommunications
deviation of compensated voltage <2% SLIM2 Point-Multipoint,
Module width 2 Number of DSL interfaces 2 x 1 pair or 2 x 2pair Performance monitoring
Line code CAP, 2B1Q, PAM16 Number of interfaces 4
BATMO DC Battery backup interface (FOX 512 only)
Line bit rates 2 x 1168 or 1 x 2048 kBit/s Module width 1
Interface Access POSUA
Transmission range Up to 16 km UNIDA 437
FANUV (FOX 512 only)
Transmission mode 1pair, 2pair or mixed Interface type V.35
Number of FANs 2
Number of G.703 interfaces 2 x E1/G.703 Bitrate 0.6..38.4 synch / asynch (V.110)
Operation temperature controlled
Performance monitoring Acc. G.826 48, 56, n x 64 kBit/s (n=1..31) synch (V.110)
(<30° C low speed/>50° C high speed)
Remote powering Supported on two ports (2pair mode) Options 1+1,
Installation Does not require a “Unit”-Slot
Module width 1 Point-Multipoint,
LECAR HDSL modem Performance monitoring
Number of interfaces 4
Printed in Switzerland

Interfaces G.703 / G.704; X.21 / V.11,


V.35, V.36, Module width 1
LAN 1 x 10BaseT (with bridge IEEE 802.1d / router) UNIDA 438
Line code CAP Interface type X.24 / V.11 (with scrambler)
Dimensions 240 x 42 x 280 mm Bitrate 0.6..38.4 synch / asynch (X.30)
MUSIC 100 (SOHO) HDSL modem 48, 56, n x 64 kBit/s (n=1..31) synch (X.30)
Interfaces LAN 4 x 10BaseT (with bridge IEEE 802.1d / Router) Options Point-Multipoint,
WAN interface Cc. Q.920, Q.921, Q.922 Performance Monitoring
11.03

Number of interfaces 4
MUSIC 200 (LESAR) HDSL modem Module width 1
Interfaces 2DSL ports
1 fixed G.703 75 Ω /120 Ω or 1 modular interface
1500

(G.703/75 Ω , V.11/X.21, V.35, V.36, 10BaseT)


Line code CAP, 2B1Q, PAM16, G.SHDSL
1KHA - 000 744 - SEN

Transmission mode 1 and 2 pair service


VC12 to the desktop Supported
Remote powering Not suported
Local power supply AC or DC supported
REGEN HDSL regenerator
Interfaces 2DSL ports
Line code CAP
Transmission mode 2 pair service
Remote powering Suported
Local power supply DC supported

We reserve all rights in this document and in the information contained therein. This system overview does neither claim completeness nor availability of modules or functions and ABB reserves the right to
insert, postpone or remove modules and functions without further notice.
Reproduction, use or disclosure to third parties without express authority is strictly forbidden. © ABB Switzerland Ltd, Utility Automation; 2002