Safety rules

for electric motors

0398 EN 201 384 84 720 IS 910 1


Safety rules

Important. Read these safety rules and 6. Protective measures.


operating instructions with great care Before start-up, care must be taken
before using the motor. that an additional protective meas-
ure to VDE 0100 has been taken.
1. These motors should only be in- There is a terminal for the protective
stalled, adjusted and maintained by conductor marked to DIN 40011
qualified personnel who are aware of inside the terminal box.
the method of operation of the mo- An external earthing terminal can be
tors and the related dangers. Failure fitted on request (against extra
to observe these safety rules may charge).
result in personal injuries. In the case of protective earthing,
the earthing terminal must have
2. The user has to provide for correct
been connected.
earthing of the motor before start-
If several protective measures are
up. The motor should only be oper-
used, these must not render each
ated with the appropriate isolating
other ineffective.
devices with circuit breakers or
other safety devices. Mannesmann 7. Connections should be carried out
Dematic is neither responsible for by qualified personnel (VDE 0105) in
earthing nor for the supply and accordance with local regulations or
fitting of this peripheral equipment. to VDE 0100 (specification for the
installation of power plants with line
3. The user must ensure that the
voltages of up to 1000 V).
driven machines in the entire instal-
lation function perfectly even if they 8. Motors must not be operated with
are not supplied by Mannesmann an open terminal box.
Dematic.
9. The rated voltage indicated on the
4. Dangerous high voltage. motor must be strictly observed.
Motors are connected to a danger-
ous supply voltage. The projecting 10. When three-phase brake motors
parts of these motors may carry a start up, the brake is released and
hazardous voltage when mainte- the shaft is axially displaced.
nance work is being carried out.
Disconnect from the supply before 11. If the motor fan cover features IP 20
working on motors, i.e. when test- protection, objects (screwdrivers, for
ing motors or when maintenance example) should not be introduced
jobs have to be carried out. into the venting grid since a metal
fan rotates inside the motor during
5. Rotating machines and parts of operation.
these machines as well as electric
voltages can be dangerous. There- 12. Brake motors must not be operated
fore we strongly recommend you when the fan cover has been re-
follow the national and local regula- moved.
tions when working on electric ma-
chines and equipment.
Motors should only be installed,
fitted and maintained by qualified
personnel.

Mannesmann Dematic AG Mannesmann Dematic Ltd.


P.O. Box 67, D-58286 Wetter Beaumont Road
Telephone (+49 2335) 92-0, Telefax (+49 2335) 927676 Banbury, Oxon OX16 7QZ