MT4Y/MT4W Series

▣Features
lSuper version of panel meter
lVarious output options
(Basic specification: Indication type)
Communication output, Serial output, BCD output,
NPN/PNP open collector output, Relay output
lMax. measuring input specification
500VDC / 500VAC / 5ADC/ 5AAC
lMax. display range : -1999 ~ 9999
lHigh/Low scale function
lMonitoring function of Max. or Min. display value
lDisplay cycle delay function
lError correction function(High/Low display)
lWide range of power voltage specification
: 100-240VAC

Please read "Caution for your safety" in operation


! manual before using.

▣Ordering information
MT 4 W DV 4 N
N Indication type(No output function)
1 NPN open collector output
2 PNP open collector output
Y Type
3 BCD Dynamic output
4 Current(4-20mADC) output
5 Low speed serial output
6 RS485 output
Output ※Output(1~6) : Option

N Indication type(No output function)


0 Relay contact output+Current(4-20mADC) output
1 Relay contact output
2 NPN open collector output+BCD output
3 PNP open collector output+BCD output
W Type
4 NPN open collector output+Current(4-20mA) output
5 PNP open collector output+Current(4-20mA) output
6 NPN open collector output+Low speed serial output
7 PNP open collector output+Low speed serial output
8 NPN open collector output+RS485 output
9 PNP open collector output+RS485 output
※Output(0~9) : Option
Power supply
4 100-240VAC

DV DC Volt
Measuring input DA DC Ampere
AV AC Volt
AA AC Ampere

Size Y DIN Size W72×H36mm


W DIN Size W96×H48mm
Digit
4 4digits

MT Multi Meter
※When need to measure over 5ADC, please select DV type because shunt should be used.
※MT4Y Type is coming soon.

E-15
Multi Panel Meter
▣Specifications
Series MT4Y MT4W (A)
Counter
Measurement function VDC/ADC, VAC/AAC
Power supply 100-240VAC 50/60Hz(90 ~ 110% of rated voltage)
Power consumption 5VA
(B)
Display method 7Segment LED Display(Red)(Character height:14.2mm) Timer
DC type: FU S ±0.1% Rdg ±2digit
Display accuracy (No te1)
AC type: FU S ±0.3% Rdg ±3digit }23℃ ±5℃ 35~85%Rh
A/D conversion method Dual slope integral method (C)
Sampling cycle 100ms(Resolution 1/12000) Temp.
controlle
Max. indication -1999 ~ 9999(4digit)
Max. input 150% for each input specification(At AC400V:120%)
U Contact capacity : 250VAC 3A, 30VDC 3A (D)
Relay output Power
U Relay contact : N.O(1a)
controlle
Main NPN open
output collector output
12-24VDC ±2V 50mA Max. (Resistive load)
PNP open
(E)
collector output Panel
meter
RS485 commu- U Transmission:1200/2400/4800/9600bps U Transmission method:2wires half duplex
Sub nication output U Transmission code:ASCⅡ Code(7Bit) U Synchronization method:Start-stop synchronization
output
(Trans- Serial output (F)
NPN open collector output, 12-24VDC Max. 50mA (Resistive load) Tacho/
mission BCD output Speed/
output) Pulse
4-20mA output Resolution: 8000 division(Load resistance max. 600Ω) meter
AC measuring method Selectable RMS or AVG
Hold function Built-in(Outer hold function) (G)
Display
Insulation resistance Min. 100MΩ(at 500VDC) between external terminal and case unit
Dielectric stength 2000VAC for 1minute between external terminal and case
Noise stength ±2kV the square wave noise(pulse width:1㎲) by the noise simulator
(H)
Mechanical 0.75mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 2hours Sensor
Vibration controlle
Malfunction 0.5mm amplitude at frequency of 10 ~ 55Hz in each of X, Y, Z directions for 10minutes
Mechanical 100m/s²(10G) in X, Y, Z directions for 3 times
Shock
Malfunction 300m/s²(30G) in X, Y, Z directions for 3 times (I)
Proximit
Relay Malfunction Min. 20,000,000 times sensor
life cycle Mechanical Min. 100,000 times(250VAC 3A Load current)
Ambient temperature -10 ~ +50℃(at non-freezing status)
(J)
Storage temperature -20 ~ +60℃(at non-freezing status) Photo
electri c
Ambient humidity 35 ~ 85%RH sensor
Weight Approx. 134g Approx. 211g
Approval
(K)
Pressur
※(Note1) DC/AC type FU S ±0.3% Rdg ±2digit(0 to +50℃), DC/AC type FU S ±0.5% Rdg ±3digit(-10 to 0℃) sensor

▣Front panel identification


lMT4Y Series lMT4W Series (L)
Rotary
HI
DI GI TAL M ULTI M ETER encoder
1
1 DIGITAL MULTI METER
HI
2 GO
6 (M)
2 GO
6 3 LO 5-Phase
stepping
LO
motor &
MD
3 MD
MT4W Driver &
M T4Y Controlle

4 5 4 5
1 HI : High output indication of preset
4 MD key : Enter to paramneter group, Memorize the setting value,
2 GO : GO output indication of preset Move the parameter mode
3 LO : Low output indication of preset
5 ◀ key : Move the digit, Enter to parameter group
▼ , ▲ key : Change the setting value.
6 Unit
※MT4Y-4N, MT4W-4N type, there is no 1 , 2 , 3 in display panel.

E-16
MT4Y/MT4W Series
▣Connections
◎MT4Y Series(Indication type)
lMT4Y-DV-4N lMT4Y-AV-4N

1 2 3 4 5 6 7 1 2 3 4 5 6 7
50mVDC 5VAC
~ ! ~
5V/1VDC ! 50VAC
50V/10VDC SOURCE ! 110VAC SOURCE !
! 100-240VAC ! 100-240VAC
500V/100VDC 500VAC
COM 50/60Hz COM 50/60Hz

lMT4Y-DA-4N lMT4Y-AA-4N
1 2 3 4 5 6 7 1 2 3 4 5 6 7
2mADC 50mAAC
4-20mADC/ ~ 500mAAC ~
20mADC SOURCE ! SOURCE !
1AAC
500mADC 100-240VAC 100-240VAC
5ADC 5AAC
50/60Hz COM 50/60Hz
COM

◎MT4Y Series(Preset output)


lMT4Y-□□-41(NPN open collector output) lMT4Y-□□-42(PNP open collector output)

2 4 6 8 10 2 4 6 8 10
MAIN OUT: GO MAIN OUT: GO
NPN OPEN COLLECTOR PNP OPEN COLLECTOR
12-24VDC Max. 50mA HI LO 12-24VDC Max. 50mA COM LO
COM HI

1 3 5 7 9 1 3 5 7 9

◎MT4Y Series(Sub output)


lMT4Y-□□-43(BCD output) lMT4Y-□□-44(Current output)
2 4 6 8 10 2 4 6 8 10
BCD OUT: A C D0 D2 Current OUT: +
NPN OPEN COLLECTOR 4-20mADC
12-24VDC Max. 50mA Load 600Ω Max.
B D D1 D3
COM -
1 3 5 7 9 1 3 5 7 9

lMT4Y-□□-45(Low speed serial output) lMT4Y-□□-46(RS485 output)


2 4 6 8 10
2 4 6 8 10
Serial OUT: CLOCK LA TC H
B(-) SG
NPN OPEN COLLECTOR
12-24VDC Max. 50mA COM DATA POL
A(+) SG
1 3 5 7 9
1 3 5 7 9
※ POL:Where display value is "-", outputs the signal of "-".

◎MT4W Series(Indication type)


lMT4W-DV-4N lMT4W-AV-4N

1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9

50mVDC 5VAC
~ !
5V/1VDC 50VAC ~
! SOURCE !
HOLD 110VAC ! S OURCE
50V/10VDC 100-240VAC 50/60Hz HOLD
! ! 100-240VAC 50/60Hz
500V/100VDC 500VAC
COM COM

lMT4W-DA-4N lMT4W-AA-4N

1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9
2mADC 50mAAC
4-20mADC/ ~ ~
20mADC 500mAAC
! SOURCE ! SOURCE
500mADC HOLD 100-240VAC 50/60Hz 1AAC HOLD 100-240VAC 50/60Hz
5ADC 5AAC
COM COM

E-17
Multi Panel Meter
◎MT4WSeries (Preset output + Sub output)
(A)
lMT4W-□□-40 (Relay contact output+Current output) lMT4W-□□-41 (Relay contact output) Counter

MAIN OUT MAIN OUT


CONTACT OUT CONTACT OUT
:250VAC 3A 1a RESISTIVE LOAD :250VAC 3A 1a RESISTIVE LOAD
(B)
Timer
10 11 12 13 14 15 10 11 12 13 14 15
+ -
DC4-20mA
Load 600Ω Max. HI GO LO
(C)
HI GO LO COM
Temp.
controlle
1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9

(D)
Power
controlle

lMT4W-□□-42 / MT4W-□□-43 (NPN/PNP open collector output+BCD output)

(E)
Panel
2 4 6 8 10 12 14 16 18 20 2 4 6 8 meter
+24VDC B D D1 D3 DOT COM2 +24VDC
GO GO 30mA Max.
MAIN OUT : 30mA Max. BCD OUT : MAIN OUT :
NPN OPEN COLLECTOR NPN OPEN COLLECTOR PNP OPEN COLLECTOR (F)
12-24VDC Max. 50mA 12-24VDC Max. 50mA 12-24VDC Max. 50mA Tacho/
0V Speed/
COM1 HI LO 0V A C D0 D2 POL COM1 HI LO Pulse
1 3 5 7 9 11 13 15 17 19 1 3 5 7 meter

※POL:When display value is "-", it where will be changed from High to Low.
(G)
Display
unit
lMT4W-□□-44/ MT4W-□□-45 (NPN/PNP open collector output+Current output)

(H)
2 4 6 8 10 12 14 16 18 20 2 4 6 8 Sensor

GO
+24VDC - GO
+24VDC
30mA Max.
controlle
MAIN OUT : 30mA Max. Current outut: MAIN OUT :
NPN OPEN COLLECTOR 4-20mADC PNP OPEN COLLECTOR
12-24VDC Max. 50mA LOAD 600Ω Max. 12-24VDC Max. 50mA
(I)
COM HI LO + COM HI LO Proximit
1 3 5 7 9 11 13 15 17 19 1 3 5 7 sensor

0V 0V

(J)
Photo
lMT4W-□□-46/ MT4W-□□-47 (NPN/PNP open collector output+Low speed serial output) electri c
sensor

2 4 6 8 10 12 14 16 18 20 2 4 6 8 (K)
Pressur
+24VDC POL CLOCK LATCH +24VDC
GO 30mA Max. SERIAL OUT : GO 30mA Max. sensor
MAIN OUT : MAIN OUT :
NPN OPEN COLLECTOR NPN OPEN COLLECTOR PNP OPEN COLLECTOR
12-24VDC Max. 50mA 12-24VDC Max. 50mA 12-24VDC Max. 50mA
COM1 HI LO 0V COM2 DATA COM1 HI LO 0V (L)
1 3 5 7 9 11 13 15 17 19 1 3 5 7 Rotary
encoder

※POL:When display value is "-", it where will be changed from High to Low.
(M)
5-Phase
stepping
lMT4W-□□-48/ MT4W-□□-49 (NPN/PNP open collector output+RS485 output) motor &
Driver &
Controlle

2 4 6 8 10 12 14 16 18 20 2 4 6 8
+24VDC B(-) SG +24VDC
GO GO 30mA Max.
30mA Max.
MAIN OUT : MAIN OUT :
NPN OPEN COLLECTOR RS485 PNP OPEN COLLECTOR
12-24VDC Max. 50mA 12-24VDC Max. 50mA
COM HI LO 0V A(+) SG LO 0V
COM HI
1 3 5 7 9 11 13 15 17 19 1 3 5 7

E-18
MT4Y/MT4W Series
▣Dimensions
Unit:mm

lMT4Y-3 3 -4N(Indication type) lMT4Y-3 3 -4N


MT4Y-3 3 -43~46(Sub output type) lPanel cut-out
106
85 Min. 91
6 88 12
72
+0.6
DIGIT AL MULT I M ET ER 33 -0

M in. 40 +0. 7
68 -0
MD
MT4Y

lMT4Y-3 3 -41~42(Preset type) lMT4Y-3 3 -41~46


DIGITAL M ULTI M ETER 110
HI

GO 6 88 16
LO

MD
MT4Y

※ Hirose Connet:HIF3BD-10PA-2.54DS

lMT4W-3 3 -4N(Indication type) lMT4W-3 3 -4N, MT4W-3 3 -40, 41 lPanel cut-out


109 106 M in. 116
Relay contact
96 6 89.5 10.5 output terminal

45 +0.6
-0
D IG ITAL MULT I M ETE R
M in. 52.0 +0.8
92 -0

MD
M T4 W

※There is no Relay contact output terminal


lMT4W-3 3 -40~49 block in indication type.

HI
DIG IT AL MULT I ME TER

GO
lMT4W-3 3 -42~49
110.4
LO
20pin Hirose Connet
MD 6 89.5 14.9 (Transistor output + Sub output)
M T4 W

※Hirose Connet:HIF3BA-20PA-2.54DS

▣Parameter setting

RUN

MD ※If pressing MD key for 3sec. in RUN mode, PA1(Parameter 1) is displayed.


※If pressing MD key for 4sec. in RUN mode, PA2(Parameter 2) will be displayed after PA1.
PA 1 ※If pressing MD key for continuosly, PA1 and PA2 are displayed repeatealy.
※When releasing MD key at displaying PA1 or PA2, then enter into Parameter.
※After displaying PA1 or PA2 for 2 sec. then enter into the first mode of Parameter.
(Refer the parameter description for setting)
PA 2

E-19
Multi Panel Meter
▣PARAMETER 1 group
(A)
Counter
RUN
Press MD key for 3sec.

(B)
PA1 Timer

Move after 2sec.

When meas ure AC, select [A verage value(AVG)/Effective value(RMS)].


※It will display only AC type. (C)
MD
Temp.
controlle

MD
Measuring input lMeasuring input chart by model
Select measuring input specification
Indicate Factor y Item Range of measuring input
MD default set ting ▼ ▲ : Measuring input specification (D)
MD MT4Y/W-DV Power
☞ S ee specification chart of measuring input by each item. controlle
MT4Y/W-DA
MT4Y/W-AV
MT4Y/W-AA
(E)
※(☆)Standard specification.(110P is 440VAC/110VAC P.T) Panel
meter
S elect the display method of
measurement input lSpecification and range chart
MD
Select Standard[ ] Prescale[ ]
Measuring input Input Display range (F)
MD Type Display range
[Display] impedance Tacho/
S et the display method against measuring input (Fixed) (Variable)
Speed/
and select whet her it displays measuring input [ ] 0-500V 5.2MΩ 0.0~500.0 Pulse
as 1:1(Standard) or change of it. [ ] 0-100V 5.2MΩ 0.0~100.0 meter
☞ See input specification and range chart [ ] 0-50V 520kΩ 0.00~50.00
select DV [ ] 0-10V 520kΩ 0.00~10.00
(G)
select Type [ ] 0-5V 52kΩ 0.000~5.000 Display
[ ] 0-1V 52kΩ 0.000~1.000 unit
It shows Max. [ ] 0-50mV 10kΩ 0.00~50.00 -1999 ~ 9999
display value Display the Max.
display value [ ] 0-5A 0.01Ω 0.000~5.000 -199.9 ~ 999.9
of standard MD
[ ] 0-500mA 0.1Ω 0.0~500.0 -19.99 ~ 99.99
MD specification. MD See display value against (H)
DA [ ] 0-20mA 2.5Ω 0.00~20.00 -1.999 ~ 9.999
Display value Max. measuring input Sensor
is fixed. : Change the setting Type 4-20mA 2.5Ω 4.00~20.00 (Display point controlle
value [ ] 0-2mA 25Ω 0.000~2.000 will be different
[ ] 0-500V 5.5MΩ 0.0~500.0 according to
decimal point
Display the M in. AV [ ] 0-110V 1.2MΩ 0.0~440.0 position.) (I)
display value Type [ ] 0-50V 550kΩ 0.00~50.00
MD Proximit
MD See display value against [ ] 0-5V 52kΩ 0.000~5.000 sensor
Max. measuring input [ ] 0-5A 0.01Ω 0.000~5.000
: Change the setting AA [ ] 0-1A 0.05Ω 0.000~1.000
value Type [ ] 0-500mA 0.0~500.0 (J)
0.1Ω
[ ] 0-50mA 0.00~50.00 Photo
1Ω
electri c
Display t he Dot position sensor
MD

MD Select the Dot position

Select
(K)
Pressur
sensor
It compens ates a gradient of High-limit display value against Max. input.
MD The setting range is 0.100 to 5.00(%).
MD
(L)
Rotary
It corrects deviation of Low-limit display value against Min.input. encoder

MD Setting range is -99 to +99.


MD
(M)
5-Phase
※After setting each mode, press MD Key for 2 sec. to return to RUN. stepping
motor &
※If no key touched for 60sec. after enter into PARAMETER, it will return to RUN. Driver &
Controlle

▣Factory defaulf setting


Mode MT4Y/W-DV MT4Y/W-DA MT4Y/W-AV MT4Y/W-AA Mode MT4Y/W-DV MT4Y/W-DA MT4Y/W-AV MT4Y/W-AA

E-20
MT4Y/MT4W Series
▣PARAMETER 2 group
RUN
Press MD key for 3sec.

PA 2
Move after 2sec.
It displays when it is preset output type only and select output operation mode of preset output.
MD

MD

It displays when it is preset output type only.


MD Set hysterisis of preset. The range is 01 ~ 99.
MD
Set delay time of display value monit oring function.
MD The setting r ange is 00 ~ 30sec.
MD
Select delay time of display cycle.
MD sec
MD
Set the address of communication output.
MD (It shows when it has RS485 communication output only) S etting r ange is from 01 ~ 99.
MD
Select Baud rate of RS485 communicat ion output.

MD bps
MD
Set key lock function and select from 4 kinds. oFF No key lock function
MD LoC1 P arameter 1 lock
MD LoC2 P arameter 1, 2 lock
LoC3 P arameter 0, 1, 2 lock

▣Factory default setting


Mode M T4Y/W-DV MT4Y/W-DA MT4Y/W-AV MT4Y/W-A A Mode MT4Y/W-DV M T4Y/W-DA MT4Y/W-A V MT4Y/W-AA

▣PARAMETER 0 group
RUN
MD Key to uch
Set preset High-limit value. ( : Enter to mode, move the digit, : Chane the sett ing value)
※It is displayed when set the preset only.
MD When set in [ ] mode if P A2, the parameter is not displayed
MD
Set preset Low-limit value. ( : Enter to mode, move the digit, : Chane t he s etting value)
※It is displayed when set the preset only.
MD When set in [ ] mode if P A2, the parameter is not displayed
MD

It shows High-limit monitor ing value while it is operat ing.


It will be reset by pressing key.
MD
MD MD

It shows Low-limit monitoring value while it is r unning.


It will be reset by pressing key.
MD
MD MD ※ When the display value against measuring input reaches a stable state aft er supplying initial
power, please initialize mode before using t his unit. (If do not r eset it, it can display
Low-limit value as " " cause of Peak value of Low-limit value is 0.)
※ If " " is set in [ ] mode of paramet er 2, [ ] and [ ] modes will not be displayed.

▣Factory default setting


M ode MT4Y/W-DV MT4Y/W-DA M T4Y/W-AV M T4Y/W-AA

E-21
Multi Panel Meter
▣Function
(A)
◎Prescale function [PA1 : / mode] ※The offset correction range of is within -99 to
Counter
+99 for D - 0 , D -1 digit regardless of decimal point.
This function is to display setting(-9 99 to 9 999) of
Display value for measuring input(500V) is decided
particular High/Low-lim it value in order to display
by offset adjustment of low value. In case display
High/Low-limit value of measuring input.
value is "501.0" display value will be 500.0 by adjusting (B)
If measuring inputs are a or b and particular values are Timer
the gradient of high display value if 0.998 of correcting
A or B, it will display a=A, b=B as below graph. value is set at by calculating 500.0/ 501.1(Target
B B display value/Current display value)
B Display Display (C)
Display
A
a ◎Display cycle delay function [PA 2 : mode] Temp.
A b controlle
It is difficult to read as display value follows the measuring
a b a b A
Input Input Input input value. Display when the measuring input value is
fluctuating. In this case it is able to make display value
a b
A A stable by delaying display cycle.Display cycle displaying (D)
Display A b Power
tim e can be changed in m ode of Parameter 2 controlle
B Display Display a
(Selectable 0.1s/0.2s/0.5s/1.0s/2.0s/4.0s). If select 4.0s,
a b B
Input B the display value is displayed every 4sec. averaging
Input Input
input value for 4sec. (E)
◎Correction function [PA 1: mode] ◎Monitoring function for Peak display value
Panel
meter
This function is to correct a gradient of prescale value [PA 0 : / mode]
and display value. It is to observe Max ./Min. value of display value by (F)
(Fig.1)Display value Y can be used as α,β times against current display value and then display the data in Tacho/
Speed/
X input value by correction function[ ]. mode and mode of parameter 0. Pulse
And also can be used as correction function of max. Set delay time(0 to 30sec.) in mode of parameter meter

display value( ). A djustment range is 0.100 to 5. 2 in order to prevent malfunction caused by initial over
000 and multiply current gradient. current or over voltage, when it monitor the peak value. (G)
Delay time is 0~30sec. and it will monitor the peak value Display
unit
αY Ex)Input:200mVDC, Display:3.000 after setting time. If press ◀ key at and mode
Display αtimes
for MT4W-DV of parameter 0, monitoring data will be initialized.
value
Y ①Select 0~1VDC for measuring
βtimes ◎Terminal ordering by output specification
βY input in Parameter 1. (H)
Preset output S ub output Sensor
②Standard specification in input: Output controlle
X 0 to 1VDC and 1.000 therefore NPN open PNP open
0 Input Output Relay collector collector RS485 Serial BCD 4-20mA
value it has to be 15.000( ) for terminal output output output output output output output
(Fig. 1) 1VDC(input) in order to display Terminal Type ◎ ◎
Display (I)
value 3.000 for 200mVDC(input). 20Pin HIROSE ◎ ◎ ◎ ◎ ◎ ◎ Proximit
15.000 But it is unable due to setting sensor
※P reset output and ret ransmission output are option according to
12.000 range is 9.999 st ructure of out put terminal.
③In this case, please check below
9.000
Display ◎Preset output mode [PA 2 : mode] (J)
6.000 value for chart. Please set as Photo
measuring Mode Output oper ation Operation
3.000 × =15.000 electri c
input OFF No output sensor
1.000
0.2 0.4 0.6 0.8 1V ON
If it is equal or smaller than Low
setting value, LO output will be ON.
Input value L.St ON H OFF
If it is bigger than Low setting value,
LO GO (K)
(Correct gradient) GO output will be ON. Pressur
If it is equal or bigger than High sensor
S etting Other ON
setting value, HI output will be ON.
① Disable 0.000 1.000 H.St OFF H ON
If it is equal or smaller than High
GO HI setting value, GO output will be ON.
② 7.500 0.000 2.000
If it is equal or smaller than Low (L)
③ 5.000 0.000 3.000 It will be the same setting value and equal or bigger Rotary
O FF ON OFF encoder
④ 3.750 0.000 4.000 display value. than High setting value, the output
LH.St will be ON. If it is bigger than Low
⑤ 3.000 0.000 5.000 ON H OFF OFF H O N
setting value and smaller than High
LO GO HI setting value, GO output will (M)
◎Correction function [PA 1: / mode] be ON. 5-Phase
stepping
This function is for correcting display value error of If it is equal or bigger than Low set motor &
ON and equal or bigger than High set Driver &
measuring input. value, output will be ON. If it is Controlle
HH.St smaller than Low setting value and
: ±99[Adjust deviation of Low value], OFF H ON OFF H ON
GO LO HI High setting value, GO output will
: 5.000 ~ 0.100[Correct gradient(%) of High value] be ON.
Ex)When the user desires measuring input specification This operation is the same as L.St.
ON But it doesn't operate at initial Low
is 0 to 500V and display value is 0 to 500.0, it is set value, it will operate at next
Ld.St ON H OFF
able to remove the offset of Low display value to Low set value. If this is higher than
LO GO Low set value, Go output wil be ON.
set -12(Offset correcting value) in (When Low
※"H" means hysteresis and able to set 1 to 99 at " " mode in
display value is "□□ 1.2" in 0V input) Parameter 2 among above comparison output chart.

E-22
MT4Y/MT4W Series
◎Retransmission function(Sub output) ▣Communication output
lRS4 85 communication output(32 channels)
◎System ordering
It is able to set address(01~99)
Vertical r esistance N
It is able to transmit by selecting modulation speed
RX TX
(Transmitted number of signal per 1sec.) of serial
Upper MT4W
transmission. (Selectable 1200, 2400, 4800, 9600bps)
TX RX
lLow-speed serial output
It outputs current display value as Low-frequency(50Hz)
RX TX RX TX
type. MT4W MT4W
lCurrent output(4-20mADC)
1 (N-1)
It outputs 4-20mADC against High/Low-limit scale.
(Resolution:8 ,000 division)
◎Communication control ordering
lBCD output 1. The communication control ordering of MT4 series
It outputs display value as BCD Code. is protocol(Not compatible with other system).
※Only one sub-output is selectable(More than one 2. After 4sec. being supplied the power in to upper
sub-output is not allowed.) system, then able to start communicating.
◎Time chart of serial output and BCD output 3. Initial communication will be started by upper
lBCD output(Negative logic) system. When Command signal come out from
t upper system then MT4 series will response.
t : 7.8ms


ta tw tb ta : 0.5ms If there is no response after 3times of the command
tw : 5ms signal from upper system, error will be occurred.
Digit signal tb : 2.3ms S A C T E C S A C T E C
T DM X T R T D M X T R
X R D T X C X R D T XC
Input Dat a Data Upper

A S A C T E C
30ms C T D M X T R
MT4W K X R D T X C
D3
A B C
D2

D1 ※A → Over min. 4sec, B → Within max. 300msec,


C → Over min. 20msec
D0
◎Communication Command and Block
A H L H L H
Format of Command and Response
B H L L H H 1 0
STX 10 10 R/W X/D ETX CRC

C L H H H H
Star t Addr ess Header Text END CRC
Code Code Code Code Code
D H H H H H
Calculation range of CRC Check S um

dot H H L H H ①Start Code


Disp lay It shows the first of Block
STX → [02H], in case of Response, ACK/NAK
lLow speed serial output(Negative logic) will be added.
*tw
t : 20ms ②Address Code

Latch
t *ta *tb
{ ta : 0. 05ms
tw : 5ms
tb : 4.95ms
This code is upper system can discern MT4
series and able to set within range of 00 to 99.
(BCD ASCII)
Clo ck Cn-1 Cn C1
③Header Code
It shows Command as 2 alphabets as below.
D ata D n-1 Dn D1
RX(Read request) → R[52H], X[58H]
Input 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2
RD(Read response) → R[52H], D[44H]
sequence
DP D C B A DP D C B A DP D C B A DP D C B A DP D WX(Write request) → W[57H], X[58H]
Clock (Reserve in upper version of MT4W)
H H L H H H H H L L L H H L H H H H H L WD(Write response) → W[57H], D[44H]
Data
*tw
*ta *tb ④Text
Latch
It indicates the detail contents of Command/
Display
Response. (See the command)
⑤END Code
※When clock pulse changed from High to Low, Data will be read. It indicates the end of Block. ETX → [03H]

E-23
Multi Panel Meter

⑥CRC i s Cyclic Redundancy C heck and called 3. In case of CRC error, only NAK[15H] is transmitted. (A)
Counter
polynominal code. (It means retransmission is requested )
CRC is for more reliable transmit/receive to check 4. When ACK/NAK has no response
the error between transmitter and reciever. ①When address is unmatched after STX response
(B)
There are CRC-8, CRC-16 and CRC-32, CRC- ②When receive buffer is overflowed Timer
8 has been adopted in MT4 series according to ③When borate or other communication setting
CCITT-8 Polynomial regulation. (See CRC) value is unmatched
Result value is HEX 1 Byte. 5. Process below when no response of ACK/NAK (C)
Temp.
lCRC-8 Table ①At first, check line controlle

0 1 2 3 4 5 6 7 8 9 A B C D E F ②Check communication condition(Setting value)


0 0x00 0x5E 0xBC 0xE2 0x61 0x3F 0xDD 0x83 0xC2 0x9C 0x7E 0x20 0xA3 0xFD 0x1F 0x41 ③Try to do communication operation around 3times
1 0x9D 0xC3 0x21 0x7F 0xFC 0xA2 0x40 0x1E 0x5 F 0x01 0xE3 0xBD 0x3E 0x6 0 0x82 0xDC
in case communication error by noise (D)
2 0x23 0x7D 0x9F 0xC1 0x42 0 x1C 0xFE 0xA0 0xE1 0xBF 0x5D 0 x03 0 x80 0xDE 0x3C 0x62 Power
④Change the speed of communication when commu controlle
3 0 xBE 0xE0 0x02 0x5C 0xDF 0x81 0x63 0x3 D 0x7C 0x22 0xC0 0x9E 0x1D 0x44 0xA1 0xFF

4 0x46 0x18 0xFA 0xA4 0x27 0x79 0x9B 0xC5 0x84 0xDA 0x38 0x66 0xE5 0xBB 0x59 0x0 7 -nication error is occurred frequently
5 0xDB 0x85 0x67 0x39 0xBA 0xE4 0x06 0x58 0x19 0x47 0xA5 0xFB 0x78 0x2 6 0xC4 0x9A
lWhen error has occurred (E)
6 0x65 0x3B 0xD9 0x87 0x04 0x5A 0xB8 0xE6 0xA7 0xF9 0x1B 0x45 0xC 6 0x9 8 0x7A 0x24

7 0xF8 0xA6 0x44 0x1A 0x99 0 xC7 0x25 0x7B 0x3A 0x64 0x86 0xD 8 0x5B 0x0 5 0xE7 0xB9
(Multi-meter operation error has occurred even Panel
meter
8 0x8C 0xD 2 0x30 0x6E 0xED 0xB3 0x5 1 0x0F 0x4E 0x10 0xF2 0xAC 0x2F 0x7 1 0x9 3 0xCD if normal response)
9 0x1 1 0x4F 0xAD 0 xF3 0x70 0x2 E 0xCC 0x92 0xD3 0xBD 0x6 F 0x31 0xB2 0xEC 0x0E 0x50 In case of normal response, data with ACK[06H] is
A 0 xAF 0xF1 0x13 0x4D 0xCE 0x90 0x72 0x2 C 0x6D 0x3 3 0 xD1 0xBF 0x0 C 0 x52 0 xB0 0xEE (F)
transmitted;(When present value of ch 0 is + 1.234) Tacho/
B 0x32 0x6C 0x8E 0xD0 0x53 0 x0D 0xEF 0xB1 0xF0 0xAE 0x4 C 0x12 0x9 1 0xCF 0x2D 0x73 Speed/
A S D E C Pulse
C 0xCA 0x94 0x76 0x28 0xAB 0xF5 0x17 0x49 0x08 0x5 6 0 xB4 0xEA 0x69 0x3 7 0xD5 0x8B
C T 0 1 Err D P 0 10 5 10 4 10 3 10 2 10 1 10 0 . T R meter
D 0x57 0x09 0xEB 0xB5 0x3 6 0x68 0x8 A 0xD 4 0x95 0xCB 0x29 0x77 0xF4 0xAA 0x48 0x16 K X No. P X C
E 0xE9 0xB7 0x55 0x0B 0x88 0xDB 0x34 0x6A 0x2B 0x75 0x97 0xC9 0x4A 0x1 4 0xF6 0xA8
A S E C
F 0x74 0x2 A 0xC8 0x96 0x1 5 0x4B 0xA9 0xF7 0xB6 0xE8 0x0A 0x54 0xD 7 0x89 0x6B 0x35 C T 0 1 1~9 D P 0 + 0 0 1 2 3 4 3 T R (G)
K X X C Display
unit
◎Kinds of Communication Command C
31H
06H 02H 30H 31H 44H 50H 30H 2BH 30H 30H 31H 32H 33H 34H 33H 03H R
lRead[RX] of measuring value : Address 01, ~39 C
Command RX
(H)
1.Command(Upper) ▣Caution for using Sensor
①Command controlle
1. It is not possible to modify Parameter(Baud rate,
STX 0 1 R X P 0 ETX CRC
Address etc)related to communication of MT4
Start Address Header End Check
code code code code sum series on line with upper systems such as PC, (I)
Proximit
Channel 0~7 PLC etc. (Error will occur) sensor
M T4W has Channel 0 only
P : Present Value 2. First make communication Parameter of MT4
M T4W has P value only series and upper system one. (J)
②Ex) : When address is 01, header code is RX, 3. It is not allow to set overlapping communication Photo
electri c
present value of ch(0) is P, CRC check number at the same communication line. sensor
sum is OAH ; (Error will occur)
STX 0 1 R X P 0 ETX CRC 4. Please use Twist pair wire for RS485 commu-
(K)
02H 30H 31H 52H 58H 50H 30H 03H CRC nication. Pressur
sensor
5. The total length of communication is 800m and
lResponse
over 32 equipment can be connected.
1. In case of normal response, data with ACK[06H] is
6. When connect communication cable between MT4
transmitted ;(When present value of ch 0 is +1.234) (L)

C
series and upper systems, the vertical resistance Rotary
A S D E encoder
C T 0 1 R D P 0 10 5 10 4 10 3 10 2 10 1 10 0 . T R (100 to 200Ω) must be installed at between both
K X P X C

A C
communication lines. (M)
S E
C T 0 1 R D P 0 + 0 0 1 2 3 4 3 T R 7. Please check Parameter related to communication 5-Phase
K X X C stepping
①Start bit : 1(Fixed) motor &
C Driver &
06H 02H 30H 31H 52H 44H 50H 30H 2BH 30H 30H 31H 32H 33H 34H 33H 03H R ②Stop bit : 1(Fixed) Controlle
C
③Parity bit : Non(Fixed)
2. When measurement value is -999 ④Data bit : 8(Fixed)
E C
A S
0 1 R D P 0 - 0 0 0 9 9 9 0 T R
⑤Baud rate : 2400, 4800, 9600(Setable)
C T
X
K X C ⑥Address : 00 ~ 99(Setable)
C
06H 02H 30H 31H 52H 44H 50H 30H 2DH 30H 30H 30H 39H 39H 39H 30H 03H R
C

E-24

Anda mungkin juga menyukai