Anda di halaman 1dari 3

Technical specification for online dynamic motor analyser

Scope: - supply of dynamic online motor analyser to monitor and assess conditions across a
motor/machine system that impact the health and performance of the motor. It evaluates the
quality of power fed to a motor, assesses motor performance indicators, and examines the amount
and condition of the load of the AC 3 phase induction motor.

Features: Kit should capable to measure mention below parameters:

 Power quality
 Machine performance
 Current
 Spectrum
 Torque
 Efficiency
• Time waveforms
• Analyses effective service factor, load, operation condition
• Variable-frequency drives performance
• Continuous monitoring
• Transient analysis
• Vibration
• Efficiency
• DC motor monitoring

Current: Problems such as over-loading, poor connections, misconnections, iron saturation and mis
wound motors are difficult to detect without the right equipment, the instrument should be capable
to evaluate current and current imbalances to assess the overall electrical condition of the
motor/machine system.

Power quality:-
The instrument should be capable to identify power quality problems that can stress a motor, such
as distortion, imbalances or improper levels. The instrument monitors power, voltage and current
levels/imbalances, and total as well as harmonic distortion. These can identify such problems as:
improper tap settings on supply transformers
poorly-distributed single-phase loads
excessive non-harmonic frequencies
missing or open power-factor correction capacitors
high-resistance connections
Machine performance

Spectrum:-

Hard-to-detect issues such as broken rotor bars or bearing faults can be detected with the
instrument’s spectrum analysis capabilities, including demodulated spectrum, harmonics and rotor
bar tests, which help to determine mechanical vs. electrical issues. These capabilities are enhanced
by zoom able, high resolution spectrum plots, and high sample rate. The user can set frequency
markers on a graph that are specific to a given machine system’s design
Time waveforms:-
Time waveforms are essential for swift identification of underlying causes of warning or caution level
parameters and transient conditions. They graphically represent voltage, current and torque vs. time

Torque:-
The instrument should have innovative torque analysis capabilities which can expose torque-related
problems. The kit should have torque- time and spectrum signatures are used to diagnose
mechanical problems, and to clearly identify transient conditions. Users can accurately identify such
issues as over-torque, over-load, cavitation, bearing problems, mechanical imbalances,
eccentricities, misaligned shafts and more.

Instrument software should be capable to display Torque Ripple


The Torque Ripple is a direct relation of what is happening on the load side of the shaft. The load is
what dictates more of less torque from the motor. Having the ability to record the incoming power,
the current and torque simultaneously is the only way to separate between mechanical, incoming
power and motor problems.

Instrument should be cable to display Current, Voltage and the Torque Spectra, this will allow the
operator to find problems earlier with the Torque Spectra than the Current Spectra.

Transient start up
Kit should be capable Accurately troubleshooting any motor system issues at start-up and diagnosing
timing issues involves discerning if a problem is with the power fed to the motor, the motor itself, or
the load. The kit should be capable up to displays 6000 samples per second for all three phases of
current and voltage, and torque. The user can zoom in, pan and move a cursor to read values from
specific points on the graphs. Common uses are setting relay points, viewing soft start stages,
identifying over-torquing with heavy loads, and identifying which phase tripped on start-up (V or I).

Technical specifications:

Input power 110 - 250V AC, 50/60 Hz. Integrated


power supply.

Maximum rated measurement/test 1000V AC, 500V DC (existing PTs and CTs
voltage are used for high voltage applications)

Current transformers (portable) 10A, 40A / 400A (switchable), 150A,


1000A, 3000A

Connections (Amphenol military twist Power entry module


type) Portable voltage connection (1)
Portable current connection (1)
EP port (1)
Weight Not more than 7Kg

Computer specifications 1 tb hard drive , i7 gen8 processor


8 GB memory , 4gb graphics card
Microsoft Windows 10 operating system
USB port

Industrial standards NEMA MG-1, IEEE 519, EN61000-2-2,


EN61000-2-7, VDE 839-2-2

Power supply Kit should have built-in battery operation.

Instrument should supplied with


Connection necessary CT and PT probes required for
testing also shall be supplied with
applicable device which is directly
connected to panel in order to capture the
results and eliminates the need of CT/PT
probe connection outside.

PQC :

1) Any technical deviation from technical specification will not be accepted and bidder is
liable to get reject on noncompliance of technical specifications. Purchaser can call bidders
for demonstration of equipment before price bid opening as a part of technical evaluation if
he finds some deviation in technical specifications. If the product offered by the successful
bidder fails to perform as per Technical Specification of tender, the firm shall be liable for
forfeiting of the Earnest Money and Performance Bank Guarantee and further deemed
suitable action as per provisions of the PO/ Contract/ Regulations etc. shall be initiated
against the firm.
2) The bidder shall provide the copy of purchase order of offered model supplied to any
Govt. Utilities in India.
3) The bidder shall provide at least one performance report/certificates of offered product
from any Govt. Utilities in India for at least 7 years.
4) The Manufacturer of offered products should have their own presence & base in India
having facilities for technical & after sales support, calibration set-up and service centre in
India from last 5 years at least. Documentary proof with company registration certificates
should be provided from manufacturer. PO copies in support of above shall be submitted.