Design Wind Force on RRU

Shape of Panel Flat
Length of panel 400 mm
Width of Panel 300 mm
Depth of Panel 220 mm
Antenna Mount Height Zh 33 m
Number of Panels 3
Azimuth Panel 1 0 °
Azimuth panel 2 120 °
Azimuth Panel 3 240 °
2.6.5.2 Velocity Pressure Coefficient Kz 1.01
Table 2‐5 Heigh Attenuation Factor f Not Applicable
2.6.6.4 Height Reductio Factor Kh Not Applicable
Table 2‐4 Terrain Constant Ke 0.9
Table 2‐5 Topographic Constant Kt Not Applicable
2.6.6.4 Topographic Factor Kzt 1.00
Table 2‐2 Wind direction probability factor Kd 0.95
Table 2‐3 Importance factor, I 1
2.6.9 Velocity Pressure qz 941.76 N/m2
Table 2‐8 Velocity Coefficient C 12.06
Table 2‐8 Force Coefficient for Flat Appurtenance Cf 1.20
2.6.9.2 Effective Projected area for Normal Face EPAN 0.14 m2
2.6.9.2 Effective Projected area for Side Face EPAT 0.11 m2
2.6.9.2 Shielding Factor for Appurtenances Ka 0.8
Design Wind force for 0° 0.31 kN
Design Wind force for 45° 0.31 kN
Design Wind force for 90° 0.31 kN
Design Wind force for 135° 0.31 kN
Design Wind force for 180° 0.31 kN
Design Wind force for 225° 0.31 kN
Design Wind force for 270° 0.31 kN
Design Wind force for 315° 0.31 kN