The equipment has reliable functional performance as its design, but you should
avoid man-made damages to it.
Please read this Manual carefully and keep it for later
reference.
Conversion if necessary.
Under following conditions, please cut off the power immediately and
contact with us.
User's
manual
Cautions
Any part of this manual can’t be copied or transmitted as any form Catalogue
on network without written form permission of our company. The brand
ownerships that are mentioned in the manual are belonged to every I. Introduction to the System ...................................................... 1
brand owner. The company has the right of changing products II.Main Feature ........................................................................ 1
performance and this manual at any time without informing clients. III.Technical Parameter............................................................ 2
We don’t take any responsibility for invalidation of products or 3.1. 2048Kbit/s interface electricity feature........................ 2
damages caused by any form modification of products or this manual. 3.2. 10Base-T Interface................................................... 3
3.3. Power Supply Condition.......................................... 3
Our company supplies one-year free repair service and takes 3.4.Working Environment................................................ 3
responsible for maintenance a lifetime long for legal users. 3.5.Size ............................................................................ 3
During the warranty period, we take responsibility for changing the IV. Appearance............................................................................ 3
products that can’t be used because of quality problem, and the company V. On-0ff Switch Setup............................................................... 5
has the ownership of the reclaimed products. 5.1. Foundational On-off Switch Setup .............................. 5
5.2.Time slot switch establishment .................................. 6
5.3.interface impedance establishment ............................ 9
VI.Interface Definition ........................................................ 10
6.1.75ΩE1 interface definition .................................... 10
6.2.Ether interface Definition ...................................... 10
6.3.120ΩE1 interface definition .................................. 11
VII.Plan Constructor............................................................ 11
VIII.Accessories .................................................................. 12
IX. Warranty instruction ......................................................... 13
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment
1 2
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment
3 4
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment
OFF
12345678 12345678 12345678 12345678 12345678 P.S.:
ON
SW1 SW2 SW3 SW4 SW5 1、 The equipment must be used as pair, you can setup the equipment as
This equipment establishment switch including function one main clock and one secondary clock when you use it.
establishment switch and time slot selection switch,SW1 is the 2、 If is selects time the network management method,Asks you to establish
function switch,SW2-SW5 is the time slot selection switch. the equipment SW1.8 establishment switch ON to control softly the
SW1 setup condition. But this time equipment all establishments receive the
SWITCH ON OFF explain software control the hardware switch to be invalid
SW1 1 standby application 3、 If the user uses the network management the way to carry on
2 According the following the management,Then in time slot choice,Cannot choose the
Model of clock
3 table transparent 2M speed. The maximum speed can designate 31
4 time slots,Namely 1984Kbit/s,Otherwise will not be able the
standby application
5 network management;
6 This end Working
ring normally 5.2.Time slot switch establishment
returns
OFF
7 The far Working 2048Kbit/s passes passes on ON
12345678 12345678 12345678 12345678 12345678
SW1 SW2 SW3 SW4 SW5
end ring normally when does not have this
returns function
5 6
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment
7 8
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment
SW7.1 SW7.2
Pin number Functional definition Sense
OFF 75Ω 120Ω
1 RX+(Receive data +) Input
ON 120Ω 75Ω
2 RX-(Receive data +) Input
3 TX+(Send data +) Output
The impedance establishes in the line board obvious position has 4;5;7;8 NC(air)
labeling
6 TX-(Send data -) Output
When equipment and computer network card direct connected
When the equipment establishes 75Ω,The E1 data connection is the
please use the overlapping segment; When equipment and
BNC attachment output; When the equipment establishes 120Ω, The
concentrator or ethernet switchboard connected please use
E1 data connection is the RJ-45 attachment output;
9 10
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment
1 2 3 4 5 6 7 8
DH2010A 机框
4 NC(air)
5 RX-(Receive data -) Input
6 TX-(Send data -) Output
7 GND(ground)
VIII.Accessories
8 NC(air)
One power cable
P.S.: 75Ω interfaces and 120Ω interfaces can’t be used Two BNC spindle heads
simultaneously, they should be controlled by on-off switch. One RJ-45 connector
An Instruction Manual
VII.Plan Constructor
11 12
DH2010 E1/10Base-T Conversion Equipment
13