Anda di halaman 1dari 9

Information for Your Safety

The equipment has reliable functional performance as its design, but you should
avoid man-made damages to it.
Please read this Manual carefully and keep it for later
reference.

DH2010 Don’t expose this equipment to rain or moisture.


Don’t put anything on the cable and prevent it form knotting up or unceasing.
Keep it out of reach.

E1/10Base-T Electrical connection and other equipment connectors should be


securely jointed, and please check them often.
Please keep the equipment clean and wipe it with a soft cotton cloth

Conversion if necessary.
Under following conditions, please cut off the power immediately and
contact with us.

Equipment 1. The equipment is wet;


2. The equipment is broken or the enclosure is cracked;
3. The equipment works abnormally or the properties change
completely;
4. The Equipment emits smoke or some unusual smell and noise.
Please don’t mend the equipment by yourself except there are
obvious instructions.

User's
manual
Cautions
Any part of this manual can’t be copied or transmitted as any form Catalogue
on network without written form permission of our company. The brand
ownerships that are mentioned in the manual are belonged to every I. Introduction to the System ...................................................... 1
brand owner. The company has the right of changing products II.Main Feature ........................................................................ 1
performance and this manual at any time without informing clients. III.Technical Parameter............................................................ 2
We don’t take any responsibility for invalidation of products or 3.1. 2048Kbit/s interface electricity feature........................ 2
damages caused by any form modification of products or this manual. 3.2. 10Base-T Interface................................................... 3
3.3. Power Supply Condition.......................................... 3
Our company supplies one-year free repair service and takes 3.4.Working Environment................................................ 3
responsible for maintenance a lifetime long for legal users. 3.5.Size ............................................................................ 3
During the warranty period, we take responsibility for changing the IV. Appearance............................................................................ 3
products that can’t be used because of quality problem, and the company V. On-0ff Switch Setup............................................................... 5
has the ownership of the reclaimed products. 5.1. Foundational On-off Switch Setup .............................. 5
5.2.Time slot switch establishment .................................. 6
5.3.interface impedance establishment ............................ 9
VI.Interface Definition ........................................................ 10
6.1.75ΩE1 interface definition .................................... 10
6.2.Ether interface Definition ...................................... 10
6.3.120ΩE1 interface definition .................................. 11
VII.Plan Constructor............................................................ 11
VIII.Accessories .................................................................. 12
IX. Warranty instruction ......................................................... 13
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment

z E1 interface with BNC connector as 75Ω, and RJ-45 connector as


I. Introduction to the System 120Ω, controlling by switch;
z Supplying one Ethernet interface, port model is 10/100M adaptation;
DH2010 E1/10Base-T Conversion Equipment is a high-tech and
z Ether port can connect with computer network card or Ethernet switchboard
qualified product that was invented by our company. It’s a kind of
and other equipment;
conversion equipment that exchanges all or part E1 time solt
z Supplying two types clocks to choose: main clock and secondary clock;
interface into Ethernet interface. The Ethernet interfaces can
z Having perfect functions of warning and conditional indication;
connect with computer network card or switching exchange, line
z Suiting different power resource environment -48VDC/220VAC;
concentrator and other equipments. Moreover an equipment also
z The system provides the function formidable network management function
provides the special-purpose network management software to provide
and the support program promotion;
the function formidable network management function and the support
program promotion. Ether interfaces as 10/100M adaptation mode, make
III.Technical Parameter
good use of network resources, optimizing network transmission,
cutting down the user’s cost. It’s ideal equipment for cheap
bridging link condition and it could be used as a local area network
3.1. 2048Kbit/s interface electricity
(LAN) stretcher.
This equipment supplies integrated facilities. Each machine
feature
frame has 15 slot position, which all can be used for plug-in
* Nominal speed velocity: 2048Kbit/s±50ppm;
equipment card,and the 15th slot position can be used for plug-in
* Code pattern of Interface : HDB3
network management card. Each machine’s slot position can be used
* Interface impedance: both 75Ω(unbalance) and 120Ω(balance);
for plug-in different cards ,too. such as DH2000K(E1/V.35)
、DH2010K
* Digital interface electricity feature: matching ITU—TG.703
(E1/10Base-T)and cards that can be plugged in optical transmitter and
* Jitter transmission feature: matching ITU—TG.823
receiver, for example DH30K、DH30VK、DH30EK. All these equipment can
* Input jitter capacity: matching ITU—TG.823
plug different cards synchronously.
* Output jitter: matching ITU—TG.823

II.Main Feature * 2048Kbit/s digital interface physical electric feature matching


ITU-TG.703
z Using massive integrated chipset, and the circuit is simple, * Type of interface: BNC——75Ω,RJ-45——120Ω;
stable and reliable;
z Supplying an E1 interface, resistance is 75Ω/120Ωas tunable type

1 2
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment

The front board of DH2010:


3.2. 10Base-T Interface
DH2010 E1/10Base-T
RL LL
* Nominal speed velocity: 10/100Mbit/s LINK ACT
12345678 12345678 12345678 12345678 12345678 E1
LOF
* Regulation rules of interface: matching IEEE-802.3u standard RA PWR
Functional switch Bundwidth Setup Switch
* Type of interface: RJ-45;
The front board of DH2010 E1/10Base-T Conversion Equipment
* Line transmission protocol: HDLC;
* The max speed of filtration and transmission is 15,000 frames
Meaning of DH 2010 E1/10Base-T indicator light (1)
per second
Name Color Meaning of indicator Normal
* Reinforced TINYGRAM packing model
light condition
* The 10,000MAC
POWER Green Equipment power source Bright
3.3. Power Supply Condition working indicator light
RA Green To carries the E1 frame Go out
Voltage: AC220V AC 180V~240V; out-of-step warning
DC-48V DC -36V~-72V; indicating lamp
Power Consumption: ≤5W ACT Green Ethernet interface data Flicker
indicator light
3.4.Working Environment E1 Green E1 connects the indicating Bright
lamp normally
* Working Temperature 0℃ ~ 50℃;
LOF Red E1 frame out-of-step Go out
* Storage Temperature: -40℃ ~ +70℃;
indicating lamp
* Relative Humidity: 5% ~ 95% without cold agglutinin
* Atmospheric Pressure: 86 ~ 106Kpa; LINK Green Ethernet interface Bright
connection indicator light
3.5.Size LL Yellow This end ring returns to Go out
the indicating lamp
* 200mm×145mm×35mm or 483mm×145mm×35mm RL Yellow Distant end ring returns to Go out
the indicating lamp
IV. Appearance

3 4
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment

The backboard of DH2010 8 Software hardtware


control control
IN OUT

Clock pattern establishment table::


LINK 75Ω 120Ω 75Ω
POWER SW1.2 SW1.3 Model of explain
The backboard of DH2010 E1/10Base-T Conversion Equipment clock
ON ON Inner
V. On-0ff Switch Setup clock
OFF ON secondary The work in receives the E1 clock
5.1. Foundational On-off Switch Setup clock

OFF
12345678 12345678 12345678 12345678 12345678 P.S.:
ON
SW1 SW2 SW3 SW4 SW5 1、 The equipment must be used as pair, you can setup the equipment as
This equipment establishment switch including function one main clock and one secondary clock when you use it.
establishment switch and time slot selection switch,SW1 is the 2、 If is selects time the network management method,Asks you to establish
function switch,SW2-SW5 is the time slot selection switch. the equipment SW1.8 establishment switch ON to control softly the
SW1 setup condition. But this time equipment all establishments receive the
SWITCH ON OFF explain software control the hardware switch to be invalid
SW1 1 standby application 3、 If the user uses the network management the way to carry on
2 According the following the management,Then in time slot choice,Cannot choose the
Model of clock
3 table transparent 2M speed. The maximum speed can designate 31
4 time slots,Namely 1984Kbit/s,Otherwise will not be able the
standby application
5 network management;
6 This end Working
ring normally 5.2.Time slot switch establishment
returns
OFF
7 The far Working 2048Kbit/s passes passes on ON
12345678 12345678 12345678 12345678 12345678
SW1 SW2 SW3 SW4 SW5
end ring normally when does not have this
returns function

5 6
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment

switch function ON OFF 6 time permission prohibit


1 time permission prohibit slot14
slot1 7 time permission prohibit
2 time permission prohibit slot15
slot2 8 time permission prohibit
3 time permission prohibit slot16
slot3 1 time permission prohibit
4 time permission prohibit slot17
slot4 2 time permission prohibit
SW2
5 time permission prohibit slot18
slot5 3 time permission prohibit
6 time permission prohibit slot19
slot6 4 time permission prohibit
7 time permission prohibit slot20
SW4
slot7 5 time permission prohibit
8 time permission prohibit slot21
slot8 6 time permission prohibit
1 time permission prohibit slot22
SW3
slot9 7 time permission prohibit
2 time permission prohibit slot23
slot10 8 time permission prohibit
3 time permission prohibit slot24
slot11 1 time permission prohibit
SW5
4 time permission prohibit slot25
slot12 2 time permission prohibit
5 time permission prohibit slot26
slot13 3 time permission prohibit
slot27

7 8
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment

4 time permission prohibit


slot28
VI.Interface Definition
5 time permission prohibit
slot29 6.1.75ΩE1 interface definition
6 time permission prohibit
slot30 Marked with IN means receiving
7 time permission prohibit signal;
slot31
8 2048Kbit/s Framing IN OUT Marked with OUT means sending

transparent way working signal;

5.3.interface impedance establishment 6.2.Ether interface Definition


12345678

The connection impedance default establishes as 75Ω


(non-balance),If establishes 120Ω (balance) the connection,Has the
switch in the equipment interior,Invites the reference next table
establishment

interface impedance establishment Ether interface Definition

SW7.1 SW7.2
Pin number Functional definition Sense
OFF 75Ω 120Ω
1 RX+(Receive data +) Input
ON 120Ω 75Ω
2 RX-(Receive data +) Input
3 TX+(Send data +) Output
The impedance establishes in the line board obvious position has 4;5;7;8 NC(air)
labeling
6 TX-(Send data -) Output
When equipment and computer network card direct connected
When the equipment establishes 75Ω,The E1 data connection is the
please use the overlapping segment; When equipment and
BNC attachment output; When the equipment establishes 120Ω, The
concentrator or ethernet switchboard connected please use
E1 data connection is the RJ-45 attachment output;

9 10
DH2010 E1/10Base-T Conversion Equipment DH2010 E1/10Base-T Conversion Equipment

goes nonstop to the segment. E1 传输环境:E1 Transmission Environment


中心局域网:Central LAN
6.3.120ΩE1 interface definition

1 2 3 4 5 6 7 8

DH2010A 机框

Pin number Functional definition Sense


1 RX+(Receive data +) Input
2 TX+(Send data +) Output
3 GND(ground) DH2010A DH2010A DH2010A

4 NC(air)
5 RX-(Receive data -) Input
6 TX-(Send data -) Output
7 GND(ground)
VIII.Accessories
8 NC(air)
One power cable
P.S.: 75Ω interfaces and 120Ω interfaces can’t be used Two BNC spindle heads
simultaneously, they should be controlled by on-off switch. One RJ-45 connector
An Instruction Manual

VII.Plan Constructor

11 12
DH2010 E1/10Base-T Conversion Equipment

IX. Warranty instruction


We supply one-year free repair service for consumers.

Instructions for free repair service:

1. Within one year of warranty period, we take free of charge repair


for damage under normal condition.
2. No free repair for damage caused by unauthorized repair.
3. Equipments that are out of warranty are not converted by the
free of charge repair and should be paid by the customer.

13