Jurnal 2 PDF
Jurnal 2 PDF
TURBOFAN CFM56-3
Afdhal Kurniawan Mainil (1)
(1)
Staf Pengajar Jurusan Teknik Mesin Universitas Bengkulu
ABSTRACT
This study focused on the performance analysis of a turbofan engine type used on
commercial aircraft with CFM56-3 type. The performance tests consisted of several stages
of testing are the the start up testing phase, the minimum idle, the idle approach, the
maximum continuous, the take off, and the acceleration. Each of test has the
characteristics, so the working, efficiency, and thrust at each condition are different. In
order to obtain comparisons between each condition, the Brayton cycle was used as a
reference, then the actual work and the ideal, the cycle thermal efficiency and engine thrust
from each test condition can be known. The highest thermal efficiency was achieved on the
actual take off condition with an efficiency of 37% while the ideal is 47%, for the actual
thrust of 2397.43873 lb while the ideal is 25091.96387 lb.
Keywords: engine turbofan CFM56-3, performance, thrust, efficiency
1. PENDAHULUAN 2. TINJAUAN PUSTAKA
Pesawat terbang merupakan alat transportasi yang 2.1 Turbin Gas
sering digunakan untuk menempuh jarak jauh dengan
Turbin gas seperti tampak pada “Gambar (1)”,
waktu yang relatif singkat. Dalam hal ini, faktor
merupakan suatu motor bakar yang terdiri dari tiga
keselamatan merupakan hal yang sangat penting
komponen utama yaitu kompresor, ruang bakar, dan
untuk diperhatikan. Baik sebelum melakukan
turbin. Salah satu penerapannya dapat digunakan
penerbangan, selama melakukan penerbangan, dan
untuk sistim propulsi yang berfungsi menghasilkan
setelah melakukan operasi penerbangan. Untuk itu
gaya dorong (thrust). Turbin gas yang digunakan
selain awak pesawat yang selalu dalam kondisi prima
untuk sistim propulsi salah satunya adalah tipe
juga perlu didukung oleh performa engine yang
turbofan [3,4,5].
sangat baik. Prestasi suatu engine diantaranya dapat
ditentukan dengan mengetahui kerja pada masing-
masing komponen, energi masuk, energi keluar,
efisiensi termal dan gaya dorong engine tersebut [1].
PT. Garuda Maintenance Facility (GMF) AeroAsia
merupakan salah satu instansi yang berkaitan erat
dengan perawatan maupun perbaikan pesawat
terbang yang kegiatannya meliputi pengecekan,
pembongkaran, pembersihan, perakitan, dan
pengetesan engine pesawat terbang. Proses
pengetesan engine dilakukan di suatu unit yang
disebut test cell [2] , yang mana dalam persiapannya
dilakukan secara manual dan pendataannya dengan
komputerisasi yang secara otomatis menghasilkan Gambar 1 Skema Engine Turbofan [3]
output berupa data pengujian.
2.2. Engine Turbofan CFM56-3
Dalam Penelitian ini Analisa difokuskan pada
performa suatu tipe engine turbofan yang digunakan Engine CFM56-3 merupakan mesin jet turbofan
pada pesawat komersial dengan tipe CFM56-3. dengan kapasitas bypass yang besar, dual rotor yang
pengujian yang dilakukan terdiri dari beberapa tahap digunakan dengan teknologi advance axial flow yang
pengujian. Tahap pengujian tersebut adalah start up, dirancang untuk digunakan pada pesawat terbang
minimum idle, approach idle, maximum continuous, jenis BOEING 737 dan variannya. Engine CFM56-3
take off, dan acceleration. Setiap pengujian memiliki yang ditunjukkan pada ”Gambar (2)” adalah produk
karakteristik masing-masing, sehinga, kerja, dari CFM International dimana merupakan
effisiensi, dan gaya dorong pada setiap kondisi perusahaan gabungan antara General Electric Aircraft
berbeda pula. Engine (GE) Amerika dengan perusahaan SNECMA
Perancis [2].
Analisa Kinerja Engine Turbofan CFM56-3 (Afdhal Kurniawan Mainil)
LE
TE
HPT LPT ZZ
ZZ
FAN HPC
OS
NO
NO
Siklus Brayton merupakan siklus daya
BO
ideal maupun aktual pada engine. Data-data tersebut yang dihasilkan sama. Fenomena tersebut
dalam grafik ditunjukkan pada “Gambar (7)”, diantaranya disebabkan oleh :
K erja
“Gambar (8)” dan vs K(9)”.
“Gambar ondis i
1. Tidak balancenya sudu-sudu sehingga
Wi Wa Qlos s es
menghasilkan tekanan dan temperatur yang
berbeda pada setiap titik sudu kompresor.
60
50 2. Adanya kebocoran sepanjang lintasan tiap-tiap
K erja (K j/K g )
40 tingkat kompresor.
30 3. Ketidakakuratan alat ukur yang digunakan.
20
10 Hal-hal di atas mempengaruhi besarnya panas yang
0 hilang selama proses kompresi pada kompresor
Minimum Idle Approach Idle Maximum Take Off sehingga dapat mempengaruhi besarnya kerja yang
C ontinuous
dibutuhkan untuk Qin vs K ondiskompresor.
menggerakkan i
K ondisi Qaktual Qideal
Q in (K j/K g )
800
Wi Wa Qlos s es
600
400
140 200
120
K erja (K j/K g )
0
100
Minimum Idle Approach Idle Maximum Take Off
80
60 C ontinuous
40
K ondisi
20
0 Gambar 10 Grafik Perbandingan energi masuk terhadap
Minimum Idle Approach Idle Maximum Take Off kondisi pengujian
C ontinuous
”Gambar (10)” menunjukkan adanya penurunan pada
K ondisi
kondisi approach idle. Besarnya energi yang
Gambar 8 Grafik Perbandingan kerja Booster terhadap dihasilkan sangat dipengaruhi oleh temperatur masuk
K erja vspengujian
kondisi K ondis i dan temperatur keluar dari ruang bakar. Pada kondisi
ini kenaikan temperatur pada ruang bakar lebih kecil
Wi Wa Qlos s es
dibandingkan kondisi minimum idle. Hal ini terjadi
karena pengaruh perbandingan massa aliran bahan
400
bakar dan udara yang masuk ke dalam ruang bakar.
K erja (K j/K g )
200 Nilai energi yang keluar dari sistim turbin gas ini
150 dipengaruhi oleh perbedaan temperatur masuk dan
100
50
temperatur keluar sistim turbin gas. Dilihat
0 dari”Gambar (14)”, terjadi perubahan nilai energi
Minimum Idle Approach Idle Maximum Take Off yang dikeluarkan ada sedikit penurunan pada
C ontinuous approach idle dari kondisi pengujian sebelumnya.
K ondisi Fenomena ini disebabkan sistim pendingin pada
turbin mulai bekerja dengan baik sehingga terjadi
Gambar 12 Grafik Perbandingan kerja LPT (Low Pressure penurunan temperatur pada gas yang keluar dari
Turbine) terhadap kondisi pengujian HPT, untuk lebih jelasnya dapat dilihat pada
”Gambar (15)”. Dengan demikian, sudah jelas bahwa
“Gambar (11)” dan “Gambar (12)” menunjukkan
dengan turunnya temperatur pada approach idle
kenaikan kerja alat ekspansi di setiap tahap kondisi
maka energi yang keluar
Perubahan akan menurun
Temperatur juga.
Vs Posisi
pengujian. Pada “Gambar (11)” terjadi penurunan
Qlosses, hal ini disebabkan karena perbedaan kerja Minimun Idle Approach Idle Maximum C ontinuous Take Off
ideal dan aktual semakin kecil. Fenomena ini terjadi
1800
karena adanya perbedaan perubahan temperatur pada 1600
setiap kondisi pengujian. Semakin tinggi perubahan 1400
T em p eratu r (K )
50
E fis ien s i T erm al
40
s iklu s (% )
30
20
10
0
Gambar 13 Pembagian kerja yang digunakan untuk Minimum Idle Approach Idle Maximum Take Off
C ontinuous
Qout vskompresor
memutar K ondis[3]i
Qaktual Qideal K ondisi
500
400 Semakin tinggi selisih antara energi masuk dan
300
200
energi keluar yang dihasilkan sistim maka nilai
100 efisiensi termal yang dihasilkan akan semakin tinggi.
0 Dilihat dari ”Gambar (16)” dapat disimpulkan bahwa
Minimum Idle Approach Idle Maximum Take Off terjadi kenaikan efisiensi pada setiap kondisi
C ontinuous
pengujian. Oleh karena itu salah satu cara untuk
K ondisi meningkatkan efisiensi termal dari sistim ini adalah
dengan cara meningkatkan energi yang masuk dan
Gambar 14 Grafik Perbandingan energi yang dikeluarkan menurunkan energi keluar sistim.
terhadap kondisi pengujian
81
Jurnal Teknik Mesin Gaya dorong vs K ondisi Vol. 8, No. 2, Desember 2011 ISSN 1829-8958
5.1. Kesimpulan
Dari pengujian yang telah dilakukan dapat diambil
kesimpulan:
1. Engine Turbofan CFM56-3 digunakan utuk
dapat menghasilkan thrust (gaya dorong) pada
pesawat
2. Dari hasil pengujian dan perhitungan yang
diperoleh, penulis mendapatkan selisih efisiensi
termal sebesar 9.59 % pada kondisi take off
3. Penurunan efisiensi termal pada engine CFM56-
3 antara lain disebabkan :
Pengaruh perubahan dimensi akibat material
yang bergesekan
Pengaruh kondisi lingkungan sekitar
5.2. Saran
Dari hasil pengujian dan analisis yang telah
dilakukan, adapun saran-saran yang dapat diberikan
adalah:
1. Dengan selisih efisiensi termal sebesar 9.59%,
artinya efisiensi masih dapat ditingkatkan
dengan semaksimal mungkin mengembalikan
dimensi komponen pada kondisi seharusnya
82