Anda di halaman 1dari 3

AXIAL CAPACITY OF BORED PILE  40 cm

TYPE END BEARING BASE ON SPT DATA INVESTIGATION

1. Bored Pile Bearing Capacity  40 cm ( Single Pile ) L =14 m :

From SPT Test:

Pile Diameter : Φ c  0.4m

1 2 2
Area Of End Pile Ac   π Φ c  125663.70614 mm
: 4

Pile Kllc  π Φ c  1.25664 m


Circcumference :
Pile Lenght : Lp  14m

to calculate end bearing pile predicted by SPT average of Value at the depht range 10 D above from end of
pile and 4D below the pile :

Above End Pile : b a  10 Φ c  4 m

Below End Pile : b b  4  Φ c  1.6 m

N Average for the End Bearing :capacity :

8  30  6  59
N60av   25.75
4

N Average for frictioh :

20  26  22  9  7  6  8  59
N60avf   19.625
8

END BEARING CAPACITY:

End bearing Capacity of Pile by Shio dan Fukui :

Lp
Qp1  0.3 N60av  MPa  Ac if 5  970.75213  kN
Φc

 Lp 
 0.1  0.04 Φ   N60av  MPa  Ac otherwise
 c

End Bearing Capacity of Pile by Briaud :

Qp2  19.7 100 kPa   N60av 


0.36
 Ac  797.17908  kN

End Bearing Capacity of Pile by Meyerhoff :

Lp Lp
Qp3  0.04  N60av  MPa  Ac if 0.04  0.4  1294.33617 kN
Φc Φc
0.4 N60av  MPa  Ac otherwise

Bored Pile Capacity - 1


End Bearing Capacity of pile by Martin :

Qp4  0.4 N60av  MPa  Ac  1294.33617 kN

FRICTION CAPACITY :

Friction Capcity of Pile by Shio dan Fukui :

Koef A : Ash  0 Koef B : Bsh  5

fav1   Ash  Bsh N60avf   kPa  98.125 kPa

Qs1  fav1 Lp Kllc  1726.30516 kN

Friction Capcity of Pile by Meyerhoff :

fav3  0.02 100 kPa  N60avf  39.25  kPa

Qs3  fav3 Lp Kllc  690.52207  kN

Friction Capcity of Pile by Briaud :

fav2  0.224  100 kPa   N60avf 


0.29
 53.10835 kPa

Qs2  fav2 Lp Kllc  934.33092  kN

Friction Capcity of Pile by Decourt :

Koef A : Ash2  10 Koef B : Bsh2  3.3

fav4  170kPa if  Ash2  Bsh2 N60avf   kPa  170  kPa  74.7625  kPa

Ash2  Bsh2 N60avf  kPa otherwise

Qs4  fav4 Lp Kllc  1315.2906  kN

TOTALALLOWABLE BEARING CAPACITY FOR 1 PILE:

Qp1 Qs1
Formulated by Shio Pu1c    733.56188  kN
Fukui : 2.5 5

Qp2 Qs2
Formulated by Briaud : Pu2c    505.73782  kN
2.5 5

Qp3 Qs3
Formulated by Pu3c    655.83888  kN
Meyerhoff: 2.5 5

Qp4 Qs4
Formulated by Martin and Pu4c    780.79259  kN
Decourt 2.5 5

Bored Pile Capacity - 2


Pu1c  Pu2c  Pu3c  Pu4c
Average Value : Pavg   668.98279  kN (66.8
4 ton)

Mid Value : Pu3c  655.83888  kN (65.5 ton)

ALLOWABLE PULL OUT CAPACITY OF 1 PILE :

Qs1
Formulated by Shio Pu1t   345.26103  kN
Fukui : 5

Qs2
Formulated by Briaud : Pu2t   186.86618  kN
5
Qs3
Formulated by Meyerhoff: Pu3t   138.10441  kN
5
Qs4
Formulated by Martin dan Pu4t   263.05812  kN
Decourt 5

Bored Pile Capacity - 3