1 2 2
Area Of End Pile Ac π Φ c 125663.70614 mm
: 4
to calculate end bearing pile predicted by SPT average of Value at the depht range 10 D above from end of
pile and 4D below the pile :
8 30 6 59
N60av 25.75
4
20 26 22 9 7 6 8 59
N60avf 19.625
8
Lp
Qp1 0.3 N60av MPa Ac if 5 970.75213 kN
Φc
Lp
0.1 0.04 Φ N60av MPa Ac otherwise
c
Lp Lp
Qp3 0.04 N60av MPa Ac if 0.04 0.4 1294.33617 kN
Φc Φc
0.4 N60av MPa Ac otherwise
FRICTION CAPACITY :
fav4 170kPa if Ash2 Bsh2 N60avf kPa 170 kPa 74.7625 kPa
Qp1 Qs1
Formulated by Shio Pu1c 733.56188 kN
Fukui : 2.5 5
Qp2 Qs2
Formulated by Briaud : Pu2c 505.73782 kN
2.5 5
Qp3 Qs3
Formulated by Pu3c 655.83888 kN
Meyerhoff: 2.5 5
Qp4 Qs4
Formulated by Martin and Pu4c 780.79259 kN
Decourt 2.5 5
Qs1
Formulated by Shio Pu1t 345.26103 kN
Fukui : 5
Qs2
Formulated by Briaud : Pu2t 186.86618 kN
5
Qs3
Formulated by Meyerhoff: Pu3t 138.10441 kN
5
Qs4
Formulated by Martin dan Pu4t 263.05812 kN
Decourt 5