Anda di halaman 1dari 8

See discussions, stats, and author profiles for this publication at: https://www.researchgate.

net/publication/235349330

CFD modeling of fouling in crude oil pre-heaters

Article  in  Energy Conversion and Management · December 2012


DOI: 10.1016/j.enconman.2012.05.003

CITATIONS READS
12 820

5 authors, including:

Mahmoud Bayat Javad Aminian


Research Institute of Petroleum Industry (RIPI) Shahid Beheshti University
9 PUBLICATIONS   92 CITATIONS    13 PUBLICATIONS   185 CITATIONS   

SEE PROFILE SEE PROFILE

Mansour Bazmi Shahrokh Shahhosseini


Research Institute of Petroleum Industry (RIPI) Iran University of Science and Technology
37 PUBLICATIONS   122 CITATIONS    119 PUBLICATIONS   780 CITATIONS   

SEE PROFILE SEE PROFILE

Some of the authors of this publication are also working on these related projects:

nanocatalyst View project

Experimental investigation of flameless combustion in a lab-scale utility boiler View project

All content following this page was uploaded by Khashayar Sharifi on 28 October 2017.

The user has requested enhancement of the downloaded file.


Energy Conversion and Management 64 (2012) 344–350

Contents lists available at SciVerse ScienceDirect

Energy Conversion and Management


journal homepage: www.elsevier.com/locate/enconman

CFD modeling of fouling in crude oil pre-heaters


Mahmoud Bayat a,⇑, Javad Aminian b, Mansour Bazmi a, Shahrokh Shahhosseini b, Khashayar Sharifi a
a
Research Institute of Petroleum Industry (RIPI), West Blvd. Azadi Sport Complex, P.O. Box 14665-1998, Tehran, Iran
b
Department of Chemical Engineering, Iran University of Science and Technology (IUST), P.O. Box 16765-163, Narmak, Tehran, Iran

a r t i c l e i n f o a b s t r a c t

Article history: In this study, a conceptual procedure based on the computational fluid dynamic (CFD) technique has been
Received 13 February 2010 developed to predict fouling rate in an industrial crude oil pre-heater. According to the developed CFD
Received in revised form 3 May 2012 concept crude oil was assumed to be composed of three pseudo-components comprising of petroleum,
Accepted 3 May 2012
asphaltene and salt. The binary diffusion coefficients were appropriately categorized into five different
groups. The species transport model was applied to simulate the mixing and transport of chemical spe-
cies. The possibility of adherence of reaction products to the wall was taken into account by applying a
Keywords:
high viscosity for the products in competition with the shear stress on the wall. Results showed a reason-
CFD
Modeling
able agreement between the model predictions and the plant data. The CFD model could be applied to
Crude oil new operating conditions to investigate the details of the crude oil fouling in the industrial pre-heaters.
Fouling Ó 2012 Elsevier Ltd. All rights reserved.
Asphaltene
Pre-heater

1. Introduction obtained more accurate results for an Alaskan crude oil. Yeap
et al. [4] have performed an extensive review on evaluating several
Crude oil fouling is a very complex phenomenon that occurs threshold fouling models applying various laboratory and plant
due to the simultaneous activities of several chemical and physical data sets. These models produce reasonable results for laboratory
mechanisms. Some of these mechanisms occurring in pre-heat experiments, whereas they give rough predictions when they have
exchangers of crude distillation units are deposition of waxes, salts applied to the industrial situations [4].
and corrosion products, chemical reaction fouling, sedimentation Vahdat Azad et al. [5] have proposed a novel graphical method
and bio-fouling. The cost of fouling in refineries of industrialized for increasing period of desirable heat transfer operation of heat
courtiers has been estimated to around $1.3 billion per year [1]. exchanger networks (HENs) without requiring cleaning process.
It arises from additional fuel required for the furnace, production In this method the time schedules and places of replacing high
loss during undesirable shutdowns, off-line and on-line cleaning fouling rate streams with those of low fouling rate are determined;
devices and also environmental penalties. The role of asphaltene thereby more opportunity of fouling formation is given to the HEN.
and salt deposition in crude oil fouling is ambiguous. Panchal [1] With a systematic experimental study, Herz et al. [6] demonstrated
were the first to introduce ‘‘threshold fouling’’ concept. The con- that the degree of surface roughness has a strong impact on the
cept provides a semi-empirical basis for interpretation of fouling deposition of calcium sulfate in a stainless steel tube. They showed
data in terms of deposition and suppression mechanisms. Thresh- that the fouling layer on a rough surface has a stronger adhesion
old condition is in fact the boundary between fouling and no-foul- and shorter induction period than those on a smooth surface.
ing zones. A number of threshold fouling models have been Recently, the application of numerical methods such as black-
developed based on the Ebert and Panchal model in order to ex- box modeling and optimization techniques to investigate crude
tend the prediction accuracy for various types of crude oil [2–4]. oil fouling phenomenon has obtained much attention due to the
Panchal et al. [2] have added the Prandtl number to the first ver- tremendous evolution in digital computing [7–11]. Aminian and
sion of threshold fouling model and extended its applicability to Shahhosseini evaluated the application of artificial neural network
crude oils with Prandtl number between 2.5 and 8.2. Polley et al. (ANN) to predict the complex behavior of fouling phenomenon for
[3] proposed the use of tube wall temperature instead of film tem- several types of laboratory and industrial crude oil heat exchangers
perature in the deposition term and also employed Reynolds num- [7,8]. Their proposed formulations based on the ANN approach
ber instead of wall shear stress in the suppression term and indicated better predictions in comparison with three different
threshold fouling models. Radhakrishnan et al. have also employed
⇑ Corresponding author. Tel.: +98 21 48259767; fax: +98 21 48259738. the ANN approach to predict fouling in pre-heat exchangers of
E-mail address: bayatm@ripi.ir (M. Bayat).
CDUs and successfully proposed a preventive maintenance

0196-8904/$ - see front matter Ó 2012 Elsevier Ltd. All rights reserved.
http://dx.doi.org/10.1016/j.enconman.2012.05.003
M. Bayat et al. / Energy Conversion and Management 64 (2012) 344–350 345

Nomenclature

Ao overall heat transfer area, m2 St Stanton number


Cp specific heat capacity, J kg1 K1 
u velocity vector, m s1
Dj mass diffusion coefficient of species j, m2 s1 UC clean overall HTC, W m2 K1
Ft temperature correction factor UD dirty overall HTC, W m2 K1
hi tube-side HTC, W m2 K1 Yj mass fraction of species j
Gk production rate of k in Eq. (7) Yk destruction rate of k in Eq. (7)
Gx production rate of x in Eq. (8) Yx destruction rate of x in Eq. (8)
hideal ideal tube-side HTC, W m2 K1
hio tube-side HTC based on tube outside diameter, W m2 - Abbreviations
K1 ESDU Engineering Sciences Data Unit
ho shell-side HTC, W m2 K1 SST Shear Stress Transport
ID tube inside diameter, m HTC Heat Transfer Coefficient
JC baffle cut correction factor
JL baffle leakage correction factor Subscripts
JB bundle bypass correction factor b bulk
JR laminar flow correction factor w wall
JS unequal baffle spacing correction factor
Jl wall viscosity correction factor Greeks
k production rate of turbulent kinetic energy q density, kg m3
m_ crude flow rate, kg s1 e dissipation rate of turbulent kinetic energy in k–e equa-
Nu Nusselt number tion
OD tube outside diameter, m x dissipation rate of turbulent kinetic energy in k–x equa-
p pressure, kPa tion
Q total heat load, W l dynamic molecular viscosity, kg m1 s1
rj intrinsic reaction rate of species j lt turbulent dynamic viscosity, kg m1 s1
R universal gas constant, J kmol1 K1 r turbulent Prandtl number
Rf fouling resistance, m2 K kW1
Re Reynolds number

scheduling tool using plant operating data [9]. A similar plan heat exchangers. The focus of this work is to include lumped-reac-
was pursued by Sanaye and Niroomand [10] and Rodriguez and tions for asphaltene and salt components through the species
Smith [11] in the heat exchanger networks (HENs) of petrochemi- transport model and use of appropriate molecular diffusion coeffi-
cal and refinery plants, respectively. These researchers have cients to predict fouling behavior in crude pre-heaters using CFD
developed, separately, similar numerical methods based on the technique. This study is established, mainly, based on an innova-
effectiveness-NTU approach to model the HENs and determine tive conceptual idea to predict the probability of reaction product
the amount of fouling deposited to estimate the overall heat trans- adhering to the tube wall and subsequent thickening of the fouling
fer and pressure drop versus time. By defining two similar objec- layer.
tive functions based on the total operating cost they have
predicted an optimal cleaning schedule for the HENs in each plant 2. Problem description
with noticeable economical savings [10,11]. In the above men-
tioned studies the details of fluid flow, temperature gradients An industrial shell-and-tube heat exchanger comprising of 618
and component concentrations on the rate of fouling were ruled tubes located in a one-pass shell with 24 baffles was modeled
out due to black-box or empirical approaches they employed. using the CFD technique based on a single tube model. The exchan-
Investigation of fouling phenomenon using white-box ap- ger is located in the pre-heat train of crude distillation unit (CDU)
proaches such as the computational fluid dynamic (CFD) is limited in Tehran oil refinery and heats up the crude oil coming from stor-
to a little number of studies. Brahim et al. [12] have simulated crys- age tanks using a high temperature fraction, iso-feed, flowing
tallization of CaSO4 on a flat plate using the commercial CFD code, through the shell-side. At the pre-heater inlet, crude oil and iso-
FLUENT. Walker and Sheikholeslami [13] have also investigated feed temperatures were varied between 186–220 °C and 272–
the effects of velocity and residence time on the isothermal and 298 °C, respectively. Along the exchanger, temperature of crude
non-isothermal flow domain, where calcium sulfate precipitation oil increased to the range of 224–256 °C while the iso-feed temper-
occurs. Zhang and Li [14] studied particle deposition of air in a ature decreased to about 226–259 °C. The crude volume flow rate
3D turbulent duct flow under different air speeds, applying RANS was also in the range of 641 and 854 m3 h1 yielding the tube Rey-
equations and Lagrangian particle tracing approach. In another nolds numbers in the range of 2e5–2.9e5.
study Zhang et al. [15] have investigated the effects of relaxation
time, particle size, air speed, turbulent flow development profiles 3. Numerical modeling
and surface orientations on the predicted deposition rates of parti-
cles. They have reported that particle deposition rate in the devel- Crude oil was assumed to be composed of three pseudo-compo-
oping turbulent flow section is higher than that in the fully nents; petroleum, asphaltene and salt. In general, thermo-physical
developed turbulent flow section. It has been shown that air veloc- properties of different crude oils vary widely. In addition, their
ity and particle size are the main factors influencing particle depo- temperature dependencies and reactivity, strongly determined by
sition rate in ventilation duct flows. their composition, can differ noticeably. The correlations for petro-
The previous studies suffer the lack of a systematic strategy for leum, presented in Table 1, have been obtained based on the labo-
CFD modeling of crude oil fouling in the industrial shell-and-tube ratory data available in the Tehran oil refinery.
346 M. Bayat et al. / Energy Conversion and Management 64 (2012) 344–350

Table 1
Thermo-physical properties of petroleum and other pseudo-components.

Density (kg m3) Viscosity (kg m1 s1) Thermal conductivity (W m1 K1) Heat capacity (J kg1 K1)
*
Petroleum 834.4  0.276Tb c  exp (d/33.28) 0.145  0.0001Tb 1671 + 4.4563Tb
Asphaltene 850 0.006 0.123 1500
Coke 900 150,000 1.500 1500
Saltb 850 0.006 0.123 1500
Saltw 900 180,000 1.500 1500
*
c ¼ 2:2085e  7  T 2b  1:3e  4  T b þ 1:9271e  2, d = 1.51Tb + 568.84.

 
Density, thermal conductivity and heat capacity of the other @ @ @p @ @u
ðqu
 Þ þ ðqu u
Þ ¼  þ ð l þ lt Þ þ qg ð2Þ
components have a minor role in crude oil fouling behavior. There- @t @ x @ x @ x @ x
fore, they were considered as typical values for fouling precursors
Using Fick’s law for diffusion, the species transport equation for
and reaction products. However, as a part of the developed CFD
species j is given as:
concept, the viscosity values of asphaltene, coke and salts were as-
 
sumed to be varied in a wide range. The assumption plays a major @ @ @ @Y j
role in the development of the fouling layer on the tube wall. The ðqY j Þ þ ðqY j u
Þ ¼ qDj  rj ð3Þ
@t @ x @ x @ x
possibility of adhering of fouled species (coke and saltw) to the wall
is determined based on the competition between their apparent where Dj is the mass diffusion coefficient and rj is the net reaction
high viscosities and the shear stress on the wall. rate of species j computed as follows:

X
Nr

3.1. Calculation domain and grid rj ¼ M w;j r j;k ð4Þ


k¼1

A 2D computational domain was adopted to reduce the CPU As shown in Eq. (4), rj represents the sum of the Arrhenius reac-
time associated with numerical simulation. The symmetric flow tion rates over the Nr reactions that the species j participate in. Mw,j
domain together with the boundary conditions is shown in Fig. 1. is the molecular weight of species j and rj,k is the Arrhenius rate of
The tube length and diameter were considered 500 and 25 mm, production/consumption of species j in reaction k. It will be dis-
respectively. In other words, the fouling behavior in the whole cussed later that reactions will occur at the tube wall surface
industrial shell and tube heat exchanger was mimicked using a sin- resulting in the surface deposition of product species.
gle 0.5 m tube long. The main drawback of this geometry is that it The energy conservation equation is:
could not be used to predict pressure profile along the exchanger  !
due to its shorter length compared to the industrial geometries. @ @ @p @ @T X @Y j
ðqEÞ þ ðqEuÞ ¼  þ keff  hj Dj þ Sh
However, prediction of pressure profile is not the aim of this study. @t @ x @ x @ x @ x j
@ x
The geometry was discretized applying 62,500 quadrilateral
ð5Þ
cells. The choice of very fine mesh grid in the whole radial direction
was aimed at considering the ability to predict very thick fouling where the two terms of the second part on the right-hand side of Eq.
layers occurring in the very long industrial operation periods. (5) represent energy transfer due to conduction and species diffu-
sion, respectively. Sh is also the heat of chemical reaction computed
3.2. Governing equations as follows:

X h0j
The partial differential equations governing the turbulent flow Sh ¼ rj ð6Þ
in the tube-side could be written in a Cartesian coordinate system j
Mw;j
as follows. 0
The conservation equation of mass is: where hj is the enthalpy formation of species j and rj is the net rate
of production of species j shown in Eq. (4).
@ q @ qu  The turbulent viscosity term (lt) was computed based on the
þ ¼0 ð1Þ SST version of k–x model [16]. The SST model employs the k–e
@t @ x
model [17] for the regions far away from the walls and the stan-
The conservation equation of momentum is: dard k–x model [18] near the wall. The turbulent kinetic energy

y axis
velocity pressure
x outlet
inlet
wall

Fig. 1. Flow domain, grid and boundary conditions.


M. Bayat et al. / Energy Conversion and Management 64 (2012) 344–350 347

k and turbulent frequency x are computed by the following ious molecular diffusion coefficients and thermo-physical proper-
relations: ties for different components in different situations. The
asphaltene diffusion coefficient has been reported to be in the
  
@ @ @ lt @k range of 1e10–1e11 m2 s1 [20,21]. This value generally has
ðqkÞ þ ðqu  kÞ ¼ Gk  Y k þ lþ ð7Þ been measured via laboratory experiments for diffusion of asphal-
@t @ x @ x rk @ x
tene in a resident toluene solution at the ambient conditions. How-
   ever, the high temperature, low viscosity flow of petroleum in pre-
@ @ @ lt @ x
ðqxÞ þ ðqu  xÞ ¼ Gx  Y x þ lþ ð8Þ heater tubes causes asphaltene to diffuse easier into the petro-
@t @ x @ x rx @ x
leum. Therefore, in this study the asphaltene diffusion coefficient
through the petroleum was set to 1e7 m2 s1. In addition to
where Gk and Gx are production terms of k and x and Yk and Yx
asphaltene–petroleum molecular diffusion coefficient, various
represent the destruction rates. rk and rx are also the turbulent
molecular diffusion coefficients were set for other pairs of the spe-
Prandtl numbers for k and x, respectively. The expression for turbu-
cies, which were categorized based on the following groups.
lent viscosity is then computed as:
2
k  First group: molecular diffusion of bulk species (such as asphal-
lt ¼ qa ð9Þ tene and saltb) through petroleum. As mentioned before the
x
value in this category was found to be 1e7 m2 s1.
in which, the coefficient a⁄ damps the turbulent viscosity causing a  Second group: molecular diffusion of bulk species through the
low-Reynolds-number correction. Detailed evaluations of these fouled layer. As fouling progresses, fouled species layers may
parameters are explained in the original Ref. [16]. stick to the tube wall based on the competition between their
high apparent viscosities and the shear stress on the wall. The
3.3. Boundary conditions fouled layer hinders the bulk species to reach the wall and react
on it. Thus, relatively high molecular diffusions (in the order of
As mentioned in Section 3.1, the main boundary conditions are 1e1 m2 s1) were chosen for this category to ensure that the
shown in Fig. 1. A uniform velocity, temperature and mixture com- bulk species could pass through the fouled layer and react on
position profiles were imposed at the tube inlet. The possibility of the wall.
the reverse flow at the outlet boundary, during the solution process  Third group: molecular diffusion of the fouled species through
was taken into account. A zero flux of all quantities was also as- fouled layer. The value of the molecular diffusion for this group
sumed across the tube wall. A fixed convection heat flux, related was chosen to be sufficiently high; 1e+0 m2 s1, to ensure that
to the average temperature and HTC of the shell-side fluid, was ap- the new fouled species could evacuate the wall surface rapidly
plied as boundary condition for the non-isothermal tube wall. A set and the new reactants (bulk species) can reach the wall and
of surface chemical reactions were also considered on the wall to react on it. Another reason to consider the high values for this
account for the production of species j in Eq. (3). category is that the new fouled species are supposed to have
the opportunity to return back to the top of the fouled layer
3.4. Development of numerical model and subsequently cause to thicken the fouled layer.
 Fourth group: molecular diffusion coefficients of fouled species
The unsteady state Reynolds averaged Navier–Stokes (RANS) through the petroleum. Molecular diffusion value in this cate-
equations were solved, in a finite volume scheme, for an incom- gory is very important since it represents the possibility of sep-
pressible turbulent flow applying the SST version of the k–x mod- aration of stuck fouled layer from the wall arising from the
el. As discussed in the previous section, this model appears to be competition between the adhesion forces (high apparent vis-
appropriate for investigation of fouling phenomenon. The pres- cosities) and the wall shear stress. It was found that the value
sure–velocity coupling was handled by the SIMPLE algorithm and should be very low. Considering very low diffusion coefficients
the convection terms were discretized using the second order up- for this group, it is very unlikely if new fouled species can sep-
wind scheme [19]. The appropriate under relaxation factors were arate from the fouled layer and float towards the petroleum
imposed to avoid instability in the solution. Arrhenius rate equa- flow. The choice of molecular diffusion values in this group,
tion was used to determine the rate of species formation on the together with the third group, will result in an increase in the
tube surface. Another major part of the developed CFD model is thickness of the fouled layer.
the contribution of chemical reactions, which lead to fouling for-  Fifth group: molecular diffusion of the bulk species through the
mation on the tube surface. The chemical reactions have consid- bulk species. This group has no significant effect on the fouling
ered based on two lumped surface reactions as follows: phenomenon and a moderate value of 1e3 m2 s1 was
considered.
2 asphaltene ! coke
ð10Þ
2 saltb ! saltw According to the CFD fouling concept mentioned above, follow-
The corresponding reaction rates shown in Eq. (11) are obtained ing three phenomena, schematically depicted in Fig. 2a, will result
by comparing the model predictions and experimental data: in formation of the first layer of fouling in the induction period:

1. Diffusion of bulk species (such as asphaltene and saltb) through


 r asph: ¼ 8  1020 e2e8=RT ½asph:0:5
ð11Þ petroleum (first group in the diffusion category).
 r saltb ¼ 1:2  1021 e2e8=RT ½saltb 0:5 2. Reactions of bulk species on the tube surface based on Eq. (9).
3. Adhesion of the reaction products to the tube wall by adjusting
The above pre-exponential factors and activation energies were very high apparent viscosities for them.
also set based on the corresponding molecular diffusions and may
differ if other sets of molecular diffusions are applied. On the other hand, the continuation of fouling formation and
The species molecular diffusion from the turbulent bulk to the thickening of the fouled layer in the developing period, schemati-
laminar sub-layer and their deposition on the wall was considered cally depicted in Fig. 2b, has been accounted for based on the fol-
applying a new strategy. This strategy assumes that there are var- lowing procedure:
348 M. Bayat et al. / Energy Conversion and Management 64 (2012) 344–350

2
(a)

Fouling resistance (m2 K kW-1)


1.5

0.5

(b)
0
0 500 1000 1500 2000
Time (hr)

Fig. 4. Plant fouling data related to a pre-heater in Tehran oil refinery.

4. Results and discussion

Fig. 2. Conceptual procedure of fouling formation in the (a) induction and (b) Plant data, collected from an industrial shell-and-tube heat ex-
developing periods.
changer, located at the pre-heat train of a CDU in Tehran oil refin-
ery, was employed to evaluate the CFD model. The data set
1. Diffusion of bulk species through the fouled layer (second group included inlet and outlet temperatures for both shell-and-tube
in the diffusion category). sides, crude volume flow rate in tube side, crude composition
2. Reactions of bulk species on the tube surface based on Eq. (9). and also cumulative time for the first 3 months from last overhaul.
3. Diffusion of the reaction products (fouled species) through the Having these plant data, calculation of the fouling resistance was
fouled layer to return back to the top of the fouled layer (third conducted based on the procedure illustrated in Fig. 3.
group in the diffusion category). According to this procedure, fouling behavior for the crude oil
4. Very low diffusion of fouled species (saltw and coke) through pre-heater is obtained as illustrated in Fig. 4.
the petroleum together with very high apparent viscosities for Normal operating conditions of the pre-heater, presented in Ta-
them to hinder their separation from the fouled layer and sub- ble 2, was chosen to run the CFD model.
sequently thickening of the fouled layer. Employing the above operating conditions, velocity distribution
along the tube obtained for different simulation periods is illus-
Since fouling phenomenon generally occurs in the boundary trated in Fig. 5. The zero velocity regions represent the fouling
layer, the shape and thickness of the boundary layer influences layer formed on the wall. It can be observed that the initial fouling
fouling behavior. A fully developed flow is, therefore, essential to layers are developed after about 9 days (7.92e5 s) and the thick-
generate an accurate boundary layer. Once the boundary condi- ness of fouling layer is increased as time progresses.
tions were set, unsteady turbulent flow equations for non-reacting Contours of the coke concentration stuck on the tube wall and
case were solved until the residuals of axial velocity were settled the corresponding velocity profile in three sections of the compu-
and fully developed flow field was reached. The residuals of veloc- tational domain are shown in Fig. 6. The contours of deposited salts
ity components were considered to be 1e7 in order to obtain a (not shown here) are qualitatively as the same. It can be seen that
fully developed flow in the 0.5 m tube long. The converged non- in the inlet section of the tube no severe fouling occurred even for
reactive case was, then, used as a starting point (initial guess) for the long operation periods. However, maximum amount of fouling
the solution of the species balance equations in the reactive case. is formed in the outlet section of the tube due to the more resi-

Fig. 3. Equation-based procedure for calculation of fouling resistance. (See the above mentioned references for further information.)
M. Bayat et al. / Energy Conversion and Management 64 (2012) 344–350 349

Table 2 In Fig. 7 simulation results of the CFD model is evaluated


Simulation conditions of a pre-heater in the CDU of Tehran oil refinery.
against the plant data. It represents a comparison between the
Operating conditions Value experiment and the predictions of the CFD model. It should be
Average crude inlet temperature (K) 490 noted that the experimental fouling data points in Fig. 7 are related
Average shell-side inlet temperature (K) 538 to both shell-and-tube sides of the exchanger, since they were cal-
Average crude velocity (m s1) 0.79 culated based on the procedure depicted in Fig. 3. As a conse-
Average shell-side HTC (W m2 K1) 455 quence, the CFD model is evaluated as a total fouling predictor,
Asphaltene mass fraction 0.02
Salt mass fraction 0.01
applying the previous well-tuned parameters (viscosities and
molecular diffusions).
At first glance, it seems that the predictability of the CFD model
dence time available for the reactants. As fouling progresses, the is poor in the induction period of the fouling. It stems from the fact
available cross section area is decreased and therefore, the maxi- that, at the induction period deposition of foulants on the tube wall
mum fluid velocity is increased. causes escalation in both wall thermal resistance and available

Fig. 5. Contours of velocity profile along the tube in various operation periods.

6.84e-05 x=0 x=30 x=235 x=265 x=470 x=500

6.16e-05 Time =2.44e5 s

5.47e-05

4.79e-05 Time =7.92e5 s

4.10e-05
Time =1.58e6 s
3.42e-05

2.74e-05
Time =2.37e6 s
2.05e-05

1.37e-05
Time =6.33e6 s
6.84e-06

0.00e+00
0.015
t=2.44e5 s
t=7.92e5s
0.01 t=1.58e6 s
t=2.37e6 s
t=6.33e6 s
Tube diameter (m)

0.005

0
0 0.2 0.4 0.6 0.8 1 1.2 0 0.5 1 1.5 0 0.5 1 1.5 2

-0.005

-0.01

-0.015
Velocity (m/s) Velocity (m/s) Velocity (m/s)

Fig. 6. Contours of coke concentration and velocity profiles along the tube in various operation periods.
350 M. Bayat et al. / Energy Conversion and Management 64 (2012) 344–350

2
fouling. In addition, the CFD model has three distinguishing new
features compared to the conventional threshold fouling models.
Induction period Developing period It can consider the effects of chemical components, shell-side
Fouling Resistance (m2 K kW-1)

HTC and turbulent flow on the crude oil fouling rate. Hence, the
1.5 developed CFD model is expected to be helpful for evaluating crude
oil fouling rates under new operating conditions.

1 6. Acknowledgements
Experiment
CFD model
The authors would like to thank Tehran Refinery Oil Company
for providing the valuable data to conduct this research.
0.5

References

0 [1] Panchal CB. Fouling mitigation in the petroleum industry: where do we go


0 500 1000 1500 2000 from here? In: Proceeding of engineering foundation conference on fouling
mitigation in industrial heat exchangers, San Luis Obispo, California; 1995.
Time (hr) [2] Panchal CB, Kuru WC, Liao CF, Ebert WA, Palen JW. Threshold condition for
crude oil fouling. In: Proceedings of understanding heat exchanger fouling and
Fig. 7. Prediction of the CFD model from plant data related to a pre-heater in the its mitigation, Barga, Italy; 1997.
CDU of Tehran oil refinery. [3] Polley GT, Wilson DI, Yeap BL, Pugh SJ. Evaluation of laboratory crude oil
threshold fouling data for application to refinery pre-heat trains. Appl Therm
Eng 2002;22:777–88.
[4] Yeap BL, Wilson DI, Polley GT, Pugh SJ. Mitigation of crude oil refinery heat
heat transfer area [24]. In other words, deposition of the first layer
exchanger fouling through retrofits based on thermohydraulic fouling models.
of the fouled species on the clean tube wall lead to an increase in Chem Eng Res Des 2004;84:53–71.
surface roughness and eventually increases heat transfer surface. [5] Vahdat Azad A, Ghaebi H, Amidpour M. Novel graphical approach as fouling
Therefore, at the induction period no significant reduction in the pinch for increasing fouling formation period in heat exchanger network (HEN)
state of the art. Energy Convers Manage 2011;52:117–24.
crude inlet/outlet temperature differences could be traced. Since, [6] Herz A, Malayeri MR, Müller-Steinhagen H. Fouling of roughened stainless
the fouling data points presented in Fig. 7 were calculated accord- steel surfaces during convective heat transfer to aqueous solutions. Energy
ing to the procedure depicted in Fig. 3, which was based on the in- Convers Manage 2008;49:3381–6.
[7] Aminian J, Shahhosseini S. Evaluation of ANN modeling for prediction of crude
let/outlet temperature difference, at the induction period the oil fouling behavior. Appl Therm Eng 2008;28:668–74.
increase in fouling resistance could not be observed in the ex- [8] Aminian J, Shahhosseini S. Neuro-based formulation to predict fouling
tracted plant data. However, the developed CFD model is free of threshold in crude pre-heaters. Int Commun Heat Mass Transfer
2009;36:525–31.
this deficiency, since the calculation of fouling resistance using [9] Radhakrishnan VR, Ramasamy M, Zabiri H, Do Thanh V, Tahir NM, Mukhtar H,
the developed CFD model is not based on the reduction of inlet/ et al. Heat exchanger fouling model and preventive maintenance scheduling
outlet temperature difference. Therefore, simulation results shown tool. Appl Therm Eng 2007;27:2791–802.
[10] Sanaye S, Niroomand B. Simulation of heat exchanger network (HEN) and
in Fig. 7 indicate that the developed CFD model is capable of trac-
planning the optimum cleaning schedule. Energy Convers Manage
ing fouling formation in the induction period. As a consequence, 2007;48:1450–61.
the CFD model could be applied to other operating conditions to [11] Rodriguez C, Smith R. Optimization of operating conditions for mitigating
fouling in heat exchanger networks. Chem Eng Res Des 2007;85:839–51.
investigate the details of the effect of hydrodynamics, temperature
[12] Brahim F, Augustin W, Bohnet M. Numerical simulation of the fouling process.
fluctuations and component concentrations on the fouling rate of Int J Therm Sci 2003;42:323–34.
crude oil in the industrial pre-heaters even at the induction period [13] Walker P, Sheikholeslami R. Assessment of the effect of velocity and residence
of fouling. time in CaSO4 precipitating flow reaction. Chem Eng Sci 2003;58:3807–16.
[14] Zhang J, Li A. CFD simulation of particle deposition in a horizontal turbulent
duct flow. Chem Eng Res Des 2008;86:95–106.
5. Conclusion [15] Zhang J, Li A, Li D. Modeling deposition of particles in typical horizontal
ventilation duct flows. Energy Convers Manage 2008;49:3672–83.
[16] Menter F, Esch T, Kubacki S. Transition modeling based on local variables. In:
A two dimensional CFD model has been developed to predict 5th International symposium of engineering turbulence modeling and
crude oil fouling behavior in an industrial shell-and-tube heat ex- measurements, Mallora, Spain; 2002.
[17] Launder BE, Spalding DB. Lectures in mathematical models of
changer. Components of the crude oil were assumed to be asphal-
turbulence. London, England: Academic Press; 1972.
tene, coke and salt characterized by their thermo-physical [18] Wilcox DC. Turbulence modeling for CFD. La Canada, CA: DCW Industries
properties. It was found that the molecular diffusion coefficients Press; 1994.
play an important role in the modeling of crude oil fouling behav- [19] Patankar SV. Numerical heat transfer and fluid flow. Taylor & Francis Press;
1980.
ior. Therefore, the binary diffusion coefficients were categorized [20] Ostlund JA, Wattana P, Nyden M, Fogler HS. Characterization of fractionated
into five different groups based on a conceptual procedure of depo- asphaltenes by UV–vis and NMR self-diffusion spectroscopy. J Colloid Interface
sition/separation phenomena. The effects of two competing factors Sci 2004;271:372–80.
[21] Xie K, Karan K. Kinetics and thermodynamics of asphaltene adsorption on
were considered to determine the probability of adhesion of reac- metal surfaces: a preliminary study. Energy Fuels 2005;19:1252–60.
tion products to the tube wall. These factors include the apparently [22] Sinnott RK. Coulson and Richardson’s Chemical Engineering, vol. 6. fourth
high viscosity of the fouled species and the shear stress on the wall. ed. Oxford: Elsevier Press; 2005.
[23] Palen JW, Taborek J. Solution of shell side flow pressure drop and heat transfer
The predictability of the model was assessed against a set of plant by stream analysis method. Chem Eng Prog Symp 1969;65:53–63.
data extracted from an industrial shell-and-tube heat exchanger. [24] Bott TR. Fouling of heat exchangers. Amsterdam: Elsevier Press; 1995.
Simulation results indicated that the CFD model is capable of pre-
dicting fouling rate in both induction and developing periods of

View publication stats