Anda di halaman 1dari 2

PL 70 Protection Relay

Electric Motors and Generators

INGEPACTM PL70 offers protection for a wide variety of applications.

The PL70 family provides a cost effective comprehensive protection for general purposes. In addition
to the main protection and automation functions (overcurrent, voltage, breaker failure, frequency,
phase shift, field loss, autoreclose, synchrocheck), these devices offer other functions, such as
communications, event recording, logic programming, breaker monitoring, etc., making of these
devices a suitable solution for the automation of electric systems.

Protection functions
50/51 Three-phase overcurrent
50/51N Earth overcurrent
50/51R Residual overcurrent
52
74TC
74CC
46 Negative sequence overcurrent
(unbalance)
50 50R 50BF 51RL 46BC 46BC Broken conductor
37 Minimum current
3 49 Thermal image
51RL Rotor locked
48 Long start
51 48 66 51R 49 37 46 66 Starts per hour
87N Restricted earth protection
M 87N 40 Field loss
50N 51N
32 One phase maximum and minimum active
power, maximum reactive power and reverse
1
power
Breaker monitoring
74TC/CC trip and close circuit supervision
Openings, closures, kI2 counters
OPTIONAL Excessive number of trips alarm
Command failure
Pulsed and latched open and close controls
Data Acquisition Functions
Measurements historical report (maximum/
minimum)
Event, fault and oscilographic recorder
Statistical metering: Current (fundamental
74TC and sequences), power, demand maximeter
52 74CC Digital inputs and outputs
Software Communications
DB9 RS232 PROCOME protocol front port
All of the equipment in the INGEPACTM Up to 2 rear ports: RS232, RS485, Glass
1
family can be accessed using powerful Fibre Optic, Plastic Fibre Optic, Ethernet
software tools developed by Ingeteam and PROCOME, Modbus, DNP 3.0, IEC60870-5-
103 protocols
which run on Windows®. 32 40 Synchronisation
Application software specifically designed Via communications protocol or via
demodulated IRIG-B input.
for simple and user-friendly access to the 1 Local interface
equipment. Keypad + local display (2 rows x 8 characters)
SIPCON software running on Windows for PC,
3 front amd rear port access.

Functions depending on model


General Description
Main Features
Electromagnetic and
Insulation ∙∙ Cost-effective protection solution for small motors and specific generator applications
∙∙ Measurement of conducted ∙∙ Intuitive configuration and monitoring software supplied with the relay Automatic model detection, not requi-
radio-electric emissions in DC IEC60255-25/
ring previous configuration works to communicate with the device

The technical data in this catalogue is subject to change without prior notice. FY25IPTT01_B/0318
power port EN55022
∙∙ Measurement of radiated radio- IEC60255-25/ ∙∙ User-defined logic signals
electric emissions EN55022
∙∙ Digital inputs and outputs and programmable LED indicators
∙∙ Insulation resistance IEC60255-5
∙∙ Dielectric IEC60255-5
∙∙ Serial and Ethernet communication
∙∙ Impulse voltage IEC60255-5 ∙∙ Real time monitoring and recording of the parameters of the breaker
∙∙ Electrostatic discharges ∙∙ Events and faults recording
immunity IEC61000-4-2
∙∙ 4 setting groups for instantaneously adapting the settings to the machine conditions
∙∙ Radiated radiofrequency fields ENV 50204/IEC
immunity 61000-4-3 ∙∙ Synchronisation via demodulated IRIG-B or through communication protocols
∙∙ Electrical fast transients
immunity IEC61000-4-4
∙∙ Surge immunity IEC61000-4-5 Options
∙∙ Conducted disturbances
induced by radio-frequency
fields immunity IEC61000-4-6 ∙∙ Connections for pin or ring type terminals
∙∙ Power frequency magnetic
fields immunity IEC61000-4-8
∙∙ Field interfaces
∙∙ Pulse magnetic fields immunity IEC61000-4-9 Configuration Digital inputs Digital outputs Others
∙∙ Damped oscillatory magnetic
fields immunity IEC61000-4-10 0 2 6 -
∙∙ Damped oscillatory waves IIEC61000-4-18/ 1 8 11 -
immunity IEC60255-22-1
2 7 11 IRIG-B
∙∙ DC supply voltage polarity
inversion, variations, dips and IEC61000-4-29/
interruptions immunity IEC60255-11
∙∙ Power supply: 12 Vdc; 24/48 Vdc; 125/220 Vdc; 220 Vac
∙∙ Power frequency immunity IEC60255-22-7
∙∙ Surge Withstand Capability
∙∙ Power supply voltage measurement
(SWC) IEEE C37.90-1 ∙∙ Communications ports: All of the devices have a front RS232 port for local access and additionally: 1 serial;
2 serial; 1 serial + 1 Ethernet
Climatic ∙∙ Communication ports connection types
∙∙ Cold IEC 60068-2-2
Serial: RS232, RS485, Glass Fibre Optic, Plastic Fibre Optic
∙∙ Dry heat IEC 60068-2-1
∙∙ Damp heat, steady state IEC 60068-2-78 Ethernet: RJ45
∙∙ Change of temperature (thermal ∙∙ IP54 front lid
shock) IEC 60068-2-14
∙∙ Models by protection functions:
PL70PC (3xV + 1xI): 40, 74TC/CC
Mechanical
∙∙ Vibration IEC60255-21-1
PL70PO (1xI + 1xV): 32, 74TC/CC
∙∙ Shock and bump IEC 60255-21-2 PL70MO (3xI phases + 1xI neutral): 50/51, 50/51N, 50/51R, 49, 46, 46BF,87N, 50RL, 37, 48, 66,
∙∙ Seismic IEC 60255-21-3 74TC/CC

Applications

∙∙ Motor protection
∙∙ Power protection for interconnection and generators
∙∙ Field loss protection for synchronous motors

Anda mungkin juga menyukai