Anda di halaman 1dari 11

Punching Shear Calculation ACI 318-08

Input data

Concrete compressive strength(fc) 24 Mpa


Modulus of Elasticity (Ec) 23025.20 Mpa
Modulus of Elasticity (Es) 200000.00 Mpa
Grade of steel (fs) 420.00 Mpa
Column short side 600 mm
Column long side 600 mm
Slab thickness 700 mm
Cover to C.G of reinforcement 75 mm
Effective depth (d) 625 mm
Strength reduction Factor, φ 0.75
Column Location Case

Interior column *Select a case

Column punching loads

Axial Force (Pu) 1530 KN


Mu1 (Bending perpendicular to short side) 0 KN.m
Mu2 (Bending perpendicular to long side) 0 KN.m

Calculations

b0 (Critical Perimeter) 4900 mm


Area of critical section (Ac) 3062500 mm2
Ratio of long side to short side of column(βc) 1
αs (Constant used to compute shear in slabs) 40
Properties for section resisiting Mu1
b1 (length of critical section side parallel to Mu1) 1225 mm
b2 (length of critical section side parallel to Mu2) 1225 mm
Modulus of critical section resisting Mu1 (J/c) 1331901041.66667 mm3
Modulus of critical section resisting Mu1 (J/c') 1331901041.66667 mm3
Properties for section resisiting Mu2
b1 (length of critical section side parallel to Mu2) 1225 mm
b2 (length of critical section side parallel to Mu1) 1225 mm
Modulus of critical section resisting Mu2 (J/c) 1331901041.66667 mm3
Modulus of critical section resisting Mu2 (J/c') 1331901041.66667 mm3
Unbalanced moment transfer factors
Transfer factor for Mu1
Flexure Factor (Yf) 0.60
Shear Factor (Yv) 0.40
Transfer factor for Mu2
Flexure Factor (Yf) 0.60
Shear Factor (Yv) 0.40

Results

Applied stresses
Vp 0.500 Mpa
VMu1 0.000 Mpa
VMu2 0.000 Mpa
Total Applied Stress 0.500 Mpa

Allowable Stresses

φVc1 1.87 Mpa


φVc2 2.17 Mpa
φVc3 1.21 Mpa
Allowable stress, Vn1=φVcmin 1.212 Mpa *Without shear reinforcemen
Maxium shear strength allowed,Vn1 1.837 Mpa *With shear reinforcement e
Maxium shear strength allowed,Vn1 2.205 Mpa *With shear heads
Punching Ratio 0.41 No shear reinforcement required

Design for shear reinforcement

Shear strength by provision of bars, wires and multiple leg stirrups

Spacing of shear stirrups 150 mm *Spacing shall not be les


No of legs 4
Shear strength carried by concrete, vc 0.62 Mpa
Shear strength carried by stirrups, vs -0.17 Mpa
Area of stirrups required, Av -292 mm2
No of column shearing sides ,N 4
Area of stirrups needed per leg per side -18.23 mm2
Provide φ #N/A @
b0 αs
Interior column 4900 40
Edge column (free edge along long side) 3050 30
Edge column (free edge along short side) 3050 30
Corner Column 1825 20
ithout shear reinforcement
ith shear reinforcement except shear heads
ith shear heads
ement required

*Spacing shall not be less than 'd/2'

150 4 Legged
Mu1 Mu2
b1 b2 J/c J/c' J/c J/c' N
1225 1225 1331901041.66667 1331901041.67 1331901042 1331901042 4
1225 912.5 895638020.833333 895638020.833 826057943 826057943 3
912.5 1225 775230540.097032 330946370.919 890075601 510101806 3
912.5 912.5 515055338.541667 171685112.847 515055339 171685113 2
Punching Shear Calculation ACI 318-08 Valid for interior circular columns

Input data

Concrete compressive strength(fc) 24 Mpa


Modulus of Elasticity (Ec) 23025.20 Mpa
Modulus of Elasticity (Es) 200000.00 Mpa
Grade of steel (fs) 400.00 Mpa
Column Diameter (D) 500 mm
Slab thickness 300 mm
Cover to C.G of reinforcement 35 mm
Effective depth (d) 265 mm
Strength reduction Factor, φ 0.85
Column Location Case

Edge column *Select a case

Column punching loads

Axial Force (Pu) 345 KN


Mu 169 KN.m

Calculations

b0 (Critical Perimeter) 1746.59


Area of critical section (Ac) 462845.66
Ratio of long side to short side of column(βc) 1.00
αs (Constant used to compute shear in slabs) 30
Properties for section resisiting Mu
b0 1746.59
Modulus of critical section resisting Mu (J/c) 128006387.98

Unbalanced moment transfer factors


Transfer factor for Mu
Flexure Factor (Yf) 0.60
Shear Factor (Yv) 0.40

Results

Applied stresses
Vp 0.745 Mpa
VMu 0.528 Mpa
Total Applied Stress 1.273 Mpa
Allowable Stresses

φVc1 2.12 Mpa


φVc2 2.26 Mpa
φVc3 1.37 Mpa
Allowable stress, Vn1=φVcmin 1.374 Mpa
Maxium shear strength allowed,Vn1 1.837 Mpa
Maxium shear strength allowed,Vn1 2.205 Mpa

Punching Ratio 0.93 No shear reinforcement required


b0
Interior column 2403.32
Edge column 1746.59
Corner Column 1145.76
ment required
Mu1
αs b1 b2 J/c J/c' J/c J/c' N J/c J/c'
40 #REF! #REF! #REF! #REF! #REF! #REF! 4 #REF! #REF!
30 #REF! #REF! #REF! #REF! #REF! #REF! 3 #REF! #REF!
20 #REF! #REF! #REF! #REF! #REF! #REF! 2 #REF! #REF!
Mu2
J/c J/c' N
#REF! #REF! 4
#REF! #REF! 3
#REF! #REF! 2

Anda mungkin juga menyukai