Anda di halaman 1dari 6

Sleeves Movement Record Sheet

for

Belayim Well 112-86 Digital HydraulicsTM Completion

Rev. 0

PREPARED BY

Simone Palmieri
Project Engineer

WellDynamics International Ltd


Italian Branch Office
Via Nazionale Adriatica Nord, 557
65125 Pescara

Phone: +39 085 75957


Fax: +39 085 4714765
Mob.: +39 348 3705186

This document is confidential and is the property on WellDynamics International Ltd. It may not be copied, reproduced or disclosed in any form without the
written consent of WellDynamics. WellDynamics intends to protect this confidential document under the copyright laws as unpublished work, or in the event of
inadvertent or deliberate publication as a published work of WellDynamics. Copyright 2001 by WellDynamics

Page 1 of 6 16/05/2003
Belayim 112-86 SmartWell® Completion Sleeve Movement Record Sheet

Sleeves actuation before Preliminary Functional Test in front of customer


(without Flat-pack)
Client ENI-Agip / Petrobel Well No. Belayim 112-86
Date 25/05/03 Test Location Halliburton base in Cairo
Client Engineer None WellDynamics Simone Palmieri
Sheet number 1 Engineer

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


7 1 N/A X
Digital Hydraulics
Decoder ‘A’ 2 N/A X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


6 1 N/A X
Digital Hydraulics
Decoder ‘B’ 2 N/A X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


5 1 N/A X
Digital Hydraulics
Decoder ‘C’ 2 N/A X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


4 1 N/A X
Digital Hydraulics
Decoder ‘D’ 2 N/A X

Sleeves actuation before Preliminary Functional Test in front of customer


(without Flat-pack)
Client ENI-Agip / Petrobel Well No. Belayim 112-86
Date 27/05/03 Test Location Halliburton base in Cairo
Client Engineer None WellDynamics Steve Ewens
Sheet number 2 Engineer

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


7 3 N/A X
Digital Hydraulics
Decoder ‘A’ 4 N/A X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


6 3 N/A X
Digital Hydraulics
Decoder ‘B’ 4 N/A X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


5 3 N/A X
Digital Hydraulics
Decoder ‘C’ 4 N/A X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


4 3 N/A X
Digital Hydraulics
Decoder ‘D’ 4 N/A X
Written by Simone Palmieri Page 2 of 6 16/05/2003
Belayim 112-86 SmartWell® Completion Sleeve Movement Record Sheet

Sleeves actuation during Preliminary Functional Test in front of customer


(without Flat-pack)
Client ENI-Agip / Petrobel Well No. Belayim 112-86
Date 27/05/03 Test Location Halliburton base in Cairo
Client Engineer Stefano Pierfelici WellDynamics Simone Palmieri
Sheet number 3 Engineer

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


7 5 N/A X
Digital Hydraulics
Decoder ‘A’ 6 N/A X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


5 5 N/A X
Digital Hydraulics
Decoder ‘C’ 6 N/A X

Sleeves actuation after Preliminary Functional Test


(without Flat-pack)
Client ENI-Agip / Petrobel Well No. Belayim 112-86
Date 27/05/03 Test Location Halliburton base in Cairo
Client Engineer None WellDynamics Simone Palmieri
Sheet number 4 Engineer

Operation No. Chart No. Open Closed Unknown


5 N/A X
Sub-assembly No.
6 6 N/A X
Digital Hydraulics
Decoder ‘B’ 7 N/A X

8 N/A X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


4 5 N/A X
Digital Hydraulics
Decoder ‘D’ 6 N/A X

Written by Simone Palmieri Page 3 of 6 16/05/2003


Belayim 112-86 SmartWell® Completion Sleeve Movement Record Sheet

Sleeves Movement Record during Stack-up Test before moving to Well Site
(through 11,000 ft Flat-pack)
Client ENI-Agip / Petrobel Well No. Belayim 112-86
Date 15/07/03 Test Location Halliburton base in Cairo
Client Engineer None WellDynamics Simone Palmieri
Sheet number 5 Engineer

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


7 7 A-01 X
Digital Hydraulics
Decoder ‘A’ 8 A-02 X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


6 9 B-01 X
Digital Hydraulics
Decoder ‘B’ 10 B-02 X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


5 7 C-01 X
Digital Hydraulics
Decoder ‘C’ 8 C-02 X

Operation No. Chart No. Open Closed Unknown


7 D-01 X
Sub-assembly No.
4 8 D-02 X
Digital Hydraulics
Decoder ‘D’ 9 D-03 X

10 D-04 X

Back-up HV-ICV Operation No. Chart No. Open Closed Unknown


1 E-01 X
Digital Hydraulics
Decoder ‘E’ 2 E-02 X

Written by Simone Palmieri Page 4 of 6 16/05/2003


Belayim 112-86 SmartWell® Completion Sleeve Movement Record Sheet

Sleeves Movement Record during Completion Deployment Lower Part


(through 11,000 ft Flat-pack and definitive sub-assemblies configuration)
Client ENI-Agip / Petrobel Well No. Belayim 112-86
Date 08-09-10-11/11/03 Test Location Well site
Client Engineer Youssef/Mahmoud WellDynamics Simone Palmieri
Sheet number 6 Engineer

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


7 9 A-03 X
Digital Hydraulics
Decoder ‘A’ 10 A-04 X

Operation No. Chart No. Open Closed Unknown


Sub-assembly No.
11 B-03 X
6
Digital Hydraulics 12 B-04 X
Decoder ‘B’
13 B-05 X

Operation No. Chart No. Open Closed Unknown


Sub-assembly No.
9 C-03 X
5
Digital Hydraulics 10 C-04 X
Decoder ‘C’
11 C-05 X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


4 11 D-05 X
12 D-06 X
Digital Hydraulics
Decoder ‘D’ 13 D-07 X

Written by Simone Palmieri Page 5 of 6 16/05/2003


Belayim 112-86 SmartWell® Completion Sleeve Movement Record Sheet

Sleeves Movement Record during Completion Deployment Hanger Landed

Client ENI-Agip / Petrobel Well No. Belayim 112-86


Date 18-19/11/03 Test Location Well site
Client Engineer Hassan/Youssef WellDynamics Simone Palmieri
Sheet number 7 Engineer

Operation No. Chart No. Open Closed Unknown


Sub-assembly No.
11 A-05 X
7
Digital Hydraulics 12 A-06 X
Decoder ‘A’
13 A-07 X

Sub-assembly No. Operation No. Chart No. Open Closed Unknown


6 14 B-06 X
Digital Hydraulics
Decoder ‘B’ 15 B-07 X

Operation No. Chart No. Open Closed Unknown


Sub-assembly No.
12 C-06 X
5
Digital Hydraulics 13 C-07 X
Decoder ‘C’
14 C-08 X

Operation No. Chart No. Open Closed Unknown


Sub-assembly No.
14 D-08 X
4
Digital Hydraulics 15 D-09 X
Decoder ‘D’
16 D-10 X

ICV Levels II, III, IV left OPEN.


ICV Level IIA left CLOSED.

Written by Simone Palmieri Page 6 of 6 16/05/2003