Anda di halaman 1dari 11

DRAWING TITLE:

DESIGN NOTE:
GSKY GREEN WALL PANELS *STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
CONCRETE WALL STRUCTURE / INTERIOR OR EXTERIOR *WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
3D VIEW SECTION DETAIL *WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
PLAN DETAIL FASTENER DETAIL *EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
DRAWING # *GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
1-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com

CONCRETE WALL WITH


3/8" DIA SS WEDGE ANCHOR
SMOOTH SURFACE

GSKY SS FRAME WATERPROOFING

2"

1 1/2"
6 1/2"

5"
GSKY TOP TRIM CONCRETE WALL

GSKY TRIM MOUNTING ANGLE


SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
3"
WATERPROOFING GSKY STANDARD STAINLESS OR ALUMINUM GSKY
4" 11 7/8" TYP.
GREEN WALL PANEL SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

GSKY SIDE TRIM


PLAN DETAIL / CONCRETE WALL
2 SCALE 3/4" - 1'-0" (FILE # 1-p-2)

GSKY STANDARD GSKY SS FRAME 6 1/2" CONCRETE WALL


GREEN WALL PANEL STAINLESS OR ALUMINUM GSKY TRIM MOUNTING
GSKY TOP TRIM SECURE 5" ANGLE
3/8" DIA SS WEDGE
INTO TRIM MOUNTING ANGLE
ANCHOR

4"
3"
CONCRETE WALL NEOPRENE WASHER
WITH SMOOTH BETWEEN WALL AND
3/8" DIA SS WEDGE ANCHOR

MIN 2" EMBED


SURFACE GSKY FRAME

GSKY FRAME
GSKY STANDARD GSKY IRRIGATION
GREEN WALL PANEL DRIP LINE WATERPROOFING

1 1/2"
2"

11 7/8"
GSKY SS FRAME

SEE 8-p-2 FOR DRAIN


DETAIL

3/8" DIA SS WEDGE


FASTENER DETAIL / CONCRETE WALL
ANCHOR 4 SCALE 3" - 1'-0" (FILE # 1-p-4)

WATERPROOFING

3D VIEW / CONCRETE WALL SECTION DETAIL / CONCRETE WALL


1 SCALE 3/8" - 1'-0" (FILE # 1-p-1) 3 SCALE 3/4" - 1'-0" (FILE # 1-p-3)
DRAWING TITLE:
DESIGN NOTE:
GSKY GREEN WALL PANELS *STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
CMU WALL STRUCTURE / INTERIOR OR EXTERIOR *CMU VOID SPACE MUST BE FILLED WITH MORTAR FOR ANCHORING
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
3D VIEW SECTION DETAIL *ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
PLAN DETAIL FASTENER DETAIL *WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*EMBEDDED PIPE OR CONDUIT LOCATIONS MUST BE INDICATED TO GSKY
DRAWING # *TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST *GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
VANCOUVER, BC V6B 2V2
2-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com

3/8" DIA CONCRETE CMU WALL (VOID MUST BE


ANCHOR FILLED)

GSKY SS FRAME WATERPROOFING

2"

1 1/2"
GSKY TOP TRIM
CMU WALL (VOID MUST BE FILLED)

6 1/2"

5"
GSKY TRIM MOUNTING ANGLE
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
3"
GSKY STANDARD STAINLESS OR ALUMINUM GSKY
4" 11 7/8" TYP.
GREEN WALL PANEL SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE
GSKY SIDE TRIM

WATERPROOFING

PLAN DETAIL / CMU WALL


2 SCALE 3/4" - 1'-0" (FILE # 2-p-2)

GSKY STANDARD GSKY SS FRAME


GREEN WALL PANEL CMU WALL WITH
6 1/2" FILLED VOID
STAINLESS OR ALUMINUM GSKY TRIM MOUNTING
GSKY TOP TRIM SECURE 5" ANGLE
3/8" DIA SS CONCRETE
INTO TRIM MOUNTING ANGLE
ANCHOR
3/8" DIA CONCRETE ANCHOR

3"
4"
SEE 8-p-1 FOR NEOPRENE WASHER
CMU WALL (VOID
DRAIN DETAIL BETWEEN WALL AND
MUST BE FILLED)
GSKY FRAME

GSKY FRAME
GSKY STANDARD GSKY IRRIGATION
GREEN WALL PANEL DRIP LINE WATERPROOFING

1 1/2"
2"

11 7/8"
GSKY SS FRAME

3/8" DIA CONCRETE


FASTENER DETAIL / CMU WALL
ANCHOR 4 SCALE 3" - 1'-0" (FILE # 2-p-4)

WATERPROOFING

3D VIEW / CMU WALL SECTION DETAIL / CMU WALL


1 SCALE 3/8" - 1'-0" (FILE # 2-p-1) 3 SCALE 3/4" - 1'-0" (FILE # 2-p-3)
DRAWING TITLE:
DESIGN NOTE:
GSKY GREEN WALL PANELS *STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
STUD WALL STRUCTURE / INTERIOR OR EXTERIOR *3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
*BLOCKING AT GSKY FRAME SCREW LOCATIONS MAY BE REQUIRED CHECK WITH PROJECT ENGINEER
3D VIEW SECTION DETAIL *STUD LOCATION MUST BE IDENTIFIED ON THE AS-BUILT DRAWING
PLAN DETAIL FASTENER DETAIL *GREEN WALL CAN BE RECESSED AT INDOOR WALL (NOTE THAT GUTTER WILL EXTEND OUT; SEE 8-p-1 FOR DETAIL)
*WATERPROOFING IS REQUIRED TO BE APPLIED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
DRAWING # *ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST *WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
VANCOUVER, BC V6B 2V2
3-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

2x6 BLOCKING AT GSKY FRAME


SCREW LOCATION MAYBE
1/4" DIA WOOD OR WOOD OR METAL STUD REQUIRED (CHECK WITH
METAL SCREW WALL STRUCTURE PROJECT ENGINEER)
GSKY SS FRAME
3/4" PLYWOOD BEHIND GREEN
WALL

2" WATERPROOFING

1 1/2"
SEE 10-p AND 11-p FOR
GSKY TOP TRIM STUD WALL STRUCTURE IRRIGATION DETAIL

5"
WALL FINISH TO MAKE GSKY TRIM MOUNTING ANGLE
RECESSED GREEN 3"
GREEN WALL CAN BE
WALL OPTION RECESSED INTO GSKY STANDARD STAINLESS OR ALUMINUM GSKY
WALL FINISH 4" 11 7/8" TYP.
GREEN WALL PANEL SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

GSKY SIDE TRIM 2x6 BLOCKING AT GSKY FRAME


SCREW LOCATIONS MAY BE
REQUIRED (CHECK WITH PLAN DETAIL / STUD WALL
PROJECT ENGINEER)
2 SCALE 3/4" - 1'-0" (FILE # 3-p-2)

GSKY STANDARD
GREEN WALL PANEL 2x6 BLOCKING AT GSKY
3/4" PLYWOOD BEHIND GREEN FRAME SCREW LOCATION
WALL MAYBE REQUIRED (CHECK
6 1/2" WITH PROJECT ENGINEER)
STAINLESS OR ALUMINUM GSKY TRIM MOUNTING
GSKY TOP TRIM SECURE 5" ANGLE
WATERPROOFING INTO TRIM MOUNTING ANGLE
1/4" DIA SS WOOD OR
SEE 8-p-1 FOR METAL SCREW

3"
4"
DRAIN DETAIL
WOOD OR METAL STUD NEOPRENE WASHER
1/4" DIA WOOD OR METAL
WALL STRUCTURE BETWEEN WALL AND
SCREW
GSKY FRAME
3/4" PLYWOOD BEHIND
GSKY STANDARD GSKY IRRIGATION GREEN WALL
GREEN WALL PANEL DRIP LINE
GSKY FRAME

GSKY SS FRAME GSKY SS FRAME WATERPROOFING

11 7/8"
2x6 BLOCKING AT GSKY

1 1/2"
FRAME SCREW LOCATION
MAYBE REQUIRED (CHECK 2"
WITH PROJECT ENGINEER)

3/4" PLYWOOD
BEHIND GREEN WALL

1/4" DIA WOOD OR


FASTENER DETAIL / STUD WALL
METAL SCREW 4 SCALE 3" - 1'-0" (FILE # 3-p-4)

WATERPROOFING

3D VIEW / STUD WALL SECTION DETAIL / STUD WALL


1 SCALE 3/8" - 1'-0" (FILE # 3-p-1) 3 SCALE 3/4" - 1'-0" (FILE # 3-p-3)
DRAWING TITLE:
DESIGN NOTE:
GSKY GREEN WALL PANELS *STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
*WALL SURFACE MUST BE SMOOTH
STEEL WALL STRUCTURE / INTERIOR OR EXTERIOR *HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT
*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
3D VIEW SECTION DETAIL *ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
PLAN DETAIL FASTENER DETAIL *WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
*TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
DRAWING # *GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
4-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com

STEEL STRUCTURE BACK COVER

INSULATION AS REQUIRED
1/4" DIA SS SELF BY GSKY
TAPPING SCREW
HORIZONTAL STEEL MEMBER
2" AT GSKY FRAME SCREW

1 1/2"
GSKY SS FRAME LOCATIONS BY OTHERS

GSKY TOP TRIM

6 1/2"

5"
INSULATION AS REQUIRED

GSKY TRIM MOUNTING ANGLE


SEE 10-p AND 11-p FOR
STEEL STRUCTURE
IRRIGATION DETAIL
3"
GSKY STANDARD STAINLESS OR ALUMINUM GSKY
4" 11 7/8" TYP.
GREEN WALL PANEL SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

GSKY SIDE TRIM BACK COVER

PLAN DETAIL / STEEL WALL


2 SCALE 3/4" - 1'-0" (FILE # 3-p-2)

GSKY STANDARD GSKY SS FRAME


GREEN WALL PANEL 1/4" DIA SS SELF
6 1/2" TAPPING SCREW
STAINLESS OR ALUMINUM GSKY TRIM MOUNTING
GSKY TOP TRIM SECURE 5" ANGLE
INTO TRIM MOUNTING ANGLE NEOPRENE WASHER
BETWEEN WALL AND

4"
3"
1/4" DIA SS SELF TAPPING GSKY FRAME
SEE 8-p-3 FOR SCREW STEEL STRUCTURE
DRAIN DETAIL HORIZONTAL STEEL
MEMBER AT GSKY FRAME
SCREW LOCATIONS
GSKY STANDARD GSKY IRRIGATION
HORIZONTAL STEEL MEMBER DRIP LINE
GREEN WALL PANEL
AT GSKY FRAME SCREW GSKY FRAME
LOCATIONS

1 1/2"
2"

11 7/8"
GSKY SS FRAME

SOLID GROUND FINISH FOR BACK COVER


MAINTENANCE ACCESS BASED
ON THE SIZE OF GREEN WALL

1/4" DIA SS SELF


FASTENER DETAIL / STEEL WALL
TAPPING SCREW 4 SCALE 3" - 1'-0" (FILE # 4-p-4)

HORIZONTAL STEEL
MEMBER AT GSKY
FRAME SCREW
LOCATIONS

3D VIEW / STEEL WALL SECTION DETAIL / STEEL WALL


1 SCALE 3/8" - 1'-0" (FILE # 4-p-1) 3 SCALE 3/4" - 1'-0" (FILE # 3-p-3)
DRAWING TITLE:

GSKY GREEN WALL PANELS DESIGN NOTE:


*STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
DOUBLE SIDED WALL STRUCTURE / INTERIOR OR EXTERIOR *WALL SURFACE MUST BE SMOOTH
3D VIEW SECTION DETAIL *HORIZONTAL STEEL MEMBER MUST LINE UP WITH GSKY FRAME SCREW LOCATIONS; ASK GSKY FOR CONSULTANT
*WATERPROOFING MAY BE REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
PLAN DETAIL FASTENER DETAIL *ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
*WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
DRAWING #
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST *TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
VANCOUVER, BC V6B 2V2 *GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS
5-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com

1/4" DIA SS SELF STAINLESS OR ALUMINUM GSKY


TAPPING SCREW SIDE TRIM SECURE INTO TRIM
MOUNTING ANGLE

GSKY STANDARD
GREEN WALL PANEL HORIZONTAL STEEL MEMBER
2" AT GSKY FRAME SCREW

1 1/2"
GSKY TOP TRIM GSKY SS FRAME LOCATIONS

6 1/2"

5"
STEEL STRUCTURE
GSKY TRIM MOUNTING ANGLE
SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
3"

4" 11 7/8" TYP.


GSKY SIDE TRIM

PLAN DETAIL / DOUBLE SIDED WALL


2 SCALE 3/4" - 1'-0" (FILE # 5-p-2)

GSKY STANDARD GSKY SS FRAME


GREEN WALL PANEL

6 1/2"
STAINLESS OR ALUMINUM GSKY TRIM MOUNTING
GSKY TOP TRIM SECURE 5" ANGLE
INTO TRIM MOUNTING ANGLE
1/4" DIA SS SELF

3"
SEE 8-p-3 FOR TAPPING SCREW

4"
STEEL STRUCTURE
DRAIN DETAIL
BY OTHERS

HORIZONTAL STEEL MEMBER


AT GSKY FRAME SCREW GSKY STANDARD GSKY IRRIGATION
LOCATIONS GREEN WALL PANEL DRIP LINE

11 7/8"
GSKY SS FRAME 1/4" DIA SS SELF
TAPPING SCREW

SOLID GROUND FINISH FOR NEOPRENE WASHER


MAINTENANCE ACCESS BASED BETWEEN WALL AND
ON THE SIZE OF GREEN WALL GSKY FRAME

HORIZONTAL STEEL
MEMBER AT GSKY FRAME
SCREW LOCATIONS
1/4" DIA SS SELF
TAPPING SCREW GSKY FRAME
BY GSKY

1 1/2"
2"
HORIZONTAL STEEL
MEMBER AT GSKY
FRAME SCREW
LOCATIONS BY OTHERS

3D VIEW / DOUBLE SIDED WALL SECTION DETAIL / DOUBLE SIDED WALL FASTENER DETAIL / DOUBLE SIDED WALL
1 SCALE 3/8" - 1'-0" (FILE # 5-p-1) 3 SCALE 3/4" - 1'-0" (FILE # 5-p-3) 4 SCALE 3" - 1'-0" (FILE # 5-p-4)
DRAWING TITLE:
DESIGN NOTE:
GSKY GREEN WALL PANELS *STRUCTURE TYPE SHOWN ON 1-p, 2-p, 3-p AND 4-p CAN BE USED
*STRUCTURE MUST SUPPORT 30 LB/SQ.FT SATURATED GSKY GREEN WALL SYSTEM
EIFS WALL STRUCTURE / INTERIOR OR EXTERIOR *WALL SURFACE MUST BE SMOOTH
*3/4" PLYWOOD MUST BE INSTALLED BEHIND GREEN WALL AREA
3D VIEW SECTION DETAIL *BLOCKING AT GSKY FRAME SCREW LOCATIONS MUST BE INSTALLED; CHECK WITH ENVELOPE CONSULTANT FOR THERMAL BRIDGE
PLAN DETAIL FASTENER DETAIL *WATERPROOFING IS REQUIRED (LIQUID OR SELF ADHESIVE TYPE IS RECOMMENDED)
*ADEQUATE LIGHTING MUST BE DESIGNED AND INSTALLED (FOR INTERIOR GREEN WALL)
DRAWING # *WALL MUST BE ACCESSIBLE FOR MAINTENANCE (LIFT ACCESS MAY BE REQUIRED)
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST *TRIM WIDTH MAY INCREASE DEPENDING ON LOCATION OF ZONE VALVES; SEE 9-p, 10-p AND 11-p FOR DETAIL
VANCOUVER, BC V6B 2V2
6-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

1/4" DIA WOOD OR


METAL SCREW CONCRETE WALL WITH
SMOOTH SURFACE

GSKY SS FRAME WATERPROOFING

3/4" PLYWOOD BEHIND BLOCKING MATERIAL TO


GREEN WALL SECURE GSKY FRAME
2"

1 1/2"
WALL FINISH

8 3/4"
6 1/2"
GSKY TOP TRIM CONCRETE STRUCTURE

GSKY TRIM MOUNTING ANGLE


SEE 10-p AND 11-p FOR
IRRIGATION DETAIL
3"
GSKY STANDARD STAINLESS OR ALUMINUM GSKY
4" 11 7/8" TYP.
GREEN WALL PANEL SIDE TRIM SECURE INTO TRIM
WATERPROOFING MOUNTING ANGLE

BLOCKING MATERIAL TO PLAN DETAIL / EIFS WALL


GSKY SIDE TRIM
SECURE GSKY FRAME BY 2 SCALE 3/4" - 1'-0" (FILE # 6-p-2)
OTHERS (CHECK WITH
BUILDING ENVELOPE
CONSULTANT FOR THERMAL
BRIDGE)
WALL FINISH
GSKY STANDARD
GREEN WALL PANEL 6 1/2"
EIFS SYSTEM STAINLESS OR ALUMINUM GSKY TRIM MOUNTING
GSKY TOP TRIM SECURE 5" ANGLE
INTO TRIM MOUNTING ANGLE
3/4" PLYWOOD BEHIND GREEN BLOCKING MATERIAL TO

3"
4"
WALL SECURE GSKY FRAME
SEE 8-p-4 FOR
DRAIN DETAIL
1/4" DIA WOOD OR METAL
1/4" DIA SS WOOD OR
SCREW
GSKY STANDARD GSKY IRRIGATION METAL SCREW
GREEN WALL PANEL DRIP LINE
WATERPROOFING
GSKY SS FRAME
BLOCKING MATERIAL TO

11 7/8"
SECURE GSKY FRAME
GSKY SS FRAME 3/4" PLYWOOD BEHIND
GREEN WALL NEOPRENE WASHER
BETWEEN WALL AND
EIFS SYSTEM GSKY FRAME
3/4" PLYWOOD BEHIND
GREEN WALL
CONCRETE WALL
WITH SMOOTH GSKY FRAME
SURFACE

1 1/2"
1/4" DIA WOOD OR 2"
METAL SCREW

WATERPROOFING

3D VIEW / EIFS WALL SECTION DETAIL / EIFS WALL FASTENER DETAIL / EIFS WALL
1 SCALE 3/8" - 1'-0" (FILE # 6-p-1) 3 SCALE 3/4" - 1'-0" (FILE # 6-p-3) 4 SCALE 3" - 1'-0" (FILE # 6-p-4)
DRAWING TITLE:

GSKY GREEN WALL PANELS


TYPICAL DETAILS / INTERIOR OR EXTERIOR
3D VIEW CORNER PANEL
CORNER TRIM GUTTER OVER OPENING
DRAWING #
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
7-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com

GSKY CORNER
CORNER TRIM
PANEL
MOUNTING
BRACKET 3' O/C
5"

6 3/4"

5"
STAINLESS OR GSKY CORNER
ALUMINUM GSKY PANEL MOUNTING
SEE 7-p-4 FOR
GUTTER OVER
11 7/8" TYP. 6 3/4" CORNER TRIM 11 7/8" TYP. 5" BRACKET
OPENING

PLAN DETAIL / CORNER TRIM PLAN DETAIL / CORNER PANEL


2 SCALE 1" - 1'-0" (FILE # 7-p-2) 3 SCALE 1" - 1'-0" (FILE # 7-p-3)

SEE 7-p-3 FOR GSKY


CORNER PANEL
DETAIL

STAINLESS OR ALUMINUM
SEE 7-p-2 FOR GSKY GSKY GUTTER DRAIN
CORNER TRIM OVER OPENING
DETAIL

4"
DRAIN PIPE TO DIRECT
WATER FROM GUTTER TO
MAIN DRAINAGE (RUN
DRAIN PIPE IN SIDE TRIM) SEE 8-p FOR MIN WIDTH

LINE OF SIDE TRIM


(TRIM WIDTH CAN
MATCH WITH WITH
GUTTER WIDTH)

3D VIEW FOR TYPICAL DETAILS SECTION DETAIL / GUTTER OVER OPENING


1 SCALE NTS (FILE # 7-p-1) 4 SCALE 1" - 1'-0" (FILE # 7-p-4)
DRAWING TITLE:

GSKY GREEN WALL PANELS GUTTER DRAIN


HEIGHT: LESS THAN 16 PANELS
MIN 12"
HEIGHT: BETWEEN 16 AND 24 PANELS
NOT ADEQUATE
HEIGHT: MORE THAN 24 PANELS
NOT ADEQUATE
DRAIN DETAILS / INTERIOR OR EXTERIOR TRENCH DRAIN MIN 12" MIN 24" MIN 36" (ASK GSKY)
GUTTER DRAIN TRENCH DRAIN GROUND DRAIN MIN 12" MIN 24" MIN 36" (ASK GSKY)

GRAVEL DRAIN CURB DRAIN CURB DRAIN MIN 12" MIN 24" MIN 36" (ASK GSKY)

DRAWING #
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST
*DRAIN AREA SHOULD EXTEND MIN 1/2 DRAIN WIDTH FROM EACH SIDES OF GREEN WALL
VANCOUVER, BC V6B 2V2
8-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com
*MIN WIDTH MAY CHANGE DEPENDING ON PLANT SELECTION
*WATERPROOFING IN TRENCH AND CURB DRAIN ARE REQUIRED
*GREEN WALL BELOW MUST TO BE CLEAR FOR MAINTENANCE LIFT ACCESS

METAL GRATING COVER

STAINLESS OR STRIP OF MEMBRANE


TRENCH DRAIN AREA
ALUMINUM GUTTER OVER GUTTER
DRAIN

WATERPROOFING
SLOPED FLOOR FINISH
4"

2" DRAIN PIPE WITH


SCREEN COVER
SEE TABLE FOR MIN WIDTH

2" DRAIN PIPE WITH


SCREEN COVER
SEE TABLE FOR MIN WIDTH

SECTION DETAIL / GUTTER DRAIN SECTION DETAIL / TRENCH DRAIN


1 SCALE 1" - 1'-0" (FILE # 8-p-1) 2 SCALE 1" - 1'-0" (FILE # 8-p-2)

DRAIN AREA WITH


GRAVEL

FINISHED CURB
DRAIN AREA WITH AROUND DRAIN AREA
GRAVEL
WATERPROOFING

HARD SURFACE FOR


MAINTENANCE WITH LIFT WATERPROOFING
MIN 6"

MIN 6"
PERFORATED
DRAINAGE PIPE

SEE TABLE FOR MIN WIDTH

2" DRAIN PIPE WITH


SCREEN COVER
SEE TABLE FOR MIN WIDTH

SECTION DETAIL / GRAVEL DRAIN SECTION DETAIL / CURB DRAIN


3 SCALE 1" - 1'-0" (FILE # 8-p-3) 4 SCALE 1" - 1'-0" (FILE # 8-p-4)
DRAWING TITLE:

GSKY GREEN WALL PANELS


IRRIGATION CONTROL UNIT (ICU) DESIGNS
ICU-1000 PLUMBING REQUIREMENTS
ICU-600 ELECTRICAL REQUIREMENTS
DRAWING #
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2
9-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com

ICU-1000 ICU-600
IRRIGATION CONTROL UNIT FOR:
IRRIGATION CONTROL UNIT FOR: *GREEN WALLS SMALLER THAN 1080 SQFT (INTERIOR OR EXTERIOR)
*GREEN WALLS LARGER THAN 1080SQFT (INTERIOR OR EXTERIOR) *EXTERIOR WALLS IN USDA PLANT ZONE 9 OR HIGHER (NON-FREEZING
*EXTERIOR GREEN WALLS IN FREEZING CLIMATES USDA PLANT CLIMATES)
ZONE 8 OR BELOW (USDA PLANT ZONE 8 = MAX 20F OR -6.7C)

1" IRRIGATION MAIN LINE


CONTROLLER / TIMER CONTROLLER / TIMER INLET (SIZE MAY VARY)
1'-3" 2' 1'-3" 3'
PRESSURE REGULATION
VALVE
PRESSURE REGULATION
MASTER VALVE
VALVE

1" IRRIGATION MAIN LINE


INLET (SIZE MAY VARY)
1'-1"

1'-1"
HARD WIRE CONNECTION HARD WIRE CONNECTION
120 VAC / 2 AMP IN CONDUIT 120 VAC / 2 AMP IN CONDUIT
BY ELECTRICIAN BY ELECTRICIAN
DEDICATED TELEPHONE LINE DEDICATED TELEPHONE LINE
WITH RJ 11 CONNECTION BY WITH RJ 11 CONNECTION BY
ELECTRICIAN ELECTRICIAN FLOW SENSOR
REQUIRES MIN. 1'
FERTILIZER INJECTOR STRAIGHT PIPE BEFORE
CONDUIT WITH 16 GA SOLID AND AFTER THE SENSOR
COPPER MULTI-STRAND
CABLE BY OTHERS
(# OF WIRES DETERMINED BY
# OF IRRIGATION ZONES AND
4'

4'
SENSORS ON THE WALL)

1" CONDUIT BY G-SKY 1" CONDUIT BY G-SKY

FERTILIZER INJECTOR

DEDICATED IRRIGATION ZONE


SUPPLY LINES FROM ICU TO
GREEN WALL BY OTHERS
FERTILIZER TANK FERTILIZER TANK
1" FIPT STUB-OUTS ARE REQUIRED

FLOW SENSOR
REQUIRES MIN. 1' STRAIGHT DEDICATED IRRIGATION ZONE
PIPE BEFORE AND AFTER SUPPLY LINES FROM ICU TO
THE SENSOR GREEN WALL BY OTHERS
3/4" FIPT STUB-OUTS ARE
GRAVITY DRAIN VALVE FOR REQUIRED; 1" SUPPLY LINE
AUTOMATED WINTERIZATION MAY BE USED TO KEEP FLOW
TO STUB-OUT

*REQUIREMENTS: *REQUIREMENTS:
*ICU - 48"h x 24"w x 36"d (INCLUDING DOOR SWING) *ICU - 48"h x 36"w x 48"d (INCLUDING DOOR SWING)
*CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING) *CONTROLLER - 13"h x 15"w x 20"d (INCLUDING DOOR SWING)
*EASY ACCESS FOR MAINTENANCE *EASY ACCESS FOR MAINTENANCE
*ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP *ADEQUATE PRESSURE TO GET MIN PSI AT BOTTOM OF GREEN WALL (TYP
65 PSI, UP TO 50 FT HEIGHT WALL) 65 PSI, UP TO 50 FT HEIGHT WALL)
INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER) INSTALL BOOSTER PUMP IF REQUIRED (BY PLUMBER)
*120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN) *120V / 2 AMP POWER (HARD WIRE) (BY ELECTRICIAN)
*DEDICATED TELEPHONE LINE RJ 11 (FOR OTHERS) *DEDICATED TELEPHONE LINE RJ 11 (BY OTHERS)
*GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN) *GROUNDING CONNECTION IF REQUIRED (BY ELECTRICIAN)
*1 1/4" CONDUIT BETWEEN ACC AND EACH TRIM SPACES FOR ZONE VALVE *BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER)
CONTROL WIRES AND FREEZING SENSOR (BY ELECTRICIAN) *CAN BE EXPANDED MAX 6 ZONES TO ACCOMMODATE IF THERE IS NO
*BACK-FLOW PREVENTOR AS REQUIRED (BY PLUMBER) SPACE FOR VALVES AT THE GREEN WALL(S)
*GREEN WALL MUST BE DESIGNED TO HAVE SPACE FOR ZONE VALVES TO *NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN
RUN ALONG THE SIDE OF THE GREEN WALL WITHIN THE SIDE TRIM (MIN 7" *CAN BE LOCATED OUTDOORS WITH ADDITIONAL ENCLOSURE
WIDE TRIM) OR ABOVE THE WALL IN THE TOP TRIM (MIN 8" HIGH TRIM) *CAN BE CUSTOM DESIGNED TO ACCOMMODATE FREEZING CLIMATES
*NON-FREEZING INDOOR SPACE WITH FLOOR DRAIN

ICU-1000 / ZONE VALVES AT GREEN WAL ICU-600 / ZONE VALVES AT ICU


1 SCALE 3/4" - 1'-0" (FILE # 9-p-1) 2 SCALE 3/4" - 1'-0" (FILE # 9-p-2)
DRAWING TITLE:

GSKY GREEN WALL PANELS


IRRIGATION LAYOUT 1 MAX. 36 PANELS IN EACH CONTINUOUS ROW
IRRIGATION LAYOUT FOR ICU-1000 STUB-OUT DETAIL MAX. 5 PANELS HEIGHT IN ONE ZONE
IRRIGATION LAYOUT FOR ICU-600 ZONE VALVE DETAIL MAIN IRRIGATION SUPPLY LINE CAN BE COPPER, PEX OR PVC TO MEET
DRAWING # LOCAL CODE (BY PLUMBER)
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2 STUB-OUT SHOULD BE INSTALLED WITH FEMALE PIPE THREAD FITTINGS
10-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com

MAX 36 PANELS IN SINGLE ROW

MAX 5 PANELS HEIGHT IN SINGLE ZONE

S
CAN BE IN SAME ZONE IF 3 OUT
OF 5 ROWS IN SINGLE ZONE

MAX 2"
ARE CONTIUOUS

3/4" FIPT IRRIGATION


S STU-OUT BY OTHERS
SEE DRAWING #1 FOR
STUB-OUT LOCATIONS

IF MORE THAN 3 OUT 5 ROWS


3/4" STUB-OUT WITH FIPT ARE TERMINATED BY OPENING, 1 1/2"
CONNECTION (MAIN LINE REQUIRE ANOTHER STUB-OUT
MAY BE 1" TO KEEP FLOW)
S S 4"

IRRIGATION LAYOUT FOR ICU-600 / ZONE VALVES AT ICU IRRIGATION STUB-OUT DETAIL FOR ICU-600
1 SCALE NTS (FILE # 10-p-1) 2 SCALE 1-1/2" = 1'-0" (FILE # 10-p-2)

1" IRRIGATION
SINGLE IRRIGATION STUB-OUT LOCATE ZONE VALVES WITH IN INSTALL FREEZING AND REV
SUPPLY LINE FROM
AND CONDUIT FOR ICU-1000; SEE TOP TRIM SPACE; MIN 8" TOP TRIM FREEZING SENSOR FOR
STUB-OUT
9-p FOR REQUIREMENTS SPACE IS REQUIRED FREEZING REGION

MAX 36 PANELS IN SINGLE ROW


GSKY TOP TRIM

6 1/2"
C
Z Z S Z Z F
CONTROL WIRES
MAX 5 PANELS HEIGHT IN SINGLE ZONE

(FREE WIRED OR IN
CONDUIT)
D D

8"
ZONE VALVES

D D
LOCATE DRAIN VALVES AT
BOTTOM OF EACH ZONE FOR
FREEZING REGION

IRRIGATION LAYOUT FOR ICU-1000 / ZONE VALVES IN TOP TRIM ZONE VALVE DETAIL FOR ICU-1000 IN TOP TRIM
3 4 SCALE 1-1/2" = 1'-0" (FILE # 10-p-4)
SCALE NTS (FILE # 10-p-3)
DRAWING TITLE:

GSKY GREEN WALL PANELS


IRRIGATION LAYOUT 2 MAX. 36 PANELS IN EACH CONTINUOUS ROW
IRRIGATION LAYOUT FOR ICU-1000 - MAX. 5 PANELS HEIGHT IN ONE ZONE
ZONE VALVE DETAIL - MAIN IRRIGATION SUPPLY LINE CAN BE COPPER, PEX OR PVC TO MEET
DRAWING # LOCAL CODE (BY PLUMBER)
DATE: AUG 18, 2010 SCALE: AS NOTED #704 - 318 HOMER ST
VANCOUVER, BC V6B 2V2 STUB-OUT SHOULD BE INSTALLED WITH FEMALE PIPE THREAD FITTINGS
11-p REV DATE: N/A PAPER SIZE: 11 x 17 604-708-0611 ph 604-357-1315 fax
www.gsky.com

MAX 36 PANELS IN SINGLE ROW

INSTALL FREEZING AND REV


FREEZING SENSOR FOR
FREEZING REGION

D 1" IRRIGATION

6 1/2"
SUPPLY LINE FROM
LOCATE ZONE VALVES WITH IN STUB-OUT
SIDE TRIM SPACE; MIN 6" SIDE
CONTROL WIRES
TRIM SPACE IS REQUIRED
(FREE WIRED OR IN
Z CONDUIT)
6"
D ZONE VALVES
7"
GSKY TOP TRIM
MAX 5 PANELS HEIGHT IN SINGLE ZONE

MAX 50 PANELS HEIGHT


Z

D
ZONE VALVE DETAIL FOR ICU-1000 IN TOP TRIM
2 SCALE 1-1/2" = 1'-0" (FILE # 11-p-2)

D
LOCATE DRAIN VALVES AT
BOTTOM OF EACH ZONE FOR
FREEZING REGION

Z
D
SINGLE IRRIGATION STUB-OUT
Z
AND CONDUIT FOR ICU-1000; SEE
8-p FOR REQUIREMENTS D
S C

IRRIGATION LAYOUT FOR ICU-1000 / ZONE VALVES IN SIDE TRIM


1 SCALE NTS (FILE # 11-p-1)

Anda mungkin juga menyukai