M A C R O - T E C H S E R I E S

MA-2402

Features • Enhanced PIP2™ (Programmable Input Pro-

M
acro-Tech® Series amplifiers deliver
superior sonic accuracy and enor- cessor) connector accepts new accessory
• Crown’s Grounded Bridge™ design delivers
mous amounts of power from a low- large voltage swings without using easily modules that tailor the amplifier to suit spe-
profile design, and are perfect for touring and stressed output-transistor configurations like cific applications.
fixed installations. conventional amplifiers. The results are • Balanced XLR and 1/4-inch(6.35-mm) phone
The Crown Macro-Tech 02 Series amps are lower distortion and superior reliability. jack inputs for each channel on the standard
enhanced versions of the Macro-Tech line. • Patented ODEP® (Output Device Emulation PIP2-FXQ module.
They offer the same features and perfor- Protection) circuitry compensates for over- • Full protection from shorted, open and mis-
mance of the original Macro-Techs while heating and overload to keep the amplifier matched loads; general overheating; DC;
delivering key added benefits that continue to working when others would fail. high-frequency overloads; and full protection
expand the versatility of this distinct product from internal fault are provided by our latest
• IOC® (Input/Output Comparator) circuitry im-
line. protection scheme: “Quad-Mute.”
mediately alerts of any distortion exceeding
When it comes to manufacturing amplifiers, 0.05%, providing dynamic proof of distor- • Three Year No-Fault Full Warranty completely
there are no shortcuts to quality. Crown’s tion-free performance. protects your investment and guarantees its
Macro-Techs have proved themselves time specifications.
and time again in some of the most demand-
ing applications in the world.
20:1 ±3% or 26 dB ±0.25 dB at 2.2- volt Level: A front-panel 31-detent rotary control
For more details about the Crown Macro-
sensitivity at the maximum level setting. for each channel used to control the output
Tech Series, contact the Crown Technical
Support Group at 800-342-6939 or 219-294- level.
Required AC Mains: 50/60 Hz; 100-, 120-,
8200. Also, visit the Crown Audio website at 220- and 240 -VAC (±10%) units are Stereo/Mono: A three-position back-panel
www.crownaudio.com. available. All draw 100 watts or less at idle. switch used to select Stereo, Bridge-Mono or
Specifications Current, voltage and frequency requirements Parallel-Mono mode.
Note: Specifications relate to120-volt, 60-Hz units in Stereo are provided on the unit’s back panel. Sensitivity: A three-position switch inside the
mode with 8-ohm loads and an input sensitivity of 26-dB AC Line Connector: NEMA 5-20P (20A). PIP™ compartment used to select the input
gain at 1 kHz rated power unless otherwise specified.
sensitivity for both channels: 0.775 volts or
Specifications for units supplied outside the U.S.A. may Performance
vary slightly at different AC voltages and frequencies. 1.4 volts for standard 1-kHz power, or a 26 dB
Frequency Response: ±0.1 dB from 20 Hz to voltage gain.
Power 20 kHz at 1 watt.
Output Power: Reset: A back-panel push button for each
Phase Response: ±10 degrees from 10 Hz to channel used to reset the circuit breaker that
20 kHz at 1 watt. protects each power supply.
*1 kHz **20 Hz–20 kHz
MA-2402 Power Power Signal-to-Noise Ratio, A-weighted:
Indicators
2-ohm Dual (per ch.) 1,050W 850W Better than 105 dB below rated full band- Enable: An amber front-panel indicator that
width power. shows the on/off status of the low-voltage
4-ohm Dual (per ch.) 800W 750W
20 Hz to 20 kHz: power supply.
8-ohm Dual (per ch.) 520W 505W
Better than 100 dB below full bandwidth Signal/IOC: A green front-panel indicator for
4-ohm Bridge-Mono 2,070W 1,670W power. each channel that flashes to show amplifier
8-ohm Bridge-Mono 1,585W 1,485W Total Harmonic Distortion (THD): full output. If a channel’s output waveform differs
bandwidth power, Less than 0.05% from from its input by 0.05% or more, the indicator
*1 kHz Power: refers to maximum average power in watts flashes brightly to show distortion. This
at 1 kHz with 0.1% THD. 20 Hz to 1 kHz increasing linearly to 0.1% at
**20 Hz–20 kHz Power: refers to maximum average power 20 kHz. function provides proof of distortion-free
in watts from 20 Hz to 20 kHz with 0.1% THD. performance. In Parallel-Mono mode, the
Intermodulation Distortion (IMD): (60 Hz Channel 2 light stays on.
and 7 kHz at 4:1) Less than 0.05% from 163
Load Impedance: Safe with all types of milliwatts to full bandwidth power. ODEP: An amber front-panel indicator for
loads. Rated for 2 to 16 ohms in Stereo, 4 to each channel that shows thermal-dynamic
Damping Factor: Greater than 1,000 from 10 energy reserve. Normally, each ODEP
16 ohms in Bridge-Mono and 1 to 4 ohms in Hz to 400 Hz.
Parallel-Mono mode. indicator is lit to show available reserve
Slew Rate: (Slew rates are limited to useful energy. In the rare event that a channel has
Voltage Gain to 1-kHz, 8-ohm rated output: levels for ultrasonic/RF protection.) Greater no reserve, its indicator will dim in proportion
54:1 ±12% or 35 dB ±0.5 dB at 0.775-volt than 13 volts per microsecond. to ODEP limiting. An ODEP indicator may also
sensitivity; Controls turn off under other conditions.
30:1 ±12% or 30 dB ±0.5 dB at 1.4-volt Enable: A front-panel push button used to
sensitivity; turn the amplifier on and off.
MA-2402

Input/Output Parallel-Mono: Unbalanced, single-channel. Turn On: Four-second delay with no danger-
Input Connector: Two balanced ¼-inch (6.35- Channel 1 controls are active; Channel 2 ous transients. Delay time can be changed
mm) phone jacks on the back panel and two controls are bypassed. (contact Crown’s Technical Support Group).
balanced three-pin female XLR connectors on Protection Accessories
the factory-installed PIP2-FXQ. Macro-Tech amplifiers are protected against Crown PIP and PIP2 modules including IQ-
Input Impedance: Nominally 20 k ohms, shorted, open or mismatched loads; PIP modules.
balanced. Nominally 10 k ohms, unbalanced. overloaded power supplies; excessive Construction
Maximum Input Level: 9 Vrms. temperature; chain destruction phenomena;
Steel chassis with durable black finish,
input overload damage; and high-frequency
Input Sensitivity: 0.775 volts for standard 1 aluminum front panel with Lexan overlay, and
blowups. They also protect loudspeakers
kHz power, 1.4 volts for standard 1 kHz specially designed flow-through ventilation
from input/output DC and turn-on/turn-off
power, or a 26 dB voltage gain. from front to side panels.
transients.
Output Connectors: Two sets of color-coded Cooling: Internal heat sinks with forced-air
If unreasonable operating conditions occur,
5-way binding posts (for banana plugs, spade cooling for rapid, uniform heat dissipation.
the patented ODEP circuitry will proportionally
lugs or bare wire). limit the drive level to protect the output Dimensions: EIA Standard 19-inch (48.3-cm)
Output Impedance: Less than 10 milliohms in transistor stages, particularly in the case of rack mount width (EIA RS-310-B), 3.5-inch
series with less than 2 microhenries. elevated temperature. Transformer overheat- (8.9-cm) height, 16-inch (40.6-cm) depth
DC Output Offset: (Shorted input) ±10 ing will result in a temporary shutdown of the behind the mounting surface and 2.5-inch
millivolts. affected channel; when it has cooled to a safe (6.3- cm) protrusion in front of the mounting
temperature, the transformer will automati- surface.
Output Signal cally reset itself. Controlled slew-rate voltage Approximate Weight: Center of gravity is
Stereo: Unbalanced, two-channel. amplifiers prevent RF burnouts. And input 6 inches (15.2 cm) behind front mounting
Bridge-Mono: Balanced, single-channel. overload protection is provided by current- surface. 51 pounds, 12 ounces (23.5 kg) net;
Channel 1 controls are active; Channel 2 limiting resistance at the input. 65 pounds (29.5 kg) shipping weight.
should not be used.

Crown’s Three-Year, No-Fault, Full Warranty


Crown offers a Three-Year, No-Fault, Full Warranty for every new Crown amplifier—an unsur-
passed industry standard. With this unprecedented No-Fault protection, your new Crown Crown International, Inc.
amplifier is warranted to meet or exceed original specifications for the first three years of P.O. Box 1000
ownership. During this time, if your amplifier fails, or does not perform to original specifica- Elkhart, IN 46515-1000
tions, it will be repaired or replaced at our expense. About the only things not covered by this TEL: 219-294-8200
warranty are those losses normally covered by insurance and those caused by intentional FAX: 219-294-8FAX
abuse. And the coverage is transferable, should you sell your amplifier. www.crownaudio.com

See your authorized Crown dealer for full warranty disclosure and details. For customers
Crown, Macro-Tech, IOC and ODEP are registered
outside of the USA, please contact your authorized Crown distributor for warranty information trademarks, and Ground Bridge, PIP and PIP2 are
or call 219-294-8200. trademarks of Crown International, Inc. Printed in U.S.A.
©
2000 Crown International, Inc.

10/00 128361-2