Facts At Your Fingertips

Insulating Heat-Transfer-Fluid Piping


Department Editor: Scott Jenkins

TABLE 1. KEY PROPERTIES OF COMMON PIPING INSULATION TYPES

H
eat-transfer-fluid (HTF) system
piping is insulated to reduce Insulation type Temperature use range Absorbent? Price
heat loss and prevent worker Fiberglass 0 to 1,000°F (–18 to 538°C) Yes Low
contact with hot surfaces. Insulated Mineral wool 0 to 1,400°F (–18 to 760°C) Yes Low
piping minimizes the effects of chang- Calcium silicate 80 to 1200°F (27 to 650°C) Yes Medium
Cellular glass –450 to 800°F (–268 to 427°C) No Medium
es in ambient temperature to help en-
sure precise control of process tem- most probable explanation is that a fiberglass and so on, may be used.
perature. Proper design of the HTF slow exothermic oxidation reaction On vertical runs of lines of pipe
system and its insulation is required between hydrocarbon-type heating where occasional sources of leaks
to reduce the risk of fire as a result of fluids and the air inside the voids of can develop at flanges and valves,
fluid leakage into insulation. the insulation starts at about 500°F. install protective, tight-fitting caps
Such a reaction is believed to occur below flanges and valves to divert
Types of insulation for the following reasons: any fluid leakage to the outside of
The main insulation materials used t A large heating surface area the insulation.
for HTF system piping are fiberglass, exists within the insulation Install valve stems horizontally to
mineral wool, calcium silicate and t Formation of low-flash-point help avoid stem leakage from enter-
cellular glass. Table 1 lists some im- oxidation products, resulting ing the insulation.
portant properties to consider when from exposure to air On those sections of lines where
choosing insulation. t Temperatures can rise within greater numbers of control valves
Fiberglass and mineral wool are the saturated insulation mass and instrument fittings present high-
fibrous materials produced in simi- due to poor heat dissipation er leakage risk, install cellular glass
lar processes. Thermal conductiv- conditions insulation or metal-shielded insula-
ity is similarly low for both materials. Tests indicate that fiberglass, min- tion to minimize or eliminate any fluid
Calcium silicate insulation is formed eral wool and calcium silicate insula- saturation of the insulation system.
by drying a calcium silicate slurry tions are more subject to this prob- Consult your company’s insulation
in a mold, yielding a material with a lem, since they can absorb large supplier and insurance company for
slightly higher thermal conductiv- amounts of leaking fluid with greater additional suggestions on reducing
ity than fiberglass or mineral wool. surface area of liquid-air contact. fire hazards. Q
These three materials have open, air- Cellular glass insulation resists
filled channels, which can wick leak- saturation by heat transfer fluid and, References
ing fluid into the insulation. therefore, may be a safer insulation to 1. “Systems Design Data,” Publication No. 7239193C,
Cellular glass insulation is formed use. Cellular glass normally is more Solutia Inc., subsidiary of Eastman Chemical Co.,
by heating a glass powder mixture, costly for most applications because September 2002.
which melts and expands, leaving of its higher installation cost and its 2. “Liquid Phase Design Guide,” Publication No. TF-04,
5/14, Eastman Chemical Co.
tiny, sealed glass cells throughout the tendency to crack when thermally
3. Controls Southeast Inc., “Insulation,” from www.csiheat.
material. It is impermeable to leaking shocked. Cellular glass is suggested com/csi_university/insulation.aspx, accessed January
fluid and has a thermal conductivity for use around flanges and other ar- 2016.
similar to calcium silicate. eas where leaks are likely to occur,
while lower-cost insulation materials Author
Insulation design may be used for pipe racks and all- The content for this edition of “Facts at Your Fingertips” was
supplied by the Eastman technical support team. If you have
Insulation should be installed to cover welded runs of piping. additional questions or comments, please email Eastman at:
all piping and other exposed surfaces team.therminol@eastman.com.
of the HTF system where heat loss Tips to reduce risk of fire Disclaimer: Although the information and recommenda-
can occur. Free online calculators can Install and maintain a leak-free piping tions set forth herein are presented in good faith, Eastman
be used to determine required insula- system when combustible heat-trans- Chemical Co. and its subsidiaries make no representations
or warranties as to the completeness or accuracy thereof.
tion thickness for most processes. fer fluids are being used. Reduce the No representations or warranties, either express or implied,
number of flanges and incorporate or merchantability, fitness for a particular purpose or of
Fire safety adequate flexibility of piping. Use sug- any other nature are made hereunder, and nothing herein
waives any of the seller’s conditions of sale. Eastman and
Fires have occurred in insulation ma- gested piping specifications. If a leak Therminol are trademarks of the Eastman Chemical Co. or
terials that have been soaked with or- develops, remove the insulation and its subsidiaries.
ganic heating fluids at apparent tem- contain and control the HTF until the
peratures of 500 to 600°F, which is leak can be repaired.
Facts At Your Fingertips
well below the autoignition tempera- On horizontal runs of pipe with Sponsored by:
ture of most commercial HTFs. While welded joints and proper flange fit-
the exact mechanism by which such tings, the standard high-temperature
fires occur is not fully understood, the insulation, such as calcium silicate or
38 CHEMICAL ENGINEERING WWW.CHEMENGONLINE.COM MAY 2016