VRF system
and
Chiller system
1
1. Outline
VRF systems (Variable Refrigerant Flow)
Application
• Office
• Hotel, Condominium
• Hospital
• School (University)
-for Individual room control building
2
<DC Twin inverter compressor>
- All inverter
compressor can be Competitor KX4
back-up inverter D
operation
Back-up
continues. operation
Back-up
operation
= ON /
compressor = inverter
OFF
control
failed control
compressor
- To maximize life only
failed
span, starting order
of compressors are
inverter
switched. inverter Fixed
speed
3
<Quietness>
KX4 is quiet…
noise level
68
66
64
62
60
58
Much quieter with “Silent Mode” MHI(KX4)
A
B
56 B'
C
54
22.4 28 33.5 40 45 50.4 56 61.5 68 73.5 80 85 90 96 101 107 113 118 124 130 136
4
Indoor Units
KX4 offers a wide range of indoor units (14 types/77models)
MHI 14 77
Competitor D 11 65
5
Control Systems (with SUPERLINK)
Connectable Electric
Classification Type Model I/D units power
(Maximum) calculation
Individual controller Wired RC-E1R 1 −
Wireless RCN-TC-W-ER etc. 1 −
SC-SLA2A-ER 48 −
SC-SLB3-ER 144 ○
SC-WGW-BR 96 ○
LONworks SC-LGW-AR 96 −
6
Chiller systems
Outline & Feature System
Application
・ Factory
・ Gymnasium
・ Office, Restaurant
-for large room and space
7
Comparison
◎:better ○:sufficient △: can be improved
Running cost ◎ ○
Facility space ◎ △
Temperature/humidity control ◎ ○
Maintainability ○ △
8
VRF VS CHILLER COMPARISON
9
10
11
5
3. Others
<Energy Consumption> Heat source equipment
-Typical Office Building [291] (16.0)
Heat source
Elevator etc., [364] (20.0)
Sanitation &
Others
[373] (20.5) Heat source auxiliary
equipment
[73] (4.0)
Energy
consumption Exhaust fan
of building [198] (10.9)
[1817] (100)
Medium transportation
for air-conditioning
Lighting [494] (27.2)
[586](32.3)
Air-conditioning fan
[173] (9.5) Air-conditioning
[858](47.2)
Pump for air-conditioning
[123] (6.8)
[ ] : Yearly energy consumption per square [MJ/m2・yr], ( ) : Percentage makeup against total energy consumption
(%)
12
<Future Air-Conditioning Systems>
Comfort
・ Thermal comfort
differs for each
Flexibility individual human beings Energy saving
・ Change of ・ Various work ・ Heat recovery
partition time bands ・ Reduction of
・ Change of transportation power
layout ・ Start/stop control
・ Variation of heat Requirements of Individual unit
generated by OA for air
equipment conditioning
Maintainability and Safety and reliability
controllability in the building
・ Protection
・ Easy from now on against earthquake,
maintainability of
fire and water leakage
equipment
・ Easy Operation
method 13
The trend of Air-conditioner
for sophisticated buildings
the shift is to
VRF system!!
14