Our promise to the planet is absolute. Our products are at the forefront
of low energy consumption and we continuously innovate to reduce the
environmental impact of HVACR solutions further.
We lead where others follow. We will continue our global leadership in HVACR
solutions as our specialist expertise in all market sectors combined with 90
years’ experience enable us to deliver added value in long-lasting relationships
based on trust, respect and credibility.
Table of contents
Ben 18
NEW ies
W-s
er Outdoor units 20
Indoor units 21
Specifications 39
03
Over 30 years of
VRV History
›
systems
2003
Introduce VRVII-- the first R-410A
VRF system 2005
1991 Available in cooling, heat pump and Extends VRVII inverter
range with water cooled
Introduce VRV heat heat recovery
recovery › VRV-WIII
› Simultaneous cooling and 1994 refrigerant circuit › Available in heat pump and
heat recovery
heating Awarded ISO9001 certification
04
2009 2011 2015
Extends VRVIII range Launch total solution concept Launch of VRV IV S-series
with water cooled VRV-WIII › Integrate hot water production and › Most compact unit in the market
› Geothermal version available Biddle air curtains into VRV system › Widest range in the market
› › Connectable to Daikin Emura and
Nexura
›
›
06-2007 2009 2008 2010 2009 2011 2010 2012 2011 2015 2012 2015
2006-2007
Launch the extensively
re-engineered VRVIII 2010 2012-2014 2015
› Available in cooling, heat Launch of replacement VRV Setting new standards with the Launch of VRV IV i-series
pump and heat recovery (VRVIII-Q) launch of VRV IV › The invisible VRV
› Automatic charging and › Upgrade to replace older VRV units › › Unique product concept
testing ›
Continuous heating on heat pumps VRV IV High Ambient
› › Available in heat pump, heat
recovery, water-cooled and
replacement series
05
VRV IV standard &
technologies
Our new VRV IV systems set pioneering
standards in all-round climate comfort
performance. Total design simpli
rapid installation, full exibility as well as
absolu ciency and comfort. Find out
about all these revolutionary changes at
www.daikinmea.com
06
VRV IV =
s d r a d n
Variable Refrigerant Temperature
Refrigerant-cooled PCB
07
Variable refrigerant
temperature
Customise your VRV for The colder it gets, the lower the load on the building and the lower the capacity need
in cooling mode
Capacity & Load
Thanks to its revolutionary variable refrigerant Adjust capacity by
Te control to meet
temperatue technology (VRT), VRV IV continuously the load (avoid over
capacity
System
capacity and ON/OFF
adjusts both the inverter compressor speed and the operation)
a t s y r a n
refrigerant temperature, providing the necessary
capacity to meet the building load with the highest
seasonal efficiency at all times!
o i t u l o v e r 25 30 38 46 Outdoor temperature 3
› Seasonal e ciency increased by 28%
› t weather compensating control on the
The lower the capacity need the higher the refrigerant temperature can be
market
› Customer comfort is assured thanks to higher
outblow temperatures (preventing cold
cooling (evaporating temper-
draughts)
Refrigerant temperature in
Variable Te
VRF standard
Capacity is controlled only with the variance of the 25 30 38 46 Outdoor temperature
inverter compressor
Daikin VRV IV
Variable Refrigerant Temperature control for energy
saving in partial load condition. A higher refrigerant temperature results in a higher
The capacity is controlled by the inverter compressor seasonal e ciency and higher comfort
AND variation of the evaporating (Te) and condens-
ing (Tc) temperature of the refrigerant in order to
achieve the highest seasonal efficiency.
Efficiency
E ciency up
25 30 38 46 Outdoor temperature
Variable Temp.
Fixed Temp.
08
Different modes to
maximise efficiency
and comfort
For maximum energy efficiency and customer
satisfaction, the outdoor unit needs to adapt
the evaporating/condensing temperature at the
optimum point for the application.
How to set
the different modes?
p at e n
Set up the main operation mode
of the system
Define how the system reacts
to changing loads
ts
St St
Quick Same as above but slower response than the powerful mode.
The perfect balance: This mode would be suitable for most o ce applications
Achieves top efficiency throughout the year, Mild * and it is the factory set mode.
reacts quickly on the hottest days The perfect balance: Slower reaction speed with top e ciency
High sensible Gives customer choice for fixing coil temperature which avoids cold draughts.
(User selection) Powerful A quick reaction speed to changing load has priority, with temporarily colder
outblow as a result.
This is how most other VRF systems work and can be used for all general type of
Basic No submodes applications. Suitable for computer rooms.
Current VRF standard
Suitable for low ceiling rooms.
* Factory setting
09
Software for simplified
commissioning,
configuration and
customisation
10
VRV
configurator software
Graphical interface
Manage systems over multiple sites in exactly
the same way
Retrieve initial settings
-digit egment
display
Connect directly
to your laptop
Pre configured
settings from office
User-friendly interface
instead of push buttons
11
Unique VRV IV
core technologies
Newly developed
patents
compressor
Full inverter High e ciency J-t ole motor
Refrigerant-cooled PCB
› Reliable cooling because it is not influenced by
ambient air temperature
› Smaller switchbox for smoother air flow
through the heat exchanger increasing
heat exchange efficiency by 5%
patents
patents
12
UNIQUE
Waste
compressor
operation
Target
Predictive Control
Function (PCF) General VRF:
Double time against VRV IV
The large number of Daikin systems already in operation › result: quick convergence to the target temperature
Half time
and which are monitored by our Intelligent Network and reduction of waste operation of the compressor
against
software put us in the unique position of being able to general
analyse this data and develop the predictive compressor General VRF: Pi control VRF
Compressor works with feedback only for the control
control function.
› result: waste operation and longer time before reaching
target set point
DC fan motor
UNIQUE
Outer rotor DC motor for higher e ciency Conventional motor with inner rotor Daikin outer rotor
°C °C
13
14
Daikin Anti-Corrosion Solutions
for maximum peace of mind
For prolonged lifespan of the condenser coil and other components with Anti-Corrosion Protection coating,
the following recommendations for care and maintenance should be followed:
› Avoid sandy location, i.e. near the shore and windy areas
› Clear all unwanted debris/drilling metal particles on the › In situation where the unit is installed close to coastal area
bottom tray and base leg after installation work to and exposed to strong breeze, it is important to install a
prevent any scratches or cracks onto the anti-corrosion windbreaker or retaining wall to prolong the life span of
protection coating that will cause rust formation the equipment protection coating.
Sandy Location Rooftop with Strong Sea Breeze Enclosed Area and Sea Water Splashing
Coastal sand stuck in between Strong sea breeze blowing directly to Condition
coil can shorten the life of the coil. Sea water splashing directly to the coil causes
protection coating.
15
ECPEN15-206A.indd 4 24/03/15 11:47
Hydrophilic film
Special anti corrosion treatment of the heat exchanger Aluminium
provides 5 to 6 times greater resistance against acid Corrosion-resistant
rain and salt corrosion. Heat exchanger
Acrylic resin
Cycle
› Ventilation
Heating for high quality environments
Cooling › Controls
for maximum operating efficiency
Controls
Ventilation
Fresh Air
16
ECPEN15-206A.indd 5 24/03/15 11:47
One system,
multiple applications for hotels,
offices, retail, home …
Ventilation
› Widest range in DX ventilation – AHU units
17
ECPEN15-206A.indd 8 24/03/15 11:48
What does a
VRV IV installation
mean to you?
See how you can profit from
Daikin’s highly flexible and
efficient product range.
Consultants
Daikin's VRV IV technology maximises flexibility and Technical design support
leads the way in customisation to match individual Ecological design meets and
building requirements in comfort and energy, with exceeds legal requirements
reduced running costs. Maximum flexibility to meet customer requirements
Advanced software tools assist with system design
Complies with ESMA UAE regulations
Complies with MEW-Kuwait regulations
Complies with SASO Saudi regulations
Building owners
VRV IV is the ultimate in customised comfort and Up to 40% energy consumption saving over conventional AC System
intelligent control tailored to your individual needs Single point of contact for the design and
and to maximise energy efficiency. Annual cost maintenance of your climate system
savings up to % (compared to VRV III). Integrated system, combining air conditioning,
ventilation, etc. allows maximum energy efficiency
Multiple systems can be managed in exactly
the same way for the key accounts
Dedicated after-sales service to
ensure fast on-site support
Installers
Daikin VRV IV sets the standard with state-of-the-art
technology and time-saving commissioning and Simplified and time-saving commissioning
servicing. with VRV configurator
Wide range of outdoor units (up to 48HP)
One supplier = one point of contact
Maximum flexibility to meet customer requirements
Customised training to maximise expertise
18
ECPEN15-206A.indd 9 24/03/15 11:48
VRV Outdoor
Out door units can be single units or combined in multiple units as a module
for larger capacity applications
19
ECPEN15-206A.indd 10 24/03/15 11:48
Outdoor units
RXYTQ-T
›
› Covers all thermal needs of a building via a single point of contact: accurate
VRVIV-S
RXYSQ-T
series
RXYTQ-T
(50/60Hz)
RXYSQ-T
50/60Hz-6HP
P
+
(60Hz)
20
ECPEN15-206A.indd 11 24/03/15 11:48
Indoor units
ESP ›
FXSQ-A
Wall FXAQ-PVER1
› Flat, stylish front panel is more easy to clean
mounted › Small capacity unit developted for small of well-insulated rooms
unit › Reduced energy consumption thanks to DC fan motor
› FXAQ-PVE
discharge angles
Ceiling
› ect
suspended ›
unit › Can easily be installed in both new and refurbishment projects
› Can even be mounted in corners or narrow spaces without any problem
FXHQ-A
› Reduced energy consumption thanks to DC fan motor
For perimeter zone air conditioning
Floor standing
Floor
› Can be installed in front of glass walls or free standing as both the front and
standing
unit › Ideal for installation beneath a window
› Requires very little installation space
› Wall mounted installation facilitates cleaning beneath the unit FXLQ-P
NEW Ideal for installation in o ces, hotels and residential applications
Concealed › Discretely concealed in the wall, leaving only the suction and discharge grilles
visible
standing › Can even be installed underneath a window
unit ›
› FXNQ-A
Cooling capacity (kW) 1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0 45.0 56.0
Heating capacity (kW) 1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5 50.0 63.0
21
Ventilation range
overview
Five components of
indoor air quality
Ventilation
Ventilation: ensures the provision of fresh air
Heat recovery: recovers heat and moisture from
Heat recovery Humidi cation
Air processing: heats or cools incoming fresh air
maximising comfort and minimizing the load on
the air conditioning installation
optimises the balance between Air
Filtration
indoor and outdoor humidity processing
Filtration: removes dust, pollution and odours from
the air
/hr )
Ventilation
Heat recovery
Air handling DX total fresh
Air processing
units air package
Filtration
22
Air handling unit applications
VRV IV
condensing unit
(single or multi)
gas
liquid
Capacity:
Up to 269 kW (Nominal Capacity) - by 4x24 HP OU. Expansion Value Sizes: 50 - 63 - 80 - 100 - 125 - 140 - 200 - 250 - 400 -500
23
ECPEN15-206A.indd 12 24/03/15 11:48
Control w: Off the shelf control of air temperature (discharge Control y: Control of refrigerant (Te/Tc) temperature via Daikin
temperature, suction temperature, room temperature) via any control (no DDC controller needed) with 3rd party thermostat
DDC controller using a proportional 0~10V algorithm for capacity (Daikin control for field settings and error indication)
control Control z: Control of air temperature (suction temperature, room
Control x: Precize control of air temperature (discharge temperature) via Daikin control (no DDC controller needed)
temperature, suction temperature, room temperature) requiring a
preprogrammed DDC controller (for special applications) using a
proportional 0~10V algorithm for capacity control
Ts Ts
Te Td Te Td
Daikin AHU Daikin AHU
control box: control box:
DDC EKEQFCBA DDC
Tr Room EKEQFCBA Tr Room
ON / OFF
KRP4A51
Daikin Ts AHU
Ts Te
control box: Te Td Td
EKEQFCBA Daikin AHU
Tr Room control box:
EKEQDCB Room
Tr
BRC1D52 EKEQMCB
BRC1E53A BRC1D52
BRC1E53A
BRC1H81(9)
Ts = Air suction temperature Tr = Room temperature AHU = Air Handling Unit
Td = Air discharge temperature Te = Evaporating temperature DDC = Digital Display Controller
24
BRC1H81(9)
Experience
a new way
of air conditioning control and
commissioning
White
BRC1H81(9)W
26
Advanced settings can be easily done via
your smartphone
• BLE (Bluetooth Low Energy) communication
• Visual interface for intuitive setting of schedules, set point restriction and other advanced settings for
users / technical managers
• Easy and time saving commissioning for installers
27
Individual control systems
BRC1H81(9)W
›
› Flexible setback function ensures room temperature remains within comfortable limits to ensure guest
comfort
Window contact
BRC1H81(9)W
›
› Set temperature auto reset
›
28
Individual control systems
BRC4*/BRC7*
Infrared remote control
Operation buttons: ON / OFF, timer mode start / stop, timer
mode on
BRC1D52
NEW BRC1E53A
Italian, Portugese
Romanian, Slovenian,
Bulgarian
Slovak, Albanian
29
BRC2E52A / BRC3E52A
Window contact
The schedule timer programmes the schedule and operation conditions for each tenant and the control can
easily be reset according to varying requirements.
DCS302C51
›
units) can be controlled
›
separate locations
› zone control
› group control
› malfunction code display
›
›
› expanded timer function
30
DST301B51
Schedule timer
Enabling 64 groups to be programmed.
›
›
›
›
DCS301B51
›
›
› operating status indication (normal operation, alarm)
› centralised control indication
›
DTA113B51
› Rotation function
› Backup operation function.
31
DCS601C51
Detailed & easy monitoring and operation of VRV systems (max. 64 indoor units groups).
Network
third party controller (domotics, BMS, etc.) via http interface Fire alarm
Ethernet
Forced OFF contact input
DIII-NET
Control Systems
› VRV
System layout › Flexible grouping in zones Cost performance › HRV
› › Yearly schedule › Free cooling function › Sky Air
controlled › Fire emergency stop control › Labour saving › Split (via interface adapter)
› Touch panel (full colour LCD › Interlocking control › Easy installation
via icon display) › Increased HRV monitoring › Compact design: limited
and control function installation space
› Automatic cooling / heating › Overall energy saving
change-over
› Heating optimization
› Temperature limit
›
(general, administration
& service)
› Quick selection and full
control
› Simple navigation
32
33
13_Control_Systems.indb 630 27/10/17 15:46
Flexible
›
equipment such as kWh meters, emergency
input, window contact, … Easy follow up of energy consumption
› Modular concept allows your cloud to grow
with your business
›
Pulse input
Digital input
Functions overview
Indoor uit
Local solution Cloud solution
Languages EN, DE, FR, NL, ES, IT, EL, PT,
Depends on local device RU, TR, DA, SV, NO, FI, CS,
HR, HU, PL, RO, SL, BG, SK
Control Systems
For available Daikin Cloud Service options refer to the option list
34
13_Control_Systems.indb 631 27/10/17 15:46
https://www.youtube.com/
DaikinEurope
DCM601A51
Mini BMS
Price competitive mini BMS
Cross-pillar integration of Daikin products
Integration of third party equipment
Web Access
Internet
Extranet
LAN
3G
Max. 7
DCM601A51 ITM plus adaptor line adapters
Di/Pi port
kWh meter
Direct plug & play connection!
Split
BACnet WAGO
Chillers and AHU
Fan coil units
Lighting Fan
I/O module
Pump Sensor
35
13_Control_Systems.indb 632 27/10/17 15:46
User friendliness
Flexibility
Plug & play
NEW › Cross-pillar integration (heating, air conditioning,
applied systems, refrigeration, air handling units)
NEW ›
› I/O for integration of equipment such as lights,
pumps… on WAGO modules
› Modular concept for small to large applications
Split Fan coils Chillers and AHU Refrigeration
›
and combine multiple ITM via the web interface
Functions overview
CLOUD
Intelligent Network
performance monitoring 24/7
and analysis
37
Data server
Performance supervision
Internet
and analysis
24/7
Prediction analysis
Data trend logging
Information to:
› customers
› service company
CLOUD Controller
Performance monitoring
Analysis
Daikin’s unique Intelligent Network Service
aims to prevent the equipment coming to an Be connected with Daikin’s experts, this gives you
unexpected stop or needing emergency repair. a clear overview of operability and use of the air
conditioning system.
› Daikin continuously monitors energy, operation
Fast response, better prepared and comfort data. Thanks to periodic analysis of
the data, Daikin can suggest ways of improving
› If an alarm does occur, the service provider is performance.
immediately alerted and receives all crucial › if there is a problem, Daikin specialists will analyse
information. the operation data history to provide remote
› Early fault indication (predictions) : operation data support.
are 24/7 checked by Intelligent Network prediction
algorithms to act as early as possible, averting
unscheduled breakdowns.
38
RXYTQ-T7YF
Cooling T1 35oC
(1) Capacity Ton 6.4 8.0 9.5 11.4 12.8
(Nominal) Capacity kW 22.4 28.0 33.5 40.0 45.0
Capacity Btu/h 76,450 95,550 114,350 136,500 153,550
EER (Btu/h) / W 12.1 12.8 11.8 11.0 11.0
PI kW 6.33 7.47 9.68 12.4 14.0
(3)
Cooling T3 46 C o Capacity kW 20.2 25.2 28.5 32.0 35.1
Capacity Btu/h 68,950 86,000 97,250 109,200 119,800
EER (Btu/h)/ W 9.28 9.90 9.72 9.45 9.18
PI kW 7.43 8.69 10.0 11.6 13.0
PI out kW 6.57 8.29 8.64 10.17 11.63
(4) Capacity kW
Cooling T2 48oC 16.8 22.4 24.0 25.1 28.4
Capacity Btu/h 57,350 76,450 81,900 85,650 96,950
kW/Ton 1.30 1.30 1.30 1.28 1.29
EER (Btu/h) / W 9.21 9.25 9.21 9.35 9.28
PI kW 6.22 8.29 8.89 9.16 10.4
PI out kW 5.93 7.80 8.43 8.65 9.87
Heating (nominal)
(5) Capacity kW 22.4 28.0 33.5 40.0 45.0
Capacity Btu/h 76,450 95,550 114,350 136,500 153,550
COP (Btu/h) / W 13.2 12.7 12.0 12.2 11.8
PI kW 5.20 6.67 8.54 9.98 11.7
Sound level (nominal) Sound power dBA 78 81 81 86 86
Sound pressure dBA 58 61 61 64 64
Dimensions HxWxD 1680x930x765 1680 x 1240 x 765
Operation range cooling Outdoor -5 ~ 55˚CDB (6)
Indoor 14 ~ 25˚CWB
Operation range Heating Outdoor -20 ~ 15,5˚CWB
Indoor 15 ~ 27˚CDB
Connection Ratio VRV indoor unit only 50 ~ 130%
VRV indoor + AHU Total: 50 -110% (VRV Indoor : 50-110%)
AHU only 75 ~ 110%
Refrigerant Type R-410A
Pipe Connection Liquid Ø 9.52 mm Ø 9.52 mm Ø 12.7 mm
Gas Ø 19.01 mm Ø 22.2 mm Ø 28.6 mm
Total Piping Length System Actual m 1000
Max. connectable indoor units 64
Wiring Length Total Wiring Length : 2000 m
Compressors 1 1 1 2 2
Power Supply 3 Phase/ 380-415V/ 50Hz
3 Phase/400 V / 60Hz
(1) indoor temperature: 26,7°CD B, 19,4°CWB, outdoor temperature: 35°CDB, AHRI 1230:2010, power input indoor units (duct type) included. As per AHRI/ SASO
ama
(3) indoor temperature: 29,0°CDB, 19,0°CWB, outdoor temperature: 46°CDB, ISO15042:2011, power input indoor units (duct type) included. As per ESMA
(4) indoor temperature: 26,6°CDB, 19,4°CWB, outdoor temperature: 48°CDB, AHRI 1230:2010, power input indoor units (duct type) included. As per MEW
(5) Heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, Eurovent 2015, equivalent
39
RXYSQ-TMY1B
RXYSQ_TMY1
52,000
(1) Indoor temperature: 26.7 ºCDB, 19.4 ºCWB, Outdoor temperature: 35 ºCDB, AHRI (4) Indoor temperature: 26.6 ºCDB, 19.4 ºCWB, outdoor temperature: 48 °CDB,
1230:2010, power input indoor units (duct type) included. As per AHRI/ SASO AHRI 1230:2010, power input indoor units (duct type) included. As per MEW
(2)
(5) Heating capacities are based on indoor temperature: 20 ºCDB, outdoor
and listing of the 50Hz models only. As per Estidama. temperature: 7 ºCDB, 6 ºCWB, Eurovent 2015, equivalent
(3) Indoor temperature: 29 ºCDB, 19 ºCWB, outdoor temperature: 46°CDB,
ISO15042:2011, power input indoor units (duct type) included. As per ESMA.
40
RWEYQ-PYL
Standard operation
OUTSIDE UNITS
Heat Pump/Heat Recovery
Notes: 1. Specifications are based on the following conditions; 2. 1. In the case of heat pump system, suction gas pipe is not used.
•Cooling: (*1) Indoor temp.: 27°CDB, 19.5°CWB/inlet water temp.: 30°C 2. In the case of heat recovery system.
(*2) Indoor temp.: 27°CDB, 19.0°CWB/inlet water temp.: 30°C 3. In the case of heat pump system.
•Heating: Indoor temp.: 20°CDB/inlet water temp.: 20°C 3. This unit cannot be installed in the outdoors. Install indoors (Machine room, etc).
•Equivalent piping length: 7.5 m 4. Ambient temperature at 0–40°C. Heat rejection from the casing: 0.71 kW/10 HP.
•Level difference: 0 m 5. Connectable to closed type cooling tower only.
• Please be sure to refer to the Engineering Data for facility design.
41
Notes:
42
We’re here to help you!