Units system: SI
File name: \
Design Results
GENERAL INFORMATION:
C1 : 1.2DL+1.6LL
DC1 : 1.2DL+1.6LL
Materials
General status : OK
COLUMN DATA : 1
Geometry
Longitudinal : 4-#6
Transverse : 15 #3 @ 250.00mm
Design parameters
--------------------------------------------------------
Lu[mm] 4350.00 4350.00
K 1.00 1.00
Cm 0.00 0.00
--------------------------------------------------------
Forces
------------------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------------------------------------------------------------------------------------------------------
RESULTS OF COLUMN: 1
Column status : OK
Biaxial compression
Controlling condition : C1
--------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------
Condition Pos. *Mnxx *Mnyy Mc/(*Mn) Pu/(*Pn) Asreq/Asprov Demand: Capacity Ratio
[KN*m] [KN*m]
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Shear
S provided : 250.00 [mm] S required : 300.00 [mm]
--------------------------------------------------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------------------------------------------------
Notes
* Each column is verified considering only the forces at the ends of the member.
* Lu = Unsupported length.
* Mc = Factored moment to be used for design. Considers the slenderness effects of the column. Mc = Mu* ns.
* Mc/(*Mn) = Strength ratio. The bar graphs indicate the relative ratio of Mc/(*Mn) for each load condition. If a bar is shown in red the ratio is greater
than one.