Compound hydrocarbon of coal tar origin as carrier Synthetic Substrate such as FRP Tissue reinforced with glass fibre Reinforcement mess. Separator Plastic (to be removed) Thickness As desired between 1.5 mm to 4.0 mm with tolerance of ± 10% Width (mm) 200, 250, 333, & 500 with tolerance of ± 10% Average Weight 1.50 kg / sq. metre / mm. thickness Compound :- Softening Point (R & B), °C Between 65 & 121 Needle Penetration at: (25°C / 100gms / 5secs, 10-1mm) Between 1 & 20
Filler Content, w/w % Between 20 & 35
Adhesion Test ( to be conducted Passes Test as per IS –15337–2003 (Sec. 7.1) at least 72 hours after application) Between 10 kV and 15 kV depending on tape thickness as per Holiday Test Voltage IS –15337–2003 (Sec 7.2). Direct Impact Test Passes Test as per IS–15337–2003 (Sec 7.3). 2 mm tape = 3.0 N/mm tape width Breaking Load in the 3 mm tape = 4.0 N/mm tape width longitudinal direction 4 mm tape = 5.0 N/mm tape width Insolubility in Petrol 95 % w/w minimum (after immersion for 24 hours) Cathodic Disbondment Test Passes Test as per IS–15337–2003 and BS-4164-1987 (at least once in a year) Microbiological Corrosion Resistance Test Passes as per Annex–E of IS–15337–2003 (at least once in a year) Service Temperature , °C 60 Maximum In rolls of 10 metres length for 1.5 mm & 2.0 mm thick tape and in rolls of 5 metres length for other thicknesses. Rolls of 500 mm Supply width will be packed in polybags. Rolls wound around a paper core. To be handled carefully and stored vertically under a shed away Storage from direct sun & any source of flame.
This tape also meets the specifications of American Water Works Association Standard AWWA – C 203 and British Standard BS-4164.