GENERAL FEATURES
Fully equipped charging station for management of AC and DC conductive
charging of Electric Vehicles. Juice Station charges two vehicles at the same
time with high speed (up to 50 kW).

The station offers the following functions:


Access to charging procedure via mobile APP or via RFID card

Real time communication with the remote center EMM Platform via GPRS/UMTS for the
monitoring and controlling of the charging station

Remote control of charging process

User interface to support the customer in the charging sessions and to provide
charging status (kWh and timing)

Data acquisition and transmission for each charging process and all diagnostic alarms

Able to be integrated into Smart Charging Logics thanks to specific algorithm and advanced
smart metering functions (real-time modulation of charging process by the EMM Platform)

The DC outputs allow just one charging at the same time, while the AC charging
can be active together with DC charging
Users instructions
The access to charging process is performed automatically on behalf of the customer,
according to the following steps: 


Identify yourself before gaining access


to the service with an App on smartphone;
or by means of an RFID (Wireless) Smart Card

Await a feedback from the charging station

Connect the cable and the recharge


session starts automatically

Intended use
PUBLIC PRIVATE
Charging station installed in a public area Charging station installed in a private area,
or in a private area with public access, available to a limited group of users,
open to all type of customers. for private charging only.

POWER SUPPLY:


Three-phase 400 VAC, 50Hz


2 MID certified bi-directional electronic meters


DC output AC output
Connector type Socket outlet
CHAdeMO CCS2 2 type 2

Name Code 120 A - 500 V 120 A - 500 V 43 kW 22 kW

1.00JUDA0503ECEU-
Enel X JuicePUMP 50 Trio 43
SLTCA4-000 Trio 43

1.00JUDA0503ECEU-
Enel X JuicePUMP 50 Trio S22
SMSCA4-000

1.00JUDD0503ECEU-
Enel X JuicePUMP 50 Duo
SYTCA4-000

Enel X JuicePUMP 50 Duo 1.00JUDA0503ECEU-


CHAdeMO+43 SETCA4-000

Enel X JuicePUMP 50 Duo 1.00JUDA0503ECEU-


CHAdeMO + S22 SGSCA4-000

Enel X JuicePUMP 50 Duo 1.00JUDA0503ECEU-


CCS2 + 43 SHTCA4-000

Enel X JuicePUMP 50 Duo 1.00JUDA0503ECEU-


CCS2 + S22 SISCA4-000

Efficiency greater than 95% Power factor greater than 0.97

ENVIRONMENTAL OPERATING CONDITIONS


Operating temperature: from -25°C to +50°C Charging station IP protection rating: IP55
Relative humidity: from 5% to 95%
 Charging station IK protection rating: IK10
Atmospheric pressure: from 860 hPa to 1,060 hPa

During the installation, pay attention to indications and requirements for the construction
of the plinth (reported in the installation guide), based on wind speed and ground surfaces.

MAIN COMPONENTS AND FUNCTIONALITIES. CONDITIONS


Smart Meter: 2 MID Smart Meter
 8” display touch screen

TLC Modem (GSM/GPRS/UMTS) with SIM
 Languages: as default English, Spanish, Italian;
RFID reader in compliance with standards: ISO/ customizable with all languages with the support
IEC 14443A and ISO/IEC 14443B of the customers
Emergency stop push button


Input double insulated cable.


RCD and MCB Protection.

DC output

RCD–TypeB30mA–125A
MCB – D80


AC output

RCD–TypeB30mA–80A
MCB – D80
REFERENCE STANDARDS. TECHNICAL CHARACTERISTICS

IEC 61851-21-2
Electric vehicle conductive charging system – Part 21-2: Electric vehicle
requirements for conductive connection to an AC/DC supply – EMC requirements
for o board electric vehicle charging systems.

IEC 62196-1
Plugs, socket-outlets, vehicle couplers and vehicle inlets – Conductive charging
of electric vehicles – Part 1: General requirements.

IEC 62196-2
Plugs, socket-outlets, vehicle couplers and vehicle inlets – Conductive charging
of electric vehicles – Part 2: Dimensional compatibility and interchangeability requirements
for AC pin and contact-tube accessories.

IEC 62196-3
Plugs, socket-outlets, vehicle couplers and vehicle inlets – Conductive charging
of electric
vehicles – Part 3: Dimensional compatibility and interchangeability requirements
for DC and AC/DC pin and contact-tube vehicle coupler.

IEC 60068 Environmental testing.

COMMUNICATION CHARACTERISTICS

The communication with remote center backend is based either on the OCPP 1.6 SOAP,
or Enel Proprietary protocol when the backend is the EMM platform.