Anda di halaman 1dari 6

ACQUITY UPLC

H-Class PLUS
PERFORMANCE THAT ADVANCES YOUR LAB
TRANSFORM STANDARD PROCEDURES INTO ULTIMATE PERFORMANCE

As an analytical laboratory, you solve problems and provide scientific information to other
business units within your company. You require scientific tools that give you definitive results.
You need to deploy analytical tools that support a diverse range of samples while fitting into your
existing laboratory workflows. What you don’t need is to compromise the quality of data
or timeliness of the result.

The ACQUITY™ UPLC™ H-Class PLUS System is the next evolution of quaternary based
UltraPerformance instrumentation, providing the highest resolution of any quaternary LC system.
Whether your goal is to rapidly develop new methods or to routinely analyze large numbers of
incoming samples, the ACQUITY UPLC H-Class PLUS System can help you decrease the time to
result, while increasing the depth and quality of information received from your sample analysis.

SYSTEMS THAT MEET YOUR NEEDS FOR TODAY AND TOMORROW


■■ Improve laboratory productivity by transitioning methods to UPLC Technology

■■ Leverage advanced tools to simplify and streamline your method development workflow

■■ Improve the characterization of your most complex samples through enhanced resolution

■■ Increase the analytical value of your samples by leveraging optical and mass information

■■ Match the need of your laboratory through support of your existing HPLC, UHPLC, and UPLC methods
HIGHEST RESOLUTION OF ANY QUATERNARY LC SYSTEM

Wide range of detection capabilities


Low dispersion
UPLC-optimized detectors to match your
True UPLC performance with band spread of less application needs, including photodiode array,
than 10 µL for highest chromatographic resolution. UV/Vis, fluorescence, refractive index, evaporative
light scattering, and mass detection.

Versatile column management

Support for analytical LC column dimensions up to Flexible sample support


300 mm with capacity to automatically select
between as many as six analytical columns. Accepts either vials or ANSI well plate
Equipped with independently controlled temperature formats. Extend capacity for high
zones, active pre-heating, and eCord™ Intelligent throughput and open access environments
Chip Technology for Waters™ columns. with the optional Sample Organizer.

Optional fraction collection

Temperature controlled and Flow-through-needle injector


compatible with narrow UPLC peaks.
Volume range of 0.1 to 1000 µL and ultra-low
carryover performance compatible with your
Gradient SmartStart
most sensitive LC-MS applications.
Easily adjust for system volume differences when
transferring methods from an alternative LC
Auto•Blend Plus™ Technology
system without alteration to the method table.
Program gradients directly in terms of
Quaternary solvent blending pH, molarity, or organic composition
to minimize manual mobile phase
Delivering precise and accurate separations at preparation, reduce human error,
pressures up to 15,000 psi. An optional solvent and accelerate method robustness
select valve adds access to an additional six testing for chromatographic methods.
solvents. Automated solvent compressibility,
integrated solvent degassing, and programmable
seal wash maximize flow accuracy, precision,
and reliability.
www.waters.com/hclassplus
DISCOVERING THE BEST METHOD Acetonitrile Methanol

GETS YOU THE BEST RESULTS 0.6 0.6

AU
AU
0.3 0.3
In method development, whether you use a step-wise CSH C18 CSH C18
0.0 0.0

approach, systematic screening, or a Quality by Design 0.6 0.6

(QbD) protocol, you encounter the same obstacles.

AU
AU
0.3 0.3
CORTECS C18+ CORTECS C18+
0.0 0.0

■■ What conditions should I investigate? 0.6 0.6

How do I track my peaks as conditions change?

AU
AU
■■ 0.3 0.3
CSH Phenyl Hexyl CSH Phenyl Hexyl

How can I reduce the time it takes to develop a robust method?


0.0 0.0
■■
0.6 0.6

AU
AU
0.3 0.3
The ACQUITY UPLC H-Class PLUS System simplifies and 0.0
HSS PFP
min 0.0
HSS PFP
min
0.0 1.0 2.0 3.0 4.0 5.0 0.0 1.0 2.0 3.0 4.0 5.0
streamlines your method development workflow. With
automated column selection from up to six, independently In developing a method for metoclopramide and its related components,
controlled column temperature zones, a number of selectivity the ACQUITY UPLC H-Class PLUS System was configured to automatically
screen multiple column and eluent combinations to identify the separation
choices can be easily, and quickly, screened. By incorporating conditions that provided the best chromatographic resolution.
the optional solvent select valve, mobile phase selectivity can
be expanded from four to an additional six mobile phase lines to augment its standard quaternary solvent blending.

Combining these system capabilities with the Empower™ Sample Set Generator can help you to completely automate your
method development experiment. And with the ACQUITY QDa™ Detector, method development can be significantly accelerated
by utilizing mass information to track the movement of peaks when evaluating different method conditions.

ONLINE ELUENT BLENDING – 1.00 RCA Irbesartan

ANY BUFFER, ANY SOLVENT, ANY pH


AU

0.50 pH = 3.0
0.00

Auto•Blend Plus Technology automatically blends your mobile 0.84 RCA Irbesartan
AU

0.42 pH = 3.1
phase to a specified pH and ionic strength or organic modifier
percentage, for any set of analytical conditions you need. By 1.20 Coelution
AU

0.60 pH = 3.2
leveraging this novel technology, the ACQUITY UPLC H-Class
0.00

0.80 Irbesartan RCA


PLUS System frees up analysts time to perform more value-
AU

0.40 pH = 3.3
0.00

added activities by reducing the number of mobile phase 0.80 Irbesartan RCA
AU

pH = 3.4
buffers that need to be manually prepared.
0.40
min
3.12 3.25 3.38 3.51 3.64 3.77 3.90

Whether you are running biomolecules and require pH gradients


The USP assay for Irbesartan requires that the eluent be adjusted to pH 3.2,
for charge variant analysis, or you are performing small molecule however this results in a co-elution of the API and its related compound.
method robustness testing and want to test small variations in By making automated, online adjustments to the pH in 0.1 increments using
pH, Auto•Blend Plus Software allows you to program an infinite Auto•Blend Plus, a more robust set of pH conditions can be found.

set of conditions for any analytical method type.


TAKE YOUR METHODS TO THE 0.05
2 3

NEXT PERFORMANCE LEVEL


0.04
UPLC
0.03 Column: 2.1 x 50 mm, 1.7 µm
Leverage the benefits of UPLC Technology USP Res = 2.7
Flow rate: 0.43 mL/min

AU
0.02
1
Solvent consumed: 3.8 mL/injection

to improve your existing HPLC methods.


0.01 4 5 6 7

0.00

By scaling your methods to UPLC, your -0.01 min


1.40 1.75 2.10 2.45 2.80 3.15 3.50 3.85 4.20 4.55 4.87
4.87
laboratory will benefit from the combination 0.05

0.04
UHPLC
of increased resolution, sensitivity, and 0.03 Column: 3.0 x 75 mm, 2.5 µm
Flow rate: 0.60 mL/min
speed that comes with modern small USP Res = 2.7

AU
0.02 Solvent consumed: 11.6 mL/injection
0.01
particle chemistries. 0.00

-0.01 min
With novel method conversion tools such 0.05
3.75 4.50 5.25 6.00 6.75 7.50 8.25 9.00 9.75 10.50
10.8
as the Columns Calculator and the 0.04
HPLC
0.03
Column Coach, the process of upgrading Column: 4.6 x 100 mm, 3.5 µm
Flow rate: 1.0 mL/min

AU
0.02 USP Res = 3.0
Solvent consumed: 36 mL/injection
your methods has never been easier. 0.01

0.00

-0.01 min
6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5
20.0

The USP analysis of diclazuril and organic impurities was scaled from HPLC to UHPLC to UPLC.
The UPLC method resulted in a 4x reduction in run time with a 10x reduction in solvent
consumption resulting in improved sample throughput and reduced cost per analysis.

UPLC TOMORROW, BUT HPLC TODAY Compound:


0.027
1. Impurity C
Adopting a new analytical technology that Agilent 1100 2 2. Clozapine
0.018 3. Impurity D
improves laboratory efficiency is advantageous LC System 4. Impurity A
AU

5. Impurity B 5
for supporting your new projects and products. 0.009 1 3 4

But what about all of your existing HPLC 0.000

analyses that support the products you have 0.027

today? Designed to accommodate all of your 0.018


ACQUITY UPLC 2
H-Class PLUS
LC method needs, the ACQUITY UPLC H-Class
AU

0.009 System 1 3 5
4
PLUS System is ideally suited to future-proof
0.000
your laboratory, enabling the support of existing min
4.0 5.0 6.0 7.0 8.0 9.0 10.0
HPLC methods now, and provide significant
productivity and cost benefit when utilized For the USP assay of clozapine, the system suitability solution was run on both an Agilent
for UPLC methods. 1100 LC System and the ACQUITY UPLC H-Class PLUS System. For this gradient method,
equivalent chromatographic results were achieved on both systems.

www.waters.com/hclassplus
www.waters.com/hclassplus

For your local sales office, please visit www.waters.com/contact

Waters Corporation
34 Maple Street
Waters, The Science of What’s Possible, ACQUITY, UPLC, Empower, Auto•Blend Plus,
Milford, MA 01757 U.S.A.
eCord, and QDa are trademarks of Waters Corporation. All other trademarks are the
property of their respective owners.
T: 1 508 478 2000
F: 1 508 872 1990
©2018 Waters Corporation. Printed in the U.S.A. April 2018 720003268EN LM-SIG www.waters.com