Anda di halaman 1dari 2

CAC‐Hyperfluid

Plus (H2)
Superplasticiser for Low Grades Concrete based on Poly-carboxylic Ether

CAC-Hyperfluid Plus (H2) is a (H2) to dry mixes or cement is not


superplasticising admixture to produce recommended.
lower grades concrete where the cohesive,
workable and pumpable concrete is required. Thorough mixing is essential and after addition
of CAC-Hyperfluid Plus (H2), minimum
AREA OF APPLICATION: mixing cycle of 60 seconds for forced action
mixers is recommended.
 Ready Mix Concrete for lower grades
 Site Mixed Concrete DOSAGE:
 Regular Strength Concrete upto M45
 Suitable for crushed sand concrete As a starting point, a dosage range of 0.5kg to
 Pumped concrete 1.2kg per 100kg of cementitious materials is
recommended. Optimum dosage of CAC-
Primary uses to obtain- Hyperfluid Plus (H2) should be determined in
trial mixes. Please consult CAC Pvt. Ltd.
 Good dispersion resulting in High Technical staff for further information.
workability & superb slump retention.
 Improves cohesiveness & pumpability. COMPATIBILITY:
 Increases early & ultimate strengths
 Increases Flexural strength & E-modulus CAC-Hyperfluid Plus (H2) is compatible with
 Can be placed and compacted in all types of cements and CAC-Retardplast
congested reinforcements without series of products. If more than one admixture
vibration & improves surface finish. is to be used in concrete, they must be
 Increases durability & impermeability dispensed separately with prior approval
 Ideal for use in low fines, crushed sand received from CAC Pvt. Ltd. Technical Services.
concrete mixes.
CAC-Hyperfluid Plus (H2) is suitable for
STANDARDS: mixes containing:

ASTM C 494 – Type G  Micro-silica


IS 9103 : 1999  Pulverised Fly Ash
 Ground Granulated Blast Furnace Slag
METHOD OF APPLICATION:
WORKABILITY:
Add 80-90% water to the concrete based on Mix
Design by weight. The correct quantity of CAC- CAC-Hyperfluid Plus (H2) ensures that
Hyperfluid Plus (H2) should be measured concrete remains workable in excess of 3 hours
with recommended dispenser and should be at 200C. Workability loss is dependent on
added to the concrete with remaining mixing temperature, type of cement, nature of
water. Allow to mix it for recommended mixing aggregates, the method of transport and initial
time. The addition of CAC-Hyperfluid Plus workability.

01 of 02
CAC‐Hyperfluid Plus (H2)
It is strongly recommended that concrete should The shelf life of the product is 1 year when
be properly cured particularly in hot and dry stored as recommended.
climates.
PACKAGING:
TECHNICAL PROPERTIES:
CAC-Hyperfluid Plus (H2) is available in 250
Appearance Light Brown Liquid kg drum and in tanker (10 MT) on demand.
Base material modified Poly-carboxylic
Ether STORAGE:
Specific Gravity 1.080 + 0.020
@250C CAC-Hyperfluid Plus (H2) must be stored at
Chloride content Maximum 0.2% above 50C temperature. Store under cover,
pH Minimum 6 protect it from direct sunlight. Failure to comply
with recommended storage condition may result
in premature deterioration of the product or
Mechanism of action:
packaging
Conventional Superplasticiser, based on
EFFECTS OF OVER-DOSAGE:
Sulphonated Naphthalene or Melamine
Formaldehyde condensates, at the time of A severe over-dosage of CAC-Hyperfluid Plus
mixing getting absorbed onto the surface of (H2) will result in the following:
cement particles. This absorption takes place at
very early stage in the hydration process. The  Retardation of Setting Time
sulphonic groups of the polymer chains  Increase in workability / segregation
increases the negative charges on the surface of  Slight increase in air entrainment
the cement particle and the dispersion of the
SAFETY PRECAUTIONS:
cement occurs by Electrostatic Repulsion.
CAC-Hyperfluid Plus (H2) is a non-toxic and
CAC-Hyperfluid Plus (H2) is differentiated
inflammable. When in contact with the skin, it
from conventional superplasticisers in that it is
should be washed with cold water.
based on unique carboxylic ether polymer with
long lateral chains. This greatly improves the Disclaimer:
cement dispersion. At the start of the mixing The product information & application details given by the
company & its agents has been provided in good faith &
process the same electrostatic dispersion takes meant to serve only as a general guideline during usage.
place as described above; but the presence of Users are advised to carry out tests and take trials to ensure
the lateral chains, linked to the polymer on suitability of products meeting their requirement prior to
full scale usage of our products. Since the correct
backbone, generate a Steric Hindrance which identification of the problems, quality of the other materials
stabilizes the cement particles capacity to used and on-site workmanship are factors beyond our
control, there are no expressed or implied guarantee /
separate & disperse. This mechanism provides warranty as to the results obtained. The Company does not
fluid concrete with greatly reduced water assume any liability or any consequential damage for
unsatisfactory results, arising from the use of our products.
demand with longer retention.
Ver.: CAC-H-Plus H2/1/1112 02 of 02
Concrete Additives & Chemicals Pvt. Ltd.
Plot No.-W/11, TTC Industrial Area, MIDC,
Pawane, Navi Mumbai-400705.
Tel: +91-22-27681365 / 27632083, Fax:+91-22-27686787
Website: www.cac-admixtures.com AN ISO 9001 CERTIFIED COMPANY