 DECLOGGED LT-265-1 lead lines as noticed erratic indication, with Instrument Technician .

 Weekly test run for GD-9950 conducted,ok. Newly installed TACHOMETER is working properly.
 ACID WASHING of Biocide cells started at 1730H
 Backwashed dual media filter/online filtration unit/switched G9108 t0 G9109

2. Elect'l. Mtce conducted PDM/Regreasing of GM-9201/9202 & KM-261/262.


3. MTCE rectified problem of raw water pump "B"

5. Painting of V-9301 local panel and housing started by MTCE.


6. Mtce installed support at pressure indicator of E-9253C.
9. Monthly car sealed valves inspection done by group B.

3. Elect'l Mtce conducted PDM of GM -9250/9251, GM-202 & KM-261/262


5. Inst. Tech'n. Conducted PM/calibration of C-270 deluge system.
6. Inst. Tech'n. rectified problem on K-216 deluge system

2. Top up methanol of G-202 from 20 to 90%

1. Graphics modification of raw materials receiving and storage 1 done by PAD


2. Erection/modification of scaffolding for the rectification of firewater leak at C-390 deluge line
3. Rectify excessive packing leak at G-9251.

JAN 10

1.PM test of beacon light at Jetty1


3.PM of DCS work station
4.vibrationsurvey of G-9201/02
5.welding/rectification of leak at SW inlet strainer main

1. Valve greasing of SW outlet valve Bypass E-9253B outlet valve/ E-9253A main valve
2.Electrician replaced temperature gauge at EDG -9950 with new spare.
3.Installation of industrial outlet at filtration unit

2. Analyzer conducted PM/inpection of chlorine analyzer at Filration area.


3. IED checked/calibrated pressure switch of C-220 deluge system.

1. EESI Contr. installation of scaffoldings, power cable, fixture & bracket support/ installation & erection of steel post w/
2. Crane mobilization/demobilization for transfer of equipments/materials at BFO Jetty wharf area.
3. Mechanical Mtce. preparation activities for rehabilitation of DMF i.e. blinding and re-routing of RW flow going to FW
4. Behn Meyer Contr. started rehabilitation of C-9106C1 (DMF); started removal of the vessel's content.

5. Repair of fire house cabinet door at RM Jetty 1.


3.G-3011B changed oil
4.GD 9252 changed oil at NDE part
5.Inspection of Junction Box LT221 TB-P / LT 221-1 TB
7.Inspection of JB LT 200-9
3. Mtce. cleaned inlet strainer of G-132/133.
4. MTCE. rectified exhaust manifold leak and fixed detached/broken clamp at turbo charger. For re-installation of insulat

1. Mechl mtce top up methanol at G-202.


2. Inspection personnel Ferdie Gamis conducted UT at C-9106C1.

2. Electrical conducted inspection of batteries of GD-9252 & GD-9203


3. Electrical PM conducted for Biocide unit (V-9206).