DATE 13-04-16 37 GUL DRIVE TRENCH & SHAFT
Vertical I Beam Moment & shear Capacity check (3.0 m Deep )

Type of I-Beam = 152x152x37 kg/m


Load Factor = 1
Spacing of I-Beam (m) = 1.50

Original Elastic modulus ,Wpl (mm3/m) = 273000


Elastic modulus with 15 % reduction = 232050

D = 161.8
t = 11.5

Area, A(mm2/m) = 1860.7


Area with 15 % reduction = 1581.6

Allowable yield stress,Py(N/mm2) = 275

Allowable moment capacity of I-Beam Mc,Rd(kNm/m) = Wpl fy / γmo


63.81

Maximum moment from plaxis analysis (kNm/m) = 39.26


(Moment * Spacing) = 58.9
(Factored moment) = 58.9 < 63.8

Allowable shear capacity of I-Beam VC,Rd(kN/m) = Av ( fy / √3 ) / γmo


= 251.1

Maximum shear from plaxis (kN/m) = 40.73


(Shear * Spacing) = 61.10
(Factored Force) = 61.1 < 251.1

OK