Anda di halaman 1dari 13

DEBOTTLENECKING STUDY PHE NSB-NSO

BASIC OF DESIGN NSO

A RP & AL

REV TANGGAL DESKRIPSI DISIAPKAN DIPERIKSA DISETUJUI PENGGUNA

PENGGUNAAN ATAU PENYALINAN KEMBALI DOKUMEN INI SECARA KESELURUHAN


ATAU SEBAGIAN

DILARANG KECUALI DENGAN IZIN TERTULIS DARI PEMILIK

JOB NO.

DOCUMENT NO.

DBSP-LU-DA-100-002
Debottlenecking Study PHE NSB NSO

LEMBAR PENGESAHAN

DIREKSI PEKERJAAN

Dr. Eko Waludi

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 2 [Type here]
Debottlenecking Study PHE NSB NSO

LEMBAR KONTROL REVISI

REV. NO TANGGAL DESKRIPSI

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 3 [Type here]
Debottlenecking Study PHE NSB NSO

Daftar Isi

1. Cluster I-IV ..................................................................................................................................... 5


a. Brief Cluster I-IV ........................................................................................................................ 5
b. Cluster IV (Operating Condition) ............................................................................................... 6
c. Assumption & Justification......................................................................................................... 7
2. NSO Off Shore ................................................................................................................................ 7
a. Brief Off-Shore ........................................................................................................................... 7
b. NSO Off-Shore (Operating Condition) ....................................................................................... 8
c. Assumption ............................................................................................................................... 10
3. South Lhoksukon .......................................................................................................................... 11
a. Brief South Lhoksukon ............................................................................................................. 11
b. SLS (Operating Condition) ....................................................................................................... 11
c. Assumption ............................................................................................................................... 12

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 4 [Type here]
Debottlenecking Study PHE NSB NSO

1. Cluster I-IV
a. Brief Cluster I-IV
Gambar berikut menunjukkan kondisi saat ini dari Area Arus Cluster I-IV yang diperoleh dari
site visit yang telah dilakukan. Pada area ini unit operasi yang masih aktif meliputi fan cooler, separator,
dehydration unit dan kompressor. Gas dari cluster 1,2 dan 3 dipisahkan pada cluster masing-masing
kemudian digabung dengan gas dari sls dan cluster 4 untuk masuk ke unit pengolahan pada cluster 4.
Unit proses pada cluster 4 meliput unit separasi, dehidrasi dan booster compressor K4920. Untuk
kondensat, hasil kondensat dari masing-masing cluster 1 dan 2 digabung di cluster 3 kemudian langsung
dikirim ke Point A. Kondensat dari SLS digabung dengan kondensat dari cluster 4 untuk di kirim ke
point A.

From SLS

D-419
P=313 Psig
Komposisi ? Pont A
Dehydration 76.5 MMscfd
K-4920A/B
Unit P=28 Psig
Cluster-IV T=100 F T=92 F
Wells P=30 Psig
T=151 F E-416A-H
E-466A-H D-416
D-466

432 BWPD
20.76 MMscfd D-418

Komposisi ? ?
Water
Fuel
0.4 MMscfd

Cluster-III T=?
Wells
P=65 Psig
D-336A-H
T=186 F
Komposisi ? D-316

Q=9 MMscfd
P=69 Psig 1248 BOPD
T=? T=166 F D-318
Cluster-II
Wells
P=71 Psig
D-226A-H
T=166 F
D-216
Water
Komposisi ? 1784 BWPD

Q=4 MMscfd
P=73 Psig
Cluster-I T=146 F
Wells
P=75 Psig
T=146 F D-116A-H
D-116

Gambar 2. Diagram Proses Area Arun Cluster I-IV

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 5 [Type here]
Debottlenecking Study PHE NSB NSO

b. Cluster IV (Operating Condition)


Beritkut ini adalah kondisi operasi actual dan design yang akan disimulasikan:

Actual Design Unit


MATERIAL BALANCE FEED
STREAM (CURRENT OPERATION)
- Flowrate MMscfd
- Pressure Psig, Psia
o
- Temperature C, oF
- Composition
GAS-LIQUID SEPARATION
Air Cooler (E-416A-H & E-466A-H)
HP, KW,
- Duty / Power Mmbtu/Hr
- Surface Area
- Inlet Gas Flow MMscfd
- Inlet / Outlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Vessel (D-416, D-466, D-417, D-467, D-
418)
- Dimensi / Size ft x ft
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Heat Exchanger (E-417, E-467, E-418 &
E-468)
- Inlet / Outlet Pressure (Hot Stream) Psig, Psia
o
- Inlet / Outlet Temperature (Hot Stream) C, oF
- Inlet / Outlet Pressure (Cold Stream) Psig, Psia
o
- Inlet / Outlet Temperature (Cold Stream) C, oF
REFRIGERTION SYSTEM
Vessel (D-301, D-351, D-341, D-3504, D-
3505, D-3506, D-3507, D-3508)
- Dimensi / Size ft x ft
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Air Cooler (E-301 & E-351)
HP, KW,
- Duty / Power Mmbtu/Hr
- Surface Area
- Inlet Gas Flow MMscfd
- Inlet / Outlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Heat Exchanger (E-3501, E-3502, E-3503,
E-3504, E-3505, E-3506)
Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 6 [Type here]
Debottlenecking Study PHE NSB NSO

Actual Design Unit


- Inlet / Outlet Pressure (Hot Stream) Psig, Psia
o
- Inlet / Outlet Temperature (Hot Stream) C, oF
- Inlet / Outlet Pressure (Cold Stream) Psig, Psia
o
- Inlet / Outlet Temperature (Cold Stream) C, oF
Pumps (G-301, G-302, G-341, G-351, G-
3501, G-3502)
- Inlet / Otlet Pressure Psig, Psia
- Outlet Liquid Flow USGPM
Compressor (K-3504 & K-3505)
- Inlet / Otlet Pressure Psig, Psia
- Inlet Gas Flow MSCFD

c. Assumption & Justification


Berikut ini adalah asumsi, keterangan serta justifikasi yang dilakukan terkait dengan
keterbatasan data dan informasi yang akan digunakan pada simulasi.

Data Keterangan Asumsi Justifikasi


Komposisi
Sudah tidak ditarik ke Perubahan komposisi
Komposisi Cluster
dilakukan belakang minor karena telah di
1,2 dan 3 upstream
pengambilan sample menggunakan campur di cluster
simulasi

2. NSO Off Shore


a. Brief Off-Shore
Gambar berikut menunjukkan kondisi saat ini dari Area NSO Platform yang diperoleh dari site
visit yang telah dilakukan. Pada area ini seluruh fasilitas masih aktif.

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 7 [Type here]
Debottlenecking Study PHE NSB NSO

Gambar 3. Diagram Proses Area NSO Platform

b. NSO Off-Shore (Operating Condition)


Beritkut ini adalah kondisi operasi actual dan design yang akan disimulasikan:

Actual Design Unit


MATERIAL BALANCE All STREAM
(CURRENT OPERATION)
- Flowrate MMscfd
- Pressure Psig, Psia
o
- Temperature C, oF
- Composition
GAS-LIQUID SEPARATION
Air Cooler (E-1501A/B/C/D dan E-1502)
- Duty / Power HP, KW, Mmbtu/Hr
- Surface Area
- Inlet Gas Flow MMscfd
- Inlet / Outlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Vessel (D-1501, D-1502, D-1503)
- Dimensi / Size ft x ft
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
DEHYDRATION UNIT
TEG Booster Pump (G-1504 A/B)
- Inlet / Otlet Pressure Psig, Psia
Glycol Contactor (C-1501 A/B)
- Inlet Gas Rate MMscfd
- Rate Glycol GPM

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 8 [Type here]
Debottlenecking Study PHE NSB NSO

Actual Design Unit


- Komposisi Glycol %
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Filter Separator (D-1509 A/B)
- Dimensi / Size ft x ft
- Inlet / Otlet Pressure Psig, Psia
FUEL GAS SYSTEM
Fuel gas TEG Absorber (C-1502)
- Inlet Gas Rate MMscfd
- Rate Glycol GPM
- Komposisi Glycol %
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Fuel Gas Scrubber (D-1512)
- Dimensi / Size ft x ft
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
GLYCOL REGENERATION
Heat Exchangers(E-1504, E-1505, E-
1506A)
- Inlet / Outlet Pressure (Hot Stream) Psig, Psia
o
- Inlet / Outlet Temperature (Hot Stream) C, oF
- Inlet / Outlet Pressure (Cold Stream) Psig, Psia
o
- Inlet / Outlet Temperature (Cold Stream) C, oF
Air Cooler (E-1506 B)
- Duty / Power HP, KW, Mmbtu/Hr
- Surface Area
- Inlet Gas Flow MMscfd
- Inlet / Outlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Vessel (D-1508 & D-1515)
- Dimensi / Size ft x ft
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Reboiler (B-1501)
- Duty HP, KW, Mmbtu/Hr
- Fuel Composition
o
- Operating Temperature C, oF
- Inlet Gas Flow MMscfd
Column (C-1503 & C-1504)

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 9 [Type here]
Debottlenecking Study PHE NSB NSO

Actual Design Unit


- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Filters(Y-1501 A / B & Y-1502)
- Inlet / Otlet Pressure Psig, Psia
Pumps (G-1501 A / B / C)
- Inlet / Otlet Pressure Psig, Psia
- Outlet Liquid Flow USGPM
CONDENSATE & WATER
TREATMENT
Vessel (D-1504)
- Dimensi / Size ft x ft
- Capacity BBLS
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Filters(Y-1508 A / B & Y-1509 A / B)
- Inlet / Otlet Pressure Psig, Psia
Pumps (G-1512 A / B & G-1513 A/ B / C)
- Inlet / Otlet Pressure Psig, Psia
- Outlet Liquid Flow USGPM
FLARE SYSTEMS
Vessel (D-1508 & D-1515)
- Dimensi / Size ft x ft
- Capacity BBLS
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Pumps (G-1502 A / B, G-1503 A/ B, G-
1505 A / B, G-1506)
- Inlet / Otlet Pressure Psig, Psia
- Outlet Liquid Flow USGPM

c. Assumption
Berikut ini adalah asumsi, keterangan serta justifikasi yang dilakukan terkait dengan
keterbatasan data dan informasi yang akan digunakan pada simulasi.

Data Keterangan Asumsi Justifikasi

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 10 [Type here]
Debottlenecking Study PHE NSB NSO

Data Keterangan Asumsi Justifikasi

3. South Lhoksukon
a. Brief South Lhoksukon
Gambar berikut menunjukkan kondisi saat ini dari Area SLS A yang diperoleh dari site visit
yang telah dilakukan. Pada area ini unit operasi yang masih aktif meliputi fan cooler dan 3 phase
separator.

Gambar 2. Diagram Proses Area SLS A

Pada gambar tersebut peralatan yang dalam kotak kelabu telah di non-aktifkan. Sedangkan yang
berada pada kotak berwarna biru gas di bypass dan dalam kotak berwarna merah unit tidak ada atau
dalam kondisi rusak.
b. SLS (Operating Condition)
Beritkut ini adalah kondisi operasi actual dan design yang akan disimulasikan:

Actual Design Unit


MATERIAL BALANCE FEED
STREAM (CURRENT OPERATION)

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 11 [Type here]
Debottlenecking Study PHE NSB NSO

Actual Design Unit


- Flowrate MMscfd
- Pressure Psig, Psia
o
- Temperature C, oF
- Composition
GAS-LIQUID SEPARATION
Air Cooler (E-1101 & E-1151)
- Duty / Power HP, KW, Mmbtu/Hr
- Surface Area
- Inlet Gas Flow MMscfd
- Inlet / Outlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Vessel (D-1101, D-1102, D-1103, D-1104,
D-419) Train #1
- Dimensi / Size ft x ft
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Vessel (D-1101, D-1102, D-1103, D-1104)
Train #2
- Dimensi / Size ft x ft
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
DEHYDRATION UNIT
Heater (Y-1101 B & Y-1151 B)
- Inlet / Outlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
Mixer (Y-1101 & Y-1151)
- Dimensi / Size ft x ft
- Inlet / Outlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF
- Inlet Gas Rate MMscfd
- Rate Glycol GPM
Vessel (V-1101-D1 & V-1151-D1)
- Dimensi / Size ft x ft
- Inlet Gas Flow MMscfd
- Inlet / Otlet Pressure Psig, Psia
o
- Inlet / Outlet Temperature C, oF

c. Assumption
Berikut ini adalah asumsi, keterangan serta justifikasi yang dilakukan terkait dengan
keterbatasan data dan informasi yang akan digunakan pada simulasi.

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 12 [Type here]
Debottlenecking Study PHE NSB NSO

Data Keterangan Asumsi Justifikasi

Dok. No DBSP-LU-DA-100-002
Basic Of Design NSO 13 [Type here]