Anda di halaman 1dari 9

Fast Track Troubleshooting

IMPORTANT SAFETY NOTICE – “For Technicians Only” This service data sheet
Model: is intended for use by persons having electrical, electronic, and mechanical experience and
RS22HD knowledge at a level generally considered acceptable in the appliance repair trade. Any attempt to
repair a major appliance may result in personal injury and property damage. The manufacturer or
seller cannot be responsible, nor assume any liability for injury or damage of any kind arising from
the use of this data sheet.

Bulletins: Publication # MY RS22 Production Date 06/17/2014


Support Information:
HELP: 1-888-751-4086 (Tech Sup. – ASC/SSD)
1-866-894-0637 (Tech Sup. - FE/ME)
GSPN: http://gspn3.samsungcsportal.com/main.jsp
Cooling-Off Mode PLUS ONE: http://my.plus1solutions.net/clientPortals/samsung

1) If Power Freeze Key + Freezer Key are


pressed simultaneously for 5 seconds during Force Mode:
normal operation, Cooling Off mode will be
started with buzzer sound(ding-dong).
2) If Power Freeze Key + Freezer Key are
pressed one more time, Cooling Off mode will
be canceled.
3) If Cooling Off mode is selected, blinks "O-
FF" on the temperature setting display of the
panel and it indicates the refrigerator has
entered the Cooling Off mode.

Self Diagnosis: Wait 5 Seconds between button pushes


Press Power Freeze and Lighting for 8 Press the Power Freeze and the Fridge buttons
seconds
See chart starting page 3 for 8 seconds at the same time.
Press the Power Freeze and the Fridge buttons for more than 8 seconds at
the same time.Then, the Freezer & Fridge temperature display will be turned
off and the Test mode begins.

Forced Operation (FF) → R off Forced Operation(OF r) → Forced Fridge


Defrost(rd) →
Forced Fridge/Freezer Defrost (Fd) → Cancelled (Normal Operation)
• The recommended way to cancel the Test function is turning off an on the
unit.

Load Mode:
Press Power Freeze and Lighting for
6 seconds, until the display blinks.
Then press Fridge.
See chart starting on page 5
✽ Self-diagnosis checklist

Display Operation condition durind error

F-
R-
Item Description Conden Defro
Freez Fridg F- R- Defros DAMP
ser st
er e FAN FAN t ER
Fan Heate
Heater
r

1 E F-SENSOR Open Short O O O O O O

2 E R-SENSOR Open Short O O O O O O

F-DEF-
4 E Open Short O O O O O O
SENSOR

R-DEF-
5 E Open Short O O O O O O
SENSOR

6 E EXT-SENSOR Open Short O O O O O O

HUMIDITY-
13 E Open Short O O O O O O
SENSOR

Freezer Fan
21 E F-FAN Error O O O O O O
Trouble

Freezer Fan
22 E R-FAN Error O O O O O O
Trouble

Condenser Fan
23 E C-FAN Error O O O O O O
Trouble

F-Defrost Defrost
24 E Error Trouble(OverHe O O O O O O
ating)

R-Defrost Defrost
25 E Error Trouble(OverHe O O O O O O
ating)

I/M Ice Ejection


ICE MAKER
26 E horizontal O O O O O O
Error
positioning error.
Display Operation condition durind error

F- R-
Item Description Conden
Freez Fridg F- R- Defros Defros DAMP
ser
er e FAN FAN t t ER
Fan
Heater Heater

Communicati Communication
41 E on Error Trouble between O O O O O O
Panel ↔ Main Panel and Main

Communicati Communication
on Error Trouble between
44 E O O O O O O
Main ↔ Main and
Inverter Inverter

Communicati Communication
on Error Trouble between
46 E O O O O O O
Micom and I/O
I/O Expander Expander

The F ON/O
compartment FF
Freezer (When
abnormal
compartment the
71 E hightemperat door
O O O O O
temperature or
ure indicator is
door open error.
blinks opene
d)

The R ON/O
compartment FF
Fridge (When
abnormal
compartment the
72 E hightemperat O door
O O O O
temperature or
ure indicator is
door open error.
blinks opene
d)

Comp When the


81 E starting Compressor fails O O O O O O
Failure Error starting
Display Operation condition durind error
F- R-
Item Description Conden
Freez Fridg F- R- Defros Defros DAMP
ser
er e FAN FAN t t ER
Fan
Heater Heater
Comp IPM When there is a
82 E O O O O O O
Fault Error IPM Fault error
Comp
When there is
Abnormal
abnormal current
83 E current O O O O O O
detected at the
Detection
Compressor
Error
Comp Motor When there is a
84 E Locked Over Compressor O O O O O O
RPM Error restriction error
Comp under When there is a
85 E O O O O O O
voltage Error low voltage error
When there is a
Comp over
86 E over voltage O O O O O O
voltage Error
error

Load Mode Checklist

N
Item Description Display Digital no.
O
FRIDGE FAN R-FAN HIGHESET Fridge second digit
1 HIGHEST RPM a, b
FRIDGE FAN Fridge second digit
2 HIGH
R-FAN HIGH RPM
a
Fridge second digit
3 FRIDGE FAN LOW R-FAN LOW RPM
b
FRIDGE
R-DEF HEATER Fridge second digit
4 DEFROST
ON c
HEATER
OVER LOAD Over 34ºC (93ºF) Fridge second digit
5 MODE Ambient Temp e
N
Item Description Display Digital no.
O
Less than 21ºC
LOW TEMP
6 MODE
(70ºF) Ambient Fridge second digit f
Temp
Exhibition Mode Fridge second digit
7 EXHIBIT MODE
On g
Fridge second digit
8 ICE FULL Bucket Ice Full
d
Freezer second digit
9 COMPRESSOR COMP On
a
1 FREEZER FAN F-FAN HIGHEST Freezer second digit
0 HIGHEST RPM b, c

1 FREEZER FAN Freezer second digit


F-FAN HIGH RPM
1 HIGH b

1 FREEZER FAN Freezer second digit


F-FAN LOW RPM
2 LOW c

FREEZER
1 F-DEF HEATER Freezer second digit
DEFROST
3 ON d
HEATER
1 CONDENSER FAN C-FAN HIGHEST Freezer second digit
.
4 HIGHEST RPM e, f
1 CONDENSER FAN Freezer second digit
C-FAN HIGH RPM
5 HIGH e

1 CONDENSER FAN Freezer second digit


C-FAN LOW RPM
6 LOW f

1 DISPENSER DISPENSER
Freezer first digit g
7 HEATER HEATER ON

1 WATER TANK Fridge Water


Freezer first digit a
8 HEATER Tank Heater On

1
FREEZER VALVE F Valve On Freezer first digit b
9
2
FRIDGE VALVE R Valve On Freezer first digit c
0
2 NORMAL ⑤ & ⑥ All Off Fridge second digit
1 CONDITION (22~33ºC 71~92ºF) e,f LED all Off
Connector Layout with part position (Main Board)
Model : RS22HD
Connector Layout with part position (Inverter Board)

Anda mungkin juga menyukai