Anda di halaman 1dari 3

USP

MICROCODE VERSION 50-09-12-00/00


RELEASED 04/30/2007

Newly supported features and functions for Version 50-09-12-00/00


1. Mainframe & OPEN System
NONE

2. Mainframe
2-1 Support TCZ initial copy for URZ initial copy
Description This function performs True Copy for z/OS initial copy for a UR for z/OS pair in the
suspend state, aiming to improve the performance of UR for z/OS initial copy by
making a set of processing steps shown below as one script that is executed with a
command issued from BCM. A set of processing steps: URZ initial copy (No copy)
> URZ suspend > TCZ initial copy > TCZ delete > URZ resync. To use the
function, the following P.P are required to be installed: True Copy for z/OS, True
Copy for z/OS Asynchronous, Universal Replicator for IBM z/OS

New System Option Mode 474 is available to use the function.


Public Mode – No Permission Required to Use. The option must be set to ON for
both MCU and RCU to enable the function, and set to OFF after executing the
script.
Changed Part DKCMAIN
Note For MIRRID# of UR for z/OS, use numbers other than 0.
When using the function in the Multi Target/ Cascade configuration, first create a
UR for z/OS pair.
For information on how to use the script of Mode 474 please review actual ECN
Documented None

3. OPEN System
NONE

The change of contents for Version 50-09-12-00/00


1 Improper display of Shredding results
Phenomena Although write processing of Shredding ended abnormally,
Storage Navigator showed the results as normal except that of the
last processing. SSB: 7b0a reported, which means some part of
LDEV format processing ends abnormally.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs while performing Shredding with multiple
write processes onto the HDD, and errors occur during the write
process except for the last time.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-09-12-00/00
Category Volume Shredder
Changed Part DKCMAIN

HDS Confidential 1 of 3
2 Unable to register WWN
Phenomena Regarding LUN security:
1. A WWN registered no longer existed.
2. An attempt to re-register the WWN mentioned in #1 failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs with the following conditions #1 and #2, or
#1and #3 met.
1. Set or change a WWN from RMI I/F (HDVM, etc.)
2. Start the maintenance screen from SVP (This operation starts
configuration information acquisition processing.)
3. Re-execute the configuration information acquisition processing
on the SVP maintenance screen
Affected Products/Version SVP: All
Fixed Product/Version SVP: 50-09-06-00/00
Category LUN Manager
Changed Part SVP

3 Increased amount of Write pending on RCU at URZ


initial copy processing
Phenomena When performing UR z/OS initial copy in the mainframe
environment, the amount of Write pending on the RCU increased.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs with all the following conditions met.
1. Mainframe environment
2. Perform UR for z/OS initial copy or Resync
Affected Products/Version DKCMAIN: 50-05-40-00/00 and higher
Fixed Product/Version DKCMAIN: 50-09-12-00/00
Category Universal Replicator for z/OS
Changed Part DKCMAIN

4 HDD command response improvement


Phenomena HDD micro-program modified to improve the command response
time under low IO operation.
Severity (High, Medium, Low) Low
Affected Products/Version DKU DKR2F-K: 00-00-D8
Fixed Product/Version DKU DKR2F-K: 00-00-E3
Category HDD
Changed Part DKU micro-program

5 Remaining write pending after I/O stop


Phenomena After I/O stopped, the write pending rate did not become 0.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs with all the following conditions met.
1. True Copy for z/OS Sync pair in Duplex or Pending Duplex
2. Execute write to multiple tracks
Affected Products/Version DKCMAIN: 50-03-09-00/00 and higher
Fixed Product/Version DKCMAIN: 50-09-12-00/00
Category True Copy for z/OS
Changed Part DKCMAIN

HDS Confidential 2 of 3
6 UR pair Suspend due to link down for 180 sec. (EC=c828)
Phenomena When a permanent failure (unable to communicate more than 3
minutes) occurred on the line between the main and remote site of
UR, the UR pair suspended despite system option 449 ON, which
is used to prevent link down from being monitored.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs with all the following conditions met.
1. The system option 449, used to prevent link down from being
monitored, is ON
2. UR is in the Copy or Pair state
3. A permanent failure (unable to communicate more than 3
minutes) occurs on the line between the main and remote site of
Universal Replicator
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-09-12-00/00
Category Universal Replicator/ Universal Replicator for z/OS
Changed Part DKCMAIN

7 Performance degradation of PPRC and XRC pair


Phenomena When comparing the performance between in PPRC configuration
and in PPRC and XRC configuration, the response time in the
former configuration significantly degraded. This is because the
increase of Discount Time directly affected the performance.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when the P-VOL of True Copy for z/OS Sync
and the P-VOL of XRC share the same volume.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-09-12-00/00
Category True Copy for z/OS, XRC
Changed Part DKCMAIN

8 WCHK1 at Reserve VOL setting


Phenomena When setting Reserve VOL of Shadow Image or Shadow Image
for z/OS, WCHK1 occurred.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur with the following conditions #1 and #2,
or #1 and #3 met.
1. Set Reserve VOL of Shadow Image or Shadow Image for z/OS
2. MP synchronizing delay
3. MP synchronizing failure
#2 or #3 may more likely occur when changing the configuration
Affected Products/Version DKCMAIN: 50-03-08-00/00 and higher
Fixed Product/Version DKCMAIN: 50-09-12-00/00
Category Shadow Image for Open or z/OS
Changed Part DKCMAIN

HDS Confidential 3 of 3

Anda mungkin juga menyukai