Required technical specifications

Engine Diesel - 4 cylinder, 4 stroke

Gear box 5+1 manual

Emissions norms Compliant with bharat stage- III

Capacity cc 1900 – 3500

Maximum power in hp 70 -100

Minimum torque in nm 190

Wheel base in mm Minimum of 3200

Body dimensions :-

Overall length in mm 4500 -5415

Overall width in mm 1900 – 2100

Overall height in mm 2400 – 2800

Ground clearance in mm 160 – 210

Patient compartment dimensions

Length in mm Minimum of 2755

Height in mm Minimum of 1800

Width in mm Minimum of 1650

All tyres Cross ply / Radial

Electrical system 1 nos, 12 v batteries, 75Ah or above

Alternator 60 amps
Fuel tank capacity Adequate for traveling 300 kms without refueling

Payload capacity Minimum of 1100 kgs

Vehicle exterior specifications

Doors Shall be dual hinged doors with 180 degree open


out at the rear, with glass view panels

Windows Windows: Full Sliding windows/ combination of


fixing & sliding aluminium frame / tiltable on both
sides
Seating in driver compartment Seating in driver compartment : One bucket seat for
driver, and a bench type seat.

Accessories Spare wheel, vehicle tool kit, etc

Vehicle standard items Should be as per the ARAI standards.

Standard Equipment/Accessories

1. The patient compartment and driver’s cabin should be separated.

2. Stretcher ordinary

3. Medicine cabinet

4. Oxygen cylinder cage with cylinder (ISI), flow meter (ISI), humidifier (ISI) and one
set of mask and tubing for adult and paediatric, located suitably to give oxygen to
the patients. Explosive certificate for Oxygen cylinder to be provided. The cylinder
has to be provided in completely filled condition.

5. IV hook on the top roof on at least 3 locations

6. The Light bar should be Rhombus shaped, Double layered structure, Combination of
continually lit, turning lamps and flash lights, High quality tungsten bulbs and xenon
lamp tubes, Long life span, high luminance, Voltage: DC 12V, with integrated Public
addressing systems of 100W. Should have unique high intensity Siren with revolving
flashers and lights indicating emergency while transferring a serious patient. Siren
should have five different tones that can be interchanged in order to draw attention
of public and take way in high density traffic. The control panel for this system
should be fixed at a suitable location in the driver compartment.

7. Doctors seat

8. Squad bench for patient attenders for at least 3 persons

9. Electric fan -2 nos on both sides. (If air-conditioner is provided as standard in the
offered ambulance then fans are not required.

10. Exterior design / painting. All vinyl / reflective stickers/ retro reflective stickers/films to
be used. After finishing the sticker works as per the design provided by the Tender
Inviting Authority has to be laminated or coated with suitable transparent paint.
Detailed drawing and details will be furnished at the time of issue of LOI or Supply
order.