Anda di halaman 1dari 60

GRUNDFOS A WIDE RANGE

50 Hz

GRUNDFOS

A WIDE RANGE
A global business

With more than 18,500 employees and an annual Research and development
production of some 16 million pump units a year, Grundfos In order to maintain the leading position, Grundfos
is one of the world's leading pump manufacturers. Across constantly focuses on customer-oriented research and
all continents, 80 companies in 55 countries help to bring development; customers are consulted when new
pumps to every corner of the world, from supplying products are developed or when established products are
drinking water to Antarctic expeditions, irrigation of Dutch improved.
tulips, groundwater monitoring beneath waste heaps in Research and development make use of the latest
Germany, to air-conditioning in Egyptian hotels. technology within the pump industry, collaborating with
universities and higher education institutions in search of
Efficient, sustainable products new and better solutions for the design and function of the
Grundfos is constantly striving to make its products more products.
user-friendly and reliable - and also more energy-saving
and efficient so both users and the environment benefit Corporate values
from the improvements. The Grundfos Group is based on values such as
Grundfos pumps are equipped with ultramodern sustainability, openness, trustworthiness, responsibility,
electronics, allowing them to regulate the output according and also on partnership with clients, suppliers and the
to current needs. This ensures convenience for the user, society around us, with a focus on humanity that concerns
as well as saves a lot of energy. our own employees as well as the many millions who
benefit from water that is procured, utilised and removed
as wastewater with the help of Grundfos pumps.

3
Efficient pump solutions for all purposes
No matter for which purpose an efficient and energy-saving pump solution is required, Grundfos
offers a high-quality solution.

Heating Air-conditioning Pressure boosting Groundwater supply Domestic water


supply
Circulator pumps for Circulator pumps for Vertical and horizontal, Submersible pumps for Submersible pumps, jet
circulation of water in circulation of cold water centrifugal pumps and groundwater supply, pumps, multistage
central and district and other liquids in pressure boosting irrigation and centrifugal pumps and
heating systems and cooling and air- systems for liquid groundwater lowering. compact systems for
circulation in domestic conditioning systems. transfer and boosting of water supply in homes,
hot water service hot and cold water. gardens and hobby
systems. applications.

4
Wastewater Industrial Dosing and Solar water solutions Motors
applications disinfection
Drainage, effluent and Pumps and pump Dosing pumps for Solar -or wind-powered Motors designed to
sewage pumps for a systems for installation chemical injection in all water pumping systems international standards
wide range of in industrial processes, kinds of water and and components. as well as submersible
applications in building industrial equipment wastewater treatment motors.
services as well as and building utilities. systems and industrial
transfer of raw sewage processes.
in municipal sewage
systems.

5
6
Heating Pressure boosting
ALPHA1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 BM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
ALPHA1L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 BMhp, BMShp. . . . . . . . . . . . . . . . . . . . . . . . . . . 36
ALPHA2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 BMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
ALPHA3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 BMShs, BMST, BMSX. . . . . . . . . . . . . . . . . . . . . . . 35
Grundfos COMFORT, PM. . . . . . . . . . . . . . . . . . . . . 12 CM, CME, CMV . . . . . . . . . . . . . . . . . . . . . . . . . . 29
MAGNA1 model C . . . . . . . . . . . . . . . . . . . . . . . . 15 CMB PM1, CMB-SP PM1, CMB PM2, CMB-SP PM2 . . . . . . 30
MAGNA3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 CMB PT, CMB PS . . . . . . . . . . . . . . . . . . . . . . . . . 30
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 CMBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
NBE, NBGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 CMBE TWIN . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
NBE, NKE series 2000 . . . . . . . . . . . . . . . . . . . . . . 18 CR, CRI, CRN. . . . . . . . . . . . . . . . . . . . . . . . . . . 31
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 CR, CRN high pressure . . . . . . . . . . . . . . . . . . . . . . 32
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . . . . . . . 32
NKE, NKGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
TP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
HS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
TPE series 1000 . . . . . . . . . . . . . . . . . . . . . . . . . 17
Hydro MPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
TPE series 2000 . . . . . . . . . . . . . . . . . . . . . . . . . 16
Hydro Multi-B . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
TPE2, TPE2 D . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Hydro Multi-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
TPE3, TPE3 D . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Hydro Multi-S . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
UP, UPS series 100 . . . . . . . . . . . . . . . . . . . . . . . . 12 Hydro Solo-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
UPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 MTR, MTH, SPK . . . . . . . . . . . . . . . . . . . . . . . . . 20
UPS series 200 . . . . . . . . . . . . . . . . . . . . . . . . . . 15 MTRE, SPKE . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
UPS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
NBE, NBGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NKE, NKGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
SCALA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
TPE series 1000 . . . . . . . . . . . . . . . . . . . . . . . . . 17
UPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Air-conditioning
ALPHA1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ALPHA1L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ALPHA2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
ALPHA3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
CM, CME, CMV . . . . . . . . . . . . . . . . . . . . . . . . . . 29
CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Groundwater supply
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . . . . . . . 32 SP A, SP, SP-G . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Grundfos COMFORT, PM. . . . . . . . . . . . . . . . . . . . . 12 SQ, SQE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
HS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 SQFlex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
MAGNA1 model C . . . . . . . . . . . . . . . . . . . . . . . . 15
MAGNA3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
NBE, NBGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NBE, NKE series 2000 . . . . . . . . . . . . . . . . . . . . . . 18
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NKE, NKGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
TP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
TPE series 1000 . . . . . . . . . . . . . . . . . . . . . . . . . 17
TPE series 2000 . . . . . . . . . . . . . . . . . . . . . . . . . 16
TPE2, TPE2 D . . . . . . . . . . . . . . . . . . . . . . . . . . 17
TPE3, TPE3 D . . . . . . . . . . . . . . . . . . . . . . . . . . 16
UP, UPS series 100 . . . . . . . . . . . . . . . . . . . . . . . . 12
UPS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
UPS series 200 . . . . . . . . . . . . . . . . . . . . . . . . . . 15

7
Domestic water supply Industrial applications
CM, CME, CMV . . . . . . . . . . . . . . . . . . . . . . . . . . 29 AMD, AMGEx, AFGEx . . . . . . . . . . . . . . . . . . . . . . 45
CMB PM1, CMB-SP PM1, CMB PM2, CMB-SP PM2 . . . . . . 30 BM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
CMB PT, CMB PS. . . . . . . . . . . . . . . . . . . . . . . . . 30 BMhp, BMShp. . . . . . . . . . . . . . . . . . . . . . . . . . . 36
CMBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 BMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
CMBE TWIN . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 BMShs, BMST, BMSX. . . . . . . . . . . . . . . . . . . . . . . 35
CR DW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 CM, CME, CMV . . . . . . . . . . . . . . . . . . . . . . . . . . 29
CR, CRI, CRN . . . . . . . . . . . . . . . . . . . . . . . . . . 31 CMB PM1, CMB-SP PM1, CMB PM2, CMB-SP PM2 . . . . . . 30
CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . . . . . . . 32 CMB PT, CMB PS . . . . . . . . . . . . . . . . . . . . . . . . . 30
Hydro MPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 CMBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Hydro Multi-B . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 CMBE TWIN . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Hydro Multi-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 CR, CRI, CRN. . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Hydro Multi-S . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 CRE, CRIE, CRNE . . . . . . . . . . . . . . . . . . . . . . . . 32
Hydro Solo-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 CRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
JP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 DP, EF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
JP Booster with pressure tank . . . . . . . . . . . . . . . . . . 39 DynaFilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
JPC, JPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Hydro MPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
JPC PT, JPA PT, JPD PT . . . . . . . . . . . . . . . . . . . . . 40 Hydro Multi-B . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
SCALA2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Hydro Multi-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Rainwater control . . . . . . . . . . . . . . . . . . . . . . . . . 31 Hydro Multi-S . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
RCME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Hydro Solo-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
RMQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 MTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
SB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 MTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
SBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 MTR, MTH, SPK . . . . . . . . . . . . . . . . . . . . . . . . . 20
SP A, SP, SP-G . . . . . . . . . . . . . . . . . . . . . . . . . . 36 MTRE, SPKE . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
SQ, SQE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 MTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
NBE, NBGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
NKE, NKGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
S pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
SE, SL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
SMD, SMG, SFG . . . . . . . . . . . . . . . . . . . . . . . . . 45
Wastewater SRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
AMD, AMGEx, AFGEx . . . . . . . . . . . . . . . . . . . . . . 45
CONLIFT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
DP, EF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
DPK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
DWK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
KPL, KPG, KWM . . . . . . . . . . . . . . . . . . . . . . . . . 43
LC, LCD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
LIFTAWAY B and C . . . . . . . . . . . . . . . . . . . . . . . . 48
MULTILIFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
PS.G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
PS.R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
PS.W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
S pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
SEG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
SE, SL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
SMD, SMG, SFG . . . . . . . . . . . . . . . . . . . . . . . . . 45
SOLOLIFT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
UNOLIFT/DUOLIFT. . . . . . . . . . . . . . . . . . . . . . . . 47
UNILIFT, KPC . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

8
Dosing and disinfection Motors, controls and accessories
AQpure UF . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Accessories for dosing pumps and systems . . . . . . . . . . . 24
AQtap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 CIM, CIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Conex® DIA-G, DIS-G . . . . . . . . . . . . . . . . . . . . . . 25 Control MPC . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
DIT-M, DIT-L, DIT-IR . . . . . . . . . . . . . . . . . . . . . . . 25 Control MPC series 2000 . . . . . . . . . . . . . . . . . . . . . 51
DME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 CU 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
DMH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 CU 200, CIU 273, IO50, IO101, IO102 . . . . . . . . . . . . . . 38
DMX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 CUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
DTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Control DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
MobileDos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Control DDD. . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Oxiperm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 DID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Oxiperm Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 DPI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Polydos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 DPI V.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Selcoperm SES 125-2000 . . . . . . . . . . . . . . . . . . . . 26 Grundfos GO Remote . . . . . . . . . . . . . . . . . . . . . . . 52
Selcoperm SES 5000-45000 . . . . . . . . . . . . . . . . . . . 26 GT Pressure tanks . . . . . . . . . . . . . . . . . . . . . . . . 55
SMART Digital S DDA . . . . . . . . . . . . . . . . . . . . . . 21 LC, LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
SMART Digital S DDC . . . . . . . . . . . . . . . . . . . . . . 22 LiqTec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
SMART Digital S DDE . . . . . . . . . . . . . . . . . . . . . . 22 MMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
SMART Digital XL DDA . . . . . . . . . . . . . . . . . . . . . . 22 MP 204, CU 300, CU 301, IO 113, SM 113 . . . . . . . . . . . . 51
SMART Digital XL DDE . . . . . . . . . . . . . . . . . . . . . . 23 MS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Vaccuperm . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 PM Rain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
PM1, PM2 pressure managers . . . . . . . . . . . . . . . . . . 55
JP Booster with pressure tank . . . . . . . . . . . . . . . . . . 39
Rainwater control . . . . . . . . . . . . . . . . . . . . . . . . . 31
RPI, RPI+T . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
RPS, DPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
VFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
VFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Solar water solutions
ALPHA SOLAR . . . . . . . . . . . . . . . . . . . . . . . . . . 14
AQpure UF . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
AQtap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
MAGNA1 model C . . . . . . . . . . . . . . . . . . . . . . . . 15
MGFlex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
RSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Solar modules. . . . . . . . . . . . . . . . . . . . . . . . . . . 38
SQFlex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Fire systems
Fire DNF, Fire HSEF . . . . . . . . . . . . . . . . . . . . . . . 19
NB, NBG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
NK, NKG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

9
Products A-Z
Accessories for dosing pumps and systems . . . . . . . . . . . 24 CU 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
AFG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 CU 200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
ALPHA1L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 CU 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
ALPHA1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 CU 301 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
ALPHA2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 CUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
ALPHA3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 DID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
ALPHA SOLAR . . . . . . . . . . . . . . . . . . . . . . . . . . 14 DIT-IR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
AMD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 DIT-L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
AMGAMD, AMGEx, AFGEx . . . . . . . . . . . . . . . . . . . 45 DIT-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
AQpure UF . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 DME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
AQtap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 DMH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
BM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DMX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
BMhp, BMShp . . . . . . . . . . . . . . . . . . . . . . . . . . 36 DP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
BMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DPI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
BMS hp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 DPI V.2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
BMS hs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DPK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
BMST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
BMSX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 DTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
CIM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 DUOLIFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
CIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 DWK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
CIU 273 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 DynaFilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
CM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 EF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
CMB, PM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Fire DNF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CMB, PM2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Fire HSEF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CMB-SP PM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Grundfos COMFORT, PM . . . . . . . . . . . . . . . . . . . . . 12
CMB-SP PM2 . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Grundfos GO Remote . . . . . . . . . . . . . . . . . . . . . . . 52
CMB, PS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 GT Pressure tanks . . . . . . . . . . . . . . . . . . . . . . . . 55
CMB, PT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 HS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CMBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Hydro MPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
CMBE TWIN . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Hydro Multi-B . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
CME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Hydro Multi-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
CMV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Hydro Multi-S . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Conex® DIA-G . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Hydro Solo-E . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Conex® DIS-G . . . . . . . . . . . . . . . . . . . . . . . . . . 25 IO50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
CONLIFT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 IO101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Control DC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 IO102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Control DDD . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 IO 113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Control MPC . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 JP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Control MPC series 2000 . . . . . . . . . . . . . . . . . . . . . 51 JP Booster with pressure tank . . . . . . . . . . . . . . . . . . 39
CR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 JPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
CR DW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 JPA PT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
CR high pressure . . . . . . . . . . . . . . . . . . . . . . . . . 32 JPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
CRE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 JPC PT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
CRI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 JPD PT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
CRIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 KP Basic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
CRN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 KPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
CRN high pressure . . . . . . . . . . . . . . . . . . . . . . . . 32 KPG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
CRNE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 KPL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
CRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 KWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

10
LC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 SBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 SCALA2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
LIFTAWAY B and C . . . . . . . . . . . . . . . . . . . . . . . . 48 SE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
LiqTec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 SEG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
MAGNA1 model C . . . . . . . . . . . . . . . . . . . . . . . . 15 Selcoperm SES 125-2000 . . . . . . . . . . . . . . . . . . . . 26
MAGNA3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Selcoperm SES 5000-45000 . . . . . . . . . . . . . . . . . . . 26
MGFlex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 SFG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
MMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 SL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
MobileDos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 SM 113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
MP 204 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 SMART Digital S DDA. . . . . . . . . . . . . . . . . . . . . . . 21
MQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 SMART Digital S DDC . . . . . . . . . . . . . . . . . . . . . . 22
MS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 SMART Digital S DDE. . . . . . . . . . . . . . . . . . . . . . . 22
MTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SMART Digital XL DDA . . . . . . . . . . . . . . . . . . . . . . 22
MTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 SMART Digital XL DDE . . . . . . . . . . . . . . . . . . . . . . 23
MTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
MTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SMG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
MTRE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Solar modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
MTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 SOLOLIFT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
MULTILIFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 SP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
NB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 SP A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
NBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 SP-G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
NBG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 SP-NE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
NBGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 SPK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
NK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 SPKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
NKE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 SQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
NKE series 2000 . . . . . . . . . . . . . . . . . . . . . . . . . 19 SQE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
NKG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 SQE-NE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
NKGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 SQFlex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
NS, PF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 SRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Oxiperm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 TP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Oxiperm Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 TPE series 1000 . . . . . . . . . . . . . . . . . . . . . . . . . 17
Polydos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 TPE series 2000 . . . . . . . . . . . . . . . . . . . . . . . . . 16
PM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 TPE2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
PM2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 TPE2 D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
PM Rain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 TPE3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
PS.G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 TPE3 D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
PS.R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 UNILIFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
PS.W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 UNOLIFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Rainwater control . . . . . . . . . . . . . . . . . . . . . . . . . 31 UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
RCME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 UPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
RMQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
RPI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 UPS series 100 . . . . . . . . . . . . . . . . . . . . . . . . . . 13
RPI+T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 UPS series 200 . . . . . . . . . . . . . . . . . . . . . . . . . . 15
RPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 UPS2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
RSI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Vaccuperm . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
S pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 VFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
SB. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 VFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

11
UP, UPS series 100 Grundfos COMFORT, PM UPA

Circulator pumps Circulator pumps Circulator pumps for pressure boosting in


domestic applications

H [m] H [m] H [m]


10.0 1.2 15
6.0 0.8 10
4.0 0.6 6
2.0 0.4 4
1.0
0.6 0.2 2
0.4
0.2 0.1 1
0.4 1 2 4 6 10 15 0.1 0.2 0.3 0.4 0.5 0.6 0.5 0.6 0.8 1 1.5 2 2.5
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 9.5 m3/h Flow rate: max. 0.5 m3/h Flow rate: max. 2.2 m3/h
Head: max. 12 m Head: max. 1.2 m Head: max. 12 m
Liquid temperature: -25 to +110 °C Liquid temperature: 2 to 95 °C Liquid temperature: 2 to 95 °C
Operating pressure: max. 10 bar Operating pressure: max. 10 bar Operating pressure: max. 10 bar

Applications Applications Applications


• Heating systems • Domestic hot-water systems in single- and • Pressure boosting of hot and cold drinking
• Domestic hot-water systems two-family houses water in residential homes.
• Cooling and air-conditioning systems. • Small heating systems
• Cooling and air-conditioning systems. Features and benefits
Features and benefits • Flexibility: suitable for installation in existing
• Maintenance-free Features and benefits systems
• Low noise level • Maintenance-free • Comfort: low-noise operation
• Low energy consumption • Low noise level • User-friendly: plug and play
• Wide range. • Low energy consumption down to 2.5 W • Reliability: renowned Grundfos quality
• Wide range • Patented integrated flow switch.
Options • Integrated dry-running protection
• 24-hour timer • Pump head fits on almost all competitor
• Corrosion-resistant stainless-steel pump pump housings.
housing.
Options
• 24-hour timer
• Corrosion-resistant stainless-steel pump
housing
• Adapting to the user pattern, AUTOADAPT
variant
• 3-speed variant available
• Adjustable thermostat.

12
UPS2 ALPHA1L ALPHA1

Circulator pumps Circulator pumps Circulator pumps

H [m] H [m] H [m]


8 8
8
6 6
6 5 5
4 4
4
3 3

2 2 2

1 1 1
0.5 1 2 3 4 5 6 0 1 1.5 2 3 4 0.5 1 1.5 2 3 4
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 5.8 m3/h Flow rate: max. 3.6 m3/h Flow rate: max. 3.9 m3/h
Head: max. 8 m Head: max. 6 m Head: max. 8 m
Liquid temperature: 2 to 95 °C Liquid temperature: 2 to 95 °C Liquid temperature: 2 to 110 °C
Operating pressure: max. 10 bar Operating pressure: max. 10 bar Operating pressure: max. 10 bar

Applications Applications Applications


• Heating systems • Heating systems • Heating systems
• Cooling and air-conditioning systems. • Domestic hot-water systems • Domestic hot-water systems
• Cooling and air-conditioning systems. • Cooling and air-conditioning systems.
Features and benefits
• Low energy consumption Features and benefits Features and benefits
• Maintenance-free • Three constant curves/constant speed • Low energy consumption
• Low noise level curves • Maintenance-free
• Wide range • Radiator heating mode • Low noise level
• Simple installation • Underfloor heating mode • Wide range
• 3-speed proportional-pressure control • PWM Input, A profile, External pump • Display of actual power consumption
• 3-speed constant-curve control. control. The PWM signal is a method for • Simple installation, external plug for
generating an analog signal using a digital electrical connection
source • 3-speed proportional-pressure control
• Energy Efficiency Index (EEI) ≤ 0.20, below • 3-speed constant-pressure control
ErP 2015 requirements • 3-speed constant-curve control
• Deblocking screw • Automatic deblocking.
• Maintenance-free
• Low noise level Options
• Very simple installation. • Wetted parts in stainless steel.

Options
• Wetted parts in stainless steel.

13
ALPHA2 ALPHA3 ALPHA SOLAR

Circulator pumps Circulator pumps Circulator pumps

H [m] H [m]
8 8
6 6
5 5
4 4
3 3

2 2

1 1
0.5 1 1.5 2 3 4 0.5 1 1.5 2 3 4
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 3.9 m3/h Flow rate: max. 3.9 m3/h Flow rate: max. 3.2 m3/h
Head: max. 8 m Head: max. 8 m Head: max. 14.5 m
Liquid temperature: 2 to 110 °C Liquid temperature: 2 to 110 °C Liquid temperature: 2 to 130 °C
Operating pressure: max. 10 bar Operating pressure: max. 10 bar Operating pressure: max. 10 bar

Applications Applications Applications


• Heating systems • Heating systems • Solar systems
• Domestic hot-water systems • Cooling and air-conditioning systems.
• Cooling and air-conditioning systems. Features and benefits
Features and benefits • Constant speed
Features and benefits • Best Energy Efficiency Index, EEI, value in • PWM C profile. The PWM signal is a
• Best Energy Efficiency Index, EEI, value in class method for generating an analog signal
class • ALPHA3 is completely controlled with using a digital source
• Multiple automatic control modes Grundfos GO Remote via Bluetooth • Low Energy Efficiency Index, EEI
• AUTOADAPT • Radiator and underfloor heating modes • Maintenance-free
• Display of actual power consumption with AUTOADAPT
• Low noise level
• Display of actual flow rate • Multiple automatic control modes with
• Very simple installation.
• Automatic night setback setpoint adjustment
• Maintenance-free • Display of actual power consumption
• Low noise level • Display of actual flow
• Very simple installation • Maintenance-free
• Manual summer mode • Low noise level
• Dry-running protection • Very simple installation
• Automatic deblocking • Dry-running protection
• Support for balancing for radiators and • Automatic deblocking
underfloor heating system. • Support for balancing for radiators and
underfloor heating system.
Options
• Air separator
• Wetted parts in stainless steel.

14
UPS series 200 MAGNA1 model C MAGNA3

Circulator pumps Circulator pumps, electronically controlled Circulator pumps, electronically controlled

H [m] H [m] H [m]


20 18 18
14 14
10 10 10
6
4 6 6
4 4
2

1 2 2
2 4 6 8 10 20 40 60 80 2 4 6 10 20 40 60 120 2 4 6 10 20 40 80 150
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 70 m3/h Flow rate: max. 110 m3/h Flow rate: max. 150 m3/h
Head: max. 18 m Head: max. 18 m Head: max. 18 m
Liquid temperature: -10 to +120 °C Liquid temperature: -10 to +110 °C Liquid temperature: -10 to +110 °C
Operating pressure: max. 10 bar Operating pressure: max. 16 bar Operating pressure: max. 16 bar

Applications
Applications Applications
• Heating systems
• Heating systems • Heating systems
• Hot-water recirculation systems
• Domestic hot-water systems • Hot-water recirculation systems • Cooling and air-conditioning systems
• Cooling and air-conditioning systems. • Cooling and air-conditioning systems
• Geothermal and solar systems.
• Geothermal and solar systems.
Features and benefits Features and benefits
• Maintenance-free Features and benefits • Low energy consumption: MAGNA3 pumps
• Built-in thermal switch • With best-in-class EEI of ≤ 0.20 on single are best in class with an impressive EEI of
• Low noise level pumps. All new MAGNA 1 pumps are highly ≤ 18 on single pumps
• Low energy consumption energy efficient. • The application wizard supports the
• Single-phase with built-in protection • Backwards compatible with MAGNA1 commissioning scenario by automatically
module • Digital input (start/stop) selecting the correct setup based on the
• Wide range. • Fault relay • Operating log
• Grundfos GO Remote support for fault • Heat energy monitor
Options remedy • Wireless multipump function with time-
• Protection module • Wireless multipump function with time- based alternation
• Relay module with fault signal or operating based alternation • External setpoint functions
output • Differential-temperature control.
• Bronze pump housing Options
Options
• Twin-head versions. • PN16 variants
• Insulating shells for cooling. • CIM modules available for various BMS
protocols
• Stainless-steel pump housing
• Twin-head versions
• Wireless remote control by means of
Grundfos GO Remote
• PN16 variants
• Insulating shells for cooling.

15
TP TPE series 2000 TPE3, TPE3 D

In-line circulator pumps, close-coupled type In-line circulator pumps, electronically In-line circulator pumps, electronically
controlled controlled

H [m] H [m] H [m]


200 100 25
100 20
40 15
50
20
10
20 10 8
10 4 6

5 2 4
10 40 100200400 1000 4000 2 5 10 20 50 200 1000 5 10 20 30 40 60 100
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 4,600 m3/h Flow rate: max. 340 m3/h Flow rate: max. 120 m3/h
Head: max. 140 m Head: max. 92 m Head: max. 25 m
Liquid temperature: -25 to +150 °C Liquid temperature: -25 to +140 °C Liquid temperature: -25 to +120 °C
Operating pressure: max. 25 bar Operating pressure: max. 16 bar Operating pressure: max. 16 bar

Applications Applications Applications


• Heating systems • Heating systems • Heating and cooling systems
• District heating plants • Domestic hot-water systems • District heating plants
• Local heating plants • Cooling and air-conditioning systems. • Hot-water recirculation.
• Hot-water recirculation
• Cooling and air-conditioning systems Features and benefits Features and benefits
• District cooling plants • Low energy consumption • Low energy consumption
• Water supply systems. • Adaptation to existing operating conditions • Simple installation
• Simple installation • TFT colour display
Features and benefits • Factory-fitted differential-pressure sensor • Factory-fitted differential-pressure and
• Compact design with small footprint • Fitted with motors equivalent to IE3 (IE4 up temperature sensor
• Wide range to 11 kW). • AUTOADAPT, FLOWLIMIT, FLOWADAPT
• Standard IE3 motor • Differential-temperature or differential-
• Service-friendly, top pull-up design Options pressure control with two sensors
• Various types of shaft seals depending on • Wireless remote control by means of • Fitted with IE5 motor
liquid, temperature and pressure. Grundfos GO Remote • Compact design with small footprint.
• Communication via GENIbus, LONWorks,
Options PROFIBUS DP, Modbus RTU, 3G/4G Options
• Bronze or stainless steel pump housing cellular, GRM GiC 3G/4G, BACnet MS/TP, • Wireless remote control by means of
• Bronze impeller PROFINET, Modbus TCP, BACnet IP, Grundfos GO Remote
• Stainless-steel impeller EtherNet/IP, GRM IP • Communication via GENIbus, LONWorks,
• Twin-head versions • Twin-head versions with built-in alternation PROFIBUS DP, Modbus RTU, 3G/4G
• IE4 motor up to 45 kW. and standby function. cellular, GRM GiC 3G/4G, BACnet MS/TP,
PROFINET, Modbus TCP, BACnet IP,
EtherNet/IP, GRM IP.

16
TPE series 1000 TPE2, TPE2 D NB, NBG

In-line circulator pumps - electronically In-line circulator pumps - electronically Single-stage standard pumps
controlled controlled

H [m] H [m] H [m]


100 25 200
20
40 100
15
20 50
10
10 8 20
4 6
10
2 4 6
2 5 10 20 50 200 1000 5 10 20 30 40 60 100 4 10 20 50 200 500 2000
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 340 m3/h Flow rate: max. 120 m3/h Flow rate: max. 2300 m3/h
Head: max. 92 m Head: max. 25 m Head: max. 200 m
Liquid temperature: -25 to +150 °C Liquid temperature: -25 to +120 °C Liquid temperature: -25 to +140 °C
Operating pressure: max. 25 bar Operating pressure: max. 16 bar Operating pressure: max. 25 bar

Applications Applications Applications


• Heating systems • Heating and cooling systems • District heating plants
• District heating plants • District heating plants • Heating systems for blocks of flats
• Local heating plants • Hot-water recirculation. • Air-conditioning systems
• Hot-water recirculation • Cooling systems
• Cooling and air-conditioning systems Features and benefits • Washdown systems
• District cooling plants • Low energy consumption • Firefighting systems
• Water supply systems. • Simple installation • Other industrial systems.
• Differential-temperature or differential-
Features and benefits pressure control with 2 sensors Features and benefits
• Low energy consumption • Three possibilities of setpoint influence • Standard dimensions according to EN and
• Adaptation to existing operating conditions • Limit-exceeded function ISO standards
• Many control facilities • Fitted with IE5 motor • Compact design
• Fitted with IE5 motors up to 11 kW • Compact design with small footprint. • Flexible pump range
• Compact design with small footprint. • Standard motor
Options • EN 12756 shaft seal.
Options • Wireless remote control by means of
• Wireless remote control by means of Grundfos GO Remote
Grundfos GO Remote • Communication via GENIbus, LONWorks,
• Communication via GENIbus, LONWorks, PROFIBUS DP, Modbus RTU, 3G/4G
PROFIBUS DP, Modbus RTU, 3G/4G cellular, GRM GiC 3G/4G, BACnet MS/TP,
cellular, GRM GiC 3G/4G, BACnet MS/TP, PROFINET, Modbus TCP, BACnet IP,
PROFINET, Modbus TCP, BACnet IP, EtherNet/IP, GRM IPTwin-head versions
EtherNet/IP, GRM IP with built-in alternation, standby and
• Twin-head versions with built-in alternation cascade function.
and standby function.

17
NBE, NBGE NBE, NKE series 2000 NK, NKG

Single-stage standard pumps - electronically Single-stage standard pumps according to Single-stage standard pumps according to
controlled EN 733 and ISO 5199, electronically EN 733, ISO 2858 and ISO 5199
controlled
H [m] H [m] H [m]
80 300
100 200
60 50
100
40 30
20 50
20
10 20
10
6 6 10
4 4 6
4 10 20 50 100 200 500 4 10 20 50 100 200 500 4 10 20 50 100 200 500 1000
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 420 m3/h Flow rate: max. 550 m3/h Flow rate: max. 2300 m3/h
Head: max. 90 m Head: max. 80 m Head: max. 230 m
Liquid temperature: -25 to +140 °C Liquid temperature: -25 to +140 °C Liquid temperature: -25 to +140 (+200)
Operating pressure: max. 25 bar Operating pressure: max. 10 bar °C
Operating pressure: max. 25 bar
Applications Applications
• District heating plants • Heating systems Applications
• Heating systems for blocks of flats • Hot-water recirculation • District heating plants
• Air-conditioning systems • Cooling and air-conditioning systems. • Water supply systems
• Cooling systems • Air-conditioning systems
• Washdown systems Features and benefits • Cooling systems
• Other industrial systems. • Low energy consumption • Washdown systems
• Adaptation to existing operating conditions • Firefighting systems
Features and benefits • Simple installation • Other industrial systems.
• Standard dimensions according to EN and • Factory-fitted differential-pressure sensor
ISO standards • Fitted with IE5 motors up to 11 kW. Features and benefits
• Compact design • Standard dimensions according to EN and
• Flexible pump range Options ISO standards
• EN 12756 shaft seal. • Wireless remote control by means of • Robust design
Grundfos GO Remote • Standard motor
Options • Communication via GENIbus, LONWorks, • EN 12756 shaft seal.
• Wireless remote control by means of PROFIBUS DP, Modbus RTU, 3G/4G
Grundfos GO Remote cellular, GRM GiC 3G/4G, BACnet MS/TP,
• Communication via GENIbus, LONWorks, PROFINET, Modbus TCP, BACnet IP,
PROFIBUS DP, Modbus RTU, 3G/4G EtherNet/IP, GRM IP.
cellular, GRM GiC 3G/4G, BACnet MS/TP,
PROFINET, Modbus TCP, BACnet IP,
EtherNet/IP, GRM IP.

18
NKE, NKGE HS Fire DNF, Fire HSEF

Single-stage standard pumps according to Horizontal split case pumps Fire pump sets
EN 733, ISO 2858 and ISO 5199 -
electronically controlled
H [m] H [m] H [m]
100 150 150
60 100
100
40 60 80
20 40 60
40
10 20
6
4 10 20
4 10 20 50 100 200 500 20 50 100 200 500 1000 3000 60 100 200 500 1000 2000
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 550 m3/h Flow rate: max. 2,500 m3/h With electric motor
Head: max. 90 m Head: max. 148 m Flow rate: 250-4500 gpm
Liquid temperature: -25 to +140 °C Liquid temperature: -12 to +100 °C Head: max. 182 psi
Operating pressure: max. 25 bar Operating pressure: max. 16 bar
With diesel engine
Applications Applications Flow rate: 250-4000 gpm
• District heating plants • Water supply systems Head: max. 212 psi
• Water supply systems • Air-conditioning systems Liquid temperature: 5 to 40 °C
• Air-conditioning systems • Cooling systems
• Cooling systems • Irrigation systems Applications
• Washdown systems • Other industrial systems • Fire pump sets for firefighting systems.
• Other industrial systems. • District heating systems.
Features and benefits
Features and benefits Features and benefits
• With electric motor or diesel engine
• Standard dimensions according to EN and • Robust between-bearing design • FM-approved and UL-listed
ISO standards • Double suction to reduce axial forces
• Simple installation and easy maintenance
• Robust design • Double volute casing to reduce radial load
• Designed for superior functionality and
• EN 12756 shaft seal. • Removable bearing housing for easy performance reliability.
maintenance
Options • Many variants available
• Wireless remote control by means of • Flange dimensions according to EN 1092-2
Grundfos GO Remote (DIN 2501).
• Communication via GENIbus, LONWorks,
PROFIBUS DP, Modbus RTU, 3G/4G Options
cellular, GRM GiC 3G/4G, BACnet MS/TP, • Cast-iron housing
PROFINET, Modbus TCP, BACnet IP, • Stuffing box
EtherNet/IP, GRM IP. • Stainless-steel impeller.

19
MTR, MTH, SPK MTRE, SPKE MTA

Multistage centrifugal immersible pumps Multistage centrifugal immersible pumps - SIngle-stage coolant pump
electronically controlled

H [m] H [m] H [m]


400 400 15
300 300
200 10
200
150 150 6
100 100
4
60 60
40 40 2

20 20
1 2 4 6 10 20 40 80 1 2 4 6 10 20 40 80 10 20 30 40 60 100 200 400
Q [m³/h] Q [m³/h] Q [l/min]

Technical data Technical data Technical data


Flow rate: max. 85 m3/h Flow rate: max. 85 m3/h Flow rate: max. 355 l/min
Head: max. 238 m Head: max. 380 m Head: max. 13.5 m
Liquid temperature: -10 to +90 °C Liquid temperature: -10 to +90 °C Liquid temperature: 0 to 60 °C
Operating pressure: max. 25 bar Operating pressure: max. 25 bar
Applications
Applications Applications • Machine tools
• Machine tools • Machine tools • Filter and conveyor systems.
• Components washing machines • Components washing machines
• Chiller units • Chiller units Features and benefits
• Industrial washing machines • Industrial washing machines • High-efficiency motor and hydraulic
• Filter and conveyor systems • Filter and conveyor systems • Wide range
• Temperature control • Temperature control • Flexible installation length
• Boiler feed • Boiler feed • Reliability
• General pressure boosting. • General pressure boosting. • No shaft seal
• Semi-open impeller
Features and benefits Features and benefits • Easy installation.
• Flexible installation length • Wide range
• Wide range • Reliability
• Reliability • Service-friendly
• Service-friendly • Simple installation
• Simple installation • Space-saving
• Space-saving • High efficiency
• High efficiency. • Many control facilities.

Options
• Wireless remote control by means of
Grundfos GO Remote.

20
MTS MTB SMART Digital S DDA

High-pressure pumps for tank top installation Single-stage centrifugal end-suction pumps Digital diaphragm dosing pumps
with semi-open impeller

H [m] p [bar]
50 16
40 10
7
20
4

10

5 0
56 10 20 40 60 100 0 1 7.51217 30
Q [m³/h Q [l/h]

Technical data Technical data Technical data


Flow rate: max. 850 l/min Flow rate: max. 90 m3/h Capacity, Q: max. 30 l/h
Head: max. 120 bar Head: max. 47 m Pressure, p: max. 16 bar
Liquid temperature: 0 to 80 °C Liquid temperature: -10 to +90 °C Turn-down ratio: 1:3000 or 1:1000
Operating pressure: max. 130 bar Operating pressure: max. 16 bar Liquid temperature: max. 45 °C

Applications Applications Applications


Pumping of coolants in machine tool • Machine centres High-end solution.
applications, such as: • Coolant systems • Water and wastewater treatment
• deep-hole drilling • Filtration plants • Process water
• grinding • Grinding machines • Food and beverage industry
• cutting. • Parts cleaning systems • Ultrafiltration and reverse osmosis
• Other industrial applications where semi- • Pulp and paper industry.
Features and benefits open impellers are needed.
• High efficiency Features and benefits
• Wear-resistant Features and benefits • Internal stroke-speed and frequency control
• Compact design • Standard dimensions according to EN and • Manual, pulse and 0/4-20 mA control
• Low noise level and pulsation. ISO standards • Batch, timer cycle, timer week control
• Compact design • FlowControl with selective fault diagnosis,
Options • Semi-open impeller and effective solid pressure monitoring
• Dry installation handling • Integrated flow measurement and
• Mechanical shaft seal • Standard IE2 motor. AutoFlowAdapt
• Variety of connections. • 0/4-20 mA and 2 relay outputs
• Auto deaeration
• Power supply 100-240 V, 50/60 Hz.

Options
• E-box for PROFIBUS, Ethernet or Modbus.

21
SMART Digital S DDC SMART Digital S DDE SMART Digital XL DDA

Digital diaphragm dosing pumps Digital diaphragm dosing pumps Digital diaphragm dosing pumps

p [bar] p [bar] p [bar]

10
10 10
7
7

4 4 4

0 0
0 1 6 9 15 0 1 6 15 0 10 20 60 120200
Q [l/h] Q [l/h] Q [l/h]

Technical data Technical data Technical data


Capacity, Q: max. 15 l/h Capacity, Q: max. 15 l/h Flow, Q: max. 200 l/h
Pressure, p: max. 10 bar Pressure, p: max. 10 bar Pressure, p: max. 19 bar
Turn-down ratio: 1:1000 Turn-down ratio: 1:1000 Turn-down ratio: 1:800
Liquid temperature: max. 45 °C Liquid temperature: max. 45 °C Liquid temperature: 0 to 50 °C

Applications Applications Applications


Optimum price-performance ratio. Digital Dosing for basic applications. • Drinking-water treatment
• Water and wastewater treatment • Water and wastewater treatment • Wastewater treatment
• Boiler feed water • Swimming pool water • Boiler water treatment
• Swimming pool water • Cooling tower • Cooling water treatment
• Cooling tower • Chemical industry • Process water treatment
• Chemical industry. • Car wash • Chemical industry
• Irrigation. • Ultrafiltration process and reverse osmosis
Features and benefits • Food and beverage industry
• Internal stroke-speed and frequency control Features and benefits • Pulp and paper industry.
with stepper motor • Internal stroke-speed and frequency control
• Flexible control cube and mounting plate with stepper motor Features and benefits
• Click wheel and graphical display • Only two models from 0.006 to 15 l/h • Internal stroke-speed and frequency control
• Capacity setting in ml/h, l/h, or gph • Smooth continuous dosing with powerful PMS (Permanent Magnet
• Manual, pulse and 0/4-20 mA control • Always full stroke length Synchronous) motor
• 2 relay outputs • Flexible mounting plate • Manual, pulse and 0/4-20 mA control
• Smooth dosing of degassing liquids • Capacity adjusting knob • Batch, timer cycle, timer week control
• Slow mode • Manual control (0.1 - 100 %) • FlowControl with selective fault diagnosis,
• Power supply 100-240 V, 50/60 Hz. • Pulse control (1:n) pressure monitoring
• External stop and empty-tank input • Integrated flow measurement and
• Power supply 100-240 V, 50/60 Hz. AutoFlowAdapt
• 0/4-20 mA and 2 relay outputs
• Auto deaeration
• Power supply 100-240 V, 50/60 Hz
• Fieldbus communication with CIM, CIU.

22
SMART Digital XL DDE DME DMX

Digital diaphragm dosing pumps Digital diaphragm dosing pumps Motor-driven diaphragm dosing pumps

p [bar] p [bar] p [bar]


10
10 8
10 6
7

4
4 3

0 0 0
0 10 20 60 120200 376 940 0 190 460 4000
Q [l/h] Q [l/h] Q [l/h]

Technical data Technical data Technical data


Capacity, Q: max. 200 l/h Capacity, Q: max. 940 l/h Capacity, Q: max. 4000 l/h (pump
Pressure, p: max. 19 bar Pressure, p: max. 10 bar with two heads: 2 x
Turn-down radio 1:800 Liquid temperature: max. 50 °C 4000 l/h)
Liquid temperature: 0 to 50 °C Pressure, p: max. 10 bar
Applications Liquid temperature: max. 50 °C
Applications • Water and wastewater treatment
• Drinking-water treatment • Process plants Applications
• Wastewater treatment • Filtration systems • Drinking-water treatment
• Boiler water treatment • Paper production • Wastewater treatment (settlement/sludge
• Cooling water treatment • Food and beverage industry. treatment)
• Process water treatment • Pulp and paper industry
• Chemical industry Features and benefits • Textile industry
• Ultrafiltration process and reverse osmosis • Capacity setting in ml/h or l/h • Industrial water and wastewater treatment
• Food and beverage industry • Internal stroke-speed and frequency control • Cooling tower.
• Pulp and paper industry with brushless DC motor
• Irrigation • Front- or side-fitted operating panel with Features and benefits
• Swimming pool water. display • Robust design
• Operating panel lock • Stroke-length adjustment.
Features and benefits • 4-20 mA control
• Internal stroke-speed and frequency control • Pulse- and timer-based batch control Options
with powerful PMS (Permanent Magnet • Anti-cavitation function • Frequency converter (PROFIBUS,
Synchronous) motor • Easy calibration function PROFINET, 4-20 mA control, alarm signals)
• Smooth continuous dosing • Diaphragm leakage sensor. • Pulse control (control variant AR)
• Always full stroke length • Analog control (control variant AR)
• Flexible control cube Options • Level input from storage tank (control
• Capacity adjusting knob • Fieldbus communication module. variant AR)
• Manual control (0.1 - 100 %) • With ATEX approval (DMX 226).
• Pulse control (1:n)
• 4-20 mA analog control
• External stop and empty-tank input
• Power supply 100-240 V, 50/60 Hz
• Fieldbus communication module.

23
DMH Accessories for dosing DID
pumps and systems
Hydraulic piston diaphragm dosing pump Measurement and control system for up to 3
water quality parameters

p [bar]
Accessories Technical data
200
• Installation kits Available digital sensors:
100
• Tubing • Disinfectants: Cl2 (free or total), ClO2,
50
• Pump connections H2O2 and PAA
16
• Foot valves • PH
10 • Rigid suction lances • ORP
• Outlet lines • Conductivity.
4
• Injection units All sensors include temperature
0 • Pressure-relief valves measurement and internal compensation
0 50 105 276 1500
Q [l/h] • Pressure-loading valves control unit with 3 freely assignable controller
• Multi-function valve functions, alarm and data logger functionality.
Technical data • Pulsation dampers System setup either with bypass flow cell or
• Tanks with holder for immersed installation of the
Capacity, Q: max. 1500 l/h (pump
• Electric mixers sensor(s).
with two heads: 2 x
• Automatic venting valves
1500 l/h)
• Diaphragm leakage sensor Applications
Pressure, p: max. 200 bar
• Dosing monitor Measurement of water parameters and
Liquid temperature: max. 90 °C
• Flowmeter control of dosing equipment in the following
• Water meter applications:
Applications • Cables and plugs. • Drinking-water treatment
• Oil refinery industry
• Industrial water treatment
• Heavy-duty applications
• Pulp, paper and textile industries • Wastewater treatment, only certain
• Cooling tower, power plants parameters
• Industrial water and wastewater treatment. • Swimming pool water treatment.

Features and benefits Features and benefits


• Designed for heavy-duty operation CU 382 control unit:
• Stroke-length adjustment • Data logger functionality
• Long life due to piston diaphragm • Flexible assignment of inputs and outputs
technology • Modbus included
• Full PTFE diaphragm. • Digital sensor interface
• Data interchange with USB stick.
Options Sensors:
• Frequency converter (PROFIBUS, • Reliable digital data transfer to control
PROFINET, 4-20 mA control, alarm signals) unit
• Available with API 675 approval • Onboard storage of calibration data
• Available with ATEX approval • Pre-calibrated sensors for pH, ORP and
• Servo motor for stroke-length adjustment. conductivity.

24
DIT-M, DIT-L, DIT-IR Conex® DIA-G, DIS-G Polydos

Photometer for water analysis and calibration Gas warning systems Preparation systems for dry material and
of measurement systems liquid polymers

Technical data Technical data Technical data


Measuring parameters: Conex® DIA-G: • Capacity range: Up to 10 m3/h of prepared
• DIT-M: aluminium, bromine, chlorine (free, Intelligent, membrane-covered gas sensors solution with 60 minutes maturation time
total, combined), chlorine dioxide, chloride, with integrated RAM for challenging • Concentration range: 0.05 to 0.5 %
chlorite, cyanuric acid, iron, fluoride, measuring tasks. • Water inlet: Shut-off valve, solenoid valve,
manganese, ozone, phosphate, pH, acid pressure-reducing valve and contact water
capacity KS 4.3, hydrogen peroxide Sensor type, production number, meter
• DIT-L: chlorine, chlorine dioxide, chlorite or manufacturing date and slope are stored in • Maximum viscosity of the polymer solution:
ozone as well as the pH value. the memory. Gas warning system for Cl2, 2500 mPas
ClO2, O3 (amperometric and potentiostatic • Ultrasonic sensor for continuous level
Applications probes) and NH3, HCl (potentiostatic probes). control with programmable cut-off points
The compact hand photometers DIT-M and • Flow proportional preparation.
DIT-L are dedicated for routine analysis in Conex® DIS-G:
water treatment monitoring and for calibration Rugged, low-budget gas sensors for dry Applications
of measurement and control systems. rooms. Gas warning system for Cl2, ClO2, O3 Preparation of polymers, lime, activated
• Drinking-water treatment (amperometric probes). carbon, aluminium sulphate, etc. for water,
• Swimming pool water treatment wastewater and sludge treatment.
• Industrial water treatment. Applications
• Gas dosing installations Features and benefits
Features and benefits • Monitoring of gas storage rooms. • Polydos: One-, two- or three-chamber units
• Compact and ergonomic design for handling, preparation and dosing of dry
• High operating convenience Features and benefits and liquid polymers and other material
• DIT-M: Multilingual plain-text operator Capable of monitoring two different gas • Dry and liquid material feeding system
prompting storage rooms or two different gases at the • Fully automatic systems with PLC control.
• DIT-L: Language-neutral user interface same time. • Graphic display with multilingual user
• Interference filters and long-term stable • Simultaneous measurement and display of interface
LEDs without moving parts two measuring parameters • Preparation and ripening chamber with
• Long-term stable reagent tablets. • Optimum safety electric agitators. Optional for the dosing
• Very short response time chamber
Options • Long and maintenance-free sensor service • Contactless ultrasonic level sensor to
• Data transfer to a PC or a printer with life enable flow proportional preparation.
the optional DIT-IR infrared interface • Automatic sensor recognition and auto
module. calibration
• Separate sensor interface for Conex® DIA-
G for each potentiostatic sensor
• Internal CAN bus for the connection of
potentiostatic sensors
• Optional acoustic and visual alarm device.

25
Vaccuperm Selcoperm SES 125-2000 Selcoperm SES 5000-45000

Full-vacuum chlorine gas dosing systems for On-site generation of sodium hypochlorite for On-site generation of sodium hypochlorite for
disinfection disinfection disinfection

Technical data Technical data Technical data


VGB: capacities up to 4 kg/h Capacity: 110-1800 g/h Capacity: 5000-45000 g/h
VGA: capacities up to 10 kg/h Water consumption: 140-170 l per kg of Water consumption: 125 l per kg of
VGS: capacities up to 200 kg/h prepared chlorine prepared chlorine
Salt consumption: 4 to 4.5 kg per kg of Salt consumption: 3 to 3.5 kg per kg of
Applications prepared chlorine prepared chlorine
• Water treatment in municipal waterworks Sodium hypochlorite 0.5 - 0.65 % Sodium hypochlorite 0.8 - 0.85 %
and with independent water suppliers concentration: concentration:
• Treatment of wastewater Power consumption 5.5 to 6.5 kWh per kg Power consumption 5 to 5.4 kWh per kg of
• Treatment of industrial process water and (AC): of prepared chlorine. (AC): prepared chlorine.
water in cooling towers
• Water treatment in public swimming pools Applications Applications
and hotel pools. • Water treatment in municipal waterworks • Water treatment in municipal waterworks
and with independent water suppliers and with independent water suppliers
Features and benefits • Treatment of wastewater • Treatment of wastewater
• Reliable full-vacuum systems • Treatment of industrial process water and • Treatment of industrial process water and
• Approved disinfection method complying water in cooling towers water in cooling towers.
with WHO drinking-water guidelines • Swimming-pool water treatment.
• Systems for direct installation on chlorine Features and benefits
gas cylinders or drums or for installation in Features and benefits • Unique safety concept, meaning that no
header lines • Compact, robust and safe design explosion-proof area is needed inside the
• Fully automated systems (wall- or floor- • Only water, common salt and power are building (conforms with Directive 2014/34/
mounted) needed for the electrolysis method, and EU)
• Precise regulation and dosing of gaseous operating costs are very low • Safe and reliable method of producing
chlorine • Unique safety concept, meaning that no sodium hypochlorite on site
• Simple handling and user-friendly design explosion-proof area is needed inside the • Only water, common salt and power are
• Complete range of accessories available building (conforms with Directive 2014/34/ needed for the electrolysis, and operating
on request: injectors, automatic EU) costs are very low.
changeover units, evaporators, liquid traps • Fresh sodium hypochlorite is always • Fresh sodium hypochlorite is always
and gas-warning system. available and does not dissociate like available and does not dissociate like
commercial sodium hypochlorite solutions commercial sodium hypochlorite solutions
• Simple handling and user-friendly design • Low maintenance and a long service life
• Low maintenance and a long service life due to robust components
due to robust components. • Standardised modular system
• Outstanding performance data.

26
Oxiperm Oxiperm Pro MobileDos

Chlorine dioxide preparation and dosing Compact chlorine dioxide preparation and Portable dosing station
systems for disinfection dosing system for disinfection

Technical data Technical data Technical data


MobileDos is a preassembled, compact and
OCD-164 OCD-162 portable dosing station ready for connection to
• Capacity: up to 2 kg/h Capacity: up to 60 g/h 5-30 litre containers.
• Hypochloric acid/sodium chlorite method Concentration of pre-cursor chemicals: Included components:
with diluted chemicals: HCl: 9 % by weight • System rack
HCl: 9 % by weight NaClO2: 7.5 % by weight. • PE suction lance with jerrican adaptor, low-
NaClO2: 7.5 % by weight. level and empty tank indication
• Mounting plate for a Smart Digital dosing
Applications
OCC-164 pump
• Water treatment in municipal waterworks,
• Capacity: up to 10 kg/h • Pressure relief valve and pressure loading
hotels, hospitals, retirement homes, sports valve
• Hypochloric acid/sodium chlorite method facilities, shower facilities
• Control cable, 5 m
with concentrated chemicals: • Treatment of industrial process water,
HCl: 33 % by weight • Outlet line, 6 m
washing water and cooling circuit water • Injection unit.
NaClO2: 24.5 % by weight. • Disinfection in bottle wash systems, rinsers,
The dosing pump can be selected from the
CIP systems
Smart Digital range up to 30 l/h.
OCG-166 • Disinfection in dairies (condenser vapour,
• Capacity: up to 10 kg/h pasteurisation).
Applications
• Chlorine gas/sodium chlorite method:
• Water and wastewater treatment
NaClO2: 24.5 % by weight Features and benefits
Cl2: 3 g/l. • Washing systems
• Up to 90 % of the operating cost can be • Swimming pools
saved compared to thermal disinfection
• Process plants
ISIA • Compact system to be installed in confined
• Paper production
• Capacity: up to 20 kg/h spaces • Food and beverage industry.
• Hypochloric acid/sodium chlorite method • Ergonomic design. Operation and
with concentrated chemicals: maintenance are performed from the front
Features and benefits
HCl: 31-33 % by weight • On-site preparation of chlorine dioxide
NaClO2: 25 or 31 % by weight. • Optional with chlorine dioxide control • Flexible system for a wide range of
applications and dosing tasks
• Simple assembly and startup. The system
• Suitable for many different chemicals due to
Applications can be connected and put into operation
with limited interruption of the water supply high-quality materials
• Water treatment in municipal waterworks • Minimal installation and commissioning
• Treatment of industrial process water, • Complete chemical reaction within a
effort.
washing water and cooling circuit water minimum of time
• Disinfection in bottle wash systems, rinsers, • Low operating costs and low consumption
CIP systems of chemicals.
• Disinfection in dairies (condenser vapour,
pasteurisation).

Features and benefits


• On-site preparation of chlorine dioxide
• Ergonomic design
• Innovative dosing and calibration
technology
• Complete chemical reaction within a
minimum of time
• Low operating costs and low consumption
of chemicals.

27
DTS AQtap AQpure UF

Dosing tank stations Water dispenser for water kiosks Modular and automated ultrafiltration water
treatment system for drinking water

Technical data Technical data Technical data


A DTS includes a tank and some installation • Hydraulic capacity: 1 m3/h under normal • Water production: up to 2 m3/h
material, and is prepared for one of the operating conditions • Membrane type: hollow fibre, dead-end,
following dosing pumps: DDA, DDC, DDE, • Dimensions: l:400 x w:500 x h:210 mm outside-in
DDI 60-10 and DMX up to 50 l/h. • Power supply: grid power AC connection • Membrane pore size: 0.03 µm
Components available for DTS: 110-240 V, 50/60 Hz • Bacteria/Virus removal: up to log 6 / log 2.5
• Mounting material for the dosing pumps: • Solar panel DC voltage: 15-45 V / 3 A • Turbidity removal: < 0.1 NTU
DDA, DDC, DDE, DDI 60-10 and DMX up to • Water temperature: 0.1 - 30 °C
• Suspended solids removal: < 0.5 mg/l
50 l/h • Pipe connection: inlet 1", outlet 1/2"
• Power supply: 200-240 V, 1-phase, 50/60
• Dosing tanks up to 1000 l • User interface: touch and sound
Hz
• Electric agitator or hand mixer • Water quality: WHO drinking-water
• Dimensions: l:1600 x w:800 x h:2300 mm
• Collecting tray standards
• Remote monitoring for easy maintenance
• Outlet line with flow switch for empty and • Inlet pressure range: 0.2 - 4 bar
planning and downtime reduction
pre-empty indication • Strainer: included
• Internal CIP and backwash systems.
• Multifunction valve • Water Management System: platform for
• Injection unit remote monitoring and data management.
• Dosing line
Applications
• Drain valve Applications • Off-grid community drinking-water supply
• Tank inlet valve. • Water kiosks, in combination with Grundfos
• Water kiosk connected to local water supply
Dosing tank stations are preassembled from AQtap
• Water kiosk connected to water network
the factory. The dosing pump has to be • Water factories and mobile water
• Community drinking-water supply.
ordered separately. containers
• Treatment of water containing bacteria,
Features and benefits viruses and particles
Applications • Transparent and efficient revenue • Treatment of harvested rainwater
• Water and wastewater treatment collection through water credit smart cards • Water treatment for commercial buildings.
• Washing systems • Mobile payment, option for water credit
• Swimming pools purchase
• Process plants
Features and benefits
• Intelligent water management
• Paper production • Self-adaptive control to handle fluctuations
• Solar with battery and/or grid power supply
• Food and beverage industry. in raw water quality
• User-friendly, precise dispensing with
• Optimal reliability and long service intervals
minimum water wastage.
Features and benefits • Solar with battery and /or grid power supply
• Low consumption of energy and chemicals
• Flexible system for a wide range of
• Modular concept for simple optimal system
applications and dosing tasks
sizing
• Suitable for a lot of chemical media due to
• Prefabricated for easy installation.
high quality materials
• Minimal installation and commissioning
effort.

28
DynaFilter CM, CME, CMV CMBE TWIN

Inline process-water treatment system for Multistage centrifugal pumps Frequency-controlled two-pump booster
metal working industry systems

H [m] H [m]
Technical data 100
150
• Capacity: 200-600 l/h 80
100 60
• Compliance: VDA 16 and DIN ISO 16232
Standards 60 40
• Media: water, degreasing chemicals, oil, 40
emulsion 30
20
• Media temperature: 10-65 °C 20
• Operating pressure: max. 3.5 bar
• Membrane material: Ceramic, R-SiC 10 10
0.5 1 2 4 6 10 20 40 1 2 4 6 10 20
• Power consumption: 1-2 kWh/m3 Q [m³/h] Q [m³/h]
• Weight dry: 400 kg
• Dimensions: l:2600 x w:600 x h:1400 mm. Technical data Technical data
Flow rate: max. 36 m3/h Flow rate: max. 16 m3/h
Applications Head: max. 130 m Head: max. 100 m
• Parts washers in metal working industry Liquid temperature: -30 to +120 °C Liquid temperature: 0 to 60 °C
• Total particle and emulsified oil removal. Operating pressure: max. 16 bar Operating pressure: max. 10 bar

Features and benefits Applications Applications


• Dynamic membrane filtration and • Washing and cleaning • Two-family houses
separation technology • Water treatment • Cluster homes
• Saving water, chemicals and energy • Temperature control • Blocks of flats
• Reducing environmental impact and costs • Pressure boosting. • Schools
• Maintenance-free • Small hotels
• Automatic operation • Small industrial plants and businesses
Features and benefits
• Remote monitoring and control • Hospitals
• Compact design
• Very simple installation on existing parts • Agriculture and irrigation.
• Modular design
washers
• Very low noise level down to 50 dB(A).
• Optional CIP unit.
Features and benefits
Options • Constant pressure via integrated speed
• Customised products control
• Built-in or stand-alone • Automatic cascade control and pump
• Variable frequency drive. alternation
• Available as a self-priming variant with a • Multi Master, redundant sensor
suction lift of up to 8 metres. • Compact construction
• Robust, stainless steel
• Easy installation
• Dry-running protection
• Low noise level, 55 dB(A)
• Low energy consumption, IE5 motors.

Options
• Inlet pressure switch that meets DIN
1988-500 (EN 806)
• Stainless steel I (AISI316Ti)
• Manifold kit (inlet and outlet pipes)
• Remote control by means of Grundfos
GO Remote.
• Communication to BMS/SCADA system.

29
CMBE CMB PM1, CMB-SP PM1, CMB PT, CMB PS
CMB PM2, CMB-SP PM2
Frequency-controlled booster systems Pressure manager booster systems Booster systems with CM pumps

H [m] H [m] H [m]


100 60 60
60 40 40
40
20 20
20
10 10
10
6 6
4 4

2
1 2 3 4 5 6 8 10 20 1 2 3 4 6 8 1 2 3 4 5 6 8
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 16 m3/h Flow rate: max. 6.5 m3/h Flow rate: max. 6.2 m3/h
Head: max. 99 m Head: max. 55 m Head: max. 47 m
Liquid temperature: 0 to 60 °C Liquid temperature: 0 to 60 °C Liquid temperature: 0 to 60 °C
Operating pressure: max. 10 bar Operating pressure: max. 10 bar Operating pressure: max. 10 bar

Applications Applications Applications


• Single-family houses • Single- and two-family houses • Single- and two-family houses
• Two-family houses • Cluster homes • Cluster homes
• Cluster homes • Blocks of flats • Blocks of flats
• Blocks of flats • Schools • Schools
• Schools • Small hotels and guest houses • Small hotels and guest houses
• Small hotels and guest houses • Small office buildings. • Small office buildings.
• Small office buildings.
Features and benefits Features and benefits
Features and benefits • Cast-iron and stainless-steel variants • CM pump
• Constant pressure via integrated speed • Compact • Pressure tank to minimise the number of
control • Easy installation pumps starts
• Compact construction • Automatic resetting of alarms • Motor protection (single-phase variants)
• Robust, stainless steel • Dry-running protection • Automatic operation.
• Easy installation • Anti-cycling (leakage detection)
• Dry-running protection • Maximum continuous operating time (CMB
• Low noise level, 55 dB(A) PM2 only)
• Available with inlet pressure switch that • Self-priming down to 8 metres (CMB-SP
meets DIN 1988-500 only).
• Low energy consumption, IE5 motors.
Options
• Available as a self-priming variant with a
suction lift of up to 8 metres.

30
RCME Rainwater control CR, CRI, CRN

Rainwater harvesting system with buffer tank, Control and monitoring unit for rainwater Multistage centrifugal pumps
CME Booster and feed pump harvesting

H [m] H [m]
60 Technical data
300
40 Supply voltage: 3 x 400 V
200
Enclosure class: IP54
20
All motor sizes can be connected. 100
10
6 Applications 50
4
• Rainwater harvesting 30
2 • Cleaning systems 20
0.5 1 2 3 4 56 8 • Washing machines 1 2 5 10 20 50 100 200
Q [m³/h] • Toilet flushing Q [m³/h]
• Garden irrigation.
Technical data Technical data
Flow rate: max. 6 m3/h Features and benefits Flow rate: max. 200 m3/h
Head: max. 50 m • Easy installation and startup Head: max. 330 m
Liquid temperature: 3 to 40 °C • Simple control Liquid temperature: -40 to +180 °C
Operating pressure: max. 10 bar • Application-optimised software Operating pressure: max. 40 bar
• User-friendly operating panel
Applications • Fully scalable for pump and tank(s) Applications
• Rainwater harvesting • Digital outputs for BMS system. • Washing systems
• Cleaning systems • Cooling and air-conditioning systems
• Washing machines • Water supply systems
• Toilet flushing • Water treatment systems
• Garden irrigation. • Firefighting systems
• Industrial plants
Features and benefits • Boiler feed systems.
• Compact solution
• High reliability Features and benefits
• Simple installation • Reliability
• User-friendly operating panel • High efficiency
• Digital outputs for BMS system. • Service-friendly
• Space-saving
• Suitable for slightly aggressive liquids.

Options
• Dry-running protection and motor
protection via LiqTec.

31
CRE, CRIE, CRNE CR, CRN high pressure CRT

Multistage centrifugal pumps - electronically Multistage centrifugal pumps Multistage centrifugal pumps
controlled

H [m] H [m] H [m]

200 400 200


100
200
50 100
20 100
60
10 60
40
5 40

2 20 20
2 5 10 20 50 100 200 1 2 4 6 10 20 40 100 200 1 2 4 6 8 10 20 30
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 180 m3/h Flow rate: max. 180 m3/h Flow rate: max. 22 m3/h
Head: max. 250 m Head: max. 480 m Head: max. 250 m
Liquid temperature: -40 to +180 °C Liquid temperature: -30 to +120 °C Liquid temperature: -20 to +120 °C
Operating pressure: max. 33 bar Operating pressure: max. 50 bar Operating pressure: max. 25 bar

Applications Applications Applications


• Washing systems • Washing systems • Process-water systems
• Cooling and air-conditioning systems • Water treatment systems • Washing in cleaning systems
• Water supply systems • Industrial plants • Seawater systems
• Water treatment systems • Boiler feed systems. • Pumping of acids and alkalis
• Firefighting systems • Ultrafiltration systems
• Industrial plants Features and benefits • Reverse osmosis systems
• Boiler feed systems. • Reliability • Swimming baths.
• High pressures
Features and benefits • Service-friendly Features and benefits
• Wide range • Space-saving • High corrosion resistance
• Reliability • Suitable for slightly aggressive liquids • Reliability
• In-line design • Single-pump solution enabling high • High efficiency
• High efficiency pressure. • Service-friendly
• Service-friendly • Space-saving.
• Space-saving Options
• Many control facilities. • Dry-running protection and motor Options
protection via LiqTec. • Dry-running protection and motor
Options protection via LiqTec.
• Wireless remote control by means of
Grundfos GO Remote.

32
CR DW Hydro MPC Hydro Multi-E

Ejector pumps Turnkey booster system with CR, CRI, CRIE Turnkey booster system with CRE, CRIE or
pumps for transfer and pressure boosting of CME pumps for pressure boosting of water in
water buildings
HD [m] H [m] H [m]
100 150 150
100
80
100 60
60 80 40
60
40 20
40
30 10
6
20 20 4
0.25 0.4 0.6 1 1.5 2 3 5 10 20 50 100 200 5001000 1 2 4 6 10 20 40 60100 200
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Operating pressure: max. 16 bar Flow rate: max. 1080 m3/h Flow rate: max. 140 m3/h
Ambient temperature: max. 40 °C Head: max. 155 m Head: max. 133 m
Liquid temperature: max. 40 °C Liquid temperature: 0 to 60 °C Liquid temperature: 0 to 60 °C
Operating pressure: max. 16 bar Operating pressure: max. 16 bar.
Applications
Minor water-supply systems Applications Applications
• irrigation in agriculture and horticulture • Water supply systems • Blocks of flats
• liquid transfer on farms with own well • Irrigation systems • Hotels
• weekend cottages. • Industrial plants • Hospitals
• Commercial buildings. • Schools
Features and benefits • Office buildings.
• Four sizes and two material versions. One Features and benefits
with all wetted parts made of stainless steel • 2-6 pumps in cascade Features and benefits
• Suitable for wells down to 90 m • Easy installation and startup • 2-4 pumps in cascade
• Service-friendly • Large user-friendly display • Plug-and-pump solution
• Pump head and base made of electro- • Energy-optimised control • Easy to control
plated cast iron. • Data communication • Low energy consumption
• Perfect constant pressure • Data communication
Options • Application-optimised software. • Multimaster function
• Hose kit for simple change from CPE/CPES • Perfect constant pressure.
to CR DW.
Options
• Wireless remote control by means of
Grundfos GO Remote.

33
Hydro Multi-S Hydro Multi-B Hydro Solo-E

Fixed-speed booster system with CR, CM or Turnkey booster system with CM, CME Turnkey booster system with CRE pumps for
CMV pumps pumps for pressure boosting of water in pressure boosting of water in buildings
buildings
H [m] H [m]
H [m]
100 150 200
60 100
100
40 60
40 60
40
20
20 20
10 10 10
6 6 6
4 4 4
1 2 4 6 10 20 40 80 1 2 4 6 10 20 40 60 100 1 2 4 6 10 20 40 80
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 72 m3/h Flow rate: max. 108 m3/h Flow rate: max. 70 m3/h
Head: max. 103 m Head: max. 125 m Head: max. 149 m
Liquid temperature: 5 to 60 °C Liquid temperature: 0 to 60 °C Liquid temperature: 0 to 70 °C
Operating pressure: max. 16 bar Operating pressure: max. 16 bar Operating pressure: max. 16 bar

Applications Applications Applications


• Blocks of flats • Blocks of flats • Single-family houses
• Hotels • Hotels • Cottages
• Schools. • Hospitals • Farms
• Schools • Process water
Features and benefits • Office buildings. • Irrigation.
• 2-3 pumps in cascade
• Plug-and-pump solution Features and benefits Features and benefits
• Simple and robust design • 2-3 pumps in cascade • Plug-and-pump solution
• Easy to service and maintain. • Plug-and-pump solution • Easy to control
• Simple interface for control • Low energy consumption
• Energy-optimised control • Data communication
• Data communication • Perfect constant pressure.
• Perfect constant pressure
• Small footprint. Options
• Wireless remote control by means of
Grundfos GO Remote.

34
BMP BM BMShs, BMST, BMSX

Piston pumps for liquid transfer under high 4", 6", 8" booster modules High-pressure booster systems
pressure

H [m] H [m]
Technical data 400 1000
Flow rate: max. 10.2 m3/h 800
200
Head: max. 1630 m
600
Liquid temperature: 3 to 50 °C 100
500
Operating pressure: max. 160 bar 60
40 400

Applications 300
20
• Cleaning and washing 10 200
• Injecting 1 2 4 10 20 40 100 200 400 10 20 30 40 60 100 150
• Misting Q [m³/h] Q [m³/h]
• Processing
• Desalination of brackish water and Technical data Technical data
seawater. Flow rate: max. 265 m3/h Flow rate: max. 120 m3/h
Head: max. 430 m Head: max. 820 m
Features and benefits Liquid temperature: 0 to 40 °C Liquid temperature: 0 to 40 °C
• High efficiency Operating pressure: max. 60 bar Operating pressure: max. 82 bar
• Small, lightweight pump
• Generates insignificant pulsations in the Applications Applications
outlet line • Reverse osmosis systems • Reverse osmosis systems
• No preventive maintenance required • Water supply systems • Water supply systems
• Long service life • Water treatment systems • Water treatment systems
• Few wear parts • Industrial plants • Industrial plants.
• Wide speed control range • High-rise buildings.
• Extreme recirculation capability without Features and benefits
overheating (up to 90 %) Features and benefits • High-pressure boosting
• Lubricated by the pumped liquid • High-pressure boosting • High-pressure/high-flow
• Compact design. • Various material versions • Low-energy consumption
• Low noise level • Simple installation
• Simple installation • Compact design
• Modular design • Modular design
• Compact design • Leakage-free
• Leakage-free • Small footprint
• In-line. • Low weight
• VFD self-test at startup
• Overload protection
• Low noise level.

Options
• Permanent-magnet high speed
• Asynchronous high-speed motor.

35
BMhp, BMShp SQ, SQE SP A, SP, SP-G

High-pressure booster systems 3" submersible pumps 4", 6", 8", 10", 12" submersible pumps

H [m] H [m] H [m]


150 200 600
100 400
100 200
60
60 100
40
40
40
20 20
20
10 10 10
4 10 20 40 100 200 400 0.2 0.4 0.6 1 2 4 6 810 1 2 4 10 20 40 100200 600
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 310 m3/h Flow rate: max. 9 m3/h Flow rate: max. 470 m3/h
Head: max. 110 m Head: max. 237 m Head: max. 670 m
Liquid temperature: 0 to 40 °C Liquid temperature: 0 to 40 °C Liquid temperature: 0 to 60 °C
Inlet pressure: max. 80 bar Installation depth: max. 150 m Installation depth: max. 600 m
Operating pressure: max. 82 bar
Applications Applications
Applications • Domestic water supply systems • Groundwater supply to waterworks
The BMhp booster module is the optimum • Groundwater supply to waterworks • Irrigation in horticulture and agriculture
solution for these applications: • Irrigation in horticulture and agriculture • Groundwater lowering
• Sealless pumps • Groundwater lowering • Pressure boosting
• Pumps capable of handling high system • Industrial applications. • Industrial applications
pressures • Fountains
• High heads Features and benefits • Mining
• Quiet operation • Integrated dry-running protection • Offshore.
• A minimum of maintenance • Overload protection
• Reverse osmosis systems • Overtemperature protection Features and benefits
• Water supply systems • Over- and undervoltage protection • High efficiency
• Water treatment systems • Protection against upthrust • Stainless steel components throughout and
• Industrial plants. • Wear resistance replaceable wear parts for long service life
• Soft start • Sand content up to 150 g/m3.
Features and benefits • High efficiency.
• High flow Options
• High inlet pressure Options • A wide range of accessories
• Simple installation. • SQE can be protected, monitored and • Grundfos GO Remote, wireless remote
controlled by the CU 300 and CU 301. control
Options • Complete range of zinc anodes for SP
MGE motor • Complete range of flow sleeves for SP
MG motor. • Available in 3 grades of stainless steel, EN
1.4301, EN 1.4401 or EN 1.4539
• Motor protection via MP 204.

36
SQE-NE, SP-NE SQFlex MGFlex

Remediation and sampling pumps Renewable-energy based water supply Renewable-energy based motors and water
systems supply systems

H [m] H [m]
200 240 Technical data
• Power input (P1) of 40 to 880 W and 60 to
200
100 1730 W
60
160 • Motor speed of 1000 to 3600 min-1
40 120 • Maximum input current of 4.6 and 8.9 A.
80 • 30-300 VDC
20 • 1 x 90-240 VAC, 50/60 Hz
40
• The MGFlex motor can be mounted on
10 0 Grundfos CR and MTR (as float pump)
0.2 0.4 1 2 4 6 10 20 0 20 60 80 100
Q [m³/h] Q [m³/day] pumps.

Technical data Technical data Applications


Flow rate: max. 22 m3/h Flow rate: max. 90 m3/day The Grundfos solar surface pump system is
Head: max. 215 m Head: max. 200 m designed for renewable energy supply.
Liquid temperature: 0 to 40 °C Liquid temperature: 0 to 40 °C Powered by a solar panel, the system is
Installation depth: max. 600 m Supply voltage: 30-300 VDC, 1 x 90- especially suitable for supplying water in
240 V, 50/60 Hz applications such as:
Installation depth: max. 150 m • Irrigation
Applications
• Watering of livestock
• Pumping contaminated groundwater
Applications • Pressure boosting
• Sampling
• Villages, schools, hospitals, single-family • Floating pump
• Remedial pumping.
houses • Recirculation of swimming-pool water
• Farms and greenhouses (OEM).
Features and benefits
• Game parks and game farms
• SQE-NE: See SQE Features and benefits
• SP-NE: See SP. • Conservation areas.
• Energy supply from solar modules,
Features and benefits generators or batteries
• Energy supply from solar modules, wind • Maximum power point tracking, MPPT
turbine, generator or batteries • Overvoltage and undervoltage protection
• Maximum power point tracking, MPPT • Wide voltage range
• Simple installation • Overload protection
• Reliable water supply • Overtemperature.
• Virtually no maintenance
• Expansion possibilities
• Cost-efficient pumping
• Dry-running protection.

37
RSI Solar modules CU 200, CIU 273, IO50,
IO101, IO102
Renewable solar inverter for three-phase Solar modules for pumps and systems that Renewable-energy controllers
pumps rely on a renewable-energy source

[A]
Technical data Technical data
1000 W/m2
Input voltage: 400-800 VDC I SC • 30-300 VDC
230-380 VDC 800 W/m2 • 1 x 90-240 VAC, 50/60 Hz.
Output voltage: 3 x 208-240 VAC 600 W/m2
3 x 380-440 VAC Applications
400 W/m2 SQFlex
Motor sizes from 1.5 kW to 37 kW.
200 W/m2 • CU 200: monitoring and tank level control
Applications
100 W/m2 • CIU 273: monitoring, tank level control and
The intelligent IP66 off-grid Solar Inverter U OC
[V] Grundfos Remote Management
• CIU 903: monitoring and tank level control
(RSI) is designed to run with large Grundfos
• SQFlex and MGFlex
pumps, greatly expanding possibilities for Technical data
solar water solutions offering low or nearly no • IO50: on/off control
Peak power: 2700 W
• IO101: on/off control and generator backup
operating costs. Voltage (Ump): 31.4 VDC.
• IO102: on/off control and wind turbine.
The RSI is easy to set up and install, and pairs Current (Imp) 8.76 A
easily with SP submersible pumps as well as Connector MC4
a broad range of Grundfos pumps, creating a Features and benefits
Net weight 18 kg
modular system which allows maximum • Easy installation
components flexibility. • Status indication (CU 200, CIU 273)
Applications • Fault indication (CU 200, CIU 273)
Grundfos solar modules are suitable for the • Automatic AC to DC switch (IO 101)
Features and benefits SQFlex, MGFlex and RSI water supply • Automatic pump operation (CU 200, CIU
• Energy supply from solar modules and systems based on renewable-energy
generators 273, CIU 903).
sources.
• IP66 weatherproof outdoor installation Each solar module is equipped with plugs and
• Quick setup with Grundfos pumps Options
sockets for easy connection of several
• AC/DC compatible • CIU 273 and CIU 903 works with Grundfos
modules in parallel or series. Plugs and
• Maximum power point tracking, MPPT GO Remote.
cables are accessories for some models. The
• Overvoltage and undervoltage protection • CIU 273 and CIU 903 can be used with
solar modules must be mounted on a support
• Overload protection pulsating flow meter.
structure, tilted at an angle ensuring optimum
• Overcurrent protection utilisation of the solar energy.
• Overtemperature protection of inverter
• Operation history memory. Warranties
Power output:
• 25 years limited warranty of 80 % power
output.
• 12 years limited warranty of 90 % power
output.

Workmanship: 2 years.

38
JP JP Booster with pressure JPC, JPA
tank
Self-priming jet pumps for small-scale water Self-priming jet booster for small-scale water Self-priming jet pumps and boosters
supply supply

H [m] H [m] H [m]


50 50 60
30 30 40
20 20 20
10 10 10
5 6
5
4
3
3
2 2
1 1.5 2 3 4 5 6 2 1 2 3 4 5 6 8 10 15
Q [m³/h] 1 1.5 2 3 4 5 6
Q [m³/h]
Q [m³/h]
Technical data Technical data Technical data
Flow rate: max. 5 m3/h Flow rate: max. 5 m3/h Flow rate: max. 10.5 m3/h
Head: max. 48 m Head: max. 48 m Head: max. 61 m
Liquid temperature: 0 to 40 °C (S1) / 60 Liquid temperature: 0 to 40 °C (S1) / 60 Suction lift: max. 8 m
°C (S3) °C (S3) Liquid temperature: 0 to 35 °C
Suction lift: max. 8 m Suction lift: max. 8 m Operating pressure: max. 7.5 bar
Operating pressure: max. 6 bar Operating pressure: max. 6 bar
Applications
Applications Applications • Gardens
• Households • Single- and two-family houses • Hobby activities
• Garden irrigation • Garden irrigation • Agriculture
• Car wash • Car wash • Horticulture.
• Small-scale agriculture and horticulture • Small-scale agriculture and horticulture
• Light commercial applications • Light commercial applications Features and benefits
• Pool cleaning (AISI 316 variant only). • Self-priming
Features and benefits • Strong suction capacity
Features and benefits • Self-priming • Handle small sandy impurities with ease
• Self-priming, featuring a suction lift of up to • Automatic start/stop according to • Built-in thermal protection.
8m consumption
• Robust design and corrosion-free materials • Pressure gauge Options
for a long lifetime • Pressure tanks reduce starts and stops • Available with a pressure manager for
• Lifting handle for easy moving. • Reduced waterhammer in the pipes. automatic start-stop and added protective
functions
Options Options • Available with a pressure tank to minimise
• AISI 316 variant for pool cleaning. • Vertical pressure tank the number of starts
• Horizontal pressure tank. • Available with a pressure switch.

39
JPC PT, JPA PT, JPD PT SCALA2 MQ

Self-priming jet pumps and boosters Single-stage standard pumps - electronically Multistage centrifugal self-priming pumps
controlled

H [m] H [m]
60 50
40
20
20
10
10
6 4
4 2
2 1
1 2 3 4 5 6 8 10 15 0.1 0.2 0.5 1 2 3 5
Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 1000 m3/h Flow rate: max. 4 m3/h Flow rate: max. 5 m3/h
Head: max. 160 m Head: max. 45 m Head: max. 48 m
Liquid temperature: -25 to +140 °C Liquid temperature: 45 to 55 °C Liquid temperature: 0 to 35 °C
Operating pressure: max. 25 bar Operating pressure: max. 10 bar Operating pressure: max. 7.5 bar

Applications Applications Applications


• Single- or two-family households • Pressure boosting of mains water • Single- or two-family houses
• Summer houses and weekend cottages. • Pressure boosting of water from roof tanks • Weekend cottages
• Pressure boosting of water from break • Farms
Features and benefits tanks • Greenhouses.
• Self-priming • Pressure boosting of water from ground
• Robust design water Features and benefits
• Corrosion-free materials • Water supply from shallow wells, less than • All-in-one booster unit
• Constant water supply 8 m. • Easy to install
• Automatic start-stop. • Easy to operate
Features and benefits • Self-priming
• Adjustable constant pressure • Dry-running protection with automatic reset
• Low noise, less than 47 dB(A) in typical use • Low noise level
• Compact • Maintenance-free.
• Robust and reliable
• Easy installation and self-priming
• Dry-running protection.

40

NS, PF RMQ UNILIFT, KPC

Centrifugal pumps and compact peripheral Units for monitoring and control of rainwater Submersible drainage and effluent pumps
centrifugal pumps collection and utilisation systems

H [m] H [m] H [m]


60 50 16
40 14
30 20 12
10 10
20
15 8
4 6
10 4
8 2 2
5 1 0
1 2 3 4 6 10 20 30 40 0.1 0.2 0.5 1 2 3 5 0 5 10 15 20 25 30 35 40
Q [m³/h] Q [m³/h] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 38 m3/h Flow rate: max. 5 m3/h Flow rate: max. 31 m3/h
Head: max. 60 m Head: max. 48 m Head: max. 17 m
Liquid temperature: 0 to 35 °C Liquid temperature: 0 to 35 °C Liquid temperature: 0 to 55 °C
Operating pressure: max. 10 bar Operating pressure: max. 7.5 bar Installation depth: max. 10 m

Applications Applications Applications


• Domestic applications • Single- or two-family houses • Drainage of flooded cellars
• Water supply • Weekend cottages • Pumping of domestic wastewater
• Light gardening applications • Farms • Groundwater lowering
• Draining and filling of cisterns • Gardens and greenhouses. • Emptying of swimming pools and
• Light industrial applications, such as excavations
feeding Features and benefits • Emptying of drain wells
• Pressurised boilers (anti-condensation). • Automatic changeover between rainwater • Emptying of tanks and reservoirs.
tank and integrated mains water tank.
Features and benefits • Manual changeover between rainwater Features and benefits
• The pumps are efficient solutions in a tank and integrated mains water tank. • Simple installation
simple design for the transfer of water. • Acoustic and visual alarm in case of • Service- and maintenance-free.
• The materials of the pumps ensure an overflow in integrated mains water tank.
excellent robustness. Options
• All single-phase versions have built-in Options • Unilift CC is suitable for low suction
overload protection. • Control of additional booster pump • Unilift CC has an optional horizontal outlet
• Backflow monitoring equipment. • Unilift AP35/50 and AP35B/50B have a
vortex impeller
• Unilift AP35B and AP50B have auto-
coupling and horizontal outlet
• KPC 24/7 is suitable for continuous
operation in applications such as fish
pounds.

41
DWK DPK DP, EF

Heavy-duty dewatering pumps Submersible drainage pumps Drainage and effluent pumps

H [m] H [m] H [m]


150 50 30
20
100 40
60 30 10
40
30 20 4
20 2

10 10 1
1 2 4 6 10 20 40 60 150 1 2 4 6 10 20 40 60 1 2 4 6 10 15 20
Q [l/s] Q [I/s] Q [l/s]

Technical data Technical data Technical data


Flow rate: max. 120 l/s Flow rate: max. 45 l/s Flow rate: max. 12.8 l/s (46
Head: max. 160 m Head: max. 51 m m3/h)
Liquid temperature: 0 to 40 °C Liquid temperature: 0 to 40 °C Head: max. 25 m
Liquid temperature: 0 to 40 °C
Applications Applications Outlet diameter: Rp 2 to DN 65
Dewatering Draining
• Construction sites • Underground building pits Applications
• Excavation sites • Industrial pits • Drainage
• Tunnels • Stormwater pits. • Effluent
• Mines • Wastewater
• Draining Features and benefits • Process water.
• Underground building pits • High-pressure capabilities
• Industrial pits • Flexible installation Features and benefits
• Stormwater pits. • Easy to service and maintain. • Cable plug connection
• Unique clamp connection
Features and benefits Options • Single-channel and vortex impellers
• Durability • Different outlet connections • Solids passage up to 65 mm
• Ductile/high-chrome impeller • Auto-coupling system • Unique cartridge shaft seal
• Easy to operate • Monitoring unit. • Modular design
• High efficiency • Minimum downtime.
• Compact design
• High-pressure capabilities. Options
• AUTOADAPT functions
• Available in explosion-proof version
• A wide range of customised solutions
available.

Related products and solutions


• "Control DC"
• Pumping stations; "PS.R", "PS.W" and
"PS.G".

42
SEG S pumps KPL, KPG, KWM

Grinder pumps Supervortex pumps, single- or multichannel Propeller and mixed-flow pumps for column
impeller pumps installation

H [m] H [m] H [m]


50 50
100
30 30
60
20 40 20

10 20 10

5 10 5
3 6 3
2 4 2
1 2 3 4 6 10 20 30 40 10 40 100 200 400 1000 3000 1 2 3 4 6 10 20 30 40
Q [m³/h] Q [l/s] Q [m³/h]

Technical data Technical data Technical data


Flow rate: max. 9.44 l/s Flow rate: max. 2,500 l/s Flow rate: max. 9,200 l/s
Head: max. 47 m Head: max. 116 m Head: max. 25 m
Liquid temperature: 0 to 40 °C Liquid temperature: 0 to 40 °C Liquid temperature: 0 to 40 °C
Outlet diameter: DN 80-800
Applications Particle size: max. ∅ 145 Applications
• Pumping of wastewater with toilet waste • Flood and stormwater control
through pipes of ∅ 40 and up. Applications • Large volume drainage and irrigation
• Transfer of wastewater • Raw-water intake
Features and benefits • Transfer of raw water • Transfer of liquids in large-scale municipal
• Service-friendly • Pumping of sludge-containing water sewage treatment plants
• Installation on foot or auto-coupling • Pumping of industrial effluent. • Circulation of large quantities of water.
• Continuous operation with fully submerged
pump Features and benefits Features and benefits
• Built-in motor protection • SmartTrim • Patented Turbulence Optimizer ™ reducing
• SmartTrim • Operation with or without cooling jacket turbulence and increasing efficiency
• Improved grinder system • Submerged or dry installation • World class total efficiency in a compact
• Totally sealed cable plug. • Different types of impellers and lightweight design.
• Built-in motor protection. • Self-cleaning hydraulics reducing the risk of
Options jamming and clogging
• Wide range of accessories Options • Available with a wide range of sensors
• Monitoring and control of one or several • Control and protection systems • A wide range of customised solutions
pumps • External cooling water available.
• AUTOADAPT functions • External seal flush system
• Available in explosion-proof versions • Sensors for monitoring of pump conditions Related products and solution
• A wide range of customised solutions • Various cast stainless-steel versions • "SRG" recirculation pumps (for lower
available. available flow rates)
• Available in explosion-proof versions • "Control DC"
Related products and solutions • A wide range of customised solutions • "CUE" frequency converters (available
• "Control DC" available. up to 250 kW).
• Pumping stations; "PS.R", "PS.W" and
"PS.G".

43
PS.R PS.W PS.G

PE (polyethylene) pumping stations PE (polyethylene) and PP (polypropylene) GRP (glass-fibre-reinforced polyester)


pumping stations pumping stations

Technical data Technical data Technical data


Diameter: D500/400, D800/ Diameter: D400, D600, Diameter: D1200, D1400,
600, D1000/800, D800, D1000, D1600, D1800,
D1200/1000, D2000 D2000, D2200,
D1700/1400 Depth: 2.25 - 6.0 m D3000
Depth: 1.5 - 6.0 m Outlet pipe size: DN 40-100 Depth: 2.0 - 8.0 m (12 m
Outlet pipe size: DN 40-100 Liquid temperature: max. 40 °C on request)
Liquid temperature: max. 40 °C Pit made of PEHD or PP, pipes and valves Outlet pipe size: DN 50 - DN 250
Pit made of PEHD, pipes and valves made of made of PE or stainless steel. Liquid temperature: max. 40 °C
PE or stainless steel. Made of glass-fibre-reinforced plastic (GRP),
With or without valve chamber. Applications pipes and valves made of PE or stainless
• Drainage steel.
Applications • Effluent, rainwater and surface water With or without valve chamber.
• Drainage • Wastewater.
• Effluent, rainwater and surface water Applications
• Wastewater. Features and benefits • Effluent, rainwater and surface water
• Modular flexibility • Wastewater.
Features and benefits • Corrosion-free materials
• Modular flexibility • Increased base plate prevents buoyancy Features and benefits
• Corrosion-free materials • Easy installation • Modular flexibility
• Increased sump volume prevents buoyancy • Sturdy design • Corrosion-free materials
• Easy installation • Inlet holes drilled on site • Easy installation
• Sturdy design • Design of sump limits sludge and odour • Sturdy design
• Inlet holes drilled on site problems. • Design of sump limits sludge and odour
• Design of sump limits sludge and odour problems.
problems. Options
• Pumps Options
Options • Service-friendly design • Pumps
• Pumps • Controls and communication • Service-friendly design
• Service-friendly design • Valve chambers • Controls and communication
• Controls and communication • Inlet seals • Valve chambers
• Valve chambers • Drills for inlet seals • Service platform
• Inlet seals • Frost protection • Baffle plate
• Drills for inlet seals • Ventilation package • Screen basket
• Frost protection • Frost protection
• Ventilation package • Ventilation package
• Covers for heavy traffic load • Covers for heavy traffic load.
• Inlet screens: baffle plate or screen basket
(D1700)
• Mixer (D1700).

44
AMD, AMGEx, AFGEx SMD, SMG, SFG SRG

Mixers and flowmakers Mixer and flowmakers Submersible recirculation pumps

H [m]
Technical data Technical data
2.0
Liquid temperature: 5 to 40 °C Thrust: 360-6570 N 1.5
pH value: 4-10 Thrust-to-power ratio: 0.251 - 1.338
1.0
Axial thrust: 160-6632 N Liquid temperature: 5 to 40 °C 0.8
Max. dynamic viscosity: 500 mPa s pH value: 4-10 0.6
Max. density: 1060 kg/m3 Max. dynamic viscosity: 500 mPa s
0.4
Max. instal. depth: 20 m Max. density: 1060 kg/m3
Propeller diameter: 180-2600 mm Max. instal. depth: 20 m
Rotation speed: 22-1410 min-1 Propeller diameter: 180-2600 mm 0.2
20 50 100 200 500 1000 2000
Rotation speed: 22-1410 min-1 Q [l/s]
Applications
• Municipal wastewater treatment systems Applications Technical data
• Industrial processes • Wastewater treatment plants Flow rate: max. 1430 l/s
• Sludge treatment systems • Tanks for biological treatment of activated (5130 m3/h)
• Agriculture sludge Head: max. 2.1 m
• Biogas plant. • Tanks for secondary wastewater treatment Liquid temperature: 5 to 40 °C
• Mixing Outlet diameter: DN 300, 500, 800.
Features and benefits • Biogas tanks
• Wide range of flexible installation • Stormwater tanks Applications
accessories • Industrial processes • Recirculation of activated sludge in
• Easy to maintain and service without use of • Sludge treatment systems wastewater treatment plants
special tools • Agriculture. • Pumping of stormwater.
• Electronic leak sensor in gearbox or shaft
seal housing Features and benefits Features and benefits
• Shaft seal protected against abrasive • High thrust-to-power ratios • High-efficiency stainless-steel impeller
materials • Low energy consumption • Low energy consumption
• Self-cleaning stainless-steel or polyamide • Smooth design, strong axial gear for high • Smooth design, strong axial gear for high
propellers. hydrodynamic efficiency hydrodynamic efficiency
• Integrated leak sensor • Integrated leak sensor
Related products and solutions • Integrated overload and thermal protection • Integrated overload and thermal protection
• "CUE" frequency converters (available up • Flexible installation accessories for a wide • Overload protection.
to 250 kW). range of applications
• Service-friendly products without the need
Related products and solutions
for special tools
• "CUE" frequency converters (available up
• Robust shaft seal system for protection
to 250 kW).
against abrasives
• Self-cleaning hydraulics.

Related products and solutions


• "CUE" frequency converters (available up
to 250 kW).

45
SE, SL CU 100 LC, LCD

Heavy-duty submersible pumps Small pump control units Pump controllers with pneumatic signal, float
switch or electrodes

H [m]
80 Technical data Technical data
50 Supply voltage: 1 x 230, 3 x 230, Supply voltage: 1 x 230, 3 x 230,
30 3 x 400 V, 50 Hz 3 x 400 V, 50/60 Hz
20
Applications Applications
10
The control unit CU 100 is designed for the • Pumping stations
5 starting, operation and protection of small • Filling and emptying of tanks.
3 pumps.
1 2 5 10 20 50 200 1000 The control unit is suitable for the following Features and benefits
Q [m³/h] operating currents: • Control of one, LC, or two pumps, LCD
• Single-phase: up to 9 A • Automatic alternating operation, LCD
Technical data • Three-phase: up to 5 A. • Automatic test run preventing shaft seals
Flow rate: max. 305 l/s (1100 m3/h) from seizing up during long periods of
Head: max. 71.3 m Features and benefits inactivity
Free passage: 50-125 mm • Control of one pump. • Water hammer protection
pH range: 0-14 • Start-stop by means of a float switch or • Starting delay after power failure
Outlet diameter: DN 65-300. manual start-stop. • Stop delays
• Several variants for single- and three- • Automatic alarm reset, if required
Applications phase pumps. • Automatic restart, if required
• Drainage water and surface water • Single-phase control units are supplied with • Liquid level indication
• Domestic and municipal wastewater capacitors and with or without float switch. • High-level alarm
• Industrial wastewater • Three-phase control units are supplied with • Motor overload protection relay
• Process and cooling water. a float switch. • Protection against motor overheating via
• IP54 cabinet with screwed metric cable input from PTC resistor or thermal switch.
Features and benefits entries.
• Service-friendly (smartdesign) Optional
• Reliable and energy efficient • SMS modem with built-in hour and start
• Intelligent solution (AUTOADAPT) counter (information on mobile phone)
• S-tube® or SuperVortex impellers • Hours counter
• Available with built-in sensors and in • Start counter
explosion-proof versions • Signal lamp
• A wide range of customised solutions • Acoustic signal
available. • External main switch.

Related products and solutions


• Grundfos "Control DC"
• Pumping stations; "PS.R", "PS.W" and
"PS.G".
• "CUE" frequency converters (available up
to 250 kW)

46
Control DC UNOLIFT/DUOLIFT MULTILIFT

Pump controller based on dedicated controls Advanced lifting stations for grey and black Advanced lifting stations for grey and black
wastewater. wastewater

H [m] H [m]
Technical data 50 30
Supply voltage: 1 x 230, 3 x 230, 30
3 x 400 V, 50/60 Hz 20
20

Applications 10
10
Control DC is suitable in wastewater 5
applications for emptying wastewater pits (up 3
6
to six pumps). 2 4
• Pressurised pumping stations 1 2 4 6 10 15 20 1 10 20 30 50
• Network pumping stations Q [m³/h] Q [l/s]
• Commercial buildings.
Technical data Technical data
Features and benefits Flow rate: max. 5.5 l/s (20 m3/h) Flow rate: max. 60 l/s (216 m3/h),
• Automatic energy optimisation Head: max. 46 m 31 l/s recommended
• Advanced flow calculation Liquid temperature: 0-40 °C (110 m3/h)
• Easy installation and configuration Outlet diameter: DN40/DN50 Head: max. 29 m
• Configuration wizard Liquid temperature: 0 to 40 °C
• Electrical overview Applications Outlet diameter: DN 80-100.
• Advanced data communication Wastewater collection from sanitary
• Advanced alarm and warning priority appliances and removal. Applications
• Supports several languages • Single- and multifamily houses Wastewater collection from sanitary
• Daily emptying • Weekend cottages appliances and removal.
• Mixer control or flush valve • Restaurants • Single- and multifamily houses
• User-defined functions • Hotels • Weekend cottages
• Anti-blocking • Sewage systems in the open country. • Restaurants
• Start level variation • Hotels
• Advanced pump alternation with pump Features and benefits • Sewage systems in the open country.
groups • Easy to setup and to install
• SMS scheduling • Flexible pipe connection Features and benefits
• Communication to SCADA, BMS, GRM or • Solids passage up to 50 mm or use of a • Ready for installation
cell phone. grinder pump • Flexible pipe connection
• Low risk of clogging • Cable plug connection
Optional • Low operating costs • Single-channel and vortex impellers
• Available as ready-made Control DC unit or • Pumps with thermal protection. • Solids passage up to 100 mm
as dedicated control module for local • Low risk of clogging
assembly. • Minimum downtime
• Low operating costs
• Liquidless motor cooling
• Unique cartridge shaft seal
• Modular design
• Pumps placed on or beside the collecting
tank
• Equipped with level sensors and controller
• Pre-assembled and configured, ready to
plug and pump.

47
SOLOLIFT2 LIFTAWAY B and C CONLIFT1

Domestic lifting stations Domestic lifting stations Condensate lifting stations

H [m]
Applications Technical data 6.0
WC-1, WC-3 and CWC-3 Liftaway B 4.0
• Designed for toilets, CWC-3 for wall-hung Inlet dimension: 3 x DN 100 2.0
toilets, for easy integration into the wall. Outlet connection: DN 40
C-3 Effective volume: 40 l. 1.0
• Designed for grey wastewater from 0.6
washing machines or dishwashers. Liftaway C 0.4
D-2
Inlet dimension: 3 x DN 100 + 1 x 0.2
• Compact design for grey wastewater from
DN 40/50 0.1 0.2 0.3 0.4 0.6
washing machines, dishwashers, etc. Q [m³/h]
Outlet connection: DN 40
Examples Effective volume: 13 l.
Technical data
• Extra bathrooms
Applications Flow rate: max. 588 l/h
• Basement installations
• Collection of drainage and surface water Head: max. 5.7 m
• Low-cost bathrooms in holiday cottages
• Collection and pumping of wastewater from Liquid temperature: max. 50 °C (90 °C for
• Added facilities in hotels and guest houses
basement and laundry rooms below sewer 5 minutes)
• Bathrooms for the elderly or the disabled
level pH: min. 2.5
• Renovation of offices and other commercial
• Collection and pumping of wastewater from Tank volume: 2.65 l
buildings.
washbasins, washing machines and floor Effective volume: 0.9 l.

Features and benefits drains to sewer level


• Collection and pumping of rainwater. Applications
• Compact and slim design with smooth line
CONLIFT1 is designed for the pumping of
and rounded edges - fits every modern
Features and benefits condensate from the following:
bathroom environment
• To be fitted with pumps from the Unilift KP • Boilers
• Low noise level
and AP range. • Air-conditioning systems
• Flexible outlet pipe adapters for outer pipe
• Cooling and refrigeration systems
diameters of ∅ 22, ∅ 25, ∅ 28, ∅ 32, ∅ 36
Liftaway B • Air dehumidifiers
and ∅ 40
• Telescopic part for easy height adjustment • Evaporators.
• Thermal overload switch
• Easy service • Flexible and easy installation.
• Easy connection of extra sanitary Features and benefits
appliances. Liftaway C • Fully sealed against moisture and
• Functional design and easy to clean evaporation
• Overflow protection device • Very silent and smooth operation
• Active carbon filter to eliminate odours • Neutralisation unit with granulate for pH
• Compact and slim for easy installation values below 2.5
under a washbasin or in a closet. • Selectable position of neutralisation unit
• Acoustic high-water alarm device
• Boiler source off.

48
SB SBA MS

Submersible pumps for rainwater and Submersible fully automatic pump solution for Stainless-steel 4" and 6" submersible motors
shallow well applications rainwater and shallow wells applications

H [m] H [m]
Technical data
40 40
Motor sizes
20 20 4": 0.37 - 7.5 kW
10 10 6": 5.5 - 30 kW.

4 4 Applications
2 2 The Grundfos MS submersible motors can be
fitted on all Grundfos SP A, SP pumps and
1 1
0.5 1 2 4 6 8 0.5 1 2 4 6 8 can be used in the high-pressure booster
Q [m³/h] Q [m³/h] modules, type BM and BMB.

Technical data Technical data Features and benefits


Flow rate: max. 6.6 m3/h Flow rate: max. 6.6 m3/h • Liquid temperature: 0-60 °C
Head: max. 43 m Head: max. 43 m • Overtemperature protection via power
Liquid temperature: 5 to 40 °C Liquid temperature: 0 to 40 °C cable by means of a built-in Tempcon
temperature transmitter.
Applications Applications • Standardised NEMA flange and shaft end
• Rainwater applications • Rainwater applications • Mechanical shaft seal, ceramic/carbon or
• Private wells. SiC/SiC
• Completely encapsulated in stainless steel
Features and benefits
• Canned type submersible motor, all
• Private wells Features and benefits
surfaces in contact with the liquid are made
• Noiseless operation • Simplicity - all-in-one unit
of stainless steel
• High reliability • Easy installation - no external control unit
• Liquid-cooled and liquid-lubricated
• Dry-running protection • Noiseless operation
bearings.
• Motor overload protection. • High reliability
• Integrated dry-running protection
Options
Options • Motor overload protection
• Automatic start-stop • Material variants EN 1.4301 and EN
• Floating inlet strainer model available.
• Lifting eye. 1.4539.
• Motor protection by means of MP204
• Variable speed option.
Options
• Floating inlet strainer model available
• Float switch.

49
MMS LiqTec CUE

Stainless-steel 6", 8", 10", 12" rewindable Control and monitoring units Frequency converters for three-phase pumps
submersible motors

Technical data Applications Technical data


Motor sizes • Monitoring and protection of pumps and • Mains voltage:
6": 3.7 - 37 kW processes. 1 x 200-240 V
8": 22-110 kW 2 x 200-240 V
10": 75-190 kW Features and benefits 3 x 380-500 V
12": 147-250 kW. • Protection against dry running 3 x 525-600 V
• Protection against liquid temperatures 3 x 575-690 V.
Applications exceeding 130 °C ± 5 °C
The Grundfos MMS submersible rewindable • Protection against too high motor Applications
motors can be fitted on all Grundfos SP and temperatures Adjustment of the pump performance to the
SP-G pumps. • Manual or automatic restarting possible demand. Together with sensors, the CUE
from a remote PC offers these control modes:
Features and benefits • Simple installation: plug-and-play • proportional differential pressure
technology • constant differential pressure
• Liquid temperature: 0-50 °C
• Easily rewound • Robust sensor. • constant pressure
• constant pressure with stop function
• Protection against upthrust
• constant level
• High efficiency
• 6" and 8" have standardised NEMA flange • constant level with stop function
• constant flow rate
and shaft end
• constant temperature.
• Mechanical shaft seal, ceramic/carbon or
SiC/SiC The CUE can also be controlled by an
external signal or via GENIbus.
• PVC or PE/PA windings.

Options Features and benefits


• Material variants EN 1.4301, EN 1.4401 • Adjustment of the pump performance to the
demand, thus saving energy.
and EN 1.4539.
• Easy installation, as the CUE is designed
• Overtemperature protection via Pt100/
Pt1000. for Grundfos pumps.
• Short-circuit-protected output; no motor-
protective circuit breaker required.
• Fault indication via display and a relay, if
fitted.
• External setpoint influence via three
programmable inputs.

50
MP 204, CU 300, CU 301, Control MPC Control MPC series 2000
IO 113, SM 113
Control and monitoring units Control and monitoring units Control and monitoring units for series 2000
pumps

Applications Technical data Technical data


Monitoring and protection of pump • Control of up to six identical pumps in • Control of up to six Grundfos MAGNA,
installations. parallel UPE, TPE series 2000 pumps of identical
• Motors from 0.37 - 75 kW can be connected pump type and size
Features and benefits (on request up to 315 kW) • Supply voltage: 1 x 100-240 V
• Protection against too high motor • Enclosure class: IP55. • All motor sizes can be connected
temperature • Enclosure class: IP54.
• Constant monitoring of pump energy Applications
consumption • Heating systems Applications
• MP 204, CU 300 and CU 301 protection • Air-conditioning systems • Heating systems
against dry running • Cooling systems • Air-conditioning systems.
• IO 113 and SM 113 monitoring of water-in- • Booster systems
oil and vibration level. • Industrial processes Features
• Water supply systems. • Easy installation and startup
Options • Simple control
• Connection to large control systems via bus The Control MPC is designed for these pump • Application-optimised software
communication types: • Modular solution with possibility of
• Connection of sensors enabling control • CR, CRE, CRI, CRIE, CRN, CRNE expansion
based on sensor signals • NB, NBE, NBG, NBGE Data communication via PROFIBUS,
• Grundfos GO Remote, wireless remote • NK, NKE, NKG, NKGE PROFINET, LON, Modbus RTU, Modbus
control of MP 204, CU 300 and CU 301. • TP TCP, BACnet MS/TP, BACnet IP, GRM, GRM
• TPE series 1000 IP.
• HS
• SP.

Features and benefits


Optimal adjustment of the performance to the
demand by closed-loop control of these
parameters:
• Proportional differential pressure
• Constant differential pressure
• Differential pressure, remote*
• Flow rate*
• Temperature*
• Temperature difference*.

* External sensor required.

51
Control DDD CIM, CIU Grundfos GO Remote

Control and monitoring units Fieldbus communication interfaces Grundfos GO Remote – The Remote Control
for Grundfos E-products

Technical data Technical data Technical data


• Control of up to six identical pumps in The CIM, CIU interfaces enable the Grundfos MI 204 for iPod and iPhone.
parallel connection of Grundfos electronic products to Grundfos MI 301 for Android.
• Motors from 0.37 - 220 kW can be standard fieldbus networks. CIM can be
connected installed as an add-on module in many E- Pump communication: IR and radio.
• Enclosure class: IP55 pumps and CU 323, 352, 354 and 362. For
• Up to 10 remote sensors. other products, use the CIU box with internal Applications
power supply. Wireless communication with Grundfos
Applications products for status information and control.
• Water distribution. Applications The following Grundfos product types are
• Heating systems supported:
Features • Cooling systems • MAGNA
Demand Driven Distribution (DDD) offers the • Booster systems • UPE
next level in water distribution with critical • Industrial processes • CRE, CRIE, CRNE, CME
point measurement and advanced flow • Water supply systems • MTRE, SPKE, CRKE
adaptation, resulting in the following benefits: • Wastewater pumping systems • TPE, TPED
• Reduced leakage • Dosing and disinfection. • NBE, NKE
• Reduced energy consumption The following product ranges are supported: • Hydro Multi-E
• Higher comfort • MAGNA3 • SEG, DP, EF, SL1, SLV AUTOADAPT
• Fewer pipe breaks • CRE, CRNE, CRIE, MTRE, CME, NBE, • CU 300
• Connection to SCADA via bus NKE, TPE2, TPE3, CUE • CU 301
communication. • Hydro MPC, Control MPC, Multi-E, Multi-B* • IO 351
• MP 204* • MP 204
• Control DC* • CU3.
• SEG, DP, EF, SL1, SLV AUTOADAPT*
• DDA Dosing* Features and benefits
• Demand-driven distribution*. • Intuitive user interface with context related
help
* Not supported by all CIM, CIU types. • Product dashboard for quick overview
• Quick pump setup, monitoring and fault
Features finding
• Available with GENIbus, BACnet MS/TP, • Installation report in PDF format
BACnet IP, LON, Modbus RTU, Modbus • Product info from Grundfos Product Center
TCP, PROFIBUS DP, PROFINET IO, • Find replacement pump
EtherNet/IP, GRM/ GiC and cellular • Product catalogue.
interfaces
• Modular design
• Based on standard functional profiles
• Able to save time and resources, and to
allow predictive maintenance and plant
optimisation due to remote control and
monitoring.

52
DPI V.2 DPI RPI, RPI+T

Differential-pressure sensor for industry, v.2 Differential-pressure sensor for industry Relative-pressure sensor and temperature
sensor, industry

Technical data Technical data Technical data


Pressure range: 0-6 bar Pressure range: 0-10 bar Pressure range: 0-25 bar
Temperature range: 0 to 100 °C Power supply: 12-30 VDC Temp. range (RPI+T): 0 to 100 °C
Power supply: 12.5 - 30 VDC Output signal: 4-20 mA Power supply: 12.5 - 30 VDC
Output signal: 4-20 mA Operating temperature: -10 to +70 °C Output signal: 4-20 mA
Operating temperature: -30 to +120 °C Operating temperature: -30 to +120 °C
Applications
Applications • Water treatment and distribution Applications
• Water treatment and distribution • Water utility • Water treatment and distribution
• Water utility • Water monitoring • Water utility
• Water monitoring • HVAC systems • Water monitoring
• HVAC systems • Chiller systems • HVAC systems
• Chiller systems • HPC and IT cooling systems • Chiller systems
• HPC and IT cooling systems • Micro CHP • HPC and IT cooling systems
• Micro CHP • Heat pumps • Micro CHP
• Heat pumps • Solar systems: heating and cooling. • Heat pumps
• Solar systems: heating and cooling. • Solar systems: heating and cooling.
Features and benefits
Features and benefits • Compact design Features and benefits
• Compact design • Compatible with wet, aggressive media • Compact design
• Standard M12 connector • Accurate, linearised and temperature- • Standard M12 connector
• Pressure and temperature measurement in compensated output signal • RPI+T: pressure and temperature
one sensor (two-in-one solution) • Cost-effective and robust design measurement in one sensor (two-in-one
• Compatible with wet, aggressive media • System solution with Grundfos pumps. solution)
• Accurate, linearised and temperature • Compatible with wet, aggressive media
compensated output signal Options • Accurate, linearised and temperature-
• Quick temperature response: direct contact • Upgrade package for TP1000 compensated output signal
with medium • Power supply SI 001 PSU for cable lengths • RPI+T: quick temperature response (direct
• Cost-effective and robust design greater than 30 m. contact with medium)
• System solution with Grundfos pumps. • Cost-effective and robust design
• System solution with Grundfos pumps.

53
RPS, DPS VFI VFS

Relative- and differential-pressure sensors, Vortex flow sensor, industry Vortex flow sensors for liquids, standard
standard for liquids

Technical data Technical data Technical data


RPS range: 0-10 bar Flow range: 0.3 - 240 m3/h Flow range: 1-400 l/min
DPS range: 0-6 bar Power supply: 12.5 - 30 VDC Power supply: 5 V DC PELV
Power supply: 5 VDC PELV Output signal: 0.5 - 3.5 V Output signal: 0.5 - 3.5 V
RPS output signal: 0.5 - 3.5 V Operating temperature: 0 to 100 °C Operating temperature: 0 to 100 °C
DPS output signal: 0.5 - 4.5 V Temperature range: 0 to 100 °C
Operating temperature: 0 to 100 °C Applications
Temperature range: 0 to 100 °C • Water treatment and distribution Applications
• Water utility • Water treatment and distribution
Applications • Water monitoring • Water utility
• Water treatment and distribution • HVAC systems • Water monitoring
• Water utility • Chiller systems • HVAC systems
• Water monitoring • HPC and IT cooling systems • Chiller systems
• HVAC systems • Micro CHP • HPC and IT cooling systems
• Chiller systems • Heat pumps • Micro CHP
• HPC and IT cooling systems • Solar systems: heating and cooling. • Heat pumps
• Micro CHP • Solar systems: heating and cooling.
• Heat pumps Features and benefits
• Solar systems: heating and cooling. • Compact design Features and benefits
• No moving parts • Compact design
Features and benefits • Compatible with wet, aggressive media • Flow and temperature measurement in one
• Compact design • Accurate, linearised and temperature- sensor (two-in-one solution)
• Pressure- and temperature-sensor in-one compensated output signal • No moving parts
(two-in-one solution) • Quick temperature response: direct contact • Compatible with wet, aggressive media
• Compatible with wet, aggressive media with medium • Accurate, linearised and temperature-
• Accurate, linearised and temperature- • Cost-effective and robust design compensated output signal
compensated output signal • System solution with Grundfos pumps. • Quick temperature response: direct contact
• Quick temperature response: direct contact with medium
with medium • Cost-effective and robust design
• Cost-effective and robust design • System solution with Grundfos pumps.
• System solution with Grundfos pumps.
Options
Options • Power supply and signal converter SI 010
• SI 010 CNV power supply and signal CNV for desired output signals of 4-20 mA,
converter for desired output signals of 4-20 1-5 V and 2-10 V.
mA, 1-5 V and 2-10 V.

54
PM1, PM2 pressure PM Rain GT Pressure tanks
managers
For automatic start-stop of pumps For automatic start-stop of pumps in Diaphragm and bladder tanks for expansion
rainwater-harvesting installations and pressure boosting

Technical data Technical data Technical data


Operating pressure: max. 10 bar Flow rate: max. 75 l/min Diaphragm tanks
Liquid temperature: 0 to 55 °C Mains pressure, p: max. 200 kPa Tank size: 8-5000 l
Ambient temperature: max. 40 °C Horizontal tank size: 20-100 l
Applications Liquid temperature: 0 to 40 °C Tank body material: Low-carbon sheet
PM1 and PM2 pressure managers are Voltage: 240 V, 50 Hz steel (GT-C:
designed for automatic start-stop control of Mains inlet: 3/4" BSP (female) composite body)
Grundfos pumps and other water supply Pump inlet: 1" (male) Liquid temperature: max. 90 °C (GT-
pumps Home-only outlet: 3/4" (female) HR)
• Single-family houses Garden-only outlet: 1" (male) Product range: GT-C, GT-D, GT-H
• Blocks of flats and GT-HR
• Summer houses and holiday cottages Applications Operating pressure: 6, 8, 10 and 16 bar
• Horticulture and gardening PM Rain allows you to utilise your harvested
• Agriculture rainwater for toilet flushing and laundry Bladder tanks
• Rainwater applications. applications, with the added benefit of mains Vertical tank size: 8-5000 l
water backup. Used in conjunction with a Tank body material: Low-carbon sheet
Features and benefits Grundfos pump, either a submersible or steel
• User-friendly interface above-ground pump depending on tank. Flange material Stainless steel EN
• Free position in installation • Single-family houses 1.4401 (AISI 316)
• Flexible power supply • Summer houses and holiday cottages Liquid temperature: max. 90 °C
• Incorporates functions which protect the • Horticulture and gardening Operating pressure: 6, 8, 10 and 16 bar
pump. • Rainwater applications. Product range: GT-U, GT-U+
Options: Coated flange
Features and benefits (GT-U)
• WaterMark Approval
• Quick installation - no float Applications
• Dual check valve for backflow prevention • Domestic, commercial and industrial
• Garden supply from tank only system
• Water source indicator lights • Water supply
• Switches to mains water in the event of • Boosting
power failure • Irrigation
• Automatic start-stop when demand is • Heating and chilled-water system.
sensed.
Features and benefits
Special notice • Optimal water supply
Only available in the Asian Pacific region. • Controlled pressure
• Reduce number of pump starts
• Ideal for drinking water
• Indoor and outdoor use. C2 corrosivity
category rated according to IOS 12944
• Replaceable bladder.

55
56
57
Argentina Denmark Latvia Slovenia
Bombas GRUNDFOS de Argentina S.A. GRUNDFOS DK A/S SIA GRUNDFOS Pumps Latvia GRUNDFOS LJUBLJANA, d.o.o.
Ruta Panamericana km. 37.500 Centro Martin Bachs Vej 3 Deglava biznesa centrs Leskoškova 9e, 1122 Ljubljana
Industrial Garin DK-8850 Bjerringbro Augusta Deglava ielā 60, LV-1035, Rīga, Phone: +386 (0) 1 568 06 10
1619 Garín Pcia. de B.A. Tlf.: +45-87 50 50 50 Tālr.: + 371 714 9640, 7 149 641 Telefax: +386 (0)1 568 06 19
Phone: +54-3327 414 444 Telefax: +45-87 50 51 51 Fakss: + 371 914 9646 E-mail: tehnika-si@grundfos.com
Telefax: +54-3327 45 3190 E-mail: info_GDK@grundfos.com
www.grundfos.com/DK Lithuania South Africa
Australia GRUNDFOS Pumps UAB Grundfos (PTY) Ltd.
GRUNDFOS Pumps Pty. Ltd. Estonia Smolensko g. 6 16 Lascelles Drive, Meadowbrook Estate
P.O. Box 2040 GRUNDFOS Pumps Eesti OÜ LT-03201 Vilnius 1609 Germiston, Johannesburg
Regency Park Peterburi tee 92G Tel: + 370 52 395 430 Tel.: (+27) 10 248 6000
South Australia 5942 11415 Tallinn Fax: + 370 52 395 431 Fax: (+27) 10 248 6002
Phone: +61-8-8461-4611 Tel: + 372 606 1690 E-mail: lgradidge@grundfos.com
Telefax: +61-8-8340 0155 Fax: + 372 606 1691 Malaysia
GRUNDFOS Pumps Sdn. Bhd. Spain
Austria Finland 7 Jalan Peguam U1/25 Bombas GRUNDFOS España S.A.
GRUNDFOS Pumpen Vertrieb Ges.m.b.H. OY GRUNDFOS Pumput AB Glenmarie Industrial Park Camino de la Fuentecilla, s/n
Grundfosstraße 2 Trukkikuja 1 40150 Shah Alam E-28110 Algete (Madrid)
A-5082 Grödig/Salzburg FI-01360 Vantaa Selangor Tel.: +34-91-848 8800
Tel.: +43-6246-883-0 Phone: +358-(0) 207 889 500 Phone: +60-3-5569 2922 Telefax: +34-91-628 0465
Telefax: +43-6246-883-30 Telefax: +60-3-5569 2866
France Sweden
Belgium Pompes GRUNDFOS Distribution S.A. Mexico GRUNDFOS AB
N.V. GRUNDFOS Bellux S.A. Parc d’Activités de Chesnes Bombas GRUNDFOS de México S.A. de Box 333 (Lunnagårdsgatan 6)
Boomsesteenweg 81-83 57, rue de Malacombe C.V. 431 24 Mölndal
B-2630 Aartselaar F-38290 St. Quentin Fallavier (Lyon) Boulevard TLC No. 15 Tel.: +46 31 332 23 000
Tél.: +32-3-870 7300 Tél.: +33-4 74 82 15 15 Parque Industrial Stiva Aeropuerto Telefax: +46 31 331 94 60
Télécopie: +32-3-870 7301 Télécopie: +33-4 74 94 10 51 Apodaca, N.L. 66600
Phone: +52-81-8144 4000
Switzerland
Belarus Germany Telefax: +52-81-8144 4010 GRUNDFOS Pumpen AG
Представительство ГРУНДФОС в GRUNDFOS GMBH Bruggacherstrasse 10
Минске Schlüterstr. 33 Netherlands CH-8117 Fällanden/ZH
220125, Минск 40699 Erkrath GRUNDFOS Netherlands Tel.: +41-44-806 8111
ул. Шафарнянская, 11, оф. 56, БЦ Tel.: +49-(0) 211 929 69-0 Veluwezoom 35 Telefax: +41-44-806 8115
«Порт» Telefax: +49-(0) 211 929 69-3799 1326 AE Almere
Тел.: +7 (375 17) 286 39 72/73 e-mail: infoservice@grundfos.de Postbus 22015
Taiwan
Факс: +7 (375 17) 286 39 71 Service in Deutschland: 1302 CA ALMERE GRUNDFOS Pumps (Taiwan) Ltd.
E-mail: minsk@grundfos.com e-mail: kundendienst@grundfos.de Tel.: +31-88-478 6336 7 Floor, 219 Min-Chuan Road
Telefax: +31-88-478 6332 Taichung, Taiwan, R.O.C.
Bosnia and Herzegovina Greece E-mail: info_gnl@grundfos.com Phone: +886-4-2305 0868
GRUNDFOS Sarajevo GRUNDFOS Hellas A.E.B.E. Telefax: +886-4-2305 0878
Zmaja od Bosne 7-7A, 20th km. Athinon-Markopoulou Av. New Zealand
BH-71000 Sarajevo P.O. Box 71 GRUNDFOS Pumps NZ Ltd.
Thailand
Phone: +387 33 592 480 GR-19002 Peania 17 Beatrice Tinsley Crescent GRUNDFOS (Thailand) Ltd.
Telefax: +387 33 590 465 Phone: +0030-210-66 83 400 North Harbour Industrial Estate 92 Chaloem Phrakiat Rama 9 Road,
www.ba.grundfos.com Telefax: +0030-210-66 46 273 Albany, Auckland Dokmai, Pravej, Bangkok 10250
e-mail: grundfos@bih.net.ba Phone: +64-9-415 3240 Phone: +66-2-725 8999
Hong Kong Telefax: +64-9-415 3250 Telefax: +66-2-725 8998
Brazil GRUNDFOS Pumps (Hong Kong) Ltd.
BOMBAS GRUNDFOS DO BRASIL Unit 1, Ground floor Norway Turkey
Av. Humberto de Alencar Castelo Branco, Siu Wai Industrial Centre GRUNDFOS Pumper A/S GRUNDFOS POMPA San. ve Tic. Ltd. Sti.
630 29-33 Wing Hong Street & Strømsveien 344 Gebze Organize Sanayi Bölgesi
CEP 09850 - 300 68 King Lam Street, Cheung Sha Wan Postboks 235, Leirdal Ihsan dede Caddesi,
São Bernardo do Campo - SP Kowloon N-1011 Oslo 2. yol 200. Sokak No. 204
Phone: +55-11 4393 5533 Phone: +852-27861706 / 27861741 Tlf.: +47-22 90 47 00 41490 Gebze/ Kocaeli
Telefax: +55-11 4343 5015 Telefax: +852-27858664 Telefax: +47-22 32 21 50 Phone: +90 - 262-679 7979
Telefax: +90 - 262-679 7905
Bulgaria Hungary Poland E-mail: satis@grundfos.com
Grundfos Bulgaria EOOD GRUNDFOS Hungária Kft. GRUNDFOS Pompy Sp. z o.o.
Slatina District Tópark u. 8 ul. Klonowa 23
Ukraine
Iztochna Tangenta street no. 100 H-2045 Törökbálint, Baranowo k. Poznania Бізнес Центр Європа
BG - 1592 Sofia Phone: +36-23 511 110 PL-62-081 Przeźmierowo Столичне шосе, 103
Tel. +359 2 49 22 200 Telefax: +36-23 511 111 Tel: (+48-61) 650 13 00 м. Київ, 03131, Україна
Fax. +359 2 49 22 201 Fax: (+48-61) 650 13 50 Телефон: (+38 044) 237 04 00
email: bulgaria@grundfos.bg India Факс.: (+38 044) 237 04 01
GRUNDFOS Pumps India Private Limited Portugal E-mail: ukraine@grundfos.com
Canada 118 Old Mahabalipuram Road Bombas GRUNDFOS Portugal, S.A.
GRUNDFOS Canada Inc. Thoraipakkam Rua Calvet de Magalhães, 241
United Arab Emirates
2941 Brighton Road Chennai 600 096 Apartado 1079 GRUNDFOS Gulf Distribution
Oakville, Ontario Phone: +91-44 2496 6800 P-2770-153 Paço de Arcos P.O. Box 16768
L6H 6C9 Tel.: +351-21-440 76 00 Jebel Ali Free Zone
Phone: +1-905 829 9533 Indonesia Telefax: +351-21-440 76 90 Dubai
Telefax: +1-905 829 9512 PT. GRUNDFOS POMPA Phone: +971 4 8815 166
Graha Intirub Lt. 2 & 3 Romania Telefax: +971 4 8815 136
China Jln. Cililitan Besar No.454. Makasar, GRUNDFOS Pompe România SRL
GRUNDFOS Pumps (Shanghai) Co. Ltd. Jakarta Timur Bd. Biruintei, nr 103
United Kingdom
10F The Hub, No. 33 Suhong Road ID-Jakarta 13650 Pantelimon county Ilfov GRUNDFOS Pumps Ltd.
Minhang District Phone: +62 21-469-51900 Phone: +40 21 200 4100 Grovebury Road
Shanghai 201106 Telefax: +62 21-460 6910 / 460 6901 Telefax: +40 21 200 4101 Leighton Buzzard/Beds. LU7 4TL
PRC E-mail: romania@grundfos.ro Phone: +44-1525-850000
Phone: +86 21 612 252 22 Ireland Telefax: +44-1525-850011
Telefax: +86 21 612 253 33 GRUNDFOS (Ireland) Ltd. Russia
Unit A, Merrywell Business Park ООО Грундфос Россия
U.S.A.
COLOMBIA Ballymount Road Lower ул. Школьная, 39-41 GRUNDFOS Pumps Corporation
GRUNDFOS Colombia S.A.S. Dublin 12 Москва, RU-109544, Russia 9300 Loiret Blvd.
Km 1.5 vía Siberia-Cota Conj. Potrero Phone: +353-1-4089 800 Тел. (+7) 495 564-88-00 (495) 737-30-00 Lenexa, Kansas 66219
Chico, Telefax: +353-1-4089 830 Факс (+7) 495 564 8811 Phone: +1-913-227-3400
Parque Empresarial Arcos de Cota Bod. E-mail grundfos.moscow@grundfos.com Telefax: +1-913-227-3500
1A. Italy
GRUNDFOS Pompe Italia S.r.l. Serbia Uzbekistan
Cota, Cundinamarca Grundfos Tashkent, Uzbekistan The Repre-
Phone: +57(1)-2913444 Via Gran Sasso 4 Grundfos Srbija d.o.o.
I-20060 Truccazzano (Milano) Omladinskih brigada 90b sentative Office of Grundfos Kazakhstan in
Telefax: +57(1)-8764586 Uzbekistan
Tel.: +39-02-95838112 11070 Novi Beograd
Croatia Telefax: +39-02-95309290 / 95838461 Phone: +381 11 2258 740 38a, Oybek street, Tashkent
GRUNDFOS CROATIA d.o.o. Telefax: +381 11 2281 769 Телефон: (+998) 71 150 3290 / 71 150
Buzinski prilaz 38, Buzin Japan www.rs.grundfos.com 3291
HR-10010 Zagreb GRUNDFOS Pumps K.K. Факс: (+998) 71 150 3292
Phone: +385 1 6595 400 1-2-3, Shin-Miyakoda, Kita-ku, Singapore
Telefax: +385 1 6595 499 Hamamatsu GRUNDFOS (Singapore) Pte. Ltd. Addresses Revised 15.01.2019
www.hr.grundfos.com 431-2103 Japan 25 Jalan Tukang
Phone: +81 53 428 4760 Singapore 619264
GRUNDFOS Sales Czechia and Telefax: +81 53 428 5005 Phone: +65-6681 9688
Slovakia s.r.o. Telefax: +65-6681 9689
Čajkovského 21
Korea
779 00 Olomouc GRUNDFOS Pumps Korea Ltd. Slovakia
Phone: +420-585-716 111 6th Floor, Aju Building 679-5 GRUNDFOS s.r.o.
Yeoksam-dong, Kangnam-ku, 135-916 Prievozská 4D
Seoul, Korea 821 09 BRATISLAVA
Phone: +82-2-5317 600 Phona: +421 2 5020 1426
Telefax: +82-2-5633 725 sk.grundfos.com
ECM: 1256742
V7055161 0319

GRUNDFOS A/S

www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark
Trademarks displayed in this material, including but not limited to Grundfos, the Grundfos logo and “be think innovate” are registered trademarks owned by The Grundfos Group. All rights reserved. © 2019 Grundfos Holding A/S, all rights reserved.

Anda mungkin juga menyukai