outlet pipe to
returned at soffit
height of pipe at 1:12
drainage soak
pit/percolation trenches
General Notes
slope
750 190
Inlet
600 120
pipe L1 L2 H1 H2 B Cu. M
1540mm 760mm 1600mm 1750mm 760mm 3.2 10
1900mm 900mm 1800mm 2000mm 900mm 4.5 20
2000mm 1000mm 1800mm 2100mm 1100mm 5.9 30
2400mm 1100mm 1800mm 2100mm 1150mm 7.24
120
40
190
2500mm 1200mm 1800mm 2100mm 1300mm 8.6 50
2700mm 1300mm 1800mm 2100mm 1400mm 10 60
ROOF SLAB PLAN 40x30x3mm th. x 29000mm 1400mm 1800mm 2100mm 1450mm 11.3 70
30
40
650mm long Brollo 3000mm 1500mm 1800mm 2100mm 1560mm 12.7 80
channel bolted to wall 1600mm
3200mm 1800mm 2100mm 1600mm 14 90
with 3No. 12mm dia.
bolts 3300mm 1700mm 1800mm 2100mm 1700mm 15.4 100
B C 4000mm 2200mm 1800mm 2100mm 2190mm 24 150
650
L1 240 L2 240 40x80x4mm th. x 4500mm 2700mm 1800mm 2100mm 2650mm 34.3 200
40mm wide Brollo
angle bolted to wall
80
with 2No. 12mm dia.
rawbolts
240
B
75 75
Water proof rendering in
two 10mm layers each
layer brashed with
50
vandex 20
175
50
20
240
B C 240
150
200
375
60
500
H1
250 x 400mm
800
Beam
50mm 250mm RC
blinding Slab
50mm
SECTION A - A blinding