Tetra Pak Dairy & Beverage Systems AB 1(4)

Issue date: 2008-02-01 Revison: 1


Validity: Issued by:
Approved by: Charlotta Steffner
________________________________________________________________________________________

Performance Criteria “Flow rate accuracy” and Testing


Procedure for Tetra Alcip 100
General

This document describes the performance criteria flow rate accuracy for

• Tetra Alcip 100, all options (Defined in Price Book 2006)


and the method to verify that the criteria are fulfilled.

This document in combination with “Model documents for plant sales” forms a
Performance guarantee towards the customer.

Performance Definitions

The parameters to be verified are flow rate, measured as litre per hour (l/h) at
return inlet and pressure measured in bar at Tetra Alcip 100 pressure outlet pipe.

General definitions:

ΔQ = average flow rate- design flow rate (l/h)

P = design pressure (bar)

Process Performance Criteria

Value: ΔQ ≥ 0 l/h when the pressure P ≤ design pressure

Required utilities should have parameters according to Tetra Pak’s design criteria.

The Tetra Alcip 100 should at the time for the Performance test be running in
normal CIP processing mode.

The flow and pressure meters should be fine tuned and configured after Tetra
Pak’s instructions.

Test Procedures

The performance test shall be done at the end of commissioning on a fine tuned,
continuously running Tetra Alcip 100.

D&B MS 119
Tetra Pak Dairy & Beverage Systems AB 2(4)
Issue date: 2008-02-01 Revison: 1
Validity: Issued by:
Approved by: Charlotta Steffner
________________________________________________________________________________________

Data sampling

When the unit is in production and the defined flow rate is achieved and stable, the
values of flow and pressure are read simultaneously on the HMI on the control
panel and documented.

This is done 30 times within a period of 30 minutes (approximately 1 minute


between readings).

Data analysis

The average flow rate and average pressure is calculated and the result is then
checked against the Process Performance Criteria, see above.

D&B MS 119
Tetra Pak Dairy & Beverage Systems AB 3(4)
Issue date: 2008-02-01 Revison: 1
Validity: Issued by:
Approved by: Charlotta Steffner
________________________________________________________________________________________

Evaluation document

All performance data should be recorded in a standard evaluation document


applicable to the evaluated process, see example below (Excel).

Readings Flow, Q Pressure


l/h bar
1 15200 2,86792453
2 15400 2,90566038
3 15600 2,94339623
4 15700 2,96226415
5 15000 2,83018868
6 15100 2,8490566
7 15400 2,90566038
8 15200 2,86792453
9 15100 2,8490566
10 15000 2,83018868
11 15300 2,88679245
12 15200 2,86792453
13 15100 2,8490566
14 15000 2,83018868
15 15400 2,90566038
16 15200 2,86792453
17 15400 2,90566038
18 15200 2,86792453
19 15200 2,86792453
20 15300 2,88679245
21 15400 2,90566038
22 15600 2,94339623
23 15200 2,86792453
24 15300 2,88679245
25 15100 2,8490566
26 15000 2,83018868
27 15100 2,8490566
28 15100 2,8490566
29 15200 2,86792453
30 15200 2,86792453
Average 15240 2,88
Design value 15000 3
ΔQ, P 240 0
Check ≥ 0 L/h ≤design value
Result OK OK

D&B MS 119
Tetra Pak Dairy & Beverage Systems AB 4(4)
Issue date: 2008-02-01 Revison: 1
Validity: Issued by:
Approved by: Charlotta Steffner