Anda di halaman 1dari 20

PENGOPERASIAN PLTU MAMUJU

TIPE CFB (CIRCULATING FLUIDIZED BED)

Berikut adalah data teknis PLTU Mamuju lengkap dengan cara


mengoperasikannya dari awal hingga unit berbeban.

A. Data Teknis
1. DESIGN SPESIFICATION
Output Capacity :50 MW
Main Fuel : Coal
Initial firing : HSD
Unit number : 2 (two)
SPESIFIKASI BATUBARA
Total moisture : 34,01 % (AR)
Proximate Analysis
 Inherent moisture : 13,92 % (ADB)
 Ash content : 6,39 % (ADB)
 Volatile matter : 40,83 % (ADB)
 Fixed carbon : 38,86 % (ADB)
Total sulfur : 0,83 % (ADB)
Gross calorivic value : 5311 kcal/kg (ADB)
Gross calorivic value : 4071 kcal/kg (AR)
Ultimate Analysis
 Inherent moisture : 10,53 % (ADB)
 Ash : 5,94 % (ADB)
 Total sulfur : 0,44 % (ADB)
 Total Nitrogen : 0,79 % (ADB)
 Hydrogen : 4,18 % (ADB)
 Carbon : 64,86 % (ADB)
 Oxygen : 13,26 % (ADB)
Ash Analysis
 SiO2 : 52,31 %
 Al2O : 27,91 %
 Fe2O3 : 3,85 %
 CaO : 2,04 %
 MgO : 3,08 %
 K2O : 0,39 %
 Na2O : 2,64 %
 MnO2 : 0,05 %
 TiO2 : 1,69 %
 P2O5 : 0,44 %
 SO4 : 5,40 %
Undeterminated : 0,20 %
SPESIFIKASI AIR BOILER
Condensate Pump / Deaerator / Economizer
 pH : 9 - 9,6
 Spec. conductivity : 3-11 µS/cm
 Cation conductivity : < 0,5 µS/cm
 Total iron : < 0,020 mg/l
 Total copper : < 0,003 mg/l
 Silica : < 0,020 mg/l
 Dissolved oxygen : <0,01mg/l
 Residual hydrazine : 0,01 mg/l

Boiler Drum
 pH : 9,1- 9,8
 Spec. conductivity : < 40 µS/cm
 Silica : < 0,300 mg/l

Steam
 pH : 9-9,6
 Spec. conductivity : 3-11 µS/cm
 Cation conductivity : < 0,2 µS/cm
 Total iron : < 0,020 mg/l
 Total copper : < 0,003 mg/l
 Silica : < 0,020 mg/l

Make Up Water/Closed cooling Syatem


 Spec. conductivity : <0,5 µS/cm
 Total iron : < 0,020 mg/l
 Total copper : < 0,003 mg/l
 Silica : < 0,020 mg/l

2. TURBIN AREA EQUIPMENT

a. Steam Turbine
Manufacturer : Fuji Electric System
Type : Non reheat Condensing
Rated speed : 3.000 rpm
Main Steam Pressure : 128 kg/cm2g
Main steam temp. : 538 ⁰C
Intake water : Deep sea intake
Discharge system : Surface disch

b. Generator System
Manufacturer : Fuji Electric System
Type : GTLR I 544/61-2
Capacity : 125-500 kVA
Voltage : 11 kV
Current : 6587 A
Power factor : 0,8
Exitation : 435 V/983 A
Cooler : Air

c. Generator Transformer
Manufacturer : Pauwels
Type : OLD 125.5/325
Capacity : 75/100/125.5 MVA
Voltage : 11 kV/150 kV

d. Intake traveling screen


Quantity : 2 x 50 %
Type : Through flow & traveling type
Flow rate : 9.750 m3/h

e. Sodium Hypoclorite dosing device


Quantity : 3 x 100 % (common)
Type : Electrolitic type
Sea water flow rate : 2 x 48 m3/h
Generating rate : 3 x 40 kg/h

f. Circulatung Water Pump (CWP)


Quantity : 2 x 50 %
Type : Fixed vane, 2nd floor mounted,
mixed flow pump
Flow rate : 9.750 m3/h (max. Flow rate: 11.700
m3/h/120 % of rated flow rate)
Rated total head : 17,5 m
Motor rated output : 650 kW

g. Debris Filter
Quantity : 2 x 50 %
Circulating water flow rate
(rated flow rate) : 9.620 m3/h
(max.flow rate) : 10.920 m3/h
(min flow rate) : 4.810 m3/h
Design pressure : 3,1 kg/cm
Mesh size of filter : 5 mm diameter

h. Condeser
Quantity : 1 unit
Type : Surface condensing double flow
pass water
box half divided type
Heat transfer area : 4.830 m2
Flow rate : 18.500 m3/h
Sea water inlet temp. : 30 ⁰C
Sea water side design press. : 3,1 kg/cm2
i. Ball Cleaning Facility
Quantity : 2 x 50 %
Circulating water flow rate
(rated flow rate) : 9.620 m3/h
(max. Flow rate) : 10.440 m3/h (108 % of rated flow
rate)
Design pressure : 3.1 kg/cm2
Mesh size of screen : 7,5 mm2

j. Primary Cooling Water Booster Pump


Quantity : 2 x 100 %
Type : Horizontal shaft centrifugal type
Rated flow rate : 740 m3/h (max. 110 % of rated
flow rated)
Rated total head :8m
Motor rated out. : 30 kW

k. Boiler Feed Pump (BFP)


Quantity : 3 sets each unit (50 % each set for
TWO condition)
Type : Horizontal, multi stage, centrifugal
type.
Flow rate : 202 t/h
Total Head : 155 kg/cm2
Temperature : 169,3 ⁰C
Weight vol. Ratio : 0,898 kg/litre
Speed of rotation : 3000 rpm (synchronous)
Efficiency : 78 % at above operating cond.
Motor type : Totally enclosed air to air cooled
type
Output motor : 1450 kW
Voltage : AC 6000 V
Number of pole :2P

l. Condensate Pump (CP)


Quantity : 2 sets for each other (100 % each
set for TVWO condition)
Type : Vertical, multi stage, barrel type
Flow rate : 340 t/h
Total head : 17 kg/cm2
Temperature : 42,2 oC
Weight vol. Ratio : 0,991 kg/litre
Speed of rotation : 1500 rpm (synchronous)
Efficiency : 76,5 % at above operating
condition
Motor type : Totally enclosed air to air cooled
type
Otput motor : 240 kW
Voltage : AC 6000 V
Number of pole :4P
m. Closed Cooling Water Pump (CCWP)
Quantity : 2 sets each unit (2 sets x 100%)
Type : Horizontal, centrifugal pump
Flow rate : 650 m3/h
Total head : 40 m
Temperature : 45 OC
Weight vol. Ratio : 0,990 kg/litre
Speed of rotation : 1500 rpm (synchronous)
Efficiency : 74 %
Motor type : Totally enclosed air to air cooled type
Output motor : 110 kW
Voltage : AC 400 V
Number of pole :4P

n. HP No.5 Feed Water Heater


Fluid : Steam (shell), feed water (channel)
Operating press : 31,8 kg/cm2a (shell)
Flow rate : 24.350 kg/h (shell), 352.320 kg/h
(channel)
Inlet Temp. : 345,8 oC (shell), 201 oC (channel)
Outlet Temp. : 206,6 oC (shell), 235 oC (channel)

o. HP No.4 Feed Water Heater


Fluid : Steam (shell), feed water (channel)
Operating press : 17,16 kg/cm2a (shell)
Flow rate : 20.530 kg/h (shell), 352.320 kg/h
(channel)
Inlet Temp. : 269,5 oC (shell), 169,1 oC
(channel)
Outlet Temp. : 174,7 oC (shell), 201 oC (channel)

p. LP No.2 Feed Water Heater


Fluid : Steam (shell), feed water
(channel)
Operating press : 3,14 kg/cm2a (shell)
Flow rate : 21.310 kg/h (shell), 287.540 kg/h
(channel)
Inlet Temp. : 134,5 oC (shell), 92,8 oC (channel)
Outlet Temp. : 98,4 oC (shell), 131,7 oC (channel)

q. LP No.1 Feed Water Heater


Fluid : Steam (shell), feed water (channel)
Operating press : 0,881 kg/cm2a (shell)
Flow rate : 23.150 kg/h (shell), 287.540 kg/h
(channel)
Inlet Temp. : 95,6 oC (shell), 42,7 oC (channel)
Outlet Temp. : 48,4 oC (shell), 92,8 oC (channel)

r. Deaerator
Design press. : 8,6 kg/cm2g
Design temp. : 260 ºC
Operating press. : 7,45 to 7,84 kg/cm2
Operating temp. : 167 to 169 ºC
Outlet capacity : 381.120 kg/hr
Storage capacity : 55 cubic meters from NWL to
Empty
Oxygen guarantee : 0,005 ml/l (7 ppb)
Capacity : 55 m3

3. BOILER AREA

a. Steam generation
Manufacturer : Alstom Power Inc.
Steam generator : 400 ton/hour
Feed water temp. : 238 0C
Outlet pressure : 128 kg/cm2g
Superheater outlet : 538 oC
Precipitator : Bag filter
Firing system : CFB

b. Induced Draft Fan (IDF)


Manufacture : WESTING HOUSE
Type : Centrifugal double inlet
Kecepatan : 991 rpm
Daya : 1679 HP
Tegangan : 6000 Volt
Frekuensi : 50 Hz
Phase : 3 phasa

c. Fluidizing Air Blower (FAB)


Manufacture : Web Blower
Tegangan : 6000 volt
Kecepatan : 2974 rpm
Daya : 225 kW
Power factor : 0.85
Frekuensi : 50 Hz
Berat : 1,9 Ton

d. Secondary Air Fan (SAF)


Manufacture : WESTING HOUSE
Type : Sentrifugal
Kecepatan : 1468 rpm
Daya : 750 HP
Tegangan : 6000 Volt
Frekuensi : 50 Hz
Phase : 3 phasa

e. Primery Air Fan (PAF)


Manufacture : WESTING HOUSE
Type : Sentrifugal
Kecepatan : 1481 rpm
Daya : 2735 HP
Tegangan : 6000 Volt
Frekuensi : 50 Hz
Phase : 3 phasa

f. Burner
Manufacture : Coen Company Inc.
Capacity : 175 mmBtu/hr on #2 Oil
Press. Fuel oil : 180 Psig
Flow fuel oil : 23,5 GPM
Atomizing media : udara
Press. Atomizing : 50 Psig
Flow atomizing : 520 SCFM
Cooling/purge air : 60 SCFM @ 10” W.C. when
exhausted to 0” W.C.
Weight : 3.500 lbs

4. WATER TREATMENT AREA EQUIPMENT

a. Desalination Plant
Manufacturer : Sasakura Engineering
Type : Flash evaporator
Capacity : 500 ton/day

b. Desalination Feed Pump


Maufacture : TATUNG
Power : 100 HP
Pole :4
Voltage : 400 V
Current : 133 A
Speed : 1475 rpm
Frequency : 50 Hz
Type pump : VPFC-M
Capacity : 375 m3/h
Head : 38 m

c. Blowdown motor
Manufacture : TOSHIBA
Power : 11 kW
Type : IKK
Frequency : 50 Hz
Speed : 1450 rpm
Pole :4
Voltage : 400 v
Current : 12,4 A

d. Brine Blowdown
Manufacture : HONDA
Type : GF
Capacity : 70 m3/h
Speed : 1450 rpm
Power : 11 kW
Head : 20 m

e. Distillate Pump Motor


Manufacture : TOSHIBA
Power : 7,5 kW
Type : IKK
Speed : 1450 rpm
Voltage : 400 v
Current : 14,3 A

f. Distilate Pump
Manufacture : HONDA
Type : GS
Capacity : 30 m3/h
Head : 36 m
Speed : 1450 rpm
Power : 7,5 kW

g. Demineralisation Plant
Manufacture : Doshion
Type : Resin Mixed Bed
Capacity : 370 ton/day

h. Vacuum pump motor


Manufacture : Kirloskar
Power : 2,20 kW
Speed : 2830 rpm
Voltage : 400 v
Current : 4,5 A
Type pump : WVS 30 A
Speed pump : 2880 rpm
HP pump :3

i. Booster Pump
Manufacture : Kirloskar
Power : 5,5 kW
Speed : 2900 rpm
Votage : 400 v
Current : 10 A
Type pump : CPHM 36/16
Total head :35 m
Discharge : 20 m3/h
Pump input : 3,38 kW

j. Water Treatment supply pump


Manufacture : Kirloskar
Power : 5,5 kW
Speed : 2900 rpm
Votage : 400 v
Current : 10 A
Type pump : CPHM 46/16
Total head : 30 m
Discharge : 30 m3/h
Pump input : 3,92 kW

k. Regeneration water pump


Manufacture : Kirloskar
Power : 5,5 kW
Speed : 2900 rpm
Votage : 400 v
Current : 10 A
Type pump : CPHM 40/16
Total head :35 m
Discharge : 25 m3/h
Pump input : 3,9 kW

l. Demin water supply


Manufacture : TECO
Power : 5,5 kW
Speed : 1445 rpm
Voltage : 400 v
Current : 11,4 A
Speed pump : 1450 rpm
Total head : 25 m
Capacity : 40 m3/h
HP : 75

m. Service water supply


Manufacture : TECO
Power : 37 kW
Speed : 2995 rpm
Voltage : 400 v
Current : 66,12 A
Speed pump : 1450 rpm
Total head : 25 m
Capacity : 40 m3/h
HP : 50

n. Mixed Bed Air Blower


Manufacture : Crompton Greaves
Power : 5,5 kW
Speed motor : 1440 rpm
Voltage : 400 ± 10 % v
Current : 11 A
Speed pump : 2268 rpm
Air flow : 144 m3/h
HP : 7,5

o. Acid Transfer Pump


Power : 3,7 kW
Speed : 2830 rpm
Voltage : 400 v
Current : 7,1 A
Speed pump : 2900 rpm
Total head : 20 m
Capacity : 1,5 m3/h
HP :5

p. Caustic Transfer Pump


Power : 3,7 kW
Speed : 2830 rpm
Voltage : 400 v
Current : 7,1 A
Speed pump : 2900 rpm
Total head : 20 m
Capacity : 1,5 m3/h
HP :5
q. Caustic Unloading Pump
Power : 3,7 kW
Speed : 2830 rpm
Voltage : 400 v
Current : 7,1 A
Speed pump : 2900 rpm
Total head : 20 m
Capacity : 30 m3/h
HP :5
Head : 20 MLC

r. Acid Unloading Pump


Power : 3,7 kW
Speed : 2830 rpm
Voltage : 400 v
Current : 7,1 A
Speed pump : 2900 rpm
Total head : 20 m
Capacity : 30 m3/h
HP :5
Head : 20 MLC

s. Bulk Acid Storage Tank


Design pressure : Atmospheric
Design temperature : 40 0C
Nominal diameter :1800 mm
Nominal Height : 3000 mm
Nominal Capacity : 8 m3
t. Demin Water Storage Tank
Design pressure : Atmospheric
Design temperature : 40 0C
Nominal diameter :1100 mm
Nominal Height : 9150 mm
Nominal Capacity : 869 m3

u. Micron Cartridge Filter


Design pressure : 4 kg/cm2 g
Design temperature : 50 0C (max)
Nominal diameter : 273 mm
Nominal Height : 900 mm
Nominal Capacity : 9,23 m3

v. Sodium Sulphite Storage Tank


Design pressure : Atmospheric
Design temperature : Ambient
Nominal diameter : 500 mm
Nominal Height : 700 mm
Nominal Capacity : 0,1 m3
w. Caustic Measuring Tank
Design pressure : Atmospheric
Design temperature : Ambient
Nominal diameter : 500 mm
Nominal Height : 700 mm
Nominal Capacity : 0,1 m3

x. Acid Measuring Tank


Design pressure : Atmospheric
Design temperature : Ambient
Nominal diameter : 500 mm
Nominal Height : 700 mm
Nominal Capacity : 0,1 m3

y. Air Receiving Tank


Working pressure : 10 kg/cm2
Testing Pressure : 15 kg/cm2
Design Temperature : 37,7 oC

z. Air Compressor
Pressure max. : 8,6 kg/cm2
Flow : 73,9 l/s
Power motor : 30 kW
Speed : 2960 rpm

5. COAL, ASH & LIMESTONE HANDLING AREA EQUIPMENT

a. Silo’s capacity
Coal storage silo : 2 x 15.000 ton
Coal Bunker : 3 x 400 ton
Disposal ash silo : 1 x 875 m3
Limestone silo : 1 x 2000 ton

b. S1-S6
Equipment : Pipe conveyor
Capacity : 400 t/h
Belt width : 1300 (Ф350)
Belt speed :155m/min
Motor power : 45 kW (S1-S4)
: 110 kW (S5)
: 90 kW (S6)
c. A1 & A3
Equipment : belt conveyor
Capacity : 400 t/h
Belt speed : 150,9 m/min
Motor power : 11 kW (A1)
: 15 kW (A3)

d. A2
Equipment : Steep sloped conv.
Capacity : 400 t/h
Belt speed : 150 m/min
Motor power : 132 m/min

e. CR1-1/1-2/2-1/2-2
Equipment : Rot. plow reclaimer
Capacity : 200 t/h
Belt speed :
Wheel speed : 0,3-2,4 m/min
Traveling speed : 0,45-1,0 m/min
Motor power : 11 (wheel)
: 1,5x2 (traveling)

f. B-11/21 BC & B-12/22 BC


Equipment : Belt conveyor
Capacity : 200 t/h
Belt speed : 80,5
Motor power : 11 (B-11/21)
: 22 (B-12/22)

g. B-13/23
Equipment : Belt conveyor
Capacity : 200 t/h
Belt speed : 40,8 m/min
Motor power : 3,7 kW

h. B-14/24
Equipment : Pipe conveyor
Capacity : 200 t/h
Belt speed : 125 m/min
Motor power : 37 kW

i. B-14A/24A
Equipment : Belt conveyor
Capacity : 200 t/h
Belt speed : 80,5 m/min
Motor power : 15 kW

j. B-15/25
Equipment : Bucket elevator
Capacity : 200 t/h
Belt speed : 35 m/min
Motor power : 55 kW

k. B-16/26 ; B-17/27 ; B-18/28


Equipment : Case conveyor
Capacity : 200 t/h
Belt speed : 20 m/min
Motor power : 30 kW

l. C-1/2
Equipment : Belt conveyor
Capacity : 200 t/h
Belt speed : 40,8 m/min
Motor power : 3,7 kW

m. E-1/2
Equipment : Case conveyor
Capacity : 200 t/h
Belt speed : 20 m/min
Motor power : 15 kW

n. BF-11/21
Equipment : Belt feeder
Capacity : 200 t/h
Belt speed : 29,7 m/min
Motor power : 7,5 kW

o. CS-11/21
Equipment : Screw conveyor
Capacity : 50 t/h
Belt speed : 68,7 rpm
Motor power : 5,5 kW

p. CB-11/21
Equipment : Bucket elevator
Capacity : 50 t/h
Belt speed : 23,5 m/min
Motor power : 11 kW
Bab II. SETTING VALUE PERALATAN

Setiap peralatan yang ada memiliki batasan-batasan nilai maksimum yang aman
untuk beroperasi, hal ini bertujuan untuk menjaga kondisi setiap peralatan dan sistem
dimana dia berada. Pemahaman mengenai nilai seting ini menjadi penting bagi
operator agar dapat mengoperasikan unit pembangkit dengan aman. Berikut adalah
data Nilai Seting setiap parameter operasi PLTU Tarahan.

LIST OF SETTING VALUE

Item Setting Value Keterangan


PRESSURE
Furnace HHH +3,73 kPa Trip FA Blower
pressure HH +2,49 kPa Trip PAF & SAF
H +1,49 kPa MFT
LL -1,74 kPa MFT
LLL -2,24 kPa MFT
Main steam SV 114 kg/cm2g Turbin initial lim. pres.
press.
Gland seal SV 0,1 kg/cm2g Gland steam control valve
steam header
Condensate H ≥0,05 kg/cm2 Alarm
pump suction
strainer press.
differential
Condensate L ≤ 4,6 kg/cm2 Alarm (standby CP auto start)
pump discharge
pressure
BFP suction H ≥0,5 kg/cm2a Alarm
strainer pressure
differential
BFP discharge L ≤148,5kg/cm2 Alarm (standby BFP auto start)
pressure
CCW supply L ≤4,5 kg/cm2g Alarm (standby CCWP auto start)
pressure
MOP discharge L ≤4,6 kg/cm2g Alarm (standby MOP & EOP start
press automatically)
Lube oil L ≤1,3 kg/cm2g Alarm (EOP start automatically)
pressure
Lube oil filter H ≥0,5 kg/cm2g Alarm
pressure
differential
LP trip oil LL ≤2,0 kg/cm2g Trip
pressure Alarm
COP suction fiter H ≥0,2 kg/cm2 Alarm (local flag indication)
pressure
differential
COP line fiter H ≥7 kg/cm2 Alarm
pressure
differential
Polishing filter H ≥1,12 kg/cm2 Alarm
pressure
differential
Last chance fiter H ≥0,2 kg/cm2 Alarm (local flag indication)
pressure
differential
L ≤105 kg/cm2 Alarm (standby COP start utomatically)
Control oil
LL ≤70 kg/cm2 Trip (2 out of 3)
pressure
Alarm
Charging press range 1-1,5 kg/cm2g At 20 oC
of accumulator
(lube oil line)
Charging press range 79-84 kg/cm2g At 20 oC
of accumulator
(control oil line)
Condenser water H 0,2 kg/cm2 For priming of condenser water box
box pressure
Debris filter H 0,1 kg/cm2 Alarm
pressure
differential
Ball cleaning H 0,03 kg/cm2 Alarm
strainer pressure
differential
HH 0,05 kg/cm2 Alarm
Primary cooling L 0,5 kg/cm2g Alarm (standby CCWP start)
water discharge
pressure
TEMPERATURE
Main steam H ≥546 oC Alarm
temperature L ≤515 oC ( Alarm
100 MW)
LL ≤495 (100 Trip
MW)
LP stationary H ≥180 oC Alarm (LP casing spray auto start)
blade temp. HH ≥230 oC Trip (2 out of 3)
Exhaust temp. H ≥90 oC Alarm (LP casing spray auto start)
HH ≥110 oC Trip (2 out of 3)
Gland sealing HH ≥350 oC Alarm (gland steam stop valve & control
steam temp. valve close)
Not HH ≤340 oC gland steam stop valve & control valve open
H ≥340 oC Alarm
L ≤250 oC Alarm (gland steam trap bypass vale open)
Not L ≥260 oC gland steam trap bypass vale close
LL ≤240 oC Gland steam stop valve & control ave close
Not LL ≥250 oC Gland steam stop valve & control ave open
H ≥ ±50 oC Alarm
Differential HH ≥ ± 70 oC Trip (by manual)
temp.between
turbine upper
casing & lower
casing.
Lube oil H ≥ 50 oC Alarm
temperature/TCV
outlet
ST no.1 journal H ≥ 100 oC Alarm
bearing metal HH ≥120 oC Trip (by manual)
temp.
Thrust bearing H ≥ 100 oC Alarm
metal temp. HH ≥120 oC Trip (by manual)
(front)
Thrust bearing H ≥ 100 oC Alarm
metal temp. HH ≥120 oC Trip (by manual)
(rear)
ST no.2 journal H ≥ 100 oC Alarm
bearing metal HH ≥120 oC Trip (by manual)
temp.
GEN no.1 H ≥ 100 oC Alarm
journal bearing HH ≥120 oC Trip (by manual)
metal temp.
GEN no.2 H ≥ 100 oC Alarm
journal bearing HH ≥120 oC Trip (by manual)
metal temp.
Control oil H ≥55 oC Control oil radiator fan ON
temp.in control Not H ≤48 oC Control oil radiator fan OFF
oil tank HH ≥70 oC Alarm
L ≤33 oC Control oil heater fan ON
Not L ≥43 oC Control oil heater fan OFF
ST no.1 journal H ≥77 oC Alarm (check lubricating oil cooler outlet
bearing drain oil temp.)
temp. trip by manual
ST no.2 journal H ≥77 oC Alarm (check lubricating oil cooler outlet
bearing drain oil temp.)
temp. trip by manual
GEN no.1 H ≥77 oC Alarm (check lubricating oil cooler outlet
journal bearing temp.)
drain oil temp. trip by manual
GEN no.2 H ≥77 oC Alarm (check lubricating oil cooler outlet
journal bearing temp.)
drain oil temp. trip by manual
Thrust bearing H ≥77 oC check lubricating oil cooler outlet temp.
drain oil temp. trip by manual
(front)
Thrust bearing H ≥77 oC check lubricating oil cooler outlet temp.
drain oil temp. trip by manual
(rear)
Stator winding H ≥ 130 oC Alarm
temperature
(U,V,W)
Generator H ≥ 52 oC Alarm
cooling air temp
Stator teeth (D) H ≥ 130 oC Alarm
temperature (TU
side)
Stator teeth (E) H ≥ 130 oC Alarm
temperature (SI
side)
BFP no.1 H ≥85 oC Alarm
bearing metal
temp.
BFP no.2 H ≥85 oC Alarm
bearing metal
temp.
BFP motor no.1 H ≥95 oC Alarm
bearing metal
temp.
BFP motor no.2 H ≥95 oC Alarm
bearing metal
temp.
CP motor no.1 H ≥95 oC Alarm
bearing metal
temp.
CP motor no.2 H ≥95 oC Alarm
bearing metal
temp.
BFP motor H ≥ 130 oC Alarm
phase (U,V,W)
winding temp.
CP motor phase H ≥ 130 oC Alarm
(U,V,W) winding
temp.
CCWP motor H ≥ 130 oC Alarm
phase (U,V,W)
winding temp.
LEVEL
Boiler drum level HH +254 mm MFT
H +127 mm Alarm
L -177 mm Alarm
LL -254 mm Trip PAF/MFT
Condenser level SV NWL=400 Condenser level control valve
H NWL+150 Alarm (condenser spil over valve open)
mm
Not H NWL+0 Condenser spill over close
L NWL-150 Alarm
mm
HH NWL+250 Alarm (urbin bypass val close)
mm
No.1 LP Heater SV NWL=132 No.1 LPH level control valve
level H NWL+50 mm Alarm
L NWL-50 mm Alarm
HH NWL+218 Alarm (no.1 LPH emergency drain valve,
mm no.1 LPH inlet/outlet/bypass valve)
No.2 LP Heater SV NWL=132 No.2 LPH level control valve
level H NWL+50 mm Alarm
L NWL-50 mm Alarm
HH NWL+218 Alarm (no.2 LPH emergency drain valve,
mm no.1 LPH inlet/outlet/bypass valve)
Deaerator tank SV NWL=2438 Deaerator level control valve
level H NWL+150 Alarm
mm
L NWL-300 Alarm
mm
HH NWL+250 Alarm (control deaerator drain valve, no.3
mm extraction check valve)
LL NWL-930 Alarm
mm BFP stop
No.4 HP Heater SV NWL=155 No.4 HPH level control valve
level H NWL+50 mm Alarm
L NWL-50 mm Alarm
HH NWL+245 Alarm (no.2 LPH emergency drain valve,
mm no.2 LPH inlet/outlet/bypass valve, no.4
extraction check valve)
No.5 HP Heater SV NWL=155 No.5 HPH level control valve
level H NWL+50 mm Alarm
L NWL-50 mm Alarm
HH NWL+245 Alarm (no.2 LPH emergency drain valve,
mm no.2 LPH inlet/outlet/bypass valve, no.4
extraction check valve)
Condenser water NWL=3965 From tank bottom
box level mm
L NWL-60 mm Contrl for priming of condenser water box
H NWL+100 Cont. for priming of condenser water box
mm
Lube oil tank L NOL-100 Alarm
level mm
Control oil tank L NOL-70 mm Alarm (control ol tank heater off)
level
Generator H 200 cc Alarm
cooling water
leakage
CCW stand pipe H NWL+1000 Stand pipe level control close
level mm
L NWL-1000 Stand pipe level control open
mm
LL NWL-1200 Alarm
mm
Turbine room H Pit Sump pump on
and condensate bottom+540
pit level mm
L Pit Sump pump off
bottom+190
mm
Turbine oil sump H Pit Sump pump on
pit level bottom+700
mm
L Pit Sump pump off
bottom+180
mm
LOW
Condensate SV 115 t/h Cont. condensate minimum flow valve
flow/SJAE outlet SV 374 t/h Max.flow control of CP
-- <264 t/h One of CP off, if two are operated
BFP discharge SV 220 t/h Max.flow control of BFP
flow H >160 t/h Minim flow valve close
L <70 t/h Minim flow valve open
Main steam flow range 120-372,9 t/h
VIBRATION
Turbine no.1 H ≥125 µm (P-P) Alarm
bearing shaft HH ≥250 µm (P-P) Alarm
vibration (x,y)
Turbine no.2 H ≥125 µm (P-P) Alarm
bearing shaft HH ≥250 µm (P-P) Alarm
vibration (x,y)
Generator no.1 H ≥125 µm (P-P) Alarm
bearing shaft HH ≥250 µm (P-P) Alarm
vibration (x,y)
Generator no.2 H ≥125 µm (P-P) Alarm
bearing shaft HH ≥250 µm (P-P) Alarm
vibration (x,y)
CP bearing H ≥80 µm (P-P) Alarm
vibration (x,y,A)
CP motor H ≥80 µm (P-P) Alarm
bearing vibration
(x,y,)
BFP no.1 bearing H ≥40 µm (P-P) Alarm
vibration (x,y,A)
BFP no.2 bearing H ≥40 µm (P-P) Alarm
vibration (x,y)
BFP motor H ≥40 µm (P-P) Alarm
bearing vibration
(x,y)

POSITION
Shaft position HH ± 1,0 mm Trip (mechanical thrust failer protection)
H ± 0,5 mm Alarm
Eccentricity H 70 micron Alarm
Expantion H +6 (rotor Alarm
differential long)mm
L -3 (rotor Alarm
short)mm
HH +7 (rotor Trip (manual)
long)mm
LL -4 (rotor Trip (manual)
short)mm
SPEED
Turbine speed HH 3300±30 rpm Trip (mechanical emergency governor)
(110±1%)
HH 3360 Alarm
(sensor) (112%)rpm Trip 2 out of 3 back up electrical over
range 2850-3150 Operating permissible speed
(95%-
105%)rpm
Range 400-1220 Do not hold
rpm
Range 1280-2850 Do not hold
rpm

Anda mungkin juga menyukai