Anda di halaman 1dari 5

Tugas Beton Pratekan

qSDL = 5 kN/m

Penampang
Parameter:
Mutu K 450

Mutu Tendon: ASTM A-Low Relaxation


GR-1725
fpu = 1725 Mpa
fpi = 0.7 fpu
fpe = 0.75 fpu

Tendon Post-Tension=
15 bh 7-wired standard
dim = 12.7 mm
As= 92.9 mm2
e= -18.00 cm
Relative Humidity= 75 %
Volume/Surface = 3

Hitung kehilangan gaya prategang akibat


A. Elastic Shortening
B. Creep
C. Shinkage
D. Steel Relaxation
E. Anchorage Slip

Jawab:
Mencari Inersia

Bangun No. L = 25 m
1 2 3
dimensi (cm) q = 5 kN/m
b 600 150 600 fpi = 1207.5 Mpa
h 180 700 200 fpe = 1293.75 Mpa
fc' = 37.35 Mpa
L1 = 108000.00 cm² fci' = 29.88 Mpa
L2 = 105000.00 cm²
L3 = 120000.00 cm²
A = 333000.00 cm²
Inersia
Ix1 = 517354387.2 cm4 W1= 1/12x600x1802= 1620000 mm3
Ix2 = 4506983432 cm4 W2= 1/12x150x7002= 6125000 mm3
Ix3 = 650838208 cm4 W3= 1/12x600x2002= 2000000 mm3
Inersia Total
Ix Total 5675176027.20 cm4 W Total 9745000 mm3

Mencari nilai Momen

Mselfweight = 391 kNm


Mterpusat = 62.5 kNm
Mtotal = 453 kNm

A Elastic Shortening

Ec = 4700 fc
= 28723.884
Es = 200000 Mpa
n = Es
Ec
= 200000
28723.884
= 6.9628467

Luas Strand = 92.9 mm2


Aps = 1393.5 mm2 13.94 cm2

Penarikan Pertama
Pinitial = Aps x fpi
= 10095908 N
Peffective = Aps x fpe
= 18028.406 N

Kehilangan gaya prategang pada tendon 1 adalah sebesar:


n x Pi
ES=
Ac
6.96 x 10095907.5
ES= = 211.10 MPa
333000.00

Penarikan Kedua

Pinitial= gaya prategang pada kabel lain x (fpi x Aps)


Pinitial= 8413256.3 N

Kehilangan gaya prategang pada tendon 2 adalah sebesar:

n x Pi
ES=
Ac
6.96 x 8413256.25
ES= = 175.92 MPa
333000.00

Penarikan Ketiga

Pinitial= gaya prategang pada kabel lain x (fpi x Aps)


Pinitial= 6730605 N

Kehilangan gaya prategang pada tendon 2 adalah sebesar:

n x Pi
ES=
Ac
6.96 x 6730605
ES= = 140.73 MPa
333000.00

Kehilangan gaya prategang pada tendon 3 sebesar

(∑▒𝐸𝑆)/7
ES =
527.75
=
7
= 75.4

Presentase Kehilangan = 75.39 = 6.244 %


1208

B Creep (Rangkak)
Aps = 1393.5 mm2 13.94 cm2
Pinitial = Aps x fpi
= 1682651.25 N
Eksentrisitas beton, e = 390 mm
Tegangan beton ditengah bentang balok

Pinitial Pinitial.e
fc = +
A W
1682651.3 656233987.5
= +
333000.00 9745000.00
= 72.3935903894 N/mm2

εce= 35x10-6 asumsi


φ= 1.6 asumsi
CR= εce x fc x Es= 506.76 MPa

Persentase kehilangan prategang terhadap tegangan awal tendon :

CR 100 % 41.97 %
%CR=
fpi

Cara koefisien rangkak

Es
CR = φ fc
Ec
200000
= 115.82974
28723.88
= 806.50476 Mpa

Persentase kehilangan prategang terhadap tegangan awal tendon :

CR 100 % 66.79 %
%CR=
fpi

C Shrinkage (Susut atau Penyusutan)

V/S= 3 cm = 30 mm
Ksh= 1

εsh=
Sh= Ksh Es εsh

εsh= 8.2x10-6 (1-0.024(30))(100-75)= 0.0000574


Sh= 11.48 MPa

D Steel Relaxation ( Relaksasi Baja )


Menggunakan metode ACI-ASCE untuk menghitung kehilangan yang diakibatkan relaksasi.
Metode ini menggunakan kontribusi terpisah antara perpendekan elastis, rangkak, dan susut
dalam evaluasi kehilangan yang diakibatkan relaksasi tegangan, dengan menggunakan
persamaan :
Menggunakan metode ACI-ASCE untuk menghitung kehilangan yang diakibatkan relaksasi.
Metode ini menggunakan kontribusi terpisah antara perpendekan elastis, rangkak, dan susut
dalam evaluasi kehilangan yang diakibatkan relaksasi tegangan, dengan menggunakan
persamaan :
RE = [Kre - J(SH+CR+ES)]C

Kre = 4630
J = 0.037

fpi/fpu = 0.7
C = 0.75
Untuk kawat relaksasi rendah dengan nilai fpi/fpu sama dengan 0.7
RE = [Kre - J (SH+ + CR + ES)] C
RE [
= 4630 − 0.037 11.48 (+ 506.76 + 75.39) ] 0.75
RE = 3456.03 MPa

E Anchorage Slip ( Slip pada Angkur )

Modulus Elastisitas, Es = 200000 MPa


Slip di pengangkuran, ΔA = 2.5 mm (assumption)
Panjang Tendon, L = 25 m = 25000 mm

ΔA . Es 500000 = 20 MPa
ΔfpA= =
L 25000