Anda di halaman 1dari 10

Project TSEL Balnus (Seba-Eilogo-Tenau)

LINKPlanner PTP Proposal Report


18 January 2019
Ahmad Junaidi
Organization: PT Wave Communication indonesia
Phone: 085271741176
Email: aahmadjunaidi@gmail.com

center = 10.38285S 122.69187E

-50

Tenau
kilometers

0
Seba
Eilogo

50

Cambium Networks - LINKPlanner


-100 -50 0 50 100
kilometers

Page 1 of 10
Table of Contents

1. Project Summary 3
2. Eilogo to Tenau 6
3. Seba to Eilogo 8
Disclaimer 10

18 January 2019 2
LINKPlanner version 4.8.5 Proposal Report
1. Project Summary

Project: TSEL Balnus (Seba-Eilogo-Tenau)

General Information
Customer Name
Company Name
Address
Phone
Cell Phone
Email

18 January 2019 3
LINKPlanner version 4.8.5 Proposal Report
Project TSEL Balnus (Seba-Eilogo-Tenau) - 1. Project Summary

Network Map

center = 10.38285S 122.69187E

-150

-100

-50

Tenau
kilometers

0
Seba
Eilogo

50

100

150

Cambium Networks - LINKPlanner


-100 -50 0 50 100
kilometers

18 January 2019 4
LINKPlanner version 4.8.5 Proposal Report
Project TSEL Balnus (Seba-Eilogo-Tenau) - 1. Project Summary

Link name Max aggregate IP


Product Local antenna Remote antenna throughput
Eilogo to Tenau Cambium Cambium
Networks 4ft Networks 4ft
Dual-Polar Dual-Polar
Parabolic Parabolic
PTP670 RDH4505 RDH4505 0.00 Mbps
Seba to Eilogo Cambium Cambium
Networks 2ft Networks 2ft
Dual-Polar Dual-Polar
Parabolic Parabolic
PTP670 RDH4503 RDH4503 198.46 Mbps

Bill of Materials : PTP Network


Part Number Qty Description
01010419001 26 Coaxial Cable Grounding Kits for 1/4" and 3/8" Cable

C000065L007 4 LPU and Grounding Kit (1 kit per ODU)

C050067H008 2 PTP 670 Connectorized END with AC+DC Enhanced Supply (ROW - U.S. Line
Cord).
Kit includes ODU, power supply, mounting bracket and US line cord

C050067H014 2 PTP 670 Connectorized END with AC+DC Enhanced Supply (ROW - EU Line
Cord).
Kit includes ODU, power supply, mounting bracket and EU line cord
EW-E4PT6XX-WW 4 PTP 650/670 Extended Warranty, 4 additional years (per END)
RDH4503 2 5.25-5.85 GHZ, 2-FT (0.6M), WITH FINE ADJUSTMENTS
RDH4505 2 5.25-5.85 GHZ, 4-FT (1.2M), DUAL-POL, H-POL & V-POL

WB3176 4 328 ft (100 m) Reel Outdoor Copper Clad CAT5E (Recommended for PTP)

18 January 2019 5
LINKPlanner version 4.8.5 Proposal Report
Eilogo to Tenau
Equipment: Cambium Networks PTP670 Connectorized
Cambium Networks 4ft Dual-Polar Parabolic Cambium Networks 4ft Dual-Polar Parabolic
RDH4505 @ 72 m RDH4505 @ 72 m

Eilogo Tenau
Height Above Sea Level (meters)

Height Above Sea Level (meters)


350 350
325 325
300 300
275 275
250 250
225 225
200 200
175 175
150 150
125 125
100 100
75 75
50 Cambium Networks - LINKPlanner 50
25 25
0 0
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180
Range on path (kilometers)

Performance to Eilogo Performance to Tenau


Mean IP 0.0 Mbps 0.0 Mbps
IP Availability 0.0000 % for 1.0 Mbps 0.0000 % for 1.0 Mbps

Link Summary
Link Length 186.427 km System Gain 186.42 dB
Band 5.8 GHz System Gain Margin -53.68 dB
Regulation Other Mean Aggregate Data Rate 0.0 Mbps
Modulation Adaptive Annual Link Availability 0.0000 %
Bandwidth 20 MHz Annual Link Unavailability 365.0 days/year
Total Path Loss 240.10 dB Prediction Model ITU-R

18 January 2019 6
LINKPlanner version 4.8.5 Proposal Report
Project TSEL Balnus (Seba-Eilogo-Tenau) - 2. Eilogo to Tenau

Performance Charts

Performance to Eilogo Performance to Tenau


99.99999% 99.99999%

99.9999% 99.9999%

99.999% 99.999%
Availability

Availability
99.99% 99.99%

99.9% 99.9%

99.0% 99.0%

90.0% 90.0%

0.0% 0.0%
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Capacity (Mbps) Capacity (Mbps)

Climatic Factors, Losses and Standards


dN/dH not exceeded for 1% -104.46 N Gaseous Absorption
of time units/km Loss 2.17 dB
Area roughness 110x110km 23.01 metre Link Type Non Line-of-Sight
Geoclimatic factor 6.94e-05 Excess Path Loss 84.80 dB
Fade Occurrence Factor (P0) 7.42e+00 Atmospheric Gasses ITU-R P.676-7, ITU-R P.835-4
Path inclination 1.18 mr Diffraction Loss ITU-R P.526-10
Value of K Exceeded for
99.99% (ke) 0.99 Propagation ITU-R P.530-12
Excess Path Loss at ke 95.33 dB Rain Rate ITU-R P.837-5
0.01% Rain rate 85.21 mm/hr Refractivity Index ITU-R P.453-9
Free Space Path Loss 153.13 dB

Bill of Materials
Part Number Qty Description
01010419001 14 Coaxial Cable Grounding Kits for 1/4" and 3/8" Cable

C000065L007 2 LPU and Grounding Kit (1 kit per ODU)


C050067H014 2 PTP 670 Connectorized END with AC+DC Enhanced Supply (ROW - EU Line
Cord).
Kit includes ODU, power supply, mounting bracket and EU line cord
EW-E4PT6XX-WW 2 PTP 650/670 Extended Warranty, 4 additional years (per END)
RDH4505 2 5.25-5.85 GHZ, 4-FT (1.2M), DUAL-POL, H-POL & V-POL

WB3176 2 328 ft (100 m) Reel Outdoor Copper Clad CAT5E (Recommended for PTP)

18 January 2019 7
LINKPlanner version 4.8.5 Proposal Report
Seba to Eilogo
Equipment: Cambium Networks PTP670 Connectorized
Cambium Networks 2ft Dual-Polar Parabolic Cambium Networks 2ft Dual-Polar Parabolic
RDH4503 @ 68 m RDH4503 @ 68 m
340 340
320 Seba Eilogo 320
Height Above Sea Level (meters)

Height Above Sea Level (meters)


300 300
280 280
260 260
240 240
220 220
200 200
180 180
160 160
140 140
120 120
100 100
80 80
60 60
40 40
20 Cambium Networks - LINKPlanner 20
0 0
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5
Range on path (kilometers)

Performance to Seba Performance to Eilogo


Mean IP 99.2 Mbps 99.2 Mbps
IP Availability 100.0000 % for 1.0 Mbps 100.0000 % for 1.0 Mbps

Link Summary
Link Length 8.590 km System Gain 173.76 dB
Band 5.8 GHz System Gain Margin 47.28 dB
Regulation Argentina
(Private) Mean Aggregate Data Rate 198.5 Mbps
Modulation Adaptive Annual Link Availability 100.0000 %
Bandwidth 20 MHz Annual Link Unavailability 0 secs/year
Total Path Loss 126.48 dB Prediction Model ITU-R

18 January 2019 8
LINKPlanner version 4.8.5 Proposal Report
Project TSEL Balnus (Seba-Eilogo-Tenau) - 3. Seba to Eilogo

Performance Charts

Performance to Seba Performance to Eilogo


99.99999% 99.99999%

99.9999% 99.9999%

99.999% 99.999%
Availability

Availability
99.99% 99.99%

99.9% 99.9%

99.0% 99.0%

90.0% 90.0%

0.0% 0.0%
0 20 40 60 80 100 120 140 160 0 20 40 60 80 100 120 140 160
Capacity (Mbps) Capacity (Mbps)

High Capacity, assumes there is no load in the other direction

Symmetrical Capacity, assumes a saturated load in the other direction

Climatic Factors, Losses and Standards


dN/dH not exceeded for 1% Gaseous Absorption
of time -97.32 N units/km Loss 0.10 dB
Area roughness 110x110km 19.93 metre Link Type Line-of-Sight
Geoclimatic factor 7.02e-05 Excess Path Loss 0.00 dB
Fade Occurrence Factor (P0) 3.47e-05 Atmospheric Gasses ITU-R P.676-7, ITU-R P.835-4
Path inclination 26.47 mr Diffraction Loss ITU-R P.526-10
Value of K Exceeded for
99.99% (ke) 0.40 Propagation ITU-R P.530-12
Excess Path Loss at ke 0.00 dB Rain Rate ITU-R P.837-5
0.01% Rain rate 84.76 mm/hr Refractivity Index ITU-R P.453-9
Free Space Path Loss 126.38 dB

Bill of Materials
Part Number Qty Description
01010419001 12 Coaxial Cable Grounding Kits for 1/4" and 3/8" Cable

C000065L007 2 LPU and Grounding Kit (1 kit per ODU)


C050067H008 2 PTP 670 Connectorized END with AC+DC Enhanced Supply (ROW - U.S. Line
Cord).
Kit includes ODU, power supply, mounting bracket and US line cord
EW-E4PT6XX-WW 2 PTP 650/670 Extended Warranty, 4 additional years (per END)
RDH4503 2 5.25-5.85 GHZ, 2-FT (0.6M), WITH FINE ADJUSTMENTS

WB3176 2 328 ft (100 m) Reel Outdoor Copper Clad CAT5E (Recommended for PTP)

18 January 2019 9
LINKPlanner version 4.8.5 Proposal Report
Disclaimer

Cambium Networks assumes no responsibility for the accuracy of the information produced by the Cambium LINKPlanner. Reference to
products or services which are not provided by Cambium Networks is for information purposes only and constitutes neither an endorsement
nor a recommendation. All information provided by the Cambium LINKPlanner is provided without warranty of any kind, either expressed or
implied.

All product or service names are the property of their respective owners. © Cambium Networks. 2019

18 January 2019 10
LINKPlanner version 4.8.5 Proposal Report

Anda mungkin juga menyukai