Anda di halaman 1dari 9

2019

P T S E M E N B AT U R AJ A
(PERSERO) TBK

KALIBRASI JEMBATAN TIMBANG 80 TON


PALEMBANG
DATA PERALATAN ELECTRICAL

NO NAMA ALAT 28.000


SPESIFIKASI
28.000 56.000
28.000 JUMLAH
16.322
15.45 16.322
31.787
1 DIGITAL WEIGHING INDICATOR MERK : RICE LAKE INPUT VOLTAGE : 220 VAC 50 HZ DC OUTPUT 1 BUAH
VOLTAGE : 24 VDC EXITATION 12 VDC ANALOG SINGNAL
OUTPUT RANGE -45MV +45MV COMUNICATION PORT RS 232

28 672 1344
2 SENSOR LOAD CELL 13 : SCHENCK GERMANY
MERK 620 6 BUAH
287
TYPE : RTN 33T C3 E.MIN : 33TON E.LIM: 56TON CN : 2,85MV/V
V.MIN:1,65KG

3 JUNCTION BOX TERMINAL MERK : RICE LAKE 1 INPUT 6 OUTPUT TERMINAL 1 BUAH

4 ELASTOMER MERK SCHENK VEN 33 with order nos. D 725575.02, rated capacity 6 BUAH
33t, weight 14kg
5 KABEL CONTROL 1,5mm x 7 - -+ 30 METER

93.5 97.31 97.31


6 KABEL GROUNDING 50mm - -+ 10093.5
METER

104 100 102

93.5 107 93.5 99.

PT Semen Baturaja (Persero) Tbk 1


KALIBRASI JEMBATAN TIMBANG

LANGKAH AWAL

1. CLEANING
BERSIHKAN SELURUH AREA JEMBATAN TIMBANG DARI COATING/
KOTORAN UNTUK MEMUDAHKAN DAN KENYAMANAN
89 88.01 87.30 DALAM PROSES
KALIBRASI
89JJ

36 38 37

36

PT Semen Baturaja (Persero) Tbk 2


KALIBRASI JEMBATAN TIMBANG

2. LEVELING PLATFORM
PASTIKAN TIMBANGAN / PLATFORM HARUS LEVEL

Dengan Teknik pengukuran selang plastik berisi air

PT Semen Baturaja (Persero) Tbk 3


KALIBRASI JEMBATAN TIMBANG

3. CHECK KOMPONEN LISTRIK


PASTIKAN LOAD CELL, INDIKATOR, JUNCTION BOX BERFUNGSI DENGAN
BAIK ATAU TIDAK RUSAK
- Check load cell dengan battery 9VDC sebagi input tegangan load cell,
contoh
Load Input tahanan Output tahanan Input tegangan Output tegangan
cell (4480Ω ± 50Ω) (4010Ω ± 10Ω) (BATTERTY 9VDC) (NORMAL 0,1VDC)
SESUAI SERTIFICATE SESUAI SERTIFICATE DATA
DATA LOAD CELL LOAD CELL

1 4480 4010 9 VDC 0,0 VDC


2 3921 3994 9 VDC 0,8 VDC
3 4490 4000 9 VDC 0,1 VDC
4 4470 4010 9 VDC 0,1 VDC
5 4460 4010 9 VDC 0,1 VDC
6 4450 4002 9 VDC 0,0 VDC
Dasar Teknik pengukuran by TURMAN ( Teknisi Schenck Process ) Planner Weigher PPG

PT Semen Baturaja (Persero) Tbk 4


KALIBRASI JEMBATAN TIMBANG

- Check load cell dengan test beban per load cell


CONECT HANYA 1 LOAD CELL YANG INGIN DI TEST BEBAN PADA JUNCTION BOX,
KEMUDIAN CATAT HASIL NO LOAD DAN LOAD,
SETELAH ITU, LEPAS KABEL LOAD CELL YANG TELAH DI TIMBANG,
KEMUDIAN CONECT KE LOAD CELL SELANJUTNYA

LOAD TEST WEIGHT NO LOAD LOAD


CELL ( MOBIL XENIA 1427 KG ) (normal : ada (normal : ada
nilai terbaca) nilai terbaca)
1 1427 KG 12460 KG 12720 KG
2 1427 KG XXXXXX XXXXXXX
3 1427 KG 13840 KG 16440 KG
4 1427 KG 13840 KG 16440 KG
5 1427 KG 25720 KG 25760 KG
6 1427 KG 25720 KG 25760 KG

PT Semen Baturaja (Persero) Tbk 5


KALIBRASI JEMBATAN TIMBANG

4. KALIBRASI (APABILA KETIGA TAHAP DIATAS TELAH DILAKUKAN)

A. KALIBRASI ZERO

1. PASTIKAN JEMBATAN TIMBANG KOSONG


2. PADA RICE LAKE INDIKATOR :
TEKAN MENU ENTER
3. PILIH CONFIGURATION ENTER
4. PILIH SCALE ENTER
5. PILIH SCALE 1 ENTER
6. TEKAN KIRI SAMPAI MUNCUL CALIBRATION ENTER
7. W ZERO ( DEAD LOAD CALIBRATION ) ENTER
8. TEKAN F2 CALIBRATE
9. W VAL ENTER
10. SAVE & EXIT

PT Semen Baturaja (Persero) Tbk 6


KALIBRASI JEMBATAN TIMBANG

A. KALIBRASI SPAN

1. PASTIKAN JEMBATAN TIMBANG KOSON


2. PADA RICE LAKE INDIKATOR :
TEKAN MENU ENTER
3. PILIH CONFIGURATION ENTER
4. PILIH SCALE ENTER
5. PILIH SCALE 1 ENTER
6. TEKAN KIRI SAMPAI MUNCUL CALIBRATION ENTER
7. W VAL ( TEST WEIGHT VALUE ) ` ENTER
8. MASUKAN NILAI BEBAN ( TEST WEIGHT) ENTER
9. W SPAN ( TEST WEIGHT SUDAH DI ATAS JEMBATAN TIMBANG ) ENTER
10. TEKAN CALIBRATE (F2)
11. SAVE & EXIT

PT Semen Baturaja (Persero) Tbk 7


Terima Kasih

PT Semen Baturaja (Persero) Tbk