Purpose:
This laboratory test is performed to determine the relationship between the moisture content
and the dry density of a soil for a specified compactive effort. The compactive effort is the
amount of mechanical energy that is applied to the soil mass. Two types of compaction tests
are routinely performed: (1) The Standard Proctor Test, and (2) The Modified Proctor Test.
Reference:
ASTM D 698 - Standard Test Methods for Laboratory Compaction
ASTM D 1557 - Standard Test Methods for Laboratory Compaction
Equipment:
• Proctor mould with a detachable collar assembly and base plate.
• Drop rammer
a) Standard Test: 24.5N rammer falling 0.305m
b) Modified Test: 44.5N rammer falling 0.46m
• Sample Extruder.
• A sensitive balance.
• Straight edge.
• Squeeze bottle
• Mixing tools such as mixing pan, spoon, trowel, spatula etc.
• Moisture cans.
• Drying Oven
• 10.#4 sieve,
• Graduated cylinder,
Test Procedure
(1) Depending on the type of mold you are using obtain a sufficient quantity of air-dried soil
in large mixing pan. For the 101,6mm mold take approximately 4,5kg, and for the 152,4mm
mold take roughly 6,75kg. Pulverize the soil and run it through the # 4 sieve.
(2) Determine the weight of the soil sample as well as the weight of the compaction mold with
its base (without the collar) by using the balance and record the weights.
(3) Compute the amount of initial water to add by the following method: (a) Assume water
content for the first test to be 8 percent. (b) Compute water to add from the following
equation:
(7) The soil should completely fill the cylinder and the last compacted layer must extend
slightly above the collar joint. If the soil is below the collar joint at the completion of the
drops, the test point must be repeated. (Note: For the last layer, watch carefully, and add more
soil after about 10 drops if it appears that the soil will be compacted below the collar joint.)
(8) Carefully remove the collar and trim off the compacted soil so that it is completely even
with the top of the mold using the trowel. Replace small bits of soil that may fall out during
the trimming process (See Photo F).
(9) Weigh the compacted soil while it’s in the mold and to the base, and record the mass (See
Photo G). Determine the wet mass of the soil by subtracting the weight of the mold and base.
(10) Remove the soil from the mold using a mechanical extruder (See Photo H) and take soil
moisture content samples from the top and bottom of the specimen (See Photo I). Fill the
moisture cans with soil and determine the water content.
(11) Place the soil specimen in the large tray and break up the soil until it appears visually as
if it will pass through the # 4 sieve, add 2 percent more water based on the original sample
mass, and re-mix as in step 4. Repeat steps 5 through 9 until, based on wet mass, a peak value
is reached followed by two slightly lesser compacted soil masses.
Calculations:
(3) Compute the dry density using the wet density and the water content determined in step 1.
Use the following formula:
where: w = moisture content in percent divided by 100, and ρ = wet density in grams per cm3.
(4) Compute the dry unit weight in kN per m3 .
(5) Plot the dry unit weight values on the y-axis and the moisture contents on the x-axis. Draw
a smooth curve connecting the plotted points.
(6) On the same graph draw a curve of complete saturation or “zero air voids curve”. The
values of dry density and corresponding moisture contents for plotting the curve can be
computed from the following equation:
where:
yd= dry unit weight of soil (kN/m3)
Gs = specific gravity of the soil being tested (assume 2.70 if not given)
yw = unit weight of water (kN/m3)
S = moisture content in percent for complete saturation.
(7) Identify and report the optimum moisture content and the maximum dry unit weight..
Reference:
• AASHTO T 191 (Sand Cone)
Equipment
• Sampling tools - hammer, chisel, trowel, large spoon, banister brush.
• Containers - two 2.3 L size mason jars for which the tare weights are known.
• Balance - 0.1 g accuracy
• Sand Cone Density Apparatus(Figure1) - consisting of a double cone assembly having
a cylindrical valve between the cones with an orifice 12.7 mm in diameter. The upper
conewill be large enough to serve as a hopper to hold the density sand.
• Density Sand - prepare a supply of air dried clean flowing sand which passes the 2.00
mm sieve and is retained on the 900 mm sieve. Thoroughly mix and preweigh 5000 g
samples and store in a clean dry place.
Procedure
1. Select the site to be tested at random or where sample for proctor has been taken.
2. Scrape smooth and remove all loose material at the location to be tested.
3. Start a small hole in the centre with a hammer and chisel.
4. Carefully enlarge the hole outwards and downwards with small hand tools until
sufficient material has been removed to fill the two 2.3 L mason jars.
5. Exercise extreme care in removing the material so as not to cause a disturbance to
surrounding material. Do not project the hole below the level of the material to be
tested.
6. Place all the material removed from the hole in the mason jars except Stone particles
larger than 18 mm. These stones will be replaced in the hole during the volume
measurement with density sand. The sealed jars will be taken to the lab and weighed
to the nearest gram and the tare weight subtracted. The result will be recorded as
"weight of material removed."
7. Carefully place and centre the sand cone device over the test hole with the valve
closed.
8. Place the 5000 g of density sand into the storage hopper of the sand cone device.
9. Turn on the valve.
10. If stone particles are to be replaced in the hole, allow a small quantity of sand to run
into the hole, close the valve, lift the apparatus, and partially imbed these particles into
the sand. Replace the device, turn on the valve, allow the sand to run until the test hole
and funnel are completely filled, and turn off the valve.
11. Remove the apparatus and remove the sand from the test hole and place in a large
cloth bag along with other used sand for later reclaiming.
12. Weigh the unused sand in the hopper to determine the amount of sand used in the test.
This weight of sand will be used to obtain the volume of hole and funnel.
13. Remove the soil cement mixture from the two mason jars and mix thoroughly together
and obtain a representative sample for moisture determination.
14. Place sample in a suitable tared pan and weigh.
15. Dry sample carefully to a constant weight.
16. Weigh sample and pan after cooling.
17. The difference between the wet and dry weights will be recorded as "weight of
moisture" and dry weight less weight of pan will be recorded as "weight of dry
sample."
Calculation :
W4=W2/(1+w/100)
V=(W1 –W3- Wc)/y d(sand)
y d=W4/V
Data For Sand Cone Test:
Volume Wet Dry Unit Dry Unit Unit Dry Unit Moisture
of Hole Mass Mass Density Density Weight Weight Content
(cm3) (g) (g) (g/cm3) (g/cm3) (kN/m3) (kN/m3) w (%)
CONCLUSION:
Modified proctor : The values of Yd plotted against the corresponding moisture contents to
obtain the max. dry unit weight and the optimum moisture content for soil. From modified
proctor Dry Unit Weight Curve we obtained the values as; ydmax=18,52kN/m3 and
WOPT=9,8%. At that graph also we see Yzav (zero air void) which S=100% , is only place on
right of basic curve.
İf the data obtained from Modified proctor and Sand cone test are compared:
For test 1 :
Relative compaction=(17,17/18,52)*100=92,7%
For test 1:
Relative compaction=(16,88/18,52)*100=91,1%
So the required specifications for relative compaction.are provided
For test 1 water content provides the required specifications .But water content in the test 2 a
little over of max.Water content(13,8%). So , wait a little bit of water to dry.
Standard proctor test: The values of Yd plotted against the corresponding moisture contents
to obtain the max. dry unit weight and the optimum moisture content for the soil. From
standard proctor curve we obtained the values as; Ydmax=17,20kN/m3 and WOPT=15,1% . At
that graph also we see Yzav (zero air void) which S=100% , is only place on right of basic
curve.