DESIGN OF HYDRO POWER DESANDER

Dam Crest Elev.= 140.9


Bot. Desander Elev.= 138.2

SIZE OF GRAIN
GROSS HEAD= 52.3 m Intake Gate width = 0.8 m HEAD (m) (D)(mm)
QP= 3.48 m3/s 20-50 0.3
QT= QP+QF 50-100 0.25
QT = 4.176 m3/s 100-300 0.2
V=a√d d= 0.2
a= 44
V= 0.197 m/s
use V= 0.3 m/s (.3-.6)mean flow velocity
2
AT= 13.92 m Area of Tank Required
D= 3.5 m Depth of Tank
B= 3.977143 m
say B= 4 m Width of Tank

υ= 0.1 m/s fall Velocity


L≥ (V/u)*D
L= 10.5 min. length of tank
Ls= 32 (m) depth of tank

checking settling time:


t= D/B
t= 1.142857 sec
Discharge during "t" period
V= Qt
V= 4.772571 m3 FINAL DIMENSION: Transition length:
B= 4 m width α= 14.5 deg
Volume capacity of basin: SAFE D= 3.5 m depth l= 6.19 m
V= hbL L= 32 m length l≤ 12 m SAFE
V= 448 m3 L/B= 8 ≥4 limit (8to10)recommended

USING 97% REMOVAL RATION VALIKANOV'S METHOD


λ= 1.5
L= λ 2 V 2 ( √h-.2) 2
7.51w 2
L= 0 m

CONSIDERING RETARDING EFFECT OF TURBULENT


a= 0.132/h
a= 0.037714
w'= aV
w'= 0.00743 m/s

L= hV/w-w'
L= 7.45 m
say L= 11.175 m
Ls= 22.35 m

Volume capacity:
V= hbL
V= 1430.4 m3

DESANDER OVERFLOW DESIGN


DESIGN OF DESANDER FLUSHING
Qf = 0.20Qd
Qf = inflow volume of submerged orifice (m3/s) Qf = 0.696 m3/s
Qf = Ai x Cv x Ca x (2xgxH)^0.5 Assume V= 3 m/s
Ai = bi x (dh + hi), dh = 0.10-0.15m Areq.= 0.23 m2
Cv = coefficient of velocity = 1/(1+f) USED D= 0.5 m
f = coefficient of inflow loss AREA= 0.2 m2
Ca = 0.6 approximately Design Velocity= 3.54 m/s
INTAKE SIZE:
w= 0.6 m f= 0.5
d= 0.6 m Cv= 0.666667
Ai= 0.36 m H= 0.9 m
hi= 0.45 m
dh = 0.15 m
Qf = C x Bsp x hsp ^1.5 Assume value
Qf = 0.363 m3/s
hsp = 0.3 m Qd= C*Bsp*hsp^1.5
C= 1.8 Constant Bsp= 11.766 m
Bsp = 1.23 m say Bsp= 1.5 m
USE Bsp= 2 m
OVERFLOW SIZE:
2 x 0.3 m

DESIGN OF HEAD TANK

Vsc = As*dsc = B*L*dsc


where:
Vsc= 69.6 m3/s Head tank capacity (10 to 20 times the design discharge)
dsc= ho/2 m ,ho = height of head race
dsc= 3.6 m
B= 2 m hc= 0.697601
L= 9.667 m
say L= 29.001 m
Check Vsc= 169.3658