TROUBLESHOOTING ALARM

2G HUAWEI
1. Sensor Failure
Check Cable From Cabinet Battrey di Com-in ke PMU di Com-485)
2. Inter System Control Right Conflict
PMU 2G dan 3G tidak Singkron Cabut wmpt jika 3G blm On-Air
 SET BTSLOADCTR
By Index BTS Index
Control Plag NO Efect NO
Self Version Software 2G Peer Version Software 3G
2G Version BTS3000V100R009C00SP56
3G Version V200R011C01SPC200
2.1. Alarm TCU
LST BTSDHEUBP
Check connect port no apabila di 1 ganti dgn di 0
Example: SET BTSDHEUBP: IDTYPE=BYID, BTSID=111, CN=0, SRN=8, SN=0,
CFGFLAG=YES, MPN=0;
Lalu remove : RMV BTSBRD: IDTYPE=BYID, BTSID=111, CN=0, SRN=8, SN=0;
Lalu add lagi: ADD BTSBRD: IDTYPE=BYID, BTSID=111, CN=0, SRN=8, SN=0, BT=TCU;
2.2 Inter-System Board Object Configuration Conflict
LST BTSMUABP
SET BTSMUABP
SET BTSFMUABP: IDTYPE=BYID, BTSID=156, CN=0, SRN=11, SN=0, CFGFLAG=YES,
MPN=0, ADDR=15
2.3 ADD Smoke and Water Alarm (Indoor)
SET BTSDEMUBP
SET BTSDEMUBP: IDTYPE=BYID, BTSID=201, CN=0, SRN=40, SN=0, CFGFLAG=YES,
SASE=WIDISABLE-0&SMDISABLE-0&IMDISABLE-1&GMDISABLE-1;
3. Inter System Monitoring Device Parameter Temperature
 SET BTSDHEUBP
By Index BTS Index
Cabinet 0 Subrack 8
Slot No 0 Board YES
Temp 72
4. Untuk Indoor Ga perlu PMU,PSU1,PSU2,PSU3 Kita Delete Biar ga Alarm.
Kita Harus Inget !!!
Slot O >> PMU
1 >> PSU 1
2 >> PSU 2
3 >> PSU 3
Sub Rack 7
Cabinet O (Untuk Indoor Selalu O)
 RMV BTSBRD
By Index BTS Index
Cabinet O Sub.Rack 7
Slot No O,1,2,3 (Kita urut dari slot 3 atau sebaliknya)
5. Monitoring Device Link Failure
Check urutan Wairing Cable UPEU,PMU,FMUA,HPMI)
Jika Tidak Berhasil RESET BTS matikan Power BTS
6. Not Get Administratif Right
Di Site ada yang connect local ke BTS,Mereka Harus Logut dari BTS
7. Site Tidak Bisa di Aktifkan (MAIO)
LST BTS GTRXCHANHOP
SET BTS GTRXCHANHOP
8. Monitoring Status Merah Tidak Bisa Test Call
Reset GRFU
Reset BTS seluruhnya
LST GTRXDEF (Untuk lihat TRx power level)
9. SRAN CUSTOM
Alarm BTS belum di Create d BCS-nya

10. Configure Alarm BTS OUTDOOR


ALARM OUTDOOR
Normaly Closed
Phase Failur, Arester Fail, OBL Fail
Normaly Open
Genset 1 Run, Genset 2 Run, Fuel Empty, Hidrogen Faulty
11. Configure Wairing Alarm INDOOR

NB; Untuk Indoor Buglar Alarm tidak di gunakan karena sudah ada Door Open dari pintu Selter
Dif Switch SW_BKE no 4 Kita matikan agar tidar ada Alam Buglar
12. Lock Sector BTS
Device Manager Click kanan Sector yang mau di lock pilih “Modify administrative
status”Kemudian rubah status “UNLOCK” menjadi “LOCK