BASE DE DISEÑO DEL PROCESO

INCLUIR FORMATO DE CONTROL DE DOCUMENTOS


INGENIERIA BASICA
BASES DE DISEÑO DE PROCESO

CONTENIDO

(1)
C= 150, criteria were taken from API RP 14E.
(2)
Pressure drop depends on hydraulic performance of the relief network.
All lines are sizing with additional 10% of flow as design margin.
INGENIERIA BASICA
BASES DE DISEÑO DE PROCESO

1. OBJETO

The objective of this document is to outline design criteria used in the development of
the Engineering of the facilities for dehydrating, measuring and delivering natural gas to
the Venezuela Gas Pipeline.

2. DESCRIPCIÓN DEL PROYECTO

del sistema de transporte del gasoducto Gibraltar-Bucaramanga, localizado en el sector


comprendido entre el municipio de Toledo (Campo Gibraltar) en el Departamento de
Norte de Santander y el municipio de Bucaramanga en el Departamento de Santander,
para una longitud aproximada de 172 kilómetros.

2.1. ABBREVIATIONST
ASME: American Society of Mechanical Engineers
API: American Petroleum Institute
NFPA: National Fire Protection Association
NACE: National Association of Corrosion Engineers

2.2. GENERAL INFORMATION

Client:
Project name:
Location:

2.2.1. DESIGN CAPACITY

The design capacity at 1,200 psig for the existing main installations or process units is
shown:

(1)
C= 150, criteria were taken from API RP 14E.
(2)
Pressure drop depends on hydraulic performance of the relief network.
All lines are sizing with additional 10% of flow as design margin.
INGENIERIA BASICA
BASES DE DISEÑO DE PROCESO

2.2.2. REFERENCE DOCUMENTS

The scope of work to be developed in this project will be in accordance with the
document “BID Document for Detailed Engineering Contract”. Rev. B1 issued for
Quotations on 15/01/07.

2.2.3. LEGAL REQUIREMENTS, APPLICABLE CODES AND STANDARDS

The laws, codes, standards and specifications to be applied, are mentioned in the
following sections, according to the specific engineering discipline.

2.2.4. MEASUREMENT UNITS

The following measurement units are used:


Length (Short) ft ( ’ ), inches ( ” ),
Length (Long) miles (mi)
Diameter inches ( ” )
Weight (Mass) pounds (lb)
Temperature Fahrenheit degrees (ºF)
Absolute pressure psia
Manometer pressure Psig
Liquid, gas volume bbl, US gal, ft³
Density lb/ft3
Liquid flow BPD, gpm
Gas flow MMSCFD, SCFM
Heat BTU
Power hp, KW, KVA
Viscosity cP, cSt
Speed ft/s, mph
Electrical current A
Angle Degree (º)
Frequency Hz
Voltage V
Electrical resistance 

(1)
C= 150, criteria were taken from API RP 14E.
(2)
Pressure drop depends on hydraulic performance of the relief network.
All lines are sizing with additional 10% of flow as design margin.
INGENIERIA BASICA
BASES DE DISEÑO DE PROCESO

2.2.5. SITE CONDITIONS

Site Elevation 5 ft Above Sea Level


Temperature
Maximum 95.0 ºF
Minimum 80.6 ºF
Relative Humidity
Maximum 81 %
Minimum 64 %
Average 73 %
Fall rain
Annual average 166 mm per year
UBC - Zone 2A Horizontal
Seismic
Acceleration Factor: 0.15
Average Velocity: 6.25 mph
Wind Velocity
Design Velocity: 80 mph
Wind prevalent Direction Prevalent Direction: NE

3. PROCESS DESIGN PARAMETERS

3.1. DESIGN BASIS

3.1.1. DESIGN CAPACITIES

3.1.2. BATTERY LIMITS

Battery limits in the scope of work of this Project are the following:

Tie-in’s Line PID

Tie In-001A/B 24”-G-200-D2

Tie In-008 12”-G-212-D3

Tie In-002 To Relief Header

(1)
C= 150, criteria were taken from API RP 14E.
(2)
Pressure drop depends on hydraulic performance of the relief network.
All lines are sizing with additional 10% of flow as design margin.
INGENIERIA BASICA
BASES DE DISEÑO DE PROCESO

Tie In-003 4”-P-208-A2

Tie In-005 1 1/2”-IG-200-A2


Tie In-006
Tie In-007 1 1/2”-IG-201-D2
Tie In-004

3.1.3. APPLICABLE STANDARDS

The engineering development will be based on last editions of the following codes and
standards:

ASME
 ASME B31.3. Process Piping.
 ASME B31.8 Gas Transmission and Distribution Piping System.

API
 API SPEC 5L Specification for Line Pipe.
 API 6D Pipeline Valves.
 API RP 521 Guide for Pressure Relieving and Depressuring systems
 API RP 551 Process Measurement Instrumentation
 API RP 554 Process Instrumentation and Control
 API (MPMS) Manual of Petroleum Measurement Standards

ISA
 S5.1 Instrumentation Symbols and Identification.
 S5.2 Control Logic Diagram Symbols.
 S5.3 Graphic Symbols for Distributed Control/Shared Display
Instrumentation, Logic and Computer Systems.
 S5.4 Instrument Loop Diagram
 S18.1 Annunciator Sequences and Specifications.
 S84.01 Application of Safety Instrumented Systems for the Process
Industries.
 ANSI/ISA-S18.1 Annunciator Sequences and Specifications
 ANSI/ISA-S84.01Application of Safety Instrumented Systems for the Process
Industries.
 ANSI/ISA TR84.00.02 Safety Instrumented Systems (SIS) - Safety Integrity Level
(SIL) Evaluation Techniques, Part 1, Introduction
 S20 Specifications Forms for Process Measurement and Control
Instruments, Primary Elements and Control Valves
 ISA TR84.00.02 Safety Instrumented Functions (SIF) - Safety Integrity Level (SIL)
Evaluation Techniques, Part 1 to 5

(1)
C= 150, criteria were taken from API RP 14E.
(2)
Pressure drop depends on hydraulic performance of the relief network.
All lines are sizing with additional 10% of flow as design margin.
INGENIERIA BASICA
BASES DE DISEÑO DE PROCESO

 ANSI/ISA-S12.13.01 Performance Requirements for Combustible Gas Detectors


(IEC 61779-1 through 5 Mod)
 ANSI/ISA-S12.13.02 Recommended Practice for the Installation, Operation, and
Maintenance of Combustible Gas Detection Instruments
(IEC 61779-6 Mod)
NFPA
 NPFA 497 Sprinklers Classification of Flammable Liquids, Gases, or Vapors
and of Hazardous (Classified) locations for Electrical
Installations in Chemical Process Areas.

NACE
 NACE RP0169 Control of External Corrosion of Underground or Submerged
Metallic Piping Systems
 NACE RP0286 Electrical Isolation of Cathodically Protected Pipelines.

3.1.4. FEED GAS COMPOSITION

For process simulation, feed gas stream has been considered water saturated at
operating conditions (P y T). Following figure shows composition of feed gas stream to
dehydration plant.

3.1.5. PRODUCT SPECIFICATION

According to RUT (Reglamento Unico de Transporte) specifications, dehydrated gas


stream shall contain a maximum water of 6 lb/MMSCF and a maximum delivery
temperature of 120 ºF to meet the specifications in the delivery point.

3.2. DESIGN CRITERIA

3.2.1. TEMPERATURE

 Maximum design temperature = Maximum Operation Temperature + 50°F


 Minimum design temperature = Minimum Operation Temperature.

3.2.2. PRESSURE

 Internal Design Pressure for Process Vessel: Minimum design pressure 30 psig.
 Process vessel with pressure relief valve: 110 % maximum operating pressure or 25
psi over the maximum operating pressure, the high pressure will be chosen.
 Process vessel that works normally full (liquid and vapor): It is recommended to use
the following values:

(1)
C= 150, criteria were taken from API RP 14E.
(2)
Pressure drop depends on hydraulic performance of the relief network.
All lines are sizing with additional 10% of flow as design margin.
INGENIERIA BASICA
BASES DE DISEÑO DE PROCESO

3.2.3. PIPING SIZING AND EVALUATION CRITERIA

Flow velocity and pressure drop criteria used for line sizing, are listed below:
Pressure Drop
Type of fluid Velocity (1)
(psi / 100 ft)
Gas VG < V C 0.01 < P < 1.5
Liquid 3 ft/s < VL < 15 ft/s 0.2 < P < 3.0
Gas / Liquid 10 ft/s < VF < VC 0.2 < P < 3.0

Relief (Gas /
V <= 0.8 Mach N/A(2)
Liquid)

4. PROCESS DESCRIPTION

4.1. METERING SYSTEM

Glycol Dehydration Package consists of Gas Inlet Scrubber, Gas Inlet Filter Separator,
Scrubber and Glycol contactor (in tandem), Glycol/Gas exchanger and a Contactor
outlet scrubber. These equipments will have a bypass after the Gas Inlet Filter Separator
with the purpose of providing operative flexibility in case of needing to remove the Glycol
Contactor and Contactor outlet scrubber outside the line.

The metering unit will be constituted by two measurement branches simultaneously


working.

4.2. VALVULAS SECCIONADORAS

4.3. UTILITIES

5. SAFETY

A Hazard and operability analysis HAZOP will be leaded by and supported by


SOLUTEC,

(1)
C= 150, criteria were taken from API RP 14E.
(2)
Pressure drop depends on hydraulic performance of the relief network.
All lines are sizing with additional 10% of flow as design margin.
INGENIERIA BASICA
BASES DE DISEÑO DE PROCESO

The analysis will be oriented to the modifications to be implemented according to result


of the Front and end Engineering and Design. Areas not affected, will not be analyzed.
In addition to this a SIL Analysis will be developed after the HAZOP for Chevron
Facilities and operations personnel during the Detail Engineering in order to refine
issues related with safety and operability of the Dehydration Plant.

The Safety in Design Manual provided by CVX will be used to design the facilities
covered in the VEP-Dehydration.

(1)
C= 150, criteria were taken from API RP 14E.
(2)
Pressure drop depends on hydraulic performance of the relief network.
All lines are sizing with additional 10% of flow as design margin.