MICROMASTER 4,
SINAMICS G110/G120
USB / RS232 Adapter
Item-ID: 24072800
For suggestions about this document please use the following e-mail
address:
mailto:sdsupport.aud@siemens.com
Item-ID: 24072800
Table of Contents
Table of Contents ......................................................................................................... 3
1 Overview.......................................................................................................... 4
1.1 COM port number ............................................................................................. 5
1.1.1 Different behavior of STARTER and Drive Monitor when selecting the COM
port number.................................................................................................. 6
Behavior in STARTER ................................................................................. 6
Behavior in Drive Monitor............................................................................. 7
2 Appendix ......................................................................................................... 9
2.1 Internet links ..................................................................................................... 9
2.2 History............................................................................................................... 9
This entry is from the Internet offer of Siemens AG, Automation and Drives,
Copyright © Siemens AG 2007 All rights reserved
Service & Support. Clicking the link below directly displays the download
PDF_USB_RS232_Adapter_en_V1.2.doc
Item-ID: 24072800
1 Overview
(www.sitecom.com)
The adaptor from Roline showed the best results. With other adapters,
individual problems can occur at low baud rates. If data transfer rate
problems occur, then the min. baud rate should be set to 38400.
Please note that you must have installed the actual driver from the
particular manufacturer before using the adapter.
Item-ID: 24072800
Fig. 1-1
Item-ID: 24072800
1.1.1 Different behavior of STARTER and Drive Monitor when selecting the
COM port number
The different behavior of the STARTER and Drive Monitor tools - regarding
the selection of the COM port number - is discussed in the subsequent text.
Behavior in STARTER
New COM port numbers are automatically added to the selection list in the
"Set PG/PC interface…" under the tab "Interface" and can be selected
from there. Here, there are no restrictions regarding the COM port number.
Note:
It should be noted that in the "Set PG/PC interface…" for "PC COM-Port
Copyright © Siemens AG 2007 All rights reserved
PDF_USB_RS232_Adapter_en_V1.2.doc
Item-ID: 24072800
Fig. 1-2
Keep the default settings of all of the parameters and press the
"Advanced…" button.
The "Advanced Settings" window for the COM port is displayed.
Select the COM port number from the list that opens between 1 - 4 (refer to
Fig. 1-3).
Item-ID: 24072800
Fig. 1-3
It is possible that all COM port numbers between 1 and 4 are occupied.
In this case, select one that you are not using and exit the window with
"OK". > A message is displayed that this COM port is already being used
by another device; acknowledge this with "Yes"
Copyright © Siemens AG 2007 All rights reserved
Note:
PDF_USB_RS232_Adapter_en_V1.2.doc
Please note that in the "ONLINE Settings" for bus operation via RS485
the automatic mode must be selected under the "Interface" tab.
Otherwise, online operation with a USB adapter at RS232 is not possible.
Item-ID: 24072800
2 Appendix
Table 2-1
Topic Title
\1\ Web page Siemens A&D Customer Support
\2\ FAQ Recommendations for reliable RS485
communication between S7-200 and
MICROMASTER4
\3\ Update [internal] USS communications via RS485
Copyright © Siemens AG 2007 All rights reserved
\4\ Update [internal] Intl. Warning Sheet and RS485 Adapter for
PDF_USB_RS232_Adapter_en_V1.2.doc
MICROMASTER 4
2.2 History