Anda di halaman 1dari 24

TeSys D, K

Catalogue 2017
'S335' series contactors
for electrodomestic applications

schneider-electric.com
Presentation
TeSys contactors
TeSys D, TeSys K

TeSys D, TeSys K: S335 series


Best-in-class contactors
for electrodomestic applications

Schneider Electric
reliable control solutions for professionals

2
Presentation
TeSys contactors
TeSys D, TeSys K

Used in professional machines as electrical ovens, dishwashers,


fridges, washing achines, driers, heating machines,high pressure
cleaners, etc.
TeSys D and TeSys K S335 series contactors are designed for machine
power switching and controlling applications, while complying with
the electrodomestic EN60335 standards.

3
Presentation
TeSys contactors
TeSys D, TeSys K

TeSys D, TeSys K: S335 series contactors,

Schneider Electric introduces their best-in-class contactor ranges


for easing electro-domestic machine certification.
Made with dedicated plastic materials, TeSys D and TeSys K S335 series contactors
are fully compliant with EN 60335-1 standard.
They have been successfully submitted to:
p Glow Wire Test at 850 °C,
p Ball Pressure Test at 125 °C on all parts,
p IRC test validation at 250 V,
to resist to harshest electro-domestic environments.
Naturally, the standard ranges advantages are fully preserved:
p TeSys D longest electrical lifetime on the market,
p TeSys K high compactness.

4
Contents
TeSys contactors
TeSys D, TeSys K

TeSys contactors
Page
Presentation

TeSys D S335 series 6

TeSys K S335 series 7

References

TeSys D S335 series 8

TeSys K S335 series 10

Technical Data for Designers 11

TeSys D S335 series

Characteristics 12

Dimensions and schemes 15

TeSys K S335 series

Characteristics 16

Dimensions and schemes 20

5
Presentation - TeSys D
TeSys contactors
TeSys D S335 series - Contactors for Electrodomestic applications

NEW TeSys D - S335 series


PB108318.eps

Made of dedicated material,


fully EN 60335 compliant,
with unchanged commercial reference.
Applications:
p AC-3, up to 38 Amps
p AC-1, up to 40 Amps
p control circuits, up to 10 Amps.

Reliable and long-lasting,


TeSys D is the ultimate
choice for demanding or wide
power range applications
Range of 20 contactors for motors (AC-3),
resistive loads (AC-1), control circuits:
3P, 4P contactors:
p AC-3 ratings / 3 poles: 9, 12, 18, 25, 32, 38 A
p AC-1 ratings / 4 poles: 20, 25, 32, 40 A
p 1 NO + 1 NC embedded auxiliary contact on all ratings

Contactors for control circuits:


p 5 NO or 3 NO + 2 NC
p 10 A
Common features:
p connection by screw clamps terminal
p 24 or 230 V AC coils

See TeSys D S335 contactor selection tables


for available combinations of features.

6
Presentation - TeSys K
TeSys contactors
TeSys K S335 series - Contactors for Electrodomestic applications

NEW TeSys K - S335 series


LP4K PB111997.eps

New range of EN 60335 compliant


mini contactors:
- width: 45 mm
- height: 58 mm
- depth: 57 mm
- weight: 0.235 kg.
Applications:
p AC-3, up to 16 Amps
p AC-1, up to 20 Amps
p control circuits, up to 10 Amps.

Simple, robust, and compact,


TeSys K is optimized
for common applications
Range of 26 contactors for motors (AC-3),
resistive loads (AC-1), control circuits:
3P, 4P contactors:
p AC-3 ratings / 3 poles: 6, 9, 12, 16 A
p AC-1 rating / 4 poles: 20 A
p 1 NO or 1 NC embedded auxiliary contact

Contactors for control circuits:


p 4 NO or 2 NO + 2 NC or 3 NO + 1 NC
p 10 A

Common features:
p connection by screw clamps terminal
p 24 or 230 V AC coils

See TeSys K S335 contactor selection tables


for available combinations of features.

7
References - TeSys D
TeSys contactors
TeSys D S335 series - Contactors for Electrodomestic applications

3-pole contactors for Motor control


Standard power ratings Rated Instan- Commercial reference Weight
of 3-phase motors 50-60 Hz opera- taneous Replace dots by coil voltage code
in category AC-3 tional auxiliary (see chart below)
(q y 60 °C) current contacts
in AC-3 coil with surge
220 V 380 V 415 V 440 V 500 V 660 V 1000 V 440 V
230 V 415 V 690 V suppressor (1)
up to
PB108300.eps

kW kW kW kW kW kW kW A kg
2.2 4 4 4 5.5 5.5 – 9 1 1 LC1D09ppS335 0.320
3 5.5 5.5 5.5 7.5 7.5 – 12 1 1 LC1D12ppS335 0.325
4 7.5 9 9 10 10 – 18 1 1 LC1D18ppS335 0.330
5.5 11 11 11 15 15 – 25 1 1 LC1D25ppS335 0.370
7.5 15 15 15 18.5 18.5 – 32 1 1 LC1D32ppS335 0.375
9 18.5 18.5 18.5 18.5 18.5 – 38 1 1 LC1D38ppS335 0.380

LC1D09
4-pole contactors
Non inductive loads Number Instan- Commercial reference Weight
maximum current of poles taneous Replace dots by coil voltage code
(q y 60 °C) auxiliary (see chart below)
utilisation category AC-1 contacts
coil with surge
suppressor (1)

A kg
PB108318.eps

Contactors for Resistive load control


20 4 – 1 1 LC1DT20ppS335 0.365
25 4 – 1 1 LC1DT25ppS335 0.365
32 4 – 1 1 LC1DT32ppS335 0.425
40 4 – 1 1 LC1DT40ppS335 0.425
(1) A suppressor diode (Transil TM) in parallel with the coil prevents upstream sensitive components from damage by transient
high voltage during the coil switching.

Coil voltage codes


AC Volts 24 42 48 110 220 230 240 380 400
U 0.8…1.1 Uc at 50 Hz B7 - - - - P7 - - -
U 0.85…1.1 Uc at 60 Hz
LC1DT20

Characteristics: Dimensions, schemes:


pages 12 to 14 page 15
8
References - TeSys D
TeSys contactors
TeSys D S335 series - Contactors for Electrodomestic applications

Contactors for control circuit


Rated max Composition Commercial reference
operating current (Ie) Replace dots by coil voltage code
(see chart below)
PB114194.eps

coil with
surge suppressor

A
5-pole contactors for control circuits
10 3 2 CAD32ppS335
5 – CAD50ppS335

Coil voltage codes


CAD32 AC Volts 24 42 48 110 220 230 240 380 400
U 0.8…1.1 Uc at 50 Hz B7 - - - - P7 - - -
U 0.85…1.1 Uc at 60 Hz

Characteristics: Dimensions, schemes:


pages 12 to 14 page 15
9
References - TeSys K
TeSys contactors
TeSys K S335 series - Contactors for Electrodomestic applications

3-pole contactors for Motor control - connection by lugs


Standard power ratings Rated Instantaneous Commercial reference Weight
PB115725.eps

of 3-phase motors 50-60 Hz operational auxiliary Replace dots by coil voltage code
in category AC-3 current contacts (see chart below)
in AC-3
220 V 380 V 440/500 V 440 V
230 V 415 V 660/690 V up to

kW kW kW A kg
1.5 2.2 3 6 1 – LC1K0610ppS335 0.235
– 1 LC1K0601ppS335 0.235
LC1K12
2.2 4 4 9 1 – LC1K0910ppS335 0.235
– 1 LC1K0901ppS335 0.235
3 5.5 5.5 (y 440) 12 1 – LC1K1210ppS335 0.235
4 (u 480) – 1 LC1K1201ppS335 0.235
4 7.5 4 (y 440) 16 1 – LC1K1610ppS335 0.235
5.5 (440) – 1 LC1K1601ppS335 0.235
PB115726.eps

4-pole contactors - connection by lugs


Non inductive loads Number Instantaneous Commercial reference
Category AC-1 of poles auxiliary Replace dots by coil voltage code
Maximum current contacts (see chart below)
at (q y 50 °C)

LC1KT
A
20 4 – – – LC1KT20ppS335 0.235
2 2 – – LC1K098ppS335 0.235

4-pole contactors for Control circuit - connection by lugs


PB115727.eps

Control circuit Auxiliary Commercial reference


consumption contacts Replace dots by coil voltage code
(see chart below)

CAK Ith = 10 A 4 – CAK40ppS335 0.235


3 1 CAK31ppS335 0.235
2 2 CAK22ppS335 0.235

Coil voltage codes


AC Volts 24 42 48 110 220 230 240 380 400
U 0.8…1.15 Uc B7 - - - - P7 - - -

Characteristics: Dimensions, schemes:


pages 16 to 19 page 20
10
TeSys D, K

Technical
Data for
Designers
Contents
TeSys D S335 series:
Characteristics............................................................................ 12 to 14
Dimensions and schemes................................................................15

TeSys K S335 series:


Characteristics............................................................................ 16 to 19
Dimensions and schemes.............................................................. 20

11
Characteristics - TeSys D
TeSys contactors
TeSys D S335 series - Contactors for Electrodomestic applications

Environment
Contactor type LC1 D09…D18 D25…D38
DT20 and DT25 DT32 and DT40
Rated insulation voltage (Ui) Conforming to IEC 60947-4-1, V 690
overvoltage category III,
degree of pollution: 3
Rated impulse Conforming to IEC 60947 kV 6
withstand voltage (Uimp)
Conforming to standards IEC/EN 60947-4-1, IEC/EN 60947-5-1, EN 60335-1
Product certifications IEC, CCC, EAC, UA, TR
Degree of protection Conforming to IEC 60529
(front face) Power circuit connections Protection against direct finger contact IP20

Coil connection Protection against direct finger contact IP20

Protective treatment Conforming to IEC 60068-2-30 "TH"

Ambient air temperature Storage °C -60…+80


around the device
Operation °C -5°... +60°C (or -40°... +70°C at UC only)

Maximum operating altitude Without derating m 3000

Operating positions (1) Without derating AC


in the following positions
(other positions:
DF510743.eps

DF537812.eps
please contact us).

180 °
90

°
°

90
Flame resistance Conforming to UL 94 V0

Conforming to IEC 60695-2-1 °C 850

Shock resistance (2) Contactor open 10 gn 8 gn


1/2 sine wave = 11 ms
Contactor closed 15 gn 15 gn

Vibration resistance (2) Contactor open 2 gn


5…300 Hz
Contactor closed 4 gn 4 gn

(1) When mounting on a vertical rail, use a stop.


(2) Without modifying the contact states, in the most unfavourable direction (coil energised at Ue).

References: Dimensions, schemes:


pages 8 and 9 page 15
12
Characteristics - TeSys D
TeSys contactors
TeSys D S335 series - Contactors for Electrodomestic applications

Pole characteristics
Contactor type LC1D09 LC1DT20 LC1D12 LC1DT25 LC1D18 LC1DT32 LC1D25 LC1DT40 LC1D32 LC1D38
(3P) (4P) (3P) (4P) (3P) (4P) (3P) (4P) (3P) (3P)
Rated operational In AC-3, q y 60 °C A 9 12 18 25 32 38
current (Ie) In AC-1, q y 60 °C A 25 20 25 25 32 32 40 40 50 50
(Ue y 440 V)
Rated operational Up to V 690 690 690 690 690 690
voltage (Ue)
Frequency limits Of the operational Hz 25…400 25…400 25…400 25…400 25…400 25…400
current

Conventional q y 60 °C A 25 20 25 25 32 32 40 40 50 50
thermal current (Ith)
Rated making Conforming A 250 250 300 450 550 550
capacity (440 V) to IEC 60947
Rated breaking Conforming A 250 250 300 450 550 550
capacity (440 V) to IEC 60947
Permissible short For 1 s A 210 210 240 380 430 430
time rating For 10 s A 105 105 145 240 260 310
No current flowing
For 1 min A 61 61 84 120 138 150
for preceding 15
minutes with q y For 10 min A 30 30 40 50 60 60
40 °C
Fuse protection Without type 1 A 25 40 50 63 63 63
against short-circuits thermal type 2 A 20 25 35 40 63 63
(U y 690 V) overload
relay, gG fuse
Average impedance At Ith and 50 Hz mW 2.5 2.5 2.5 2 2 2
per pole
Power dissipation AC-3 W 0.20 0.36 0.8 1.25 2 3
per pole for the AC-1 W 1.56 1.56 2.5 3.2 5 5
above operational
currents

Control circuit characteristics, a.c. supply


Rated control circuit voltage 50/60 Hz V 12…690
(Uc)
Control voltage limits
50 or 60 Hz Operation –
coils Drop-out –
50/60 Hz Operation 0.8…1.1 Uc on 50 Hz and 0.85…1.1 Uc on 60 Hz at 60 °C
coils Drop-out 0.3…0.6 Uc at 60 °C
Average a 50 Hz Inrush 50 Hz coil VA –
consumption Cos j 0.75
at 20 °C
50/60 Hz VA 70
and at Uc
coil
Sealed 50 Hz coil VA –
Cos j 0.3
50/60 Hz VA 7
coil
a 60 Hz Inrush 60 Hz coil VA –
Cos j 0.75
50/60 Hz VA 70
coil
Sealed 60 Hz coil VA –
Cos j 0.3
50/60 Hz VA 7.5
coil
Heat 50/60 Hz W 2…3
dissipation
Operating time Closing "C" ms 12…22
Opening "O" ms 4…19
Mechanical durability 50 or 60 Hz coil –
in millions of operating 50/60 Hz coil on 15
cycles 50 Hz
Maximum operating rate In operating 3600
at ambient temperature cycles per hour
y 60 °C

References: Dimensions, schemes:


pages 8 and 9 page 15
13
Characteristics - TeSys D
TeSys contactors
TeSys D S335 series - Contactors for Electrodomestic applications

Power circuit connections


Screw clamp terminal connections
Contactor type LC1 D09 D18 D25 (3P) D32 D38 D18 and D25
and D12 DT20 (3P) (4P)
and DT25 DT32 and
DT40

Tightening Screw clamp terminals Connector


2 inputs
Flexible cable 1 conductor mm2 1…4 1.5…6 2.5…10 2.5…10
without cable end 2 conductors mm2 1…4 1.5…6 2.5…10 2.5…10
Flexible cable 1 conductor mm2 1…4 1…6 1…10 2.5…10
with cable end 2 conductors mm2 1…2.5 1…4 1.5…6 2.5…10
Solid cable 1 conductor mm2 1…4 1.5…6 1.5…10 2.5…16
without cable end 2 conductors mm2 1…4 1.5…6 2.5…10 2.5…16
Screwdriver Philips N° 2 N° 2 N° 2 N° 2
Flat screwdriver Ø Ø6 Ø6 Ø6 Ø6
Hexagonal key – – – –
Tightening torque N.m 1.7 1.7 2.5 1.8
Control circuit connections
Connection by cable (tightening via screw clamps)
Flexible cable 1 conductor mm2 1…4 1…4 1…4 1…4 1…4
without cable end 2 conductors mm2 1…4 1…4 1…4 1…4 1…4
Flexible cable 1 conductor mm2 1…4 1…4 1…4 1…4 1…4
with cable end 2 conductors mm2 1…2.5 1…2.5 1…2.5 1…2.5 1…2.5
Solid cable 1 conductor mm2 1…4 1…4 1…4 1…4 1…4
without cable end 2 conductors mm2 1…4 1…4 1…4 1…4 1…4
Screwdriver Philips N° 2 N° 2 N° 2 N° 2 N° 2
Flat screwdriver Ø Ø6 Ø6 Ø6 Ø6 Ø6
Tightening torque N.m 1.7 1.7 1.7 1.7 1.7
Characteristics of auxiliary contacts incorporated in the contactor
Mechanically linked Conforming to IEC 60947-5-1 Each TeSys D NO/NC embedded auxilliary contacts are certified ‘mechanicaly linked’.
contacts
Mirror contact Conforming to IEC 60947-4-1 All TeSys D NC auxilliary contacts are ‘miror’ certified and can be connected to a safety
module.
Rated operational voltage Up to V 690
(Ue)
Rated insulation voltage Conforming to IEC 60947-1 V 690
(Ui)
Conventional thermal For ambient temperature A 10
current (Ith) y 60 °C

References: Dimensions, schemes:


pages 8 and 9 page 15
14
Dimensions, schemes - TeSys D
TeSys contactors
TeSys D S335 series - Contactors for Electrodomestic applications

LC1D09…D18 (3-pole) LC1D25…D38 (3-pole)


db425761.eps

db425762.eps
77

85
86 45
92 45

LC1DT20, DT25 (4-pole) LC1DT32, DT40 (4-pole)

db425764.eps
db425763.eps

85

91
92 45 99 45

Contactors
3-pole contactors 4-pole contactors
LC1D09 to D38 LC1DT20 to DT40
3/L2

5/L3
1/L1

13/NO

21/NC

127267.eps
127266.eps

A1
A2

22
14
4/T2
2/T1

6/T3

References: Characteristics:
pages 8 and 9 page 12 to 14
15
Characteristics - TeSys K
TeSys contactors
TeSys K S335 series - Contactors for Electrodomestic applications

Environment characteristics
Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424

Product certifications LCp and LPp K06 to K12 UL, CSA

Operating positions Vertical axis Horizontal axis

DF511522.eps

DF511523.eps

DF564970.eps
90

90
90
°

˚
180°
°
90
Without derating Without derating Contactor pull-in voltage: 0.85 Uc

Connection Min. Max. Max. to IEC 60947


Screw clamp Solid conductor mm2 1 x 1.5 2x4 1 x 4 + 1 x 2.5
terminals Flexible conductor mm2 1 x 0.75 2x4 2 x 2.5
without cable end
Flexible conductor mm2 1 x 0.34 1 x 1.5 + 1 x 2.5 1 x 1.5 + 1 x 2.5
with cable end
Solder pins for With locating device between power and control circuits pins lenght 5 mm
printed circuit board Recommended minimum width and thickness layer for power printed circuit board
track : 4 mm x 35 microns
Tightening torque of screw-clamp terminals only N.m 0.8
Philips head n° 2 and Ø6
Terminal referencing Conforming to standards Up to 5 contacts, depending on model
EN 50005 and EN 50012
Rated insulation voltage Conforming to IEC 60947 V 690
(Ui) Conforming to VDE 0110 gr C V 750
Conforming to BS 5424, V 690
NF C 20-040
Conforming to CSA 22-2 n° 14, V 600
UL 508
Rated impulse withstand voltage (Uimp) kV 8

Protective treatment Conforming to IEC 60068 "TC" (Klimafest, Climateproof)


(DIN 50016)
Degree of protection Conforming to VDE 0106 Protection against direct finger contact

Ambient air temperature around Storage °C -50…+80


the device Operation °C -25…+50

Maximum operating altitude Without derating m 2000

Vibration resistance Contactor open 2 gn


5 ... 300 Hz Contactor closed 4 gn

Flame resistance Conforming to UL 94 Self-extinguishing materials V1


Conforming to NF F 16-101 Conforming to requirement 2
and 16-102
Shock resistance Contactor open On X axis: 6 gn
(1/2 sine wave, 11 ms) On Y and Z axes: 10 gn
Contactor closed On X axis: 10 gn
On Y and Z axes: 15 gn
Safe separation of circuits Conforming to VDE 0106 SELV (Safety Extra Low Voltage), up to 400 V
and IEC 60536

References: Dimensions, schemes:


page 10 page 20
16
Characteristics - TeSys K
TeSys contactors
TeSys K S335 series - Contactors for Electrodomestic applications

Pole characteristics
Type LCp  K06 K09 K12 K16
Conventional thermal For ambient temperature A 20
current (Ith) y 50 °C
Rated operational frequency Hz 50/60
Frequency limits of the operational current Hz Up to 400
Rated operational voltage (Ue) V 690
Rated making capacity I rms conforming to A 110 110 144 160
NF C 63 110 and IEC 60947
Rated breaking capacity I rms conforming 220/230 V A 110 110 – –
to NF C 63 110 380/400 V A 110 110 – –
and IEC 60947
415 V A 110 110 – –
440 V A 110 110 110 110
500 V A 80 80 80 80
660/690 V A 70 70 70 70

Permissible short In free air for a 1s A 90 90 115 115


time rating time “t” from cold 5 s A 85 85 105 105
state (q y 50 °C)
10 s A 80 80 100 100
30 s A 60 60 75 75
1 min A 45 45 55 55
3 min A 40 40 50 50
u 15 min A 20 20 25 25

Short-circuit protection gG fuse U y 440 V A 25


(aM fuse, see page 22009/2)
Average impedance per pole At Ith and 50 Hz mW 3
Use in category AC-1 Maximum rated operational A 20
resistive circuits, heating, current for a temperature y 50 °C
lighting (Ue y 440 V) Maximum rated operational A 16 for Ue only
current for a temperature y 70 °C
Rated operational current limits On-load factor 90 % 60 % 30 %
in relation to the on-load factor A 300 operating cycles/hour 13 15 18
and operating frequency
A 120 operating cycles/hour 15 18 19
A 30 operating cycles/hour 19 20 20

Increase in rated operational Apply the following coefficients to the above currents; these coefficients take into
current by paralleling of poles account an often unbalanced distribution of current between the poles
2 poles in parallel: K = 1.60
3 poles in parallel: K = 2.25
4 poles in parallel: K = 2.80

Use in category AC-3 Operational 115 V single-ph. kW 0.37 0.55 – –


squirrel cage motors power according 220 V single-ph. kW 0.75 1.1 – –
to the voltage.
220/230 V 3-ph. kW 1.5 2.2 3 4
Voltage 50 or
60 Hz 380/415 V 3-ph. kW 2.2 4 5.5 7.5
440/480 V 3-ph. kW 3 4 5.5/4 (480) 5.5/4 (480)
500/600 V 3-ph. kW 3 4 4 4
660/690 V 3-ph. kW 3 4 4 4

Maximum operating rate Op. cycles/h 600 900 1200


(in operating cycles/hour in Power 100 % 75 % 50 %
relation to % of rated power)

References: Dimensions, schemes:


page 10 page 20
17
Characteristics - TeSys K
TeSys contactors
TeSys K S335 series - Contactors for Electrodomestic applications

Control circuit characteristics


Rated control circuit voltage (Uc) V AC 24 or 230

Control voltage limits (y 50 °C) Operation 0.8…1.15 Uc (1)


single voltage coil
Drop-out u 0.20 Uc

Average consumption Inrush VA 30


at 20 °C and at Uc
Sealed VA 4.5

Heat dissipation W 1.3

Operating time at 20 °C and at Uc


Between coil energisation opening of the N/C contacts ms 5…15
and: closing of the N/O contacts ms 10…20
Between coil de-energisation opening of the N/O contacts ms 10…20
and: closing of the N/C contacts ms 15…25
Maximum immunity to microbreaks ms 2
Maximum operating rate In operating cycles per hour 3600
Mechanical durability at Uc 50/60 Hz coil 10
In millions of operating cycles
(1) LC1K12, LC1K16... : 0.85…1.15 Uc.

References: Dimensions, schemes:


page 10 page 20
18
Characteristics - TeSys K
TeSys contactors
TeSys K S335 series - Contactors for Electrodomestic applications

Auxiliary contacts characteristics of contactors


Number of auxiliary contacts On LCp K 1
Rated operational voltage (Ue) Up to V 690
Rated insulation voltage (Ui) Conforming to BS 5424 V 690
Conforming to IEC 60947 V 690
Conforming to VDE 0110 group C V 750
Conforming to CSA C 22-2 n° 14 V 600
Conventional For ambient temperature y 50 °C A 10
thermal current (Ith)
Frequency of the Hz Up to 400
operational current
Minimum switching U min (DIN 19 240) V 17
capacity I min mA 5
Short-circuit protection Conforming to IEC 60947 A 10
and VDE 0660, gG fuse
Rated making capacity Conforming to I rms A 110
IEC 60947
Short-time rating Permissible for 1s A 80
500 ms A 90
100 ms A 110
Insulation resistance MW > 10
Non-overlap distance mm 0.5

Power broken in VA Operational power of contacts conforming to IEC 60947


16 000 a.c. supply, category AC-15
DF564971.eps

10 000 Electrical durability (valid for up to 3600 operating cycles/hour) on an inductive


8000 load such as the coil of an electromagnet: making current (cos j 0.7) = 10 times
6000
5000
the power broken (cos j 0.4).
4000 1 Operating cycles 110/ 220/ 380/ 600/
3000 V 24 48 127 230 400 440 690
2000 1 million operating cycles VA 48 96 240 440 800 880 1200
3 million operating cycles VA 17 34 86 158 288 317 500
1000 4 10 million operating cycles VA 7 14 36 66 120 132 200
800
600
Occasional making capacity VA 1000 2050 5000 10000 14000 13000 9000
500
400 d.c. supply, category DC-13
300 Electrical durability (valid for up to 1200 operating cycles/hour) on an inductive
200 2a load such as the coil of an electromagnet, without economy resistor, the time
constant increasing with the load.
100
2b Operating cycles
80 2c V 24 48 110 220 440 600
60
40
1 million operating cycles W 120 80 60 52 51 50
24 48 110 220 380 500 3 million operating cycles W 55 38 30 28 26 25
120 440 690 V 10 million operating cycles W 15 11 9 8 7 6
Power broken in W Occasional making capacity W 720 600 400 300 230 200
DF564972.eps

1000 4
700
500
3
300
250 200

1. Breaking limit of contacts valid for:


200 100
80 2a b maximum of 50 operating cycles at 10 s intervals (power broken = making
60 current x cos j 0.7).
140 50
40 2b 2. Electrical durability of contacts for:
100 30 b 1 million operating cycles (2a)
20 b 3 million operating cycles (2b)
2c b 10 million operating cycles (2c).
50 10 3. Breaking limit of contacts valid for:
8 b maximum of 20 operating cycles at 10 s intervals with current passing for 0.5 s
6
20 per operating cycle.
12 24 48 110 220 440 600 V 4. Thermal limit.

References: Dimensions, schemes:


page 10 page 20
19
Dimensions, schemes - TeSys K
TeSys contactors
TeSys K S335 series - Contactors for Electrodomestic applications

Contactors
LC1K, LC1KT, CAK
On panel On mounting rail AM1 DP200 or AM1 DE200 (7 35 mm)
4xØ4
=
DB419872.eps

DF565023.eps
58

50

58
57 = 35 = 57 45
=

45

3-pole contactors
3 P + N/O 3 P + N/C
3/L2

3/L2
5/L3

7/L4

5/L3
1/L1

1/L1

21/NC
127355.eps

127356.eps
A1

A1
A2

A2

22
T3/6

T4/8

T3/6
T1/2

T2/4

T1/2

T2/4

4-pole contactors
4P 2 P N/O + 2 P N/C
R1

R3
3/L2

5/L3

7/L4
1/L1
127357.eps

127358.eps

3
A1
A1

A2
A2

4
R2

R4
2
T3/6

T4/8
T1/2

T2/4

CAK - 4 poles contactors for control circuits


4 N/O 3 N/O + 1 N/C 2 N/O + 2 N/C
13/NO

23/NO

33/NO

43/NO

13/NO

33/NO

43/NO

13/NO

43/NO
21/NC

21/NC

31/NC
DF533646.eps

DF533647.eps

DF533648.eps
A1

A1

A1
A2

A2

A2
14

24

34

44

14

22

34

44

14

22

32

44

References: Characteristics:
page 10 pages 16 to 19
20
Notes

21
Notes

22
Green Premium TM

Endorsing eco-friendly products in the industry

Schneider Electric’s Green Premium ecolabel is


committed to offering transparency, by disclosing
extensive and reliable information related to
the environmental impact of its products:

Green Premium is the only RoHS


label that allows you to Schneider Electric products are subject to RoHS requirements at
effectively develop and a worldwide level, even for the many products that are not required
promote an environmental
to comply with the terms of the regulation. Compliance certificates are
policy whilst preserving
your business efficiency.
available for products that fulfil the criteria of this European initiative,
This ecolabel guarantees which aims to eliminate hazardous substances.
compliance with up-to-date
environmental regulations, REACh
but it does more than this.
Schneider Electric applies the strict REACh regulation on its products
at a worldwide level, and discloses extensive information concerning
the presence of SVHC (Substances of Very High Concern) in all of
these products.

PEP: Product Environmental Profile


Over 75% of Schneider Electric publishes complete set of environmental data,
Schneider Electric including carbon footprint and energy consumption data
for each of the lifecycle phases on all of its products, in compliance
manufactured products with the ISO 14025 PEP ecopassport program. PEP is especially useful
have been awarded the for monitoring, controlling, saving energy, and/or reducing

Green Premium ecolabel carbon emissions.

EoLI: End of Life Instructions


Available at the click of a button, these instructions provide:
• Recyclability rates for Schneider Electric products.
• Guidance to mitigate personnel hazards during the dismantling of
Discover what we products and before recycling operations.
mean by green …. • Parts identification for recycling or for selective treatment, to mitigate
environmental hazards/ incompatibility with standard recycling processes.
Check your products!
Schneider Electric Industries SAS

35, rue Joseph Monier


CS 30323
92506 Rueil Malmaison Cedex
France

RCS Nanterre 954 503 439


Capital social 896 313 776 €
www.schneider-electric.com

April, 2017

 his document has been


T
printed on ecological paper.
© 2017 - Schneider Electric. All Rights Reserved.
This document has been
All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies.
printed on recycled paper
Document reference: LVCATESDK335_EN

Anda mungkin juga menyukai