Power Transformers Power transformers represent 60% react with the cellulose molecules in discharge that damages the of the asset value in a high voltage and break them down. This is transformer. substation, making them among the important as when the water content most expensive assets in electricity in the paper doubles, it can cut the transmission and distribution. remaining life of the transformer in Evaluating Moisture Knowing the condition of power half. Dynamics transformers is key to ensuring A scheduled oil sample and KF reliable grid operation, improving Poor oil quality and high moisture titration in a laboratory is the risk assessment, and implementing levels can lead to low dielectric common practice for estimating the more effective maintenance strength and eventual system failure. moisture level of transformer paper strategies. It has been reported that when based on the moisture-in-oil reading. relative moisture saturation goes The oil sample for analysis should be Moisture is one of the dominant above 20%, the relative saturation taken when the insulation system is factors that limit the lifetime of a (RS) dielectric strength of oil starts in equilibrium and thermally stable power transformer. For effective to decrease rapidly (Vaisala White – in other words, when winding and transformer lifetime management, Paper The Effect of Moisture on the oil temperatures have been relatively the moisture content of the insulation Breakdown Voltage of Transformer constant for a longer period of time. system, cellulose, and oil should be Oil B211282EN-A). kept at a low level. But is this really practical? In general, When the temperature rises, high most water is found in the solid After initial factory drying, the water content in the insulation, insulation paper and other cellulosic moisture content in solid insulation combined with dissolved gases in materials. The cellulose-oil insulation is typically between 0.5 and 1% the oil, may cause bubble formation system in a transformer is complex depending on requirements, and if the total pressure of gases and in regard to moisture distribution as starts to increase gradually over the water vapor exceeds the oil pressure the oil and cellulose exhibit reverse operating lifetime of the transformer. of the transformer. If bubbles form moisture absorption behavior – at The main moisture sources are or travel into energized parts of the increasing temperatures, moisture is residual moisture in thick structural transformer like the windings, there released from the paper surface and cellulose components, ingress from is a severe risk of system failure dissolved in the oil, and absorbed the atmosphere, and small amounts due to sudden local collapse of the back from the oil to the paper as of moisture generated as a by- dielectric-medium. temperatures decrease. There may be product of cellulose decomposition. considerable short-term variation in In a wet transformer, exceptional the oil moisture driven by changes in high-loading events can drive excess transformer loading and the ambient Issues Caused by Moisture moisture from the paper into the oil, temperature. The higher the water In a power transformer, the majority creating relative moisture saturation content in the paper insulation, the of water is found in the solid paper of 100% RS and the formation of bigger the variation in oil moisture insulation. Higher water content free water. The same may happen during temperature fluctuation. leads to accelerated deterioration if a heavily loaded wet transformer of the paper, reducing its degree of cools down quickly. Free water may The moisture absorption back polymerization (DP). Moisture and cause corrosion and rust particles in to paper is a significantly slower heat provide an optimal environment oil circulation pipes and radiators. process than desorption. This can for various compounds in the oil – In the worst case, free water can be seen as clear hysteresis in online such as acids and metal ions – to form around active parts, resulting moisture monitoring data measured 60 as a function of transformer temperature (Figure 1). With such 50 strong moisture dynamics, it may
Oil moisture (ppm)
be difficult or even impossible to 40
determine the correct moment to
take a representative oil sample for 30 Figure 1. Online moisture laboratory analysis. For example, monitoring data in ppm 20 if the oil sample is taken from the during temperature above-mentioned transformer at fluctuation in a 10 MVA 10 35°C, the laboratory result may give 10 15 20 25 30 35 40 45 50 55 (ONAN) transformer Temperature (°C) 30 ppm or 50 ppm depending on whether the transformer is in the cooling or loading phase at the point The moisture dynamics of a operational safety margin. Moreover, of sampling. Such a large variation transformer during normal operating by using moisture sensor readings may lead to significantly erroneous conditions can be significant. Online in ppm and published equilibrium conclusions about the condition of monitoring provides the operator moisture charts, it is possible the transformer. with valuable information on oil to estimate the water content in moisture, enabling further analysis the cellulose insulation during The lower the operating temperature such as evaluation of the risk of transformer operation. This would of a transformer, the less water is moisture saturation and decreased typically demand an intelligent found in the oil. This is an important dielectric strength, as well as input cooling system in order to maintain fact to take into account when data for paper moisture evaluation. the temperature as constant as assessing the moisture content Online monitoring allows the possible during the time period in solid insulation and evaluating operator to detect evolving moisture- needed to reach the moisture its effect on safe operation. A related risks and other early signs equilibrium state. transformer that operates normally of faults – and react appropriately. at a relatively low temperature For example, a transformer with high Alternatively, moisture and and with low oil moisture can have moisture levels may not be permitted temperature readings can be rapidly increasing moisture in oil to run at full load until dry-out has taken as an average from a longer levels during a single heavy overload occurred. This can be considered an period, which represents moisture event due to temperature-induced operational limit, and may differ from equilibrium better than a single point moisture migration from the paper the nominal limit, which in general oil sample during dynamic loading. surface. The return of moisture to assumes serviceable and dry oil. Recently published literature also the previous “normal” level may evaluates cellulose moisture directly take days or even weeks, meaning Online moisture monitoring can from the measured relative moisture that during a cooling period, relative provide valuable information on saturation and temperature of oil moisture saturation can become transformers that have previously (CIGRE TB349). dangerously high. been identified as having moisture problems. It is also valuable for Finally, it’s important to remember relatively lightly loaded transformers that monitoring alone will not fix Benefits of Online that may have moisture issues that anything – only taking action based Moisture Monitoring have not been detected by routine oil on monitoring information will result Online monitoring gives a true and sampling. in condition improvement in the real-time picture of the moisture long run. levels in transformer oil in all A moisture sensor provides operating conditions. the transformer with a proper
This material is subject to copyright protection, with all
www.vaisala.com/requestinfo copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly
www.vaisala.com Scan the code for
more information prohibited. All specifications — technical included — are subject to change without notice.