Anda di halaman 1dari 1

GOVERNMENT OF NEPAL

FOR 2M MINISTRY OF URBAN DEVELOPMENT


100 mm Thk.
PCC band
(1:2:4)
450 DEPARTMENT OF URBAN DEVELOPMENT
162 AND
Gravel Filling
BUILDING CONSTRUCTION
1500 150 mm
Geotextile Fabric NEW TOWN PROJECT COORDINATION OFFICE
150 mm BABARMAHAL, KATHMANDU
2000

750 50mmØ PVC weep pipe


spaced 1000mm apart NOTES:
50mmØ PVC weep pipe 1. All measurements are in MM unless otherwise noted.
spaced 1000mm apart 2. Architectural drawing should be read in conjunction with
Structural, Sanitary and Electrical drawings.
3. Site Engineer to notify the consultant if any discrepancy in
dimensions found in drawings as per the site condition.
4. All the Structural steel shall be of Grade Fy250.All the
150 1300 150 fabrication shall be carried out as per IS800:2007,Clause 17 .
5. All Structural steel should be shop welded unless strict
supervision provided by the experienced Engineer.
100mm thk. PCC (1:3:6)

100
100mm thk.Gravel Soling 1600
Compacted Earth
TYPICAL RETAINING WALL DETAIL
Scale=1:40
Note: Provide Joint @5m interval
FOR 3M 100 mm Thk.
PCC band
(1:2:4) 500
Gravel Filling
150 mm
1500 Geotextile Fabric
150 mm
ERMC (P) LTD.,
50mmØ PVC weep pipe NEST (P) LTD.,
spaced 1000mm apart 2018
GEOCOM INTERNATIONAL
(P) LTD. (JV)
New Baneshwor, Kathmandu
Project Title :
PREPARATION OF INTEGRATED URBAN
50mmØ PVC weep pipe DEVELOPMENT PLAN OF 14 MUNICIPALITIES
750 spaced 1000mm apart DED Title :
DETAIL ENGINEERING DESIGN OF INTEGRATED
AGRICULTURE MANAGEMENT INFRASTRUCTURE
DED Project Location :
Mulpani, Kageshwori Manohara Municipality
Sheet Title :
RETAINING WALL DETAILS
150 150
2000

110 100
Designed By : Drawn By :
ASHOK BHANDARI SANTOSH BASNET
100mm thk. PCC (1:3:6)
2300 17884 Civil 'A'
100mm thk.Gravel Soling
Checked By : Date :
Compacted Earth
- SEPT 2019
ST
TYPICAL RETAINING WALL DETAIL Scale -
Scale=1:40 1:50,1:30,1:20:1:10@ A3 S_RW_01
Note: Provide Joint @5m interval
REV_T1.0