Anda di halaman 1dari 11

Complete product range

MARINE FIREFIGHTING
& DISPERSANT SYSTEMS

Engineering

Design - Manufacturing - Marketing


www.jason.no
Design - Manufacturing - Marketing

TABLE OF CONTENT ENSURE SAFETY THROUGH EXPERIENCE


Jason engineering is at the forefront of developing and
offering intelligent compact design and integrated solutions
to the marine firefighting industry. The company was
Jason introduction: Ensure safety through experience 3
established in 1898 and is well known for its highly skilled and
A brief selection: Marine Firefighting 5
experienced engineering team.
Complete FiFi range 6

Telescopic mast 7 The company has a significant worldwide installed base. The Jason vision is based on
intelligent design, high quality and low maintenance requirements at competitive prices.
Pumps 8 Jason Engineering is a flexible partner. The organisation has an efficient structure that
enables the construction and delivery of standard equipment and tailored solutions to meet
Monitors 9 our customer’s needs and specifications.

External firefighting gearboxes & drivers 11 MARINE FIREFIGHTING


Since 1974, Jason has offered a wide range of firefighting solutions for FiFi I, II and III. In
Remote control system 12 addition, the Jason portfolio features telescopic monitor masts and tailor-made engineering
solutions for our customers. The Jason vision is based on intelligent design, high quality and
Water spray & foam mixing system 13 low maintenance requirements at competitive prices.

Classification requirements 14
DISPERSANT SYSTEMS
Designed for spraying optimal quantities of dispersant liquids onto surface based oil slicks.
Dispersant systems 16 Intended for all vessels catering to the offshore services for optimal oil spill prevention. The
Jason product suite is available as external, built-in or mobile solutions
- according to NOFO standard.

DESIGN MANUFACTURING
Jason’s customer-oriented approach to firefighting solutions and its With the acquisition of the Aker Kvaerner Subsea FiFi Department
vertically integrated component supply has earned it the reputation in 2007, Jason incorporated the ability to design and manufacture
of being an adaptive, flexible partner in marine construction and all key elements of ship sets in-house: fire monitors, fire pumps,
outfitting. By maintaining open channels of positive communication and transmissions as well as electric/hydraulic control, all of which
with its customers, Jason has been able to implement timely and comply with class notations.
pertinent product improvements, new features and other changes to
keep its solutions at the forefront of marine firefighting technology.
PRODUCT RANGE
Since 1974, Jason has offered a wide range of firefighting solutions
SALES, SUPPORT & TRAINING for FiFi I, II and III. In addition, the Jason portfolio features telescopic
Jason has a global network of qualified partners to ensure local sup-
masts, dispersant solutions and tailor-made engineering solutions for
port and training. The Jason spare part department ensure efficient
our customers.
supply of needed components worldwide.

3
Design - Manufacturing - Marketing

A BRIEF SELECTION: MARINE FIREFIGHTING

World leading supplier of external marine firefighting equipment

JASON firefighting systems has since it’s origin


in 1974 delivered over 1200 FiFi systems to
the marine and offshore industry. It makes us
the world-wide leader in design and supply of
external fire fighting systems at sea. Our office and
production is located in Drammen, Norway.

Abeille Bourbon
the French coastguard vessel built in 2005
with Jason Eureka FiFi II BV classed system.
Three fire monitors each with 2400m³/h
capacity and a water throw of 150 meters.

Stril Posedion
built in 1995 is equipped with Jason
Eureka FiFi II + DNV class system. Two fire
monitors each with 3600 m³/h capacity
and the world-wide longest verified water
throw of 236 meters.

North American Fabricators


built in 2007 is equipped with Jason Eureka
FiFi I ABS classed system. Two fire monitors
each with 1200 m³h capacity and a water
throw of 120 meters.

4 5
Design - Manufacturing - Marketing

COMPLETE FIFI RANGE TELESCOPIC MAST

FIREFIGHTING I SYSTEM
One or two fire pumps installed in the engine room driven
by the main engines with a step-up transmission gear, or
using electric motors. The pump(s) provides water for two
fire monitors and an external water spray system installed for
self protection.

Optional foam system can be included

System capacity: 2700-3400 m³/h


Total monitor capacity: 2400 m³/h
Water throw length: 120 m

FIREFIGHTING II AND III SYSTEM


Minimum two fire pumps driven by the main engines with a
step-up gear or using electric motors. Depending on class
society two, three or four monitors are required for long
range fire fighting. Optional external water spray system can
be installed to obtain FiFi II + I class notification.

System capacity: 7200-9600 m³/h


Total monitor capacity: 9600 m³/h
Water throw length: 150 m-180 m

Due to the Jason Monitors favourable single flow design, a


throw length far in excess of the requirement is achieved.

To extend and complete the application of firefighting


equipment Jason have developed a telescopic mast
series making it possible to have fire monitors installed
at the top. The Jason Telescopic mast is manufactured in
two standard sizes for water and foam monitors as well
NON CLASSED FIREFIGHTING SYSTEMS as additional powder nozzle. The masts are tailormade
and available in variouse lengths with corresponding
External FiFi systems with capacity less than FiFi I have no
telescopic strokes.
formal classification. Fire pumps are driven by dedicated
diesel engines, PTO gearboxes or electric motor. A minimum
The JASON telescopic mast series is a hydraulic operated
of 300 m³/h unit capacity is recommended to achieve
mast for water and foam monitors.
efficient firefighting.
It is designed for marine and industrial applications
System capacity: 600-2400 m³/h
such as Fire Boats, Tugs, Oil Jetties and Petrochemical
Industry.

Elevated by hydraulic operated combined jacking and


locking mechanism. Remote controlled from a single
control switch. The plunger may be stopped and locked in
any position between zero and max. stroke.

Capacity monitor: 500-1200 m³/h


FIREBOAT DEDICATED SYSTEMS Elevation stroke: 5-16 meter
Fireboat systems are tailor made firefighting systems Elevation speed: 2,5 m/min max
developed in cooperation with fire departments and
naval architects.

System capacity: 600-4500 m³/h


Total monitor capacity: up to 3900 m³/h
Water throw length: up to 240 m

Telescopic mast with jet/fog monitor

6 7
Design - Manufacturing - Marketing

PUMPS MONITORS Jason has a wide range of monitors which cover all class notations FiFi 1/2, FiFi I, FiFi II & FiFi III.
All monitors are designed for a long service life with low maintenance requirements.

OGF 250X350
The standard pump for FiFi I systems and the most used firewater pump world-
wide for FiFi systems. It is a compact and ultra light single suction radial split
centrifugal pump. Horizontal mounting with end suction or side/bottom suction MM302HJF
bends.
JASON fire fighting monitor series MM300 is a single flow path water/foam monitor
Capacity: 700-1700 m³/h at 1500-2000 rpm. designed for marine and offshore applications. It is a low profile monitor, specially designed
Total head: 110-150 mlc for helideck protection. The monitor is fitted with jet/fog type nozzle suitable for water and
Materials: Casing in Ni-Al-Bronze or Nodular AFFF type of foam. The monitor is designed with two swivels, one for horizontal, and one
Cast Iron for the vertical movement. These are with self-locking worm and wheel type gear, totally
Impeller in Ni-Al- Bronze sealed and greased for life. The monitor operates hydraulically and with electric remote
Shaft in stainless steel control. Materials are in bronze and high grade steel
Weight: 450 kg
Max capacity: 220 m3/h
Weigth: 90 kg
Length of jet: 65 meters (approx.)

OGF 300X400
A larger version of the OGF 250. Single stage, single suction centrifugal pump.
Horizontal OGF 250 mounting with end suction or side/bottom suction bends. MM402HD/HJF-F
Capacity: 1200-2800 m³/h at 1200-1800 rpm. Long and short barrel single flow path monitor with electric/hydraulic remote control.
Total head: 110-160 mlc Fitted with straight jet nozzle (with jet deflector) or jet/fog nozzle for water and foam.
Materials: Casing in Ni-Al-Bronze
or Nodular Cast Iron Max capacity: 450 m³/h
Impeller in Ni-Al- Bronze Weight: 125 kg
Shaft in stainless steel Length of jet: 90 meters (approx)
Weight: 900 kg

MM602HD
Single flow path long barrel water monitor with electric/hydraulic
remote control. Fitted with straight jet nozzle with jet deflector.

OGF 300X450 Max capacity: 1200 m³/h


Weight: 200 kg
Single stage, double suction centrifugal pump. Horizontal mounting with Length of jet: 130 meters (approx)
sideside, bottom-top, side-top, and bottom-side suction/discharge execution.
Capacity: 1500-3400 m³/h at 1000-1800 rpm.
Total head: 110-170 mlc
Materials: Casing in Ni-Al-Bronze
or Nodular Cast Iron
Impeller in Ni-Al- Bronze
Shaft in stainless steel MM602HJF (Fixed or variable jet/fog nozzle)
Weight: 1500 kg
Single flow path monitor with electric/hydraulic remote control. Fitted with variable
or fixed capacity jet/fog type nozzle. Nozzle control accomplished from the monitor’s
control panel which enables adjustment of the jet type from straight stream to fog
shape. The variable flow nozzle is unique in its ability to enable the capacity of the
monitor to be changed while the monitor is in operation

FiFi II Max capacity: 1200/300 m3/h


Weight: 150 kg
Standard pump for FiFi II systems. It is a double suction, one stage Length of jet: 130 meters (approx.)
axially split centrifugal pump. Horizontal mounting with side-side,
bottom-top, side-top, and bottom-side suction/discharge execution.

Capacity: 2000-4000 m³/h at 1000-1800 rpm


Total head: 110-190 mlc
Materials: Casing in Ni-Al-Bronze
FM200HD
or Nodular Cast Iron Single flow path water monitor with electric/hydraulic remote
Impeller in Ni-Al- Bronze control. Fitted with straight jet nozzle with jet deflector.
Shaft in stainless steel
Weight: 1600 kg Max capacity: 1500 m³/h
Weight: 320 kg
Length of jet: 140 meters (approx)

8 9
Design - Manufacturing - Marketing

MONITORS EXTERNAL FIREFIGHTING GEARBOXES & DRIVERS


Jason offers a wide range of purpose-built transmission which are suitable for
most applications. The gearboxes may be equipped with multiple output shafts
for various tasks. Independent engagement is standard.

All gearboxes are tested and approved by the classification societies.


FM200HJF (Fixed or variable jet/fog nozzle) A typical gearbox within the special range is outlined below.

Single flow path monitor with electric/hydraulic remote control. Fitted with variable or fixed
capacity jet/fog type nozzle. Nozzle control accomplished from the monitor’s control panel
which enables adjustment of the jet type from straight stream to fog shape.

The variable flow nozzle is unique in its ability to enable the capacity of the monitor to
be changed while the monitor is in operation. See our web page www.jason.no for more
FIFI INTERGRATED GEARBOX & CLUTCH
information. High quality step-up transmission with built in operated hydraulic clutch for fire pump drive.
Special integrated design with fire pump flanged on to the gear/clutch gives the most compact
Max capacity: 1500/300 m3/h building length. Vertical offset shaft with minium alignment work.
Weight: 320 kg
Length of jet: 140 meters (approx.) Engine speed: 600-1800 rpm
Pump speed: max 2000 rpm
Pump power consumption: max 1300 kW
Standard torque capacity: 7500-16000 Nm
Max pump capacity: 2100 m³/h

FM250HD FIFI STAND ALONE GEARBOXES & CLUTCHES *TAILORMADE


High quality step-up transmission gearbox with built in clutch for lager fire pump drive.
Single flow path water monitor with electric/hydraulic remote control. Fitted with long water
Stand alone tailormade design with vertical or horizontal offset shaft. Coupled to the fire
barrel and straight jet water nozzle with jet deflector
pump by bowtooth coupling.
Max capacity: 2800 m3/h Engine speed: 600-1800 rpm
Weight: 485 kg Pump speed: max 1800 rpm
Length of jet: 150 meter (approx.) Pump power consumption: max 2600 kW
Standard torque capacity: 20000-40000 Nm

FM250HJF (Fixed or variable jet/fog nozzle)


Single flow path monitor with electric/hydraulic remote control. Fitted with variable or fixed DIESEL ENGINE DRIVER
capacity jet/fog type nozzle. Nozzle control accomplished from the monitor’s control panel High speed, turbo charged marine type diesel engine rated for 12-24
which enables adjustment of the jet type from straight stream to fog shape hours continuous operation plus 10% overload capacity. Marine type
instrumentation, classification agency approved. Pre-aligned and
The variable flow nozzle is unique in its ability to enable the capacity of the monitor to be complete skid mounted with fire pump and auxiliaries.
changed while the monitor is in operation
Engine speed: 1500-2100 rpm
Max capacity: 2800 m3/h Rating: 100-2400 kW
Weight: 485 kg
Length of jet: 150 meters (approx.)

ELECTRIC MOTOR DRIVER


IP 23 to IP 55 electric motors marine type. Classification agency approved.
FM400HD Pre-aligned and complete skid mounted with fire pump and auxiliaries.
Single flow path long barrel water monitorwith electric/hydraulic remote control with low
speed/high torque hydraulic motors. Straight jet type water nozzle with jet deflector. Rating: 100-2400 kW
Motor speed: 1500-1800 rpm
Max capacity: 3900 m³/h Voltage: meet all requirements
Weight: 1550 kg
Length of jet: 220 meters (approx) Horizontal & vertical execution

10 11
Design - Manufacturing - Marketing

REMOTE CONTROL SYSTEM WATER SPRAY SYSTEM


Material: Bronze or equal seawater resistant
The remote control systems for pumps and
Capacity: 300 - 800 m3/h
monitors are designed and manufactured by
Quantity: 30 - 70 nozzles
Jason Engineering.
Delivered with 1/2” and 2 NPT male
thread and variouse orifice openings
All sizes are supplied, from small monitor
controls, to large PLC based systems with
Nozzle types: Open standard upright sprinkler
sequence controlled start up and remote control
Open sidewall sprinkler
of all valves and monitors.
Open window sprinkler

Design and calculation of the water curtain fire fighting systems by Jason Engineering. Documentation to
classification society for approval.

Design of advanced naval type water curtain systems, for ABC protection. (Atomic, Biological, Chemical
protection).

10 liters pr. minute pr. m2 on exposed vertical surface of hull including superstructure, deckhouses, lifeboats and
monitors. System calculation by computer program. No manual adjustment after installation. Various nozzle types
are used depending on surface structure. Each nozzle is individually calculated and marked for specific position.

Design and calculation of water spray system is done by Jason Engineering.

FOAM MIXING SYSTEM


PORTABLE JOYSTICK & RADIO CONTROL
Portable box or fixed panel with 1-4 joysticks for
monitor operation. Stop buttons, jet/fog, water/
foam and adjustable switches. To be able to control and extinguish fires, particularly a fire in
hydrocarbon and chemical plants, foam extinguishing equipment
Radio control as option. with large capacity and long reach is required. Some of the
classification societies have called for and included foam
spraying capability for ships having the FiFi III notation. The
minimum capacity is 2 x 5000 l/min. Fixed foam monitors and
foam concentrate liquid for no less than 30 min operation of both
monitors simultaneously.

Foam system for mixing and proportioning of water/foam to the


firefighting monitors. Mixture 0-6% with wither Around-The-Pump
ejector or foam pumps. Necessary system valves are supplied.
Foam liquid is supplied from a storage tank through the ejector or
pump. The chemicals may include protein foam, synthetic foam,
CLUTCH/VALVE PANEL AFFF, fluor-protein-foam or similar.
Flush type mimic control panel. Installation in ECR
and bridge.
PLC based interlocks, remote control, monitoring
of clutches and actuator controlled valves.

12 13
Design - Manufacturing - Marketing

CLASSIFICATION REQUIREMENTS
Classification societies have issued rules and regulations
for vessels equipped with large fire fighting systems.

The Jason fire fighting equipment has been tested and


approved by the classification societies. Vessels fitted with
In the Mexico Gulf incident FiFi I was in use.
Jason equipment are granted the additional class notation
“Fire Fighter I”, “Fire Fighter II” or “Fire Fighter III”.

FiFi I FiFi III


Minimum capacity of 2.400 m3/h divided on two monitors Minimum capacity of 9.600 m3/h divided on 4 monitors.
with minimum throw length of 120 meters in still air. The Minimum throw length is 150 meters in still air. The throw
minimum throw height is 45 meters measured from sea height has to be minimum of 80 meters from sea level
level and 70 meters away from the nearest part of the measured 70 meters and away from the nearest part of the
vessel. In addition the vessel has to be equipped with a vessel. In addition the vessel shall be fitted with two foam
spray system for self-protection. monitors, each with capacity of 300m3/h and throw height Classification Monitors Pumps Pump Height of Length of Water j
of 50 meters above sea level. authority capacity throw (m) throw (m) deflecto
FiFi II m3/h
Minimum capacity of 7.200 m3/h divided on two or three For FiFi II & FiFi III an arrangement with less number of DNV
monitors. Minimum throw length is 150 meters in still air. monitors may be considered. In such cases the length of FiFi I 2 1-2 2400 45 120 2
The throw height has to be minimum of 80 meters from sea throw and height are increased to 180 meters and 110 FiFi II 3-4 2-4 7200 70 150 2
level measured 70 meters and away from the nearest part meters respectively.
FiFi II 2 2 7200 110 180 2
of the vessel.
FiFi III 4 2-4 9600 70 180 2
Lloyds
FiFi
Classification I Monitors 2
Pumps Pump Height of 2400
Length of Water45jet JASON has120an
authority FiFi II 3-4 capacity throw (m)
throw (m) 7200 deflectors
70 offering where
150
m3/h tagged
DNV FiFi III 4 10000 70 150
ABS FiFi I 2 1-2 2400 45 120 2 
FiFi II 3-4 2-4 7200 70 150 2 
World’s longest throw length FiFi FiFi
II I 2 22 7200 1-2 110 2400
180 2 45  120 2
Approx 720 feet, 236 meters
FiFi FiFi
III II 4 2-4
3-4 9600 2-4 70 180
7200 2 70  150 2
Lloyds
FiFi III 4 2-4 9600 70  150 2
Witness verification by DNV Bureau
FiFi I
FiFiVeritas
II
2
3-4
2400
7200
45
70
120
150 
Jason FM400 monitors with capacity 3600 m³/h each FiFi III
FiFi I
4
2
10000
1-2
70
2400
150
45

120 2
ABS
FiFi FiFi
I II 2 3-4
1-2 2400 2-4 45 7200
120 2 70  150 2
FiFi II 3-4 2-4 7200 70 150 2 
FiFi FiFi
III III 4 4
2-4 9600 2-4 70 9600
150 2 70  150 2
Germanische Ll.
Bureau Veritas 
FiFi I 2 1-2 2400 45 120 2 
FiFi FiFi
II I 3-4 2-4 7200 70 150 2 
FiFi FiFi
III II 4 2-4 9600 70 150 2 
Germanische Ll. 
FiFiFiFi
I III 
FiFi II 
Height FiFiof
IIIthrow should be measured vertically from sea level to mean impact area ata horizontal distance a
part of the vessel
Height of throw should be measured vertically from sea level to mean impact area at a horizontal distance at least 70 m from the nearest
Length
part of throw should be measured horizontally from the mean impact area to the nearest part of the vess
of the vessel
Length of throw should be measured horizontally from the mean impact area to the nearest part of the vessel when all monitors ate in
satisfactory operation simultaneously. (DNV)
satisfactory operation simultaneously. (DNV)
Lloyds,
Lloyds, ABS,ABS,
BV & GLBV measure
& GLrequirement
measure requirement
of length is horizontallyof length
from is horizontally
the monitor from
outlet to the mean the
impact monitor outlet to the mean im
area

14 15
Design - Manufacturing - Marketing

System design and verification


in close cooperation with SINTEF
Materials and Chemistry in
Trondheim - NORWAY developed
according to the NOFO standard.

Developed by

Containerized hydraulic dispersant system


A new dispersant boat application prototype
for use under Arctic and ice-infested areas
has been designed and constructed through
a co-operation project between Jason
Engineering and SINTEF. This system allows
a flexible application between ice floes, is
DISPERSANT SYSTEMS easily transportable, protected from icing
(containerized), and can be operated from a wide
range of vessels.
Jason Engineering AS is today the leading company in design and
manufacturer of dispersant spraying systems. Spraying booms and A great advantage of this system compared
valves are remote controlled from the bridge. Speed range up to 18 to conventional vessel-mounted spray arms is
knots, wind velocity up to 20m/sec and total spray width up to 30 the ability to manoeuvre the spray arm close to
meters. These systems are designed for spraying neat dispersant the slick and conduct more precise application
onto oil slick on the sea surface. It is intended for installation and use avoiding wind induced drift of dispersant and
on board offshore supply/stand-by vessels or large ocean going tugs. reducing loss of dispersant due to the spraying
DISPERSANT SYSTEMS over the ice floes.
Dispersing oil spills by applying
a spray of chemicals on the spill Dispersant spraying using the new
surface. Easy to store and handle manoeuvrable hydraulic -based spray arm
Booms, nozzles, manifold, couplings are made from high booms. Horizontal or vertical hinged,
sectioned on request. Spray nozzles system indicating an effectiveness of more than
grade stainless steel or other seawater resistant materials for neat dispersant. 90%.
Wired or wireless remote controlled
Light weight design for easy and manual mobilization
Length: up to 11.0 meter.
Quick couplings for all hose connections. Remote controlled Boom diameter: ND 25-50.
spray nozzle flow/pressure

16 17
Design - Manufacturing - Marketing

DSP-TW-1P/2P-H
Height between the sea surface and the manifold Electric power required is 3-4 kw. The pump motor
should be approx. 3m and can easily be adjusted speed is controlled with frequency converter. Pump
up and down by means of two ropes, jagging speed/pressure is remote operated by means of a
wheels and two small hydraulic motor driven small bridge mounted control panel with two push
winches (explosion proof system). buttons and a digital display.

Soft hoses with quick couplings act as dispersant The complete dispersant spray system is remote
supply line from the boom down to the nozzle controlled by means of a control cabinet, shut-
manifold. At the manifold inlet a specially designed off valves with hydraulic actuator and two small
pressure pilot operated check valve is fitted. This hydraulic motor driven winches on each boom in
valve has also an integrated hose swivel coupling order to adjust distance between sea surface and
in order to prevent the supply hoses from twisting. the nozzle manifold.

The dispersant spray nozzles are flat jet type with A small hydraulic power unit with all necessary
spray angle of approx. 45 degrees. The flowrate is control valves is included and should be installed
2.5-5 ltr/min per nozzle in one of the twin manifolds below deck in a safe protected area.
and 10 ltr/min in the other one (at 2 bar inlet
DSP-TW-2P-H pressure). The valve actuators have sensors for indication of
Hydraulic twin boom system with two dispersant pumps open/closed position.
The boom is fitted with “hook-on” type hinges for A portable control panel with flexible cable and
quick and easy erection. plug in connector is included. It has switches for
operation of the two winches and valves plus
Weight of the boom exclude the two small hydraulic indicating light for valve position.
motor driven winches is approx.
60 kg. As an option the system can be supplied with
wireless remote control.

DSP-85-3-60 Dispersant pumps are electric motor driven


multistage centrifugal non-selfpriming type with all
Total capacity is approx. 60 l/min trough two booms As standard a wall mounting type starter cabinet is “wet parts” in stainless steel.
each fitted with down-tube hoses and three flat jet included. The cabinet is equipped with terminals make
type spray nozzles. it possible to fit remote start/stop.
Optionally the pump may be supplied with frequency
converter making the system more flexible with
The dispersant tank is normally a ship structure tank
internally coated with an epoxy paint system with regards to step less nozzle pressure and flow rate.
DSP-TW-2P-H-XB
proper protection against corrosion. It is intended for installation and use onboard With bow mounted spray booms the vessel can
Pump materials is stainless steel. Jason supplied tube offshore supply/stand-by vessels with X-BOW apply dispersant on oil spill at a speed range up to
Dispersant pump is a small vertical mounted fitted items are made from bronze, brass or stainless design or other vessels with covered foredeck. 15 knots and total spray width of approx. 28m.
multistage centrifugal pump, electric motor driven steel.
with a power consumption of approx. 1 kW. Support arms for the nozzle manifold are mounted The support arm (stb. & port) will be sliding out
indoor and as near the bow as possible in order to through a hatch in the ship side.
apply dispersant on undisturbed oil in front of the
bow wave. Nozzle manifold with supply hoses, ropes etc.
are ready mounted safely “indoor”. The complete
DSP-S-100-9-90 This make the dispersant operation far more assembly by means of a hydraulic operated
efficient than with the booms located midship of the mechanism is then brought out and in position for
Single spray boom system with a boom length of ten Weight: 90 kg (approx.) the dispersing operation.
Length: 10 meters vessel.
meter and nine spray nozzels which are screw fitted
into sockets in the boom. As standard the boom is Number of nozzles: 9
supplied with nozzels for diluted dispersant only. The Boom diameter: ND 50 Booms, nozzles, manifold, couplings are made from high grade stainless steel
system is equipped with an ejector type proportioner Minimum weight for easy and manual mobilization
which mixes seawater and dispersant fluid with
De-icing equipment included
water supply from a general service pump. Dosage
of neat dispersant into the seawater is adjusted Wireless remote controlled
through the proportioner throttle valve. The pump
pressure may also be adjusted with a relief valve.
The system is in accordance with NOFO standard and recommendations.
System design and verification in close cooperation with SINTEF Materials and Chemistry in Trondheim - NORWAY.

18 19
®

Engineering

Jason Engineering AS
Grønland 76-82
PO Box 2151 Strømsø
3003 Drammen
Norway

Phone: +47 32 20 45 50
Fax: +47 32 20 45 60

jason@jason.no
www.jason.no

Jason main office and partner coverage globally