MARINE FIREFIGHTING
& DISPERSANT SYSTEMS
Engineering
Telescopic mast 7 The company has a significant worldwide installed base. The Jason vision is based on
intelligent design, high quality and low maintenance requirements at competitive prices.
Pumps 8 Jason Engineering is a flexible partner. The organisation has an efficient structure that
enables the construction and delivery of standard equipment and tailored solutions to meet
Monitors 9 our customer’s needs and specifications.
Classification requirements 14
DISPERSANT SYSTEMS
Designed for spraying optimal quantities of dispersant liquids onto surface based oil slicks.
Dispersant systems 16 Intended for all vessels catering to the offshore services for optimal oil spill prevention. The
Jason product suite is available as external, built-in or mobile solutions
- according to NOFO standard.
DESIGN MANUFACTURING
Jason’s customer-oriented approach to firefighting solutions and its With the acquisition of the Aker Kvaerner Subsea FiFi Department
vertically integrated component supply has earned it the reputation in 2007, Jason incorporated the ability to design and manufacture
of being an adaptive, flexible partner in marine construction and all key elements of ship sets in-house: fire monitors, fire pumps,
outfitting. By maintaining open channels of positive communication and transmissions as well as electric/hydraulic control, all of which
with its customers, Jason has been able to implement timely and comply with class notations.
pertinent product improvements, new features and other changes to
keep its solutions at the forefront of marine firefighting technology.
PRODUCT RANGE
Since 1974, Jason has offered a wide range of firefighting solutions
SALES, SUPPORT & TRAINING for FiFi I, II and III. In addition, the Jason portfolio features telescopic
Jason has a global network of qualified partners to ensure local sup-
masts, dispersant solutions and tailor-made engineering solutions for
port and training. The Jason spare part department ensure efficient
our customers.
supply of needed components worldwide.
3
Design - Manufacturing - Marketing
Abeille Bourbon
the French coastguard vessel built in 2005
with Jason Eureka FiFi II BV classed system.
Three fire monitors each with 2400m³/h
capacity and a water throw of 150 meters.
Stril Posedion
built in 1995 is equipped with Jason
Eureka FiFi II + DNV class system. Two fire
monitors each with 3600 m³/h capacity
and the world-wide longest verified water
throw of 236 meters.
4 5
Design - Manufacturing - Marketing
FIREFIGHTING I SYSTEM
One or two fire pumps installed in the engine room driven
by the main engines with a step-up transmission gear, or
using electric motors. The pump(s) provides water for two
fire monitors and an external water spray system installed for
self protection.
6 7
Design - Manufacturing - Marketing
PUMPS MONITORS Jason has a wide range of monitors which cover all class notations FiFi 1/2, FiFi I, FiFi II & FiFi III.
All monitors are designed for a long service life with low maintenance requirements.
OGF 250X350
The standard pump for FiFi I systems and the most used firewater pump world-
wide for FiFi systems. It is a compact and ultra light single suction radial split
centrifugal pump. Horizontal mounting with end suction or side/bottom suction MM302HJF
bends.
JASON fire fighting monitor series MM300 is a single flow path water/foam monitor
Capacity: 700-1700 m³/h at 1500-2000 rpm. designed for marine and offshore applications. It is a low profile monitor, specially designed
Total head: 110-150 mlc for helideck protection. The monitor is fitted with jet/fog type nozzle suitable for water and
Materials: Casing in Ni-Al-Bronze or Nodular AFFF type of foam. The monitor is designed with two swivels, one for horizontal, and one
Cast Iron for the vertical movement. These are with self-locking worm and wheel type gear, totally
Impeller in Ni-Al- Bronze sealed and greased for life. The monitor operates hydraulically and with electric remote
Shaft in stainless steel control. Materials are in bronze and high grade steel
Weight: 450 kg
Max capacity: 220 m3/h
Weigth: 90 kg
Length of jet: 65 meters (approx.)
OGF 300X400
A larger version of the OGF 250. Single stage, single suction centrifugal pump.
Horizontal OGF 250 mounting with end suction or side/bottom suction bends. MM402HD/HJF-F
Capacity: 1200-2800 m³/h at 1200-1800 rpm. Long and short barrel single flow path monitor with electric/hydraulic remote control.
Total head: 110-160 mlc Fitted with straight jet nozzle (with jet deflector) or jet/fog nozzle for water and foam.
Materials: Casing in Ni-Al-Bronze
or Nodular Cast Iron Max capacity: 450 m³/h
Impeller in Ni-Al- Bronze Weight: 125 kg
Shaft in stainless steel Length of jet: 90 meters (approx)
Weight: 900 kg
MM602HD
Single flow path long barrel water monitor with electric/hydraulic
remote control. Fitted with straight jet nozzle with jet deflector.
8 9
Design - Manufacturing - Marketing
Single flow path monitor with electric/hydraulic remote control. Fitted with variable or fixed
capacity jet/fog type nozzle. Nozzle control accomplished from the monitor’s control panel
which enables adjustment of the jet type from straight stream to fog shape.
The variable flow nozzle is unique in its ability to enable the capacity of the monitor to
be changed while the monitor is in operation. See our web page www.jason.no for more
FIFI INTERGRATED GEARBOX & CLUTCH
information. High quality step-up transmission with built in operated hydraulic clutch for fire pump drive.
Special integrated design with fire pump flanged on to the gear/clutch gives the most compact
Max capacity: 1500/300 m3/h building length. Vertical offset shaft with minium alignment work.
Weight: 320 kg
Length of jet: 140 meters (approx.) Engine speed: 600-1800 rpm
Pump speed: max 2000 rpm
Pump power consumption: max 1300 kW
Standard torque capacity: 7500-16000 Nm
Max pump capacity: 2100 m³/h
10 11
Design - Manufacturing - Marketing
Design and calculation of the water curtain fire fighting systems by Jason Engineering. Documentation to
classification society for approval.
Design of advanced naval type water curtain systems, for ABC protection. (Atomic, Biological, Chemical
protection).
10 liters pr. minute pr. m2 on exposed vertical surface of hull including superstructure, deckhouses, lifeboats and
monitors. System calculation by computer program. No manual adjustment after installation. Various nozzle types
are used depending on surface structure. Each nozzle is individually calculated and marked for specific position.
12 13
Design - Manufacturing - Marketing
CLASSIFICATION REQUIREMENTS
Classification societies have issued rules and regulations
for vessels equipped with large fire fighting systems.
14 15
Design - Manufacturing - Marketing
Developed by
16 17
Design - Manufacturing - Marketing
DSP-TW-1P/2P-H
Height between the sea surface and the manifold Electric power required is 3-4 kw. The pump motor
should be approx. 3m and can easily be adjusted speed is controlled with frequency converter. Pump
up and down by means of two ropes, jagging speed/pressure is remote operated by means of a
wheels and two small hydraulic motor driven small bridge mounted control panel with two push
winches (explosion proof system). buttons and a digital display.
Soft hoses with quick couplings act as dispersant The complete dispersant spray system is remote
supply line from the boom down to the nozzle controlled by means of a control cabinet, shut-
manifold. At the manifold inlet a specially designed off valves with hydraulic actuator and two small
pressure pilot operated check valve is fitted. This hydraulic motor driven winches on each boom in
valve has also an integrated hose swivel coupling order to adjust distance between sea surface and
in order to prevent the supply hoses from twisting. the nozzle manifold.
The dispersant spray nozzles are flat jet type with A small hydraulic power unit with all necessary
spray angle of approx. 45 degrees. The flowrate is control valves is included and should be installed
2.5-5 ltr/min per nozzle in one of the twin manifolds below deck in a safe protected area.
and 10 ltr/min in the other one (at 2 bar inlet
DSP-TW-2P-H pressure). The valve actuators have sensors for indication of
Hydraulic twin boom system with two dispersant pumps open/closed position.
The boom is fitted with “hook-on” type hinges for A portable control panel with flexible cable and
quick and easy erection. plug in connector is included. It has switches for
operation of the two winches and valves plus
Weight of the boom exclude the two small hydraulic indicating light for valve position.
motor driven winches is approx.
60 kg. As an option the system can be supplied with
wireless remote control.
18 19
®
Engineering
Jason Engineering AS
Grønland 76-82
PO Box 2151 Strømsø
3003 Drammen
Norway
Phone: +47 32 20 45 50
Fax: +47 32 20 45 60
jason@jason.no
www.jason.no