Presented by
LUTFI KHOIRUL MIFTAKHUL NIAM– BMDP PLANT 33
90002566
This document is confidential and intended solely for the use and information of the addressee
Project Team
Sponsor
Project Leader
Project Member
C 7 Memeriksa Hasil
Calender of Event
Hari : Sabtu
Waktu : Menyesuaikan
40%
50
11.4 20%
9.21 10.2 8.2 8.1
0 0%
OB HAULER OB LOADER COAL LOADER COAL HAULER SGE
130.8%
112.0%
114%
112%
100.4%
100.1%
105%
106%
105%
104%
103%
99.6%
98.0%
101%
92.0%
86.5%
93%
81.7%
81%
OB HAULER OB LOADER COAL LOADER COAL HAULER SGE
KPI OB Hauler
KPI OB Hauler 84.6
90.0 91% 89% 100%
trending down
80.0
pada periode 88% 80%
70.0
yang sama. 77.3 MTBS Trending
60.0 73.1
Down 60%
50.0
62% 61%
40.0 55% 40%
30.0
20.0 9.6 8.3 9.8 20%
10.0
0.0 0%
*Source: SAP (2018) Oct-18 Nov-18 Dec-18
KPI PLT KDC_2018 *Target MTBS 70 Hours
MTBS MTTR %SM %PA
KPI OB Loader *Target MTBS 80 Hours KPI COAL HAULER *Target MTBS 70 Hours KPI COAL LOADER *Target MTBS 60 Hours
160.0 93% 92% 92% 100% 93%
100 92% 92% 100% 200 100%
140.0 90% 93%
147.8 80% 92
120.0 123.9 80 85 80% 80%
101.6 76 150 60% 161
100.0 57%
67% 60% 60 60% 60%
80.0 60% 65% 100 93 62%
62% 60% 58%
60.0 40% 40 40% 83 40%
46%
40.0 50
9.6 11.0 9.7 20% 20 7.8 8.3 8.2 20% 12 20%
20.0 5.0 10
0.0 0% 0 0% 0 0%
Oct-18 Nov-18 Dec-18 Oct-18 Nov-18 Dec-18 Oct-18 Nov-18 Dec-18
MTBS MTTR %SM %PA MTBS MTTR %SM %PA MTBS MTTR %SM %PA
2 Jumlah Event dengan Durasi B/D Oktober – Desember 2018 PER TYPE
1 Populasi Unit OB Hauler Site Kideco HAULER
777D 777E 785-7 2000 6.078 Hour 7000
6000
9% 1500
B/D Duration
5000
Event B/D
10
50% 1000
4000
41% 3000
56 1.575 Hour
45 500 1.264 Hour 2000
1000
342 Event 779 Event 1.440 Event
0 0
*Source: SAP (2018)
777D 777E 785-7
KPI PLT KDC_2018
Event B/D Duration
Hours
70.3
Hours
50
115 65
40 46.8
43.9 110 113.3
30 60
105 60.7
20 109.4 60.2
55
10 100
0 95 50
October November December October November December October November December
MTBS (Hours) Average Linear (MTBS (Hours)) MTBS (Hours) Average Linear (MTBS (Hours)) MTBS (Hours) Average Linear (MTBS (Hours))
1 ParetoPareto
Problem
Problem
Komponen
HD 785
HD- 7785
Periode
- 7 Periode
Oktober
Oktober
- Desember
- Desember
2018 2018 2 Frekuensi Problem Electric
300 882
882 1000 180 445.47 Hour 500
263
263 160
900
900
140 400
250
250 159 Event
800 120
800 271.09 Hour
300
700 100
200 411 923
923 810 700 80
200 411 810 200
165 163 337 600
155 60
165 163 337 600 85.72 Hour
150 155 337
138 500 40 79.79 Hour
337 258 100
124 45 Event
150 138 500 20 37 Event
124 107
258 556 400 22 Event
0 0
100 107 83
556 207 400
170 230 300 ELEC HARNESS BATTERY WORK LAMP ALTERNATOR
100 83 57
207 94
42 41 230
39 131 257 300
200
50 170 94 38 Event B/D Duration B/D
57
42 131
19 11
257 3 100
200
50 41 39
38
0 0 Sub.Compartment Electric Harness
19 11 3
100 3
0 0 Wiring & Sensor Engine 106
Panel control abnormal 19
Alarm fire supression ON 16
EVENT B/D Duration B/D
Work lamp off 6
EVENT B/D Duration B/D Power Mod abnormal 5
Cant start 5
*Source: SAP (2018) Horn Off 2
ZMC8011R, IW65, IW69
58
58
56
54
Average Event 52x
52
51 50
50
48
46
44
Oktober November Desember
Event B/D Rata-rata
*Frekuensi B/D Electric Harness diambil dari unit HD 785-7 *Source: SAP (2018)
KPI PLT KDC_2018
208, 240, 241, 257, 263, 265, 327, 338, 392, 396
MTTR HD 785 - 7
Menurunkan Frekuensi Breakdown HD 785-7 Karena Problem MTTR (Hours) Average Oct - Dec 2018
Hours
2.50
dengan Modifikasi Sensor common rail Menggunakan
2.00
Grafik Planning Kenaikan MTBS HD 785-7 Setelah Perbaikan Grafik Planning Kenaikan %PA HD 785-7 Setelah
72 Perbaikan
70.4 89.5%
70
88.9%
Kenaikan MTBS = 6.7 Jam 89.0% Kenaikan PA (%) = 1%
68
88.5%
66 87.9%
88.0%
63.7
64 87.5%
62 87.0%
60 86.5%
MTBS Awal (Jam) Planning MTBS Setelah Perbaikan (Jam) PA Awal (%) Planning PA Setelah Perbaikan (%)
INTANGIBLE: * Mencegah tejadinya short circuit pada wiring harness yang mengakibatkan fire case (safety)
* Wujud terimplementasinya kepedulian terhadap electrical unit (Quality)
* Meningkatkan self confidence dari section plant sebagai perencana dan maintenance unit yang baik (Moral)
Unit historical
data
Mengurangi Frekuensi
Workshop or Breakdown pada
Shutdown Pit
Electrical Harness
Operational
Maintenance
Module & JSAP
Tools, Sparepart
Service &
Iprovement
Sumber : SOP_09_003_PLTA; Revisi 3.0 - Pelaksanaan Program Periodic Service dan Backlog
Scope of Project: Berfokus pada breakdown electric harness pada unit HD 785-7 (208, 240, 241, 257, 263, 265, 327, 338, 392, 396)
PP LLA
A N
N ) CHEC K
PPLLAANN DO ACT
1 MAN 2 MATERIAL
: Controllable
Guidance hanya berupa Kerusakan pada isolator clamp
Parameter inspeksi : Uncontrollable
check box wiring harness
belum ada
METHOD 3 MACHINE 4
Root Cause Analysis : Apa saja kemungkinan-kemungkinan penyebab masalah dominannya?
(Keparahan) Severity
No Hypothesis Cause Freq. FxS
MF BY DM DR Total
1 Model desain konektor wiring harness & sensor menyatu di HD785-7 20 5 4 5 4 18 360
PP LLA
A N
N CHEC K
PPLLAANN DO ACT
HC-1 Model desain konektor wiring harness & sensor menyatu di unit HD785-7
PP LLA
A N
N CHEC K
PPLLAANN DO ACT
How
What Why How MoE Who When Where
Much
Pemasangan modifikasi
• Model desain konektor
• Memodifikasi connector common rail fuel connector (Deutsch) Lutfi, Bayu,
wiring harness dan April
Machine pressure sensor, dengan menggunakan pada common rail fuel Dhimas, &
sensor menyatu di unit 2019
connector type (Deutsch) pressure sensor HD Derry
HD 785-7
785-7 dengan 6 unit
• Belum ada tools untuk • Pembuatan tools standar bagi mekanik, Workshop USD $
Pembuatan tools Lutfi, Bayu, April A2B 268.76
pengecekan arus untuk memudahkan pemeriksaan resistensi
harness checker & Masfuin 2019
sesuai prosedur arus pada electrical harness
Method
April-
• Penambahan check Program pengecekan Maskur,
• Pengadaan check sheet program s.d
sheet belum spesifik di berjalan setiap Dhani, &
pengecekan wiring & sensor HD 785-7 Juni
form EFAA pelaksanaan service Lutfi
2018
PPL
LLA
A N DDO CHEC K ACT
P ANN O
Step-1 Step-2 Step-3 Step-4 Step-5 Step-6
Step-8 Step-7 Step-8
Justification Root Cause : Desain di konektor wiring harness komatsu masih menyatu dengan konektor
PP LLA
A N
N CHEC K
PPLLAANN DO ACT
PP LLA
A N
N CHEC K
PPLLAANN DO ACT
BEFORE AFTER
Modifikasi connector common rail fuel pressure sensor berguna untuk menghilangkan troubleshooting yang terjadi pada sensor common rail. Tujuannya
dengan penggantian connector maka bisa diminimalisir adanya enviromental pertambangan masuk kedalam connector yang menyebabkan
disconnection dan memudahkan mekanik dalam mengukur resistensi wiring sensor.
C H ED
C E COKK
P LAN CHHEC CK CHECK A
ACC TT ACT
BEFORE AFTER
Pembuatan tools standar (Harness Checker) berguna membantu pemeriksaan resistensi arus pada electrical harness , mencegah adanya short circuit pada wiring
sensor, dan memudahkan mekanik menjustifikasi kerusakan wiring sensor serta standar penggunaan pengukuran.
C H ED
C E COKK
P LAN CHHEC CK CHECK A
ACC TT ACT
BEFORE
Guidance inspeksi electric hanya berupa check box dan belum spesifik
C H ED
C E COKK
P LAN CHHEC CK CHECK A
ACC TT ACT
AFTER
Efektivitas Improvement
Program penambahan check sheet EFAA menjadi acuan bagi mekanik untuk mengukur resistensi arus wiring sensor apakah komponen elektrik seperti
common rail berada pada performa yang baik, dan juga apakah arus dan tegangan output sesuai dengan standar.
C H ED
C E COKK
P LAN CHHEC CK CHECK A
ACC TT ACT
58
58
56
PPLLA D
DOO CHEC K ACT
ANN
Step-1 Step-2
Step-2 Step-3 Step-4 Step-5 Step-6
Step-6 Step-7
Step-7 Step-8
Current Condition : Bagaimana performance-nya saat ini ?
Monthly %PA Okt - Des 2018 AVG Monthly %PA Apr - Jun 2019 AVG Linear (Monthly %PA)
MTBS HD 785 – 7 SEBELUM PROJECT DIMULAI MTBS HD 785 – 7 SETELAH PROJECT DIMULAI
Peningkatan rata-rata
80
75
MTBS sebesar 6.7 Jam
70 75
Average 63.7 Jam Average 70.4 Jam
65 70
70.3 75.8
60 65 70.2
60.7 65.4
60.2
55 60
October November December April May June
Monthly MTBS Okt - Des 2018 AVG Monthly MTBS Apr - Jun 2019 AVG Linear (Monthly MTBS)
PPLLA D
DOO CHEC K ACT
ANN
Step-1 Step-2
Step-2 Step-3 Step-4 Step-5 Step-6
Step-6 Step-7
Step-7 Step-8
Check Result : Bagaimana performance proyek setelah perbaikan dan bagaimana dampaknya?
C HHEEECCCKKK
C
P LAN DO
D O C HDEOC K CCH
HECK ACT ACT
C HHEEECCCKKK
C
P LAN DO
D O C HDEOC K CCH
HECK ACT ACT
Prosedur
PPI JSAP
C HAEECCCTKK
ACT C
PPLLA
PLANANN P LAN DO C HDEOC K CHECK CHHECK
Step-1 Step-2 Step-3 Step-4 Step-5 Step-6 Step-7 Step-8
Standardization : Standard / sistem control yang dibuat untuk mempertahankan hasil improvement?
Mistake Proofing
C HAEECCCTKK
ACT C
PPLLA
PLANANN P LAN DO C HDEOC K CHECK CHHECK
Step-1 Step-2 Step-3 Step-4 Step-5 Step-6 Step-7 Step-8
Standardization : Apa peluang perbaikan berikutnya? Sertakan analisanya
NEXT IMPROVEMENT
Perbandingan Frekuensi B/D Sebelum Improvement dan Sesudah Improvement
pada Komponen Elektric HD 785-7
300 263
250
200 165 163 155 138 124
150 107
83 86 91 83
100 47 57
28 37 25 32 42 41 37 39
50 18 9 22 19 11
3 2 3 4
0
100
35 45 37
50 15 25 22
8
0
ELEC HARNESS BATTERY WORK LAMP ALTERNATOR
NEXT IMPROVEMENT
Melakukan program modifikasi konektor Sensor NE & Sensor G, kemudian melanjutkan modifikasi sensor pressure common rail di HD 785-7 dan PC 2000
C HAEECCCTKK
ACT C
PPLLA
PLANANN P LAN DO C HDEOC K CHECK CHHECK
Step-1 Step-2 Step-3 Step-4 Step-5 Step-6 Step-7 Step-8