DC Load Flow and


Short-Circuit Analyses

Perform load flow and short-circuit


analyses on your DC networks
Ensuring that the DC DC Modeling The DC network can be The voltage and current
connected to the AC system distortion resulting from the
devices, typically found The CYME software supports
through a battery charger or a connection of the charger and/or
the modeling of dc auxiliary
in industrial systems, are power systems (loss of ac
UPS. Load flow and short-circuit the UPS to the AC network can
working safely and within analyses can be executed on be studied with the Harmonic
power) and of industrial
the DC network or on the Analysis module.
parameters under various installations with dc equipment
entire system including the AC
and processes. The harmonic content can be
operating conditions is a network.
entered as per the equipment
concern for power quality in The CYME Equipment Library
manufacturer data sheets.
includes DC equipment such
lower voltage systems. as station batteries, chargers,
Uninterruptable Power Supplies
The DC Load Flow and (UPS) and DC/DC converters.
Short-Circuit Analysis In addition, DC versions of
modules of the CYME the following components are
software enhance the included in the library: cables,
impedance branches, protective
capabilities of the software devices, loads and machines.
to execute simulations on The user can build any DC
DC back-up systems and network with all the necessary
network components.
safe supplies, independently
or as connected to the AC
power system.
DC Load Flow DC Short-Circuit Analysis
The DC Short-Circuit Analysis
DC Load Flow Analysis
The DC Load Flow Analysis
module is dedicated to module supports the steady-
and Short- calculating fault levels in DC
networks and systems.
state analysis of the any DC
systems under various operating
conditions.
Circuit Analyses • Fault analysis on all network
buses and nodes The solution algorithm is the
full Newton Raphson with or
• Fault analysis at user defined
without constraints utilizing
location
sparse matrix/vector methods.
Perform load flow and short- • System-wide fault current and
circuit analyses on your DC Features of the DC Load Flow
voltage profiles
Analysis include:
networks • Automated sliding fault option • Embedded maximum output
on DC cables
current, reverse power flow
• Option to include or not detection and control
contributions from DC • Automatic update of the
equipment
loading of chargers and UPSs
• Machine current contribution on the AC system
reports. • Customer load model library
• Pre-fault nominal or DC load manager for any type including
flow voltage profiles constant power, current,
impedance, composite and
• Fault current security factor voltage sensitivity exponent
for minimum and maximum model
fault studies
• Load and motor scaling factors
• Five limit categories for
nominal, planning, emergency
or any user defined loading
criteria
• Abnormal conditions color
coding on the network
one-line diagram as per user-
defined criteria.

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
© 2017 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 023 EN All other trademarks are property
April 2017 of their respective owners.

Anda mungkin juga menyukai