Introduction
The FireFinder XLS PMI-2 person machine interface uses USB-USB communication between the
PMI-2 and the computer with the installed Zeus Tool. In order to use this communication protocol,
the PMI-2 and the computer must be connected with the USB A-USB B cable. In addition, special
Windows drivers (for Windows XP and Windows 7) must be installed on the USB port(s) of the
computer that will be used to connect to the PMI-2. The installation procedure is different for
Windows XP and Windows 7. Both procedures will be described in turn.
The USB drivers for FireFinder XLS PMI-2 are not installed during the installation of the Zeus Tool.
After the Zeus Tool has been successfully installed on your computer, connect the computer to the
PMI-2 with the supplied USB-USB cable to install the special drivers for the USB port(s).
Installation
Windows XP Installation
When Windows XP is the operating system on your computer, the FireFinder XLS driver must be
installed on every USB port on your computer that will be used to communicate with the
FireFinder XLS PMI-2 panel. If you always use the same USB port on your computer to
communicate with the PMI-2 panel, you don’t need to install the FireFinder XLS driver on
additional USB ports.
The installation procedure for the first FireFinder XLS USB driver is different from the installation
procedure for subsequent USB ports on the same computer. While the installation for subsequent
ports is simpler, it can only be done after the first USB port on the computer has had the
FireFinder XLS USB driver installed. If you are using a computer where you do not know if the
FireFinder XLS USB driver is installed, use the procedure for installing the first FireFinder XLS
driver.
The wizard then asks for the “Hardware Type” as shown in Figure 3. Select “Ports” and press the
“Next” button.
The wizard next asks you to select the device driver you want to install for this hardware as shown
in Figure 4. Press the “Have Disk…” button.
The wizard will find the device driver “FireFinder XLS” in the directory where the FireFinderXLS
program files are located. Select “FireFinder XLS” as shown in Figure 6. Note that the warning
message “This driver is not digitally signed!” is displayed on the lower part of the page. Ignore this
message and press the “Next” button.
When the wizard has successfully completed installing the software for the FireFinderXLS driver, a
screen similar to Figure 7 will display. Communication from the Zeus Tool to the FireFinder XLS
PMI-2 panel will now be possible.
The hardware wizard displays a dialog shown in Figure 9 with the warning that the FireFinder XLS
driver “has not passed Windows Logo testing to verify its compatibility with Windows XP.” Press
the “Continue Anyway” button.
As Windows installs the FireFinderXLS driver, a screen similar to Figure 10 will display the
progress.
Figure 11: FireFinder XLS Device Driver Successfully Installed on Subsequent USB Port
If the installation was not successful for the second or subsequent port, try again using the
instructions for installing the first Windows XP USB port.
Windows 7 Installation
Begin the Windows 7 FireFinder XLS USB-USB driver installation by connecting one end of the USB-
USB cable to the computer with the Zeus Tool installed and the other end to the FireFinder XLS
PMI-2 panel. Windows will display the message “Device driver software was not successfully
installed” shown in Figure 12.
Figure 12: Device Driver Software Was Not Successfully Installed Screen
You will need to start the Device Manager tool in order to install the driver. Open the “Control
Panel” and in the Control Panel window, select “System and Security.” (Refer to Figure 13.)
Figure 14: Control Panel > System and Security Window Showing Administrative Tools
In the “Administrative Tools” window, open “Computer Management.” (Refer to Figure 15.)
In the “Computer Management” window, select “Device Manager” from the tree in the window on
the left side of the screen. In the tree on the right side of the window, select other devices.
There are two possible variants for installing the “FireFinder XLS” driver. These variants depend on
the following criteria:
When Windows 7 is the operating system, it is not necessary to install the FireFinder XLS driver on
every USB port. When the FireFinder XLS driver is installed on one USB port of a computer in a
Windows 7 system, the installation is good for all of the computer’s USB ports.
Press the “Update Driver” button that displays in the Gadget Serial v2.4 Properties screen as shown
in Figure 16.
Then select the “Browse my computer for driver software” option shown in Figure 17.
Click on the “Browse” button as shown in Figure 18 to search for the directory where the Zeus Tool
is installed on your computer. The default program folder is C:\Program Files\Siemens FireFinder
XLS\Zeus 10.0. The location shown in Figure 18 is D:\FireFinderXLS. After selecting the directory
where the Zeus Tool is installed on your computer, press the “Next” button.
Windows will begin installing the driver software as indicated in Figure 20.
When the FireFinder XLS driver has been successfully installed as shown in Figure 21, press the
“Close” button. Communication between the Zeus Tool and the panel using the USB ports is now
possible.
The “Welcome to the Add Hardware Wizard” will display as shown in Figure 24. Press the “Next”
button at the bottom of the page to continue.
Use the scroll bar to find and select the “Ports” hardware type as shown in Figure 26. Then press
the “Next” button.
Click on the “Have Disk” button when the screen asks what device driver you want to install as
shown in Figure 27.
The hardware wizard will find the device driver in the same location that the FireFinder XLS
program files are stored. (Refer to Figure 29.) Select “FireFinder XLS.”
Note that a message displays at the bottom of Figure 29 warning that “This driver is not digitally
signed!” Ignore the message and press the “Next” button.
Confirm the installation of the FireFinder XLS driver by pressing the “Next” button as shown in
Figure 30.
Windows will install the “FireFinder XLS” driver software. After the driver has been successfully
installed, communication between the Zeus Tool and the panel using the USB ports is possible.
After the FireFinder XLS driver has been installed, the “Device Manager” will display “FireFinder
XLS” between the Communications and Printer Ports, as shown in Figure 32. There will be a
number assigned to the port in the Zeus Tool.
Important Notes:
1. The FireFinder XLS port is activated and visible to the Zeus Tool and the Device Manager
only when the FireFinder XLS PMI-2 panel is connected to the computer. When the
computer is disconnected from the panel, the port disappears from the list of ports
available on your computer.
When you wish to determine which port number is connected to the panel:
Disconnect the panel from the computer.
Look on the list of available ports in the Zeus Tool.
Connect your panel to the computer again.
The new port where your panel is connected will appear in the Device Manager
“Ports” list.
2. Every USB port on a Windows computer will have its own port number. This port number
will not change. It will remain the same every time that the FireFinder XLS PMI-2 panel is
The best practice is to use the same USB port every time you connect to the FireFinder XLS
PMI-2 panel. You can store this port number in the Zeus Tool using the Tools>Options
menu.