Anda di halaman 1dari 4

A Technical Paper On

AGRO SYSTEM
Karthik R Rao, Harshitha, Deepthi D’Souza and Anudeep S
Computer Science and Engineering
Nitte Mahalinga Adyanthaya Memorial Institute of Technology
Nitte-574110
Udupi District
karthikrao@gmail.com
harshitha@yahoo.com
deepthidzouza@yahoo.com
anudeep000@gmail.com

Abstract— Agro system is a system designed and developed for around the field. The systems that you can
monitoring ones piece of field from a remote place with a
personal computer . This system is made up of many subsystems. control include: Lighting, Appliances, and
It includes small systems like weather monitoring system, power
power , switching ON/OFF of pump or water level
control system and camera control system. These subsystems are
integrated and interfaced with a personal computer as the server. in well/field can be detected and appropriate actions
The server connected with these system forms the agro system.
can be performed accordingly. Security and
monitoring systems etc.
I. INTRODUCTION
The problem we have solved. The need for remote
monitoring of ones beloved agriculture field. This method This central controller can be accessed and controlled
keeps tracks of the activities or changes taking place in the through interfaces like keypad, wired or wireless touch-
field and helps user to take suitable action. screens (with/without video), universal remotes, mobile
devices. Field automation provides a more convenient &
Field Automation is the process of automatically elegant atmosphere for the family to control and manage
performing everyday functions around the agriculture the field. Every one in the family experiences the comfort
field to save you time, energy, money and at the same of automation with added convenience through
time offering improved security. integrated control of scheduled common lifestyle
activities performed everyday. It creates reliable and
coordinated controls to operate field devices
automatically for simplifying operations.
The automation is performed by a central controller.
This can be either a standalone unit or a piece of
software on a PC. The controller can carry out a number Field automation provides you pro-active field security
of functions: so that you can look in on your field remotely from
anywhere in the world, or that your server will phone you
if it finds anything suspicious, or that a fire will alert your
server to wake you, In other words it integrates your
1.2 Functions
alarm system with other field systems for a response to
intrusion that meets your needs of enhanced Safety.
Send signals to switch lights and appliances on or off.
Open and close contacts to operate high and low
voltage devices. Schedule and initiate events, such as
watering the field Issue and accept information with
other systems, i.e. sensors etc.
• Field automation is anything that gives you
remote or automatic control of things in &
Security who plans to develop products that will take advantage
of micro controllers.
There are real benefits to having your automation Level Converter MAX 232
controller and security system combined in one unit. You
have the advantage of infra red detectors from the alarm Introduction
system being available to perform/trigger automation
tasks. You can also benefit from the alarm system
knowing whether you’re at field or not (i.e. whether the The MAX232 is an integrated circuit that converts
alarm is set or not). This can give numerous benefits, for signals from an RS-232 serial port to signals suitable for
example we could set the system so that if no use in TTL compatible digital logic circuits. The MAX232
movement is detected in the field for a given period, say is a dual driver/receiver and typically converts the RX,
16 hours, then it rings a mobile telephone and conveys a TX, CTS and RTS signals.
message to the recipient.
The drivers provide RS-232 voltage level outputs
Needless to say, if the alarm system forms the basis of (approx. ±7.5V) from a single +5V supply via on-chip
our automation system, then it needs to be of a charge pumps and external capacitors. This makes it
particularly high standard, able to expand to suit all useful for implementing RS-232 in devices that
requirements. You should be able to connect smoke otherwise do not need any voltages outside the 0V to
detectors in to the system and when triggered, +5V range, as power supply design does not need to be
automatically dialing the fire brigade with a pre recorded made more complicated just for driving the RS-232 in
message. this case.

The receivers reduce RS-232 inputs (which may be as


high as ±25V), to standard 5V TTL levels. These
receivers have a typical threshold of 1.3V, and a typical
Field Automation hysteresis of 0.5V.

Server The later MAX232A is backwards compatible with the


original MAX232 but may operate at higher baud rates
and can use smaller external capacitors – 0.1μF in place
of the 1.0μF capacitors used with the original device.
Central
Controller
MAX232 integrated circuit
Remote PC
Internet Medium The MAX232 from Maxim was the first IC which in one
package contains the necessary drivers (two) and
receivers (also two), to adapt the RS-232 signal voltage
levels to TTL logic. It became popular, because it just
Field Appliances needs one voltage (+5V) and generates the necessary
RS-232 voltage levels (approx. -10V and +10V)
internally. This greatly simplified the design of circuitry.
Circuitry designers no longer need to design and build a
power supply with three voltages (e.g. -12V, +5V, and
6.1 Microcontroller AT8051 +12V), but could just provide one +5V power supply,
e.g. with the help of a simple 78x05 voltage converter.
The Intel AT8051 is a Harvard architecture, single chip
micro controller which was developed by Intel for use in It should be noted that the MAX232(A) is just a
embedded systems. . driver/receiver. It does not generate the necessary RS-
232 sequence of marks and spaces with the right timing,
The AT80c51 is one of the most popular micro it does not decode the RS-232 signal, it does not
controllers in use today. Many derivative micro provide a serial/parallel conversion. All it does is to
controllers have since been developed that are based convert signal voltage levels. Generating serial data
on--and compatible with--the AT8051. Thus, the ability with the right timing and decoding serial data has to be
to program an AT8051 is an important skill for anyone done by additional circuitry, Logic Signal Voltage
Serial RS-232 (V.24) communication works with SOLUTION
voltages (between -15V ... -3V are used to transmit a Why our solution is worth considering and why it is
binary '1' and +3V ... +15V to transmit a binary '0') which effective in some ways that others are not because in this
are not compatible with today's computer logic voltages. world of automation, in some or the other forms of system
On the other hand, classic TTL computer logic operates make their way in replacing man power and thus making life
between 0V ... +5V (roughly 0V ... +0.8V referred to as easy. Even in the field of agriculture automation places a
low for binary '0', +2V ... +5V for high binary '1' ). Modern major role. Hence an attempt to automate and monitor
low-power logic operates in the range of 0V ... +3.3V or agriculture fields in this paper.
even lower.

So, the maximum RS-232 signal levels are far too high
for today's computer logic electronics, and the negative II. IMPLEMENTATION
RS-232 voltage can't be grokked at all by the computer The implementation part can be roughly divided in to two
logic. Therefore, to receive serial data from an RS-232 parts:
interface the voltage has to be reduced, and the 0 and 1 • Hardware section
voltage levels inverted. In the other direction (sending • Software section
data from some logic over RS-232) the low logic voltage
has to be "bumped up", and a negative voltage has to be The hardware section consists of circuits with web
generated, too. thermometer, web camera and a motor as a power control
system. All these hardware components are connected to
RS-232 TTL Logic microcontroller which inturn connected to serial port or
----------------------------------------------- RS232 port of the personal computer through a MAX232.
-15V ... -3V <-> +2V ... +5V <-> 1 the circuit diagram is as shown below:
+3V ... +15V <-> 0V ... +0.8V <-> 0

All this can be done with conventional analog


electronics, e.g. a particular power supply and a couple
of transistors or the once popular 1488 (transmitter) and
1489 (receiver) ICs.
I.
In the software section a program controlling the serial
port is designed in C/C++. Through this program
respective signals are handled and sent to the
microcontroller through RS232 serial port. The program is
invoked by the client side machine and the user defined
actions is performed by the server side machine. At the
client side a very interactive user interface is designed
using the HTML,AJAX,PHP and javascript languages.
III. CONCLUSION AND FUTURE WORKS There are future plans like controlling through mobile
The system is focussed mainly on landlords or estate phones so that the small farmers are also benefited by this
owners who owns vast area of lands and fields spread system.
across different parts of the world.
This system may be less helpful and not so worthy for
IV. REFERENCES
small farmers as initial investments may be high.

www.nith.ac.in/icacc10/ieee_formatting.doc